VSI-1104-A SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE. Vertu SERIES
|
|
|
- Marylou Riley
- 9 years ago
- Views:
Transcription
1 VSI-1104-A SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE Vertu SERIES
2 CONTENTS 1. Precaution Safety Precaution Warning Function Dimension Indoor Unit Outdoor Unit Refrigerant Cycle Diagram Wiring Diagram Indoor Unit Outdoor Unit Installation details Wrench torque sheet for installation Connecting the cables Pipe length and the elevation Air purging with vacuum pump Pumping down (Re-installation) Re-air purging (Re-installation) Balance refrigerant of the 2-way, 3-way valves Evacuation Gas charging Operation characteristics Electronic function Abbreviation Display function Main Protection Operation Modes and Functions Troubleshooting Indoor Unit Error Display Diagnosis and Solution... 48
3 1. Precaution 1.1 Safety Precaution To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. Before service unit, be sure to read this service manual at first. 1.2 Warning Installation Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit. There is risk of fire or electric shock. For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service center. Do not disassemble or repair the product, there is risk of fire or electric shock. Always ground the product. There is risk of fire or electric shock. Install the panel and the cover of control box securely. There is risk of fire of electric shock. Always install a dedicated circuit and breaker. Improper wiring or installation may cause fore or electric shock. Use the correctly rated breaker of fuse. There is risk of fire or electric shock. Do not modify or extend the power cable. There is risk of fire or electric shock. Do not install, remove, or reinstall the unit by yourself(customer). There is risk of fire, electric shock, explosion, or injury. Be caution when unpacking and installing the product. 1
4 Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and evaporator. For installation, always contact the dealer or an Authorized service center. There is risk of fire, electric shock, explosion, or injury. Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product. Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open. Moisture may condense and wet or damage furniture. Take care to ensure that power cable could not be pulled out or damaged during operation. There is risk of fire or electric shock. Do not place anything on the power cable. There is risk of fire or electric shock. Do not plug or unplug the power supply plug during operation. There is risk of fire or electric shock. Do not touch (operation) the product with wet hands. There is risk of fire or electric shock. Do not place a heater or other appliance near the power cable. There is risk of fire and electric shock. Do not allow water to run into electric parts. It may cause fire, failure of the product, or electric shock. Do not store or use flammable gas or combustible near the product. There is risk of fire or failure of product. Do not use the product in a tightly closed space for a long time. Oxygen deficiency could occur. When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. 2
5 Do not use the telephone or turn switches on or off. There is risk of explosion or fire. If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire. Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives. There is risk of property damage, failure of product, or electric shock. Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure. When the product is soaked (flooded or submerged), contact an Authorized service center. There is risk of fire or electric shock. Be caution that water could not enter the product. There is risk of fire, electric shock, or product damage. Ventilate the product from time to time when operating it together with a stove, etc. There is risk of fire or electric shock. Turn the main power off when cleaning or maintaining the product. There is risk of electric shock. When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. There is risk of product damage or failure, or unintended operation. Take care to ensure that nobody could step on or fall onto the outdoor unit. This could result in personal injury and product damage. CAUTION Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product. Install the drain hose to ensure that water is drained away properly. 3
6 A bad connection may cause water leakage. Keep level even when installing the product. To avoid vibration of water leakage. Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. It may cause a problem for your neighbors. Use two or more people to lift and transport the product. Avoid personal injury. Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation. Operational Do not expose the skin directly to cool air for long periods of time. (Do not sit in the draft). This could harm to your health. Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigerant system. There is risk of damage or loss of property. Do not block the inlet or outlet of air flow. It may cause product failure. Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. There is risk of fire, electric shock, or damage to the plastic parts of the product. Do not touch the metal parts of the product when removing the air filter. They are very sharp. There is risk of personal injury. Do not step on or put anything on the product. (outdoor units) There is risk of personal injury and failure of product. Always insert the filter securely. Clean the filter every two weeks or more often if necessary. 4
7 A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. Do not insert hands or other object through air inlet or outlet while the product is operated. There are sharp and moving parts that could cause personal injury. Do not drink the water drained from the product. It is not sanitary could cause serious health issues. Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal injury. Replace the all batteries in the remote control with new ones of the same type. Do not mix old and mew batteries or different types of batteries. There is risk of fire or explosion. Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. They may burn of explode. If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote of the batteries have leaked. The chemical in batteries could cause burns or other health hazards 5
8 2. Function Model List Indoor units MSV1-18HRDN1-QC2F(D) MSV1-24HRDN1-QC2W MSV1-18HRDN1-QC2F(E) MSV1-09HRDN1-QC2 MSV1-12HRDN1-QC2 MSV1-09HRFN1-ND2E MSV1-12HRFN1-ND0E MSV1-09HRDN1-QC8 MSV1-12HRDN1-QC4 MSV1-09HRDN1-QC2(D) MSV1-12HRDN1-QC2(D) Outdoor units MOC2-18HDN1-QC2 MOF-24HDN1-QC2W MOC2-18HDN1-QC2 MOR-09HDN1-QC2 MOR-12HDN1-QC2 MOC-09HDN1-ND2E MOC1-12HFN1-ND0E MOC-09HDN1-QC8 MOC-12HDN1-QC4 MOA-09HDN1-QC2 MOB4-12HDN1-QC2 6
9 Indoor unit Operation by remote controller Sensing by room temperature Room temperature sensor. Pipe temperature sensor. Room temperature control Maintain the room temperature in accordance with the setting temperature. Anti-freezing control in cooling Prevent the water being frozen on evaporator by sensing the evaporator pipe temperature in cooling mode Time Delay Safety control Restarting is for approx. 3 i t Indoor fan speed control Turbo, high, med, low, breeze. Indoor golden fin Ionizer Self clean Follow me Two-direction air vane The unit will decide the louver direction according to operation mode. Timer function Sleep mode auto control The fan is turn to low speed (cooling/heating). Independent dehumidification The function is usually used in rainy days in springtime or damp areas. Air flow Direction control The louver can be set at the desired position or swing up and down automatically Auto mode The mode can be change by the room temperature. Temp. Compensation Self-diag. function Anti-cold function Prevent the cold wind at the beginning of unit start. Auto defrost Auto-restart function When the power supply is interrupted and then restore, the air conditioners automatically restore the previous function setting. Flexible wiring connection 7
10 Outdoor unit Power relay control The unit has 3 minutes delay between continuously ON/OFF operations. Low noise air flow system Bird tail propeller fan makes the outdoor unit run more quietly. Hydrophilic aluminum fin The hydrophilic fin can improve the heating efficiency at operation mode. 4 way valve control It is only operated in the heating operation mode except defrosting operation. Anti-rust cabinet Made from electrolytic zinc steel sheet and anti-rust coated components. Valve protection cover It protects the valves and prevents water from dripping. Discharge pipe temperature protect Crankcase heating cable Driving heating at -15 8
11 3. Dimension 3.1 Indoor Unit Model Dimension (mm) W H D MSV1-09HRDN1-QC2 MSV1-09HRDN1-QC2(D) MSV1-12HRDN1-QC2 MSV1-09HRFN1-ND2E MSV1-12HRFN1-ND0E MSV1-09HRDN1-QC MSV1-12HRDN1-QC4 MSV1-12HRDN1-QC2(D) MSV1-18HRDN1-QC2F(D) MSV1-18HRDN1-QC2F(E) MSV1-24HRDN1-QC2W
12 3.2 Outdoor Unit Model Dimension (mm) W D H W1 A B MOR-09HDN1-QC2 MOR-12HDN1-QC MOC2-18HDN1-QC2 MOC-09HDN1-ND2E MOC1-12HFN1-ND0E MOC-12HDN1-QC4 MOC-09HDN1-QC MOF-24HDN1-QC2W MOA-09HDN1-QC MOB4-12HDN1-QC
13 4. Refrigerant Cycle Diagram 11
14 5. Wiring Diagram 5.1 Indoor Unit MSV1-09HRDN1-QC2 MSV1-12HRDN1-QC2 MSV1-18HRDN1-QC2F(D) MSV1-09HRDN1-QC8 MSV1-12HRDN1-QC4 MSV1-09HRDN1-QC2(D) MSV1-12HRDN1-QC2(D) 12
15 MSV1-24HRDN1-QC2W MSV1-18HRDN1-QC2F(E) 13
16 MSV1-09HRFN1-ND2E MSV1-12HRFN1-ND0E 14
17 5.2 Outdoor Unit MOR-09HDN1-QC2 MOR-12HDN1-QC2 15
18 MOC2-18HDN1-QC2 MOF-24HDN1-QC2W 16
19 MOC2-18HDN1-QC2 17
20 MOC-09HDN1-ND2E MOC1-12HFN1-ND0E 18
21 MOC-09HDN1-QC8 MOC-12HDN1-QC4 19
22 MOA-09HDN1-QC2 MOB4-12HDN1-QC2 20
23 6. Installation details 6.1 Wrench torque sheet for installation Outside diameter mm inch Ф6.35 1/4 Ф9.53 3/8 Ф12.7 1/2 Ф16 5/8 6.2 Connecting the cables Torque N.cm 1570 (160kgf.cm) 2940 (300kgf.cm) 4900 (500kgf.cm) 7360 (750kgf.cm) Additional tightening torque N.cm 1960 (200kgf.cm) 3430 (350kgf.cm) 5390 (550kgf.cm) 7850 (750kgf.cm) he power cord of connect should be selected according to the following specifications sheet. Rated current of appliance Nominal cross-sectional area (mm²) >3 and >6 and >10 and >16 and The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit. Please refer to the nameplate before selecting the cable, fuse and switch. 21
24 6.3 Pipe length and the elevation Capacity Btu/h Gas Pipe size Liquid Standard length (m) Max. Elevation B (m) Max. Length A (m) Additional refrigerant (g/m) MSV1-09HRDN1-QC2 MSV1-12HRDN1-QC2 MSV1-09HRFN1-ND2E MSV1-09HRDN1-QC8 4/8 (Ф6.35) 3/8 (Ф9.53) MSV1-09HRDN1-QC2(D) MSV1-18HRDN1-QC2F(E) MSV1-18HRDN1-QC2FD 1/2 (Ф12.7) 4/8 (Ф6.35) MSV1-12HRFN1-ND0E MSV1-12HRDN1-QC4 MSV1-12HRDN1-QC2(D) 1/2 (Ф12.7) 4/8 (Ф6.35) MSV1-24HRDN1-QC2W 5/8 (Ф16) 3/8 (Ф9.53) Caution: Capacity test is based on standard length and maximum allowance length is based on reliability. Oil trap should be installed per 5-7 meters. 22
25 6.4 Air purging with vacuum pump Air and moisture in the refrigerant system have undesirable effects as below: Pressure in the system rises. Operating current rises. Cooling or heating efficiency drops. Moisture in the refrigerant circuit may freeze and block capillary tubing. Water may lead to corrosion of parts in the refrigerant system. Therefore, the indoor units and the pipes between indoor and outdoor units must be leak tested and evacuated to remove gas and moisture from the system. Air purging with vacuum pump (Indoor unit) (Liquid side) (Outdoor unit) Two-way valve Close (Gas side) Manifold valve Compound meter Pressure gauge -76cmHg Lo Hi Three-way valve Close Handle Lo Charge hose Handle Hi Charge hose Vacuum pump adaptor Vacuum pump Procedure 1. Completely tighten the flare nuts of the indoor and outdoor units, connect the manifold valve charge. 2. Connect the charge hose connection to the vacuum pump. 3. Fully open the handle Lo of the manifold valve. 4. Operate the vacuum pump to evacuate. After starting evacuation, slightly loose the flare nut of the Lo valve on the gas pipe side and check the air is entering. (Operation noise of the vacuum pump changes and a compound meter indicates 0 stead of minutes) 5. After the evacuation is complete, fully close the handle Lo valve of the manifold valve and stop the 23
26 operation of the vacuum pump. Make evacuation for 15 minutes or more and check the compound meter indicates -76cmHg. 6. Turn the stem of the Hi valve about 45 counterclockwise for 6 or 7seconds after the gas coming out, then tighten the flare nut again. Make sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure. 7. Remove the charge hose from the Lo pressure charge hose. 8. Fully open the Hi and Lo packed valve. 9. Securely tighten the cap of the packed valve. Gas leak check Soap water method Apply soap water or a liquid neutral detergent on the indoor unit connections or outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping. If bubbles come out, the pipes have leakage. 6.5 Pumping down (Re-installation) Procedure 1. Confirm that both the 2-way and 3-way valves are set to the opened position. Remove the valve stem caps and confirm that the valve stems are in the opened position. Be sure to use a hexagonal wrench to operate the valve stems. 2. Operate the unit for 10 to 15 minutes. 3. Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way 24
27 valve. Connect the charge hose with the push pin to the gas service port. 5. Air purging of the charge hose. Open the low-pressure valve on the charge set slightly to purge air from the charge hose. 6. Set the 2-way valve to the close position. 7. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0.1MPa. 8. Immediately set the 3-way valve to the closed position. Do this quickly so that the gauge ends up indicating 0.3 to 0.5Mpa. Disconnect the charge set, and amount the 2-way and 3-way valve s stem nuts and service port caps. Use a torque wrench to tighten the service port cap. Be sure to check for gas leakage. 6.6 Re-air purging (Re-installation) Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the closed position. 2. Connect the charge set and a charging cylinder to the service port of the 3-way valve. Leave the valve on the charging cylinder closed. 25
28 3. Air purging. Open the valves on the charging cylinder and the charge set. Purge the air by loosening the flare nut on the 2-way valve approximately 45 for 3 seconds then closing it for 1 minute; repeat 3 times. After purging the air, use a torque wrench to tighten the flare nut to on the 2-way valve. 4. Check the gas leakage. Check the flare connections for gas leakage. 5. Discharge the refrigerant. Close the valve on the charging cylinder and discharge the refrigerant until the gauge indicates 0.3 to 0.5 Mpa. 6. Disconnect the charge set and the charging cylinder, and set the 2-way and 3-way valves to the open position. Be sure to use a hexagonal wrench to operate the valve stems. 7. Mount the valve stems nuts and the service port cap. Be sure to use a torque wrench to tighten the service port cap. Be sure to check the gas leakage. 6.7 Balance refrigerant of the 2-way, 3-way valves 26
29 Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve s service port. Leave the valve on the charge set closed. Connect the charge hose with the push pin to the service port. 3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates 0.05 to 0.1Mpa. If there is no air in the refrigeration cycle, it will not be necessary to apply an evacuation. Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil will be discharged. 6.8 Evacuation Procedure: 1. Connect the vacuum pump to the charge set s centre hose. 2. Evacuation for approximately one hour. Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmhg) [vacuum of 4 mmhg or less]. 3. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the gauge needle does not move (approximately 5 minutes after turning off the vacuum pump). 27
30 4. Disconnect the charge hose from the vacuum pump. 6.9 Gas charging Procedure: 1. Connect the charge hose to the charging cylinder. Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. If the refrigerant is R410A, make the cylinder bottom up to ensure liquid charge. 2. Purge the air from the charge hose. Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air (be careful of the liquid refrigerant). 3. Open the valves (Low side) on the charge set and charge the system with liquid refrigerant. 4. Immediately disconnect the charge hose from the 3-way valve s service port. Stopping partway will allow the refrigerant to be discharged. If the system has been charged with liquid refrigerant while operating the air conditioner, turn off the air conditioner before disconnecting the hose. 5. Mounted the valve stem caps and the service port Use torque wrench to tighten the service port cap. Be sure to check for gas leakage. 28
31 7. Operation characteristics Temperature Mode Cooling operation Heating operation Dehumidify operation Room temperature >10 Outdoor temperature 0 ~50-15 ~34 0 ~ 50 CAUTION: 1. If air conditioner is used beyond the above conditions, the certain protections may action. 2. Room relative humidity should be less than 80%. If the air conditioner operates in excess of this value, the surface of the air conditioner may attract condensation. In this case, please set the vertical air louver to its maximum angle (vertically to the floor), and set the fan to high speed. 29
32 8. Electronic function 8.1 Abbreviation T1: Indoor ambient temperature T2: Pipe temperature of indoor heat exchanger T3: Pipe temperature of outdoor heat exchanger T4: Outdoor ambient temperature T5: Discharge temperature 8.2 Display function Icon explanation on indoor display board. TIMER display Illuminated during Timer operation. CLEAN AIR display(optional) Illuminated when Ionizer is activated. TURBO operation display Illuminated when select TURBO function in cooling operation or in heating operation. DIGITAL DISPLAY Displayed the current setting temperature or malfunction code when the air conditioner is in operation. When SELF CLEAN feature is activated, it displays. SC FAN SPEED display Displayed the selected fan speed: LOW( ), MED( ) and HIGH( ). Operation Frequency display This display is separated into five zones. The zones illuminate based on the compressor current frequency. For example, higher frequency will illuminate more zones. 30
33 8.3 Main Protection Three Minutes Delay at restart for compressor min delay for the 1 st time start-up and 3 minutes delay for others Temperature protection of compressor top Top temp. protector cut off for 30s and restart the compressor with 3 minutes delay Temperature protection of compressor discharge. When the compressor discharge temp. is getting higher, the running frequency will be limited as below rules: ----Compressor discharge temp. T5>115 for 5s, compressor stops <T5<115, decrease the frequency to the lower level every 3 minutes <T5<105, keep running as the current frequency. ----T5<90, cancel the frequency limit control or restart compressor Fan Speed is out of control When indoor fan speed is lower than 300RPM for 50 second, the whole unit stops and LED displays failure, and the error can t resume automatically Inverter module Protection. ----Inverter module protection itself has a protection function against current, voltage and temperature. If these protections happened, the corresponding code will display on indoor unit LED and A/C will stop. The unit will recover 3min delay after the protection disappeared Indoor fan delayed open function ----When the system starts up, the louver will be active immediately and the indoor fan will open 10s later. ----If the system runs in heating mode, the anti-cold wind function has priority Compressor preheating functions. ----Preheating permitting condition: If the main relay closed, T4<3 and the machine is first power on, or T4<3 and compressor has stopped over 3 hours, the compressor heating cable will work. ----Preheating mode: A weak current flows through the coil of compressor from the wiring terminal of compressor, then the compressor is heated without operation. 31
34 ----Preheating release condition: If T4>5 or user turns on the machine and compressor runs, preheating function will stop Crankcase Heater It starts when T4<5 and stops when T4> Operation Modes and Functions Fan only mode. (1) Outdoor fan and compressor stop. (2) Temperature setting function is disabled, and no setting temperature is displayed. (3) Indoor fan can be set to high/med/low/auto. (4) The louver operates same as in cooling mode. (5) The action of auto fan in fan-only mode is the same as auto fan in cooling mode with 24 setting temperature Cooling Mode Compressor running rules: The operation frequency of compressor after starting submits to following rule. 32
35 If users switch on A/C by remote controller, the compressor will run at the Fmax frequency for 7 minutes according to outdoor ambient temp. During the 7 minutes, frequency limitation is active. 7 minutes later, the compressor running frequency will be controlled as below: While Note: Temp.zone A B C D E F G Frequency F8 F8 F7 F6 F5 F3 F1 When T1-Ts keeps in the same temp. zone for 3 minutes, the compressor will run as the below rules: A~E: Increase the frequency to the higher level until to F8. F: Keep the current frequency. G: Decrease the frequency to the lower level until to F1. H: Run at F1 for 1h.(if T1-Ts<-2, compressor will stop) Meanwhile, the compressor running frequency is limited by the current. 33
36 If the current increased more than I2COOL, the frequency will decrease automatically, if the current raise to over I3COOL, the compressor will stop and restart 3min later. During the frequency decreasing, if the current deceased to between I1COOL and I2COOL, the frequency will hold. If the frequency not changed for 3min, the frequency will increase to a higher level, and it can increase twice at most. If the current deceased to lower than I1COOL, the frequency limit will be invalid. Model Current I1COOL I2COOL I3COOL MSV1-09HRDN1-QC2+ MOR-09HDN1-QC MSV1-12HRDN1-QC2+MOR-12HDN1-QC MSV1-18HRDN1-QC2F(D)+ MOC2-18HDN1-QC2 MSV1-18HRDN1-QC2F(E)+ MOC2-18HDN1-QC MSV1-24HRDN1-QC2W+MOF-24HDN1-QC2W MSV1-09HRFN1-ND2E+ MOC-09HDN1-ND2E MSV1-12HRFN1-ND0E+ MOC1-12HFN1-ND0E MSV1-12HRDN1-QC4+ MOC-12HDN1-QC MSV1-09HRDN1-QC8+ MOC-09HDN1-QC MSV1-09HRDN1-QC2(D)+ MOA-09HDN1-QC MSV1-12HRDN1-QC2(D)+ MOB4-12HDN1-QC Outdoor fan running rules: Outdoor fan and compressor start up at the same time, outdoor fan stop 30s delay after the compressor stopped. The outdoor fan have two speeds, it s controlled by T4 as following rules: 34
37 Indoor fan running rules In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto. Auto fan in cooling mode acts as follow: Condenser high temperature T3 protection. When 55<T3<60, the compressor frequency will decrease to the lower level every 3 min until to F1 and then run at F1. When T3<54, the compressor will keep running at the current frequency. When T3<52, the compressor will not limit the frequency again and resume to the former frequency. When T3>60 for 5 seconds, the compressor will stop and restart until T3< Evaporator low temperature T2 protection. When T2<0, the compressor will stop and restart when T2>5. When 0 T2<4, the compressor frequency will limited and decrease to the lower level every minute until stop the compressor. When 4 T2 7, the compressor will keep the current frequency. When T2>7, the compressor frequency will not be limited. 35
38 8.4.3 Heating Mode Compressor running rules: The operation frequency of compressor after starting submits to following rule. After A/C starts up, the compressor will run at the Fmax frequency for 7 minutes according to outdoor ambient temp. During the 7 minutes, frequency limitation is active. 7 minutes later, compressor running frequency will be controlled as below: 36
39 While Temp. zone A B C D E F G Frequency F10 F9 F8 F7 F5 F3 F1 T=0 as default. Note: When T1-Ts keeps in the same temp. zone for 3 minutes, the compressor will run as the below rules: A~E: Increase the frequency to the higher level until to F10. F: Keep the current frequency. G: Decrease the frequency to the lower level until to F1. H: Run at F1 for 1h. (If T1-Ts- T >6, compressor will stop) Meanwhile, the compressor running frequency is limited by the current. If the current increased more than I2HEAT, the frequency will decrease automatically, if the current raise to over I3HEAT,, the compressor will stop and restart 3min later. During the frequency decreasing, if the current deceased to between I1HEAT, and I3HEAT,, the frequency will hold. If the frequency not changed for 3min, the frequency will increase to a higher level, and it can increase twice at most. 37
40 If the current deceased to lower than I1HEAT, the frequency limit will be invalid. Model Current I1HEAT I2HEAT I3HEAT MSV1-09HRDN1-QC2+ MOR-09HDN1-QC MSV1-12HRDN1-QC2+MOR-12HDN1-QC MSV1-18HRDN1-QC2F(D)+ MOC2-18HDN1-QC2 MSV1-18HRDN1-QC2F(E)+ MOC2-18HDN1-QC MSV1-24HRDN1-QC2W+MOF-24HDN1-QC2W MSV1-09HRFN1-ND2E+ MOC-09HDN1-ND2E MSV1-12HRFN1-ND0E+ MOC1-12HFN1-ND0E MSV1-09HRDN1-QC8+ MOC-09HDN1-QC8 MSV1-12HRDN1-QC4+ MOC-12HDN1-QC MSV1-12HRDN1-QC2(D)+ MOB4-12HDN1-QC2 MSV1-09HRDN1-QC2(D)+ MOA-09HDN1-QC Outdoor fan running rules: Outdoor fan and compressor start up at the same time, outdoor fan stop 30s delay after the compressor stopped. The outdoor fan have two speeds, it s controlled by T4 as following rules: Indoor fan running rules: The indoor fan speed can be selected as high, medium, low and auto, the anti-cold-wind function has the priory. If reached the set temperature, the indoor fan transfers to lowest speed, the anti-cold wind function has the priory. If operation mode transferred or compressor restarted, indoor fan works in setting fan speed. Anti-cold-wind function control principle: 38
41 For 9K,12K,18K units For 24K unit Auto fan action in heating mode Defrosting mode: Conditions of defrosting: Condition 1: If T4>0, When the units are running, if any one of the following conditions is satisfied, the unit starts defrosting: 1 If the accumulated time of the unit working within T3<3reached 40 minutes and T3 keeps lower than -6 over 3 minutes. 2 If the accumulated time of the unit working within T3<3reached 80 minutes and T3 keeps lower 39
42 than -4 over 3 minutes. Condition 2: If T4<0, If satisfied any item of the condition 1 and the T2 temperature has decreased 5, starts defrosting. Note: T2 is the maximum value of the evaporator temperature during the anti-cold wind function. It s recorded by the system automatically. Condition 3: No matter what value T4 is, if the accumulated time of the unit working within T3<3reached 120 minutes and T3 keeps lower than -2 over 3 minutes, starts defrosting. Condition of ending defrosting: If any one of following items is satisfied, defrosting will stop and the machine will turn to normal heating mode. 1 T3 >TCDE1. Model TCDE1 ( ) MSV1-09HRDN1-QC2+ MOR-09HDN1-QC2 MSV1-12HRDN1-QC2+MOR-12HDN1-QC2 MSV1-09HRFN1-ND2E+ MOC-09HDN1-ND2E MSV1-12HRFN1-ND0E+ MOC1-12HFN1-ND0E MSV1-09HRDN1-QC8+ MOC-09HDN1-QC8 12 MSV1-12HRDN1-QC4+ MSV1-12HRDN1-QC4 MSV1-09HRDN1-QC2(D)+ MOA-09HDN1-QC2 MSV1-12HRDN1-QC2(D)+ MOB4-12HDN1-QC2 MSV1-18HRDN1-QC2F(D)+ MOC2-18HDN1-QC2 MSV1-18HRDN1-QC2F(E)+ MOC2-18HDN1-QC2 15 MSV1-24HRDN1-QC2W+MOF-24HDN1-QC2W 12 2 T3>8 and remains for 80 seconds. 3 The defrosting time lasts 10min. 40
43 Defrosting action: For MSV1-24HRDN1-QC2W, MSV1-18HRDN1-QC2FD, MSV1-18HRDN1-QC2F(E) Model FD FD1 MSV1-18HRDN1-QC2F(D)+MOC2-18HDN1-QC MSV1-18HRDN1-QC2F(E)+ MOC2-18HDN1-QC2 MSV1-24HRDN1-QC2W+MOF-24HDN1-QC2W For MSV1-09HRDN1-QC2, MSV1-12HRDN1-QC2, MSV1-09HRFN1-ND2E, MSV1-12HRFN1-ND0E, MSV1-09HRDN1-QC8, MSV1-12HRDN1-QC4, MSV1-09HRDN1-QC2(D), MSV1-12HRDN1-QC2(D) 41
44 High evaporator coil temp.t2 protection: (1) T2> TEH2, compressor running frequency decreases to the lower level every 20s. If the frequency decreased to F2 and the T2 still over TEH2 for 3 minutes, the compressor will stop. If T2 deceased to lower than 48, or 48<T2< TEH2 last for 6 minutes, release the frequency limit control. (2) If T2>60, stop the compressor and restarts until T2<48. Model TEH2( ) MSV1-09HRDN1-QC2+ MOR-09HDN1-QC2 MSV1-12HRDN1-QC2+MOR-12HDN1-QC2 MSV1-18HRDN1-QC2F(D)+MOC2-18HDN1-QC2 MSV1-18HRDN1-QC2F(E)+ MOC2-18HDN1-QC2 MSV1-09HRFN1-ND2E+MOC-09HDN1-ND2E 53 MSV1-12HRFN1-ND0E+ MOC1-12HFN1-ND0E MSV1-09HRDN1-QC8+MOC-09HDN1-QC8 MSV1-12HRDN1-QC4+ MOC-12HDN1-QC4 MSV1-09HRDN1-QC2(D)+ MOA-09HDN1-QC2 MSV1-12HRDN1-QC2(D)+ MOB4-12HDN1-QC2 MSV1-24HRDN1-QC2W+MOF-24HDN1-QC2W Auto-mode This mode can be chosen by remote controller and the setting temperature can be changed between 17~30. In auto mode, the machine will choose cooling, heating or fan-only mode according to the difference between T1 and Ts. T1-Ts T1-Ts>1 Running mode Cooling -1< T1-Ts 1 Fan-only T1-Ts -1 Heating Indoor fan will run in auto fan of the relevant mode. The louver operates the same as in relevant mode. If the machine switches mode between heating and cooling, the compressor will keep stopping for 15 minutes and then choose the mode according to T1-Ts again. If the setting temperature is modified, the machine will choose the running function again. 42
45 8.4.5 Dehumidify mode Indoor fan speed is fixed in breeze and can t be changed. The louver angle is the same as in cooling mode Compressor running rules Room over low temperature protection If room temperature is lower than 10, compressor will stop and not resume until room temperature over Evaporator anti-freezing protection, condenser high temperature protection and outdoor unit frequency limit are valid, and they are the same as that in cooling mode The outdoor fan operates same as in cooling mode Forced operation function Enter forced operation function: Pressing the touch button once, the machine will transfer into forced auto mode, if pressing the button once again, the machine will turn into forced cooling mode, the third pressing will stop the unit, and the forth pressing is the start of the cycle of forced auto mode, forced cooling mode and stop. Refer the following chart: In forced operation mode, all general protections and remote control are available Operation rules: Forced cooling mode: The compressor runs at F2 frequency and indoor fan runs as breeze. After running for 30 minutes. the 43
46 machine will turn to auto mode as 24 setting temperature. Forced auto mode: The action of forced auto mode is the same as normal auto mode with 24 setting temperature Timer function Timing range is 24 hours, and the minimum resolution is 15 minutes Timer on. After turning off, the machine will turn on automatically when reaching the setting time Timer off. After turning on, the machine will turn off automatically when reaching the setting time Timer on/off. After turning off, the machine will turn on automatically when reaching the setting on time, and then turn off automatically when reaching the setting off time Timer off/on. After turning on, the machine will turn off automatically when reaching the setting off time, and then turn on automatically when reaching the setting on time The setting time is relative time The tolerance of timer is 1 minute per hour Sleep function mode Operation time in sleep mode is 7 hours. After 7 hours the AC quits this mode and turns off Operation process in sleep mode is as follow: After pressing ECONOMIC or SLEEP button on controller, the machine will turn into sleep mode. When cooling, the setting temperature rises 1(be lower than 30) every one hour, 2 hours later the setting temperature stops rising and indoor fan is fixed as low speed. When heating, the setting temperature decreases 1(be higher than 17) every one hour, 2 hours later the setting temperature stops decreasing and indoor fan is fixed as low speed.(anti-cold wind function has the priority) Timer setting is available When user uses timer off function in sleep mode(or sleep function in timer off mode), if the timing is less than 7 hours, sleep function will be cancelled when reaching the setting time. If the timing is more than 7 hours, the machine will not stop until reaches the setting time in sleep mode. 44
47 8.4.9 Auto-Restart function The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart module. In case of a sudden power failure, the module memorizes the setting conditions before the power failure. The unit will resume the previous operation setting (not including Swing function) automatically after 3 minutes when power returns. If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30 minutes and turn to auto mode as 24 setting temp. If A/C is off before power off and A/C is required to start up now, the compressor will have 1 minutes delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts Automatic panel function The automatic panel is forced to turn to the closing direction at an angle of 50 when the unit is getting through the power, and this action is not affected by any signal from remote controller When the unit is turned on, the panel is opened automatically at an angle of 50, then the horizontal louver will be opened When the unit is turned off, the panel is closed automatically at an angle of 50, then the horizontal louver will be closed If the panel needs moving when the horizontal louver is in action, the unit will stop the horizontal louver and then carry out the action of the panel. After ending the action of the panel, the horizontal louver will continue its action Ionizer (Clean Air) function Clean Air function is available only when the A/C is on, and it s controlled through remote controller After the A/C being turned on, the Clean Air function is switched on when the A/C receives FRESH CODE at first time, and ionizer is switched off when the A/C receives the CODE again. It s a circle After starting the Clean Air function, the ionizer can work only when the indoor fan motor is running. If the indoor fan motor is off, the ionizer also stops working, even though the Clean Air function is available Switching the running mode will not stop the ionizer. When turning off the A/C, the ionizer is 45
48 also turned off. 46
49 9. Troubleshooting 9.1 Indoor Unit Error Display Display E0 E1 E2 E3 E5 E6 E7 P0 P1 P2 P4 LED STATUS EEPROM parameter error Indoor / outdoor units communication protection Zero-crossing signal error Indoor fan speed out of control Open or short circuit of outdoor temperature sensor Open or short circuit of room or evaporator temperature sensor Outdoor fan speed out of control IBM malfunction or IGBT over-strong current protection Over voltage or too low voltage protection Temperature protection of compressor top. Inverter compressor drive error Note: E4 & P3: Reserved function 47
50 9.2 Diagnosis and Solution EEPROM parameter error diagnosis and solution Shut off the power supply and turn on it 5s later Replace indoor PCB The problem comes out again Is the EEPROM chip plugged in indoor PCB well? No Correct the connection Replace the main PCB of indoor unit 48
51 9.2.2 Indoor / outdoor units communication protection error diagnosis and solution Turn off the power supply, after 1 minute, connect the power supply, turn on the unit with remote controller The unit does not work normally. Check the wiring between indoor and outdoor unit. Is the connection of L, N, S and GND good? No Reconnect and retest Yes Is the LED4(red) bright and LED1(yellow) blinking on outdoor PCB? Yes Replace indoor PCB and repower No The unit does not work normally. The power supply for outdoor PCB is fail. Check the wiring on outdoor PCB comparing with wiring plate. Is the connection good? Yes Replace outdoor e-box. No Correct the connection. 49
52 9.2.3 Fan speed out of control diagnosis Shut off the power supply and turn on it 5s later The unit does not work normally Turn off the unit, rotate the cross fan. Does it rotate freely? Yes No Disassemble the connection between fan and motor, check if the bearing is normal. If not, change the bearing.if yes, follow the below step. Is the fan motor connector and connection good? Yes Is the voltage being applied to the fan motor? Yes Replace the fan motor No Replace the PCB Open or short circuit of temperature sensor diagnosis and solution. Check the connections between the sensors and the PCB. Are the connections good? Yes Replace the sensor and check if the errors happen again? Yes Replace outdoor PCB 50
53 9.2.5 IGBT over-strong current protection diagnosis and solution. Check whether the connections between outdoor PCB and IPM are good? Yes Check whether the IPM is fixed to radiator tightly No Fastening the IPM to the radiator Replae the IPM The unit does not work normally Replace the compressor Over voltage or too low voltage protection diagnosis and solution. Is the power supply good? No Make sure the power supply is normal. Yes Replace the outdoor e-box High temperature protection of compressor top diagnosis and solution. Does compressor operate? No Is the connection good? No Reconnect it Yes Yes Is refrigerant circulation volume normal? Is protector normal? No Replace it No, Charge refrigerant Yes Is abnormality the same after gas charging? Replace the outdoor PCB. There is block(such as capillary or welded points of the pipes.) 51
54 9.2.8 Inverter compressor drive error diagnosis and solution. Is the connection of compressor good? Is the wiring sequence right? The voltage range proper? No Reconnect and retry Yes Replace the outdoor PCB No Replace inverter compressor Zero crossing detection error This is alarm signal when the main chip can t detect over-zero signal. When such failure occurs, the main control board must have fault. 52
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES
RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3.
9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE
9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 9 3.1 Indoor
WALL MOUNTED AIR CONDITIONER SERVICE MANUAL 11M INVERTER
WALL MOUNTED AIR CONDITIONER SERVICE MANUAL 11M INVERTER This manual applies to the models: 42HVM109303 / 38HVM109303(P) 42HVM112303 / 38HVM112303(P) 42HVM118303 / 38HVM118303(P) 42HVM124303 / 38HVM124303(P)
Technical service manual 2009
MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features
SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/
SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the
SERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type. FSAI-Pro-91AE2 / FSOAI-Pro-91AE2. FSAI-Pro-241AE2 / FSOAI-Pro-241AE2
SERVICE MANUAL Room Air Conditioner Split Wall-Mounted Type FSAI-Pro-91AE2 / FSOAI-Pro-91AE2 FSAI-Pro-121AE2 / FSOAI-Pro-121AE2 FSAIF-Pro-181AE2 / FSOAIF-Pro-181AE2 FSAI-Pro-241AE2 / FSOAI-Pro-241AE2 NOTE:
Split Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE MSV1-09HRDN1-QC2(A) MSV1-12HRDN1-QC2(A)
SERVICE MANUAL MIDEA AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE MSV1-09HRDN1-QC2(A) MSV1-12HRDN1-QC2(A) V1.2 Oct, 2007 CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2.
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
WYS SERIES SPLIT 3D DC INVERTER HEAT PUMP / AIR CONDITIONER SERVICE MANUAL
z WYS SERIES SPLIT 3D DC INVERTER HEAT PUMP / AIR CONDITIONER SERVICE MANUAL Revision A: 151110001, Content updated. Model Numbers: 17 SEER Family: WYS009AMFI17RL, WYS012AMFI17RL, WYS009GMFI17RL, WYS012GMFI17RL,
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
Room Air Conditioners
User Manual Room Air Conditioners R410A Split Type Y Series DC INVERTER ECO940SD ECO120SD ECO1840SD Please read this installation manual completely before installing the product. When the power cord is
R410A SPLIT SERIES DC INVERTER
R40A SPLIT SERIES DC INVERTER Models ECO905SINV ECO205SINV ECO805SINV Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit
Troubleshooting 13. Troubleshooting Indoor unit s LED indication of Corona DC inverter unit MCAC-HTSM-2007-11 E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P5 EEPROM error outdoor communication error Zero-crossing examination
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Service Manual S 3325 S 3331 S 3348
Service Manual S 3325 S 3331 S 3348 CONTENTS 1. Precaution... 3 1.1 Safety Precaution... 3 1.2 Warning... 3 2. Function... 7 3. Dimension... 8 3.1 Indoor Unit... 8 3.2 Outdoor Unit... 10 4. Refrigerant
Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how to
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
Split Air Conditioner
Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1
LG Floor Standing-Type Air Conditioner OWNER'S MANUAL
website http://www.lgservice.com LG Floor Standing-Type Air Conditioner OWNER'S MANUAL LG ENGLISH FRANÇAIS ITALIANO ESPAÑOL ESPAÑOL FRANÇAIS DEUTSCH IMPORTANT Please read this owner's manual carefully
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
Inverter Single Zone Ductless Mini Split Heat Pump
WNER S MANUAL Inverter Single Zone Ductless Mini Split Heat Pump VMH 30/36 Series Version C Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com wner s Manual
Operating Instructions Air Conditioner
P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O
SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE TAS-18MVHN/O TAS-27MVHN/O TAS-36MVHN/O DC MULTI OUTDOOR UNITS CONTENTS 1. General information of Outdoor Units... 3 2. Dimensions... 4 3. Wiring Diagram...
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
LG Multi Type Air Conditioner
LG Multi Type Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
Service manual. Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR
Service manual Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR Climatic Control Corporation Wall-Mounted Split Type Content 1. Precaution 1 1.1
10.1 Indoor Unit Error Display
10.1 Indoor Unit Error Display Display E0 E1 E2 E3 E5 E6 P0 P1 P2 P4 LED STATUS EEPROM parameter error Indoor / outdoor units communication protection Zero-crossing signal error Fan speed out of control
Technical service manual
GD Midea Refrigeration Equipment Co.,Ltd ODMI-A-1202 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual R410A Multi DC inverter 220~240V-1Ph-50Hz Outdoor units Models M2OC-14HRDN1 M2OC-14HRDN1-Q
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.
OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL67657205 www.lg.com ITALIANO ESPAÑOL FRANÇAIS
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
LG Room Air Conditioner OWNER'S MANUAL
website http://www.lg.ca LG Room Air Conditioner OWNER'S MANUAL LG Prior to installation, this airconditioning unit must be submitted for approval by the utility service which provides electricity (EN
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. www.lg.
ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Room Air Conditioner P/NO : 3828A20434H www.lg.com
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Wall Mounted Mini Split Heat Pump Air Conditioner
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
ROOM AIR CONDITIONER INSTALLATION MANUAL
ROOM AIR CONDITIONER INSTALLATION MANUAL ( Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE
Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
LG Wireless Remote Controller
Visit us at : http://www.lgservice.com LG Wireless Remote Controller Owner's & Installation Manual Models: PQWRHSF0 PQWRCSF0 LG ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH IMPORTANT Please read this installation
INDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-60YHA/RAC-60YHA OUTDOOR UNIT INDOOR UNIT RAC-60YHA RAS-60YHA Instruction manual Page 1~26 To obtain the best performance and ensure years of
Heat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t. www.ice-air.com
80 Hartford Avenue Mount Vernon New York 10553 Tel: 914-668-4700 EXT. 203 Fax: 914-668-5643 www.ice-air.com Wo r l d C l a s s C o m f o r t Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE
Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
AIR CONDITIONER (SPLIT TYPE)
OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use ENGLISH EN Indoor Unit RAS-07PKVP-E RAS-10PKVP-E RAS-13PKVP-E RAS-16PKVP-E RAS-18PKVP-E RAS-07PKVP-ND RAS-10PKVP-ND RAS-13PKVP-ND RAS-16PKVP-ND
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit
OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24 Wall Mounted Unit CONTENTS SAFETY PRECAUTIONS Warning...3 Caution...4. NAMES OF PARTS Indoor unit......5 outdoor unit...5 Indication lamp...5 OPERATING
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
Split Air Conditioner
Change for Life Split Air Conditioner Owner's Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD
Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify
Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E
AIR CONDITIONER (SPLIT TYPE) Owner s Manual Indoor Unit Model name: For commercial use 4-way Cassette Type RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E Owner s Manual English
AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL
ENGLISH FRANÇAIS ESPAÑOL OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED P/NO : MFL63288101 www.lge.com
AIR CONDITIONER OWNER S MANUAL. ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πãõ PORTUGUÊS NEDERLANDS
OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. Type : Floor Standing Type(Console) www.lg.com ENGLISH ITALIANO ESPAÑOL FRANÇAIS
SYSTEM Inverter Air Conditioners
OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place
The figures in this manual may be different with the material objects, please refer to the material objects for reference.
CONTENTS Operation and maintenance Notices for operation Notices for use Names and functions of each part Operation of wireless remote control Emergency operation Clean and care Troubleshooting Installation
LG Floor Standing Type Air Conditioner INSTALLATION MANUAL
website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG IMPORTANT Please read this installation manual completely before
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
and using this appliance and keep this manual for future reference.
Thank you very much for purchasing this Air Conditioner. Please read this use and installation instructions carefully before installing and using this appliance and keep this manual for future reference.
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to