1 Make the Right Connection Electrosurgical & Smoke Evacuation Products
2 Electrosurgical & Smoke Evac Products ELECTROSURGICAL PRODUCTS DeRoyal proudly presents the highest quality and broadest selection of cautery pencils, electrodes, grounding pads, and smoke evacuation products for the surgical market. All DeRoyal Electrosurgical Products are indemnified for use with all ESU generators that are available. TABLE OF CONTENTS ELECTROSURGICAL PENCILS Hand-Activated Electrosurgical Pencils 3 Breazeale Fine Touch Electrosurgical Pencil 4 Suction Coagulators 5 ELECTRODES Single-Use Electrodes 6 PTFE Coated Laprascopic Electrodes 7 SPECIALTY ELECTRODES Micro Needles 8 LLETZ Electrodes 8 Bayonet Electrodes 9 ARTHROSCOPIC ELECTRODES Arthroscopic Electrodes 9 DISPERSIVE ELECTRODES Hydrogel & Adhesive Gel Dispersive Electrodes 10 PAGE SMOKE EVACUATION SYSTEMS & PRODUCTS PAGE Crystal Vision Smoke Evacuation Machine ExtendEVAC Smoke Evacuation Pencils and Attachments 15 Smoke Evacuation Machine Filters and Adapters Universal Smoke Evacuation Attachments and Accessories 18 Smoke Evacuation Tubing & Accessories for Laparoscopic or Laser Procedures 19 ILLEGAL RESTRAINTS OF TRADE 20 DEROYAL CUSTOMER INDEMNIFICATION POLICY 20 DISCLAIMER 20 ELECTROSURGICAL ESSENTIALS Electrode Tip Cleaner 11 Disposable Bipolar Cord 11 All DeRoyal smoke evacuation products are available bulk non-sterile by deleting zeros after the dash and adding an NS to the end of any product number. DeRoyal products may be covered by one or more of the following U.S. or Foreign patents 5,693,044, 5,431,650, 5,318,516, 5,199,944, 5,108,389, EP , , 6,099,525, 6,142,995, 6,458,125B1, and D501, 047S. Other U.S. and/or foreign patents may be pending. 2
3 Make the Right Connection ELECTROSURGICAL PENCILS Hand-Activated Electrosurgical Pencils Reliability at your fingertips Three-prong plug fits most electrosurgical generators Flexible 10 cord for easy set up and drapeability Universal chuck accommodates C\cx electrode Yellow and blue color-coded switch with audible and tactile feedback to confirm activation and identify cut/coag controls Fluid-proof textured barrel prevents slipping or shock New versions available with PTFE coated electrodes that reduce tissue adhesion Product No. Description OEM OEM Sterile Sterile Non-Sterile Non-Sterile Uncoated PTFE Coated Uncoated PTFE Coated Rocker Switch Pencil Button Switch Pencil Rocker Switch Pencil w/holster Button Switch Pencil w/holster Rocker Switch Pencil w/15 Cord, Holster Button Switch Pencil w/15 Cord, Holster Rocker Switch Pencil w/holster, Tip Cleaner Button Switch Pencil w/holster, Tip Cleaner Holster Button Switch Pencil w/1 ENT Blade, Holster Button Switch Pencil w/1 Needle, Holster All packaged Sterile, 1/Pk, 25 Pks/Bx, 2 Bxs/Cs. All Non-Sterile pencils are 100/Cs, holster sold separately. Geo-Med catalog numbers for PTFE Pencil now available by adding a G to end of product number (i.e G). 3
4 Electrosurgical & Smoke Evac Products ELECTROSURGICAL PENCILS Side view of ergonomic forward-weighted design of the Breazeale pencil (top) compared with a regular electrosurgical pencil (below). Breazeale Fine Touch Electrosurgical Pencil Revolutionary design moves rocker switch placement closer to the electrode for much finer control when cutting or cauterizing tissue Designed by a Plastic Surgeon specifically for plastic surgery for precise results Pencil is weighted forward for greater control and accuracy The ergonomic design allows for even greater tip control and comfort Available pre-loaded with the most common electrodes used by plastic surgeons Universal connection cord fits all generators A top view showing the forward switch placement of the Breazeale pencil (top) for precise control compared with the set-back switch placement of a regular pencil (below). Product No. Description Sterile Sterile Sterile Uncoated PTFE Coated Uncoated* 88-FT31 88-FT41 Rocker Switch Pencil 88-FT01 88-FT21 88-FT0110 Rocker Switch Pencil w/holster 88-FT51 Rocker Switch Pencil w/holster, Tip Cleaner 88-FT12 88-FT12C Rocker Switch Pencil w/1 Needle, Holster 88-FT FT10310 Rocker Switch Pencil w/micro Needle, Holster 88-FTM13 88-FTM13C Rocker Switch Pencil w/1 ENT Blade, Holster 88-FTM12 88-FTM12C Rocker Switch Pencil w/1 ENT Needle, Holster All packaged 1/Pk, 25 Pks/Bx, 2 Bxs/Cs unless otherwise noted. For Non-Sterile number, add NS to sterile part number, 100/Cs. Holster sold separately. * Packaged 1/Pk, 10 Pks/Bx, 1 Bx/Cs. 4
5 Make the Right Connection ELECTROSURGICAL PENCILS Suction Coagulators Two functions, one instrument Increased efficiency during procedures requiring controlled fluid evacuation Facilitates precise electrosurgical coagulation Suction and coagulation can be performed independently or simultaneously Foot switching or hand switching coag activation to accommodate preferences Vented handle for suction control Handle ergonomically designed to provide a sure grip when wet and improve tactile sensitivity. Flexible configuration allows clinician to match instruments to specific surgical need Product No. Description KW FR Suction Coagulator w/hand Switch Activation FR 10FR Suction Coagulator w/foot Switch Activation All Packaged Sterile, 1/Pk, 10 Pks/Cs. 5
6 Electrosurgical & Smoke Evac Products ELECTRODES A B C D E F G H I J K L M N O P Single-Use Electrodes Convenience that is cost effective PTFE coated electrodes reduce tissue adhesion Product offering includes most widely used blades, needles, and ball electrodes available for specific applications Available in regular and extended lengths to access deep cavities ENT/Modified versions available in coated or stainless steel Product No. Description Uncoated PTFE Coated Uncoated ENT/Modified PTFE Coated ENT/Modifed (E) (F) M13 (M) C M13C 1 Blade Electrode (G) (H) M12 (L) C (K) M12C 1 Needle Electrode (A) (B) M11 (P) C M11C 6 Blade Electrode (C) (D) M10 (O) C M10C 6 Needle Electrode (N) C 4 Blade Electrode (I) (J) C 3 /16 Ball Electrode C 1 Blade for ExtendEVAC Pencil C 1 Needle for ExtendEVAC Pencil All Packaged Sterile, 1/Pk, 25 Pks/Cs. OEM Availability: For Non-Sterile number, replace the initial 0 after dash with 1, i.e C, 100/Cs. Geo-Med PTFE coated electrodes now available by adding a G to end of product number (i.e CG). 6
7 Make the Right Connection ELECTRODES PTFE Coated Laparoscopic Electrodes New PTFE coated electrodes for reduced tissue adhesion Product offering that includes most widely used tips and lengths for specific applications Helps provide excellent dissection and coagulation Fully insulated shaft prevents stray current and unwanted burns Disposable, convenient, and cost-effective Product No. Description Stem Qty Standard Blade, 33 cm (14.2 ) Pencil 6/Bx Round Spatula, 33 cm (14.2 ) Pencil 6/Bx Curved Spatula, 33 cm (14.2 ) Pencil 6/Bx S Curved Spatula, 33 cm (14.2 ) Split 6/Bx L Curved Spatula, 45 cm (17.7 ) Pencil 6/Bx LS Curved Spatula, 45 cm (17.7 ) Split 6/Bx L Hook, 33 cm (14.2 ) Pencil 6/Bx S L Hook, 33 cm (14.2 ) Split 6/Bx L L Hook, 45 cm (17.7 ) Pencil 6/Bx LS L Hook, 45 cm (17.7 ) Split 6/Bx J Hook, 33 cm (14.2 ) Pencil 6/Bx S J Hook, 33 cm (14.2 ) Split 6/Bx L J Hook, 45 cm (17.7 ) Pencil 6/Bx LS J Hook, 45 cm (17.7 ) Split 6/Bx Needle, 33 cm (14.2 ) Pencil 6/Bx S Needle, 33 cm (14.2 ) Split 6/Bx Ball, 33 cm (14.2 ) Pencil 6/Bx L Wire, 33 cm (14.2 ) Pencil 6/Bx S L Wire, 33 cm (14.2 ) Split 6/Bx L L Wire, 45 cm (17.7 ) Pencil 6/Bx LS L Wire, 45 cm (17.7 ) Split 6/Bx J Wire, 33 cm (14.2 ) Pencil 6/Bx S J Wire, 33 cm (14.2 ) Split 6/Bx OEM Availability: Add NS to the end of the part number for Non-Sterile items, 100/Cs. ELECTRODE TIP STYLES STEMS Round Spatula Curved Spatula L Hook J Hook Needle L Wire J Wire Pencil Stem Split Stem 7
8 Electrosurgical & Smoke Evac Products SPECIALTY ELECTRODES DeRoyal s line of premium electrodes offers cost effective and high quality for use during your specialty arthroscopic and plastics procedures. Micro Needles Precision in cutting and coagulation without the expense of a laser Ultra-sharp tip allows use of extremely low wattage Tungsten tip for heat resistance Insulated within 3 mm of tip to allow deep tissue access without the risk of accidental burns Product No. Description Quantity cm Micro Needle 10/Cs A 4cm Micro Needle Electrode 10/Cs A 2cm Micro Needle w/3 mm 45º Angle 10/Cs A 3cm Micro Needle w/3 mm 45º Angle 10/Cs Micro Needle w/45º Angle 10/Cs OEM Availability: Add NS to the end of the above product numbers for Non-Sterile items, 100/Cs. LLETZ Electrodes Wire loop tungsten electrodes Greater precision and durability than stainless steel Resists breakage at higher generator levels Excellent stability against flexing or bending during surgical use Quality loops that minimize thermal damage and present good histopathology specimens Ideal for outpatient or office surgery Available in a variety of loop sizes Product No. Description Quantity mm x 10 mm LLETZ Loop Electrode 10/Cs mm x 12 mm LLETZ Loop Electrode 10/Cs mm x 12 mm LLETZ Loop Electrode 10/Cs mm x 15 mm LLETZ Loop Electrode 10/Cs mm Diameter LLETZ Ball Electrode 10/Cs mm Diameter LLETZ Ball Electrode 10/Cs mm x 5 mm LLETZ Square Loop Electrode 10/Cs mm x 4 mm LLETZ Square Loop Electrode 10/Cs mm x 8 mm LLETZ Square Loop Electrode 10/Cs Add NS to the end of the above products for Non-Sterile items, 100/Cs. 8
9 Make the Right Connection SPECIALTY ELECTRODES Bayonet Electrodes Tungsten steel electrodes Does not bend or break under extreme power levels Insulated shaft protects against accidental tissue burns Ideal for neurological and orthopedic spinal procedures Product No. Description Quantity mm Loop Bayonet Electrode 10/Cs mm Loop Bayonet Electrode 10/Cs mm Loop Bayonet Electrode 10/Cs mm Loop Bayonet Electrode 10/Cs mm Ball Bayonet Electrode 10/Cs mm Needle Bayonet Electrode 10/Cs Add NS to the end of the above products for Non-Sterile items, 100/Cs. ARTHROSCOPIC ELECTRODES Arthroscopic Electrodes For use in arthroscopic procedures where irrigating solutions are used in conjunction with an electrosurgical pencil Insulation extending to the electrode tip for precise energy delivery Transparent insulation improves surgeon s tip visualization Stabilizing electrode cap ensures a safe connection from electrode to pencil Compatible with all pencils for ease of conversion 6 Z\x (16.51 cm) length Product No. Description Quantity Insulated Arthroscopic Hook Electrode, 90 Degree Angle 10/Cs Insulated Arthroscopic Hook Electrode, 45 Degree Angle 10/Cs Insulated Arthroscopic Angled Blade Electrode, 90 Degree Angle 10/Cs Arthroscopic Angled Blade Electrode, 90 Degree Angle 10/Cs Rocker Pencil w/ Electrode 10/Cs Rocker Pencil w/ Electrode 10/Cs Rocker Pencil w/ Electrode 10/Cs Rocker Pencil w/ Electrode 10/Cs Push Button Pencil w/ Electrode 10/Cs Push Button Pencil w/ Electrode 10/Cs Push Button Pencil w/ Electrode 10/Cs Push Button Pencil w/ Electrode 10/Cs 9
10 Electrosurgical & Smoke Evac Products DISPERSIVE ELECTRODES FlexiPad Hydrogel and Adhesive Gel Dispersive Electrodes Strong adhesion, yet gentle removal Standard plugs work with most electrosurgical generators Flexible 10 cord for easy set up and drapeability Impermeable foam backing and non-conductive adhesive border securely seal out fluids creating a moisture-safe barrier Thin, flexible hydrogel, or adhesive gel pads conform to a variety of anatomical sites and allows easy removal without pulling hair or injury to skin New FlexiPad has unique shape and advanced hydrogel to better conform and adhere to body contours Product No. Description FlexiPad Adhesive Gel Hydrogel Adult Mono/Standard Pad Adult Dual Conductor Pad Adult Dual Conductor Pad w/15 Cord Pediatric Dual Conductor Pad All packaged Non-Sterile, 1/Pk, 50 Pks/Bx, 1 Bx/Cs. 10
11 Make the Right Connection ELECTROSURGICAL ESSENTIALS Electrode Tip Cleaner A convenient debris removal system Coated scratch pad eliminates disruptive scraping of electrodes or instruments for quick and easy cleaning of instrument tips Raypaque element ensures x-ray detectability Adhesive backing securely holds on draped surface Product No. Description Quantity x 2 Tip Cleaner 1/Pk, 25 Pks/Bx, 4 Bxs/Cs x 2 Tip Cleaner 1/Pk, 240 Pks/Cs OEM Availability: For Non-Sterile number, add NS, 1000/Cs. Disposable Bipolar Cord For use in conjunction with ophthalmic/neurosurgical microsurgical bipolar forceps Product No. Description Quantity Bipolar Cord, Sterile 1/Pk, 10 Pks/Cs OEM Availability: For Non-Sterile number, replace the initial 0 with 1 after dash, 100/Cs. 11
12 Electrosurgical & Smoke Evac Products SMOKE EVACUATION SYSTEMS & PRODUCTS Crystal Vision Smoke Evacuation Machine ADVANTAGES FOR OPEN PROCEDURES Hands free smoke evacuation With Crystal Vision, you can choose to use our ExtendEVAC pencil with integral telescoping tip or a regular electrocautery pencil snapped into our convenient smoke evacuator sheath for complete elimination of smoke from the O.R. Both can be conveniently held in one hand by the surgeon, with the evacuator conveniently located for ease of use. ULPA filtration and sensors Crystal Vision s built-in sensors prevent smoke particles from infiltrating the operating room by alerting the operator when ULPA filter is full and stopping the machine automatically if not changed within a few minutes. Easy-to-read console The front panel of Crystal Vision illuminates automatically when room lights are lowered, with red light indicators for high flow and green for low flow. ESU Sensor The unit automatically activates when the pencil is activated and stops when the pencil is deactivated for efficient, quiet operation. ADVANTAGES FOR LASER PROCEDURES Meet OSHA Guidelines OSHA has stated that all surgical smoke produced by lasers should be properly filtered by a smoke evacuation system as close to the surgical site as possible. Laser Footswitch Sensor The footswitch sensor will automatically activate smoke evacuation once the laser is active. Additional Procedures Speculum tubing allows the evacuation of smoke for GYN and ENT removal of nodes, growths and genital warts. Our laser tubing has a male barb that fits perfectly over the smoke evacuation port on most speculums. Occlusion Light The Crystal Vision Machine will alert you for any obstructions within the speculum port or tubing during the procedure. Across-The-Board Safety Using our smoke evacuation system will ultimately remove the toxic smoke to reduce the chance of viral airborne transfer. 12
13 Make the Right Connection SMOKE EVACUATION SYSTEMS & PRODUCTS ADVANTAGES FOR LAPAROSCOPIC PROCEDURES Clinically superior Crystal Vision automatically removes CO2 gas from abdomen post-procedure reducing postoperative pain by reducing the CO2 trapped inside patient at the end of the procedure. Patient s body will absorb less CO2, producing better patient outcomes by reducing recovery time and medication required post-operatively. The laparoscopic smoke evacuation tubing set conveniently attaches directly to secondary trocar stopcock and is virtually invisible to the physician so it does not change current laparoscopic technique.. Constant monitoring of pneumoperitoneal pressure With Crystal Vision, the amount of internal pneumoperitoneal pressure is constantly assessed and automatically reduced when needed to lower potentially dangerous pressure levels. Increases patient comfort By eliminating the CO2 gas, Crystal Vision can eliminate patient discomfort usually associated with remaining gas pockets post-operatively Low flow range Unique to Crystal Vision is its low flow range that is easily adjusted to match the in-flow rate of the insufflator, helping maintain pneumoperitoneal pressure and freeing the surgeon to concentrate on the procedure. Automatic tissue protection response The Crystal Vision pump stops automatically if tissue is accidentally suctioned to minimize potential trauma. Eliminates smoke back-flow into patient With Crystal Vision, clean CO2 gas maintains internal pressure inside the patient, so that smoke is not allowed to infiltrate the surgical site. Manual activation capability Crystal Vision can be manually activated to remove intra-abdominal gases at the end of procedures, eliminating the need to apply hand pressure to the patient s abdomen. Shut-off is automatic when complete. During surgical procedures using laser or electrosurgical unit, the thermal destruction of tissue creates a smoke byproduct. Research studies have confirmed that this smoke plume can contain toxic gases and vapors such as benzene, hydrogen cyanide, and formaldehyde, bioaerosols, dead and live cellular material (including blood fragments), and viruses. At high concentrations, the smoke causes ocular and upper respiratory tract irritation in health care personnel, and creates visual problems for the surgeon. The smoke has unpleasant odors and has been shown to have mutagenic potential. -- Center for Disease Control and Prevention, U.S. Department of Health and Human Services National Institute for Occupational Safety and Health. NIOSH Hazard Controls, Control of Smoke From Laser/Electric Surgical Procedures, September,
14 Electrosurgical & Smoke Evac Products SMOKE EVACUATION SYSTEMS & PRODUCTS Crystal Vision Smoke Evacuation Machine For use with open and laparoscopic procedures Advanced smoke evacuation unit with the quality, stamina and affordability The clear choice for maximized smoke elimination in the O.R. Non-sterile Product No. Uncoated Description Quantity D Model 350D Crystal Vision Smoke Evacuation Unit w/esu Sensor for Open & Laparoscopic Procedures Model 360 Crystal Vision Smoke Evacuation Unit w/esu Sensor for Open Procedures Only 1/Cs 1/Cs SPECIFICATIONS - MODEL 360, 350-D Size: 7.25 H x 14.0 W x 15.0 D Weight: Less than 17 pounds Power Requirements: V.A.C., single phase, Hz, 2.5 amp Flow Rate: High Flow Range: used in both 350-D and Liters/Minute ± 10% Low Flow Rate: 350-D only used in laparoscopic and endoscopic procedures Liters/Minute ± 10% Activation: ESU Sensor, laser footswitch sensor, and manual switch The AORN recommended practices for electrosurgery states, Exposure to smoke plume generated during electrosurgery should be reduced. This plume contains chemical by-products, and research suggests that there is little difference between laser and electrosurgical plume. Any smoke plume or noxious fumes are irritating to the respiratory tract. The potential for bacterial and viral contamination from surgical smoke is undefined; however it is known that mutagenicity of the gaseous by-products do exist. A wall suction device with an in-line filter is sufficient in keeping the air clear of smoke, a single - or triple-filter smoke evacuation unit should be used according to the need demonstrated. Regardless of the type of evacuation system used, the capture device should be placed as close as possible to the source of plume generation. -- AORN Journal, Vol. 68, No. 5. Clinical Issues: Smoke Plume, November,
15 Make the Right Connection SMOKE EVACUATION SYSTEMS & PRODUCTS ExtendEVAC Smoke Evacuation Pencils and Attachments Integral to pencil for use with wall suction or any smoke evacuation machine Clear visible tip allows visualization of entire electrode tip Revolutionary low profile ExtendEVAC pencil with integral telescoping smoke evacuation tip Adjusts electrode from 1 to 6 without changing electrode, saving time and money Telescoping smoke evacuation remains close to cautery site for optimum performance Soft tubing with swivel for ease of use ENT version available with clear narrow telescoping tip for tight spaces Product No. Product No. Uncoated Coated Description Quantity ExtendEVAC Button Switch Pencil w/telescoping Smoke Evacuator Tip,10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs ExtendEVAC w/15 Cord, 10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-00M M722 ExtendEVAC w/ent Electrode Assembly, 10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs ExtendEVAC PTFE Blade, 10 Tubing C\, Diameter, Holster 1/Pk, 10 Pks/Bx, 1 Bx/Cs ExtendEVAC w/microneedle, 10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-00M M3C Replacement Telescoping ENT Blade Electrode Assembly for ExtendEVAC 1/Pk, 25 Pks/Bx, 1 Bx/Cs ExtendEVAC w/1 Needle, 10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs C 1 Blade for ExtendEVAC Pencil 1/Pk, 25 Pks/Bx, 1 Bx/Cs C 1 Needle for ExtendEVAC Pencil 1/Pk, 25 Pks/Bx, 1 Bx/Cs 88-00M M726 ExtendEVAC w/removable ENT Electrode, 10 Tubing, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs ExtendEVAC w/45º Blade, 10 Tubing, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs All smoke evacuation products are available bulk Non-Sterile by adding NS to the end of any product number. 15
16 Electrosurgical & Smoke Evac Products SMOKE EVACUATION SYSTEMS & PRODUCTS Smoke Evacuation Machine Filters and Adapters Everything needed for use with both Crystal Vision machines and a variety of other smoke evacuation units High quality, dependable Competitively priced Non-sterile FILTERS Product No. Uncoated Description Quantity ULPA Water Trap Filter with C\, Tubing Adapter for Crystal Vision Smoke Evacuation Units 1/Pkg, 10 Pkgs/Cs Charcoal Output Filter for Crystal Vision Smoke Evacuation Units 1/Cs Replacement ESU Sensor w/cable for Crystal Vision Smoke Evacuation Units 1/Cs Laser Foot Pedal Sensor w/cable 1/Cs ULPA Filter w/2 Tubing for Wall Suction Evacuation of Smoke 1/Pkg, 10 Pkgs/Cs Footswitch 1/Cs 16
17 Make the Right Connection SMOKE EVACUATION SYSTEMS & PRODUCTS ADAPTERS Product No. Uncoated Description Quantity Suction Canister Adapter 30Fr Z\v to C\, 10/Cs Tubing Adaptor C\, for Crystal Vision Smoke Evacuation ULPA Water Trap filter 10/Cs High Flow Smoke Evacuation Filter for Crystal Vision units 10/Cs Filter Adaptor C\, to M\, for Smoke Evacuation Units from Buffalo Filter, Stackhouse, Class, Sorenson Labs, Nordex Medical, Conmed, and Neptune from Stryker 10/Cs Prefilter Adapter for ValleyLab OptiMumm & Air Force Smoke Evacuation units 10/Cs In-Line T Connector* 10/Cs * To split suction line from regulator between roll stand and smoke evacuation. All smoke evacuation products are available bulk Non-Sterile by adding NS to the end of any product number. 17
18 Electrosurgical & Smoke Evac Products SMOKE EVACUATION SYSTEMS & PRODUCTS Universal Smoke Evacuation Attachments and Accessories Universal snap-on sheath attachments convert standard pencil into a smoke evacuation pencil Fits all electrosurgical pencils available on market Also available pre-attached to DeRoyal Cautery Pencil Product No. Product No. Uncoated Coated Description Quantity Universal Smoke Evacuation Attachment w/10 Tubing C\, Diameter 1/Pk, 25 Pks/Bx, 1 Bx/Cs Rocker Switch Pencil w/smoke Evacuation Attachment, 10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs Button Switch Pencil w/smoke Evacuation Attachment, 10 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs Universal Smoke Evacuation Attachment w/1 Tubing C\, Diameter 1/Pk, 25 Pks/Bx, 1 Bx/Cs Rocker Switch Pencil w/smoke Evacuation Attachment, 1 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs Button Switch Pencil w/smoke Evacuation Attachment, 1 Tubing C\, Diameter, Holster 1/Pk, 25 Pks/Bx, 1 Bx/Cs Extension Tip for Smoke Evac Attachment 1/Pk, 25 Pks/Bx, 1 Bx/Cs All smoke evacuation products are available bulk Non-Sterile by removing initial zeros after the dash and adding NS to the end of any product number (Ex: NS). With the current recommendations for our health and safety, the DeRoyal smoke evacuator provides smoke evacuation as close to the surgical site as possible. This, coupled with its ease of use for staff and the minimally disruptive noise for surgeons, made it our hospital s choice. -- Teresa Cobleigh, RN, Unit Educator of Surgery, Antelope Valley Hospital, Antelope Valley, CA 18
19 Make the Right Connection SMOKE EVACUATION SYSTEMS & PRODUCTS Smoke Evacuation Tubing & Accessories for Laparoscopic or Laser Procedures Laparoscopic tubing used in conjunction with Crystal Vision Machine for automatic smoke removal without loss of pneumoperitoneum Hand-held wand ideal for evacuating smoke during laser procedures Speculum smoke evac tubing fits on speculum port for hands-free smoke removal using wall suction or machine Product No. Description Smoke Evac Extension/Speculum Tubing C\, Diameter w/male Barb (Ideal for laser procedures) Laparoscopic Smoke Evac Trocar Tubing for Crystal Vision Smoke Evacuation Units Smoke Evacuation Wand, 10 Tubing, High Flow Filter* Smoke Evacuation Wand, 10 Tubing Micromanipulator Smoke Nozzle 400 mm, w/o Tubing *Must be used only with Crystal Vision Machine. Packaged Sterile 1/Pk, 25 Pks/Bx, 1 Bx/Cs unless otherwise noted. 19
20 Electrosurgical & Smoke Evac Products ILLEGAL RESTRAINTS OF TRADE DeRoyal electrosurgical products are compatible with any electrosurgical unit on the market, but to be certain and/or to answer any questions the customer might have regarding compatibility, that customer should inquire with the original manufacturer of the electrosurgical unit being used at the customer s facility. Upon any inquiry, the customer may find that some suppliers require purchase of only their accessories as a condition of initial purchase. These suppliers may also state that warranties and/or guarantees would be otherwise invalidated. Typically, according to the Supreme Court precedent and federal law, arrangements (in which the sale or support of one product is conditioned upon the purchase or utilization of a separate product from the same manufacturer/supplier) are often considered to be tying arrangements which may constitute an illegal restraint of trade. Clearly, the important considerations for the customer are the technical and economic comparisons between competing products and DeRoyal electrosurgical products, which are the finest available. DEROYAL CUSTOMER INDEMNIFICATION POLICY DeRoyal electrosurgical products carry with them the company s superior workmanship, materials and design, and the further assurance that reasonable care was utilized in the manufacture of these products. DeRoyal will replace, at no charge, any electrosurgical products which fail to meet DeRoyal s standards of workmanship, materials, or design, although DeRoyal will not be responsible for damage after delivery, due to accident, improper use or abuse; or failure to follow instructions provided by DeRoyal. Included in this replacement policy are electrosurgical generators, if damaged, and such damage proven to be solely caused by a defective DeRoyal electrosurgical product or the incompatibility of the DeRoyal product with the electrosurgical generator. Finally, DeRoyal will indemnify the medical facility for any loss or claims for burns proven to be caused by defective DeRoyal electrosurgical products, subject to the conditions that: 1) The medical facility and its associated personnel have, in all respects and at all times, adhered to the instructions provided by DeRoyal. 2) The medical facility has furnished prompt records of any and all claims of damage allegedly caused by defective DeRoyal electrosurgical products by certified mail to DeRoyal at 200 DeBusk Lane; Powell, TN ) The medical facility cooperates fully with DeRoyal to solve the problem, and in the investigation and defense of any claim. DISCLAIMER Information provided by DeRoyal to customers and potential customers, treatment and product suggestions, and billing code designations, is provided for the convenience of our customers and does not constitute medical device DeRoyal Reprint # Rev. 3/14 DeRoyal Industries, Inc. 200 DeBusk Lane Powell, TN USA or
SUCTION & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING
SUCTION INSTRUMENTS & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING A complete line of quality, disposable Suction Instruments and Tubing to meet your
The System 5000. Electrosurgical Unit (ESU)
The System 5000 Electrosurgical Unit (ESU) The standard in consistent energy delivery, the System 5000 unites proprietary dynamic response technology with an array of specialty modes for desired clinical
ConMed Electrosurgery
ConMed Electrosurgery 2013-2014 Product Catalog Altrus Thermal Tissue Fusion Bend-a-beam Malleable abc handpieces System 5000 Goldvac Electrosurgical Generator Smoke evacuation Pencil Ordering information:
Smith & Nephew DYONICS RF Radiofrequency System
I-1 Smith & Nephew DYONICS RF Radiofrequency System Smith & Nephew is proud to present a variety of RF options to meet the specialized needs of today s arthroscopist. The DYONICS RF Radiofrequency System
Gynecology TRUCLEAR. Hysteroscopes/ Cytourethroscopes, Hysteroscopic Sheaths and Laparoscopes. Hysteroscopic Morcellator
Gynecology TRUCLEAR Hysteroscopic Morcellator Safe and efficient technique for removal of endometrial polyps and submucous fibroids One-step morcellation and aspiration without using electrosurgery Continuous
Fire Risk Assessment Tool: Instructions for Use
Fire Risk Assessment Tool: Instructions for Use Purpose of the Fire Risk Assessment Tool: To assist the perioperative team in determining and communicating the potential fire risk for each individual patient.
HF Electrosurgery Unit AUTOCON II 80 UNITS 7-2 07/2014-E
HF Electrosurgery Unit AUTOCON II 80 UNITS 7-2 07/2014-E HF Electrosurgery Unit AUTOCON II 80 The AUTOCON II 80 is a compact and high-performance HF electrosurgical unit which features a very attractive
User s Guide. RapidVac. Smoke Evacuator System
User s Guide RapidVac Smoke Evacuator System Foreword This manual and the equipment it describes are for use only by qualified medical professionals trained in the particular technique and surgical procedure
MIN Set. Instruments for Minimally Invasive Neurosurgery. Aesculap Neurosurgery
MIN Set Instruments for Minimally Invasive Neurosurgery Aesculap Neurosurgery MIN Set Features Fine instrument tips Especially important when working in very narrow spaces and close to sensitive structures.
HAND INSTRUMENTS. HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes. THE HiQ+ SERIES
HAND INSTRUMENTS HiQ+ Monopolar Hand Instruments Needle Holders Suction and Irrigation Monopolar HF Electrodes THE HiQ+ SERIES CONTENTS FORM FOLLOWS FUNCTION FOLLOWS YOUR NEEDS HiQ+ Monopolar and Standard...4
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Our thanks to OK International for allowing us to reprint the following. Why do we need fume extraction? Today s Electronics workplace
GYN 46 5.0 01/2016-E HYSTEROMAT E.A.S.I. Endoscopic Automatic System for Irrigation
GYN 46 5.0 01/2016-E HYSTEROMAT E.A.S.I. Endoscopic Automatic System for Irrigation NEW Easy The HYSTEROMAT E.A.S.I. is an intelligent, pressure-controlled double roller pump that maintains a constant
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Surgical scissors and forceps Product List
Surgical scissors and forceps Product List Sr. No Items Picture of Product Product specification 1 Grasping forceps-- 5 MM Grasping forceps are used to remove stones and retrieve foreign objects under
Surgical Smoke: What Do We Know. By Donna S. Watson, RN, MSN, CNOR, ARNP-BC
Surgical Smoke: What Do We Know By Donna S. Watson, RN, MSN, CNOR, ARNP-BC Many facilities have signage indicating that the facility is smoke-free. When in fact, there remain many facilities that this
LASER SAFETY. The use of lasers in the medical field is increasing at a tremendous rate.
LASER SAFETY The use of lasers in the medical field is increasing at a tremendous rate. As laser treatment increases the potential for laser accidents also increases. LASER SAFETY The Joint Commission
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
The forceps are available in addition to the standard models (s. catalogue of electrosurgical accessories).
E l e c t r o s u r g e r y B i p o l a r P R E M I U M F o r c e p s B i p o l a r I r r i g a t i o n F o r c e p s The ERBE Forceps R ange with its Non-Stick Effec t. NEW Advantages of the Non-Stick
COVIDIEN: Your solution for cardiology monitoring supplies.
Cardiology Products COVIDIEN: Your solution for cardiology monitoring supplies. WHY COVIDIEN CARDIOLOGY MONITORING SUPPLIES? Covidien is a market leader in monitoring, diagnostic, defibrillation and neonatal
ELECTROSURGERY PRODUCTS CATALOGUE
ELECTROSURGERY PRODUCTS CATALOGUE REUSABLE ACCESSORIES FOR ELECTROSURGERY SINGLE-USE ACCESSORIES FOR ELECTROSURGERY ELECTROSURGERY PADS ISO 9001 (2008) COMM/DOCU CHIR/022/15/C This document may be altered
Visceral surgery with ultrasonic technology by Söring: quick and with minimal bleeding.
VISCERAL SURGERY Visceral surgery with ultrasonic technology by Söring: quick and with minimal bleeding. www.soering.com Söring ultrasonic scissors and hooks: for visceral surgery. Gentle operating with
Selection & Use of Surgical Needles
Selection & Use of Surgical Needles EThALLOy * INTELLIGENT GEOMETRy ADVANCED NEEDLE COATING The Selection & Use of Surgical Needles EThICON Products needles are manufactured in a wide range of types, shapes,
EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS
77 78 90 x 14 mm Petri Dish Made in polystyrene. Vented. Supplied in groups of 20 units, packaged in heat sealed bags. Code 200200 is ASEPTIC. Code 200209 is sterile by gamma radiation. Suitable for automatic
Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding.
Hemostasis Solutions Boston Scientific is committed to improving patient care in the management of gastrointestinal bleeding. Through innovation and continuous educational support, we offer a wide range
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
EndoWorld GYN 37-1-E/11-2011. TROPHYscope CAMPO Compact Hysteroscope
EndoWorld GYN 37-1-E/11-2011 TROPHYscope CAMPO Compact Hysteroscope TROPHYscope CAMPO Compact Hysteroscope Foreword The new TROPHYSCOPE, CAMPO Compact Hysteroscope, is specially designed for office hysteroscopy
20 GALLON WET DRY VACUUM
20 Gallon Wet & Dry Vacuum 110" Water Lift Vac Motor 24" Front Mount Squeegee Assembly 50' Cord Special Tip Pour Feature Warranty Contractor Tool Kit Includes: Wet p/u Tool, Dry p/u Tool, Crevice Tool,
Coloplast Product Guide Ostomy, Continence, Wound & Skin Care. Effective March 2010
Coloplast Guide Ostomy, Continence, Wound & Skin Care Effective March 2010 SpeediCath TM Intermittent Catheters The only ready-to-use hydrophilic catheter. Clinical research indicated that twice as many
VACUUM CLEANER INSTRUCTION MANUAL
VACUUM CLEANER INSTRUCTION MANUAL MODEL: SVC9702 PLEASE READ THIS MANUAL CAREFULLY BEFORE USING AND KEEP IT PROPERLY FOR FUTURE USE 1 Safety Cautions: WARNING: To reduce the risk of fire, electrical shock,
USER S GUIDE. User s Guide Aaron 2250
USER S GUIDE User s Guide Aaron 2250 i ii Bovie Medical Corporation This manual and the equipment it describes are for use only by qualified medical professionals trained in the particular technique and
OPERATING ROOM SAFETY. Off-Site Locations
OPERATING ROOM SAFETY Off-Site Locations 1 The objective of this training program is to identify hazards present in operating rooms and to list actions that can be taken to minimize these hazards. 3 4
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
Mobile Video Cystoscopy from KARL STORZ
URO 43 8.0 05/2016-E Mobile Video Cystoscopy from KARL STORZ Digital Image Technology at Your Side 2 Digital All-in-One Solution Mobile Video Cystoscopy from KARL STORZ The C-VIEW video cystoscope from
GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT
PURPOSE To protect the health and welfare of GEORGIA TECH employees in areas where there may be a risk of injury or exposure to hazardous substances or conditions employees who work in areas where physical
9.0 Components Description. 10.0 SENTIO MMG System Quick Setup. 10.1 Plugging in Control Unit. 10.2 Attaching Sensor Harness
9.0 Components Description The main components of the SENTIO MMG System consist of the SENTIO MMG Control Unit with preinstalled SENTIO MMG Software and the SENTIO MMG Sensor Harness. The SENTIO MMG Control
The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty
The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty Ziemer Group We develop and produce diagnostic and surgical products for the ophthalmic
Laparoscopic Instruments
HOW TO TEST & INSPECT Laparoscopic Instruments are used to perform minimally invasive surgical procedures. Advantages of Laparoscopic Surgery Smaller incision, resulting in shortened recovery time, reduced
The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO
The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
CURL. Have a Question? Call Us First!
r e e ye CURL TM Have a Question? Please do not return this product to the retailer. Call Us First! Our customer service and product experts are ready to answer ALL your questions. Please call our TOLL-FREE
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Quality Care is at Your Fingertips. Surgical Sponges & Towels
Quality Care is at Your Fingertips Surgical Sponges & Towels Surgical Sponges & Towels DEROYAL SURGICAL SPONGES & TOWELS At DeRoyal, we know that clinician product needs can be exacting and variable, from
Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice
Bulk Storage the OIL SAFE Way OIL SAFE Bulk Systems are the most feature rich and highest quality lubricant storage and dispensing systems available. Fully Modular and ships ASSEMBLED Three System Types
Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter
Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter IC 192 Rev C A measure of flexibility and strength. Table of Contents 1. Introduction 2. What is the Morpheus CT PICC? 3. What
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
NIH Clinical Center Patient Education Materials Giving a subcutaneous injection
NIH Clinical Center Patient Education Materials What is a subcutaenous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous injection into the fatty
AST Standards of Practice for Use of Electrosurgery
AST Standards of Practice for Use of Electrosurgery Introduction The following Standards of Practice were researched and written by the AST Education and Professional Standards Committee and have been
ronc itrad "~' Set Automatic entry into the left main-stem bronchus Ordering Information Bronchitrac "L" Set
Bronchitrac "L" Set ronc itrad "~' Set Automatic entry into the left main-stem bronchus The only suction catheter specifically designed for left-bronchus access in an easy-ta-use tray. Simply advance the
Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS
Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS Operation Manual Read Before Using LUMI-TENS-INS-LAB-RevA08 TABLE OF CONTENTS INTRODUCTION TO TENS INDICATIONS AND CONTRAINDICATIONS WARNINGS
Microsuction Cannulae. Zoellner Range Fine Ends and Bellucci Range Frazier Range Laryngeal and Oesophageal Tubes Sundry
Microsuction Cannulae Zoellner Range Fine Ends and Bellucci Range Frazier Range Laryngeal and Oesophageal Tubes Sundry 02. Contents Page Zoellner Range Fine Ends and Bellucci Range Frazier Range Laryngeal
User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:
User Manual Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included: 1: Display Console 1: Control Box 2: Encoder (Wires attached) (Not Shown) 1: 5v Power Supply
POSITION DESCRIPTION/PERFORMANCE STANDARDS
POSITION DESCRIPTION/PERFORMANCE STANDARDS POSITION: Surgical Technologist DEPARTMENT: Surgery Position Purpose The Surgical Technologist is responsible for assisting the surgeon and/or Registered Nurse
GLOBE NEWS. LASIK - What are my Choices? A COMPREHENSIVE SELECTION OF INSTRUMENTS FROM KATENA. Katzen Flap Unzipper FOR OPHTHALMIC PROFESSIONALS
GLOBE NEWS VOLUME 9 NUMBER 1 FOR OPHTHALMIC PROFESSIONALS LASIK - What are my Choices? A COMPREHENSIVE SELECTION OF INSTRUMENTS FROM KATENA The growth of LASIK surgery has dramatically increased during
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.
Technique Guide Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting. Table of Contents Introduction Reamer/ Irrigator/ Aspirator (RIA) 2 Indications 4 Surgical Technique Preparation
USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.
USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487
Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION
ENTERAL NUTRITION Freka Enteral Feeding Tube Product Range Fresenius Kabi Limited, Cestrian Court, Eastgate Way, Runcorn, Cheshire WA7 1NT tel: 01928 533533 fax: 01928 533520 email: [email protected]
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.
Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)
Product Description: Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition) The NU G System uses pyrolysis thermal decomposition to treat infectious wastes typically generated in hospitals.
SATAjet 5000 B. Spray Guns I Cup Systems I Breathing Protection I Air Filtration I Accessories. As versatile as you
SATAjet 5000 B Spray Guns I Cup Systems I Breathing Protection I Air Filtration I Accessories As versatile as you Supreme fl exibility The SATAjet 5000 B The premium spray gun SATAjet 5000 B sets new quality
PA 03 basic device TECHNICAL DATA. English
PA 03 basic device English TECHNICAL DATA Type PA 03 Voltage 120 V - 60 Hz Power output max. 1000 Watt continuous control Outer dimensions approx. 34,9 x 36,5 x 46,6 cm (L x W x H) 3 Dear Pro-Aqua Customer!
MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC
RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side
Delivers the BEST SPRAY FINISH available on the market today! MADE IN THE USA WITH GLOBAL COMPONENTS
& Delivers the BEST SPRAY FINISH available on the market today! MADE IN THE USA WITH GLOBAL COMPONENTS Graco Handheld Sprayers the Best Choice for Small TrueCoat II sprayers are the fastest and easiest
Reflective Safety Products. Home Automotive Commercial
Reflective Safety Products Home Automotive Commercial Driveway Markers 2673 2689 2707 2706 2708 2661 2662 2690 12" Foot Spike 36" 46" 2673 12 Mini-Marker 6-Pack 2689, 2707 36 Driveway Marker 2706, 2708
POLARIS OPTICAL TRACKING SYSTEMS
POLARIS OPTICAL TRACKING SYSTEMS FROM A WORLD LEADER IN NAVIGATION TECHNOLOGY The Polaris Spectra and Polaris Vicra optical tracking systems from NDI are based on over 30 years of advanced 3D measurement
System Accessories Pricing. Page 0 Effective 7/02
System Accessories Pricing Page 0 Effective 7/02 Firetrace Tubing 200005 Firetrace Detection Tubing (FDT) (Per Foot) (Available in continuous lengths up to 333 ft.) Accessories 400001 400004 400061 400060
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
User s Guide. Force FX TM. Electrosurgical Generator C
User s Guide Force FX TM Electrosurgical Generator C User s Guide Force FX TM Electrosurgical Generator C 1012638 Preface This manual and the equipment it describes are for use only by qualified medical
Educational Tool for Medical Laser Programs 1. Laser Safety
Educational Tool for Medical Laser Programs 1 Laser Safety Dangers and hazards associated with the use of surgical laser systems require appropriate safety precautions and policies. The success of any
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.
Technique Guide Screw Removal Set. Instruments for removing Synthes screws. Table of Contents Introduction Screw Removal Set 2 Surgical Technique Preoperative Planning and Preparation 6 Removal of Intact
User Guide FOR FACE AND BODY SONIC SKIN CLEANSING. Become a Clarisonic Preferred Customer. Four Speeds + Body Setting. Three-Year Warranty
FOR FACE AND BODY User Guide Four Speeds + Body Setting Three-Year Warranty Adjustable T-Timer Charging Cradle Body Brush Head SONIC SKIN CLEANSING Beautiful skin begins with cleaner skin. Cleaner skin
WARNING To reduce the risk of. READ ALL INSTRUCTIONS BEFORE USING. KEEP AWAY FROM WATER DANGER Any appliance is
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS
Newloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists
Newloc Acetal Plastic Push-to-Connect Fittings Fluid Transfer Specialists Newloc Acetal Extremely easy to install no tools necessary Certified by the National Sanitation Foundation (NSF-1 and NSF-1) Instant
National- Spencer Inc.
9-27-2010 National- Spencer Inc. 19.2V HEAVY DUTY GREASE GUN PRODUCT SPECIFICATION Charger Input Power 110 VAC Battery Output Power 19.2V Battery Capacity 1500 MAH Battery Pack Charge Time 1 Hour Maximum
ProART Robotic Drop-in Transducer
User Guide Type 8826 ProART Robotic Drop-in Transducer English BB2084-C February 2013 For Professional Users Only LEGAL MANUFACTURER BK MEDICAL Mileparken 34 2730 Herlev Denmark Tel.:+45 4452 8100/Fax:+45
Introduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?
Introduction to Use of UV Light For the Control of Air Handler Contamination By Chris Willette Since the energy crisis of the 70 s, we have been forced to build our homes tighter and tighter to save on
Helping to protect you from exposure to hazardous drugs
Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented
SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions
SBC90 Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides important
Simplicity through innovation
RENASYS Soft Port Simplicity through innovation The new RENASYS Soft Port from Smith & Nephew represents a revolutionary advancement in Negative Pressure Wound Therapy (NPWT). This innovative Soft Port
User s Guide. LigaSure Vessel Sealing Generator
User s Guide LigaSure Vessel Sealing Generator This manual and the equipment it describes are for use only by qualified medical professionals trained in the particular technique and surgical procedure
Instructions for Use
Pleural Effusion Shunt with External Pump Chamber Catalog No. 42-9005 Instructions for Use Denver Biomedical, Inc. Table of Contents Description 2 Indications 2 Contraindications 2 Warnings 4 Cautions
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
SAFETY SAFETY APPAREL 20,000 PSI
SAFETY APPAREL TurtleSkin Water Armor is designed for UHP safety. Protection up to 2800 bar or 40,000 psi One size fits all money-saving design Modular design allows you to buy only what you need Replacement
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing
Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing Since 1952, Technical Devices has been supplying the electronics industry with the highest quality production
Safety, Operation and Maintenance Manual with Parts List
Safety, Operation and Maintenance Manual with Parts List 20-Gallon Wet/Dry Vac Important Information and Safety Instructions PLEASE READ BEFORE USE! # 961130020 9/10-Rev 1 20-Gallon Wet/Dray Vac TABLE
T16. Achieve up to 20% lower cost of ownership with Tennant s quality construction and innovative technologies
Creating a cleaner, safer, healthier world. EQUIPMENT T16 BATTERY-POWERED RIDER SCRUBBER Achieve up to 20% lower cost of ownership with Tennant s quality construction and innovative technologies Clean
Instructions. UV UltraVac_IM_B.indd 1 28/09/2011 15:23
Instructions UV UltraVac_IM_B.indd 1 28/09/2011 15:23 UV UltraVac_IM_B.indd 2 28/09/2011 15:23 Our beds can become home to millions of unwanted guests The most common are dust mites. They thrive in the
GENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS DESCRIPTION: Illuminated Kick Plate APPLICATION: Rogue (2011) PART NUMBER: 999G6 GX010 KIT CONTENTS: Item A B C G H QTY 1 1 1 D 1 E 1 F 3 15 6 Description Kick Plate,
PERSONAL PROTECTIVE EQUIPMENT FOR CALIFORNIA STATE UNIVERSITY, LOS ANGELES
PERSONAL PROTECTIVE EQUIPMENT FOR CALIFORNIA STATE UNIVERSITY, LOS ANGELES OCTOBER 2007 PROGRAM APPROVAL AND AUTHORIZATION James M. Rosser, President Date TABLE OF CONTENTS TITLE Section PURPOSE...1.0
HYLA NST Cleaning System
Owner s Manual HYLA NST Cleaning System The HYLA NST Cleaning System aspirates and cleans the air through a waterbased filtration process. The system is intended for household use only. Applications: Usual
MODEL #12006. Introduction
THE ORIGINAL PECO POWER SPRAYER PECO OWNER S MANUAL MODEL #12006 (Q0080) Revised: 1/8/2014 PECO POWER SPRAYER MODEL #12006 TABLE OF CONTENTS SECTION PAGE SECTION PAGE INTRODUCTION - - - - - - - - - - -
WSD130 SOLDERING STATION
NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
Electric Egg Boiler. Instruction Manual. Model Number: AEB-917
Electric Egg Boiler Instruction Manual Model Number: AEB-917 Congratulations! Your Egg Boiler will surely become one of the most versatile and practical appliances in your home. Please read the following