DEALER SERVICE BULLETIN
|
|
|
- Ralph Rodgers
- 9 years ago
- Views:
Transcription
1 DEALER SERVICE BULLETIN Number: DSB Date: 4/1/14 Supersedes: DSB A Revised 9/17/12 Title: Bristol Two Stage Compressor or Unit Replacement Program PRODUCT CATEGORY: Heat Pumps and Split System AC MODELS AFFECTED: Bryant: 698B, 598B, 286A, 187A Carrier: 38YDB, 38TDB, 25HNA6, 24ANA7 Serial Number(s): All serial numbers within 10 years of unit production date as indicated by the unit serial number. **Commercial installations are not eligible for the program.** SITUATION: This bulletin sets forth the modified replacement program for Bristol two stage compressors or complete outdoor units due to a compressor failure occurring on or after April 1 st, 2014 IF such failure occurs within 10 years of the unit production date. The Bristol two stage reciprocating compressor has undergone continuous improvements to extend its long term reliability, but is more sensitive to certain operating conditions than a scroll compressor. Oversized equipment, improper airflow and charging issues are a few examples of applications and operating conditions that can cause additional stress on the system s components, including the compressor. SOLUTION: All claims will be submitted directly into the Service Bench Warranty System by the distributor. The Bristol Audit Form must be signed by the homeowner and is required to be held indefinitely at distribution for potential factory audit. The customer has a choice of 2 options: Option 1: Compressor replacement without optional labor contract Carrier provides the replacement compressor and associated parts and pays a $200 dealer allowance for labor cost. The replacement compressor and associated parts assume the remainder of the standard limited warranty from the original unit installation date. Compressor replacement with optional labor contract Carrier pays a tiered optional contract labor and materials allowance for labor and miscellaneous parts (see Table #2 in Policy section below) in addition to providing the replacement compressor. The replacement compressor assumes the remainder of the standard limited warranty and the optional labor contract from the original unit installation date.
2 The following Bristol TS Compressor Part Numbers are covered under this bulletin. Prior to 2006 RCD part number Bristol model Mfg part number P K T89B284CBCA GB20PF007 P K T89B194CBCA GB20PF008 P K T89B385CBCA GB20TF004 P K T89A514BBCA GB20JF006 P K T89A514BBCA GB20JF & After RCD part number Bristol model Mfg part number P K T81J195CBCA P K T81J285CBCA P K T81J384CBCA P K T89A515BBCA Option 2: Unit replacement without optional labor contract Customer pays a tiered unit replacement buy-in (see Table #1 below). Carrier has reduced the buy-in amount charged to the consumer by $450 to assist the consumer with installation costs. The consumer is responsible for negotiating labor and any additional charges. All such costs must be paid directly to the dealer by the consumer. Customer receives a new equivalent unit with a scroll compressor The new unit assumes the remainder of the original unit s limited warranty. Distributor is invoiced for customer pay in funds according to table #1. Unit replacement with optional labor contract Customer pays a tiered unit replacement buy-in (see Table #1 below). Carrier pays a tiered optional contract labor and materials allowance for labor and miscellaneous parts (see Table #2 in Policy section below). New equivalent unit with a scroll compressor The new unit assumes the remainder of the original unit s limited or optional warranty. Distributor is invoiced for customer pay in funds according to table #1.
3 TABLE #1 Tiered buy-in for unit based on TIS (Time In Service) > 36 but less than 72 Months TIS Less than 36 Months TIS > 72 to 120 Months TIS Unit Replacement Buy-In (With Optional Labor Contract) $0.00, Labor rate per Table # 2 in Policy Section $545.00, Labor rate per Table # 2 in Policy Section $ , Labor rate per Table # 2 in Policy Section Unit Replacement Buy-In (Without Optional Labor Contract) $0.00, Carrier pays labor capped at $450 $545.00, Includes $450 reduction to help with installation costs. Customer pays labor costs to dealer $ , Includes $450 reduction to help with installation costs. Customer pays labor costs to dealer The following table identifies indoor coil models that have an approved outdoor unit match and are therefore covered under this bulletin. Approved Match: Yes/No Approved Bristol Replacement 40FK (w/puron TXV) Yes Yes * FK4 (w/puron TXV) Yes Yes * FV4A, B Yes Yes * FV4C No Yes FE4A Yes Yes * Requires replacement of the indoor motor module for correct air flow when replacing the outdoor Bristol unit with the approved replacement model. Reference SMB The following table identifies approved outdoor models that have an approved outdoor unit match and are therefore covered under this bulletin. Only the equivalent replacement to the failed unit as identified in the below chart is approved under this bulletin. No upgrades are allowed. A change in unit size (tonnage) is allowable if appropriate for the installation as long as the replacement unit is listed in the Approved outdoor replacement chart below. Approved outdoor replacement units listed below: Carrier Bristol AC Approved A/C Replacement Model Approved A/C Replacement Model (Coastal) 38TDB024 24APA724A or 24ANB724A 24ANB724C 38TDB036 24APA736A or 24ANB736A 24ANB736C 38TDB037 24APA736A or 24ANB736A 24ANB736C 38TDB048 24APA748A or 24ANB748A 24ANB748C 38TDB060 24APA760A or 24ANB760A 24ANB760C 24ANA724 24APA724A or 24ANB724A 24ANB724C 24ANA736 24APA736A or 24ANB736A 24ANB736C 24ANA748 24APA748A or 24ANB748A 24ANB748C
4 24ANA760 24APA760A or 24ANB760A 24ANB760C Bristol HP Approved HP Replacement Model Approved HP Replacement Model (Coastal) 38YDB024 25HPA624A or 25HNB624A 25HNB624C 38YDB036 25HPA636A or 25HNB636A 25HNB636C 38YDB037 25HPA636A or 25HNB636A 25HNB636C 38YDB048 25HPA648A or 25HNB648A 25HNB648C 38YDB060 25HPA660A or 25HNB660A 25HNB660C 25HNA624 25HPA624A or 25HNB624A 25HNB624C 25HNA636 25HPA636A or 25HNB636A 25HNB636C 25HNA648 25HPA648A or 25HNB648A 25HNB648C 25HNA660 25HPA660A or 25HNB660A 25HNB660C Bryant Bristol AC Approved A/C Replacement Approved A/C Replacement Model Model (Coastal) 598BNX BNA BNC BNX BNA BNC BNX BNA BNC BNX BNA BNC ANA BNA BNC ANA BNA BNC ANA BNA BNC ANA BNA BNC060 Bristol HP Approved HP Replacement Approved HP Replacement Model Model (Coastal) 698BNX BNA BNC BNX BNA BNC BNX BNA BNC BNX BNA BNC ANA BNA BNC ANA BNA BNC ANA BNA BNC ANA BNA BNC060 * Replacement models listed are valid at time of original bulletin publishing. As models are replaced over time, the replacement model may be the listed model in this bulletin OR the equivalent newer model. ** Call Customer Service for pre-approval on any Coastal replacement models. A customer signature is required on the Bristol Program Audit form to ensure that the customer was presented ALL options under the terms of this bulletin. Claims missing the customer signature can be reversed.
5 Claiming: All claims should be filed by distributor. Field Action: Diagnose the failed unit using the attached procedure and Bristol Program Audit Form. Determine if unit is eligible for program by utilizing appendix B to determine if it is within 10 years of its production date. If unit is eligible, determine customer choice for unit replacement or compressor replacement. Provide the completed Bristol Program Audit Form with the customer s signature to your distributor service manager to obtain pre-approval for replacement under this program. For additional questions: Carrier Expert Central: Bryant Solution Center: [email protected] [email protected] Customer brochures are available to help explain the program and choices to the customer. They can be ordered under the following part numbers: Carrier: Bryant: Parts: The following parts are approved for replacement under the terms of this bulletin when indicated: Contactor, Capacitor, Filter Drier, Start kit, Start Relay and Compressor Plug (Accumulator - not covered). Policy: All Bristol Compressor Claims must be filed under the terms of the SMB. Claims filed through standard warranty channels, including optional labor contracts, will be denied. This Policy will terminate June 30, 2014
6 Bristol Program Audit Form This form needs to be completed and submitted to your Distributor Service Manager for pre-authorization to replace the compressor or unit under -. All Fields Required System Information: Outdoor Unit Model / Serial Number: Compressor Model/Serial Number: Date Installed: Date Failed: Customers Name: Dealers Name: Distributors Name: Date: Customer Complaint: Compressor Capacity Loss? Does Unit Run? Below System Checks should be done in accordance to Appendix A of SMB Airflow: Was Airflow checked and is it within specification for the application? Is Static Pressure within specification? System Charge: Was system charge checked and was it within specification for the application? Is application a long line set? If YES above, have appropriate checks been done to ensure application/installation is correct for a long line set? Are there Buried Refrigerant Lines in the application? If Yes, has it been verified that no liquid slugging is occurring? Failed Compressor: Is there power to the compressor? Have the appropriate checks been done to determine that the issue is not electrical? Yes/ No / NA / NA Required: Customer was presented with all options under flyer or For compressor replacement option, customer has received a $200 dealer allowance for labor costs. For unit replacement option, customer is responsible for dealer labor costs. Homeowner signature: Distributor Name & Service Manager Service Managers Signature Is the failed unit covered with an optional labor contract? no yes Contract #:
7 Appendix A: Bristol Compressor Program Diagnostic Reference These procedures outline the steps associated with diagnosing the compressor and filling out the program claim form. Please use this section as a reference when filling out the required claim form for the program. After review of this completed Bristol Compressor Evaluation Form the Distributor Service Manager is authorized to sign and approve a replacement outdoor unit or compressor replacement under the terms of this SMB. Proof of Compressor Electrical Failure (Defined as Compressor windings electrically open, shorted or winding resistance measurements not correct. If electrically open, the internal overload may be open and steps must be taken to determine if a problem external to the compressor is the cause of the overload trip.) Important Note: Prior to testing the compressor, disconnect and lockout/tagout all electrical power to system, including indoor and outdoor power sources. Terminal Locations for winding resistance readings Run winding Terminal R Terminal #3 Common Terminal C Start winding Terminal S Checking Compressor Winding Resistance Use the symbol for Open circuit The sum of the start and run winding resistances should be equal to the value measured between R and S. Resistance reading (R to C) + (S to C) = (R to S) if not, compressor winding is damaged If R to C and S to C are open circuit and R to S has resistance, the internal overload is open. The compressor needs time to cool to allow the internal overload to close. If the overload has opened, then other problems may be present in the refrigerant system that needs to be evaluated. Some possible causes of an open internal overload include insufficient refrigerant charge, restriction in the refrigerant circuit, and power supply problems. Replacing the unit may not solve these problems.
8 Checking the start Components Place a clamp amp meter between the start relay terminal 4 and the start capacitor. With the relay closed, you should observe amperage if the relay opens amperage should disappear. Measuring the voltage across the open relay terminals (SR 6 to SR4) if the relay terminals are closed voltage should be zero (0). When the relays open a voltages should be measured at a minimum the voltage should be line voltage. How the relay works Pl4 is a three (3) pin locking header with pin 2 removed. Header is labeled sr. The connections are: pl4-1 sr connection for the start relay pl4-2 not used pl4-3 sr ground return for the start relay Start relay output sr 85ma 22vdc On Bristol compressor models, when a command for compressor run occurs, the control will energize the start relay output, energizing the start relay (external to the board) that will add a start capacitor across the run capacitor of the compressor. When a predetermined voltage level at the appropriate terminal (vs. in high capacity and vr in low capacity) has been reached the relay removes the capacitor from the circuit.
9 On all models, the presence of voltage at both vr and vs is an indication that a contactor has closed and the compressor is starting or running. When starting or running, a phase difference of the voltages on the inputs will indicate the compressor internal thermal cutout is closed. If the phase difference is <= 5 degrees for 10 seconds, the internal cutout has opened and the compressor is no longer running. If an open thermal cutout has been detected, the control will de-energize the low or hi compressor outputs, but continue to energize the odf/pwm output for 15 minutes. The status (yellow) led will flash the appropriate code. If the control does not detect a model plug or detects an invalid model plug it will not allow the unit to operate. The status (yellow) led will flash the appropriate code. Compressor start detection on Bristol models only: In low stage, if the specified start voltage at vr terminal is not achieved, the start relay is de-energized after 1 second and the control will flash the appropriate fault code. In high stage, if the specified start voltage at vs terminal is not achieved, the start relay is de-energized after 1 second and the control will flash the appropriate fault code. If the specified start voltage is not achieved for 3 consecutive low stage starts, low stage operation is locked out for 30 minutes. If the specified start voltage is not achieved for 3 consecutive high stage starts, high stage operation is locked out for 30 minutes. The control will flash the appropriate fault code. Proof of Compressor Mechanical Failure (Defined as Compressor electrically correct, but either will not operate or will operate but not pump refrigerant or will only pump at low stage capacity when the high stage control and high stage contactor are calling for high stage) Noisy units DO NOT QUALIFY for Replacement unit coverage.) WARNING: this portion of the test procedure requires electrical power be supplied to the unit. Caution should be used to prevent personal injury due to electrical shock. Testing the Capacitor Capacitor MFD = 2654 X Amps / Volts
10 Appendix B: How to determine unit eligibility based on serial number Example Unit Serial Number: 3104XXXXXX (First 2 digits are calendar week, second 2 digits are calendar year) To qualify for this bulletin, the fail date for the compressor must be within 10 years of the production calendar week. Use the calendar below to determine if the compressor fail date falls on, or before, the production calendar week.
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
COMPRESSOR REPLACEMENT PROCEDURE
COMPRESSOR REPLACEMENT PROCEDURE Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned Manual No.: 2100-003E Supersedes 2100-003D File: Volume I, Tab 1 Date: 06-25-02 Copyright
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
*.ppt 11/2/2009 12:48 PM 1
Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers
10 YEAR WARRANTY REGISTRATION PROCEDURES. Please see product warranty section in back of book for registration procedures
10 YEAR WARRANTY REGISTRATION PROCEDURES Please see product warranty section in back of book for registration procedures Carrier Systems are eligible for 10 YEAR Warranty Coverage when registered! Important
Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
AE21-1319 R6 December 2013. Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE21-1319 R6
AE21-1319 R6 December 2013 Digital Capacity Control for Copeland Scroll Refrigeration Compressors TABLE OF CONTENTS Section Page Section Page Safety Safety Instructions...2 Safety Icon Explanation...2
Infinity/ Evolution Troubleshooting Guide User Interface Software Ver. -03, -05, -06, -08, -10 and -12. Table of Contents
Software Revs 3,5,6,8, 10, 12 Infinity /Evolution Troubleshooting (Rev. 2) 10/12/2006 Infinity/ Evolution Troubleshooting Guide User Interface Software Ver. -03, -05, -06, -08, -10 and -12 Table of Contents
Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060
4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE
User s Information/Installation Instructions
Outdoor Heat Pump User s Information/Installation Instructions 13 SEER R-410A High Efficiency Split System These units have been designed and tested for capacity and effi ciency in accordance with A.R.I.
Air Conditioning Systems Warranty Manual. Version 1.8
Air Conditioning Systems Warranty Manual Version 1.8 1/2015 Air Conditioning System Warranty Contents Purpose 4 External Distribution... 4 Policies 5 Warranty Policy Overview... 5 Warranty Period... 5
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
ECM. Service Guide. www.thedealertoolbox.com
ECM Service Guide www.thedealertoolbox.com ECM Table of Contents Service Guide Working on the motor with power connected may result in electrical shock or other conditions that may cause personal injury,
Installation, Operation & Service Manual
Installation, Operation & Service Manual 0RQLWRU Pulse Monitor Software Version 1 0 1 Pulse Monitor Card Software Revision 1 4 0 Pulse Monitor Card Product Revision 0 1 0 0 February, 2007 Copyright 2007,
Technical Information
Date of last update: Oct-11 Ref: D7.8.4/1011/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors... 1
Split System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR
3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
CONTROLS KITS AND ACCESSORIES. 507240-01 12/2014 Supersedes10/2014
2014 Lennox Industries Inc. Dallas, Texas, USA CONTROLS KITS AND ACCESSORIES 507240-01 12/2014 Supersedes10/2014 Litho U.S.A. Equipment Interface Module Installation Instructions for the Equipment Interface
COMPRESSOR REPLACEMENT PROCEDURE
R-22 and R-410A COMPRESSOR REPLACEMENT PROCEDURE Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned Manual No.: 2100-003F Supersedes 2100-003E File: Volume I,
Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls
Geothermal Alliance of Illinois TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls Thermal Expansion Valve Topics Anatomy Operation Terms &
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
0150506194 C Limited 2nd through 5th Year Functional Parts Warranty During the 2nd through 5th year,haier will provide functional parts which prove to be defective due to workmanship
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE
Form 2B, Page 1 FLORIDA STATE COLLEGE AT JACKSONVILLE NON-COLLEGE CREDIT COURSE OUTLINE COURSE NUMBER: ACR 0100 COURSE TITLE: PREREQUISITE(S): COREQUISITE(S): Basic Electricity and Schematics None None
EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY LIMITED LIFETIME WARRANTY
EXTENDED 10 YEAR LIMITED LIFETIME WARRANTY Spectrum Manufacturing warrants that the heat pumps and air handling equipment (if purchased with a Water to Water System) manufactured by Spectrum Manufacturing
Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO
RESCUE EcoTech Direct Drive Blower Motor The High Efficiency ECM/BPM Drop-in Replacement Blower Motor Agenda Features and Benefits Product Overview Installation Overview Sales Strategy Overview FPO High
Limited Warranty. BARD MANUFACTURING CO., INC. BRYAN, OHIO 43506 Dependable quality equipment... since 1914
Limited Warranty For units applied within the United States (including Puerto Rico), Canada and Mexico Limited Warranty To Original Purchaser: Bard Manufacturing Company, Inc. Bryan, Ohio 43506 warrants
HVAC Claims: Repair vs. Replacement
HVAC Claims: Repair vs. Replacement Curtis M. VanNess Field Operations Manager Outline Brief history of HVAC How do HVAC systems work? Types of systems and equipment Causes of failure Repair vs. Replace
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
E2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY
SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL
Customized Assessment Blueprint
Customized Assessment Blueprint HVAC Installer Basic - Test Codes: 7906 and 7796 Measuring What Matters Competencies and Skills Tested in this Assessment: HVAC Theory Heat Theory and Refrigeration HVAC
Split System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Electric Motor Brake Horsepower Calculations
Electric Motor Brake Horsepower Calculations By Norm Christopherson These motor calculations are contained here as they apply to the changing conditions of the blower motor when pulley adjustments are
Split System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
EET272 Worksheet Week 8
EET272 Worksheet Week 8 answer questions 1-5 in preparation for discussion for the quiz on Monday. Finish the rest of the questions for discussion in class on Wednesday. Question 1 Questions We will now
It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.
The System Evaluation Manual and Chiller Evaluation Manual have been revised and combined into this new book; the Air Conditioning and Refrigeration System Evaluation Guide. It will be available soon as
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications
Application Engineering
Application Engineering February 2012 Digital Capacity Control for Copeland Scroll Refrigeration Compressors INDEX Page 1. Introduction... 1 2. Theory of Operation... 1 3. Nomenclature... 1 4. Digital
SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
MP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
APPLICATION GUIDELINE & SERVICE MANUAL R 410A & R 22 Split System AC & HP
APPLICATION GUIDELINE & SERVICE MANUAL TABLE OF CONTENTS PAGE PAGE UNIT IDENTIFICATION... 2 REFRIGERATION SYSTEM REPAIR... 24 26 SAFETY CONSIDERATIONS... 4 INTRODUCTION... 4 INSTALLATION GUIDELINE... 4
HEAT SIPHON ANSWERBOOK
ERROR CODES -Displayed on Player Board There are three different types of error codes displayed by the Digital Player Controller" 1 WARNING CODE - The Warning Code is displayed for the duration the error
Service and Maintenance. SEW-EURODRIVE Driving the world
SEW Brakes Service and Maintenance 2 Objectives Upon completion of this session, you will be able to do the following: - Identify the components of an SEW brakemotor - Explain the operation of the SEW
CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
Residential electric heating and cooling rebates
Rhode Island Residential electric heating and cooling rebates Save energy and money, improve comfort, and make your home better with these energy savings offers for residential electric customers. n Systems
Control of Hazardous Energy Equipment-Specific Lockout/Tagout Procedure (ELP) Template Instructions
Control of Hazardous Energy Equipment-Specific Lockout/Tagout Procedure (ELP) Template Instructions Note Only one ELP is required for identical equipment set up in an identical configuration. The template
ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products
ECM Motors Manufactured By Regal Beloit Products and Applications- What s an ECM? ECM 2.3 series ECM 142 Arktic ECM 58mm Arktic ECM 59 Arktic SSC2 Arktic 51 GEXPRO Regal Beloit s distribution arm for all
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
Miami Heat Pump HP Series Installation Guide
CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source
OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (single phase) ACCESSORIES PART NUMBER IDENTIFICATION GUIDE
OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (single phase) Digit Position: 1 2 3 4 5, 6 7 8 9 10 11 12 Example Part Number: N 4 A 3 18 A K B 1 0 0 Product Family 4 = R 410A REFRIGERANT A = Air Conditioner
GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)
FEATURES & APPLICATIONS Inexpensive 2 wire to 3 wire start controller for electric start high speed gas generators. Optimized for use with Outback Invertors. Supports three types of 3 wire generator control
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE Protected by one or more of the following U.S. Patents (3,507,354; 3,575,234; 3,596,936; 3,605,797; 3,685,329; 4,045,977; 4,698,982; 926,673 and
Hoshizaki America, Inc.
Hoshizaki America, Inc. Stackable Crescent Cuber Models KM-1301SAH/3, SWH/3, SRH/3 KM-1400SWH-M, SWH3-M KM-1601SAH/3, SWH/3, SRH/3 KM-1900SAH/3, SWH/3, SRH/3 KM-2100SWH3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3,
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
Arc Flash Avoidance and its Application to Overhead Traveling Cranes
Arc Flash Avoidance and its Application to Overhead Traveling Cranes Whitepaper August 2012 Jason Wellnitz, Controls Product Manager Material Handling Numerous technical papers, bulletins, magazine articles
Fan Coil EC Motor Control
Fan Coil EC Motor Control G3 PWM BARD The Enviro-Tec Generation 3 PWM (G3 PWM) board provides a pulse-width modulated (PWM) signal to the EC motor to control fan speed. The board is factory programmed
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500
Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500 Description Firetrol FTA1500 Primary Resistance Fire Pump Controllers use resistors in the line to reduce line voltage
How To Warranty A Car From Nordyne
Warranty Program NORDYNE offers an Expressed (Limited) Warranty on all products that it manufacturers and/or sells. This warranty is extended to the end user (Consumer) of the product. The warranty is
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Installation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.
Introduction. Motor Types
QwikSEER+ Theory of Operation and Retrofit Potential Mainstream Engineering Corporation Rockledge, FL 32955 http://www.qwik.com/products/qwikseer/index.jsp Prepared by Robert P. Scaringe and R. Paul Roth
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
The Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014
ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014 Explanation of the refrigeration cycle. Compressors. Benefits and operating characteristics. -Reciprocating
Appliance Diagnostic Modes Microwave. GE Consumer & Industrial Technical Training
Appliance Diagnostic Modes Microwave GE Consumer & Industrial Technical Training Range Table of Contents General Microwave JVM230/240/250B Series (#31-20100) JVM2070 Series (#31-9111) ZMC3000B Series (#31-1461)
Generator Warranty On-Line System Documentation
Generator Warranty On-Line System Documentation INDEX ** Use control key and click on topic to advance to that section in the document 1. Warranty Repair Claims 2. Failed Part Claims 3. Sales Consideration
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List... 4. Control Panel.
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists
For Models #6-5001, #6-7501, #10-7501 & #10-12K1
EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE
INSTALLER'S GUIDE. Supplementary Electric Heaters 18-GJ08D1-1. Table of Contents
INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Models: BAYEAAC051A BAYEAAC05LG1A BAYEAAC081A BAYEAAC08LG1A BAYEAAC101A BAYEAAC10LG1A BAYEABC151A BAYEABC201A
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.
EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board. This Troubleshooting Guide covers the electric coolant valve and control
ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual
QUALITY STEAM SPECIALTIES SINCE ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual Section: C500 Bulletin: C500.40 Date: 06-26-01 Supersedes: New PRODUCT DESCRIPTION: The Clark-Reliance
Warranty Service Policy Guide For Manufactured Housing
Warranty Service Policy Guide For Manufactured Housing DECLARATION Style Crest, Inc. is the Exclusive Master Distributor for Unitary Products Group (UPG), of furnaces, air conditioners, and heat pumps
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION
SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content
HEAT HEAT COOL HEAT PUMP COOL
OWNER S MANUAL RESIDENTIAL THERMOSTAT P/N P374-1800 HEAT COOL HEAT PUMP Su AUTO 0I20: Pm 74 COOL HEAT 27 7-DAY MABLE DIGITAL THERMOSTAT 3 Configurable Outputs Accepts Optional Humidity Module: Control
Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.
R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS
Dealer Sales & Service Guide
Analog Models w/thermostat or Timerstat Heat Siphon Not Starting 1 BREAKER TRIPPED - Check Breaker Box for correct size breaker Breakers: EX; Domestic model 2.25hp (20amp) 3.25hp (40amp) 5hp (50amp) check
Extended Warranty Handbook
Contact Information: Standard Trane Warranty Company ( STWC ) P.O. Box 9035 Tyler, TX 75711-9035 USA Phone: (800) 554-8005 Fax: (903) 579-8054 Email: [email protected] Website: www.asdealernet.com This Extended
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,