1 EN technical manual _12
2
3 TABLE OF CONTENTS 1 GENERAL & TECHNICAL DATA Warnings and cautions Manual versions Technical specifications User s statement for Planmeca Intra EMC information SERVICE MODE Control panel How to enter/exit the service mode X-ray tube filament preheating voltage calibration kv range selection Operation of the preprogrammed settings keys (kv hold) Dimming the displays Duration of the displays dimming time-out Disabling the exposure key Automatic identification of the cascade card Specifying the PCB versions Ready-state setting RECALLING THE FACTORY PREPROGRAMMED EXPOSURE VALUES TROUBLESHOOTING ERROR MESSAGES Error message shortform table Detailed error message explanations MECHANICAL ADJUSTMENTS Adjusting the balance of the arm Adjusting the bracket arm angles Adjusting the stiffness of the tube head s horizontal axle Vertical tube head stiffness adjustment screw PARTS REPLACEMENT & REPAIR Replacing the Generator PCB Replacing the tube head PCB Replacing the tube head Replacing the arm cables Replacing the control panel cable DIAGRAMS COPYRIGHT PLANMECA PUBLICATION NUMBER revision 12 Technical manual Planmeca Intra x-ray unit TOC-1
4
5 GENERAL & TECHNICAL DATA 1 GENERAL & TECHNICAL DATA 1.1 Warnings and cautions WARNING THE FOLLOWING WARNINGS, CAUTIONS AND NOTES MUST ALWAYS BE CONSIDERED WHILE SERVICING THE UNIT, IN ORDER TO AVOID EITHER PERSONAL INJURY OR DAMAGE TO THE UNIT. CAUTION RADIATION SAFETY RULES Some procedures described in this manual produces X-ray radiation. Always follow the rules for radiation protection. Never attempt to open the tube head. It does not contain any serviceable parts, and radiation safety could not be guaranteed any more. CAUTION ELECTRICAL SAFETY RULES The unit contains hazardous voltages. While servicing internal parts, always turn off externally the power to the unit, and wait for 2 minutes before touching any electrical parts. Always replace the fuses with ones of the same type and rating. Otherwise patient, operator or equipment safety cannot be guaranteed. The circuit boards can be damaged due to static discharges and require careful handling. CAUTION GENERAL SAFETY RULES The unit must be serviced only by qualified personnel, trained by PLANMECA. Repairs and parts replaced by unqualified personnel carry no warranty. Periodical maintenance as described in this manual must be performed on a regular basis, to ensure the safety and image quality of the unit. Some procedures described in the unit could be dangerous, if not followed as stated. Technical manual Planmeca Intra x-ray unit 1
6 GENERAL & TECHNICAL DATA CAUTION Check that the X-ray unit is installed properly and no mechanical play caused by wear, corrosion, metal fatigue or ageing can be found between the wall bracket and horzontal arm. 1.2 Manual versions Planmeca pursues a policy of continual product development. Although every effort is made to produce up-to-date product documentation this publication should not be regarded as an infallible guide to current specifications. We reserve the right to make changes without prior notice. NOTE This manual is only valid for the software versions from 3.01 and later. 2 Planmeca Intra x-ray unit Technical manual
7 GENERAL & TECHNICAL DATA 1.3 Technical specifications Generator Constant potential, microprocessor controlled, operating frequency 66 khz X-ray tube Toshiba D-0711SB Focal spot size 0.7 mm according to IEC Cone diameter 60 mm (2.36 in.) Rectangular 33 x 43 mm (1.30 x 1.69 in.) Max. symmetrical radiation field ø 60 mm at SSD 200 mm ø 60 mm at SSD 300 mm according to IEC 806 Total filtration min. 2 mm Al equivalent at 70 kv according to IEC Inherent filtration 1 mm Al equivalent at 70 kv according to IEC Anode voltage 50, 52, 55, 57, 60, 63, 66, 70 kv, ±2 kv Anode current 8, 7, 6, 5, 4, 3, 2 ma ±(5% ma) Target angle 16 Exposure times sec. ±(5% sec.), 26 steps Reference current time product 8 mas at 70 kv, 8 ma, 1 sec. Lowest current time product 0.02 mas at 2 ma, 0.01 sec. Max. nominal anode voltage 70 kv Max. electrical output 560 W at 70 kv, 8 ma Electrical output at 0.1 sec. 560 W at 70 kv, 8 ma Max. loading energy 1800 mas/h at 70 kv SSD (Source-Skin Distance) Standard/Long Long with rectangular collimator 200 mm (8 in.)/300 mm (12 in.) 306 mm (12.04 in.) Mains voltage 100 V~/ V~/ V~ Apparent resistance 0.3 ohms V~ / 0.8 ohms V~ Mains frequency 50/60 Hz Fusing 8 AT 250 VAC at V~ 15 AT 250 VAC at 100 V~/ V~ Duty cycle 1:15, automatic control Electrical classification Class I Type B Technical manual Planmeca Intra x-ray unit 3
8 GENERAL & TECHNICAL DATA Mechanical data Weight total 23 kg (51 lbs) tube head 4.2 kg (9.3 lbs) with standard cone 4.5 kg (10 lbs) with long cone Color RAL 9016 Environmental requirements Ambient temperature operating +5 C C storage -10 C C Humidity 25% - 75% External mains fuse recommendation The recommendation for the external mains fuses are: units with 100V~ or 115V~ voltage setting: 16A, time lag units with V~ voltage setting: 10A, time lag No other equipment should be connected to the same fused mains line as the x-ray unit. In some countries an additional external fault current guard is also required. Original manufacturer PLANMECA Oy, Asentajankatu 6, FIN-00880, Helsinki, FINLAND phone: Planmeca Intra x-ray unit Technical manual
9 GENERAL & TECHNICAL DATA 1.4 User s statement for Planmeca Intra Radiation leakage technique factors The maximum rated peak tube potential is 70 kv and the maximum rated continuous tube current is 0.53 ma for the maximum rated peak tube potential. Minimum filtration The radiation port contains an added 1.0 mm aluminium filtration. The measured half-value is at 70 kv. The measured value corresponds to an aluminium equivalent of 2.0 mm. Rated line voltage 100, , V~ ±10%. Line voltage regulation 10%. Maximum line current 6.1 A at 230 V~, 12.2 A at 115 V~ Technique factors that constitute the maximum line current condition 70 kv, 8 ma Generator rating and duty cycle 1.4 kw, duty cycle 1:15. The wait period is controlled automatically by calculating it according to the formula tw = 15 x texp. Maximum deviation of peak tube potential from indicated value ± 2.0 kv Maximum deviation of tube current from indicated value ±10% Maximum deviation of exposure time from indicated value ±10% DEFINITION OF MEASUREMENT CRITERIA Exposure time The beginning and end points of the exposure time are defined at 70% of the peak radiation waveform measured with a calibrated x-ray monitor. Peak tube potential Is defined as the high voltage mean value measured with a calibrated non-invasive kvp meter. Tube current Is defined using the voltage over the feedback resistor measured with a calibrated multimeter. The ma value is calculated by dividing the voltage by the resistance value. Technical manual Planmeca Intra x-ray unit 5
10 GENERAL & TECHNICAL DATA The nominal x-ray voltage together with the highest x-ray tube current obtainable from the high-voltage generator when operated at it s highest x- ray tube voltage 70 kv, 8 ma The nominal x-ray tube current when operated at the highest x-ray tube voltage 8 ma, 70 kv The x-ray tube voltage and tube current which result in the highest electric output power 70 kv, 8 ma The nominal electric power for a load time of 0.1 sec and at the nominal x- ray tube voltage 1.4 kw at 70 kv, 8 ma Anode heating/cooling curve of the X-ray tube 6 Planmeca Intra x-ray unit Technical manual
11 GENERAL & TECHNICAL DATA X-ray tube assembly heating/cooling curve X-ray tube assembly heating/cooling curve W W Heat Storage (kj) Cooling Time (min) Technical manual Planmeca Intra x-ray unit 7
12 GENERAL & TECHNICAL DATA 1.5 EMC information WARNING Use of any accessories and cables other than those specified in Planmeca Intra X-ray unit s documentation, with exception of cables sold by Planmeca as replacement parts for internal components, may result in increased emission or decreased immunity of the X-ray unit. WARNING Planmeca Intra X-ray unit should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the Planmeca Intra X-ray unit should be observed to verify normal operation in configuration which it will be used. Guidance and manufacturer s declaration - electromagnetic emissions Planmeca Intra X-ray unit is intended for use in the electromagnetic environment specified below. The customer or the user of the Planmeca Intra X-ray unit should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC Voltage fluctuations/ flicker emissions Group 1 Class B Class A Complies Planmeca Intra X-ray unit uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. Planmeca Intra X-ray unit is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. IEC Planmeca Intra x-ray unit Technical manual
13 GENERAL & TECHNICAL DATA Guidance and manufacturer s declaration - electromagnetic immunity Planmeca Intra X-ray unit is intended for use in the electromagnetic environment specified below. The customer or the user of Planmeca Intra X-ray unit should assure that it is used in such an environment. Immunity test IEC test level Compliance level Electromagnetic environmentguidance Electrostatic discharge (ESD) IEC ±6 kv contact ±8 kv air ±6 kv contact ±8 kv air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Electrical fast transient/burst IEC ±2 kv for power supply lines ±1 kv for input/output lines ±2 kv for power supply lines ±1 kv for input/output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC ±1 kv line to line ±2 kv line to earth ±1 kv line to line ±2 kv line to earth Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC <5 % U T (>95 % dip in U T ) for 0,5 cycle 40 % U T (60 % dip in U T ) for 5 cycles 70 % U T (30 % dip in U T ) for 25 cycles <5 % U T (>95 % dip in U T ) for 0,5 cycle 40 % U T (60 % dip in U T ) for 5 cycles 70 % U T (30 % dip in U T ) for 25 cycles Mains power quality should be that of a typical commercial or hospital environment. If the user of Planmeca Intra X-ray unit requires continued operation during power mains interruptions, it is recommended that Planmeca Intra X-ray unit be powered from an uninterruptible power supply. Power frequency( 50/60 Hz) magnetic field IEC <5 % U T (>95 % dip in U T ) for 5 s 3 A/m 3 A/m <5 % U T (>95 % dip in U T ) for 5 s NOTE U T is the a.c. mains voltage prior to application of the test level. Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. The power frequency magnetic field should be measured in the intended installation location to assure that it is sufficiently low. Technical manual Planmeca Intra x-ray unit 9
14 GENERAL & TECHNICAL DATA Guidance and manufacturer s declaration - electromagnetic immunity Planmeca Intra X-ray unit is intended for use in the electromagnetic environment specified below. The customer or the user of Planmeca Intra X-ray unit should assure that it is used in such an environment. Immunity test IEC test level Compliance level Electromagnetic environmentguidance Portable and mobile RF communications equipment should be used no closer to any part of the Planmeca Intra X-ray unit, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance Conducted RF IEC Vrms 150 khz to 80 MHz 3 Vrms d = 1.2 P d = 1.2 P 80 MHz to 800 MHz Radiated RF IEC V/m 80 MHz to 2.5 GHz 3 V/m d = 2.3 P 800 MHz to 2.5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a b Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which Planmeca Intra X-ray unit is used exceeds the applicable RF compliance level above, Planmeca Intra X-ray unit should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating Planmeca Intra X-ray unit. Over the frequency range 150 khz to 80 MHz, field strengths should be less than 3 V/m. 10 Planmeca Intra x-ray unit Technical manual
15 GENERAL & TECHNICAL DATA Recommended separation distances between portable and mobile RF communications equipment and Planmeca Intra X-ray unit Planmeca Intra X-ray unit is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of Planmeca Intra X-ray unit can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Planmeca Intra X-ray unit as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 khz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz d = 1.2 P d = 1.2 P d = 2.3 P Technical manual Planmeca Intra x-ray unit 11
16 SERVICE MODE 2 SERVICE MODE 2.1 Control panel Preprogrammed setting keys and indicator lights Exposure warning indicator light Adult/child selection key and indicator light Ready indicator light Exposure key kv display 66 8 ma display Time display Mode key Select key Parameter adjustment keys 2.2 How to enter/exit the service mode Press and hold down the select key for 4 seconds. Press and hold down the Mode key for more than 2 seconds, until the four uppermost preprogrammed setting indicator lights come on. To exit from the service mode Press the Mode key briefly. 12 Planmeca Intra x-ray unit Technical manual
17 SERVICE MODE 2.3 X-ray tube filament preheating voltage calibration Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press and hold down the adult/child mode selection key for 2 seconds or until the indicator light starts to blink. The indicator lights will start to blink indicating that you are in the preheating voltage calibration mode. Move as far away from the x-ray tube as the length of the cable from the control panel permits. Press and hold the exposure key on the control panel until 16 exposures are performed (approx. 30 seconds). Press the Mode key briefly to exit the service mode. 2.4 kv range selection Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 14 appears on the kv display. 14 Parameter adjustment up -key 0 The code of the kv range (0-9) is shown on the time display. The kv ranges are: 0 = 50-70, 1 = 55-70, 2 = 60-70, 3 = 66-70, 4 = 70, 5 = 50-68, 6 = 55-68, 7 = 60-68, 8 = and 9 = 68 kv. Press the Select key until the kv range code starts to blink, and the range can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new kv range by pressing the Select key. Press the Mode key briefly to exit the service mode. Technical manual Planmeca Intra x-ray unit 13
18 SERVICE MODE 2.5 Operation of the preprogrammed settings keys (kv hold) Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 15 appears on the kv display. 15 Parameter adjustment up -key 0 The number indicating the operation of preprogrammed settings keys (0 or 1) is shown on the time display. 0: Normal operation (factory setting). The preprogrammed settings keys operate as described in the Planmeca Intra user s manual. 1: kv hold. The selection of a preprogrammed setting does not affect the prior manually inserted kv value, but the exposure time is recalculated to achieve constant optical density on the film. In the case the kv value is now manually altered, the exposure time will also be changed automatically. If the exposure time is manually altered, the unit will return into manual mode. At any time, the preprogrammed setting for the kv value, ma value and exposure time for any tooth position is called by selecting the preprogrammed setting and pressing the child mode selection key twice. Press and hold down the Select key until the number starts to blink, and the number can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new setting by pressing the Select key. Press the Mode key briefly to exit the service mode. 14 Planmeca Intra x-ray unit Technical manual
19 SERVICE MODE 2.6 Dimming the displays Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 16 appears on the kv display. 16 Parameter adjustment up -key 0 The number indicating the brightness of the displays (from 1 to 5, factory default is 5) is shown on the time display. Press the Select key until the number starts to blink, and the value can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new setting by pressing the Select key. Press the Mode key briefly to exit the service mode. Technical manual Planmeca Intra x-ray unit 15
20 SERVICE MODE 2.7 Duration of the displays dimming time-out Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 17 appears on the kv display. 17 Parameter adjustment up -key 0 The number indicating the time-out value (0, 1, 2, 3, 4, 5) is shown on the time display. The time-out values are: 0 = no dimming, 1 = 1 min., 2 = 2 min., 3 = 5 min., 4 = 20 min. and 5 = 60 min. Factory default is 1. Press the Select key until the number starts to blink, and the value can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new setting by pressing the Select key. Press the Mode key briefly to exit the service mode. 16 Planmeca Intra x-ray unit Technical manual
21 SERVICE MODE 2.8 Disabling the exposure key Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 18 appears on the kv display. 18 Parameter adjustment up -key 0 The number indicating the mode of exposure key operation is shown on the time display. 0 = exposure key normal operation, 1 = exposure key operation disabled. The factory default is 0. Press the Select key until the number starts to blink, and the value can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new setting by pressing the Select key. Press the Mode key briefly to exit the service mode. Technical manual Planmeca Intra x-ray unit 17
22 SERVICE MODE 2.9 Automatic identification of the cascade card Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 19 appears on the kv display. 19 Parameter adjustment up -key 108 The value indicating the type of the cascade card is shown on the time display. Value < 108 equals an old card and value 108 equals a new card. The type of the cascade card affects the adjustment functionality of the preheat and ma Specifying the PCB versions Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 20 appears on the kv display. 20 Parameter adjustment up -key 3 The value indicating the type of the PCB versions is shown on the time display. 1 = CPU PCB version C3 (or older) with older cascade PCB, 2 = CPU PCB version C5 with newer cascade PCB and 3 = CPU PCB version E1, works with both old and new cascade PCB. The factory default is 3. Press the Select key until the number starts to blink, and the value can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new setting by pressing the Select key. Press the Mode key briefly to exit the service mode. 18 Planmeca Intra x-ray unit Technical manual
23 SERVICE MODE 2.11 Ready-state setting The Planmeca Intra X-ray unit can be set so that the Ready indicator light will only come on when the Dimaxis program is ready for the exposure, i.e. the Waiting for exposure message is on the computer screen. Enter the service mode according to the instruction given in section 2.2 How to enter/exit the service mode on page 12. Press the parameter adjustment up key until the parameter number 21 appears on the kv display. 21 Parameter adjustment up -key 0 The number indicating the ready-state setting (0 or 1) is shown on the time display. 0: Normal operation (factory setting). The Planmeca Intra X-ray unit will go into Ready-state regardless of PC operation. 1: The Ready indicator light will only come on when the Dimaxis program is ready for the exposure Press and hold down the Select key until the number starts to blink, and the number can now be changed with the parameter adjustment keys. Select key Parameter adjustment keys Accept the new setting by pressing the Select key. Press the Mode key briefly to exit the service mode. Technical manual Planmeca Intra x-ray unit 19
24 RECALLING THE FACTORY PREPROGRAMMED EXPOSURE VALUES 3 RECALLING THE FACTORY PREPROGRAMMED EXPOSURE VALUES The factory preprogrammed exposure values are in the Planmeca Intra user s manual, section 9 EXPOSURE VALUES. Press and hold down any of the preprogrammed setting keys when switching the unit on. The error code E.29 will appear on the time display. E.29 Do not clear the error code by pressing the select key, but press the Occlusal exposure key for 6 seconds. The factory preprogrammed values and density value 0 will be stored into memory. Press this key 20 Planmeca Intra x-ray unit Technical manual
25 TROUBLESHOOTING 4 TROUBLESHOOTING 61 C The control panel displays do not come on and the indicator light of generator box is not on Problems in mains voltage, or a fuse is blown. Check the mains voltage. Check the mains cable. Check and replace, if necessary, the fuses located on the lower left side of the generator box. Open the generator box and check and replace, if necessary, the generator fuse F2. Replace the generator. (Perform the checks and parts replacements in this order). The control panel displays do not come on and the indicator light of generator box is on Control panel power failure, or the control panel is defective. The control panel operates with 12 V produced on the generator low voltage supply. Check the control panel cable and the telephone cable. Replace the control panel. (Perform the checks and parts replacements in this order). Temperature of the tube head too high If the temperature of the tube head exceeds 60 C, the temperature will appear on the time display. The control panel does not operate. Wait until the temperature drops. Technical manual Planmeca Intra x-ray unit 21
26 ERROR MESSAGES 5 ERROR MESSAGES E.11 The error code is displayed on the time display. Press the select key to clear the error from the display. 5.1 Error message shortform table ERROR CODE ERROR MESSAGE EXPLANATION E.00 Exposure key was released too early during the exposure. E.10 X-ray tube Anode voltage (kv) overshoot. E.11 X-ray tube Anode voltage (kv) dropped suddenly. E.12 X-ray tube cathode filament preheating voltages are not calibrated. E.13 Filament preheating voltage calibration failed. E.29 Membrane keyboard key short-circuited/pressed during the self test or faulty display board. E.30 kv value does not reach or it exceeds the given value (difference more than 5%). E.31 X-ray tube Anode current (ma) missing, or not in specified limits. E.33 X-ray tube Filament voltage (V) missing, or outside the range (too low or too high). E.34 X-ray tube Anode voltage (kv) missing, or below the specified limit. E.36 Too long exposure. E.37 kv feedback signal open circuit or short circuit. E.38 ma feedback signal open circuit or short circuit. E.50 Tube head temperature sensor short circuit. E.51 Tube head temperature sensor open circuit. E.52 Filament voltage feedback not in specified limits E.57 Exposure key pressed during self test. E.60 ± 15VDC voltage is out of limits E.61 Communication error between control panel and tube head CPU. 22 Planmeca Intra x-ray unit Technical manual
27 ERROR MESSAGES ERROR CODE ERROR MESSAGE EXPLANATION E.71 FLASH memory check-sum error (tube head CPU). E.81 EEPROM memory defective (tube head CPU). E.83 Config register error (tube head CPU). 5.2 Detailed error message explanations E.00 Exposure key was released too early during exposure The most probable cause (if the key really was pressed firmly during the whole exposure) is faulty control panel or faulty separate exposure switch. Replace the control panel or the separate exposure switch. Check the control panel cable, telephone cable and the arm cable. E.10 X-ray tube anode voltage (kv) overshoot This condition is monitored by the watch-dog circuit on the tube head PCB during the whole exposure and if the anode voltage rises above 95 kv the exposure is immediately aborted and this error indicated. A knocking sound may be heard from the tube head at the same time. This kind of arcing can occur now and then without any special reason, and should be considered a normal phenomenon. If however the occurrence frequency becomes too high, it could be an indication of a degrading tube head. If this error occurs constantly it is probably caused by a faulty tube head or tube head PCB or generator PCB (replace in this order). The possible reason is also faulty feedback cable (9 pole) in the tube head. E.11 X-ray tube anode voltage (kv) dropped suddenly The x-ray tube voltage suddenly drops, and a knocking sound is heard from the tube head at the same time. The exposure is aborted and this error indicated. This phenomenon should be considered quite normal if it doesn t occur frequently. If the generator is damaged during the exposure, or the arm/extension cable is broken, this error is indicated and during next exposure the error E.30 occurs. If this error occurs constantly it is probably caused by a faulty tube head or tube head PCB or generator PCB (replace in this order). The possible reason is also faulty feedback cable in the tube head. E.12 X-ray tube cathode filament preheating voltages are not calibrated The tube head PCB has been replaced, but the X-ray tube cathode filament preheating voltages are not calibrated. See paragraph 2.3 X-ray tube filament preheating voltage calibration on page 13 for details how to perform the calibration. Technical manual Planmeca Intra x-ray unit 23
28 ERROR MESSAGES E.13 Filament preheating voltage calibration failed During preheat calibration the filament voltage is measured to be in specified limits. The filament circuit in the tube head or in the tube head PCB is faulty or the tube head is faulty. Perform the calibration procedure again. If it fails, replace the tube head or tube head PCB (in this order). The possible reason is also faulty feedback cable in the tube head. E.29 Control panel key short-circuited/pressed during the self test This error can occur only during the self-test. During the self test the unit checks that all keys are open (normal state if not pressed). If a key is found to be in short circuit, this error is displayed. Because the control panel keys are arranged in a matrix, one key s short could cause the whole keyboard to operate erroneously, therefore this check is important. Replace the control panel. The factory predetermined settings are recalled and the density value is set to zero by pressing any of the keys during the self test. The error code E.29 appears on the time display, after which the right-hand preprogrammed setting key must be pressed and held down for 6 seconds. See section 3 RECALLING THE FACTORY PREPROGRAMMED EXPOSURE VAL- UES on page 20. E.30 kv value does not reach or it exceeds the given value (difference more than 5%) The tube voltage is sampled periodically (by the tube head CPU) and if the actual measured kv-value differs more than ± 3 kv from the specified value this error is displayed. The tube head, tube head PCB, generator PCB or arm/extension cable signals HV1, HV2 or KVC (see wiring diagram) can be faulty. See also error E.11 and E.34. Check the incoming mains voltage during the exposure. Check the arm/extension cable and the tube head feedback cable. Replace the generator PCB, tube head PCB or tube head (replace in this order). E.31 X-ray tube anode current (ma) missing, or not in specified limits The tube current is sampled periodically (by the tube head CPU) and if the actual measured ma-value differs more that ± 2 ma from the specified value this error is displayed. The tube head, tube head PCB or tube head feedback cable can be faulty. Proceed with the filament definition, see paragraph 2.3 X-ray tube filament preheating voltage calibration on page 13 for details. If this does not help and the error occurs constantly check the tube head feedback cable, replace the tube head PCB, or tube head (in this order). E.33 X-ray tube filament voltage (V) missing, or outside the range (too low or too high) The tube filament voltage is sampled periodically (by the tube head CPU) and if the actual measured filament voltage is not in the specified limits ( V) then this error is displayed. The filament circuit in the tube head or on the tube head PCB can be faulty. Check the tube head feedback cable. Replace the tube head PCB or the tube head (in this order). 24 Planmeca Intra x-ray unit Technical manual
29 ERROR MESSAGES E.34 X-ray tube anode voltage (kv) missing, or below the specified limit This error occurs in the beginning of the exposure, when the tube anode voltage does not rise. The tube head, tube head PCB, generator PCB or arm/extension cable signals HV1, HV2 or KVC (see wiring diagram) can be faulty. See also error E.11 and E.30. Check the incoming mains voltage during the exposure. Check the arm/extension cable and the tube head feedback cable. Replace the generator PCB, tube head PCB or tube head (replace in this order). E.36 Too long exposure The control panel CPU monitors the exposure time by measuring the state of the exp-signal. If, however, the tube head CPU continues the exposure more than the maximum exposure time, then the control panel CPU terminates the exposure and this error occurs. This is a safety procedure, that guarantees that the exposure is terminated under all conditions. Replace the tube head PCB if this error occurs repeatedly. E.37 kv feedback signal open circuit or short circuit The kv feedback signal is monitored by the tube head CPU. The internal connection of the tube head or tube head feedback cable is faulty. Check the condition of the feedback cable, replace the tube head PCB or the tube head (in this order). E.38 ma feedback signal open circuit or short circuit The ma feedback signal is monitored by the tube head CPU. The internal connection of the tube head or tube head feedback cable is faulty. Check the condition of the feedback cable, replace the tube head PCB or the tube head (in this order). E.50 Tube head temperature sensor short circuit The tube head temperature sensor signal is measured by the tube head CPU. The sensor is short-circuited, the tube head PCB or the tube head feedback cable is faulty. Check the feedback cable. Replace the temperature sensor (beside the signal connectors of the tube head), or the tube head PCB (in this order). E.51 Tube head temperature sensor open circuit The tube head temperature sensor signal is measured by the tube head CPU. The temperature sensor is damaged, the tube head PCB or the tube head feedback cable is faulty. Check the feedback cable. Replace the tube head PCB. E.52 Filament voltage feedback not in specified limits The filament voltage is monitored by the tube head CPU. The amplifier is faulty. Replace the tube head PCB. Technical manual Planmeca Intra x-ray unit 25
30 ERROR MESSAGES E.57 Exposure key pressed/failure during self test The tube head CPU checks the state of the exp-signal when the unit is switched on. The exposure key or the separate exposure switch can be short-circuited. The arm, extension, control panel or telephone cable can be faulty. The tube head PCB or the generator PCB can be faulty. Check the cables and the separate exposure switch. Replace the control panel, tube head PCB or the generator PCB (in this order). E.60 ± 15VDC voltage is out of limits The tube head CPU measures the internal voltages generated by tube head PCB power supply from the 12V operating voltage. If this error occurs before exposure, the tube head PCB is faulty. If the error occurs after the exposure, the generator 12V power supply is faulty, or the mains filtering capacitors charging circuit is faulty. The extension cable can be too long and/or the wire cross sections too small. If the error occurs immediately after switching the unit on, replace the tube head PCB. If the error occurs only after starting the exposure, measure the 12 V voltage at the generator PCB P13 connector. If the voltage drops at the beginning of the exposure (generator s green indicator light dims), replace the generator PCB. Check the connectors of the arm cable and the length of the extension cable, as well as the wire cross sections. The properties of extension cable are given in the figure below. Generator PCB Extension cable max.12 m Extension cable Connectors Arm cable (Std.) Grn Yel / Grn P1 P8 Molex Molex N.C. 6 Yel Wht Gry Blk Red Brn Blu Pink HV1 HV2 +12V EXP KVC GND SCL ELMP HV1 HV2 +12V EXP AUX1 AUX2 KVC GND SCL ELMP P6 P9 P7 P8 Molex-3 Molex-6 P14 Screw terminal +12V Gry 1 GND Brn 2 ELMP Pink 3 Ferrite E.61 Communication error between control panel and tube head CPU The tube head PCB s 12V voltage feed or the communication between the control panel and tube head CPU is failed. The arm/extension cable or control panel/telephone cable is faulty. Check the cables. Measure the 12V voltage at the tube head PCB P2 connectors pins 1 and 4. Check if the red LED D7 on the tube head PCB is on. Replace the tube head PCB, control panel or the generator PCB (in this order). 26 Planmeca Intra x-ray unit Technical manual
31 ERROR MESSAGES E.71 FLASH memory check-sum error (tube head CPU) Tube head CPU internal error. Replace the tube head PCB. E.81 EEPROM memory defective (tube head CPU) Tube head CPU internal error. Replace the tube head PCB. E.83 Config register error (tube head CPU) Tube head CPU internal error. Replace the tube head PCB. Technical manual Planmeca Intra x-ray unit 27
32 MECHANICAL ADJUSTMENTS 6 MECHANICAL ADJUSTMENTS 6.1 Adjusting the balance of the arm Adjust the balance of the arm by turning the adjustment nuts with a screwdriver. The adjustment nuts are located inside the bracket arm and can be reached through the openings at the under-side of the bracket arm. Openings for adjustments Arm in adjustment position NOTE Adjust the arm from the lower part of the adjustment nut. CORRECT WRONG Figure 1 28 Planmeca Intra x-ray unit Technical manual
33 kv MODE READY PRET ma SELECT BW s MECHANICAL ADJUSTMENTS 6.2 Adjusting the bracket arm angles In case the bracket arm angles need to be adjusted it can be done with the limiting plates. Remove the cover plug from the end of the bracket arm. Attach the limiting plate to the arm with two M3 Allen screws. Adjust the angle with the limiting plate adjustment screws. I_tech_2.eps Intradj1.eps Limiting plate Limiting plate adjustment screw Figure 2 Technical manual Planmeca Intra x-ray unit 29
34 MECHANICAL ADJUSTMENTS 6.3 Adjusting the stiffness of the tube head s horizontal axle Remove the plug from the tube head s axle and adjust the tightness of the two adjusting screws evenly (arrows on the figure below). Adj_stiffness.eps WARNING! Do not touch the painted screws or the earth spring attachment screw. ø 2.5 Allen screw Figure 3 30 Planmeca Intra x-ray unit Technical manual
35 MECHANICAL ADJUSTMENTS 6.4 Vertical tube head stiffness adjustment screw Adjust the stiffness of the vertical tube head by turning the adjustment screw on the support axle manually or with a wrench tool. The stiffness of the vertical tube head has been preadjusted at the factory, and can be changed, if necessary. Turn the adjustment screw 0,5-1 rounds clockwise if you want to tighten the tube head and 0,5-1 rounds counterclockwise to loosen it. NOTE Do not turn the adjustment screw too much counterclockwise to avoid the screw to come loose. intra_stiffness.eps Vertical tube head stiffness adjustment screw Figure 4 Technical manual Planmeca Intra x-ray unit 31
36 Complies with DHHS radiation performance standards 21 CFR Subchapter J. 220V V 8 AT 100V V 15 AT WARNING: For continued protection against risk of fire replace only with same type and rating of fuse. 70kV maximum 1800 mas/h Total filtration: 2,0 mm EquAl 1000VA 50/60Hz Manufactured by: Planmeca OY HELSINKI FINLAND LBL-Z-006D 0537 PARTS REPLACEMENT & REPAIR 7 PARTS REPLACEMENT & REPAIR WARNING Make sure that the power supply is switched off before starting parts replacement. 7.1 Replacing the Generator PCB a) Unscrew the three M4x6 ULS screws and remove the generator cover. Generator cover I_7A.eps Figure 5 32 Planmeca Intra x-ray unit Technical manual
37 PARTS REPLACEMENT & REPAIR b) Measure that the mains voltage is not present at the mains input terminals (P5) marked N and L. c) Disconnect the connectors from terminals P1, P3, P5, P6 P7, P8 and P9. P5 P3 P6 P1 P8 I_tech_3APSU2.eps P7 P9 Figure 6 d) Loosen the four M4x8 ISO 7380 screws of the generator assembly frame (Fig. 7, 1). Lift the generator assembly upwards (Fig. 7, 2). The generator assembly can now be lifted away from the wall adapter (Fig. 7, 3). 1 I_tech_4_2APSU2.eps Figure 7 Technical manual Planmeca Intra x-ray unit 33
38 PARTS REPLACEMENT & REPAIR e) Remove the eight M4 DIN 934 attachment nuts and ø4.3 DIN 6798 washers from the Generator PCB (Fig. 8, 1). Unscrew the two M4x8 DIN 84 screws (Fig. 8, 2). Lift the generator assembly away from the wall adapter and open the two M3x6 DIN 912 screws located behind the generator assembly frame (Fig. 8, 3). f) Remove the Generator PCB. 1 2 M4 DIN 934 nut and M4 washer I_tech_4_3APSU2.eps 3 1 Figure 8 g) Install the new Generator PCB in reverse order. Note, that the new Generator PCB is not attached to the frame with the two M3x6 DIN 912 screws located behind the generator assembly frame. 34 Planmeca Intra x-ray unit Technical manual
39 PARTS REPLACEMENT & REPAIR 7.2 Replacing the tube head PCB a) Unscrew the two M4x20 DIN 7984 fastening screws (Fig. 9, 1) of the cone (Fig. 9, 2) (inside the cone). b) Remove the tube head front cover (Fig. 9, 3) and the cone. c) Disconnect the two connectors from the tube head PCB (Fig. 9, 4). d) Pull the tube head PCB (Fig. 9, 5) from the tube head. e) Install the new PCB in reverse order. f) Perform the x-ray tube filament preheating voltage calibration, see section 2.3 X-ray tube filament preheating voltage calibration on page Figure 9 Technical manual Planmeca Intra x-ray unit 35
40 PARTS REPLACEMENT & REPAIR 7.3 Replacing the tube head a) Remove the tube head PCB as described in section 7.2 Replacing the tube head PCB on page 35. b) Unscrew the six fastening screws of the tube head cover (Fig. 10, 1) and remove the cover (Fig. 10, 2). c) Unscrew the five screws from the support frame (Fig. 10, 3) and remove the tube head (Fig. 10, 4). Note, that there is a grounding plate under the lower left attachment screw. d) Install the new tube head in reverse order. Make sure that the grounding plate touches the tube head PCB. NOTE Do not overtighten the tube head cover fastening screws to avoid damaging the cover. e) Perform the x-ray tube filament preheating voltage calibration, see section 2.3 X-ray tube filament preheating voltage calibration on page Grounding plate Figure Planmeca Intra x-ray unit Technical manual
41 PARTS REPLACEMENT & REPAIR 7.4 Replacing the arm cables NOTE NOTE The Dixi interconnection cable is attached to the arm cable and you have to replace both cables. The Dixi interconnection cable is attached to the new arm cable at the factory. The x-ray units with serial number IXRF41386 or smaller need old 7mm (0.28 in.) thick arm cable, part number Do not use the new, 9mm (0.35 in.) thick arm cable (part number ) in these x-ray units. a) Remove the tube head as described in section 7.3 Replacing the tube head on page 36. a) Unscrew the three M4x6 ULS screws and remove the generator cover. b) Disconnect the arm cable connectors from the Generator PCB (terminals P1 and P8). Detach the grounding lead of the arm cable. (Fig. 11, 1). c) Remove the extension arm cover plugs (Fig. 11, 2). d) Pull the arm cable and the Dixi interconnection cable through the extension arm. e) Detach the plug of the tube head support (Fig. 11, 3). f) Remove the cover plug from the bracket arm opening. Detach the Dixi interconnection cable from the Dixi control box OR pull the cable out from the bracket arm (Fig. 11, 4). g) Unscrew the M3x6 ISO 7380 screw of the tube head support (Fig. 11, 5) and remove the cover plate of the tube head support (Fig. 11, 6). The plate is attached with doublesided adhesive tape. h) Cut off the connectors from the tube head end of the arm cable push the cable through the support frame (Fig. 11, 7). Technical manual Planmeca Intra x-ray unit 37
42 PARTS REPLACEMENT & REPAIR i) Cut off the connectors from the generator end of the arm cable and Dixi interconnection cable. The grounding lead should be left longer that the other leads (Fig. 11, 8) Tech_1APSU2.eps Figure 11 j) Join the old and new cables together as shown in Fig. 12 below. Tape the joining point firmly. Do not tape the old Dixi interconnection cable, it is pulled out from the opening on the bracket arm (see figure Fig. 13) Old Dixi interconnection cable Grounding lead of the new cable Grounding lead of the old cable Tech_2A.eps Figure Planmeca Intra x-ray unit Technical manual
43 PARTS REPLACEMENT & REPAIR k) Coat the new arm cable with silicone, grease or similar. Pull from the tube head end of the arm cable and simultaneously move the arm up and down. Old Dixi interconnection cable Tech_3APSU2.eps New arm cable Figure 13 NOTE Make sure that the arm cable and the Dixi interconnection cable are not twisted when you are pulling them into the arm. l) Stop pulling when the new cable is mm out from the opening of the tube head support (Fig. 14, 1). Route the cable through the opening on the support frame (Fig. 14, 2) mm 2 Figure 14 Technical manual Planmeca Intra x-ray unit 39
44 PARTS REPLACEMENT & REPAIR m) Strip approx. 11 mm of the outer jacket of the cable. Slide the shield onto the interconnection cable. Align the leads and insert them into the RJ45 connector in the order shown on the Fig. 15 below. Colour according EIA/TIA-586A Green / White Green Orange / White Blue Blue / White Orange Brown / White Brown Green / White Green Orange / White Blue Blue / White Orange Brown / White Brown NOTE! The colours marked to the figure are only examples. The lead colours of the cable you are using can differ from the colours marked to the figure. Figure 15 Shield RJ45 connector Figure Planmeca Intra x-ray unit Technical manual
45 PARTS REPLACEMENT & REPAIR n) Insert the RJ45 connector into the cable crimp tool. Press the handles of the crimp tool as far as they will go. Check with the cable tester that the cable is functioning. Figure 17 o) Check the RJ45 connector to make sure that the cable is properly attached to the connector. RJ45 connector before crimp Wires UTP Cable RJ45 connector after crimp 11mm Wires UTP Cable Figure 18 Technical manual Planmeca Intra x-ray unit 41
46 PARTS REPLACEMENT & REPAIR p) Pull the Dixi interconnection cable out from the bracket arm opening. Connect the Dixi interconnection cable to the Dixi control box or push the cable into the bracket arm. Attach the cover plug to the bracket arm opening. Dixi interconnection cable Tech_4APSU2.eps Figure 19 q) Attach the tube head to the support frame with the five M4x8 DIN 7984 screws. r) Slide the tube head PCB into its position and connect the feedback cable to the tube head PCB terminal P1. s) Connect the arm cable leads to the connectors as described in Fig. 20 below. Red Black (thin) White Black Blue - Yellow - Yellow 1 1 Figure Planmeca Intra x-ray unit Technical manual
47 PARTS REPLACEMENT & REPAIR t) Connect the arm cable to the tube head PCB and connect the grounding lead to the grounding point near the support frame opening. Arm cable Grounding lead of arm cable Tube head grounding lead Feedback cable Figure 21 u) Check that the arm cable remains in the groove of the tube head support when moving the arm from one extreme position to another. Secure the arm cable to the support frame with a cable tie. v) Pull the cables through the extension arm and connect the cables to the generator assembly connectors. w) Replace the removed covers and plugs. Technical manual Planmeca Intra x-ray unit 43
48 PARTS REPLACEMENT & REPAIR 7.5 Replacing the control panel cable a) Press the clip of the connector (Fig. 22, 1) and pull the socket from the terminal of the generator box (Fig. 22, 2). b) Detach the connector from the control panel in the same way as from the generator box. c) Connect the new cable to the generator box and to the control panel. CAUTION Do not connect any other equipment to the terminal of the generator box Figure Planmeca Intra x-ray unit Technical manual
49 DIAGRAMS 8 DIAGRAMS Technical manual Planmeca Intra x-ray unit 45
50
51 Tube head assembly PLANMECA INIT SCL GND KVC EXP +12V Arm cable BLU BLK WHT BLK RED P2 F2 F1 +12V GND T+ MA+ MA- KV+ KV- To tube head P1 YELL YELL RED RED RED RED RED RED RED RED RED P3 P1 No serviceable parts Remote control Arm cable, Code Feedback cable, Code Tubehead grounding wire, Code Generator assembly PLANMECA P3 P1 Main switch cable, brown Code BLU BRN N Main switch cable, blue Code P5 TO MAINS P3 L SWITCH P6 VOLTAGE +12V SELECTOR BRN MAINS INPUT BLU PLANMECA P4 Mains voltage selector cable V~ Code TP5 Arm cable. conn. P14 Extensions cable ELMP GND +12V P8 Arm cavtble conn. BLU BRN FROM MAINS SWITCH P7 P9 P11 Dead man SW.conn GND TP6 P12 Mains voltage selector cable V~ Code Remote spiral keyboard conn. P13 +12V EXP GND SCL Remote keyboard conn. EXP RDY KV GRD P2 AUX.CONN. ON / OFF MainSwitch BLK +VCC RED EXP YEL ELMP GRN GND WHT SRL RED BLK WHT BLK BLU YELL YELL YELL/GRN YELL/GRN YELL YELL Planet Connector Code RED BLK WHT BLK BLU Power supply cable 115 V~ Code Power supply cable 220 V~ Code Display spiral cable Code Mains V~ ±10% V~ ±10% V~ ±10% PLANMECA O Y Asentajankatu 6, Helsinki Finland Tel Fax Date Prostyle intra X-ray unit Designed J.Kolehmainen Wiring diagram, standard wall mounting installation Drawn S.Jankavaara Approved J.Kolehmainen Rev.G
52
53
54 PLANMECA OY Asentajankatu 6, Helsinki, Finland tel , fax ,
Dual Chamber Temporary External Pacemaker
5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes
user's manual 10006187_19
EN user's manual 1000617_19 TABLE OF CONTENTS 1 INTRODUCTION...1 1.1 Symbols... 2 2 WARNINGS AND PRECAUTIONS...3 3 CHECKLIST - BEFORE USING THE UNIT...4 4 PLANMECA INTRA X-RAY UNIT - MAIN PARTS...5 4.1
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
EverFlo. EverFlo Q EN, DE DSF 4/16/08
1053621 EN, DE DSF 4/16/08 EverFlo EverFlo Q English Table of Contents Symbol Key... 2 Abbreviations... 2 Chapter 1: Introduction... 3 Intended Use... 3 About Your EverFlo / EverFlo Q...3 Parts of Your
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Drayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
W O R L D C L A S S H I F I
W O R L D C L A S S H I F I O W N E R S M A N U A L Accessories: NAPSC, i-supply, Headline, Stageline IMPORTANT In order to comply with current European safety regulations it is essential that the Naim
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit
Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure
Operating Instructions
Operating Instructions Vision 5L Digital Holter Recorder Document Number: 010-1646-00 Revision: H Bothell, Washington 98021-8969 (608)-764-1919 Caution: U.S. Federal law restricts this device to sale by
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
Heated HumidifieR 1031849 HM 1/6/06
Heated HumidifieR M Series USER Manual 1031849 HM 1/6/06 Table of Contents Introduction...3 In This Manual...3 Intended Use...3 Warnings and Cautions...3 Warnings...3 Cautions...4 Symbol Key...5 System
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions
LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions Description The LS-1 Series of tungsten halogen light sources are versatile, white-light lamps optimized for use in the
RADIANT PLASMA 4700 Plasma Spark Generator
RADIANT PLASMA 4700 Plasma Spark Generator Installation Guide / User Manual A S P A R K O F F R E S H A I R Aquapulser.com Contents 1 Introduction 2 1.1 About the Product....................................
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com. Installation and operating manual
Uni-Valve A /S VENTILER & INSTRUMENTER Telefon (+45) 43 43 82 00 Telefax (+45) 43 43 74 75 [email protected] www.uni-valve.com UNI-EL Electric actuator Installation and operating manual Remote position
Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004
Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Processor. Installation Guide
Processor Installation Guide Land Instruments International Dronfield, S18 1DJ England Telephone: (01246) 417691 Facsimile: (01246) 410585 Email: [email protected] Internet: www.landinst.com
PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT TECHNICAL MANUAL 788405/11 LAT LAT SIN DEX. kv kv. mas. mas CTL
LAT mas 8 3 2 1 LAT mas PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT OBL CC OBL SIN DEX kv kv TECHNICAL MANUAL En 788405/11 TABLE OF CONTENTS Chapter A Chapter B Chapter C GENERAL & TECHNICAL DATA 1 WARNINGS...............................................
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Broadband Telecommunications Drop Amplifier
INSTALL SHEET BDA Broadband Telecommunications Drop Amplifier Introduction The Broadband Telecommunications Drop Amplifier (BDA) is a two-way, 1 GHz amplifier designed for customer-premise amplification
ADACSNET USB Control Module
ADACSNET USB Control Module Installation Guide Termination Switch 2-Pin SensorNet Connection Features and Hookup The USB Control Module contains the following: - USB port: Connects to the host computer.
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
HCR3.2/.. Chipcard reader HOTEL SOLUTION
s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages
1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions
Compact presence detector Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe the instructions may cause
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Battery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.1 Important Safety Instructions Please save these instructions.
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
AR-721U/721K/661U User s Guide
AR-72U/72K/66U User s Guide Feb. 6, 2004 Table of Contents Page. Main Feature --------------------------------- 3 2. AR-72U Installation --------------------------------- 4 2. Steps ---------------------------------
OWNER S MANUAL. Permolock C3. Docking system for Power wheelchair in vehicle
OWNER S MANUAL US Permolock C3 Docking system for Power wheelchair in vehicle How to contact Permobil Head Office of the Permobil group Permolock C3 Docking system for electric wheelchair in vehicle Produced
Companion Service Guide
Companion Service Guide This Service Guide contains: Troubleshooting Replacement Instructions Contact Information Golden Technologies 401 Bridge Street Old Forge, PA 18518 Toll-free: 800-624-6374 Fax:
Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Manual. Simrad StructureScan LSS-1 Sonar Module. English
Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the
CX Zoner Installation & User Guide
CX Zoner Installation & User Guide Cloud Electronics Limited 140 Staniforth Road, Sheffield, S9 3HF England Tel +44 (0)114 244 7051 Fax +44 (0)114 242 5462 e-mail [email protected] web site http://www.cloud.co.uk
e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL
Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases
Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in
Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2
Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
430 Power/Electronics Replacement
Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a