Compool. Cp3000 POOL-SPA CONTROL SYSTEM Installation & Operating Instructions 01/01/
|
|
|
- Winifred Robertson
- 9 years ago
- Views:
Transcription
1 Compool Cp3000 POOL-SPA CONTROL SYSTEM Installation & Operating Instructions 01/01/
2
3 Table of Contents SAFETY NOTICE... 1 INSTALLATION... 2 PLUMBING REQUIREMENTS... 3 EQUIPMENT LOCATION... 4 HIGH VOLTAGE WIRING... 5 LOW VOLTAGE WIRING... 9 SYSTEM OPTIONS SYSTEM START-UP CALIBRATING TEMPERATURE SENSORS OPERATING INSTRUCTIONS INTRODUCTION SAFETY FEATURES Cp3000 CONTROLLER PROGRAMMING Lx3000 POWER CENTER VALVE ACTUATORS SPA-SIDE REMOTE SYSTEM OPTIONS MAINTENANCE PROBLEM SOLVING WARRANTY INDEX... 40
4 Safety Notice SAFETY NOTICE IMPORTANT SAFETY INSTRUCTIONS WHEN INSTALLING AND USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL INSTRUCTIONS. WARNING: TO REDUCE THE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE THIS PRODUCT UNLESS THEY ARE CLOSELY SUPERVISED AT ALL TIMES. WARNING: WATER IN EXCESS OF 100 FAHRENHEIT MAY BE HAZARDOUS TO YOUR HEALTH. A TERMINAL BAR (MARKED FOR EQUIPMENT GROUND ONLY) IS LOCATED INSIDE THE HIGH VOLTAGE COMPARTMENT OF THE POWER CENTER. TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS TERMINAL MUST BE CONNECTED TO THE GROUNDING MEANS PROVIDED IN THE ELECTRICAL SUPPLY PANEL WITH A CONTINUOUS COPPER WIRE EQUIVALENT IN SIZE TO THE CIRCUIT CONDUCTORS SUPPLYING THIS EQUIPMENT. SAVE THESE INSTRUCTIONS. 1
5 Installation INSTALLATION PRODUCT PACKAGE Open the shipping carton and check the contents. If any items are missing or damaged, contact your dealer immediately. The package should include the following items: CP-3000 Controller. LX-3000 Power Center. CVA-24 Valve Actuators (2 qty). FRE-2T 3-Port Freedom Valves (2 qty). 6COND Hookup Cable (150 ft.). Installation Hardware Kit: ½ Encloser Screws (4 qty) 1¼ Mounting Screws (3 qty) Plastic Mounting Anchors (3 qty) Water Temperature Sensor (w/ Hardware) 2-conductor Hook-up Cable (25 ft.) Modular Plugs for Communication Cable (3 qty) Test Cable with Modular Plugs (4 ft.) SPECIAL TOOLS REQUIRED 1. 3/16 dia. Drill (for mounting Cp3000 Controller). 2. 5/16 dia. Drill (for mounting Water Temperature Sensor). 3. Crimping Tool (model TOOL-6) for mounting Connectors to Hookup Cable. TOOL-6 2
6 Installation PLUMBING REQUIREMENTS CP-3000 CONTROLLER LX-3000 SERVICE CENTER SOLAR SENSOR VACUUM RELIEF HW-5B SOLAR PUMP FILTER PUMP FILTER WATER SENSOR CVA-24 HEATER SPA ET PUMP AIR INTAE BLOWER SPA-SIDE REMOTE CVA-24 SIMMER POOL CLEANER PUMP CVA-24 CVA-24 MAIN DRAIN SPA POOL SPA WATERFALL LIGHT Recommended Hydraulic Schematic Plumb system in accordance with recommended hydraulic schematic, local codes and the following guidelines. Bring all lines back to the equipment pad: 1. Spa should be at or above the level of the pool. If spa is attached to pool, provide a dam between the two bodies of water and allow spa overflow into pool. If spa is not attached to pool, an overflow, sufficient in size to carry full pump-flow, must be installed between spa and pool. 2. Plumb a 3-port Freedom Valve on the suction-side of the filter pump, so that center port of valve is connected to the pump inlet. Connect spa suction to one side of Intake Valve, and pool suction to the other side. 3. Plumb a 3-port Freedom Valve on the output-side of the heater, so that return water will enter valve through the center port. Connect spa return to one port, and pool return to the other. 4. A ¾ spa makeup line (incorporating a ¾ manual gate or ball valve and, for elevated spas, a ¾ check valve) may be provided to bypass the pool return line. This will enable some of the pool water to cycle through the spa, thus keeping it chemically balanced with the pool. The manual valve will allow the amount of bypass to be adjusted. 5. If an optional Spa-Side Remote is to be used, install a 6 to 12 length of 1½ Sch. 40 pvc pipe above water level in the spa wall so that the Spa-Side Remote will not be submerged. This can be done by positioning the top of the 1 ½ pipe ½ below the coping. The pipe should be perpendicular to the spa wall and protrude beyond the finished surface of the spa. It will be cut back at a later date. Outside the spa, reduce the pipe size down to ½ or ¾ conduit, and run to proposed Lx3000 Power Center location at equipment pad. Use sweep elbows for turns. The Spa-Side Remote should not be installed until spa construction complete.;; is POOL LIGHT ;;; 3
7 Installation 6. For systems which incorporate a skimmer, it is possible to balance the amount of suction between the skimmer and main drain for maintenance purposes. This is easily accomplished by installing a manual 3-port Freedom Valve at the suction line. Plumb one port to the skimmer and the other to the main drain. 7. If a booster pump type pool cleaner is being used, plumb the pump so that its suction-side is connected to the pool return, after the heater and as close to the ground as practical. 8. A motorized 3-port Freedom Valve can be installed to create a waterfall from the return line. This enables a waterfall effect to occur whenever the filter pump is running, and eliminates the need for a separate pump. 9. For systems which utilize solar panels, plumb the solar feed and return lines between the filter and heater, and install a motorized 3-port Compool Solar Valve at the solar feed line. Provide a vacuum relief valve at the highest point of the solar panel array, and a ½ lb. spring check valve at the solar return line. Use Compool Solar Valve (model SOL-2T), to allow the panels to automatically drain whenever the filter pump is not running. 10. For solar systems with very long plumbing runs, or where panels are installed at a very high elevation (higher than reasonable head pressure of filter pump), a solar booster pump should be installed at the solar feed line. The motorized Solar Valve should always be used in conjunction with this pump, except where the vertical elevation of panels above pool water level exceeds 25 feet. 11. For solar systems with glazed panels, plumb a ½ motorized Solar Drain Valve (model HW-5B) from the solar feed line, through a check valve, to a zero psi point (such as a jet air intake or pool fill line). Do not connect it to pump suction. This will enable the panels to automatically drain whenever the solar turns off, even if the filter pump is still running. This prevents possible scaling of panels and damage from overheating. The Solar Drain Valve (model HW-5B) should also be used for solar systems which do not facilitate gravity drainage of panels (i.e.: where solar plumbing crosses the ridge of the roof). EQUIPMENT LOCATION With the exception of the Spa-Side Remote (which is UL Listed for installation right at the tile-line of the spa), all equipment must be located five feet or more from the water s edge. 1. Lx3000 Power Center at the equipment site. 2. Cp3000 Controller inside the house or other weather-protected area. 3. CVA-24 Valve Actuator(s) at valve(s) to be motorized. 4. TS-5L Water Temperature Sensor at the filter pump. 5. TS-5L Solar Temperature Sensor at solar panels (where applicable). 6. Spa-Side Remote (optional) at spa wall or decking. 4
8 Installation HIGH VOLTAGE WIRING SUB-PANEL At the equipment site, install an electrical sub-panel with separate breakers for each load. Circuit breakers should be readily accessible to the pool/spa user, but installed at least 5 feet from the water s edge. Note: It is possible to install system without a sub-panel. Lx3000 POWER CENTER Lx Select a convenient location to mount the Lx3000 Power Center. Ensure that the location is greater than 5 feet from the water s edge and no further than 15 feet from any motorized valves (otherwise Valve Actuator cables will need to be extended). 2. Mount the Lx3000 on a flat surface using appropriate screws through the three external mounting points located on the side of the enclosure. Caution: Do not drill and mount from inside the enclosure. 3. Remove the three service panel screws in right-side of Lx3000 to expose the high voltage compartment. 4. Knock-out the appropriate holes at bottom of enclosure to facilitate conduit mounting. Screw terminals are provided for high voltage connections. 5
9 Installation SYSTEM POWER 1. Provide a separate circuit breaker to power the system. Either 115 or 230 VAC can be used (115 VAC is preferable). The Cp3000 system draws less than 1 amp. Caution: Incorrect system wiring will cause permanent damage to the transformer. 2. Verify that the breaker will open all ungrounded supply conductors to comply with section of the National Electrical Code, ANSI/NFPA Run appropriate wires from circuit breaker to high voltage compartment of Lx3000, and connect to top terminal block in accordance with wiring label, which is marked SYSTEM POWER. The diagram above shows system wired for 115 volts. 4. For 115 VAC, connect to Screw Terminals #2 and #3. 5. For 230 VAC, connect to Screw Terminals #1 and #3. 6
10 Installation EQUIPMENT POWER LINE LINE R LINE LINE R LINE LINE R3 LINE LINE R LINE LINE R LINE LINE R LINE LINE R FULL 0AMP LOCKED ROTOR 0AMP HIGH VOLTAGE RELAYS 1. Install circuit breakers to provide voltage for power relays at R1 through R4. Run appropriate wires from breakers to high voltage compartment of Lx3000, and connect to LINE 1 and LINE 2 Screw Terminals at each terminal block. 2. Pumps and other high voltage equipment are connected to 1 and 2 terminals. Each individual terminal block can be wired to operate either 115 or 230 VAC. 3. Connect the high voltage equipment to 1 and 2 terminals at each terminal block. The diagram above shows the high voltage wiring of a 230 VAC filter pump. 4. If the system is to control a pool cleaner pump, it should be connected to the R2 terminal block. Note: For 115 VAC equipment, only half of the terminal block needs to be used (i.e.: LINE 1 and 1). The neutral wire connects directly from the sub panel to the equipment. ADDING RELAYS The Cp3000 system comes standard with 4 power relays for activating the Filter Pump, Aux1, Aux2 and Aux3 circuits. It is possible to install additional Relay Kits (model RLY-LX) to the Lx3000, in order to activate additional equipment. Install RLY-LX in accordance with instructions provided, and plug relay control wire into Lx3000 circuit board at appropriate Relay Socket. The Lx3000 Power Center will accommodate a maximum of 7 power relays. 7
11 Installation UNDERWATER LIGHTS LINE LINE R LINE LINE R LINE LINE R3 LINE LINE R LINE LINE R LINE LINE R LINE LINE R FULL 0AMP LOCKED ROTOR 0AMP HIGH VOLTAGE RELAYS If the system incorporates 115 Volt Underwater Light(s), you should provide GFCI protection on the load side of the relay (not the line side) as shown above. Note: Low voltage lights and fiber optic lights do not require GFCI protection. 1. Run appropriate wire from circuit breaker to LINE 1 of terminal block. 2. Run wire from 1 and neutral wire from circuit breaker to GFCI. 3. Connect underwater lights to GFCI. Note: If total load exceeds 500 watts (i.e.: two 400 watt pool lights), provide a jumper wire between LINE 1 and LINE 2 at the terminal block. 8
12 3 3 Compool Cp3000 Installation LOW VOLTAGE WIRING VLV1 WITH O N VLV2 VLV2 WITH VLV3 COMPOOL 11040A MOD-VLV3 VLV1 VLV2 VLV3 AUXILIARY VALVE ACTUATORS TRANSFORMER CONNECTIONS PC-LX3000 FREEZ PORT HI SPD FEATURES FLTR AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 SPA FLTR SOLR AUX1 SOLAR MANHT ON ON ON INT VLV RET VLV SOL VLV SPA INTAKE VALVE ACTUATOR RETURN VALVE ACTUATOR SOLAR VALVE ACTUATOR COMPOOL 10890D CAUTION: DO NOT SHORT PINS OF RELAY SOCKETS FLTR AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 RELAY CONNECTIONS GAS VALVE CONTROL HEATER ON OFF PRESSURE LIMIT THERMOSTAT GRN RED GRN RED SOLAR SENSOR WATER SENSOR SELECT 4 CIRCUITS to CP-3000 BLK RED YEL GRN BLU ORG EHTR SOL PMP 2SPD HTR GND SPA REMF REM1 REM2 REM3 REM4 REM5 REM6 HBST HLMP +10 STS- STS+ WTS- WTS+ TO CP-3000 S S S 3 S BLU BLU LOW VOLTAGE CABLES to SPA-SIDE REMOTE Lx3000 Circuit Board All low voltage connections are made to the circuit board which is located behind the hinged faceplate in left-side compartment of Lx3000 Power Center. 150 feet of 6-conductor communication cable (model 6COND), and 25 feet of 2-conductor cable (model 2COND) is provided with the system. Additional cable is available from your distributor. Determine lengths of hookup cable required to run from the low voltage compartment of the Lx3000 Power Center to the various pieces of equipment: 9
13 Installation 1. 6-conductor 26 AWG communication cable to the Cp3000 Controller. Note: 300 run maximum. Call Compool for instruction for longer runs. Caution: Always lubricate cable with cable lubricant when pulling through conduit conductor 22 AWG cable to the gas heater conductor 22 AWG cable to the Water Temperature Sensor conductor 22 AWG cable to optional Solar Temperature Sensor. 5. CVA-24 Valve Actuators are provided with 15 feet of 3-conductor cable. Note: May be extended to a max. length of 150 w/ 18 gauge cable (model 3COND/VOR). 6. Optional Spa-Side Remote is provided with necessary cable attached (50, 100, 150, 200, or 250 length). Note: Do not install low voltage and high voltage wires in the same conduit. Do not install temperature sensor and gas heater wires in the same conduit. Install cables, using plastic or metallic conduit where cables run underground, through concrete, etc. MOUNTING THE Cp3000 CONTROLLER 1. Select a convenient location inside the house or other weather-protected area to mount the Cp3000 Controller. The overall width of the Controller (with doors open) is 11½. The location of the 6-conductor communication cable (on the centerline of the enclosure) should therefore be at least 5¾ from any door jamb, wall corner or other obstacle. Install the Cp3000 Controller at eye level for best viewing of the LCD display. 2. Remove backplate from Controller. Temporarily pull cable through large hole in backplate, and position backplate on surface of wall. Ensure that backplate is level, and that TOP nomenclature is oriented correctly. Level the backplate and mark the three mounting points on the surface of the wall. 3. With the backplate removed from the wall, drill 3/16 diameter holes at the three points. Insert mounting anchors (included) into the three holes. 4. Pull cable through large hole in backplate, and use the three 1¼ screws to mount backplate to wall. Cut off excess cable, and use crimping tool (model TOOL-6) to connect modular plug at each end of cable. See USING THE CRIMPING TOOL for details. 5. At the Cp3000, insert cable (with modular plug attached) into circuit board at LINE TO LX Socket. 10
14 Installation 6. Use the four ½ screws (included) to mount Controller to the backplate. 7. At the Lx3000, insert cable (with modular plug attached) into circuit board at to CP-3000 Socket. USING THE CRIMPING TOOL TOOL-6 1. Use Cutter to prepare cable end. Make sure that cable is cut squarely (not diagonally). 2. Insert the cable between the Stripper blades of the tool until it touches the stop. Squeeze the handles and pull the tool, making sure that the cable stays perpendicular to it. If this is done correctly, the outer jacket of the cable will be removed without damaging the insulation on the individual conductors. 3. Plug a modular connector into the holder so that the gold contacts face the Crimper. 4. Orient the prepared cable so that the blue conductor is closest to the tool handles, and insert cable into connector. Make sure the wires go all the way to the back of the connector. 5. Squeeze the handles firmly to set the contacts and secure the cable. Note: It is important that the orientation (blue conductor closest to tool handles) is identical at each end of the cable. CVA-24 VALVE ACTUATORS CVA Remove knob, handle and four screws from cap of valve(s) to be motorized, and use the four mounting screws provided to mount Valve Actuator(s) to valve(s). 2. Run cable(s) to low voltage compartment of Lx3000 Power Center. 3. At the Lx3000, plug cable(s) into appropriate Valve Socket on circuit board: 11
15 Installation Plug Intake (suction) Valve to INT VLV Socket. Plug Return Valve to RET VLV Socket. Plug Optional Solar Valve (if applicable) to SOL VLV Socket. Note: To control additional valve actuators, see AUXILIARY VALVE ACTUATORS for details. GAS HEATER CONNECTIONS Follow these instructions to connect a gas heater (millivolt or electronic-ignition) or propane heater: 1. Cut sufficient 2-conductor cable (25 ft. is included with Accessory Kit) to run between the heater and the Lx Inside the heater, interrupt wire between thermostat and pressure switch (where fireman s switch is typically connected), and interconnect with 2-conductor cable using wire nuts. Do not disconnect or bypass the thermostat or any safety switches. 3. Run cable to low voltage compartment of Lx3000. At the Lx3000, strip insulation ¼ and connect to circuit board at the two HTR Screw Terminals. 4. Turn the heater switch to ON (or High) and set thermostat(s) to maximum. WATER TEMPERATURE SENSOR 1. Select a convenient location to mount the Temperature Sensor (model TS-5L) between the pump and filter. 2. Drill a 5/16 diameter hole in the pipe, and insert the Sensor. Position the hose clamp over the Sensor, and gently tighten around pipe. Caution: Overtightening of clamp can cause deformation of O-ring seal. 3. Use the remainder of the 2-conductor cable (provided with Accessory Kit) to run between Sensor location and low voltage compartment of Lx3000 Power Center. 4. At the Sensor, pay attention to color-coding of wires (green wire connects to green; red wire connects to red), and use crimp connectors (included) to provide waterproof connections. Before making connections, shorten sensor 12
16 Installation leads to about 6. Do not strip wires. Push the 2 wires to be connected into the small holes at one end of the connector, and squeeze the connector with a pair of pliers. 2 extra connectors are included. 5. At the Lx3000, connect Sensor cable to circuit board at WTS- and WTS+ Screw Terminals in accordance with wiring diagram located inside Lx3000 door. Pay attention to color-coding of wires (green wire connects to WTS- and red wire connects to WTS+). Note: Infield calibration of temperature sensor(s) is required. See CALIBRATING TEMPERATURE SENSORS for details. 13
17 Installation SYSTEM OPTIONS SPA-SIDE REMOTE SS4-100W The optional Spa-Side Remote (model SS4-100W) is a double-insulated device which is UL Listed for installation within 5 feet of the water s edge. It is typically installed at the tile-line on the spa wall (above water level), or in the deck within arm s reach of the spa. If the Spa-Side Remote is to be installed into the wall of a gunite spa, provision must be made while the spa is being plumbed (See PLUMBING REQUIREMENTS for details): 1. When the spa construction is completed, cut back the 1½ dia. pvc pipe receptacle flush with the spa wall finish or surface of deck. 2. Screw Mounting Adapter onto Spa-Side Remote, and finger-tighten. Caution: Do not use wrench. 3. Thread Spa-Side Remote cable through conduit to low-voltage compartment of Lx Carefully glue Mounting Adapter into 1½ pvc receptacle using pvc cement. For aesthetic purposes, it is suggested that the Spa-Side Remote be installed with Red button in the 12 o clock position. 5. At the Lx3000, identify the 6-conductor cable from the Spa-Side Remote, and cutoff excess cable as necessary. Strip insulation of each conductor ¼" and connect to appropriate Screw Terminals at bottom of circuit board in accordance with wiring diagram: 6. Connect Black wire (Switch Common) to GND Screw Terminal. 7. Connect Orange (Status Lamp) to HLMP Screw Terminal. 8. Determine which 4 of the following circuits you wish to control from within the spa, and connect Red (Red button), Yellow (Yellow button), Green (Green button) and Blue (Blue button) wires to the appropriate Screw Terminals (see LX3000 CIRCUIT BOARD for details): SPA Rotates intake and return valves, and activates filter pump and heater. REMF Activates filter pump (normally not used). REM1 Activates auxiliary 1 equipment (such as pool cleaner). REM2 Activates auxiliary 2 equipment (such as pool light). REM3 Activates auxiliary 3 equipment (such as spa light). REM4 Activates auxiliary 4 equipment (such as fountain or waterfall). REM5 Activates auxiliary 5 equipment (such as jet pump). REM6 Activates auxiliary 6 equipment (such as air blower). HBST Enables spa heating for a five minute period. For Spa-Side control of more than 4 pieces of equipment, a second Spa-Side Remote may be installed. 14
18 Installation A set of adhesive labels is provided for custom identification of individual Spa-Side Remote buttons. Use a pair of fine-tip tweezers to carefully adhere the appropriate label at each button. 2-SPEED FILTER PUMP CONTROL If the system is equipped with a 2-Speed Filter Pump, a 2-Speed Filter Pump Relay Kit (model RLY-LXD) should be installed at the Power Center in accordance with instructions provided. There are three ways to configure the 2-Speed Filter Pump control: 1. Automatic configuration: The system will run the filter pump in low speed during normal operation, but will automatically switch the pump to high speed for 5 minutes whenever the filter pump turns on. It is additionally possible to activate the pump in high speed whenever the spa, heater, solar and/or Aux1 (pool cleaner) is running. To enable the pump to run in high speed during these conditions, it is necessary to adjust the 4- position HI SPD Program Switch, which is located at top center of Lx3000 circuit board. Use the corner of a small screwdriver or other blunt instrument to slide the appropriate Switch(es) to the ON position: Switch #1: Switch #2: Switch #3: Switch #4: Enables high speed when spa is running. Enables high speed when heater is running. Enables high speed when solar system is running. Enables high speed when Aux1 (pool cleaner) is running. Connect RLY-LXD relay control wire into 2SPD Relay Socket. 2. Manual configuration: The system will run the filter pump in low speed during normal operation, but will switch the pump to high speed when an Auxiliary Circuit is activated. Select an Auxiliary Circuit (Aux1 - Aux6), and connect RLY-LXD control wire into the appropriate Relay Socket. 3. Combined configuration: The high speed is controlled by an Auxiliary Circuit and the HI-SPD Program Switch. Use Dual Circuit Relay Adapter (model CRA-LX) to connect RLY-LXD relay control wire into an Auxiliary Relay Socket and into 2SPD Relay Socket. AUXILIARY VALVE ACTUATORS VLV1 WITH VLV2 O N 1 2 VLV2 WITH VLV3 COMPOOL 11040A MOD-VLV3 CONTROL JUMPER SOCKETS VLV1 VLV2 VLV3 AUXILIARY VALVE ACTUATORS MOD-VLV3 It is possible to add Valve Actuators (model CVA-24) to the system to motorize two-port or three-port valves for custom hydraulic features (such as a pool cleaner, fountain, waterfall, etc.). A total of three Valve Actuators may be added. Valve Actuators can be activated from any Circuit. 1. Install Auxiliary Valve Module (model MOD-VLV3) at the Lx3000 low voltage compartment in accordance with instructions provided. 15
19 Installation 2. Remove knob, handle and four screws from cap of valve(s) to be motorized, and use the four mounting screws provided to mount Valve Actuator(s) to valve(s). 3. Run cable from Valve Actuator to Lx3000 low voltage compartment. 4. Plug end of Valve Actuator cable(s) into appropriate Valve Socket(s) on the MOD-VLV3 circuit board (VLV1, VLV2, or VLV3). 5. Locate Wiring Harnesses, which are provided with the Valve Module. 6. Select which Circuit(s) you wish to use for activating Valve Actuator(s). Each Circuit will require a Wiring Harness. 7. Plug one end of Wiring Harness into Lx3000 circuit board at the appropriate Relay Socket. 8. Plug other end of Wiring Harness into MOD-VLV3 at appropriate CONTROL JUMPERS Socket. 9. To combine the operation of VLV1 with VLV2 and/or VLV2 with VLV3, adjust the COMBINED VALVES Program Switch (at upper left-side of MOD-VLV3) accordingly. HIGH VOLTAGE THERMOSTAT HEATER For systems which utilize a high voltage thermostat, such as an oil fired heater, electric heater, or heat pump, a Relay Kit (model RLY-LX) should be added. 1. Install RLY-LX at the Lx3000 in accordance with instructions provided, and plug relay control wire onto circuit board at EHTR Relay Socket. The relay will close whenever the Cp3000 is calling for heat. 2. Splice thermostat wiring inside heater and run wires of sufficient gauge to Line 1 and Load 1 of RLY-LX relay terminal block. FREEZE PROTECTION SETTINGS It is possible to automatically circulate water through the equipment whenever the temperature drops to 35 F. This will protect the equipment against possible freeze damage. The Control System uses the Water Temperature Sensor to detect freezing conditions, so a separate Freeze Sensor is not required. It is, however, necessary to adjust the 7-position FREEZ PROT Program Switch, which is located at top center of Lx3000 circuit board. Determine which equipment you would like to activate during freezing conditions, and use the corner of a small screwdriver or other blunt instrument to slide the appropriate Switch(es) to the ON position: Switch #1: Switch #2: Switch #3: Switch #4: Switch #5: Switch #6: Switch #7: Activates FLTR (filter pump) during freezing conditions. Activates AUX1 during freezing conditions. Activates AUX2 during freezing conditions. Activates AUX3 during freezing conditions. Activates AUX4 during freezing conditions. Activates AUX5 during freezing conditions. Activates AUX6 during freezing conditions. When Freeze Mode starts, the Cp3000 display will indicate FRZ and turn on any circuit that has been selected by the FREEZ PROT Program Switch. Equipment key icons will not show ON if activated by the Freeze Mode. Switch #1 additionally cycles the pool and spa for 15 minutes each. The Freeze Mode lasts for 30 minutes. Pressing 16
20 Installation any of the equipment keys on the Cp3000 controller will deactivate the Freeze Mode. SOLAR TEMPERATURE SENSOR If the system incorporates solar, install an optional Temperature Sensor (model TS-5L) at the solar panel array. 1. Adjust the 2-position Program Switch, which is located at top center of Lx3000 circuit board. Use the corner of a small screwdriver or other blunt instrument to slide Switch #1 (SOLAR) to the ON position. 2. Discard clamp (included with TS-5L). Do not drill hole and clamp sensor into solar pipe. For unglazed panels, fasten Sensor to surface next to solar panels. Do not bolt directly to panel. For glazed panels, suspend Sensor between collector and glazing. 3. Provide 2-conductor cable between Solar Sensor and low voltage compartment of Lx3000 Power Center. 4. At the Sensor, pay attention to color-coding of wires (green wire connects to green; red wire connects to red), and use crimp connectors (included) to provide waterproof connections. Before making connections, shorten sensor leads to about 6. Do not strip wires. Push the 2 wires to be connected into the small holes at one end of the connector, and squeeze the cylinder with a pair of pliers. 2 additional connectors are included. It is recommended to tape connections and wiring to prevent possible damage from UV radiation. Be sure to keep wires separated. 5. At the Lx3000, connect cable from Solar Sensor to circuit board at STS- and STS+ Screw Terminals. Pay attention to color-coding of wires (green wire connects to STS- and red wire connects to STS+). Note: Infield calibration of temperature sensors is required. See CALIBRATING TEMPERATURE SENSORS for details. SOLAR BOOSTER PUMP CONTROL If a solar booster pump is being used, install a Relay Kit (model RLY-LX) at the Lx3000 in accordance with instructions provided, and plug onto circuit board at SOL PMP Relay Socket. 17
21 Installation Cp3000 CIRCUIT BOARD COMPOOL 10881A PART No PC-CP3000 S LINE TO LX ON S2 CS FS FC CD FD RESET NORMAL To enable the following options, refer to the Cp3000 circuit board diagram shown above. SPA WATERFALL CONTROL SWITCH For systems where spa water level is higher than that of the pool, it is possible to use Circuit #2 to rotate the return valve to spa return position, thus creating an overflow (waterfall effect) from the spa into the pool. This effect will cease during spa circulation or pool cleaner operation. To enable this feature, it is necessary to adjust the 3-position S1 Program Switch, which is located at top right-side of Cp3000 circuit board. Using the corner of a small screwdriver or other blunt instrument, slide Switch #3 to the ON position. CUSTOM CLOCK OPTIONS The standard Cp3000 Controller is provided with the appropriate equipment interlock and safety delays, assuming that Aux1 Circuit is being used to activate a pool cleaner pump. It is, however, possible to eliminate the interlocks and delays for custom applications (such as where there is no pool cleaner). To achieve this, it is necessary to modify the 5-position S2 Program Switch which is located at center right-side of the Cp3000 circuit board. Use the corner of a small screwdriver or other blunt instrument to slide the appropriate Switch(es) to the OFF position: Switch #1: Switch #2: Switch #3: Switch #4: Switch #5: Filter Pump Off Delay (fireman s switch). Aux1 (Pool Cleaner) On Delay. Aux1 Pool Cleaner/Filter Interlock. Spa/Filter Interlock. Spa/Aux1 (Pool Cleaner) Interlock. If the control system does not incorporate a pool cleaner pump, Switches #2, #3 and #5 can be turned OFF, and the Aux1 Circuit can be used for another auxiliary function. SPA-SIDE COUNTDOWN TIMER A built in 30 minute countdown timer is set at the factory for Auxiliary Circuits 5 and 6. These circuits usually operate a jet pump and blower, and are controlled by the Spa-Side Remote. To disable this feature, it is necessary to modify the 3-position S1 Program Switch which is located at center right-side of the Cp3000 circuit board. Use the corner of a small screwdriver or other blunt instrument to slide the appropriate Switch(es) to the OFF position. Switch #1 will actuate Aux6; and Switch #2 will actuate Aux5. 18
22 Installation 1. Turn system power on. SYSTEM START-UP 2. At the heater, make sure that the switch is turned to the ON, High or Spa position, and that the temperature dial is turned to the highest setting. 3. At the Lx3000 Power Center, press the Auto/Service Key to switch the System to Service mode. Press the #S Key to Spa mode, and check that Valve Actuators have rotated to spa positions. If either valve is 180 out of phase, flip toggle switch on rear of Valve Actuator from ON1 to ON2 position. 4. Press the remaining Equipment Service Keys (#P, #1, #2, #3, #4, #5 and #6) to verify that corresponding equipment is being activated. 5. Press the Heater Key, and verify that the heater is firing (filter pump must be on and pumping). 6. If solar system is installed, verify program switch on the Lx3000 circuit board SOLAR is in the ON position. The Cp3000 system will only recognize the solar installation if this switch is ON (see SOLAR SENSOR for details). 7. Press the Solar Key, and check that the Solar Valve (if applicable) has rotated to solar position. If it is 180 out of phase, flip toggle switch on rear of Valve Actuator from ON1 to ON2 position. 8. Check that neither Temperature Sensor Status lamps are illuminated. If a lamp has turned on, check wiring connections to the appropriate Sensor. 9. After the equipment operation has been tested from the Lx3000, press Auto/Service Key to return System to Auto mode. 10. At the Cp3000 Controller, press each Equipment Key (#S, #P, #1, #2, #3 and #4), and check that appropriate equipment is being activated. Note: If the Auto/Service Key at the Lx3000 has inadvertently been left in the Service mode, the Service status lamp will illuminate at the Cp3000 Controller. 11. A set of adhesive labels is provided for custom identification of individual circuits. Use a pair of fine-tip tweezers to adhere the appropriate label adjacent to the Equipment Key at the Cp3000 Controller and Lx3000 Power Center. A set of labels is also provided for custom identification of the buttons at the optional Spa-Side Remote. 19
23 Installation CALIBRATING TEMPERATURE SENSORS The following infield calibration is required for the Temperature Sensor(s): 1. Use a thermometer to verify pool temperature. 2. Use a thermometer to verify solar temperature if applicable. 3. At the Cp3000 Controller, turn on the Pool and let it run for a few minutes. 4. Press the Program Key. 5. Press the Pool Heat Source Key. ADJ 1 will appear on the Display. 6. Use the Pool Temperature Keys to enter the temperature verified in Step Press the Pool Heat Source Key again. If the system incorporates a Solar Temperature Sensor, ADJ 2 will now appear on the Display. Use the Pool Temperature Keys to enter the temperature verified in step Press the Pool Heat Source Key once more to return the Display to the normal operating mode. 20
24 Operating Instructions OPERATING INSTRUCTIONS INTRODUCTION The Cp3000 is an electronic control system which is designed to coordinate and operate all of the equipment associated with your swimming pool and spa. The system is comprised of three principal components: Cp3000 Controller. Two CVA-24 Valve Actuators. Lx3000 Power Center. The Controller automatically controls and monitors the timing of all your pool and spa equipment, and the temperature of your pool and spa; the Valve Actuators switch the filter and heater from pool to spa; and the Power Center provides easy maintenance for your Pool Serviceperson. Additionally, the Control System incorporates important safety features which protect your pool equipment from accidental damage. Your system may also include a Spa-Side Remote and other options which further add to the convenience, safety, and economy of operating your pool and spa equipment. Note: It is not recommended to use the Cp3000 system to control a pool cover. SAFETY FEATURES HEATER PROTECTION A built-in electronic delay circuit automatically runs the filter pump for an additional 5 minutes whenever the system is turned off. This feature enables the heater to cool down, so that the heat exchanger and plumbing are not damaged from overheating. If the filter pump is being turned off after using the spa and the pool was not previously on, the motorized valves will remain in the spa circulation position during this 5 minute heater cool down cycle. This prevents the possibility of any cold water being cycled from the pool into the spa during this period of time. 21
25 Operating Instructions POOL CLEANER PROTECTION If your system incorporates a pool cleaner, it may have been plumbed in conjunction with the filter pump so that it must have water circulation in order to operate. The Cp3000 incorporates the following protection features against accidental pump damage, which can occur if there is no water circulation: 1. The filter pump will automatically switch to pool circulation whenever the pool cleaner is running. 2. Whenever the pool cleaner is turned on, a built-in electronic delay circuit will prevent it from running until 5 minutes of filtration have passed. This protects the cleaner pump from possible damage caused by air which may have entered the plumbing since the system was last used. 3. Your pool cleaner will automatically be switched off whenever water is being circulated to the spa. 4. If your system incorporates solar, the pool cleaner will automatically be disabled for a period of 5 minutes whenever the solar system turns on. This protects the pool cleaner from possible damage caused by residual air within the solar panels. Note: If your system incorporates a pool cleaner, your Pool Builder will have labeled Equipment Key #1 (Aux1 circuit) at the Cp3000 Controller for switching this equipment. OVERRIDING THE SAFETY DELAY CIRCUITS For testing and servicing purposes only, it is possible to override any of the safety delay circuits by pushing the CANCEL Key, which is located behind the right-side door of the Cp3000 Controller. BATTERY BACK-UP In case of a power failure, a long-life battery automatically maintains the program and clock functions of your Control System. This safeguards against the equipment operating erratically once power has been restored, and also eliminates the need to reprogram whenever there is a power failure. Cp3000 CONTROLLER Installed in a convenient location inside your house, the Cp3000 Controller gives you fingertip control of all the equipment associated with your swimming pool and spa. EQUIPMENT STATUS LAMPS There are three Equipment Status Lamps located above the Display: 22
26 Operating Instructions Heater: Indicates whenever the heater is on. Solar: Indicates whenever the solar system (if applicable) is running. Service: Indicates whenever the equipment is being operated from the equipment site (i.e. the Auto/Service Key at the Lx3000 Power Center is in the Service position). DISPLAY When the system is in the normal operating mode, the TIME OF DAY and the ON/OFF Equipment Status of each of the six Equipment Keys will be displayed. If the pool or spa is running, the actual POOL or SPA temperature will be displayed. EQUIPMENT KEYS Six Equipment Keys are provided for activating the various pieces of equipment. Your Pool Builder should have custom-labeled each Key for your specific application. To switch equipment ON or OFF, simply press the appropriate Equipment Key once. An audible beep will sound indicating the Equipment Key has been pressed. Equipment Status is indicated on the Display immediately above each Equipment Key: A solid ON indicates that the equipment has been activated. A solid OFF indicates that the equipment is switched off. A blinking ON indicates that the equipment will activate after its 5 minute safety delay has expired. A blinking OFF indicates that the equipment will turn off after its 5 minute safety delay has expired. Key #S: Rotates valves to spa circulation and activates filter pump. Activates spa heating. Disables pool cleaner (if applicable). Key #P: Activates filter pump and circulates water for pool filtration. Enables pool heating. Key #1: Activates pool cleaner (if applicable) after 5 minute safety delay. Automatically activates pool filtration if Key #P is not already turned ON. Note: If system does not incorporate a pool cleaner, Key #1 will activate auxiliary equipment (such as lighting). 23
27 Operating Instructions Key #2: Activates auxiliary equipment (such as a pool light). Key #3: Activates auxiliary equipment (such as a spa light). Key #4: Activates auxiliary equipment (such as a fountain). USING YOUR SPA To turn your Spa ON, simply press Key #S. The motorized valves will rotate to spa circulation position, the filter pump will turn on, and the heater will heat the spa to the pre-selected spa temperature. The Display will indicate the precise spa temperature, and the Heater Status Lamp will indicate whether the spa is heating or not. To turn your Spa OFF, press Key #S. The heater will automatically shut-off. Provided the system is not resuming a preset pool circulation cycle, the filter pump will continue to circulate the spa water for its 5 minutes safety delay in order to cool down the system. After 5 minutes, the filter pump will shut-off and the motorized valves will return to pool circulation position. Note: Some heaters do not require a cool down cycle, so this safety feature may be turned off. See CUSTOM CLOCK OPTIONS for details. It is possible to program the Spa, so it will automatically shut-off after a predetermined length of time. See COUNTDOWN TIMER PROGRAM for details. POOL AND SPA HEATING Concealed behind the left-side door are separate Temperature Controls for the Pool and Spa. Each control incorporates a Heat Source Key, two Temperature Keys, and four Heat Source Lamps. HEAT SOURCE KEY It is possible to heat your pool and spa using conventional heat, solar energy (if applicable), or a combination of both. Pressing the Heat Source Key will toggle through the different heating options, as follows: Off: Allows no heating. 24
28 Operating Instructions Heater: Allows heating with gas or electric heater only. Solar Priority: Allows heating with solar, but automatically switches to conventional heating when solar energy is unavailable. If your system does not incorporate solar, the Solar Priority and Solar Only options will not be available. Solar Only: Allows heating with solar only when solar heat is available. If your system does not incorporate solar, the Solar Priority and Solar Only options will not be available. Note1: Pressing the Heat Source Keys(s) does not activate the heater and solar system. Heating can only occur when the pool or spa is being circulated and desired temperature settings have not yet been satisfied. Note2: For added convenience, whenever the spa is manually activated (from either the Cp3000 Controller or the Spa- Side Remote), the Spa Heat Source Lamp will automatically switch to Heater and heating will begin. Turning the spa off will return Spa Heat Source Lamp to its previous position. TEMPERATURE KEYS The UP and DOWN Temperature Keys are used to preset your desired water temperature. As long as the Heat Source Key(s) are not in the OFF position, the pool and spa will heat up to the preset temperature(s) whenever pool or spa is being circulated. CHECKING DESIRED WATER TEMPERATURE SETTING To check the pool and spa temperature settings, press the appropriate (Pool or Spa) Temperature Key once. The preset temperature will blink on the Display for 5 seconds. SETTING DESIRED WATER TEMPERATURE To adjust the pool and spa temperature settings, press the appropriate (Pool or Spa) Temperature Key until the Display indicates your desired water temperature. After 5 seconds, the Display will automatically return to its original condition. Temperature settings can be adjusted in the normal operating mode only. FAHRENHEIT/CELSIUS TEMPERATURE DISPLAY The Temp. Display Key (located behind right-side door) will enable you to display temperatures in either Fahrenheit or Celsius. 25
29 Operating Instructions SETTING THE CLOCK To set the Display to the correct TIME OF DAY, press the Hours and Minutes Keys (located behind the right-side door of the Cp3000 Controller). Pay attention to the AM/PM symbols on the Display. 26
30 Operating Instructions PROGRAMMING DAILY EQUIPMENT OPERATING CYCLES Behind the right-side door are Keys for programming the daily operating cycles of the equipment. Programming is a set and forget procedure, which is normally implemented by your Pool Builder at the completion of the installation. Most systems only require that you program the pool filtration cycles (Key #P) and, in some cases, pool cleaning cycles (Key #1). However, it is possible to program equipment connected to any of the six Equipment Keys at the Cp3000 Controller. Before commencing programming, you will need to determine at what time you would like the equipment to turn on (START TIME), and for how long you would like each piece of equipment to run (RUN TIME). Your Pool Builder will be able to recommend the appropriate filtration and cleaning cycles for your pool and spa. BASIC PROGRAM The following example programs the Pool Filter Pump to run eight hours every day: 1. Press the Program Key to start the program. 2. Press the Equipment Key P to program the pool. 3. Press the Hours Key to set the START TIME (example 8:00 A.M.) 4. Press the Enter Key to save the START TIME. 5. Press the Hours Key to set the RUN TIME (example 8 Hours). 6. Press the Enter Key to save the RUN TIME. 7. Press the Program Key to return to the normal operating mode. 27
31 Operating Instructions MULTIPLE PROGRAMS A total of four operating cycles may be programmed each piece of equipment. To program multiple operating cycles, follow steps 1 to 6 on the BASIC PROGRAM, and then press the Equipment Key a second time. The display will indicate PROG 2, plus a blinking START TIME. Repeat steps 3 to 6 to program a second START TIME and RUN TIME. If additional cycles are desired, repeat this procedure for PROG 3 and PROG 4. Note: If only one operating cycle is programmed, PROG will be displayed. PROG 1 indicates that multiple operating cycles have been programmed for that equipment. COUNTDOWN TIMER PROGRAM It is possible to program a COUNTDOWN TIMER for any piece of equipment, so that, whenever that equipment is activated manually it will run for its predetermined length of time and then automatically shut-off. This energy saving program is particularly useful for programming the Spa to shut-off after a few hours. The COUNTDOWN TIMER is programmed by setting the START TIME to 0:00 hours and setting the RUN TIME to the desired time you wish the equipment to run. The RUN TIME can be set (in 10 minute increments) for any length of time from 10 minutes (0:10) to 23 hours and 50 minutes (23:50). This feature may be combined with any other program (i.e. if PROG 1 is already used, use PROG 2, PROG 3, or PROG 4). Note: If there is no COUNTDOWN TIMER program, the equipment will automatically shut-off after 12 hours. The following example programs the Spa to shut-off after two hours: 1. Press the Program Key to start the program. 2. Press the Equipment Key S to program the spa. 3. Press the Enter Key to save the START TIME at 0: Press the Hours Key to set the RUN TIME (example 2 hours). 5. Press the Enter Key to save the RUN TIME. 6. Press the Program Key to return to the normal operating mode. 28
32 Operating Instructions ONCE ONLY PROGRAM It is possible to program a ONCE ONLY program for any of the Equipment Keys on the Cp3000. When a ONCE ONLY program is executed, it is erased automatically. This feature is useful to program the Spa in advance so it will be ready for use within a 24 hour period. With this convenient feature, there is no need to de-program the spa after use. The ONCE ONLY program simply erases itself. Follow the standard programming procedure to Step 3, enter a START TIME only. Do not enter a RUN TIME (RUN TIME should indicate 0:00). Press Program Key to return to the normal operating mode. This feature may be combined with any program (i.e. if PROG 1 is already used, use PROG 2, PROG 3, or PROG 4). REVIEWING THE PROGRAM(S) To review the programmed operating cycle(s) of any piece of equipment: 1. Press the Program Key. The Display will indicate PROG (to show that Clock is in programming mode), plus a row of blinking icons located immediately above the six Equipment Keys. 2. Press the appropriate Equipment Key (either #S, #P, #1, #2, #3 or #4). The icon above the Equipment Key will stop blinking, the remaining icons will disappear, and the programmed START TIME (blinking) and RUN TIME will be displayed. 3. The appearance of PROG 1 on the Display indicates that there is more than one operating cycle programmed for this equipment. To review additional program(s), press Equipment Key again. 4. If you wish to review the operating cycle(s) of another piece of equipment, return to Step 2 (i.e. press the appropriate Equipment Key). 5. When you have finished reviewing the various pieces of equipment, press the Program Key to return the Clock to normal operating mode. CANCELING PROGRAM(S) It is possible to cancel one or more of the programmed operating cycles: 1. Press the Program Key. The Display will indicate PROG (to show that Clock is in programming mode), plus a row of blinking icons located immediately above the six Equipment Keys. 2. Press the appropriate Equipment Key (either #S, #P, #1, #2, #3 or #4). The icon above the Equipment Key will stop blinking, the remaining icons will disappear, and the programmed START TIME (blinking) and RUN TIME will be displayed. 3. Press the Cancel Key. The Display will indicate a START TIME (blinking) of 0:00 and a RUN TIME of 0: If you wish to cancel additional program(s), return to Step 2 (i.e. press the appropriate Equipment Key). 5. If you wish to cancel all of the programs, press and hold down the Cancel Key for 5 seconds. After 5 seconds, a continuous alarm will sound (until you release the Cancel Key), indicating that all of the programming has been erased. 29
33 Operating Instructions Lx3000 POWER CENTER Lx3000 Equipment Service Keys Located in close proximity to your pool and spa equipment, the Lx3000 Power Center provides your Pool Serviceperson with manual control of the system without having to gain access to the Cp3000 Controller. Caution: To prevent possible water damage, the door of the Lx3000 must be kept closed at all times. There are no user-serviceable components located behind service panel in the right-side compartment. Do not remove service panel. Refer service to qualified personnel only. Equipment Service Keys and Status Lamps for all of the equipment are located in the left-side compartment. AUTO/SERVICE KEY Pressing this Key will toggle the Control System between Auto and Service modes: Auto: Keep the System in this mode during normal equipment operation. In Auto mode, it will not be possible to manually activate any of the Equipment Service Keys at the Lx
34 Operating Instructions Note: A blinking Auto Status Lamp indicates that the equipment is undergoing a 3-Hour program override. See 3- HOUR FILTER OVERRIDE for details. Service: This mode disables the Cp3000 Controller and provides your Pool Serviceperson with complete manual-override capability, using the various Equipment Service Keys at the Lx3000. Note: Manual-activation of equipment from the Lx3000, will override any of the built-in equipment interlocks and safety delay circuits. EQUIPMENT SERVICE KEYS Key #S: Pressing this Key will manually toggle the Intake and Return Valve Actuators through the following options: Spa: Rotates both Valves to spa circulation. Fill: Rotates Intake Valve to pool suction and Return Valve to spa return positions. Drain: Rotates Intake Valve to spa suction and Return Valve to pool return positions. Note: If there is no Status Lamp, both Valves will rotate to pool circulation. Key #P: Manually activates the filter pump. Key #1: Manually activates equipment connected to Aux1 circuit. Overrides Equipment Key #1 at the Cp3000 Controller. Note: If the system incorporates an automatic pool cleaner, it is controlled by this circuit. Keys #2 - #4: Manually activates equipment connected to Aux2 through Aux4 circuits. Overrides Equipment Keys #2 through #4 at the Cp3000 Controller. Keys #5 - #6: Manually activates equipment connected to Aux5 and Aux6 circuits. Overrides Equipment Keys at Spa-Side Remote. Heater Key: Manually activates the heater (filter pump must also be on). Solar Key: Manually activates the solar valve and/or solar booster pump (if applicable). TEMPERATURE SENSOR STATUS LAMPS If the Control System is not receiving accurate information from a Temperature Sensor, the appropriate Status Lamp will illuminate. Check cable and connections to appropriate Sensor. If necessary, replace Sensor (model TS-5L). 3-HOUR FILTER OVERRIDE It is possible for the Pool Serviceperson to override the daily equipment operating cycles, and manually activate (or deactivate) any piece of equipment for a 3-Hour period. This is particularly useful when adding chemicals to the pool. 31
35 Operating Instructions Note: The Control System must be in Auto mode to enable this feature. To turn the filter pump on, press Key #P (Filter Pump) 2 times quickly. The Auto mode Status Lamp will begin to blink, and the Filter Pump Status Lamp will illuminate for the 3-Hour cycle. To turn the filter pump off, press Key #P (Filter Pump) 3 times quickly. The Auto mode Status Lamp will begin to blink, and the Filter Pump Status Lamp will not be illuminated during the 3-Hour cycle. To cancel this 3-Hour cycle from the Lx3000 Power Center, press Auto/Service Key to Service mode, and then back to Auto mode. VALVE ACTUATORS Your control system is designed to actuate two motorized valves, which automatically rotate between pool and spa circulation whenever the Spa is activated. A motorized valve may also be used to automatically divert the flow of water through your solar panels (if applicable) whenever solar energy is available. These Valve Actuators are also activated by the Spa/Fill/Drain and Solar Equipment Service Keys at the Lx3000 Power Center. Your system may also include additional motorized valves for hydraulic applications, such as a fountain, waterfall, or pool cleaner. SPA-SIDE REMOTE One or more 4-button waterproof Remote Controls may be located at your spa. This will enable you to override the Cp3000 Controller, and manually activate your spa equipment from the convenience of the spa. 32
36 Operating Instructions Your Pool Builder will have connected this Remote to the appropriate circuits, and labeled each push-button to suit your particular application. The Status Lamp (located in the center of the Spa-Side Remote) will illuminate whenever the spa is being circulated. Whenever the spa is being heated, the Status Lamp will blink. SPA-SIDE HEAT BOOST OPTION If your Spa-Side Remote incorporates a HEAT BOOST push-button, it is possible to manually activate the spa heater, and boost the spa temperature for a five minute period after the Control System has turned the spa heater off. This feature can only be activated if the Status Lamp at the Spa-Side Remote is on, and not blinking (i.e. the spa is being circulated and the heater is not on). To activate this feature, press the HEAT BOOST push-button. The Status Lamp will blink (during the 5-minute cycle) to indicate that the spa is being heated. If you wish to turn the heater off at any time during this 5-minute cycle, press the HEAT BOOST push-button. The Status Lamp will stop blinking to indicate that the spa is no longer being heated. DISABLING THE SPA-SIDE REMOTE It is possible to disable the Spa-Side Remote(s) from your Control System. This feature is convenient, if you do not wish children to play with the Spa-Side Remote or you wish to prevent the unauthorized use of your spa while you are away from home. To achieve this, press the Remote Control at Spa Key, which is located behind the right-side door of the Cp3000 Controller. If the status lamp is illuminated, the Remote Control is operational. If the status lamp is not illuminated, the Remote Control is disabled. 33
37 Operating Instructions SYSTEM OPTIONS 2-SPEED FILTER PUMP CONTROL If your system incorporates a 2-Speed Filter Pump, the Cp3000 has been designed to provide you with the maximum energy- efficient usage of this feature. See 2-SPEED FILTER PUMP CONTROL in the Installation section for details. Although your Pool Builder may have adjusted the two speed control circuitry to your specific requirements, the Cp3000 typically switches the pump to high speed under any of the following conditions: 1. For five minutes when the pump is first turned on. This features establishes proper flow through the system, and packs the filter grids. After five minutes, the pump will automatically switch to low speed. 2. Whenever the pool cleaner (if applicable) is running. This provides sufficient flow for the pool cleaner to operate effectively. 3. During spa circulation to increase the jet action. 4. Whenever the heater is on. Larger heaters may require high speed circulation for proper operation. 5. Whenever your solar system (if applicable) is operating. This provides high flow rate through your solar panels, which ensures the most efficient usage of the available solar energy. 6. Whenever a dedicated Equipment Key is pressed. SPA WATERFALL CONTROL If your spa water level is elevated above that of the pool, it is possible to circulate the pool water back to the spa, thus creating an overflow (waterfall effect) from the spa to the pool. This effect will cease during spa circulation or you turn on your booster pump pool cleaner (if applicable). This feature can be activated from Equipment Key #2 (Aux2 circuit) at the Cp3000 Controller. See SPA WATERFALL CONTROL SWITCH for details. FREEZE PROTECTION It is possible to protect the plumbing and equipment from possible freeze damage by activating the filter pump and other pumps whenever the temperature falls to 35 Fahrenheit. Your Pool builder may have already activated this feature. See FREEZE PROTECTION SETTINGS for details. Note: This type of freeze protection will not provide circulation of water through your solar panels. Solar freeze protection must be accomplished by other methods. See Plumbing Requirements for details. 34
38 Maintenance MAINTENANCE CLEANING THE SPA For cleaning or maintenance purposes, it is possible to use the Control System to automatically empty your spa and then to refill with clean water from your pool. At the Lx3000 Power Center: 1. Press Auto/Service Key to switch the system to Service mode. 2. Press Key #S until Drain Status Lamp is illuminated. 3. Press Key #P (Filter Pump) to turn the filter pump on. The spa will begin to drain into the pool. Caution: Do not leave equipment unattended when draining or filling the spa. 4. Before the spa has drained completely, press Key #P (Filter Pump) to turn the filter pump off. The spa will stop draining, and cleaning can now commence. Note: The spa should not be drained completely, or prime will be lost. 5. When cleaning is complete, press Key #S until Fill Status Lamp is illuminated. 6. Press Key #P (Filter Pump) to turn the filter pump on. The spa will begin to fill with clean water from the pool. 7. When the spa water level has returned to normal, press the Auto/Service Key to switch the system back to Auto mode. ADDING CHEMICALS When adding chemicals to the water it is possible to override the daily equipment operation cycles, and activate (or shut-off) the filter pump for a 3-Hour period. See 3-HOUR FILTER OVERRIDE for details. WINTERIZING THE SYSTEM During the winter season, it is possible to disable the pool from your control system, but still be able to use your spa. Consult a qualified service company to winterize your pool and protect the plumbing from freeze damage. The following procedure will disable the pool equipment: 1. At the Lx3000 Power Center, press the Auto/Service Key to switch the system to Service mode, and press Key #S until Spa Status Lamp is illuminated. 2. Flip toggle switch on back of Intake and Return Valve Actuators to OFF. 3. At the Lx3000 Power Center, press Auto/Service Key to return system to Auto mode. 4. At the electrical supply panel, turn off the pool cleaner circuit breaker (if applicable). 5. At the Cp3000 Controller, press the Pool Heat Source Key until Off Status Lamp is illuminated. 6. If your control system incorporates solar, ensure that the panels are completely drained. To inactivate the Solar Temperature Sensor, it is necessary to adjust the FEATURES Program Switch, which is located at top center of Lx3000 circuit board. Use the corner of a small screwdriver or other blunt instrument to slide Switch #1 (SOLAR) to the OFF position. 35
39 Maintenance If recirculating freeze protection has been set on your system, it may not be necessary to winterize the pool. However, it is recommended that the Water Temperature Sensor be calibrated accurately before the onset of the winter season. REPLACING THE BACK-UP BATTERY There is a small 3-Volt lithium battery located inside the Cp3000 Controller. In the absence of power, this battery will keep the clock running and retain the programming in memory for approximately 2 years. The display will be blank during power failure. While power is connected to the system, the battery will not be drained. However, it is not rechargeable. It is recommended that the battery be replaced every 5 years. The replacement battery is available from your pool dealer (Compool model BAT-3), or can be purchased at Radio Shack or your local drug store (Type CR2032, or equivalent). To replace the battery: 1. Do not turn the power off. 2. Open Cp3000 doors and remove the four mounting screws. 3. Close Cp3000 doors and pull enclosure away from wall. 4. Pry-out battery from battery clip, and replace it with a new one. Pay special attention to the polarity (+ sign faces up). 36
40 Problem Solving PROBLEM SOLVING DISPLAY READS Err" 1. At the Lx3000 Power Center, check the Water Temperature Sensor Status lamp. 2. If lamp is illuminated, check cable and connections to Sensor. 3. If necessary, replace Sensor (model TS-5L). INCORRECT TEMPERATURE READING Calibrate temperature sensor. See CALIBRATING TEMPERATURE SENSORS. HEATER DOES NOT OPERATE 1. At the Cp3000 Controller, press Key #S (turn on the spa). 2. Make sure that preset temperature setting for the spa is higher than the current water temperature. 3. At the heater, make sure that the ON-OFF switch is ON position and temperature dial is set to highest setting. CANNOT SELECT SOLAR HEATING At the Lx3000 circuit board, locate FEATURES Program Switch, and make sure that (SOLAR) is in the ON position. SOLAR HEATING NOT ON WHEN IT SHOULD BE 1. At the Cp3000 Controller, make sure that either the pool or spa is being circulated. 2. The Cp3000 system has a 10 Fahrenheit solar differential. This means that if the pool temperature is 80 Fahrenheit, the solar temperature must be 90 Fahrenheit or higher before the solar system is activated. 3. Check calibration of Solar Temperature Sensor. ADJ 2 will indicate the current solar temperature. If temperature display is not correct, then adjust calibration as necessary. EQUIPMENT DOES NOT TURN OFF AT EXPECTED TIME 1. Manual activation of equipment will override any daily operating cycle which may be in effect. If the equipment was turned on manually, it will run for 12 hours and automatically turn off. 2. At Cp3000 Controller, verify that the problem is not program-related. If you see PROG 1 while reviewing programs, then that equipment has more than one program. Press same Equipment Key again to view additional programs. Cancel programs as needed. See Programming for details 3. It is normal for the freeze protection circuitry to turn equipment on when the temperature falls to 35 Fahrenheit. At the Lx3000 circuit board, locate 7-position FREEZ PROT Program Switch, and determine which circuits have been selected for freeze protection. EQUIPMENT TURNS OFF AFTER 12 HOURS 1. This is normal if equipment is turned on manually. A built-in 12 hour shut-off will always turn your equipment off. 2. This function overrides programs that have both a START TIME and a RUN TIME. 37
41 Problem Solving EQUIPMENT TURNS ON AT AN UNEXPECTED TIME 1. At the Cp3000 Controller, verify that the problem is not program-related. If you see PROG 1 while reviewing programs, then that equipment has more than one program. Press same Equipment Key again to view additional programs. Cancel programs as needed. 2. It is normal for the freeze protection circuitry to turn equipment on when the temperature falls to 35 Fahrenheit. At the Lx3000 circuit board, locate 7-position FREEZ PROT Program Switch, and determine which circuits have been selected for freeze protection. SPA-SIDE REMOTE NOT WORKING At the Cp3000 Controller, locate the Remote Control at Spa Key (behind right-side door), and verify that status lamp is on. SPA-SIDE EQUIPMENT TURNS OFF AFTER 30 MINUTES This is a normal function for Aux5 and Aux6 circuits. If you would like to disable this function, adjust the 3-position S1 Program Switch which is located at center right-side of the Cp3000 circuit board (see SPA-SIDE COUNTDOWN TIMER for details). NO DISPLAY AT Cp At the Lx3000 Power Center, verify Auto/Service Status Lamp is illuminated (this confirms there is power to the system). 2. Unplug communication cable from Cp3000 and Lx3000 circuit boards. Temporarily transfer Cp3000 Controller to equipment site, and use 4 test cable (included with system) to interconnect Cp3000 with Lx If the test cable activates the Cp3000 display, repair or replace communication cable. ABNORMAL OPERATION Re-setting the Cp3000: 1. Remove Cp3000 control panel from wall. 2. Disconnect 6-conductor communication cable. 3. Locate resetting pins on lower right hand corner of circuit board. 4. Unplug shorting plug from NORMAL position, and insert into RESET position. 5. Return shorting plug to NORMAL position. 6. Reconnect 6-conductor communication cable. 7. Re-install Cp3000 control panel. This has reset the Cp3000 circuit board. Be sure to reset the Clock Time, Programs, and Sensor Calibration. Re-setting the Lx3000 Turn system power off (momentarily trip system circuit breaker at sub-panel). This will reset the Lx3000 circuit board. 38
42 Warranty WARRANTY Compool Corporation warrants to the purchaser of this electronic control system, for the period of one year from the date of original purchase for use, that any defective product proved to be caused by faulty workmanship or faulty material, will be repaired or replaced at Compool s option at no charge, providing the product is returned to Compool with all transportation charges prepaid. This warranty covers the Cp3000 Controller, Lx3000 Power Center, CVA-24 Valve Actuators, and optional Remote Controls including all components and parts. It extends to the first retail purchaser and any subsequent owners of the system. This limited warranty applies only to controls which have been installed and maintained in strict accordance with installation and operating instructions provided by Compool Corporation, using installation hardware supplied and/or recommended in writing by Compool, and to controls which have been connected to the correct supply voltage. This limited warranty does not apply to any controls which have been repaired or altered by anyone other than Compool or a person authorized by it; or which have been subject to misuse, neglect or accident; or which have been damaged by wind, rain, lightning, freezing or other cause, thing, person, or act of God; or which have been subject to damage in transit, during installation, or by someone other than Compool Corporation; or which have been damaged because of a defect in a component or part which is not part of the Compool Control System; or upon which the serial number or manufacture date has been altered, effaced or removed. This warranty gives you specific legal rights and you may also have other rights which vary from State to State. Compool Corporation does not authorize any person to create any other obligation or liability in connection with Compool controls. Compool Corporation makes no warranty of merchantability or fitness for any use. Any implied warranty applicable to Compool controls is limited in duration to the duration of this written warranty. Unless state law provides otherwise, Compool Corporation shall not be liable for consequential or incidental damages resulting from breach of this written warranty or any implied warranty, or any inconvenience, loss of time, or incidental expenses such as telephone calls. Compool Corporation shall not be liable for any labor charges associated with the removal or reinstallation of any soclaimed defective products. To exercise this warranty, send defective parts*, with copy of dated receipt and a brief description of the problems encountered, postage prepaid, to: COMPOOL CORPORATION 599 Fairchild Drive Mountain View, California For questions, repairs, replacement parts, or information on possible Authorized Service Centers within your vicinity call: Compool Customer Service Monday - Friday 8:00 a.m. - 5:00 P.M. Pacific Standard Time *For your protection, you should always insure your package when shipping or mailing. 39
43 Index INDEX NUMERICS 2-SPEED FILTER PUMP CONTROL 15, 34 3-HOUR FILTER OVERRIDE 31 A ADDING CHEMICALS 35 ADDING RELAYS 7 AUTO/SERVICE KEY 30 AUXILIARY VALVE ACTUATORS 15 B BASIC PROGRAM 27 BATTERY BACK-UP 22 C CALIBRATING TEMPERATURE SENSORS 20 CANCELING PROGRAM(S) 29 CHECKING DESIRED WATER TEMPERATURE SETTING 25 CLEANING THE SPA 35 COUNTDOWN TIMER PROGRAM 28 CP3000 CIRCUIT BOARD 18 CUSTOM CLOCK OPTIONS 18 CVA-24 VALVE ACTUATORS 11 D DAILY EQUIPMENT OPERATING CYCLES 27 DISABLING THE SPA-SIDE REMOTE 33 DISPLAY 23 E EQUIPMENT KEYS 23 EQUIPMENT LOCATION 4 EQUIPMENT POWER 7 EQUIPMENT SERVICE KEYS 31 EQUIPMENT STATUS LAMPS 22 F FAHRENHEIT/CELSIUS TEMPERATURE DISPLAY 25 FREEZE PROTECTION 34 FREEZE PROTECTION SETTINGS 16 G GAS HEATER CONNECTIONS 12 H HEAT SOURCE KEY 24 HEATER PROTECTION 21 HIGH VOLTAGE THERMOSTAT HEATER 16 HIGH VOLTAGE WIRING 5 I IMPORTANT SAFETY INSTRUCTIONS 1 INSTALLATION 2 L LOW VOLTAGE CABLES 9 LOW VOLTAGE WIRING 9 LX3000 CIRCUIT BOARD 9 LX3000 EQUIPMENT SERVICE KEYS 30 LX3000 POWER CENTER 5, 30 M MAINTENANCE 35 MOD-VLV3 15 MOUNTING THE CP3000 CONTROLLER 10 MULTIPLE PROGRAMS 28 O ONCE ONLY PROGRAM 29 OPERATING INSTRUCTIONS 21 OVERRIDING THE SAFETY DELAY CIRCUITS 22 P PLUMBING REQUIREMENTS 3 POOL AND SPA HEATING 24 POOL CLEANER PROTECTION 21 PROBLEM SOLVING 37 PRODUCT PACKAGE 2 PROGRAMMING 27 R REPLACING THE BACK-UP BATTERY 36 REVIEWING THE PROGRAM(S) 29 S SAFETY FEATURES 21 SAFETY NOTICE 1 SETTING DESIRED WATER TEMPERATURE 25 SETTING THE CLOCK 26 SOLAR BOOSTER PUMP CONTROL 17 SOLAR ONLY 25 SOLAR PRIORITY 25 SOLAR TEMPERATURE SENSOR 17 SPA WATERFALL CONTROL 34 SPA WATERFALL CONTROL SWITCH 18 SPA-SIDE COUNTDOWN TIMER 18 SPA-SIDE HEAT BOOST OPTION 33 SPA-SIDE REMOTE 14, 32 SPECIAL TOOLS REQUIRED 2 SUB-PANEL 5 SYSTEM OPTIONS 14, 34 SYSTEM POWER 6 SYSTEM START-UP 19 T TEMPERATURE KEYS 25 TEMPERATURE SENSOR STATUS LAMPS 31 U UNDERWATER LIGHTS 8 USING THE CRIMPING TOOL 11 USING YOUR SPA 24 V VALVE ACTUATORS 32 W WARRANTY 39 WATER TEMPERATURE SENSOR 12 WINTERIZING THE SYSTEM 35 40
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
EasyTouch 8 and 4 Pool and Spa Control System (with optional IntelliChlor Salt Chlorine Generator) Installation Guide
EasyTouch 8 and 4 Pool and Spa Control System (with optional IntelliChlor Salt Chlorine Generator) Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
SOLARTOUCH SOLAR CONTROLLER FOR POOL AND SPA
SOLARTOUCH SOLAR CONTROLLER FOR POOL AND SPA INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Contents Important Warning and Safety Instructions...
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English. 1-800- RAIN BIRD (800-724-6247) or visit www.rainbird.
Rain+Birdt Simple To Set r (SST) Setup & Operation Instructions English Installation...2 Tools and Supplies Needed...2 Step 1. Mount r...2 Step 2. Connect Power...2 Indoor r...2 Outdoor r...2 Step 3. Connect
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
VS CONTROL PACK INSTALLATION INSTRUCTIONS
VS CONTROL PACK INSTALLATION INSTRUCTIONS Hot Tub Works www.hottubworks.com 1-800-770-0292 [email protected] Congratulations! You have purchased and are about to install in your spa, the most
Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.
Install Guide CT100 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
Installation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits 7.5 and 0 TON Package A/C Systems Description Installation of 08/40V and 480V H5HK 3 Phase Heater Kits in 7.5 and 0 TON Packaged Air Conditioners.
with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00
Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
Installation Instructions
Installation Instructions Built-In Dishwasher If you have questions, call 1-800-4-MY-HOME (1-800-469-4663) or visit our website at: www.sears.com BEFORE YOU BEGIN Read these instructions completely and
EasyTouch and IntelliTouch Pool and Spa Control System (with optional IntelliChlor Salt Chlorine Generator) Load Center Installation Guide
EasyTouch and IntelliTouch Pool and Spa Control System (with optional IntelliChlor Salt Chlorine Generator) Load Center Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
HEAT PUMP PROGRAMMABLE THERMOSTAT
HEAT PUMP PROGRAMMABLE THERMOSTAT SA PM 3 COOL TEMP Form 44014-01 r010408 Model 43168 Owners Manual 1 Congratulations! Heat Pump Programmable Thermostat Model 43168 THERMOSTAT CONTROLS Switches & Buttons...15
Install Guide 3M-50. Caution. Caution
PG 1 Install Guide 3M-50 aution Your thermostat is a precise instrument, handle it with care. Turn off electricity to the HVA system before installing or servicing thermostat or any part of the system.
INSTALLATION MANUAL. Installation Instructions
INSTALLATION MANUAL Power-Pole Signature Series Shallow Water Anchor Installation Instructions CAUTION: Read this instruction manual carefully. Become familiar with the controls and know how to operate
Install Guide CT101. Caution. Caution
Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE
LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE Applies to Models: 75W, 150W, 300W, 600W, 900W, 1200W ATTENTION: Please read this guide carefully to ensure safe and efficient
ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10
Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14
AMERBRITE UNDERWATER WHITE LED POOL LAMP
AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2
Remote Faucet Pump System USE &CARE GUIDE See Important Safeguards on page 2 An exclamation point within an equilateral triangle is intended to alert user to the presence of important operating and maintenance
GL-235 Solar Pool Controller
GL-235 Solar Pool Controller Installation & Operation Manual G LDLINE CON TROLS www.goldlinecontrols.com Description The GL-235 is a differential temperature control for solar heating of pools, spas, and
Heat Tracing Sales Mt. Airy, Maryland www.heattracingsales.com 410-795-2223. Installation Instructions
Chromalox Installation Instructions DIVISION 4 SALES REFERENCE DATE SERVICE REFERENCE SECTION DTS (Supersedes PJ944-5) PJ944-6 161-562581-049 MARCH, 2012 DTS-HAZ For Use With Self-Regulating & Constant
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
Operating Manual Color Changing Fountains
Operating Manual Color Changing Fountains 1-877-80-PONDS www.atlanticwatergardens.com Introduction Thank you for purchasing Atlantic s Color Changing Fountains overflowing features that glow from within.
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260
THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260 STANDARD THERMOSTAT KIT 1.0 KIT CONTENTS Parts included: 1 x Thermostat 1 x Wall plate 2 x Mounting box screws 1 x Floor temperature
INSTALLER S & OWNER S MANUAL
INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE
PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS
PT-6000 Power Tower INSTALLATION MANUAL 10.5 9.75 12 22.75 10.75 MAXIMUM SOIL HEIGHT: DO NOT ALLOW FILL TO EXCEED THIS LEVEL! 11.5 4 4 13 Optional PT-BASE for new installations or when previous 2000/6000
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1
Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat
Builder MODEL 1010 Series Non-Programmable Single Stage Heat/Cool Thermostat USER MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
Before installation it is important to know what parts you have and what the capabilities of these parts are.
INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With
Generator Transfer Switch Model # HTS15-AUTO
Generator Transfer Switch Model # HTS15-AUTO Congratulations on your purchase of our Single Circuit Generator Transfer Switch, We hope this meets and exceeds your expectations. If at anytime you have any
WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA
Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set
QT Residential Blower Metal Residential Blower
TROUBLESHOOTING HANDBOOK QT Residential Blower Metal Residential Blower Blower Basics Polaris aboveground, residential blowers are specially designed for installation in noise-sensitive environments. All
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
SunTouch. Installation and User s Guide. Pool, Spa and Solar Control System
SunTouch Pool, Spa and Solar Control System IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation and User s Guide 2011 Pentair Water Pool and Spa, Inc. All
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.
Thermwire Freeze Protection Heating Cable Selection Guide Pipe Freeze Protection Heating Cable Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord & Plug Thermwire-Comp Refrigeration
Installation Instructions
GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover
Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:
Guide for Modified Assembly: Lightning McQueen By: Collin Patterson, University of Delaware Materials and Tools: PVC o 40 inches of 1 in diameter PVC o 25 inches of ¾ in PVC o 4 x 1 in elbows o 2 x ¾ in
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
SOLAR SYSTEMS & PARTS SOLAR SYSTEMS AND PARTS CATALOG. pentairpool.com
SOLAR SYSTEMS & PARTS SOLAR SYSTEMS AND PARTS CATALOG pentairpool.com ENLIST THE GREEN TEAM FOR CUSTOMER CONVENIENCE AND ENERGY SAVINGS The SunTouch and SolarTouch Solar Control Systems are a perfect fit
PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE
Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface
Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
Installer s Guide 18-GJ11D1-2 : Models: BAYUVCLK001-40 Watt, 2 Lamp NOTE: A BAYCC24VK01 can be installed for Series 8 Air Handlers to extend the life of the lamp. This accessory kit will disable the lamp
Not required for most applications Not required for most applications High pressure (12-803 provided) High pressure (12-803 provided)
ELECTRIC FUEL PUMPS P/N 12-801-1, 712-801-1, 12-802-1, 712-802-1, 12-815-1, & 712-815-1 FUEL PRESSURE REGULATORS P/N 12-803, 12-501, 12-804, 12-500, & 15812NOS Installation Instructions THESE INSTRUCTIONS
SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
WHOLESALE DIRECT INC. 5620 WEST 65TH STREET
Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically
Control Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Table of Contents Introduction:...5 Installation:...5
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
430 Power/Electronics Replacement
Replacing the main board WARNING Before proceeding, turn off the main power switch and unplug the power cord. Caution Make sure you are properly grounded with an ESD strap before continuing. The main printed
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:[email protected] www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
GPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles John Deere Sprayers 4720 4630 4730 4830 AutoTrac Ready PN: 602-0227-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions in this manual
TOYOTA TACOMA 2008- HANDS FREE BLU LOGIC Preparation
TOYOTA TACOMA 2008- HANDS FREE BLU LOGIC Preparation Part #: PT923-00112 Conflicts: JBL Audio, Factory Navigation NOTE: Part number of this accessory may not be the same as the part number shown. Kit Contents:
LED MOTION ACTIVATED FLOOD LIGHT
Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español
Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types
Installation Guide VisionPRO TH8000 Series Touch-screen Programmable Thermostat This manual covers the following models TH8110U: For 1 Heat/1 Cool systems TH8320U: For up to 3 Heat/2 Cool systems TH8321U:
TOYOTA Tundra 2007 - BACK-UP CAMERA SYSTEM Preparation
Preparation Part Number(s): PT233-34070, PT923-35070-11, PT923-35070-43 NOTE: Part number of this accessory may not be the same as part number shown. Back Up Monitor Kit Contents PT923-35070-11 / PT923-35070-43
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide
IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide *619751* P/N 619751 - Rev C IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V
Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................
Water Tec of Tucson Water Systems
Water Tec of Tucson Water Systems Water Filter Owner s Manual Water Tec of Tucson www.water-tec.com 4601 S. 3 RD Avenue Tucson, AZ 85714 (520) 790-1512 Fax (520) 745-0549 1 MAIN COMPONENTS Your water treatment
FG MOISTURE MONITOR Installation & Operation Manual
FG MOISTURE MONITOR Installation & Operation Manual Issue 3.0 7/20/10 1 Contents SERVICE AND TECHNICAL SUPPORT... 2 INSTALLATION:... 3 MOISTURE SENSOR INSTALLATION:... 3 SENSOR CONNECTOR:... 5 MONITOR
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH
ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH The original design of the 03 Alpine Coaches (and perhaps other years as well) did not include any kind of engine fan engage mechanism
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Ceiling Fan Installation Instructions
Ceiling Fan Installation Instructions 1525..series OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS Total fan wieght with light kit 1-1525-CUL-English INSTALLATION CH-545 Safety Tips WARNING: TO REDUCE
Table of Contents. www.hunterfan.com. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.
www.hunterfan.com Table of Contents What to Expect with Your Installation 30 inches Hanging the Fan Wiring 8 Maintenance, Operation & Cleaning Light Kit 13??? 14 1 9 Troubleshooting 11 5 Blades Motor Housing
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables
Installation Instructions DTS-HAZ DTS-HAZ-DC for Use with Self-Regulating & Constant Wattage Heating Cables PJ944-9 5625-81049 May 2013 1 2 DTS-HAZ Self-Regulating & Constant Wattage Heating Cables Junction
Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7
THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L
An ISO 9001:2008 Registered Company ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L Introduction The ILISC515-A is a microprocessor driven system for controlling wheelchair
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system
MODELS 8007 Gorilla Cycle Alarm 8017 Gorilla Cycle Alarm with 2-way pager system 1018 2-way pager system Remote Control Motorcycle Alarm System Installation & Operation Instructions Sistema de Alarma de
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of