CLEAN STEAM PRODUCTS. CoMBo TEMPERATURE CONTROL PEAK CONDENSATE LOADS
|
|
|
- Charity Bruce
- 9 years ago
- Views:
Transcription
1 Steam-in-place sterilization (SIP) systems for vessels and associated piping are highly engineered systems. There are several different arrangements used by the Biotech Industry to purge air, heat-up the vessel and maintain a steam temperature of 121ºC for a minimum of 15 minutes. Typically clean steam is introduced to the top of the vessel and exits through feed lines, vent lines and drain lines. Air, steam and condensate typically flow through a three-way valve (Piping Diagram) located at the remote end of each pipeline. During this heat up stage the peak condensate loads shown in the table below are encountered. When the vessel is heated to 95ºC, the air is considered to be sufficiently purged and the three-way valve switches over to the Nicholson Model CME-A CoMBo Steam Trap. Once the temperature reaches the desired 121ºC, tank heat losses are minimal and the steady condensate maintenance load shown in the table below are maintained. CLEAN STEAM PRODUCTS Thermostatic steam traps operate based on the difference in temperature of the condensate and the steam. The Nicholson Model CDS 204 steam trap, with the B bellows is the most sensitive in the market 1 C (2-3ºF) sub-cool. This means that SIP system temperatures can be set lower and control limits are tighter as shown in the graph below. This lower temperature reduces rouging and extends the life of components. CoMBo TEMPERATURE CONTROL 1 PEAK CONDENSATE LOADS Tank Peak Condensate Condensate Volume heat-up Load Maintenance (Liter) lb/hr (kg/hr) Load lb/hr (kg/hr) (1134) 27 (12) (567) 14 (6) (181) 7 (3) (136) 5 (2) (91) 3 (1.4) (45) 2 (.9) (14) 1 (.4) (7) 0.5 (.2) The high capacity of the CME-A makes it an excellent choice when a 3-way valve is not utilized. The Nicholson model CME-A can be used to pass Clean-In-Place Return (CIPR) as shown in the CME- A Piping Diagram. The Nicholson CME-A can pass 3608 #/Hr (1636 kg/hr) of 80ºC condensate at 20 psi (1.4 bar) which exceeds the design peak condensate load of 2500#/Hr (1134 kg/hr) for all tank volumes shown above. The requirement to use multiple steam traps or a 3-way valve on the bottom of a sterilization tank depends on the time required to purge the air and condensate during the air purge cycle. The ball valve allows a faster purging of the condensate, but increases the sterilization time since it slows pressure build-up if steam is vented. Extensive testing with the CME-A CoMBo has shown that the condensate backup varies with the steam pressure and condensate load as shown in the chart below. High sensitivity in combination with the industry s highest capacity, means a minimum condensate leg is required above the trap to achieve the required cooling. The CoMBo maintains condensate below the temperature thermocouple for loads ranging from 1 to 27 lb/hr ( kg/hr) which are encountered during SIP maintenance of vessels ranging from 20 liters to 40,000 liters respectively. CoMBo BACKUP TESTING PIPING DIAGRAMS ARRANGEMENT #1 ARRANGEMENT #2
2 2 APPLICATIONS CIP/SIP System Condensate Drainage Sterilization of Process Vessels Culinary Steam Humidifiers WFI System Sterilization Fermenter Sterilization MODELS CME-A - Direct Immersion RTD CME-W25 - Well Installation RTD OPTIONS CME-A CONDENSATE MEASURING ELBOW MP - Mechanical Polish to 10 µ in. Ra EP - Electropolish SLR - SLR Orifice Tef-Steel, PTFE, Teflon, E.P.D.M., USP Class VI & other gasket materials also available Horizontal or vertical inlet flow Horizontal or vertical well CME-A Direct immersion hygienic clamp RTD supplied by customer CME-W25 Well installation NPT RTD supplied by cutomer APPLICABLE CODES ASME BPE NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required. OPERATION CME-W25 VERTICAL WELL Thermal actuator is filled at its free length with a liquid having a lower boiling point than water. On start-up, valve is normally open to discharge air, non-condensibles and condensate. When steam enters trap, thermal actuator fill vaporizes to a pressure higher than line pressure. This forces valve into seat orifice to prevent any further flow. CoMBo CONDENSATE MEASURING ELBOW THERMOSTATIC STEAM TRAP Pressures to 40 PSIG (2.7 barg) Temperatures to 292 F (144 C) SENSITIVITY The B bellows has been designed to achieve a 1ºC (2-3 F) sub-cool. This is the most sensitive trap in the market place today. It maintains backup of condensate below 6" (150mm) for SIP maintenance of vessels sized 40,000 liters and below. HIGH CAPACITY These traps have 30-50% higher capacities than any competitor. This means they can often handle the peak condensate load encountered during vessel heat-up without requiring bypass through a three-way valve. LONG LIFE The one single moving part is a multi-plate bellows made of 316L Stainless Steel. The bellows have been tested to exceed 40,000,000 cycles. UNIVERSAL INDUSTRY STANDARD GASKET One gasket fits all Nicholson Sanitary Steam Traps. White Viton food grade gasket offers superior performance for higher pressure steam applications. WATER HAMMER PROTECTION Impingement plate protects the bellows and valve from hydraulic shock. This design allows self-centering alignment for superior valve-to-orifice sealing. MODULATING FLOW DYNAMICS Nicholson Sanitary Steam Traps use conical valves for better flow dynamics, consistent system temperature and pressure and longer life than ball bearing valves. SELF DRAINING Completely free draining with the steepest interior surfaces prevents puddling. AIR VENTING Thermostatic Bellows allow for superior and faster system start up. SLR OPTION Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. COST EFFICIENT Eliminates clamp on top of CDS SIMPLIFIED VALIDATION Only one unit to validate, complete with all MTRs. ORDERING CODE Well Model Dash Well Depth Example: C M E - A Position: MODEL Position 1-3 CME = Condensate Measuring Elbow DASH Position 4 WELL Position 5 A = No Well W = Well WELL DEPTH Position 6 & 7 25 = 2.5" No Well = Leave Blank As condensate collects, it takes heat from the actuator, lowering internal pressure. Line pressure will then compress thermal actuator to open valve and discharge condensate. Valve opening automatically adjusts to load conditions from minimum on very light loads to full lift at maximum load. Sensitivity of bellows maintains condensate below thermal probe connection.
3 CoMBo CONDENSATE MEASURING ELBOW THERMOSTATIC STEAM TRAP SPECIFICATION Steam trap shall be of balanced pressure design with 316L welded bellows capable of releasing condensate within 1ºC (2-3ºF) of saturated pressure. All other interior wetted components shall be of 316L stainless. It shall have interior body finish of at least 20 µ in. (0.5 µm) Ra and exterior body finish of at least 32 µ in. (0.75µm) Ra. Trap shall utilize hygienic body clamp allowing disassembly for inspection or cleaning and be entirely self draining. Trap end connections shall be standard hygienic clamp. Thermostatic actuator shall employ a conical valve lapped to the seat. Traps shall have SLR orifice where drainage at saturated temperatures is required. Traps shall be guaranteed against defects for 3 years. Trap shall maintain condensate below the temperature thermocouple for loads ranging from 1 to 27 lb/hr (0.4 to12 kg/hr) which are encountered during SIP maintenance of vessels ranging from 20 liters to 40,000 liters respectively. 3 MAXIMUM OPERATING CONDITIONS PMO: Max. Operating Pressure 40 psig (2.7 barg) TMO: Max. Operating Temperature 292 F (144 C) PMA: Max. Allowable Pressure 150 psig (10.3 barg) TMA: Max. Allowable Temperature 366 F (186 C) MATERIALS OF CONSTRUCTION Part # Part Name Material 1 Condensate Elbow...ASME BPE 316L 2 Actuator Nut...316L 3 Body Gasket...Viton B Bellows...316L 5 Body Outlet...A L 6 Valve...316L 7 Body Clamp Impingement Plate...316L 9 Well...316L 10 Well Gasket...Viton Well Clamp BODY SURFACE FINISH Internal <20 µ in. (0.5 µm) Ra SFCI.External <32 µ in. (0.75 µm) Ra. Optional mechanical polishing to 10 µ in. (0.25 µm) Ra and/or electropolish SFC4 CME-A Direct Immersion RTD 2.3 lbs 2-1/2 2-3/4 [69.9] CME-W25 Vertical Flow 2.8 lbs GASKET APPROVALS FDA CFR Title 21 Part 177, USDA, USP Class VI, 3A Sanitary Standard, NSF SERVICE NOTES Trap is supplied with the -B Bellows to maintain condensate below the thermal probe. CME-W25 is designed to be self-draining with a horizontal inlet and vertical downward discharge. MAXIMUM CAPACITY - lbs/hr (kg/hr) 2-1/2 Differential PSIG (bar) Condensate Orifice Temperature Inches (0.34) (0.7) (1.4) (2.1) (2.8) (3.4) (4.1) (4.8) (5.5) (6.2) (6.9) 80 C Water 5 C Subcool 1 C Subcool (818) (1157) (1636) (2004) (2281) (2587) (2794) (3018) (3226) (3422) (3659) 5/ (689) (758) (848) (965) (1044) (1138) (1230) (1278) (1336) (1402) (1433) (309) (351) (390) (442) (503) (532) (554) (585) (611) (647) (659) CME-W25 Horizontal Flow Connections: 3/4" Hygienic Clamp
4 4 APPLICATIONS CIP/SIP System Condensate Drainage Sterilization of Process Vessels Culinary Steam Humidifiers WFI System Sterilization Fermenter Sterilization OPTIONS MP - Mechanical Polish to 10 µ in. (0.25 µm) Ra EP - Electropolish SLR - SLR Orifice Tef-Steel, PTFE, Teflon, E.P.D.M., USP Class VI & other gasket materials available -B Bellows for low subcool 6" Condensate Leg (CME-W25, CME-A) APPLICABLE CODES ASME BPE Canadian Registration # 0E OPERATION Thermal actuator is filled at its free length with a liquid having a lower boiling point than water. On start-up, valve is normally open to discharge air, non-condensibles and condensate. When steam enters trap, thermal actuator fill vaporizes to a pressure higher than line pressure. This forces CDS SANITARY THERMOSTATIC STEAM TRAPS Pressures to 100 PSIG (6.9 barg) Temperatures to 338 F (170 C) Steepest Interior Surfaces Designed to completely drain without puddling. Stainless Steel Body Body Material is 316L Stainless Steel with 20 µ in. (0.5 µm) Ra internal finish and 32 µ in. (0.75 µm) Ra external finish. Available with mechanical polishing to 10 µ in. (0.25 µm) Ra and/or electropolish. Self centering Valve Leak tight shut off. Assembly of actuator and valve to impingement plate allows the valve to self align with center of the orifice. Temperature Sensitive Actuator One moving part. 316L Stainless Steel, fail open, welded actuator for maximum corrosion, thermal and hydraulic shock resistance. Directional Discharge Erosion prevented by directing discharge to center of piping. Maintenance Can be easily removed and disassembled for sterilization and/or repair. Three Year Guarantee Guaranteed for three years against defects in material or workmanship. Industry Standard Food Grade Gasket White Viton food grade gasket offers superior performance for higher pressure steam applications. Large Orifice Selection Broad selection of orifice sizes provide greatest sizing and selection flexibility. Superior Air Handling Best air handling capability provides for fast startup. Unique SLR Orifice OptionSpecify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. Bar Stock Connectiion fittings are not welded onto inlet and outlet pieces. MODELS CDS202 Low capacity CDS203 Medium capacity CDS204 High capacity NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required. valve into seat orifice to prevent any further flow. As condensate collects, it takes heat from the actuator, lowering internal pressure. Line pressure will then compress thermal actuator to open valve and discharge condensate. Valve opening automatically adjusts to load conditions from minimum on very light loads to full lift at maximum load.
5 CDS SANITARY THERMOSTATIC STEAM TRAPS C 5 SPECIFICATION Steam trap shall be of balanced pressure design with 316L welded bellows capable of releasing condensate within 1ºC (2-3ºF) or 5ºC (10 F) of saturated pressure. All other interior wetted components shall be of 316L stainless. It shall have interior body finish of at least 20 µ in. (0.5 µm) Ra and exterior body finish of at least 32 µ in. (0.75 µm) Ra. Trap shall utilize hygienic body clamp allowing disassembly for inspection or cleaning and be entirely self draining when installed in vertical configuration. Trap end connections shall be standard hygienic clamp. Thermostatic actuator shall employ a conical valve lapped to the seat. A minimum of three orifices shall be available.traps shall have SLR orifice where drainage at saturated temperatures is required. Traps shall be guaranteed against defects for 3 years. MAXIMUM OPERATING CONDITIONS PMO: Max. Operating Pressure 100 psig (6.9 barg) TMO: Max. Operating Temperature 338 F (170 C) PMA: Max. Allowable Pressure 150 psig (10.3 barg) TMA: Max. Allowable Temperature 366 F (186 C) C A B BODY SURFACE FINISH Internal <20 µ in. (0.5 µm) Ra SFCI.External <32 µ in. (0.75 µm) Ra. Optional mechanical polishing to 10 µ in. (0.25 µm) Ra and/or electropolish SFC4 GASKET APPROVALS FDA CFR Title 21 Part 177, USDA, USP Class VI, 3A Sanitary Standard, NSF SERVICE NOTES Trap is designed to be self draining for vertical installation (discharge down) 1 /2" - 3 /4" service trap should be installed with 3 /4" inlet gasket. 1" /2" service trap should be installed with 1 1 /2" inlet gasket. SLR ORIFICE OPTION Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. POLISHING PROCEDURE All surface finishes are achieved without the use of additional buffing, compounds or grit. -B BELLOWS 1ºC (2-3ºF) subcool for sensitive applications under 40 psi (2.7 barg) 4 5 Connections: 1/2" 1 1 2" Hygienic Clamp DIMENSIONS inches (mm) and WEIGHTS pounds (kg) Service A B C Weight and and (63) (67) (25) (.8) (63) (67) (50) (1.0) MATERIALS OF CONSTRUCTION Item Part Name Material 1 Body Inlet 316L A276 2 Actuator Nut 316L 3 Gasket Viton Actuator 316L 5 Body Outlet 316L A276 6 Valve 316L 7 Clamp (not shown) Impingement Plate 316L Maximum Capacity lbs/hr 10 F Below Saturation (Kg/hr 5 C Below Saturation) Differential PSIG (bar) Trap Orifice Inches (0.34) (0.7) (1.4) (2.1) (2.8) (3.4) (4.2) (4.9) (5.6) (6.2) (6.9) CDS 202 5/32 (132) (186) (264) (326) (377) (417) (454) (488) (513) (533) (547) CDS 203 1/4 CDS 204 5/16 For Kg/Hr Multiply by (249) (374) (549) (678) (794) (896) (987) (1066) (1145) (1202) (1281) (689) (758) (848) (965) (1044) (1138) (1230) (1278) (1336) (1402) (1433) NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required.
6 6 APPLICATIONS CIP/SIP System Condensate Drainage Sterilization of Process Vessels Culinary Steam Humidifiers WFI System Sterilization Fermenter Sterilization OPTIONS MP - Mechanical Polish to 10 µ in. (0.25 µm) Ra EP - Electropolish SLR - SLR Orifice Tef-Steel, PTFE, Teflon, E.P.D.M., and other gasket materials available APPLICABLE CODES ASME BPE Canadian Registration # 0E0591.9C CDH SANITARY THERMOSTATIC STEAM TRAPS Pressures To 100 PSIG (6.9 barg) Temperatures to 338 F (170 C) Universally Configurable Horizontal connections from any direction on standard model; AI and AO models feature one multi-directional horizontal and one vertical connection. Steepest Interior Surfaces Designed to completely drain without puddling, even in significantly sloped lines. Stainless Steel Body Body Material is 316L Stainless Steel with 20 µ in. (0.5 µm) Ra internal finish and 32 µ in. (0.75 µm) Ra external finish. Available with mechanical polishing to 10 µ in. (0.25 µm) Ra and/or electropolish. Self centering Valve Leak tight shut off. Assembly of actuator and valve to impingement plate allows the valve to self align with center of the orifice. Temperature Sensitive Actuator One moving part. 316L Stainless Steel, fail open, welded actuator for maximum corrosion, thermal and hydraulic shock resistance. One Size Suits Most Services Universal hygienic clamp fits both 1/2" and 3/4" piping. Maintenance Can be easily removed and disassembled for sterilization and/or repair. Four Year Guarantee Guaranteed for four years against defects in material or workmanship. Inventory Standard Food Grade Gasket White Viton food grade gasket offers superior performance for higher pressure steam applications. Superior Air Handling Best air handling capability provides for fast startup. Unique SLR Orifice Option Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. Bar Stock Connectiion fittings are not welded onto inlet and outlet pieces. MODELS CDH-AI-AO Horizontal inlet and outlet CDH-AI Horizontal inlet, vertical outlet CDH-AO Vertical inlet, horizontal outlet OPERATION Thermal actuator is filled at its free length with a liquid having a lower boiling point than water. On start-up, valve is normally open to discharge air, non-condensibles and condensate. When steam enters trap, thermal actuator fill vaporizes to a pressure higher than line pressure. This forces NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required. valve into seat orifice to prevent any further flow. As condensate collects, it takes heat from the actuator, lowering internal pressure. Line pressure will then compress thermal actuator to open valve and discharge condensate. Valve opening automatically adjusts to load conditions from minimum on very light loads to full lift at maximum load.
7 CDH SANITARY THERMOSTATIC STEAM TRAPS SPECIFICATION Steam trap shall be of balanced pressure design with 316L welded bellows capable of releasing condensate within 5ºC (10 F) of saturated pressure. All other interior wetted components shall be of 316L stainless. It shall have interior body finish of at least 20 µ in. (0.5 µm) Ra and exterior body finish of at least 32 µ in. (0.75 µm) Ra. Trap shall utilize hygienic body clamp allowing disassembly for inspection or cleaning and be entirely self draining in horizontal or angle piping configuration. Trap end connections shall be standard hygienic clamp. Thermostatic actuator shall employ a conical valve lapped to the seat. Traps shall have SLR orifice where drainage at saturated temperatures is required. Traps shall be guaranteed against defects for four years. MAXIMUM OPERATING CONDITIONS PMO: Max. Operating Pressure 100 psig (6.9 barg) TMO: Max. Operating Temperature 338 F (170 C) PMA: Max. Allowable Pressure 150 psig (10.3 barg) TMA: Max. Allowable Temperature 366 F (186 C) MATERIALS OF CONSTRUCTION Part # Part Name Material 1 Body Inlet...A L 2 Clamp Gasket...Viton Body Outlet...A L 5 Actuator Nut...316L 6 Impingement Plate...316L 7 Actuator...316L SS 8 Valve...316L CONNECTION Sanitary Ferrule accommodates 1/2" and 3/4" service BODY SURFACE FINISH: Internal <20 µ in. (0.5 µm) Ra SFCI.External <32 µ in. (0.75 µm) Ra. Optional mechanical polishing to 10 µ in. (0.25 µm) Ra and/or electropolish SFC4 GASKET APPROVALS: FDA, USDA, USP Class VI, 3A Sanitary Standard, NSF 3" 4" " 3" CDH-AI-AO 3.9 LB.(1.8 kg) 1 1 2" 3 1 4" 2 3 4" 3" CDH-AI 2.6 LB. (1.2 kg) 3" 2 3 4" 3 1 4" 1 1 2" CDH-AO 3.1 LB. (1.4 kg) Connections: 1/2/3/4" Hygienic Clamp 7 SLR ORIFICE OPTION Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. POLISHING PROCEDURE All surface finishes are achieved without the use of additional buffing, compounds or grit Maximum Capacity lbs/hr 10 F Below Saturation (Kg/hr 5 C Below Saturation Differential PSIG (bar) Trap Orifice Inches (0.34) (0.7) (1.4) (2.1) (2.8) (3.4) (4.2) (4.9) (5.6) (6.2) (6.9) CDH 1/4 (249) (374) (549) (678) (794) (896) (987) (1066) (1145) (1202) (1281) For Kg/Hr Multiply by.454 U.S. PATENT NO. 6,220,519
8 8 APPLICATIONS CIP/SIP System Condensate Drainage Sterilization of Process Vessels Culinary Steam Humidifiers WFI System Sterilization Main Drips APPLICABLE CODES ASME BPE Canadian Registration # 0E0591.9C DS100/DS110 THERMOSTATIC STEAM TRAPS Pressures To 150 PSIG (10.3 barg) Temperatures to 366 F (186 C) Stainless Steel Body Body materials of all models are Type 316L Stainless Steel. Self Centering Valve Leak tight shut off. Assembly of actuator and valve to impingement plate allows valve to self-align with center of valve seat orifice. Provides long lasting valve and seat. Temperature Sensitive Actuator 316L Stainless welded actuator for maximum corrosion, thermal and hydraulic shock resistance. One moving part. Thermal and Hydraulic Shock Resistant Impingement plate plus welded construction prevents damage to actuator. Long Life Valve and Seat Stainless steel valve and seat matched together for water tight seal. Maintenance All models are sealed and maintenance free. Directional Discharge Erosion prevented by directing discharge into the center of pipe or tubing. Best Air Handling Capacity Fast start up and operation. Fast Response Quickly adjusts to condensate load or temperature changes. One Size Suits Most Services Universal hygienic clamp fits both 1/2" and 3/4" piping. Two Year Guarantee Trap guaranteed for two years against defects in material or workmanship. MODELS DS100 Hygienic Clamp end 1 7 8" OAL DS100TE Tube end DS110 Hygienic Clamp end 2 5 8" OAL NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required. OPERATION Thermal actuator is filled at its free length with a liquid having a lower boiling point than water. On start-up, valve is normally open to discharge air, non-condensibles and condensate. When steam enters trap, thermal actuator fill vaporizes to a pressure higher than line pressure. This forces valve into seat orifice to prevent any further flow. As condensate collects, it takes heat from thermal actuator, lowering internal pressure. Line pressure will then compress thermal actuator to open valve and discharge condensate. Valve opening automatically adjusts to load conditions from minimum on very light loads to full lift at maximum load.
9 DS100/DS110 THERMOSTATIC STEAM TRAPS SPECIFICATION Steam trap shall be thermostatically actuated and maintenance free. Actuator shall be of single piece, fail open design consisting of 1.2" diameter, welded 316L stainless plates capable of releasing condensate within 5ºC (10ºF) of saturated pressure. Trap shall be constructed entirely of 316L stainless steel components with wetted body surfaces finished to 20 µ inch (0.5 µm) Ra or better. Trap shall be self draining when installed vertically in piping systems. Trap shall have tube or universal hygienic clamps. Ferruled connections shall be Tri-clamp compatible and designed to fit both 1 /2" and 3 /4" service. Trap shall be guaranteed against defects for 2 years. MAXIMUM OPERATING CONDITIONS PMO: Max. Operating Pressure 150 psig (10.3 barg) TMO: Max. Operating Temperature 366 F (170 C) PMA: Max. Allowable Pressure 300 psig* (20.7 barg) TMA: Max. Allowable Temperature 500 F* (260 C) *May be limited by rating of utilized end connection. MATERIALS OF CONSTRUCTION Body Inlet A L Actuator 316L Body Outlet A L Valve 316L 1 3 4" (44.5) DS100 HYGIENIC CLAMP CONNECTION 1/2" & 3/4" Weight.4 lbs (0.18) 4 7 8" (104.8) 1 3 4" (44.5) 1 7 8" (47.6) 9 BODY SURFACE FINISH Internal <20 µ in. (0.5 µm) Ra SFCI.External <32 µ in. (0.75 µm) Ra. Optional mechanical polishing to 10 µ in. (0.25 µm) Ra and/or electropolish SFC4 SERVICE NOTES Trap is designed to be self draining for vertical installation (discharge down). 1 /2" - 3 /4" ferrule service trap should be installed with 3 /4" inlet gasket. SLR ORIFICE OPTION Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. Maximum Capacity lbs/hr 10 F Below Saturation (Kg/hr 5 C Below Saturation) Differential PSIG (bar) Trap Orifice Inches (0.34) (0.7) (1.4) (2.1) (2.8) (3.4) (4.2) (4.9) (5.6) (6.2) (6.9) (8.62) (10.3) DS100 1/ (249) (374) (549) (678) (794) (896) (987) (1066) (1145) (1202) (1281) (1424) (1554) DS100TE TUBE CONNECTION (1/2" & 3/4") Weight.4 lbs (0.18) 2 5 8" (66.7) 1 3 4" (44.5) DS110 HYGIENIC CLAMP CONNECTION (1/2" & 3/4") Weight.4 lbs (0.18) Connections: 1/2" 3/4" Tube 1/2" / 3/4" Hygienic Clamp
10 10 DS200 SERIES THERMOSTATIC STEAM TRAPS Pressures To 100 PSIG (6.9 barg) Temperatures to 338 F (170 C) APPLICATIONS Platen Presses Plating Tanks Sterilizers Tire Presses Cooking Equipment Laundry Equipment Other Process Equipment OPTION -B Bellows for low subcool Stainless Steel Body Body materials are Type 316L Stainless Steel. Self Centering Valve Leak tight shut off. Assembly of actuator and valve to impingement plate allows valve to self-align with center of valve seat orifice. Provides long lasting valve and seat. Temperature Sensitive Actuator One moving part. Inconel welded actuator for maximum corrosion, thermal and hydraulic shock resistance. Thermal and Hydraulic Shock Resistant Impingement plate plus welded construction prevents damage to actuator. Valve and Seat Long life, stainless steel valve and seat lapped and matched together for water tight seal. Maintenance All models are sealed and maintenance free. Three Year Guarantee Trap guaranteed for three years against defects in material or workmanship. Additional Features Best air handling capability for fast start up and operation. Fastest response to condensate load or temperature changes. Broad application range. Selection of orifice and pipe sizes meet majority of condensate removal demands in deionized steam systems. Unique SLR Orifice Option Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. MODELS DS202 Low capacity DS203 Medium capacity DS204 High capacity Canadian Registration # OE0591.9C OPERATION Thermal actuator is filled at it s free length with a liquid having a lower boiling point than water. As assembled, valve is normally open. On startup, air passes through vent.as air is eliminated, hot steam reaches vent and the thermal actuator fill vaporizes to a pressure higher than line pressure. This forces valve into seat orifice to prevent any further flow. Should more air collect, it takes heat from the actuator, lowering internal pressure. Line pressure will then compress thermal actuator to open valve and discharge air. Valve lift automatically adjusts to variations.
11 DS200 SERIES THERMOSTATIC STEAM TRAPS A 11 Steam trap shall be of balanced pressure design with 316L welded bellows capable of releasing condensate within 5ºC (10 F) of saturated pressure. Where drainage at saturated temperatures is required, trap shall have SLR orifice. All other components shall be of 316 or 316L stainless steel. Trap shall be self draining and normally open. MAXIMUM OPERATING CONDITIONS PMO: Max. Operating Pressure 100 psig (6.9 barg) TMO: Max. Operating Temperature 338 F (170 C) PMA: Max. Allowable Pressure 150 psig (10.3 barg) TMA: Max. Allowable Temperature 366 F (186 C) MATERIALS OF CONSTRUCTION SPECIFICATION Body ASTM A351 Grade CF3M (316L) Welded Actuator 316L Fittings & Plates Valve & Seat 316L Stainless Steel B Connections: 3/8" 3/4" NPT or socketweld NPT or Socket Weld 3 8 and /8" - 3/4" BODY DIMENSIONS inches (mm) and WEIGHTS pounds (kg) A B Weight (95) (44) (0.5) (100) (44) (0.54) SLR ORIFICE OPTION Specify when immediate elimination of condensate and improved sensitivity is desired. An orifice on the valve allows for continuous discharge of condensate. Trap will nominally pass 50 lb/hr (22.7 kg/hr) of condensate at 50 psi (3.4 barg) within 0.5ºC (1 F) of saturated temperature. -B BELLOWS 1ºC (2-3ºF) subcool for sensitive applications under 40 psi (2.7 barg) Maximum Capacity lbs/hr 10 F Below Saturation (Kg/hr 5 C Below Saturation) Orifice Differential PSIG (bar) Trap Inch (mm) (0.34) (0.7) (1.4) (3.5) (6.9) (8.6) (10.3) (13.8) (17.2) (20.7) (24.1) (27.6) (31.0) (34.5) DS202 1/ (3) (98) (120) (170) (269) (354) (381) (405) (445) (480) (510) (536) (561) (584) (601) DS203 DS204 1/ (6) (249) (374) (549) (896) (1281) (1424) (1554) (1656) (1796) (1860) (1919) (2005) (2086) (2161) 5/ (8) (390) (554) (783) (1237) (1623) (1748) (1857) (2045) (2202) (2340) (2463) (2576) (2679) (2774)
12 12 APPLICATIONS Steam Tracing Drip Leg Heating Sanitary Applications SANITIZER NTD 230L SERIES SANITARY THERMODYNAMIC STEAM TRAPS Pressures To 150 PSIG (10.3 barg) Temperatures to 850 F (454 C) Sanitary 316L stainless steel bar stock body, disc and cap, with surface finishes better than 32m in. Ra, prevent contamination and rouging. Compact Design Stainless steel disc is the only moving part. Inexpensive Low initial cost is less expensive than repairable technologies. Simplifies Installation Works in any position. Rugged Handles water hammer and superheat. Reliable, Efficient Operation Blast discharge quickly draws condensate and helps maintain system temperature. Freeze resistant Self draining design with vertical install drain prevents freezing. All 316L Stainless Steel Construction Resists both internal and external corrosion. Easy to Monitor Audible discharge cycle makes checking operation simple. MODELS NTD 230L Sanitizer Thermodynamic Steam Trap NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required. OPERATION Incoming air and condensate flow through the trap body and into the control chamber. Line pressure raises the disc off the seat, allowing complete discharge. When flashing condensate enters the cartridge, flow velocity increases, creating low pressure underneath the disc. Flashing condensate at high velocity strikes the inside wall of the disc chamber and is deflected to the top of the disc, causing a pressure buildup. The disc is forced down onto the seat by this pressure imbalance. The trap remains closed as flashed vapor in the control chamber keeps the disc seated. Pressure inside the cap is not lowered until the trapped flash vapor condenses due to body radiation. Condensing steam lowers the pressure above the disc. Disc is then lifted and the cycle repeated.
13 SANITIZER NTD 230L SERIES SANITARY THERMODYNAMIC STEAM TRAPS SPECIFICATION Steam Trap shall be of the thermodynamic design. Body shall be of 316L stainless steel construction. Surface finishes shall exceed 32 µ in. (0.75 µm) grade. Trap body shall contain an integral seat. Cover shall seal to body without gaskets or seals. Trap shall be suitable for pressures through 150 PSI (10.3 barg). Trap end connections shall be hygienic clamp and accommodate mating connection sizes of 1/2 and 3/4 inch. Trap shall function installed in any pipe configuration. C B A 13 MAXIMUM OPERATING CONDITIONS PMO: Max. Operating Pressure TMO: Max. Operating Temperature PMA: Max. Allowable Pressure TMA: Max. Allowable Temperature 150 psig (10.3 barg) 850 F (454 C) 230 psig (15.9 barg) 850 F (454 C) MATERIALS OF CONSTRUCTION Body 316L Stainless Steel Bar Stock Disc 316L Stainless Steel Bar Stock Cover 316L Stainless Steel Bar Stock Maximum Capacity lbs/hr (10 F Below Saturation) Differential PSIG (barg) Orifice (0.34) (0.7) (1.4) (3.4) (6.9) (8.6) (10.3) For Kg/Hr Multiply by.454 Connections: 1 2" / 3 4" Hygienic Clamp DIMENSIONS inches (mm) and WEIGHTS pounds (kg) A B C Weight (66) (38) (51) (0.59)
14 14 STEAM SCRUBBER STAINLESS STEEL FILTER SIZES 1 /2" to 3" PRESSURES to 145 PSIG at 353 F 1 and 5 Micron Filters meet or exceed FDA guidelines and comply with 3A 304 Stainless Steel Housing Electropolished and Passivated Double O-ring EPDM Housing Gasket Inline NPT Connections Single Clamp Closure Sintered 316 Stainless Steel Filter Media Porosity Level greater than 50% Filter Media in 1, 5 or 25 Micron Absolute Ratings STEAM SCRUBBER FILTER APPLICATION DATA Culinary Grade Steam Sterilizers Autoclaves Pharmaceutical & Biotechnology Process Equipment Clean Room Humidification Chemical Industry Electronic Industry Plastic Industry OPTIONS 316L Housing Silicone, Viton or Buna N Gaskets Flange or Welded Ends 4" to 8" with ANSI Flanged End Filter Element Endcaps 304 Stainless Steel Renewable Filter Media Single Open End Filter Media MODELS SS2L 2" low capacity SS3L 3" low capacity SS12 1/2" standard capacity SS34 3/4" standard capacity SS1 1" standard capacity SS114 11/4" standard capacity SS112 11/2" standard capacity SS2 2" standard capacity SS212 21/2" standard capacity SS3 3" standard capacity NOTE: Please specify if Material Test Reports (MTR) or Certificates of Conformance (COC) are required. Canadian Registration #OE8186.8O REQUIRES DRIP TRAP. COMBINE WITH DS200 TRAP FOR MOST CLEAN STEAM APPLICATIONS DS200 TRAP ON PAGE 10
15 STEAM SCRUBBER STAINLESS STEEL FILTER C G 15 SPECIFICATION Furnish and install as shown on the plans, high efficiency, inline horizontal, filter for air, steam or gas constructed with 304 or 316L stainless steel housing and single, open ended element. Filter shall have an absolute rating of 1, 5 or 25 microns and utilize double o-ring gaskets to reduce potential downstream leakage of unfiltered medium. External surface finish of filter housing shall be no less than 180 grit (25-35 Ra microinch) and joined utilizing a single clamp. Filter media shall be of sintered 316L stainless steel and be regenerable. 1 and 5 micron media shall conform to 3A sanitary standards for production of culinary steam and be USDA accepted. Connections shall be NPT, flanged ANSI 150 or welded. 1/4" NPT B MAXIMUM OPERATING CONDITIONS* PMO: Max. Operating Pressure 145 psig (10 barg) Limit for Saturated Steam 125 psig (8.6 barg) TMO: Max. Operating Temperature 353 F (178 C) PMA: Max. Allowable Pressure 232 psig / F (16 barg / C) TMA: Max. Allowable Temperature 400 F / psig (204 C / 0-16 barg) *For differential pressures greater than 75 psig, consult factory. MATERIALS OF CONSTRUCTION Body, Standard 304 Stainless Steel Body, Optional 316L Stainless Steel Clamp 304 Stainless Steel Plug 304 Stainless Steel Gasket, Standard EPDM Gasket, Optional Silicone Gasket, Optional Viton Gasket, Optional Buna N Filter Media Sintered 316L Stainless Steel Filter End Caps 304 Stainless Steel (kg/hr) (lb/hr) Saturated Steam Capacity 2"L, 250 F, 15 PSI (Cm)* 1/4" NPT D Connections: 1/2" 3" NPT, Flanged or Welded DIMENSIONS inches (mm) and WEIGHTS pounds (kg) Size A B C D G Weight Conversion Factors (Cs) 1 /2 2 1 /8 7 3 /8 2 3 /4 4 1 /8 3 3 /4 4.2 (15) (55) (188) (70) (108) (95) (1.9) /4 2 1 /8 8 3 /8 2 3 /4 4 7 / (20) (55) (211) (70) (125) (152) (2.0) /8 8 5 /8 3 3 /8 4 7 / (25) (74) (219) (85) (125) (152) (2.6) /4 2 7 / /8 3 3 /8 5 1 / (32) (74) (270) (85) (140) (203) (3) /2 3 3 / /2 4 1 /8 6 5 / (40) (94) (292) (104) (170) (203) (4.6) L* 3 3 / /8 4 1 /8 6 5 / (50) (94) (366) (104) (170) (279) (4.8) / /8 4 1 /8 6 5 / / (50) (94) (493) (104) (170) (451) (5.3) /2 4 1 / /8 5 1 /8 8 1 / (65) (106) (626) (129) (216) (584) (9) L* 4 1 / /8 5 1 /8 8 1 / / (80) (106) (881) (129) (216) (851) (10.8) / / / / (80) (119) (907) (152) (240) (851) (16.2) 4.00 A Volumetric flow micron 5 micron 1 micron SELECTION EXAMPLE For optimum service life, the filter should have a 1 psi maximum pressure drop. Select a 5 micron filter for a flow rate of 110 lbs/hr (w) of saturated steam at 45 psi. Where: Cs = w CmCp Designing for.75 PSI differential pressure, Cm is 225 from the capacity chart and Cp is 2.0. Therefore: Cs = 110 =.24 so 3/4" should be used. (225)(2.0) Differential pressure *For other pressures and sizes, see conversion factors PSI bar Steam Pressure Conversion Factors (Cp) PSI Steam Pressure bar Conversion factor
16 16 SANITARY STEAM TRAP SUMMARY SUMMARY CoMBo CDS CDH DS100/DS110 NTD230L DS200 SIZES (Inches) 1/2, 3/4 1/2, 3/4, 1, /2, 3/4 1/2, 3/4 1/2, 3/4 3/8, 1/2, 3/4 MAXIMUM PRESSURE (PSI) CLEANABLE YES YES YES NO YES NO INTERNAL FINISH < 20 µ In. < 20 µ In. < 20 µ In. < 20 µ In. < 32 µ In. 125 CONNECTIONS FLOW HYGIENIC HYGIENIC HYGIENIC HYGIENIC HYGIENIC CLAMP CLAMP CLAMP CLAMP CLAMP & TUBE VERTICAL & HORIZONTAL NPT VERTICAL HORIZONTAL VERTICAL HORIZONTAL VERTICAL FREE DRAINING YES YES YES YES NO NO ASME BPE COMPLIANT YES YES YES YES NO NO SLR SLR SLR MECHANICAL MECHANICAL MECHANICAL OPTIONS POLISH POLISH POLISH SLR SLR ELECTRO- ELECTRO- ELECTRO- POLISH POLISH POLISH -B BELLOWS -B BELLOWS All traps are exclusively 316L
DESIGNER S GUIDE STEAM TRAPS & SPECIALTIES
Mechanical Steam Traps Thermostatic Steam Traps Thermodynamic Steam Traps Condensate Pumps Compressed Air Products Gasketed Unions Sanitary Steam Products Drain Orifice Steam Traps STEAM TRAPS & SPECIALTIES
WD600 STEAM TRAPS. Thermodynamic Steam Trap
WD600 Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company WD600, WD600L Sizes 3/8, 1/2, 3/4, 1 NPT Material Stainless
Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves
Baumann TM Sanitary and Aseptic Process Valves The Company Fisher Controls International LLC, Baumann Control Valves, is an ISO 9001 certified, PED compliant manufacturer of general utility, precision
VAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
Baumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
NICHOLSON STEAM TRAP. 845.778.5566 Fax: 845.778.7123 www.nicholsonsteamtrap.com STEAM TRAP
1 NICHOLSON STEAM TRAP Nicholson Steam Trap was founded in 1883 by W. H. Nicholson, Sr. He, along with his sons William, George and Samuel produced a variety of steam specialty products at their facility
SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration
SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration FBSPAKMSWAEN Technical Information SUPRApak Multi-Stack Series-WA housings are designed for use with SUPRApak
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration
SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration FBSPAKMSAENf Technical Information SUPRApak M Series-SA filtration units are turn-key systems designed for use with
STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE
Page 1 of 9 PURPOSE Steam is the most commonly used heating medium for maintaining process temperatures. Compared to other heating media, steam contains a significant amount of heat energy, and this heat
MFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
Stainless Steel Valves For the Sanitary Industries
www.swagelok.com Stainless Steel Valves For the Sanitary Industries Sanitary ball valves Manual and pneumatically actuated butterfly valves Disk and ball check valves ir blow check valves ir relief valves
BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap
1263050/6 IM-P126-07 ST Issue 6 BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation
Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing 408-409
Engineering Data Table of Contents Page No. I II Formulas, Conversions & Guidelines Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Sizing 408-409 Steam
SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration
SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration FBSPAKSWASAENc SUPRApak Series SUPRApak S Series Filter Housings Technical Information SUPRApak S series filter housings
DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for
CSF16 and CSF16T Stainless Steel Steam Filters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
PBM has solutions for your valve application.
valve solutions i n d u s t r i a l v a l v e s Whether the application is in a chemical plant, paper mill, food plant, manufacturing environment, or other industrial setting, PBM S line of Industrial
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
Blowdown vessels Meeting the requirements of HSE PM60
Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
REGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING
By Philip Sutter Pick Heaters, Inc. DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING INTRODUCTION Many process plants currently use steam or hot water to heat jacketed devices such as tanks,
Steam Jet Vacuum Pumps
By: S.G. Ketterer and C.G. Blatchley The use of steam jet ejectors for entraining air or gases at subatmospheric pressures is increasing rapidly, particularly in the range of pressures below mm absolute.
Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation
Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment Larry Zanko Project Manager STERIS Corporation Agenda Brief overview of multiple-effect water stills (MWS) Lean advancements
3M Housings DS Series
Lenntech [email protected] Tel. +1-15-610-900 www.lenntech.com Fax. +1-15-616-89 M Housings For Filters Filter Housings, constructed of durable stainless steel, meet general-purpose industrial, chemical,
1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to 9.0 3. Nonvolatile TOC content < 1.0 ppm
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Free Floating Lever Drain Traps For Loads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar)
Free Floating ever rain Traps For oads to 50,000 lb/hr (22,679 kg/hr)...pressures to 1,000 psig (69 bar) iquid rainers Table -14. Maximum Operating Pressures for Handling ifferent Specific Gravity iquids
valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper www.quilinox.
valve solutions www.quilinox.com Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper valvulas esfera PBM.pdf (1753) 2015/01 1/10 D E SIGN F E A
Desuperheater Online Program Sizing Guidance
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Steam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:
LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have
MUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
Air Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
How To Make A Jorlon Diaphragm
Steriflow is the single source for high performance, high quality, sanitary valves. Steriflow has earned its reputation for quality through nearly two decades of success in bio-pharmaceutical, pharmaceutical,
FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS
FILTRATION SOLUTIONS Pharmaceutical Manufacturing filtration specialists Delivering quality filtration products As one of Europe s leading manufacturers of process filters, Amazon Filters is able to offer
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.
Steam Tables What They Are How to Use Them The heat quantities and temperature/ pressure relationships referred to in this Handbook are taken from the Properties of Saturated Steam table. Definitions of
Submersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve
61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve Features Rounded polished disc edge gives full concentric sealing, lower torques, longer seat life
Questionnaire Pure Media Systems
1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve
Order Code for VESTA Sterile Valves Type H_A 2/2 Way Seat Valve engineering for a better world GEA Mechanical Equipment VESTA Sterile Valves are designed for universal use in sterile process technology.
FT43, FT44, FT46 and FT47 Ball Float Steam Traps
0667050/9 IM-S02-30 ST Issue 9 FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
HS-901(A) BASIC STEAM HEATING SYSTEMS
HS-901(A) BASIC HEATING SYSTEMS One-Pipe Two-Pipe Basic Steam Heating Systems One-pipe steam heating system EQUALIZER SAFETY FACTOR STATIC HEAD PRESSURE DROP 2" HEATING UNIT 15" DRIP CONNECTION In a one-pipe,
Fig B36 Stainless Steel 'T' Type or Basket Type Strainers
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
CHEXTER TM FITS YOUR APPLICATION, PROFITABLY
CHEXTER TM FITS YOUR APPLICATION, PROFITABLY Commercial Construction CHEXTER TM Check Valves are economically used in chilled and hot water air conditioning systems, refrigeration and other piping and
Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves
Non-Code Liquid Relief, ASME Section VIII, Air/Gas and Steam, National Board Certified, Safety and Relief Valves Features Top guided design offers high capacity with 0.110 in 2 [0.710 cm 2 ] orifice area.
The BPE 2012 Edition & Project 2012 Requirements & Resources for Bioprocess Systems Design
The BPE 2012 Edition & Project 2012 Requirements & Resources for Bioprocess Systems Design Reinhard Hanselka, PhD Director of Code Compliance & Environmental Engineering, M+W Group, Alameda, CA Ray Foley
BSL3 and BSL4 Autoclaves. Laboratory Line
BSL3 and BSL4 Autoclaves Laboratory Line BSL3 and BSL4 Autoclaves In today s society the need for safe bio-containment systems is increasingly important. This is especially true in the sterilization process
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
In-Line Air Separators
Air Elimination & Control In-Line Air Separators The AC models of air separators deliver all the quality and performance you expect from Taco products. They are built to last with shell, heads and ANSI
NORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
Steam Coil Installation, Operation and Maintenance
Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils manufactured by Luvata in Grenada, MS have been
167D Series Switching Valves
June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are
Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description
Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard
TECHNICAL DATA. Dry 122a. November 12, 2013
Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
Morrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
AUTOMATIC CHANGEOVER MANIFOLD Series 915
AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Ultipleat High Flow Filter System
Data Sheet PIUFFSENa Ultipleat igh Flow Filter System Description The Ultipleat igh Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside-to-outside flow pattern.
Direct steam injection humidifiers
Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature
Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
Copper Meter Resetters
Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710
Steam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
Mechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
Pipe Valves, Fittings and Nipples Pressures to 15,200 psi
Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by
REGULATING VALVE APPLICATIONS
REGULATING APPLICATIONS GENERAL REGULAR APPLICATION & INSTALLATION NOTES Regulator Application & Installation Notes The following are considerations for all steam regulator installations, as system operation
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Type 92S Pilot-Operated Steam Regulator
Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots
Thermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
Baumann 81000 Mikroseal Control Valve
Product Bulletin D103340X012 Baumann 81000 Mikroseal Control Valve The Baumann 81000 Mikroseal control valve (figures 1 and 2) is excellent for throttling of liquid or gaseous media, particularly where
Element D Services Plumbing
PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
RMF Engineering 23 05 23
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
CUNO High Flow Filtration Systems
Lenntech Tel. +31-152-610-900 Fax. +31-152-616-289 CUNO High Flow Filtration s High Flow Performance Compact Design Innovative technology to achieve flow rates up to 500 gpm per element Absolute-rated
Laboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
Laboratory & Scientific Line. Horizontal Steam Sterilizers
Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
Self-contained valve functions as integral check valve, flow sensing element and bypass control valve.
Self-contained valve functions as integral check valve, flow sensing element and bypass control valve. Features Eliminates high cost of installation and maintenance of complex conventional flow control
Mechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Pressure reducing valves. for steam and industrial fluids
Pressure reducing valves for steam and industrial fluids Pressure reducing valves For steam and industrial fluids A well designed steam system will produce clean dry steam in the boiler house ready for
Select the Right Relief Valve - Part 1 Saeid Rahimi
Select the Right Relief Valve - Part 1 Saeid Rahimi 8-Apr-01 Introduction Selecting a proper type of relief valve is an essential part of an overpressure protection system design. The selection process
