HOT WATER SYSTEMS.

Size: px
Start display at page:

Download "HOT WATER SYSTEMS. www.thermann.com.au"

Transcription

1 HOT WTER SYSTEMS

2 GS STORGE HOT WTER SYSTEM THE THERMNN 4* GS HOT WTER HETER CN SUIT NY FMILY TYPE. WITH N DJUSTLE THERMOSTT FOR SFETY ND EFFICIENCY IT LLOWS YOU TO E IN CONTROL OF YOUR OPERTING COSTS ND 422 PERFORMNCE. THE UNIT HS SMLL FOOTPRINT 162 WHICH MKES IT IDEL FOR REPLCING 502 3* CHNGEOVER. GS INLET D C 502 (219) 477 SPECIFICTIONS Gas Tank Measurements 135L 170L Capacity (litres) L 170L No. People Net Weight Empty (kg) Relief Valve Pressure (kp) Gas Consumption (MJ/h) 135NG = NG = LPG = 22.5 Recovery 45 o C rise (L/hr) First Hr Delivery Dimensions (mm) 135L 170L Height () Hot Water Outlet () Cold Water Inlet (C) Gas Inlet (D) Water Inlet/Outlet 7YER Cylinder C 1YER Parts and labour 2

3 ELECTRIC LRGE HOT WTER SYSTEM THERMNN ELECTRIC STORGE HOT WTER UNITS RE N INSULTED STORGE VESSEL EFFICIENTLY STORING HOT WTER, REDY FOR USE, WHEN YOU NEED IT. THE THERMNN RNGE OF ELECTRIC WTER HETERS OFFER SOLUTIONS IN EIGHT DIFFERENT SIZES TO SUIT YOUR NEEDS. 25 K 25 K C C SPECIFICTIONS Electric Tank o Measurements 80L 125L 160L 250L 315L 400L D D E E 80L 125L 160L Total Height () Total Diameter () Outlet Height (C) Inlet Height (D) Electrical Entry (E) Element ngle (K) 55 o 55 o 55 o 72 o 72 o 72 o Storage Capacity Hot Water Delivery Net Weight Empty Element Sizes (kw) , , Relief Valve Pressure (kpa) Max Inlet Pressure Inlet/Outlet No. People (continuous) No. People (off peak) Inlet/Outlet No. People (continuous) No. People (off peak) L 315L 400L Without an ECV (kpa) With an ECV (kpa) YER Cylinder 1YER Parts and labour 3

4 ELECTRIC SMLL HOT WTER SYSTEM THERMNN SMLL ELECTRIC STORGE HOT WTER UNITS LLOW YOU TO INSTLL HOT WTER WHERE SPCE ND CCESS IS RESTRICTIVE. WITH ITS V FIT CONFIGURTION, INLETS ND OUTLETS RE CONFIGURED FOR ESE OF INSTLLTION. VILLE IN PPLINCE WHITE FOR MORE ESTHETICLLY PLESING UNIT. SPECIFICTIONS Electric Tank Measurements 25L 50L 25L 50L Total Height () Total Diameter () Outlet Height (C) Inlet Height (D) Electrical Entry (E) Element ngle (K) Storage Capacity (litres) Hot Water Delivery (litres) Net Weight Empty (kg) Inlet/Outlet No. People (continuous) No. People (off peak) 7YER 1YER Element Size (kw) 2.4*, *, 3.6 Relief Valve Pressure (kpa) Max Inlet Pressure Without an ECV (kpa) With an ECV (kpa) Cylinder Parts and labour *2.4kW plug in only 4

5 CONTINUOUS FLOW 5* HOT WTER SYSTEMS THE THERMNN 5* GS CONTINUOUS FLOW SYSTEM HETS WTER S IT FLOWS THROUGH COILED PIPE ROUND GS URNER, WHICH MENS YOU LL NEVER RUN OUT OF HOT WTER Recess ox Painted SPECIFICTIONS CLE CLE ENTRY POINT ENTRY POINT HOT HOT WTER WTER OUTLET OUTLET R1/2 / COLD WTER COLD INLET R1/2 /15 WTER INLET WTER INLET FILTER INLET FILTER GS GS SUPPLY INLET INLET PRESSURE RELIEF VLVE RELIEF VLVE Kitchen Controller athroom/ensuite Controller Continuous Flow 5* Measurements 16L 20L 26L Nominal hourly gas consumption (MJ/h) Test point pressure NG (kpa) Test point pressure LPG (kpa) Minimum water pressure (kpa) CLE ENTRY POINT Maximum water pressure (kpa) HOT WTER OUTLET Minimum gas inlet pressure (kpa) NG 1.13 LPG 2.75 NG 1.13 LPG 2.75 NG 1.13 LPG 2.75 Maximum gas inlet pressure (kpa) NG 5.0 LPG 7.0 NG 5.0 LPG NG 5.0 LPG 7.0 Minimum Flow Rate Ignition (l/min) Input voltage single phase 50Hz (v) ccessories 585 Code Kitchen controller with 15m cable athroom controller with 15m cable Ensuite controller with 15m cable Recess ox Gal COLD WTER INLET Recess ox Painted WTER INLET FILTER Locking GS racket SUPPLY INLET PRESSURE RELIEF VLVE 16L 20L 26L No. athrooms Energy Rating (Stars) Maximum output current () Inlet gas connection male thread R3/4" (20mm) R3/4 (20mm) R3/4 (20mm) Cold water connection male thread R1/2" (15mm) R1/2" (15mm) R3/4" (20mm) Hot water connection male thread R1/2" (15mm) R1/2" (15mm) R3/4" (20mm) 25 rise (L/min) 40 rise (L/min) 16L 20L 26L Gas Type vailable NG, LPG NG, LPG NG, LPG Relief valve pressure setting (kpa) Weight dry (kg) Dimensions (HxWxDmm) 575x350x x350x x350x YER 3YER SIG pproval certificate no. GSCS Watermark Certificate of compliance WMK Heat Exchanger Parts and labour 5

6 CONTINUOUS FLOW 6* HOT WTER SYSTEMS THE THERMNN 6*, ENERGY EFFICIENT GS CONTINUOUS FLOW UNIT ENSURES YOU WILL HVE ENOUGH HOT WTER, WHEN YOU NEED IT. WITH 12 YER WRRNTY, YOU CN REST SSURED YOU RE COVERED FOR THE LIFE OF THE UNIT, ND UNIVERSL CONTROLLERS ENSURE YOU LWYS HVE PRECISE CONTROL OF YOUR HOT WTER TEMPERTURE SETTINGS. 584mm 39mm 520mm 25mm 68mm 68mm 584mm 39mm 520mm 25mm 350mm 12mm 68mm350mm 68mm 68mm 68mm 68mm 68mm 200mm 12mm 15mm 200mm 546mm 12mm 15mm 546mm 12mm Recess ox Painted SPECIFICTIONS Continuous Flow 6* COLD WTER INLET POWER CLE ENTRY POWER CLE ENTRY PRESSURE RELIEF VLVE HOT WTER OUTLET HOT WTER OUTLET PRESSURE RELIEF VLVE COLD WTER INLET 334mm 100mm 80mm 69mm 46mm REMOTE CONTROLLER CLE ENTRY REMOTE CONTROLLER WTER INLET FILTERCLE ENTRY 174mm 260mm 334mm WTER INLET FILTER GS SUPPLY INLET GS SUPPLY INLET Universal Controller Measurements 16L 20L 26L ccessories Code Nominal hourly gas consumption by proportional electronic gas control (MJ/h) Test point pressure (Natural Gas) (kpa) Test point pressure (Propane) (kpa) Minimum water pressure (kpa) Maximum water pressure (kpa) Minimum gas inlet pressure (kpa) NG 1.13 LPG 2.75 Maximum gas inlet pressure (kpa) NG 5.0 LPG 7.0 NG 1.13 LPG 2.75 NG 5.0 LPG 7.0 NG 1.13 LPG 2.75 NG 5.0 LPG 7.0 Minimum Flow Rate Ignition (l/min) Input voltage single phase 50Hz (V) Maximum output current () Inlet gas connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Cold water connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Hot water connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Relief valve pressure setting (kpa) Weight dry (kg) Dimensions (HxWxDmm) 520x350x x350x x350x200 SIG pproval certificate no. GSCS Watermark Certificate of compliance WMK Universal controller with 15m cable * Recess ox Painted * Recess ox Gal * Locking racket * Flue Diverter L 20L 26L No. athrooms Energy Rating (Stars) (50 C) Energy Rating (Stars) (60 C) 25 rise (L/min) 40 rise (L/min) L 20L 26L Gas Type vailable NG, LPG NG, LPG NG, LPG 12 YER 3YER 6 Heat Exchanger Parts and labour

7 EVCUTED TUE SOLR ELECTRIC OOSTED THERMNN EVCUTED TUE SOLR ELECTRIC OOSTED SYSTEMS HRNESS THE SUN S ENERGY TO HET YOUR WTER. N ELECTRIC ELEMENT IN THE TNK PROVIDES CK UP IF NEEDED, ENSURING PECE OF MIND, WHILST LSO REDUCING YOUR RUNNING COSTS. HW Outlet PTRV Top Sensor ottom Sensor Solar Return Flow Inlet SPECIFICTIONS Electric oosted Tank Measurements (mm) 250L OT 250L MID 315L OT 315L MID 400L OT 400L MID 250L 315L 400L Tank Diameter () Tank Height () HW Outlet PTRV Port No. People No. Tubes *Other kit configurations available Top Sensor Port Solar Return Port ottom Sensor YER 10 YER 1YER Solar Flow Tubes Tank Parts and Labour Cold Water Inlet Dry Weight (kg) Roof Collector Measurements (mm) Dry Weight Collector Width () Length () WO/Tubes W/Tubes 22 Tubes kg 85kg 30 Tubes kg 112kg Dry weights based on 3 track flush mount frame. 7

8 EVCUTED TUE SOLR GS OOSTED THERMNN EVCUTED TUE SOLR GS OOSTED SYSTEMS OFFER RELIILITY ND EFFICIENCY. PSSIVE SUN TRCKING MENS MORE OF THE SUN S RYS RE CONVERTED TO USLE HOT WTER THROUGHOUT THE DY - REDUCING YOUR POWER ILLS. WITH THE GS OOSTED CONTINUOUS FLOW UNIT, YOU LL NEVER RUN OUT OF HOT WTER, NO MTTER THE WETHER. HW Outlet PTRV Top Sensor Solar Return ottom Sensor Flow Inlet SPECIFICTIONS Gas oosted Tank Measurements (mm) 160L GS 250L GS 315L GS 400L GS Tank Diameter () Tank Height () HW Outlet PTRV Port L 250L 315L 400L No. People No. Tubes Gas ooster 26L 26L 26L 26L Top Sensor Port Solar Return Port ottom Sensor YER 10 YER 1YER Solar Flow Cold Water Inlet Tubes Tank Parts and Labour Dry Weight (kg) For 26L Gas Continuous Flow specifications and warranty information refer to page 5. Roof Collector Measurements (mm) Dry Weight Collector Width () Length () WO/Tubes W/Tubes 22 Tubes kg 85kg 30 Tubes kg 112kg Dry weights based on 3 track flush mount frame. 8

9 EVCUTED TUE SOLR HOW IT WORKS ur rises to top STEP 1 The sunlight strikes the dark absorber coating inside the tube. STEP 2 The heat pipe transfers the heat up to the copper header pipe location in the insulated manifold box. STEP 3 circulator moves water from the storage tank bsorber to the Coating copper pipe warming the water. The solar heated water is then pushed down into the storage tank for use. nti-frost is built in to the Thermann system to ensure solar hot water can be provided even in cold regions. ondensed liquid returns to bottom Vacuum Space Heat Transfer Evacuated tube absorbs sunlight and converts to usable heat Vapour rises to top Heat Transfer Condensed liquid returns to bottom bsorber Coating Vacuum Space PSSIVE SUN TRCKING The round tube design of the system passively tracks the sun throughout the day giving the highest possible performance from early morning through to late afternoon. fternoon Midday Morning ELECTRIC & GS SETUPS Electric ooster Gas ooster Thermann Solar Collector Thermann Solar Collector Thermann Solar Collector Solar Flow Solar Flow Pump Station Pump Station Solar Return Solar Return Storage Tank Storage Tank Hot water to house Hot water to house Solar Flow Pump Station Solar Return Storage Tank Gas ooster Hot water to house Cold Inlet Cold Inlet Cold Inlet Note: Diagram not to scale - basic system overview (not installation guide). Note: Diagram not to scale - basic system overview (not installation guide). Note: Diagram not to scale - basic system overview (not installation guide). 9

10 HET PUMP HOT WTER SYSTEM MDE IN GERMNY, THE THERMNN HET PUMP EXTRCTS HET FROM MIENT IR ND QUIETLY TRNSFERS IT TO HET WTER. IT COMES WITH REMOVLE INTKE GRILL FOR ESY CLENING ND SERVICING WHERE CCESS IS LIMITED SPECIFICTIONS Heat Pump Heat output kw Dimensions Heat output at 15/W Capacity (litres) 300 Power consumption kw Relief valve pressure (kpa) 700 Consumption at 15/W Expansion control valve setting* (kpa) 550 Sound data d() Max Supply Pressure - without an ECV (kpa) 500 Sound pressure level at 1m distance in a free field 56 Max Supply Pressure - with an ECV (kpa) 420 Energy data kwh Minimum water pressure (kpa) 200 Standby energy consumption/24h at 65 C (ir 15 C) 1.14 Dimensions mm Electrical details Fuses Rated voltage Phases Frequency Rated current Max. power consumption * ECV not supplied C V 1/N/PE 50Hz W Height of unit when tilted 1990 Height (adjustable feet) Diameter 670 Weights kg Weight (dry) 125 Weight (wet) 428 Connections mm Condensate drain 20 Water connection RP3/4" (20mm) Values 5YER 2YER ir flow rate 550 m3/h 10 Cylinder Parts and labour Lower air temperature limit 0 C Upper air temperature limit 42 C

11 HET PUMP HOT WTER SYSTEM HOW IT WORKS IR OUT IR IN (THERML ENERGY) HOT WTER OUTLET 3 COLD WTER INLET 1. fan draws air through an evaporator. Thermal energy within the air is transferred to a liquid refrigerant causing it to change into a gas. 2. The refrigerant gas is then drawn into a compressor which increases the pressure and as a result increases the temperature. 3. condenser (heat exchanger) then transports the hot gas refrigerant around the outside of the water tank. This heats the water inside the tank and the gaseous refrigerant reverts into a liquid. 4. The pressure of the refrigerant is reduced as it goes through an expansion valve and returns to the evaporator for the process to start again. 11

12 Reece. Works for you. Call or visit for your nearest Reece store. Due to limitations in the printing process the colours in this brochure are a guide only. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. The manufacturer/distributor takes no responsibility for printing errors. ll products enjoy a product replacement warranty. For full warranty details visit V8 [ROCHURE CODE ]

HOT WATER SYSTEMS. www.thermann.com.au

HOT WATER SYSTEMS. www.thermann.com.au HOT WTER SYSTEMS www.thermann.com.au GS HOT WTER SYSTEM The Thermann 4 star Gas hot water heater can suit almost any family type. With an adjustable thermostat for safety and efficiency it allows you to

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

RHEEM DOMESTIC HOT WATER

RHEEM DOMESTIC HOT WATER RHEEM DOMESTIC HOT WTER GS SOLR ELECTRIC WTER SVING USTRLI S FVOURITE NME IN HOT WTER COMES ON STEDY, HOT ND STRONG INSTLL CONTENTS CONTENTS TS 4. Rheem Solar Hot Water 6. Rheem Heat Pump Hot Water 8.

More information

Commercial Hot Water. Make a difference...

Commercial Hot Water. Make a difference... Commercial Hot Water Make a difference... heat S O L A R pumps The Company Quantum Energy Technologies The Quantum story is based on innovation and the quest to harness renewable energy to produce sustainable

More information

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency

More information

Hot Water Decisions Guide

Hot Water Decisions Guide Hot Water Decisions Guide Visit www.reece.com.au/hotwater for our interactive hot water decisions tool. 1 Hot Water Decisions Guide Contents The importance of Hot Water Units Page 3 What are my options?

More information

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60 GAS CONTINUOUS FLOW WATER HEATERS INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60 2 INSTALLATION INSTRUCTIONS IMPORTANT SAFETY

More information

Endless Hot Water 24/7

Endless Hot Water 24/7 Endless Hot Water 24/7 Chromagen Continuous Flow Gas Water Heaters Live in eternal comfort with endless, efficient hot water from Eternity Get hot water on demand with an Eternity continuous flow gas water

More information

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

Solar hot water systems that give energy efficiency a whole new meaning

Solar hot water systems that give energy efficiency a whole new meaning Solar hot water systems that give energy efficiency a whole new meaning The power to cut your energy bills for years to come When it comes to clean, cost effective energy solutions, the Leda Solar Hot

More information

CB29M Bulletin #490071 February 1996

CB29M Bulletin #490071 February 1996 ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

CHAPTER 9: WATER HEATING

CHAPTER 9: WATER HEATING Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors Dr. Nguyen Nguyen An, HUST CONTENTS Energy consumption to produce hot water in residential

More information

How to choose a heat pump and use it wisely

How to choose a heat pump and use it wisely How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hot Water. Heat pump water heaters. Residential and Commercial R410a Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

SunMaxx Solar Filling Station Operating Instructions

SunMaxx Solar Filling Station Operating Instructions SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009 Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

CONTINUOUS FLOW HOT WATER

CONTINUOUS FLOW HOT WATER CONTINUOUS FLOW HOT WATER THE RINNAI INFINITY STORY SO FAR... In the early 2004 s Rinnai launched the first fully electronic gas continuous flow hot water system in Malaysia. Appropriately named the Rinnai

More information

Itho Products for Hot and Boiling water. product-

Itho Products for Hot and Boiling water. product- Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

UNDERSTANDING CENTRAL HEATING SYSTEMS

UNDERSTANDING CENTRAL HEATING SYSTEMS UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,

More information

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar Unvented Direct and Indirect Cylinders Range Tribune HE Solar cylinders have been designed specifically with Solar applications in mind and are based on the highly successful Range

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

Hot Water South Australia

Hot Water South Australia Hot Water South Australia The Offer Hot Water Solutions Offered in - Natural Gas - Electric - LPG Full Product Range in - Traditional Tank - Instantaneous - Heat Pump - Solar Other Services Include - Delivery

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Solar Hot Water. What systems are available?

Solar Hot Water. What systems are available? Solar Hot Water Using the sun s energy to heat water will save you energy, lower your hot water bills, and reduce greenhouse pollution. Solar hot water systems work effectively in Victoria using mature

More information

SunMor SM-V30 Solar Water Heater Installation Manual

SunMor SM-V30 Solar Water Heater Installation Manual SunMor SM-V30 Solar Water Heater Installation Manual Rev. 1.02 Congratulations on the purchase of your new SunMor SM-V30 from Nature s Comfort LLC! You must read this entire instruction manual before beginning

More information

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation) PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold

More information

maximise the sun s energy with warmflow solar Warmflow Solar

maximise the sun s energy with warmflow solar Warmflow Solar maximise the sun s energy with warmflow solar Warmflow Solar Warmflow Solar warmflow solar - the perfect choice Warmflow has been established as a privately owned company since 1970. During this time we

More information

SOLAR HEATING SYSTEMS. www.orkli.com

SOLAR HEATING SYSTEMS. www.orkli.com SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System GTS Gas-to-Steam Humidification System PR0DUCT CATALOG New! Vapor-logic 4 controller with: and LonTalk Plus: New models GTS-500 and GTS-700 Gas has lowest energy operating costs The industry s first and

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

SOLAR HOT WATER SOLUTIONS stainless steel roof systems SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration About Daikin Forward thinking... Daikin has a worldwide

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

AdSORPTION CHILLER NAK

AdSORPTION CHILLER NAK AdSORPTION CHILLER NAK Chilling Capacity from 50 to 430 kw Usage of Surplus Heat from 50 C Ã*%8ÃPE+Ã TECHNICAL DESCRIPTION ADSORPTION CHILLER NAK 1 INTRODUCTION... 2 2 THE PRINCIPLE OF ADSORPTION... 2

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

Air Source Heat Pump Installation and Maintenance Manual

Air Source Heat Pump Installation and Maintenance Manual Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install

More information

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Ergo-Pro Single Line Solar Station Installation and Operating Instructions Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating

More information

SOLAR HOT WATER SOLUTIONS Ground Systems

SOLAR HOT WATER SOLUTIONS Ground Systems SOLAR HOT WATER SOLUTIONS Ground Systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a part of the fabric

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K The Die competent Kompetenzmarke brand for für energy Energiesparsysteme saving systems Conventional gas fired boilers open vented / sealed unvented CGU-2 / CGU-2K CGG-2 / CGG-2K NEW The next generation

More information

THERMOSYPHON HOT WATER SYSTEM IN THE FIJI ISLANDS. We are located about 3000KM South west of Australia and in the middle of the Pacific ocean!

THERMOSYPHON HOT WATER SYSTEM IN THE FIJI ISLANDS. We are located about 3000KM South west of Australia and in the middle of the Pacific ocean! THERMOSYPHON HOT WATER SYSTEM IN THE FIJI ISLANDS BY PHILIP LEE Greetings from the Beautiful Tropical Island of Fiji. We are located about 3000KM South west of Australia and in the middle of the Pacific

More information

Split units TH with hermetic compressors

Split units TH with hermetic compressors Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split

More information

Power consumption (kw)

Power consumption (kw) OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components

More information

Refrigeration Basics 101. By: Eric Nelson

Refrigeration Basics 101. By: Eric Nelson Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs

More information

www.inspection-for-industry.com

www.inspection-for-industry.com Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

Delivering exceptional performance and Ecovalue. Ecocent

Delivering exceptional performance and Ecovalue. Ecocent 1 Delivering exceptional performance and Ecovalue. Ecocent 2 The Ecocent Hot Water System As the cost of providing heating and hot water continues to increase, homes and businesses are seeking out more

More information

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling Water Fired Chiller/Chiller-Heater WFC-S Series: 1, 2 and 3 RT Cooling W E A R E F R I E N D L Y T O T H E E A R T H Water Fired SINGLE-EFFECT Chiller or Chiller-Heater Absorption Principle Cooling Cycle

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger

USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER. Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger Installer / Service Provider details USER MANUAL INSTALLATION INSTRUCTION WARRANTY REGISTER Free Hot Water Solar Storage Tank (SST) with Single/Double coil heat exchanger Customer / User Congratulations

More information

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series

TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series The range of E-Pro cold units includes various types of refrigerated units and worktops. Thanks to the flexible

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Recharge Procedure for Telemark TVP-2000 and TVP-3500 Recharge Procedure for Telemark TVP-2000 and TVP-3500 Required items: 1.) Refrigeration service manifold. 2.) Charge recovery system. 3.) Dry nitrogen gas. If a high pressure cylinder is used, a pressure

More information

MovinCool Office Pro Series. The Portable Spot Cooling Solution

MovinCool Office Pro Series. The Portable Spot Cooling Solution MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment

More information

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

Technical & Specification Information Bosch 32 Series Water Heaters. Bosch Commercial Series Condensing & Non-Condensing Continuous Flow Water Heaters

Technical & Specification Information Bosch 32 Series Water Heaters. Bosch Commercial Series Condensing & Non-Condensing Continuous Flow Water Heaters Technical & Specification Information Bosch 32 Series Water Heaters Bosch Commercial Series Condensing & Non-Condensing Continuous Flow Water Heaters 2 Technical & Specification Information Bosch 32 Series

More information

Solar Hot Water System Operation Manual

Solar Hot Water System Operation Manual Solar Hot Water System Operation Manual Table of Contents 1. Consumer Information 2 1.1. Understanding Water Heating 2 1.2. Solar Water Heating 3 1.3. How Does Boosting Work 5 1.4. Understanding Water

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Element D Services Plumbing

Element D Services Plumbing Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.

More information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting

More information

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5

More information

Air conditioners Heating & Cooling

Air conditioners Heating & Cooling Air conditioners Heating & Cooling Replacement VRV Cost effective upgrade for R-22 s High efficiency Possibility to increase capacity Limited and planned downtime Limited and phased investment cost www.daikin.eu

More information

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety

More information

Solar Thermal Systems

Solar Thermal Systems Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann

More information