Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array
|
|
|
- Violet Byrd
- 9 years ago
- Views:
Transcription
1 November 2015 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report Supporting Network OS and 4.1.2
2 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, HyperEdge, ICX, MLX, MyBrocade, OpenScript, The Effortless Network, VCS, VDX, Vplane, and Vyatta are registered trademarks, and Fabric Vision and vadx are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of others. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade s the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it. The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit
3 Contents Preface... 4 Overview... 4 Purpose of This Document...4 Audience... 4 Objectives... 5 Document History...5 Related Documents...5 About Brocade... 5 About NetApp...6 Configure DUT and Test Equipment...7 Task 1. Brocade VDX Switch Configuration Logical Chassis Mode...7 Task 2. NetApp 3170 Configuration... 7 Task 3. Windows Host Configuration Task 4. Red Hat Linux Host Configuration...26 Task 5. Medusa I/O Generation Configuration...26 NOS Test Report Test Plan Scope Test Configuration...29 DUT Descriptions DUT Specifications...31 DUT Configuration Test Cases Base Functionality Advanced Functionality Stress and Error Recovery Brocade Network Advisor...45 Test Conclusions...46 NOS Test Report Test Plan Scope Test Configuration...48 DUT Descriptions DUT Specifications...50 DUT Configuration Test Cases Ethernet Storage - Base Functionality Ethernet Storage - Advanced Functionality Stress and Error Recovery...85 Test Conclusions...93 Full Network Operating System Configuration Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 3
4 Preface Preface Overview... 4 Purpose of This Document...4 Audience... 4 Objectives... 5 Document History...5 Related Documents...5 About Brocade... 5 About NetApp...6 Overview Many data centers use network attached storage (NAS) for a variety of applications and workloads. As more data is stored on NAS, efficient network designs are under evaluation to minimize latency, to maximize use of interswitch links between switches, and to automate network configuration changes. For these reasons, Brocade VCS Fabric technology with Brocade VDX switches is increasingly being deployed when new NAS arrays are added to the storage pool. Purpose of This Document The goal of this document is to validate Brocade VCS Fabric technology with the NetApp 3170 NAS storage array. The testing includes cases that demonstrate VCS Fabric feature support, high availability and resiliency, and automatic network reconfiguration when links are added or removed. This document provides validation test results for typical use cases of NAS with Brocade VCS Fabric technology and NetApp 3170 NAS storage arrays. Audience This document is written for a technical audience, including solution architects, system engineers, and technical development representatives. 4 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
5 Objectives Objectives 1. Validate interoperability with redundant and nonredundant network topologies with Brocade VCS Fabric technology and the NetApp Identify any unique configuration details necessary to establish end-to-end connectivity. 3. Simulate real-world customer environment perturbation and validate end-to-end behavior and recovery. Document History Date Part Number Description June Initial Release November 2015 Additional Test Configuration and Test Case details added. Related Documents Brocade Network OS Administrator's Guide, v6.0.1 Brocade Network OS Administrator's Guide, v4.1.1 NetApp FAS3170 Documentation Index NetApp Data ONTAP 8, R8.2 7-Mode Documentation Index QLogic 8100 Series Converged Network Adapter User's Guide About Brocade Brocade networking solutions empower the world's leading organizations to transition smoothly to a world where applications and information reside anywhere. This vision is realized through the Brocade One strategy, which is designed to deliver key business benefits such as unmatched simplicity, nonstop networking, application optimization, and investment protection. Innovative Ethernet and storage networking solutions for data center, campus, and service provider networks help reduce complexity and cost while enabling virtualization and cloud computing to increase business agility. To help ensure a complete solution, Brocade partners with world-class IT companies and provides comprehensive education, support, and professional services offerings. To learn more, visit ( Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 5
6 About NetApp About NetApp NetApp creates innovative products-storage systems and software that help customers around the world store, manage, protect, and retain one of their most precious corporate assets: their data. We are recognized throughout the industry for continually pushing the limits of today's technology so that our customers never have to choose between saving money and acquiring the capabilities they need to be successful. 6 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
7 Configure DUT and Test Equipment Task 1. Brocade VDX Switch Configuration Logical Chassis Mode...7 Task 2. NetApp 3170 Configuration... 7 Task 3. Windows Host Configuration Task 4. Red Hat Linux Host Configuration...26 Task 5. Medusa I/O Generation Configuration...26 This section describes the initial configuration of devices under test (DUTs)and test equipment. In some test cases, additional configuration changes are made. Task 1. Brocade VDX Switch Configuration Logical Chassis Mode On the VCS cluster, configure VLAN interfaces on all cluster members. Configure the VLAG interfaces connecting to Windows and Red Hat hosts as well as the NetApp 3170 storage array. NOTE Please see DUT Configuration section of each test report below for applicable configuration commands. Task 2. NetApp 3170 Configuration This section describes the NetApp 3170 NAS and share configurations. 1. Physical Interface Configuration a. For single interface configuration, open the NetApp OnCommand System Manager and navigate to Configuration -> Network -> Network Interfaces. Select the desired physical interface and click Edit. Enter the desired interface IP address in the IPv4 Address / Netmask field. Finally, click Save and Close. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 7
8 Configure DUT and Test Equipment FIGURE 1 NetApp 3170 Network Interface Configuration - Screen 1 8 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
9 Configure DUT and Test Equipment FIGURE 2 NetApp 3170 Network Interface Configuration - Screen 2 b. For LACP interface configuration, open the NetApp OnCommand System Manager and navigate to Configuration -> Network -> Network Interfaces. Then, click on Create VIF to start the VIF Wizard. Supply a name for the Virtual Interface (VIF) Name, select the desired physical interfaces to aggregate, and select LACP as the Trunk Mode. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 9
10 Configure DUT and Test Equipment FIGURE 3 NetApp 3170 VIF Wizard - Screen 1 c. Choose IP based for the Load balancing type. 10 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
11 Configure DUT and Test Equipment FIGURE 4 NetApp 3170 VIF Wizard - Screen 2 d. Choose This interface will not be part of another virtual interface. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 11
12 Configure DUT and Test Equipment e. FIGURE 5 NetApp 3170 VIF Wizard - Screen 3 f. Enter the desired interface IP address in the IPv4 Address / Netmask field. 12 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
13 Configure DUT and Test Equipment FIGURE 6 NetApp 3170 VIF Wizard - Screen 4 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 13
14 Configure DUT and Test Equipment FIGURE 7 NetApp 3170 VIF Wizard - Screen 5 2. Storage Volume Configuration a. Open the NetApp OnCommand System Manager and navigate to Storage -> Volumes. Then, click on Create to start the Create Volume Wizard. Supply a volume name for the Name, select the volume size for Total Size, and set Snapshot Reserve to Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
15 Configure DUT and Test Equipment FIGURE 8 NetApp 3170 Storage Volume Configuration - Screen 1 b. (Optional) After the volume is created, return to Storage -> Volumes, highlight the newly-created volume, and click Snapshot Copies -> Configure. Then, uncheck Make Snapshot directory (.snapshot) visible and uncheck Enable scheduled Snapshot Copies. This option reduces disk usage at the expense of data backup. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 15
16 Configure DUT and Test Equipment FIGURE 9 NetApp 3170 Storage Volume Configuration - Screen 2 16 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
17 Configure DUT and Test Equipment FIGURE 10 NetApp 3170 Storage Volume Configuration - Screen 3 3. CIFS Share Configuration a. Open the NetApp OnCommand System Manager and navigate to Storage -> Shares. Then, click on Create to create a new share. Next, click on Browse and select the full path to the desired volume previously created. The Selected Path will autofill with the appropriate path. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 17
18 Configure DUT and Test Equipment FIGURE 11 NetApp 3170 CIFS Share Configuration - Screen 1 b. Click Create to complete the share creation. FIGURE 12 NetApp 3170 CIFS Share Configuration - Screen 2 18 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
19 Configure DUT and Test Equipment FIGURE 13 NetApp 3170 CIFS Share Configuration - Screen 3 4. NFS Export Configuration NetApp 3170 automatically creates NFS exports for any volumes created, so the exports designated for the Windows servers can be deleted if desired. Open the NetApp OnCommand System Manager and navigate to Storage -> Exports. Then, click on the NFS export you wish to delete and click Delete. For this configuration, anonymous access should be granted to all hosts. Open the NetApp OnCommand System Manager and navigate to Storage -> Exports. Then, click on the NFS export you wish to delete and click on the Unix folder entry and click Edit. Within the Edit Export Rule window, select Grant root access to all hosts under the Anonymous Access header. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 19
20 Task 3. Windows Host Configuration FIGURE 14 NetApp 3170 NFS Export Configuration Task 3. Windows Host Configuration Configuring and mapping windows hosts for the VCS cluster. 1. Configure Windows 2012 Server Hosts for Ethernet Teaming. a. Configure Windows 2012 Server NIC teaming interface for connectivity to VCS cluster. 20 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
21 Configure DUT and Test Equipment FIGURE 15 Windows 2012 NIC Teaming 2. Configure Windows 2008 Server Hosts for Ethernet Teaming a. Configure Windows 2008 Server NIC teaming interface for connectivity to VCS cluster using the Brocade Host Connectivity Manager. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 21
22 Configure DUT and Test Equipment FIGURE 16 Windows 2008 NIC Team using Brocade Host Connectivity Manager 3. Map NetApp 3170 Network Shares on Windows 2012 Server a. Map network drives on Windows 2012 Server hosts. 22 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
23 Configure DUT and Test Equipment FIGURE 17 Windows 2012 NIC Team Configuration - Screen 1 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 23
24 Configure DUT and Test Equipment FIGURE 18 Windows 2012 NIC Team Configuration - Screen 2 4. Map Network Drives on Windows 2008 Server a. Map network drives on Windows 2008 Server hosts. 24 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
25 Configure DUT and Test Equipment FIGURE 19 Windows 2008 Network Drive Mapping - Screen 1 FIGURE 20 Windows 2008 Network Drive Mapping - Screen 2 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 25
26 Task 4. Red Hat Linux Host Configuration Task 4. Red Hat Linux Host Configuration This task describes configuring NIC bonding and mounting shares on Red Hat Linux. 1. Configure NIC Bonding The following are the entries within /etc/sysconfig/network-scripts/ on Red Hat hosts to enable Ethernet bonding, or NIC bonding. < =========== > ifcfg-eth4 DEVICE=eth4 BOOTPROTO=none ONBOOT=yes MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED=no ifcfg-eth5 DEVICE=eth5 BOOTPROTO=none ONBOOT=yes MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED=no ifcfg-bond0 DEVICE=bond0 IPADDR= NETMASK= ONBOOT=yes BOOTPROTO=none USERCTL=no NM_CONTROLLED=no BONDING_OPTS="mode=802.3ad miimon=100 downdelay=5000 updelay=5000" < =========== > 2. Mount NFS Disk Shares The following commands mount NetApp 3170 NFS shares on hosts hosts running Red Hat 6.5 or 6.3. < =========== > mount -t nfs :/REDHAT_ /mnt/netapp3170 mount -t nfs :/REDHAT_ /mnt/netapp3170 < =========== > Task 5. Medusa I/O Generation Configuration The following shows the configuration of the Medusa I/O data patterns used in the test cases. 1. Standard I/O with 64KB Blocks For test scenarios using standard I/O (64-KB testing size), configure Medusa for the following command line result: < =========== > pain 2GB -b64kb -t8 -v2 -H45 -l35 -Y1 M45 < =========== > 2. Maximum I/O with 1-MB Blocks 26 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
27 Configure DUT and Test Equipment For test scenarios using maximum bandwidth I/O (1-MB testing size), configure Medusa for the following command line result: < =========== > maim 2GB -b1mb -Q8 -n -u -q5 -w -o -Y1 M45 --perf-mode < =========== > 3. Microsoft Exchange Server I/O For test scenarios using Microsoft Exchange Server Simulation (Medusa preconfigured Storage Simulation test), configure Medusa for the following command line result: < =========== > maim 2GB -Q1 -n -u -q5 -o -l69 -Y1 -M45 < =========== > 4. File Server I/O For test scenarios using File Server Simulation (Medusa preconfigured Storage Simulation test), configure Medusa for the following command line result: < =========== > maim 2GB - -%2:r50@8KB,w50@8KB - -%10:r80@64KB,w20@64KB -Q1 -n -u -o -l69 -Y1 -M45 < =========== > Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 27
28 NOS Test Report NOS Test Report Test Plan...28 Test Cases...34 Test Conclusions...46 Test Plan The storage array is connected to one VDX Ethernet fabric with multiple Windows and Red Hat server hosts to drive I/O. Scope Testing will be performed with Brocade's Network Operating System (NOS) in a heterogeneous environment. Test beds will include Brocade switches configured in routed and non-routed fabric configurations. Testing is centered on interoperability and optimal configuration. Performance is observed within the context of best practice fabric configuration; however absolute maximum benchmark reporting of storage performance is beyond the scope of this test. 28 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
29 Test Configuration Test Configuration FIGURE 21 Test Topology The following diagram shows Brocade VCS Fabric switch port connections and vlag (port-channel) ports for each server and the NetApp 3170 array. For example, 1/0/1 means the device port connects to RBridge# = 1, Card# = 0, and Port# = 1. For fixed top-of-rack switches such as the Brocade VDX 6720, 6730, and 6740, there are no port cards, which is indicated by 0 for the Card#. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 29
30 DUT Descriptions FIGURE 22 Device to VCS Fabric Switch Port Connections DUT Descriptions The following tables provide details about the devices under test (DUTs). TABLE 1 Storage Array Model Vendor Description FAS3170 NetApp Network attached storage (NAS) array TABLE 2 Switches Model Vendor Description 30 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
31 DUT Specifications TABLE 2 Switches (Continued) BR-VDX6740 Brocade The Brocade VDX 6740 and 6740T are Ethernet fabric top-of-rack (ToR) switches featuring 10-GbE ports with 40-GbE uplinks. The Brocade VDX 6740T-1G Switch offers dual-speed functionality. It can be deployed with1000base-t for existing 1- GbE server connectivity and upgraded via software to 10GBASE-T for future bandwidth growth. Together with Brocade VCS Fabric technology, these switches deliver the high performance and low latency needed to support demanding virtualized data center environments. DUT Specifications NAS Array Version NetApp Mode NetApp OnCommand System Manager Version 3.1 (3.1.2RC2) Brocade Switches Device ID Version VDX 6740 CASTOR-VCS20-1 Network OS VDX 6740 CASTOR-VCS20-2 Network OS VDX 6740 CASTOR-VCS20-11 Network OS VDX 6740 CASTOR-VCS20-12 Network OS Adapters Version Brocade (Red Hat Enterprise Linux 6.6) Brocade (Windows Server 2008) Brocade (ESXi 5.5u2) Emulex OCe (Windows Server 2012) Servers Memory Processor IBM x3650 M3 8 GB 2.13 GHz IBM x3650 M3 32 GB 2.13 GHz HP ProLiant DL380 G7 8 GB 2.13 GHz Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 31
32 DUT Configuration HP ProLiant DL380 G7 8 GB 2.13 GHz Cisco UCS B200 M3 (x4) 64 GB 2.10 GHz (x2) Operating Systems ESXi ESXi Guests Version 5.5u2 (x2) Windows Server 2012 R2 (x2), Red Hat Enterprise Linux 6.6, Red Hat Enterprise Linux 7.0, SUSE Linux Enterprise Server 11.3 Red Hat Enterprise Linux Server 6.6, 7.0 SUSE Linux Enterprise Server 11.3 Windows Server Windows Server 2008 R2, Windows Server 2012 R2 (x2) Test Equipment Version Medusa Labs Test Tools Device Interface IP Address NetApp 3170 node4, e4a NetApp 3170 node3, VIF NOS_VCS Windows 2012 Server NIC Team Windows 2008 Server NIC Team Red Hat 6.6 Server bond Windows 2012 Server Cisco VIC Ethernet Red Hat 7.0 Server Cisco VIC enp8s SUSE Linux Server Cisco VIC eth ESXi 5.5u2 Server Cisco VIC vswitch ESXi 5.5u2 Server vswitch DUT Configuration < ========== > interface Vlan 979 rbridge-id 1 interface Ve 979 ip address /16 32 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
33 NOS Test Report rbridge-id 2 interface Ve 979 ip address /16 rbridge-id 11 interface Ve 979 ip address /16 rbridge-id 12 interface Ve 979 ip address /16 interface TenGigabitEthernet 1/0/1 no no channel-group 101 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/2 no no channel-group 102 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/3 no no channel-group 103 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/4 no no channel-group 104 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/1 no no channel-group 101 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/2 no no channel-group 102 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/3 no no channel-group 103 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/4 no no channel-group 104 mode active type standard lacp timeout long interface TenGigabitEthernet 11/1/3 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 33
34 Test Cases no no channel-group 21 mode active type standard lacp timeout long interface TenGigabitEthernet 11/1/4 cee default no no switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 12/0/3 no no channel-group 21 mode active type standard lacp timeout long interface Port-channel 21 cee default vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 101 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 102 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 103 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 104 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown < ========== > Test Cases The following test cases are designed to verify basic and advanced functionality features between the Brocade VCS cluster and host and storage devices, as well as to stress all devices and confirm successful error recovery. 34 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
35 NOS Test Report 1.1 Base Functionality Physical Connection and Speed Negotiation Storage Connectivity Virtual LAG Connectivity 1.2 Advanced Functionality MTU Jumbo Frame Maximum Bandwidth Congested Fabric with Auto-NAS Jammer CRC Corruption on an ISL Port Jammer Packet Corruption on an ISL Port Jammer Packet Loss on an ISL Port Jammer CRC Corruption on a Storage Port Jammer Packet Corruption on a Storage Port Jammer Packet Loss on a Storage Port ISL Congestion and Interface Buffer Queue Length 1.3 Stress and Error Recovery Congested Fabric with Auto-NAS Extended Run Manual Cable Pull ISL Port Relocation Device Port Toggle Extended Run ISL Port Toggle Extended Run Split Brain Recovery Brocade VDX 8770 Line-Card Maintenance Extended Run Switch Offline Workload Simulation Microsoft Exchange Server Workload Simulation File Server Host-side Interface Port Toggle Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 35
36 1.1 Base Functionality Storage-side Interface Port Toggle Storage Failover 1.4 Brocade Network Advisor Ethernet Fabric Discovery Ethernet Fabric Addition and Removal Ethernet Fabric Configuration Backup and Restoration Ethernet Fabric Firmware Download 1.1 Base Functionality Physical Connection and Speed Negotiation Test Objective Test storage device connectivity to the Brocade VDX switch with supported speed and duplex settings. Validation Verify that Brocade VDX console output shows expected speed and duplex settings for all connected physical interfaces. Verify that storage device console or GUI output shows expected speed and duplex settings for all connected physical interfaces. Results PASS. All interfaces are up and operational at expected speed settings. Brocade VDX show interface commands reflect expected interface speed Storage Connectivity Test Objective Test end-to-end connectivity between hosts and the storage device. Validation Verify that hosts can mount shares on the storage device. Results PASS. All NAS targets on Windows, Red Hat, and ESXi hosts are successfully connected. 36 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
37 1.1.3 Virtual LAG Connectivity Virtual LAG Connectivity Test Objective Test that Brocade VCS vlag connectivity can be established with both hosts and storage devices. Validation All host and storage link aggregation ports sync with Brocade VCS vlag ports. Results PASS. All port-channel interfaces are operational and in sync. 1.2 Advanced Functionality MTU Jumbo Frame Test Objective Test the maximum transmission unit (MTU) supported by all devices in the I/O path. Validation All I/O runs error-free at the maximum frame size for a minimum of 15 minutes. Results PASS. All nonfragmented ping packets are successfully responded to, and all jumbo frame storage traffic completes error-free Maximum Bandwidth Test Objective Test host-to-storage traffic using an I/O generator configured for maximum throughput. Validation All I/O runs error-free at the maximum throughput for a minimum of 15 minutes. Results PASS. All I/O completes error-free. All host and storage ports show bandwidth under maximum capacity. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 37
38 1.2.3 Congested Fabric with Auto-NAS Congested Fabric with Auto-NAS Test Objective Test host-to-storage traffic using an I/O generator configured for maximum throughput while configured with Brocade VCS Auto-NAS enabled and additional Layer 3 FCoE and Layer 2 Ethernet traffic to congest ISL links. Validation All storage I/O runs error-free at the maximum throughput for a minimum of 15 minutes. Background traffic can experience congestion errors. Results PASS. NAS I/O completes error-free through bandwidth congestion Jammer CRC Corruption on an ISL Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of CRC packet corruptions on an ISL port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer CRC corruption on the ISL port Jammer Packet Corruption on an ISL Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet corruptions on an ISL port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet corruption on the ISL port. 38 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
39 1.2.6 Jammer Packet Loss on an ISL Port Jammer Packet Loss on an ISL Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet loss on an ISL port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet loss on the ISL port Jammer CRC Corruption on a Storage Port Test Objective Verify that end-to-end storage traffic can be maintained through a short burst of CRC packet corruptions on a storage port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet corruption on the storage port Jammer Packet Corruption on a Storage Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet corruptions on a storage port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet corruption on the storage port. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 39
40 1.2.9 Jammer Packet Loss on a Storage Port Jammer Packet Loss on a Storage Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet loss on a storage port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet loss on the storage port ISL Congestion and Interface Buffer Queue Depth Test Objective Verify that increasing ISL interface buffer queues in an ISL congestion scenario eliminates tail-end packet drops and improves throughput. Validation 1. Disable as many ISLs as necessary to force end-to-end IP storage traffic through a single ISL. 2. Initiate multiple host read I/O traffic streams that produce consistent TX packet drops, and observe packet drops on the many-to-one ISL interface queue as well as average throughput over a 30- minute period. 3. Increase ISL interface buffer queue depth above default values, and repeat multiple host read I/O traffic steams. Results PASS. When transmit queue buffers are increased, average I/O throughput increases and packet drops decrease. 1.3 Stress and Error Recovery Congested Fabric with Auto-NAS Extended Run Test Objective Test host-to-storage traffic using an I/O generator configured for maximum throughput while configured with Brocade VCS Auto-NAS enabled and additional Layer 3 FCoE and Layer 2 Ethernet traffic to congest ISL links over a 12-hour period. 40 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
41 1.3.2 Manual Cable Pull Validation All storage I/O runs error-free at maximum throughput for a minimum of 12 hours. Background traffic can experience congestion errors. Results PASS. All I/O completes error-free through Brocade VCS Fabric congestion Manual Cable Pull Test Objective Test that host-to-storage traffic can maintain I/O during a quick port toggle on every storage and host port. Validation All storage I/O runs error-free during each rapid port toggle. Results PASS. All I/O recovers during port disconnections and reconnections ISL Port Relocation Test Objective Test that host-to-storage traffic can maintain I/O during ISL relocation within the same switch on all VCS nodes. Validation All storage I/O runs error-free during each ISL port relocation. Results PASS. The Brocade VCS Fabric reforms properly and all I/O recovers during ISL port disconnections and reconnections Device Port Toggle Extended Run Test Objective Test that host-to-storage traffic can maintain I/O during sequential host and storage port disabling and enabling over a 12-hour period. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 41
42 1.3.5 ISL Port Toggle Extended Run Validation All storage I/O runs error-free during host and storage port disable and enable actions for a minimum of 12 hours. Results PASS. All I/O recovers during all initiator and target port disabling and enabling ISL Port Toggle Extended Run Test Objective Test that host-to-storage traffic can maintain I/O through ISL port disabling and enabling over a 12- hour period. Validation All storage I/O runs error-free during ISL port disable and enable actions for a minimum of 12 hours. Results PASS. All I/O completes error-free during ISL port disable and enable commands Split Brain Recovery Test Objective Test that host-to-storage traffic can recover while disabling and enabling all ISL ports sequentially on each switch in the VCS cluster. Validation 1. Disable all ISL ports on a single switch, and wait for the VCS cluster to segment. 2. Enable all ISL ports on the same switch, and wait for the VCS cluster to reform. 3. Repeat for each switch in the VCS cluster. Results PASS. All I/O recovers after ISL port disable and enable commands Brocade VDX 8770 Line-Card Maintenance Extended Run Test Objective Test that host-to-storage traffic can be maintained during line-card power-off and power-on commands sequentially on each Brocade VDX 8770 line card in the VCS cluster. 42 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
43 1.3.8 Switch Offline Validation All storage I/O runs error-free during line-card power-off and power-on actions for a minimum of 12 hours. Results N/A. The Brocade VDX 8770 is not present in the network configuration Switch Offline Test Objective Test that host-to-storage traffic can be maintained during chassis disable and enable commands, switch reloads, and chassis power cycles sequentially on each Brocade VDX in the VCS cluster. Validation All storage I/O runs error-free during chassis disable and enable commands, switch reloads, and chassis power cycles. Results Chassis Disable/Enable: PASS. I/O successfully resumes after the chassis is enabled. Reboot: PASS. I/O successfully resumes after the chassis is rebooted. Power Cycle: PASS. I/O successfully resumes after the chassis is power-cycled Workload Simulation Microsoft Exchange Server Test Objective Test host-to-storage traffic using the Medusa Microsoft Exchange Server workload simulation suite. Validation All storage I/O runs error-free for a minimum of 30 minutes. Results PASS. All I/O completes error-free Workload Simulation File Server Test Objective Test host-to-storage traffic using the Medusa File Server workload simulation suite. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 43
44 Host-side Interface Port Toggle Validation All storage I/O runs error-free for a minimum of 30 minutes. Results PASS. All I/O completes error-free Host-side Interface Port Toggle Test Objective Test that host-to-storage traffic can be maintained while sequentially disabling and enabling connections to the VCS cluster from the host side. Validation All storage I/O runs error-free during host-side interface disable and enable actions. Results PASS. All I/O completes error-free during host-side interface disable and enable actions Storage-side Interface Port Toggle Test Objective Test that host-to-storage traffic can be maintained while sequentially disabling and enabling connections to the VCS cluster from the storage side. Validation All storage I/O runs error-free during storage-side interface disable and enable actions. Results PASS. All I/O completes error-free during storage-side interface disable and enable actions. Storage does not allow individual interfaces to be manipulated if they are part of a trunk group. Testing only validated that traffic recovered after the trunk group was disabled and enabled Storage Failover Test Objective Test that storage node redundancy failover occurs within the expected storage node feature set. 44 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
45 1.4 Brocade Network Advisor Validation All storage I/O runs error-free (if lossless failover is supported) during the storage failover action, or traffic successfully resumes after the storage failover action is complete (if lossless failover is not supported). Results PASS. I/O successfully resumes after the node is rebooted. 1.4 Brocade Network Advisor Ethernet Fabric Discovery Test Objective Test the Brocade Network Advisor Ethernet fabric discovery. Validation Brocade Network Advisor successfully discovers the VCS cluster. Results PASS. The VCS cluster is successfully discovered Ethernet Fabric Addition and Removal Test Objective Test the Brocade Network Advisor Ethernet fabric node addition and removal. Validation Brocade Network Advisor successfully tracks both VCS node addition and removal. Results PASS. Brocade Network Advisor accurately reports the VCS cluster changes during both removal and addition Ethernet Fabric Configuration Backup and Restoration Test Objective Test the Brocade Network Advisor Ethernet fabric configuration backup and restoration. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 45
46 1.4.4 Ethernet Fabric Firmware Download Validation The Brocade Network Advisor successfully performs configuration backup and restoration. Results PASS. Brocade Network Advisor successfully performs both configuration backup and restoration Ethernet Fabric Firmware Download Test Objective Test the Brocade Network Advisor Ethernet fabric firmware download. Validation Brocade Network Advisor successfully downloads firmware to all VCS cluster nodes. Results PASS. Brocade Network Advisor successfully performs firmware download to Network OS Test Conclusions 1. Brocade VCS Fabric technology and the NetApp 3170 NAS array smoothly interoperate with both redundant and nonredundant configurations. No exceptions were noted. 2. The configuration procedures followed Brocade VCS Fabric and NetApp 3170 standard documentation guides and found no issues with these procedures. 3. All simulated changes in network and storage (add, remove, fail over) resulted in expected behavior and I/O recovery. 46 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
47 NOS Test Report Test Plan Test Cases Test Conclusions...93 Test Plan The storage array is connected to one VDX Ethernet fabric with multiple Windows and Red Hat server hosts to drive I/O. Scope Testing will be performed with Brocade's Network Operating System (NOS) in a heterogeneous environment. Test beds will include Brocade switches configured in routed and non-routed fabric configurations. Testing is centered on interoperability and optimal configuration. Performance is observed within the context of best practice fabric configuration; however absolute maximum benchmark reporting of storage performance is beyond the scope of this test. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 47
48 Test Configuration Test Configuration FIGURE 23 Test Topology The following diagram shows Brocade VCS Fabric switch port connections and vlag (port-channel) ports for each server and the NetApp 3170 array. For example, 1/0/1 means the device port connects to RBridge# = 1, Card# = 0, and Port# = 1. For fixed top-of-rack switches such as the Brocade VDX 6720, 6730, and 6740, there are no port cards, which is indicated by 0 for the Card#. 48 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
49 DUT Descriptions FIGURE 24 Device to VCS Fabric Switch Port Connections DUT Descriptions The following tables provide details about the devices under test (DUTs). TABLE 3 Storage Array Model Vendor Description FAS3170 NetApp Network attached storage (NAS) array TABLE 4 Switches Model Vendor Description Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 49
50 DUT Specifications TABLE 4 Switches (Continued) BR-VDX Brocade The Brocade VDX 6720 is a high-performance, ultra-low latency wire-speed 10 Gigabit Ethernet (GbE) fixed configuration switch. The VDX 6720 has been superseded by the VDX 6740 which is the latest generation of ToR switch in the VDX Switch family offering more bandwidth (40 GE) and options for 10BASE-T connectivity. BR-VDX Brocade The Brocade VDX 6730 Switch is a 10 Gigabit Ethernet (GbE) fixed configuration switch with LAN and native Fibre Channel ports. It supports multiple connectivity options, Ethernet storage connectivity for Fibre Channel over Ethernet (FCoE), iscsi, NAS, and bridges to Fibre Channel Storage Area Networks (SANs). BR-VDX6740 Brocade The Brocade VDX 6740 and 6740T are Ethernet fabric Top of Rack (ToR) switches featuring 10 GbE ports with 40 GbE uplinks. The new Brocade VDX 6740T-1G Switch offers dual-speed functionality. It can be deployed with1000baset for existing 1 GbE server connectivity and upgraded via software to 10GBASE-T for future bandwidth growth. Together with Brocade VCS Fabric technology, these switches deliver the high performance and low latency needed to support demanding virtualized data center environments. BR-VDX Brocade The Brocade VDX 8770 Switch is a highly scalable, low-latency, 1/10/40/100 Gigabit Ethernet (GbE) modular switch. Designed to easily scale out Brocade VCS fabrics, the Brocade VDX 8770 Switch brings new levels of performance to VCS fabric deployments. DUT Specifications NAS Array NetApp 3170 NetApp OnCommand System Manager Version NetApp Release Mode Version 3.1 (3.1.1RC1) QLogic CNA 8152 Firmware Revision Brocade Switches Version VDX 6720 Network OS VDX 6730 Network OS VDX 6740 Network OS Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
51 NOS Test Report VDX 8770 Network OS Adapters Brocade 1020 Brocade 1860 Emulex OCe14102 Version (Windows), (Red Hat) (Windows) p (Red Hat) Servers Memory Processor IBM x3650 M3 8 GB 2.13 GHz (x4) IBM x3650 M3 8 GB 2.13 GHz (x4) HP ProLiant DL380 G7 8 GB 2.13 GHz HP ProLiant DL380 G7 8 GB 2.13 GHz (x4) Operating Systems Version Red Hat Enterprise Linux Server 6.5, 6.3 Windows Server 2008 R2, 2012 R2 Test Equipment Version Medusa Labs Test Tools Device Interface IP Address NetApp 3170 node4, e4a NetApp 3170 node3, VIF NOS_VCS Windows 2012 Server NIC Team Windows 2008 Server NIC Team Red Hat 6.5 Server bond Red Hat 6.3 Server bond Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 51
52 DUT Configuration DUT Configuration < ========== > interface Vlan 979 rbridge-id 1 interface Ve 979 ip address /16 rbridge-id 2 interface Ve 979 ip address /16 rbridge-id 11 interface Ve 979 ip address /16 rbridge-id 12 interface Ve 979 ip address /16 interface TenGigabitEthernet 1/0/1 no no channel-group 101 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/2 no no channel-group 102 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/3 no no channel-group 103 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 2/0/1 no no channel-group 101 mode active type standard lacp timeout long 52 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
53 NOS Test Report interface TenGigabitEthernet 2/0/2 no no channel-group 102 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/3 no no channel-group 103 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 11/0/3 no no channel-group 21 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/4 cee default no no switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 12/0/3 no no channel-group 21 mode active type standard lacp timeout long interface Port-channel 21 cee default vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 101 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 102 vlag ignore-split Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 53
54 Test Cases switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 103 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 105 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add 979 switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 106 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add 979 switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 107 no vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add 979 switchport trunk tag native-vlan spanning-tree shutdown < ========== > Test Cases The following test cases are designed to verify basic and advanced functionality features between the Brocade VCS cluster and host and storage devices, as well as to stress all devices and confirm successful error recovery. 1.1 Ethernet Storage - Base Functionality Storage Device - Physical Connection and Speed Negotiation NAS Connectivity vlag Connectivity 1.2 Ethernet Storage - Advanced Functionality Storage Device - Jumbo Frame/MTU Size Validation NAS Bandwidth Validation 54 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
55 1.1 Ethernet Storage - Base Functionality Storage Device - w/congested Fabric Storage Device - NAS Protocol Jammer CRC Corruption on ISL Port Storage Device - NAS Protocol Jammer Packet Corruption on ISL Port Storage Device - NAS Protocol Jammer Packet Loss on ISL Port Storage Device - NAS Protocol Jammer CRC Corruption on Storage Port Storage Device - NAS Protocol Jammer Packet Corruption on Storage Port Storage Device - NAS Protocol Jammer Packet Loss on Storage Port 1.3 Stress and Error Recovery Storage Device Fabric IO Integrity - Congested Fabric Storage Device Integrity - Device Recovery from Port Toggle - Manual Cable Storage Device Integrity - Device Recovery from ISL Port Relocation Storage Device Stress - Device Recovery from Device Port Toggle - Extended Run Storage Device Recovery - ISL Port Toggle - Extended Run Storage Device Recovery - All-ISL Port Toggle Storage Device Recovery - VDX 8770 Line Card Maintenance Storage Device Recovery - Switch Offline Storage Device Recovery - Switch Firmware Download ISSU on VDX Workload Simulation Test Suite - Microsoft Exchange Server Workload Simulation Test Suite - File Server Simulation Test Case Descriptions Lines marked with ' < == ' indicate important output used to validate the test results. 1.1 Ethernet Storage - Base Functionality Storage Device - Physical Connection and Speed Negotiation Test Objective Verify device connectivity to VDX switch with all supported speed settings. Configure storage port for iscsi connectivity. Validate base connectivity. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 55
56 1.1.2 NAS Connectivity Results PASS. All interfaces are up and operational at the expected speed settings. Brocade VDX show interface commands reflect the expected interface speed. < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/3 TenGigabitEthernet 11/1/3 is up, line protocol is up (connected) < == Hardware is Ethernet, address is 0027.f81c.71d0 Current address is 0027.f81c.71d0 Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit < == LineSpeed Configured : Auto, Duplex: Full... CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) < == Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit < == LineSpeed Configured : Auto, Duplex: Full... CASTOR-VCS20-12# show interface tengigabitethernet 12/0/3 TenGigabitEthernet 12/0/3 is up, line protocol is up (connected) < == Hardware is Ethernet, address is Current address is Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit < == LineSpeed Configured : Auto, Duplex: Full... < =========== > NAS Connectivity Test Objective Verify host to File Share connectivity with CIFS and NFS with multiple simultaneous connections. Results PASS. All network drives on all Windows and Red Hat hosts are successfully mapped. < =========== > PS C:\Users\Administrator> net use New connections will be remembered. Status Local Remote Network OK J: \\ \WINDOWS_68114 Microsoft Windows Network < == OK K: \\ \WINDOWS_68114 Microsoft Windows Network < == \\TSCLIENT\C Microsoft Terminal Services The command completed successfully. C:\Users\Administrator>net use New connections will be remembered. Status Local Remote Network Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
57 1.1.3 vlag Connectivity OK J: \\ \WINDOWS_68128 Microsoft Windows Network < == OK K: \\ \WINDOWS_68128 Microsoft Windows Network < == \\TSCLIENT\C Microsoft Terminal Services The command completed successfully. ~]# df Filesystem 1K-blocks Used Available Use% Mounted on :/vol/REDHAT_ % /mnt/netapp3170 < == ~]# df Filesystem 1K-blocks Used Available Use% Mounted on :/vol/REDHAT_66109 < == % /mnt/netapp3170 < == < =========== > vlag Connectivity Test Objective Configure vlag connectivity from Storage Ports to 2 separate VDX switches. Verify data integrity through vlag. Results PASS. All port-channel interfaces are operational and in sync. < =========== > CASTOR-VCS20-12# show port-channel 21 LACP Aggregator: Po 21 (vlag) Aggregator type: Standard Ignore-split is enabled Member rbridges: rbridge-id: 11 (1) rbridge-id: 12 (1) Admin Key: Oper Key 0021 Partner System ID - 0x0001,02-a Partner Oper Key 0001 Member ports on rbridge-id 11: Link: Te 11/1/3 (0xB ) sync: 1 * < == Member ports on rbridge-id 12: Link: Te 12/0/3 (0xC ) sync: 1 < == CASTOR-VCS20-12# show port-channel 101 LACP Aggregator: Po 101 (vlag) Aggregator type: Standard Ignore-split is enabled Member rbridges: rbridge-id: 1 (1) rbridge-id: 2 (1) Admin Key: Oper Key 0101 Partner System ID - 0x0000,00-90-fa-6c-01-ae Partner Oper Key 0000 Member ports on rbridge-id 1: Link: Te 1/0/1 (0x ) sync: 1 * < == Member ports on rbridge-id 2: Link: Te 2/0/1 (0x ) sync: 1 < == CASTOR-VCS20-12# show port-channel 102 LACP Aggregator: Po 102 (vlag) Aggregator type: Standard Ignore-split is enabled Member rbridges: rbridge-id: 1 (1) rbridge-id: 2 (1) Admin Key: Oper Key 0102 Partner System ID - 0xffff,8c-7c-ff Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 57
58 1.2 Ethernet Storage - Advanced Functionality Partner Oper Key 0017 Member ports on rbridge-id 1: Link: Te 1/0/2 (0x ) sync: 1 * < == Member ports on rbridge-id 2: Link: Te 2/0/2 (0x ) sync: 1 < == CASTOR-VCS20-12# show port-channel 103 LACP Aggregator: Po 103 (vlag) Aggregator type: Standard Ignore-split is enabled Member rbridges: rbridge-id: 1 (1) rbridge-id: 2 (1) Admin Key: Oper Key 0103 Partner System ID - 0xffff, c-12 Partner Oper Key 0033 Member ports on rbridge-id 1: Link: Te 1/0/3 (0x ) sync: 1 < == Member ports on rbridge-id 2: Link: Te 2/0/3 (0x ) sync: 1 * < == CASTOR-VCS20-12# show port-channel 104 LACP Aggregator: Po 104 (vlag) Aggregator type: Standard Ignore-split is enabled Member rbridges: rbridge-id: 1 (1) rbridge-id: 2 (1) Admin Key: Oper Key 0104 Partner System ID - 0xffff,00-00-c9-b1-e5-c2 Partner Oper Key 0033 Member ports on rbridge-id 1: Link: Te 1/0/4 (0x ) sync: 1 < == Member ports on rbridge-id 2: Link: Te 2/0/4 (0x ) sync: 1 * < == < =========== > 1.2 Ethernet Storage - Advanced Functionality Storage Device - Jumbo Frame/MTU Size Validation Test Objective Perform I/O validation testing while incrementing MTU size from minimum to maximum with reasonable increments. Include Jumbo frame sizes as well as maximum negotiated/supported between device and switch. Test Configuration 1. Open the NetApp OnCommand System Manager and navigate to Configuration -> Network -> Network Interfaces. Then, highlight the desired network interface and click Edit. Click on the Advanced tab and change the entry for MTU Size (in bytes) to the desired value. Finally, click Save and Close. 58 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
59 NOS Test Report FIGURE 25 NetApp 3170 MTU Configuration 2. For Red Hat hosts, add "MTU=9000" to /etc/sysconfig/network-scripts/ifcfg-bond0 and then execute service network restart. < =========== > ~]# more /etc/sysconfig/network-scripts/ifcfg-bond0 DEVICE=bond0 IPADDR= NETMASK= ONBOOT=yes BOOTPROTO=none MTU=9000 USERCTL=no NM_CONTROLLED=no BONDING_OPTS="mode=802.3ad miimon=100 downdelay=5000 updelay=5000" ~]# < =========== > 3. For Windows 2012 Server host, reconfigure individual NIC team members for increased MTU size. Perform Disable and Enable on NIC Team interface within Windows to apply packet size change. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 59
60 NOS Test Report FIGURE 26 Windows 2012 Server Emulex NIC MTU Configuration 4. For Windows 2008 Server host, reconfigure NIC team interface. 60 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
61 NOS Test Report FIGURE 27 Windows 2008 Server Brocade NIC MTU Configuration 5. On VDX devices, configure as follows: < =========== > rbridge-id 1 interface ve 979 ip mtu 9018 rbridge-id 2 interface ve 979 ip mtu 9018 rbridge-id 11 interface ve 979 ip mtu 9018 rbridge-id 12 interface ve 979 ip mtu 9018 interface TenGigabitEthernet 11/1/4 mtu 9216 interface Port-Channel 21 mtu 9216 interface Port-Channel 101 mtu 9216 interface Port-Channel 102 mtu 9216 interface Port-Channel 103 mtu 9216 interface Port-Channel 104 mtu 9216 < =========== > Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 61
62 NOS Test Report Results PASS. Non-fragmented ping packets were successfully responded to and all jumbo frame storage traffic was error-free. < =========== > PS C:\Users\Administrator> ping l f Pinging with 8972 bytes of data: Reply from : bytes=8972 time<1ms TTL=255 Reply from : bytes=8972 time<1ms TTL=255 Reply from : bytes=8972 time<1ms TTL=255 Reply from : bytes=8972 time<1ms TTL=255 Ping statistics for : Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), < == Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms C:\Users\Administrator>ping l f Pinging with 8972 bytes of data: Reply from : bytes=8972 time<1ms TTL=255 Reply from : bytes=8972 time<1ms TTL=255 Reply from : bytes=8972 time<1ms TTL=255 Reply from : bytes=8972 time<1ms TTL=255 Ping statistics for : Packets: Sent = 4, Received = 4, Lost = 0 (0% loss), < == Approximate round trip times in milli-seconds: Minimum = 0ms, Maximum = 0ms, Average = 0ms [root@ilo65205 ~]# ping -c 4 -M do -s PING ( ) 8972(9000) bytes of data bytes from : icmp_seq=1 ttl=255 time=0.161 ms 8980 bytes from : icmp_seq=2 ttl=255 time=0.160 ms 8980 bytes from : icmp_seq=3 ttl=255 time=0.166 ms 8980 bytes from : icmp_seq=4 ttl=255 time=0.160 ms ping statistics packets transmitted, 4 received, 0% packet loss, time 2999ms < == rtt min/avg/max/mdev = 0.160/0.161/0.166/0.015 ms [root@v-e-vmw ~]# ping -c 4 -M do -s PING ( ) 8972(9000) bytes of data bytes from : icmp_seq=1 ttl=255 time=0.730 ms 8980 bytes from : icmp_seq=2 ttl=255 time=0.224 ms 8980 bytes from : icmp_seq=3 ttl=255 time=0.225 ms 8980 bytes from : icmp_seq=4 ttl=255 time=0.232 ms ping statistics packets transmitted, 4 received, 0% packet loss, time 3000ms < == rtt min/avg/max/mdev = 0.224/0.352/0.730/0.219 ms < =========== > 62 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
63 NOS Test Report < =========== > CASTOR-VCS20-12# show interface port-channel 101 Port-channel 101 is up, line protocol is up Hardware is AGGREGATE, address is b.a6ca Current address is b.a6ca Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:15:14 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 4810, Broadcasts: byte pkts: , Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 1468, Over 511-byte pkts: 5830, Over 1023-byte pkts: 2474 Over 1518-byte pkts(jumbo): < == Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 1946, Broadcasts: 657 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, 3491 packets/sec, 0.01% of line-rate Output Mbits/sec, 9358 packets/sec, 3.09% of line-rate Time since last interface status change: 00:22:28 CASTOR-VCS20-12# show interface port-channel 102 Port-channel 102 is up, line protocol is up Hardware is AGGREGATE, address is b.a6c8 Current address is b.a6c8 Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:15:14 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 161, Broadcasts: byte pkts: , Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 3536, Over 511-byte pkts: 8108, Over 1023-byte pkts: 1272 Over 1518-byte pkts(jumbo): < == Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 177, Broadcasts: 470 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, 3379 packets/sec, 0.01% of line-rate Output Mbits/sec, 9283 packets/sec, 3.07% of line-rate Time since last interface status change: 00:23:42 CASTOR-VCS20-12# show interface port-channel 103 Port-channel 103 is up, line protocol is up Hardware is AGGREGATE, address is b.a6c7 Current address is b.a6c7 Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 63
64 NOS Test Report Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:15:14 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 123, Broadcasts: 6 64-byte pkts: 75, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 5959, Over 511-byte pkts: 5145, Over 1023-byte pkts: 2576 Over 1518-byte pkts(jumbo): < == Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 213, Broadcasts: 751 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 4.73% of line-rate Output Mbits/sec, 9046 packets/sec, 0.03% of line-rate Time since last interface status change: 00:29:33 CASTOR-VCS20-12# show interface port-channel 104 Port-channel 104 is up, line protocol is up Hardware is AGGREGATE, address is b.a6c9 Current address is b.a6c9 Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:15:15 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 3890, Broadcasts: 7 64-byte pkts: 3844, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 9238, Over 511-byte pkts: 5880, Over 1023-byte pkts: 2104 Over 1518-byte pkts(jumbo): < == Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 218, Broadcasts: 744 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 4.13% of line-rate Output Mbits/sec, 8108 packets/sec, 0.03% of line-rate Time since last interface status change: 00:30:15 CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:15:15 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 9018, Broadcasts: byte pkts: , Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 22, Over 511-byte pkts: 1, Over 1023-byte pkts: 1 Over 1518-byte pkts(jumbo): < == Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 155, Broadcasts: 557 Underruns: 0 64 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
65 1.2.2 NAS Bandwidth Validation Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 12.58% of line-rate Output Mbits/sec, packets/sec, 16.95% of line-rate Time since last interface status change: 1d18h17m NAS Bandwidth Validation Test Objective Validate maximum sustained bandwidth to storage port via CIFS/NFS. After 15 minutes, verify I/O completes error-free. Results PASS.All IO completes error-free.all host and storage ports show bandwidth under maximum capacity. < =========== > CASTOR-VCS20-12# show interface port-channel 101 Port-channel 101 is up, line protocol is up Hardware is AGGREGATE, address is b.a6c9 Current address is b.a6c9 Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:21:12 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 6667, Broadcasts: byte pkts: , Over 64-byte pkts: 235, Over 127-byte pkts: Over 255-byte pkts: 42092, Over 511-byte pkts: , Over 1023-byte pkts: Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 2700, Broadcasts: 927 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 1.76% of line-rate < == Output Mbits/sec, packets/sec, 0.04% of line-rate Time since last interface status change: 4d04h17m CASTOR-VCS20-12# show interface port-channel 102 Port-channel 102 is up, line protocol is up Hardware is AGGREGATE, address is b.a6c7 Current address is b.a6c7 Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:21:12 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 231, Broadcasts: byte pkts: , Over 64-byte pkts: 188, Over 127-byte pkts: Over 255-byte pkts: 55743, Over 511-byte pkts: , Over 1023-byte pkts: Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 65
66 NOS Test Report Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 207, Broadcasts: 633 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 2.03% of line-rate < == Output Mbits/sec, packets/sec, 0.05% of line-rate Time since last interface status change: 4d04h16m CASTOR-VCS20-12# show interface port-channel 103 Port-channel 103 is up, line protocol is up Hardware is AGGREGATE, address is b.a6ca Current address is b.a6ca Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:21:12 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 169, Broadcasts: 8 64-byte pkts: 112, Over 64-byte pkts: , Over 127-byte pkts: 106 Over 255-byte pkts: 372, Over 511-byte pkts: 76, Over 1023-byte pkts: Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 296, Broadcasts: 1013 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 2.86% of line-rate < == Output Mbits/sec, packets/sec, 0.07% of line-rate Time since last interface status change: 21:31:03 CASTOR-VCS20-12# show interface port-channel 104 Port-channel 104 is up, line protocol is up Hardware is AGGREGATE, address is b.a6c8 Current address is b.a6c8 Interface index (ifindex) is Minimum number of links to bring Port-channel up is 1 MTU 9216 bytes LineSpeed Actual : Mbit Allowed Member Speed : Mbit Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:21:12 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 5259, Broadcasts: 8 64-byte pkts: 5173, Over 64-byte pkts: , Over 127-byte pkts: 172 Over 255-byte pkts: 358, Over 511-byte pkts: 3, Over 1023-byte pkts: Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 299, Broadcasts: 1014 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 3.04% of line-rate < == Output Mbits/sec, packets/sec, 0.08% of line-rate Time since last interface status change: 21:16:11 CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present 66 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
67 NOS Test Report Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:21:13 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 12544, Broadcasts: byte pkts: , Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 5, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 194, Broadcasts: 764 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.47% of line-rate Output Mbits/sec, packets/sec, 18.16% of line-rate < == Time since last interface status change: 1d02h03m CASTOR-VCS20-12# < =========== > NetApp 3170 storage array is at maximum CPU capacity. FIGURE 28 NetApp 3170 CPU Utilization All Medusa I/O traffic completed without errors. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 67
68 1.2.3 Storage Device - w/congested Fabric Storage Device - w/congested Fabric Test Objective Create network bottleneck through a single Ethernet Fabric ISL. Configure VDX switch for AUTONAS. Configure multiple 'NAS to host' data streams sufficient to saturate ISLs' available bandwidth for 30 minutes. Verify file I/O completes error-free. Add L3 FCoE and L2 Ethernet traffic to fill available bandwidth. File I/O compares are disabled. Test Configuration 1. Configure NAS auto-qos on VDX as follows: < =========== > nas auto-qos nas server-ip /32 vlan 979 < =========== > 2. Because VDX6730 does not support NAS auto-qos, move all host connections to CASTOR- VCS Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
69 NOS Test Report FIGURE 29 CASTOR-VCS20-12 Host Port Connections 3. Add IXIA connections: FIGURE 30 VCS Fabric Ports for IXIA Traffic Generator 4. Reconfigure VDX as follows: < =========== > interface TenGigabitEthernet 11/1/31 cee default no no switchport Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 69
70 NOS Test Report switchport mode access switchport access vlan 979 interface TenGigabitEthernet 12/0/31 cee default no no switchport switchport mode access switchport access vlan 979 interface TenGigabitEthernet 11/1/32 no no switchport switchport mode access switchport access vlan 979 fcoeport default interface TenGigabitEthernet 12/0/32 no no switchport switchport mode access switchport access vlan 979 fcoeport default interface TenGigabitEthernet 12/0/17 no no channel-group 201 mode active type standard interface TenGigabitEthernet 12/0/18 no no channel-group 201 mode active type standard interface Port-channel 201 switchport switchport mode access switchport access vlan 979 interface TenGigabitEthernet 12/0/19 no no channel-group 202 mode active type standard interface TenGigabitEthernet 12/0/20 no no channel-group 202 mode active type standard interface Port-channel 202 switchport switchport mode access switchport access vlan 979 interface TenGigabitEthernet 12/0/21 no no channel-group 203 mode active type standard interface TenGigabitEthernet 12/0/22 no no channel-group 203 mode active type standard 70 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
71 NOS Test Report interface Port-channel 203 switchport switchport mode access switchport access vlan 979 interface TenGigabitEthernet 12/0/23 no no channel-group 204 mode active type standard interface TenGigabitEthernet 12/0/24 no no channel-group 204 mode active type standard interface Port-channel 204 switchport switchport mode access switchport access vlan 979 interface TenGigabitEthernet 12/0/43 shutdown interface TenGigabitEthernet 12/0/44 shutdown interface TenGigabitEthernet 12/0/45 shutdown interface TenGigabitEthernet 12/0/46 shutdown interface TenGigabitEthernet 12/0/47 shutdown < =========== > Results PASS. NAS I/O completes error-free through bandwidth congestion. < =========== > CASTOR-VCS20-12# show fabric isl Rbridge-id: 12 #ISLs: 1 Src Src Nbr Nbr Index Interface Index Interface Nbr-WWN BW Trunk Nbr-Name Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 71
72 NOS Test Report Te 12/0/48 59 Te 11/1/48 10:00:00:27:F8:1C:71:48 10G Yes "M4-VCS20-11" < == CASTOR-VCS20-12# show interface tengigabitethernet 12/0/48 TenGigabitEthernet 12/0/48 is up, line protocol is up (connected) Hardware is Ethernet, address is Current address is Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:31:51 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 643, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 9, Over 511-byte pkts: 2, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 2661 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 1553, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 2457 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 91.01% of line-rate Output Mbits/sec, packets/sec, 98.17% of line-rate < == Time since last interface status change: 02:28:40 CASTOR-VCS20-12# show qos queue interface tengigabitethernet 12/0/48 Interface TenGigabitEthernet 12/0/48 RX RX TX TX CoS Packets Bytes TC Packets Bytes < == < == < == untag 0 0 untag 0 0 CASTOR-VCS20-12# show qos queue interface tengigabitethernet 12/0/31 Interface TenGigabitEthernet 12/0/31 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == CASTOR-VCS20-12# show qos queue interface tengigabitethernet 12/0/32 Interface TenGigabitEthernet 12/0/32 RX RX TX TX CoS Packets Bytes TC Packets Bytes < == untag untag CASTOR-VCS20-12# show qos queue interface port-channel Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
73 NOS Test Report Interface TenGigabitEthernet 12/0/17 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == Interface TenGigabitEthernet 12/0/18 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag CASTOR-VCS20-12# show qos queue interface port-channel 202 Interface TenGigabitEthernet 12/0/19 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag Interface TenGigabitEthernet 12/0/20 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == CASTOR-VCS20-12# show qos queue interface port-channel 203 Interface TenGigabitEthernet 12/0/21 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == Interface TenGigabitEthernet 12/0/22 RX RX TX TX CoS Packets Bytes TC Packets Bytes Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 73
74 1.2.4 Storage Device - NAS Protocol Jammer CRC Corruption on an ISL Port untag untag CASTOR-VCS20-12# show qos queue interface port-channel 204 Interface TenGigabitEthernet 12/0/23 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == Interface TenGigabitEthernet 12/0/24 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < =========== > Storage Device - NAS Protocol Jammer CRC Corruption on an ISL Port Test Objective Perform CIFS/NFS jammer testing using CRC corruption with a burst of 10 CRC errors on ISL link, in each direction sequentially, while I/O is running from a single host. Verify I/O recovers successfully. Test Configuration Shutdown all ISL interfaces on M4-VCS20-11 with the exception of one ISL to CASTOR-VCS Connect Ethernet jammer hardware in-line with remaining ISL between M4-VCS20-11 and CASTOR- VCS < =========== > interface TenGigabitEthernet 11/1/43 shutdown interface TenGigabitEthernet 11/1/44 shutdown interface TenGigabitEthernet 11/1/45 shutdown interface TenGigabitEthernet 11/1/46 shutdown interface TenGigabitEthernet 11/1/47 shutdown < =========== > Results PASS.All IO completes error-free through Ethernet jammer CRC corruption on ISL port. CIFS, CRC ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 12/0/48 TenGigabitEthernet 12/0/48 is up, line protocol is up (connected) Hardware is Ethernet, address is Current address is Pluggable media not present 74 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
75 NOS Test Report Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:45 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 6, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 11 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 34 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 28, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 31 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.36% of line-rate Output Mbits/sec, packets/sec, 10.37% of line-rate Time since last interface status change: 00:27:09 < =========== > FIGURE 31 NAS Protocol Jammer CRC Corruption on ISL Port Medusa Result 1 NFS, CRC ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 12/0/48 TenGigabitEthernet 12/0/48 is up, line protocol is up (connected) Hardware is Ethernet, address is Current address is Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:35 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 17, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 8 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 22 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 31, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 21 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.74% of line-rate Output Mbits/sec, packets/sec, 21.41% of line-rate Time since last interface status change: 00:28:50 < =========== > Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 75
76 NOS Test Report FIGURE 32 NAS Protocol Jammer CRC Corruption on ISL Port Medusa Result 2 CIFS, CRC ERROR BURST ON WRITE TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/48 TenGigabitEthernet 11/1/48 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71fd Current address is 0027.f81c.71fd Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:51 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 33, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: 33441, Over 127-byte pkts: 186 Over 255-byte pkts: 471, Over 511-byte pkts: , Over 1023-byte pkts: 1477 Over 1518-byte pkts(jumbo): Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 45 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 19, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 45 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 11.21% of line-rate Output Mbits/sec, packets/sec, 0.39% of line-rate Time since last interface status change: 00:30:48 < =========== > FIGURE 33 NAS Protocol Jammer CRC Corruption on ISL Port Medusa Result 3 NFS, CRC ERROR BURST ON WRITE TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/48 TenGigabitEthernet 11/1/48 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71fd Current address is 0027.f81c.71fd Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:01:06 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 44, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: 48643, Over 127-byte pkts: 1636 Over 255-byte pkts: 7449, Over 511-byte pkts: 13663, Over 1023-byte pkts: 9946 Over 1518-byte pkts(jumbo): Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == 76 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
77 1.2.5 Storage Device - NAS Protocol Jammer Packet Corruption on ISL Port Errors: 0, Discards: 0, TrillportCtrlFrames: 53 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 10, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 53 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 21.51% of line-rate Output Mbits/sec, packets/sec, 0.75% of line-rate Time since last interface status change: 00:33:40 < =========== > FIGURE 34 NAS Protocol Jammer CRC Corruption on ISL Port Medusa Result Storage Device - NAS Protocol Jammer Packet Corruption on ISL Port Test Objective Perform CIFS/NFS jammer testing using packet corruption with a burst of 10 packet errors on ISL link, in each direction sequentially, while I/O is running from a single host. Verify I/O recovers successfully. Test Configuration Shutdown all ISL interfaces on M4-VCS20-11 with the exception of one ISL to CASTOR-VCS Connect Ethernet jammer hardware in-line with remaining ISL between M4-VCS20-11 and CASTOR- VCS < =========== > interface TenGigabitEthernet 11/1/43 shutdown interface TenGigabitEthernet 11/1/44 shutdown interface TenGigabitEthernet 11/1/45 shutdown interface TenGigabitEthernet 11/1/46 shutdown interface TenGigabitEthernet 11/1/47 shutdown < =========== > Results PASS.All IO completes error-free through Ethernet jammer packet corruption on ISL port. CIFS, PACKET ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 12/0/48 TenGigabitEthernet 12/0/48 is up, line protocol is up (connected) Hardware is Ethernet, address is Current address is Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:44 Queueing strategy: fifo Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 77
78 NOS Test Report Receive Statistics: packets, bytes Unicasts: , Multicasts: 21, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 10 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 28 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 26, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 25 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.37% of line-rate Output Mbits/sec, packets/sec, 10.78% of line-rate Time since last interface status change: 00:38:03 < =========== > FIGURE 35 NAS Protocol Jammer Packet Corruption on ISL Port Medusa Result 1 NFS, PACKET ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 12/0/48 TenGigabitEthernet 12/0/48 is up, line protocol is up (connected) Hardware is Ethernet, address is Current address is Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:43 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 5, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 11 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 33 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 32, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 29 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.71% of line-rate Output Mbits/sec, packets/sec, 20.51% of line-rate Time since last interface status change: 00:39:4 < =========== > FIGURE 36 NAS Protocol Jammer Packet Corruption on ISL Port Medusa Result 2 78 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
79 NOS Test Report CIFS, PACKET ERROR BURST ON WRITE TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/48 TenGigabitEthernet 11/1/48 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71fd Current address is 0027.f81c.71fd Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:40 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 39, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: 26248, Over 127-byte pkts: 149 Over 255-byte pkts: 313, Over 511-byte pkts: , Over 1023-byte pkts: 1233 Over 1518-byte pkts(jumbo): Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 26 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 22, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 26 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 9.77% of line-rate Output Mbits/sec, packets/sec, 0.34% of line-rate Time since last interface status change: 00:41:19 < =========== > FIGURE 37 NAS Protocol Jammer Packet Corruption on ISL Port Medusa Result 3 NFS, PACKET ERROR BURST ON WRITE TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/48 TenGigabitEthernet 11/1/48 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71fd Current address is 0027.f81c.71fd Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:41 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 21, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: 30530, Over 127-byte pkts: 1039 Over 255-byte pkts: 4687, Over 511-byte pkts: 8996, Over 1023-byte pkts: 6391 Over 1518-byte pkts(jumbo): Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0, TrillportCtrlFrames: 28 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 21, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: 28 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 21.42% of line-rate Output Mbits/sec, packets/sec, 0.74% of line-rate Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 79
80 1.2.6 Jammer Packet Loss on an ISL Port Time since last interface status change: 00:43:00 < =========== > FIGURE 38 NAS Protocol Jammer Packet Corruption on ISL Port Medusa Result Jammer Packet Loss on an ISL Port Test Objective Perform CIFS/NFS jammer testing using packet loss with a burst of 10 packet drops on ISL link, in each direction sequentially, while I/O is running from a single host. Verify I/O recovers successfully. Test Configuration Shutdown all ISL interfaces on M4-VCS20-11 with the exception of one ISL to CASTOR-VCS Connect Ethernet jammer hardware in-line with remaining ISL between M4-VCS20-11 and CASTOR- VCS < =========== > interface TenGigabitEthernet 11/1/43 shutdown interface TenGigabitEthernet 11/1/44 shutdown interface TenGigabitEthernet 11/1/45 shutdown interface TenGigabitEthernet 11/1/46 shutdown interface TenGigabitEthernet 11/1/47 shutdown < =========== > Results PASS.All IO completes error-free through Ethernet jammer packet loss on ISL port. CIFS, PACKET DROP BURST ON READ TRAFFIC NFS, PACKET DROP BURST ON READ TRAFFIC CIFS, PACKET DROP BURST ON WRITE TRAFFIC 80 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
81 1.2.7 Storage Device - NAS Protocol Jammer CRC Corruption on Storage Port NFS, PACKET DROP BURST ON WRITE TRAFFIC Storage Device - NAS Protocol Jammer CRC Corruption on Storage Port Test Objective Perform CIFS/NFS jammer testing using CRC corruption with a burst of 10 CRC errors on storage port link, in each direction sequentially, while I/O is running from a single host. Verify I/O recovers successfully. Results PASS. All I/O completes error-free through Ethernet jammer packet corruption on storage port. CIFS, CRC ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:46 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 441, Broadcasts: byte pkts: , Over 64-byte pkts: , Over 127-byte pkts: 5 Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 3, Broadcasts: 34 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.27% of line-rate Output Mbits/sec, packets/sec, 10.95% of line-rate Time since last interface status change: 00:15:01 < =========== > Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 81
82 1.2.8 Storage Device - NAS Protocol Jammer Packet Corruption on Storage Port NFS, CRC ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:41 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 386, Broadcasts: byte pkts: 384, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 5, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 28, Broadcasts: 45 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.52% of line-rate Output Mbits/sec, packets/sec, 20.39% of line-rate Time since last interface status change: 00:17:33 < =========== > CIFS, CRC ERROR BURST ON WRITE TRAFFIC NFS, CRC ERROR BURST ON WRITE TRAFFIC Storage Device - NAS Protocol Jammer Packet Corruption on Storage Port Test Objective Perform CIFS/NFS jammer testing using packet corruption with a burst of 10 packet errors on storage port link, in each direction sequentially, while I/O is running from a single host. Verify I/O recovers successfully. 82 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
83 NOS Test Report Results PASS.All IO completes error-free through Ethernet jammer packet corruption on storage port. CIFS, PACKET ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:40 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 379, Broadcasts: 0 64-byte pkts: , Over 64-byte pkts: , Over 127-byte pkts: 4 Over 255-byte pkts: 0, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 10, Broadcasts: 26 Underruns: 0 Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.24% of line-rate Output Mbits/sec, packets/sec, 9.77% of line-rate Time since last interface status change: 00:45:43 < =========== > FIGURE 39 NAS Protocol Jammer Packet Corruption on Storage Port Medusa Result 1 NFS, PACKET ERROR BURST ON READ TRAFFIC < =========== > CASTOR-VCS20-12# show interface tengigabitethernet 11/1/4 TenGigabitEthernet 11/1/4 is up, line protocol is up (connected) Hardware is Ethernet, address is 0027.f81c.71d1 Current address is 0027.f81c.71d1 Pluggable media not present Interface index (ifindex) is MTU 2500 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 00:00:38 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 363, Broadcasts: 1 64-byte pkts: 361, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: 5, Over 511-byte pkts: 0, Over 1023-byte pkts: 0 Over 1518-byte pkts(jumbo): 0 Runts: 0, Jabbers: 0, CRC: 10, Overruns: 0 < == Errors: 0, Discards: 0 Transmit Statistics: packets, bytes Unicasts: , Multicasts: 17, Broadcasts: 29 Underruns: 0 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 83
84 1.2.9 Storage Device - NAS Protocol Jammer Packet Loss on Storage Port Errors: 0, Discards: 0 Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 0.53% of line-rate Output Mbits/sec, packets/sec, 20.75% of line-rate Time since last interface status change: 00:47:07 < =========== > FIGURE 40 NAS Protocol Jammer Packet Corruption on Storage Port Medusa Result 2 CIFS, PACKET ERROR BURST ON WRITE TRAFFIC FIGURE 41 NAS Protocol Jammer Packet Corruption on Storage Port Medusa Result 3 NFS, PACKET ERROR BURST ON WRITE TRAFFIC FIGURE 42 NAS Protocol Jammer Packet Corruption on Storage Port Medusa Result Storage Device - NAS Protocol Jammer Packet Loss on Storage Port Test Objective Perform CIFS/NFS jammer testing using packet loss with a burst of 10 lost packets on ISL link, in each direction sequentially, while I/O is running from a single host. Verify I/O recovers successfully. Results PASS.All I/O completes error-free through Ethernet jammer packet loss on storage port. CIFS, PACKET DROP BURST ON READ TRAFFIC FIGURE 43 NAS Protocol Jammer Packet Loss on Storage Port Medusa Result 1 NFS, PACKET DROP BURST ON READ TRAFFIC 84 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
85 1.3 Stress and Error Recovery FIGURE 44 NAS Protocol Jammer Packet Loss on Storage Port Medusa Result 2 CIFS, PACKET DROP BURST ON WRITE TRAFFIC FIGURE 45 NAS Protocol Jammer Packet Loss on Storage Port Medusa Result 3 NFS, PACKET DROP BURST ON WRITE TRAFFIC FIGURE 46 NAS Protocol Jammer Packet Loss on Storage Port Medusa Result Stress and Error Recovery Storage Device Fabric I/O Integrity - Congested Fabric Test Objective Configure fabric and devices for maximum link and device saturation. Configure VDX switch for AUTONAS. Add L3 FCoE traffic (COS 3), CIFS/NFS traffic (COS 2) and L2 Ethernet traffic (COS 0) to fill all available bandwidth. From all initiators, start a mixture of READ/WRITE/VERIFY traffic with random data patterns continuously to all targets for 12 hours. Verify no unexpected change in I/O throughput occurs. File I/O compares are enabled. Test Configuration See test configuration for test Results PASS. All I/O completes error-free through VCS fabric congestion. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 85
86 NOS Test Report FIGURE 47 Storage Device Fabric I/O Integrity - Congested Fabric Medusa Result - Screen 1 FIGURE 48 Storage Device Fabric I/O Integrity - Congested Fabric Medusa Result - Screen 2 < =========== > CASTOR-VCS20-12# show fabric isl Rbridge-id: 12 #ISLs: 1 Src Src Nbr Nbr Index Interface Index Interface Nbr-WWN BW Trunk Nbr-Name Te 12/0/48 59 Te 11/1/48 10:00:00:27:F8:1C:71:48 10G Yes "M4-VCS20-11" < == CASTOR-VCS20-12# show interface tengigabitethernet 12/0/48 TenGigabitEthernet 12/0/48 is up, line protocol is up (connected) Hardware is Ethernet, address is Current address is Pluggable media not present Interface index (ifindex) is MTU 9216 bytes LineSpeed Actual : Mbit LineSpeed Configured : Auto, Duplex: Full Priority Tag disable IPv6 RA Guard disable Last clearing of show interface counters: 16:20:38 Queueing strategy: fifo Receive Statistics: packets, bytes Unicasts: , Multicasts: 20085, Broadcasts: 0 64-byte pkts: 0, Over 64-byte pkts: , Over 127-byte pkts: Over 255-byte pkts: , Over 511-byte pkts: , Over 1023-byte pkts: Over 1518-byte pkts(jumbo): Runts: 0, Jabbers: 0, CRC: 0, Overruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: Transmit Statistics: packets, bytes Unicasts: , Multicasts: 48411, Broadcasts: 0 Underruns: 0 Errors: 0, Discards: 0, TrillportCtrlFrames: Rate info (interval 299 seconds): Input Mbits/sec, packets/sec, 98.15% of line-rate Output Mbits/sec, packets/sec, 97.96% of line-rate < == Time since last interface status change: 22:51:45 CASTOR-VCS20-12# show qos queue interface tengigabitethernet 12/0/48 Interface TenGigabitEthernet 12/0/48 RX RX TX TX CoS Packets Bytes TC Packets Bytes 86 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
87 NOS Test Report < == < == < == untag 0 0 untag 0 0 CASTOR-VCS20-12# show qos queue interface port-channel 201 Interface TenGigabitEthernet 12/0/17 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == Interface TenGigabitEthernet 12/0/18 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == CASTOR-VCS20-12# show qos queue interface port-channel 202 Interface TenGigabitEthernet 12/0/19 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag Interface TenGigabitEthernet 12/0/20 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == CASTOR-VCS20-12# show qos queue interface port-channel 203 Interface TenGigabitEthernet 12/0/21 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 87
88 1.3.2 Storage Device Integrity - Device Recovery from Port Toggle - Manual Cable Pull Interface TenGigabitEthernet 12/0/22 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag CASTOR-VCS20-12# show qos queue interface port-channel 204 Interface TenGigabitEthernet 12/0/23 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < == Interface TenGigabitEthernet 12/0/24 RX RX TX TX CoS Packets Bytes TC Packets Bytes untag untag < =========== > Storage Device Integrity - Device Recovery from Port Toggle - Manual Cable Pull Test Objective Perform sequentially for each Storage Device and Adapter port. With I/O running, perform a quick port toggle every Storage Device and Adapter port. Verify host I/O will recover. Results PASS. All IO recovers through port disconnections and reconnections Storage Device Integrity - Device Recovery from ISL Port Relocation Test Objective With I/O running, manually disconnect and reconnect ISL port to different port in same switch. Verify fabric integrity and file I/O recovery. Repeat test for all switch types. Results PASS. The VCS fabric reforms properly and all I/O recovers through ISL port disconnections and reconnections. 88 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
89 1.3.4 Storage Device Stress - Device Recovery from Device Port Toggle - Extended Run Storage Device Stress - Device Recovery from Device Port Toggle - Extended Run Test Objective Sequentially toggle each Initiator and Target ports in fabric. Verify host I/O will recover to alternate path and toggled path will recover. Run for 12 hours. Results PASS. All I/O recovers through all initiator and target port disable and enables. FIGURE 49 Device Port Toggle Extended Run Medusa Result - Screen 1 FIGURE 50 Device Port Toggle Extended Run Medusa Result - Screen Storage Device Recovery - ISL Port Toggle - Extended Run Test Objective Verify fabric ISL path redundancy between hosts and storage devices. Sequentially toggle each ISL path on all switches. Host I/O may pause but should recover. Verify host I/O throughout test. Run for 12 hours. Results PASS. All IO completes error-free through ISL port disable and enable commands. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 89
90 1.3.6 Storage Device Recovery - All-ISL Port Toggle FIGURE 51 ISL Port Toggle Extended Run Medusa Result - Screen 1 FIGURE 52 ISL Port Toggle Extended Run Medusa Result - Screen Storage Device Recovery - All-ISL Port Toggle Test Objective Verify fabric switch path redundancy between hosts and storage devices. Sequentially, and for all switches, disable all ISLs on the switch under test. Verify I/O pauses and resume after switch fabric convergence. Results PASS. All I/O completes error-free after ISL port disable and enable commands Storage Device Recovery - VDX 8770 Line Card Maintenance Test Objective For extended time run. Verify device connectivity to VDX 8770 blades. Sequentially power off and on each Mercury line card. Verify host I/O will failover to alternate path and toggled path will recover. Results PASS. All I/O completes error-free through line card power off and on commands. 90 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
91 1.3.8 Storage Device Recovery - Switch Offline FIGURE 53 VDX8770 Line Card Maintenance Medusa Result - Screen 1 FIGURE 54 VDX8770 Line Card Maintenance Medusa Result - Screen Storage Device Recovery - Switch Offline Test Objective Toggle each switch in sequential order. Mix of chassis disable, reboot, and power cycles. For switches containing device under test, I/O will pause and then resume after switch comes online. Results Chassis Disable/Enable: PASS. I/O successfully resumes after chassis enable. Reboot: PASS. I/O successfully resumes after chassis reboot. Power Cycle: PASS. I/O successfully resumes after chassis power cycle Storage Device Recovery - Switch Firmware download ISSU on VDX8770 Test Objective Sequentially perform firmware maintenance procedure on all VDX 8770 devices connected switches under test. Verify host I/O will continue (with minimal disruption) through firmware download. Test Configuration Execute firmwaredownload from NOS4.1.2 to NOS4.1.2aa. Results PASS. All I/O completes error-free through firmware download command. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 91
92 Workload Simulation Test Suite - Microsoft Exchange Server FIGURE 55 Switch Firmware download Medusa Result - Screen 1 FIGURE 56 Switch Firmware download Medusa Result - Screen Workload Simulation Test Suite - Microsoft Exchange Server Test Objective Validate Storage/Fabric behavior while running a Medusa Microsoft Exchange Server workload simulation test suite for 30 minutes. Verify file I/O completes error-free. File I/O compares are disabled. Results PASS. All I/O completes error-free. FIGURE 57 Microsoft Exchange Server Medusa Result - Screen 1 FIGURE 58 Microsoft Exchange Server Medusa Result - Screen 2 92 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
93 Workload Simulation Test Suite - File Server Simulation Workload Simulation Test Suite - File Server Simulation Test Objective Validate Storage/Fabric behavior while running a Medusa File Server Simulation workload simulation test suite for 30 minutes. Verify file I/O completes error-free. File I/O compares are disabled. Results PASS. All I/O completes error-free. FIGURE 59 File Server Simulation Medusa Result - Screen 1 FIGURE 60 File Server Simulation Medusa Result - Screen 2 Test Conclusions 1. Brocade VCS Fabric technology and the NetApp 3170 NAS array smoothly interoperate with both redundant and nonredundant configurations. No exceptions were noted. 2. The configuration procedures followed Brocade VCS Fabric and NetApp 3170 standard documentation guides and found no issues with these procedures. 3. All simulated changes in network and storage (add, remove, fail over) resulted in expected behavior and I/O recovery. Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 93
94 Full Network Operating System Configuration Full Network Operating System Configuration The following configuration is from a test environment and includes additional configuration beyond the scope of this rest report. Please see the "Test Configuration" and "DUT Configuration" sections of each test report to identify applicable configurations. < =========== > diag post rbridge-id 1 enable diag post rbridge-id 2 enable diag post rbridge-id 11 enable diag post rbridge-id 12 enable hardware flexport 2/0/17 type fibre-channel flexport 2/0/18 type fibre-channel flexport 2/0/19 type fibre-channel flexport 2/0/21 type fibre-channel flexport 2/0/22 type fibre-channel flexport 2/0/23 type fibre-channel flexport 12/0/17 type fibre-channel flexport 12/0/18 type fibre-channel flexport 12/0/19 type fibre-channel flexport 12/0/21 type fibre-channel flexport 12/0/22 type fibre-channel flexport 12/0/23 type fibre-channel connector-group 1/0/1 speed LowMixed connector-group 1/0/3 speed LowMixed connector-group 1/0/5 speed LowMixed connector-group 1/0/6 speed LowMixed connector-group 11/0/1 speed LowMixed connector-group 11/0/3 speed LowMixed connector-group 11/0/5 speed LowMixed connector-group 11/0/6 speed LowMixed 94 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
95 Full Network Operating System Configuration connector-group 12/0/1 speed LowMixed connector-group 12/0/3 speed LowMixed connector-group 12/0/5 speed LowMixed connector-group 12/0/6 speed LowMixed connector-group 2/0/1 speed LowMixed connector-group 2/0/3 speed LowMixed connector-group 2/0/5 speed LowMixed connector-group 2/0/6 speed LowMixed dpod 1/0/1 dpod 1/0/2 dpod 1/0/3 dpod 1/0/4 dpod 1/0/5 dpod 1/0/6 dpod 1/0/7 dpod 1/0/8 dpod 1/0/9 dpod 1/0/10 dpod 1/0/11 dpod 1/0/12 dpod 1/0/13 dpod 1/0/14 dpod 1/0/15 dpod 1/0/16 dpod 1/0/17 dpod 1/0/18 dpod 1/0/19 dpod 1/0/20 dpod 1/0/21 dpod 1/0/22 dpod 1/0/23 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 95
96 Full Network Operating System Configuration dpod 1/0/24 dpod 1/0/25 dpod 1/0/26 dpod 1/0/27 dpod 1/0/28 dpod 1/0/29 dpod 1/0/30 dpod 1/0/31 dpod 1/0/32 dpod 1/0/33 dpod 1/0/34 dpod 1/0/35 dpod 1/0/36 dpod 1/0/37 dpod 1/0/38 dpod 1/0/39 dpod 1/0/40 dpod 1/0/41 dpod 1/0/42 dpod 1/0/43 dpod 1/0/44 dpod 1/0/45 dpod 1/0/46 dpod 1/0/47 dpod 1/0/48 dpod 1/0/49 dpod 1/0/50 dpod 1/0/51 dpod 1/0/52 dpod 2/0/1 96 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
97 Full Network Operating System Configuration dpod 2/0/2 dpod 2/0/3 dpod 2/0/4 dpod 2/0/5 dpod 2/0/6 dpod 2/0/7 dpod 2/0/8 dpod 2/0/9 dpod 2/0/10 dpod 2/0/11 dpod 2/0/12 dpod 2/0/13 dpod 2/0/14 dpod 2/0/15 dpod 2/0/16 dpod 2/0/17 dpod 2/0/18 dpod 2/0/19 dpod 2/0/20 dpod 2/0/21 dpod 2/0/22 dpod 2/0/23 dpod 2/0/24 dpod 2/0/25 dpod 2/0/26 dpod 2/0/27 dpod 2/0/28 dpod 2/0/29 dpod 2/0/30 dpod 2/0/31 dpod 2/0/32 dpod 2/0/33 dpod 2/0/34 dpod 2/0/35 dpod 2/0/36 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 97
98 Full Network Operating System Configuration dpod 2/0/37 dpod 2/0/38 dpod 2/0/39 dpod 2/0/40 dpod 2/0/41 dpod 2/0/42 dpod 2/0/43 dpod 2/0/44 dpod 2/0/45 dpod 2/0/46 dpod 2/0/47 dpod 2/0/48 dpod 2/0/49 dpod 2/0/50 dpod 2/0/51 dpod 2/0/52 dpod 11/0/1 dpod 11/0/2 dpod 11/0/3 dpod 11/0/4 dpod 11/0/5 dpod 11/0/6 dpod 11/0/7 dpod 11/0/8 dpod 11/0/9 dpod 11/0/10 dpod 11/0/11 dpod 11/0/12 dpod 11/0/13 98 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
99 Full Network Operating System Configuration dpod 11/0/14 dpod 11/0/15 dpod 11/0/16 dpod 11/0/17 dpod 11/0/18 dpod 11/0/19 dpod 11/0/20 dpod 11/0/21 dpod 11/0/22 dpod 11/0/23 dpod 11/0/24 dpod 11/0/25 dpod 11/0/26 dpod 11/0/27 dpod 11/0/28 dpod 11/0/29 dpod 11/0/30 dpod 11/0/31 dpod 11/0/32 dpod 11/0/33 dpod 11/0/34 dpod 11/0/35 dpod 11/0/36 dpod 11/0/37 dpod 11/0/38 dpod 11/0/39 dpod 11/0/40 dpod 11/0/41 dpod 11/0/42 dpod 11/0/43 dpod 11/0/44 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 99
100 Full Network Operating System Configuration dpod 11/0/45 dpod 11/0/46 dpod 11/0/47 dpod 11/0/48 dpod 11/0/49 dpod 11/0/50 dpod 11/0/51 dpod 11/0/52 dpod 12/0/1 dpod 12/0/2 dpod 12/0/3 dpod 12/0/4 dpod 12/0/5 dpod 12/0/6 dpod 12/0/7 dpod 12/0/8 dpod 12/0/9 dpod 12/0/10 dpod 12/0/11 dpod 12/0/12 dpod 12/0/13 dpod 12/0/14 dpod 12/0/15 dpod 12/0/16 dpod 12/0/17 dpod 12/0/18 dpod 12/0/19 dpod 12/0/20 dpod 12/0/21 dpod 12/0/22 dpod 12/0/23 dpod 12/0/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
101 Full Network Operating System Configuration dpod 12/0/25 dpod 12/0/26 dpod 12/0/27 dpod 12/0/28 dpod 12/0/29 dpod 12/0/30 dpod 12/0/31 dpod 12/0/32 dpod 12/0/33 dpod 12/0/34 dpod 12/0/35 dpod 12/0/36 dpod 12/0/37 dpod 12/0/38 dpod 12/0/39 dpod 12/0/40 dpod 12/0/41 dpod 12/0/42 dpod 12/0/43 dpod 12/0/44 dpod 12/0/45 dpod 12/0/46 dpod 12/0/47 dpod 12/0/48 dpod 12/0/49 dpod 12/0/50 dpod 12/0/51 dpod 12/0/52 ntp server ntp server logging raslog console INFO logging syslog-server use-vrf mgmt-vrf Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 101
102 Full Network Operating System Configuration logging auditlog class SECURITY logging auditlog class CONFIGURATION logging auditlog class FIRMWARE logging syslog-facility local LOG_LOCAL7 logging syslog-client localip MM_IP switch-attributes 1 chassis-name VDX6740 host-name CASTOR-VCS20-1 switch-attributes 11 chassis-name VDX6740 host-name CASTOR-VCS20-11 switch-attributes 12 chassis-name VDX6740 host-name CASTOR-VCS20-12 switch-attributes 2 chassis-name VDX6740 host-name CASTOR-VCS20-2 no support autoupload enable support ffdc snmp-server contact "Field Support." snmp-server location "End User Premise." snmp-server sys-descr "Brocade VDX Switch." snmp-server enable trap snmp-server community ConvergedNetwork groupname user snmp-server community OrigEquipMfr groupname admin snmp-server community "Secret C0de" groupname admin snmp-server community common groupname user snmp-server community private groupname admin snmp-server community public groupname user snmp-server host public severity-level Info use-vrf mgmt-vrf snmp-server host private severity-level Info use-vrf mgmt-vrf snmp-server user snmpadmin1 groupname snmpadmin snmp-server user snmpadmin2 groupname snmpadmin snmp-server user snmpadmin3 groupname snmpadmin snmp-server user snmpuser1 groupname snmpuser snmp-server user snmpuser2 groupname snmpuser snmp-server user snmpuser3 groupname snmpuser snmp-server view All 1 included snmp-server group admin v1 read All write All notify All snmp-server group admin v2c read All write All notify All snmp-server group user v1 read All notify All snmp-server group user v2c read All notify All line vty exec-timeout 10 zoning defined-configuration cfg nos member-zone EMC_VG2_n1fc1 member-zone EMC_VG2_n2fc1 member-zone Hitachi_HNAS_n1fc1 member-zone Hitachi_HNAS_n2fc1 member-zone Hitachi_HNAS_n1fc3 member-zone Hitachi_HNAS_n2fc3 member-zone IXIA_FCoE zoning defined-configuration zone EMC_VG2_n1fc1 member-entry 50:06:01:61:3e:e0:22:af member-entry 50:06:01:68:3e:e0:22:af member-entry 50:06:01:61:47:60:30:c2 zoning defined-configuration zone EMC_VG2_n2fc1 member-entry 50:06:01:60:47:60:30:c2 member-entry 50:06:01:60:3e:e0:22:af member-entry 50:06:01:69:3e:e0:22:af zoning defined-configuration zone Hitachi_HNAS_n1fc1 member-entry 50:03:01:70:00:06:45:c1 member-entry 50:06:0e:80:13:27:3d: Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
103 Full Network Operating System Configuration zoning defined-configuration zone Hitachi_HNAS_n1fc3 member-entry 50:03:01:70:00:06:45:c3 member-entry 50:06:0e:80:13:27:3d:21 zoning defined-configuration zone Hitachi_HNAS_n2fc1 member-entry 50:06:0e:80:13:27:3d:11 member-entry 50:03:01:70:00:05:2f:e1 zoning defined-configuration zone Hitachi_HNAS_n2fc3 member-entry 50:06:0e:80:13:27:3d:21 member-entry 50:03:01:70:00:05:2f:e3 zoning defined-configuration zone IXIA_FCoE member-entry 31:00:0e:fc:00:00:00:0a member-entry 32:00:0e:fc:00:00:00:aa zoning enabled-configuration cfg-name nos zoning enabled-configuration default-zone-access allaccess zoning enabled-configuration cfg-action cfg-save role name admin desc Administrator role name user desc User aaa authentication login local aaa accounting exec default start-stop none aaa accounting commands default start-stop none service password-encryption username admin password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role admin desc Administrator username user password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role user desc User cee-map default precedence 1 priority-group-table 1 weight 40 pfc on priority-group-table 15.0 pfc off priority-group-table 15.1 pfc off priority-group-table 15.2 pfc off priority-group-table 15.3 pfc off priority-group-table 15.4 pfc off priority-group-table 15.5 pfc off priority-group-table 15.6 pfc off priority-group-table 15.7 pfc off priority-group-table 2 weight 40 pfc off priority-group-table 3 weight 20 pfc off priority-table remap fabric-priority priority 0 remap lossless-priority priority 0 nas server-ip /32 vlan 978 nas server-ip /32 vlan 978 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 fcoe fabric-map default vlan 1002 san-mode local priority 3 virtual-fabric 128 fcmap 0E:FC:00 advertisement interval 8000 keep-alive timeout interface Vlan 1 interface Vlan 864 interface Vlan 978 interface Vlan 979 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 103
104 Full Network Operating System Configuration interface Ve 978 interface Ve 979 fabric route mcast rbridge-id 1 fabric route mcast rbridge-id 2 fabric route mcast rbridge-id 11 fabric route mcast rbridge-id 12 protocol lldp advertise dcbx-fcoe-app-tlv advertise dcbx-fcoe-logical-link-tlv advertise dcbx-iscsi-app-tlv advertise dcbx-tlv advertise optional-tlv system-name system-description Brocade-VDX-VCS 20 vlan dot1q tag native port-profile UpgradedVlanProfile vlan-profile switchport switchport mode trunk switchport trunk allowed vlan all port-profile default vlan-profile switchport switchport mode trunk switchport trunk native-vlan 1 port-profile-domain default port-profile UpgradedVlanProfile class-map cee class-map default rbridge-id 1 ip route / ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-1 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default clock timezone America/Boise ag no enable 104 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
105 Full Network Operating System Configuration root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 rbridge-id 2 ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-2 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 0 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 rbridge-id 11 ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-11 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 105
106 Full Network Operating System Configuration vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 rbridge-id 12 ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-12 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default 106 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
107 Full Network Operating System Configuration clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 interface Management 1/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface Management 2/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface Management 11/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface Management 12/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface TenGigabitEthernet 1/0/1 channel-group 101 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/2 channel-group 102 mode active type standard no no Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 107
108 Full Network Operating System Configuration lacp timeout long interface TenGigabitEthernet 1/0/3 channel-group 103 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/4 channel-group 104 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 1/0/8 interface TenGigabitEthernet 1/0/9 interface TenGigabitEthernet 1/0/10 interface TenGigabitEthernet 1/0/11 interface TenGigabitEthernet 1/0/12 interface TenGigabitEthernet 1/0/13 interface TenGigabitEthernet 1/0/14 interface TenGigabitEthernet 1/0/15 interface TenGigabitEthernet 1/0/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
109 Full Network Operating System Configuration interface TenGigabitEthernet 1/0/17 interface TenGigabitEthernet 1/0/18 interface TenGigabitEthernet 1/0/19 interface TenGigabitEthernet 1/0/20 interface TenGigabitEthernet 1/0/21 interface TenGigabitEthernet 1/0/22 interface TenGigabitEthernet 1/0/23 interface TenGigabitEthernet 1/0/24 interface TenGigabitEthernet 1/0/25 interface TenGigabitEthernet 1/0/26 interface TenGigabitEthernet 1/0/27 interface TenGigabitEthernet 1/0/28 interface TenGigabitEthernet 1/0/29 interface TenGigabitEthernet 1/0/30 interface TenGigabitEthernet 1/0/31 switchport switchport mode access switchport access vlan 979 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 109
110 Full Network Operating System Configuration spanning-tree shutdown no no interface TenGigabitEthernet 1/0/32 interface TenGigabitEthernet 1/0/33 description VLAN_864_uplink switchport switchport mode access switchport access vlan 864 spanning-tree shutdown interface TenGigabitEthernet 1/0/34 interface TenGigabitEthernet 1/0/35 interface TenGigabitEthernet 1/0/36 interface TenGigabitEthernet 1/0/37 interface TenGigabitEthernet 1/0/38 interface TenGigabitEthernet 1/0/39 interface TenGigabitEthernet 1/0/40 interface TenGigabitEthernet 1/0/41 interface TenGigabitEthernet 1/0/42 interface TenGigabitEthernet 1/0/43 interface TenGigabitEthernet 1/0/44 interface TenGigabitEthernet 1/0/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
111 Full Network Operating System Configuration shutdown interface TenGigabitEthernet 1/0/46 shutdown interface TenGigabitEthernet 1/0/47 shutdown interface TenGigabitEthernet 1/0/48 shutdown interface TenGigabitEthernet 2/0/1 channel-group 101 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/2 channel-group 102 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/3 channel-group 103 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/4 channel-group 104 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 2/0/8 interface TenGigabitEthernet 2/0/9 interface TenGigabitEthernet 2/0/10 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 111
112 Full Network Operating System Configuration interface TenGigabitEthernet 2/0/11 interface TenGigabitEthernet 2/0/12 interface TenGigabitEthernet 2/0/13 interface TenGigabitEthernet 2/0/14 interface TenGigabitEthernet 2/0/15 interface TenGigabitEthernet 2/0/16 interface TenGigabitEthernet 2/0/20 interface TenGigabitEthernet 2/0/24 interface TenGigabitEthernet 2/0/25 interface TenGigabitEthernet 2/0/26 interface TenGigabitEthernet 2/0/27 interface TenGigabitEthernet 2/0/28 interface TenGigabitEthernet 2/0/29 interface TenGigabitEthernet 2/0/30 interface TenGigabitEthernet 2/0/31 interface TenGigabitEthernet 2/0/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
113 Full Network Operating System Configuration interface TenGigabitEthernet 2/0/33 interface TenGigabitEthernet 2/0/34 interface TenGigabitEthernet 2/0/35 interface TenGigabitEthernet 2/0/36 interface TenGigabitEthernet 2/0/37 interface TenGigabitEthernet 2/0/38 interface TenGigabitEthernet 2/0/39 interface TenGigabitEthernet 2/0/40 interface TenGigabitEthernet 2/0/41 interface TenGigabitEthernet 2/0/42 interface TenGigabitEthernet 2/0/43 interface TenGigabitEthernet 2/0/44 interface TenGigabitEthernet 2/0/45 shutdown interface TenGigabitEthernet 2/0/46 shutdown interface TenGigabitEthernet 2/0/47 shutdown Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 113
114 Full Network Operating System Configuration interface TenGigabitEthernet 2/0/48 shutdown interface TenGigabitEthernet 11/0/1 channel-group 11 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/2 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/3 channel-group 21 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/4 cee default switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/5 channel-group 31 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/6 channel-group 32 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/7 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/8 interface TenGigabitEthernet 11/0/9 channel-group 41 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/10 switchport switchport mode access switchport access vlan Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
115 Full Network Operating System Configuration spanning-tree shutdown interface TenGigabitEthernet 11/0/11 switchport switchport mode access switchport access vlan 978 spanning-tree shutdown interface TenGigabitEthernet 11/0/12 interface TenGigabitEthernet 11/0/13 cee default switchport switchport mode access switchport access vlan 978 spanning-tree shutdown interface TenGigabitEthernet 11/0/14 interface TenGigabitEthernet 11/0/15 switchport switchport mode access switchport access vlan 978 spanning-tree shutdown interface TenGigabitEthernet 11/0/16 channel-group 51 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/17 interface TenGigabitEthernet 11/0/18 interface TenGigabitEthernet 11/0/19 interface TenGigabitEthernet 11/0/20 interface TenGigabitEthernet 11/0/21 interface TenGigabitEthernet 11/0/22 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 115
116 Full Network Operating System Configuration interface TenGigabitEthernet 11/0/23 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/24 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/25 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/26 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/27 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/28 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/29 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/30 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/31 cee default switchport switchport mode access 116 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
117 Full Network Operating System Configuration switchport access vlan 979 spanning-tree shutdown interface TenGigabitEthernet 11/0/32 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown fcoeport default interface TenGigabitEthernet 11/0/33 channel-group 33 mode on type standard interface TenGigabitEthernet 11/0/34 interface TenGigabitEthernet 11/0/35 interface TenGigabitEthernet 11/0/36 interface TenGigabitEthernet 11/0/37 channel-group 1 mode on type standard no no interface TenGigabitEthernet 11/0/38 interface TenGigabitEthernet 11/0/39 interface TenGigabitEthernet 11/0/40 interface TenGigabitEthernet 11/0/41 interface TenGigabitEthernet 11/0/42 interface TenGigabitEthernet 11/0/43 interface TenGigabitEthernet 11/0/44 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 117
118 Full Network Operating System Configuration interface TenGigabitEthernet 11/0/45 interface TenGigabitEthernet 11/0/46 interface TenGigabitEthernet 11/0/47 interface TenGigabitEthernet 11/0/48 interface TenGigabitEthernet 12/0/1 channel-group 11 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/2 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/3 channel-group 21 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/4 interface TenGigabitEthernet 12/0/5 channel-group 31 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/6 channel-group 32 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/7 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/8 interface TenGigabitEthernet 12/0/9 channel-group 41 mode active type standard 118 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
119 Full Network Operating System Configuration no no lacp timeout long interface TenGigabitEthernet 12/0/10 interface TenGigabitEthernet 12/0/11 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/12 interface TenGigabitEthernet 12/0/13 cee default switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/14 interface TenGigabitEthernet 12/0/15 switchport switchport mode access switchport access vlan 978 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/16 channel-group 51 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/20 interface TenGigabitEthernet 12/0/24 interface TenGigabitEthernet 12/0/25 interface TenGigabitEthernet 12/0/26 interface TenGigabitEthernet 12/0/27 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 119
120 Full Network Operating System Configuration interface TenGigabitEthernet 12/0/28 interface TenGigabitEthernet 12/0/29 interface TenGigabitEthernet 12/0/30 interface TenGigabitEthernet 12/0/31 cee default switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/32 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no fcoeport default interface TenGigabitEthernet 12/0/33 channel-group 33 mode on type standard no no interface TenGigabitEthernet 12/0/34 no no interface TenGigabitEthernet 12/0/35 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/36 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown no no interface TenGigabitEthernet 12/0/37 channel-group 1 mode on type standard no no interface TenGigabitEthernet 12/0/38 interface TenGigabitEthernet 12/0/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
121 Full Network Operating System Configuration interface TenGigabitEthernet 12/0/40 interface TenGigabitEthernet 12/0/41 interface TenGigabitEthernet 12/0/42 interface TenGigabitEthernet 12/0/43 interface TenGigabitEthernet 12/0/44 interface TenGigabitEthernet 12/0/45 interface TenGigabitEthernet 12/0/46 interface TenGigabitEthernet 12/0/47 interface TenGigabitEthernet 12/0/48 interface FortyGigabitEthernet 1/0/49 interface FortyGigabitEthernet 1/0/50 interface FortyGigabitEthernet 1/0/51 interface FortyGigabitEthernet 1/0/52 interface FortyGigabitEthernet 2/0/49 interface FortyGigabitEthernet 2/0/50 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 121
122 Full Network Operating System Configuration interface FortyGigabitEthernet 2/0/51 interface FortyGigabitEthernet 2/0/52 no interface FortyGigabitEthernet 11/0/49 interface FortyGigabitEthernet 11/0/50 interface FortyGigabitEthernet 11/0/51 interface FortyGigabitEthernet 11/0/52 interface FortyGigabitEthernet 12/0/49 interface FortyGigabitEthernet 12/0/50 interface FortyGigabitEthernet 12/0/51 interface FortyGigabitEthernet 12/0/52 interface Port-channel 1 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 11 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 21 cee default vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 31 vlag ignore-split 122 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
123 Full Network Operating System Configuration mtu 9216 switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 32 vlag ignore-split mtu 9216 switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 33 no vlag ignore-split mtu 9216 switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 41 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 51 vlag ignore-split switchport switchport mode access switchport access vlan 979 spanning-tree shutdown interface Port-channel 101 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 102 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 103 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 104 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 123
124 Full Network Operating System Configuration interface Port-channel 105 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add 864, switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 106 vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add 864, switchport trunk tag native-vlan spanning-tree shutdown interface Port-channel 107 no vlag ignore-split switchport switchport mode trunk switchport trunk allowed vlan add switchport trunk tag native-vlan spanning-tree shutdown interface FibreChannel 2/0/17 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/18 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/19 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/21 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/22 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/23 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/17 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/18 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/19 no isl-r_rdy 124 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
125 Full Network Operating System Configuration trunk-enable fec-enable interface FibreChannel 12/0/21 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/22 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/23 no isl-r_rdy trunk-enable fec-enable interface Fcoe 1/1/1 interface Fcoe 1/1/2 interface Fcoe 1/1/3 interface Fcoe 1/1/4 interface Fcoe 1/1/5 interface Fcoe 1/1/6 interface Fcoe 1/1/7 interface Fcoe 1/1/8 interface Fcoe 1/1/9 interface Fcoe 1/1/10 interface Fcoe 1/1/11 interface Fcoe 1/1/12 interface Fcoe 1/1/13 interface Fcoe 1/1/14 interface Fcoe 1/1/15 interface Fcoe 1/1/16 interface Fcoe 1/1/17 interface Fcoe 1/1/18 interface Fcoe 1/1/19 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 125
126 Full Network Operating System Configuration interface Fcoe 1/1/20 interface Fcoe 1/1/21 interface Fcoe 1/1/22 interface Fcoe 1/1/23 interface Fcoe 1/1/24 interface Fcoe 1/1/25 interface Fcoe 1/1/26 interface Fcoe 1/1/27 interface Fcoe 1/1/28 interface Fcoe 1/1/29 interface Fcoe 1/1/30 interface Fcoe 1/1/31 interface Fcoe 1/1/32 interface Fcoe 1/1/33 interface Fcoe 1/1/34 interface Fcoe 1/1/35 interface Fcoe 1/1/36 interface Fcoe 1/1/37 interface Fcoe 1/1/38 interface Fcoe 1/1/39 interface Fcoe 1/1/40 interface Fcoe 1/1/41 interface Fcoe 1/1/42 interface Fcoe 1/1/43 interface Fcoe 1/1/44 interface Fcoe 1/1/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
127 Full Network Operating System Configuration interface Fcoe 1/1/46 interface Fcoe 1/1/47 interface Fcoe 1/1/48 interface Fcoe 1/1/49 interface Fcoe 1/1/50 interface Fcoe 1/1/51 interface Fcoe 1/1/52 interface Fcoe 1/1/53 interface Fcoe 1/1/54 interface Fcoe 1/1/55 interface Fcoe 1/1/56 interface Fcoe 1/1/57 interface Fcoe 1/1/58 interface Fcoe 1/1/59 interface Fcoe 1/1/60 interface Fcoe 1/1/61 interface Fcoe 1/1/62 interface Fcoe 1/1/63 interface Fcoe 1/1/64 interface Fcoe 1/2/1 interface Fcoe 1/2/2 interface Fcoe 1/2/3 interface Fcoe 1/2/4 interface Fcoe 1/2/5 interface Fcoe 1/2/6 interface Fcoe 1/2/7 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 127
128 Full Network Operating System Configuration interface Fcoe 1/2/8 interface Fcoe 1/2/9 interface Fcoe 1/2/10 interface Fcoe 1/2/11 interface Fcoe 1/2/12 interface Fcoe 1/2/13 interface Fcoe 1/2/14 interface Fcoe 1/2/15 interface Fcoe 1/2/16 interface Fcoe 1/2/17 interface Fcoe 1/2/18 interface Fcoe 1/2/19 interface Fcoe 1/2/20 interface Fcoe 1/2/21 interface Fcoe 1/2/22 interface Fcoe 1/2/23 interface Fcoe 1/2/24 interface Fcoe 1/2/25 interface Fcoe 1/2/26 interface Fcoe 1/2/27 interface Fcoe 1/2/28 interface Fcoe 1/2/29 interface Fcoe 1/2/30 interface Fcoe 1/2/31 interface Fcoe 1/2/32 interface Fcoe 1/2/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
129 Full Network Operating System Configuration interface Fcoe 1/2/34 interface Fcoe 1/2/35 interface Fcoe 1/2/36 interface Fcoe 1/2/37 interface Fcoe 1/2/38 interface Fcoe 1/2/39 interface Fcoe 1/2/40 interface Fcoe 1/2/41 interface Fcoe 1/2/42 interface Fcoe 1/2/43 interface Fcoe 1/2/44 interface Fcoe 1/2/45 interface Fcoe 1/2/46 interface Fcoe 1/2/47 interface Fcoe 1/2/48 interface Fcoe 1/2/49 interface Fcoe 1/2/50 interface Fcoe 1/2/51 interface Fcoe 1/2/52 interface Fcoe 1/2/53 interface Fcoe 1/2/54 interface Fcoe 1/2/55 interface Fcoe 1/2/56 interface Fcoe 1/2/57 interface Fcoe 1/2/58 interface Fcoe 1/2/59 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 129
130 Full Network Operating System Configuration interface Fcoe 1/2/60 interface Fcoe 1/2/61 interface Fcoe 1/2/62 interface Fcoe 1/2/63 interface Fcoe 1/2/64 interface Fcoe 1/11/1 interface Fcoe 1/11/2 interface Fcoe 1/11/3 interface Fcoe 1/11/4 interface Fcoe 1/11/5 interface Fcoe 1/11/6 interface Fcoe 1/11/7 interface Fcoe 1/11/8 interface Fcoe 1/11/9 interface Fcoe 1/11/10 interface Fcoe 1/11/11 interface Fcoe 1/11/12 interface Fcoe 1/11/13 interface Fcoe 1/11/14 interface Fcoe 1/11/15 interface Fcoe 1/11/16 interface Fcoe 1/11/17 interface Fcoe 1/11/18 interface Fcoe 1/11/19 interface Fcoe 1/11/20 interface Fcoe 1/11/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
131 Full Network Operating System Configuration interface Fcoe 1/11/22 interface Fcoe 1/11/23 interface Fcoe 1/11/24 interface Fcoe 1/11/25 interface Fcoe 1/11/26 interface Fcoe 1/11/27 interface Fcoe 1/11/28 interface Fcoe 1/11/29 interface Fcoe 1/11/30 interface Fcoe 1/11/31 interface Fcoe 1/11/32 interface Fcoe 1/11/33 interface Fcoe 1/11/34 interface Fcoe 1/11/35 interface Fcoe 1/11/36 interface Fcoe 1/11/37 interface Fcoe 1/11/38 interface Fcoe 1/11/39 interface Fcoe 1/11/40 interface Fcoe 1/11/41 interface Fcoe 1/11/42 interface Fcoe 1/11/43 interface Fcoe 1/11/44 interface Fcoe 1/11/45 interface Fcoe 1/11/46 interface Fcoe 1/11/47 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 131
132 Full Network Operating System Configuration interface Fcoe 1/11/48 interface Fcoe 1/11/49 interface Fcoe 1/11/50 interface Fcoe 1/11/51 interface Fcoe 1/11/52 interface Fcoe 1/11/53 interface Fcoe 1/11/54 interface Fcoe 1/11/55 interface Fcoe 1/11/56 interface Fcoe 1/11/57 interface Fcoe 1/11/58 interface Fcoe 1/11/59 interface Fcoe 1/11/60 interface Fcoe 1/11/61 interface Fcoe 1/11/62 interface Fcoe 1/11/63 interface Fcoe 1/11/64 interface Fcoe 1/12/1 interface Fcoe 1/12/2 interface Fcoe 1/12/3 interface Fcoe 1/12/4 interface Fcoe 1/12/5 interface Fcoe 1/12/6 interface Fcoe 1/12/7 interface Fcoe 1/12/8 interface Fcoe 1/12/9 132 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
133 Full Network Operating System Configuration interface Fcoe 1/12/10 interface Fcoe 1/12/11 interface Fcoe 1/12/12 interface Fcoe 1/12/13 interface Fcoe 1/12/14 interface Fcoe 1/12/15 interface Fcoe 1/12/16 interface Fcoe 1/12/17 interface Fcoe 1/12/18 interface Fcoe 1/12/19 interface Fcoe 1/12/20 interface Fcoe 1/12/21 interface Fcoe 1/12/22 interface Fcoe 1/12/23 interface Fcoe 1/12/24 interface Fcoe 1/12/25 interface Fcoe 1/12/26 interface Fcoe 1/12/27 interface Fcoe 1/12/28 interface Fcoe 1/12/29 interface Fcoe 1/12/30 interface Fcoe 1/12/31 interface Fcoe 1/12/32 interface Fcoe 1/12/33 interface Fcoe 1/12/34 interface Fcoe 1/12/35 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 133
134 Full Network Operating System Configuration interface Fcoe 1/12/36 interface Fcoe 1/12/37 interface Fcoe 1/12/38 interface Fcoe 1/12/39 interface Fcoe 1/12/40 interface Fcoe 1/12/41 interface Fcoe 1/12/42 interface Fcoe 1/12/43 interface Fcoe 1/12/44 interface Fcoe 1/12/45 interface Fcoe 1/12/46 interface Fcoe 1/12/47 interface Fcoe 1/12/48 interface Fcoe 1/12/49 interface Fcoe 1/12/50 interface Fcoe 1/12/51 interface Fcoe 1/12/52 interface Fcoe 1/12/53 interface Fcoe 1/12/54 interface Fcoe 1/12/55 interface Fcoe 1/12/56 interface Fcoe 1/12/57 interface Fcoe 1/12/58 interface Fcoe 1/12/59 interface Fcoe 1/12/60 interface Fcoe 1/12/ Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report
135 Full Network Operating System Configuration interface Fcoe 1/12/62 interface Fcoe 1/12/63 interface Fcoe 1/12/64 < =========== > Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report 135
Brocade VCS Fabric Technology with the EMC VNX5300
Junet 2015 Brocade VCS Fabric Technology with the EMC VNX5300 Test Report Supporting Network OS 6.0.1 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the
Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array
October 2015 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report Supporting Network OS 6.0.1 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX,
Nutanix Hyperconverged Appliance with the Brocade VDX ToR Switch Deployment Guide
January 8, 2016 Nutanix Hyperconverged Appliance with the Brocade VDX ToR Switch Deployment Guide 2016 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol,
Brocade Solution for EMC VSPEX Server Virtualization
Reference Architecture Brocade Solution Blueprint Brocade Solution for EMC VSPEX Server Virtualization Microsoft Hyper-V for 50 & 100 Virtual Machines Enabled by Microsoft Hyper-V, Brocade ICX series switch,
Brocade One Data Center Cloud-Optimized Networks
POSITION PAPER Brocade One Data Center Cloud-Optimized Networks Brocade s vision, captured in the Brocade One strategy, is a smooth transition to a world where information and applications reside anywhere
Brocade Network Advisor High Availability Using Microsoft Cluster Service
Brocade Network Advisor High Availability Using Microsoft Cluster Service This paper discusses how installing Brocade Network Advisor on a pair of Microsoft Cluster Service nodes provides automatic failover
Brocade VCS Fabric Technology and NAS with NFS Validation Test
Brocade VCS Fabric Technology and NAS with NFS Validation Test NetApp/VMware vsphere 5.0 Red Hat Enterprise Linux This material outlines sample configurations and associated test results of Brocade VCS
How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine
Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest
ADVANCED NETWORK CONFIGURATION GUIDE
White Paper ADVANCED NETWORK CONFIGURATION GUIDE CONTENTS Introduction 1 Terminology 1 VLAN configuration 2 NIC Bonding configuration 3 Jumbo frame configuration 4 Other I/O high availability options 4
Virtual Connect Enterprise Manager Server Guide
53-1004163-02 06 May 2016 Virtual Connect Enterprise Manager Server Guide Supporting Network Advisor 14.0.1 Copyright 2016 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade
Fibre Channel over Ethernet: Enabling Server I/O Consolidation
WHITE PAPER Fibre Channel over Ethernet: Enabling Server I/O Consolidation Brocade is delivering industry-leading oe solutions for the data center with CNAs, top-of-rack switches, and end-of-row oe blades
Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study
White Paper Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study 2012 Cisco and/or its affiliates. All rights reserved. This
Ethernet Fabrics: An Architecture for Cloud Networking
WHITE PAPER www.brocade.com Data Center Ethernet Fabrics: An Architecture for Cloud Networking As data centers evolve to a world where information and applications can move anywhere in the cloud, classic
Brocade Fabric Vision Technology Frequently Asked Questions
Brocade Fabric Vision Technology Frequently Asked Questions Introduction This document answers frequently asked questions about Brocade Fabric Vision technology. For more information about Fabric Vision
DATA CENTER. Best Practices for High Availability Deployment for the Brocade ADX Switch
DATA CENTER Best Practices for High Availability Deployment for the Brocade ADX Switch CONTENTS Contents... 2 Executive Summary... 3 Introduction... 3 Brocade ADX HA Overview... 3 Hot-Standby HA... 4 Active-Standby
Brocade Network Advisor: CLI Configuration Manager
Brocade Network Advisor: CLI Configuration Manager Brocade Network Advisor is a unified network management platform to manage the entire Brocade network, including both SAN and IP products. This technical
DEDICATED NETWORKS FOR IP STORAGE
DEDICATED NETWORKS FOR IP STORAGE ABSTRACT This white paper examines EMC and VMware best practices for deploying dedicated IP storage networks in medium to large-scale data centers. In addition, it explores
VCS Monitoring and Troubleshooting Using Brocade Network Advisor
VCS Monitoring and Troubleshooting Using Brocade Network Advisor Brocade Network Advisor is a unified network management platform to manage the entire Brocade network, including both SAN and IP products.
vsphere Networking vsphere 5.5 ESXi 5.5 vcenter Server 5.5 EN-001074-02
vsphere 5.5 ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more
Nutanix Tech Note. VMware vsphere Networking on Nutanix
Nutanix Tech Note VMware vsphere Networking on Nutanix Nutanix Virtual Computing Platform is engineered from the ground up for virtualization and cloud environments. This Tech Note describes vsphere networking
Brocade SAN Scalability Guidelines: Brocade Fabric OS v7.x
Brocade SAN Scalability Guidelines: Brocade Fabric OS v7.x Version 7.2, update 1 Dated: February 5, 2014 This document provides scalability guidelines that can be used to design and deploy extremely stable
Demartek June 2012. Broadcom FCoE/iSCSI and IP Networking Adapter Evaluation. Introduction. Evaluation Environment
June 212 FCoE/iSCSI and IP Networking Adapter Evaluation Evaluation report prepared under contract with Corporation Introduction Enterprises are moving towards 1 Gigabit networking infrastructures and
Brocade Virtual Traffic Manager and Microsoft IIS Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Microsoft IIS Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX,
Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version
Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version Topology Objective Background Configure EtherChannel. Four switches have just been installed. The distribution layer switches are Catalyst
HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios
HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios Part number 603028-003 Third edition August 2010 Copyright 2009,2010 Hewlett-Packard Development Company, L.P.
Cloud Optimized Performance: I/O-Intensive Workloads Using Flash-Based Storage
WHITE PAPER Cloud Optimized Performance: I/O-Intensive Workloads Using Flash-Based Storage Brocade continues to innovate by delivering the industry s first 16 Gbps switches for low latency and high transaction
vsphere Networking vsphere 6.0 ESXi 6.0 vcenter Server 6.0 EN-001391-01
vsphere 6.0 ESXi 6.0 vcenter Server 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more
Where IT perceptions are reality. Test Report. OCe14000 Performance. Featuring Emulex OCe14102 Network Adapters Emulex XE100 Offload Engine
Where IT perceptions are reality Test Report OCe14000 Performance Featuring Emulex OCe14102 Network Adapters Emulex XE100 Offload Engine Document # TEST2014001 v9, October 2014 Copyright 2014 IT Brand
Scalable Approaches for Multitenant Cloud Data Centers
WHITE PAPER www.brocade.com DATA CENTER Scalable Approaches for Multitenant Cloud Data Centers Brocade VCS Fabric technology is the ideal Ethernet infrastructure for cloud computing. It is manageable,
Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide
Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2015 A Dell Deployment and Configuration Guide Revisions Date February 2013 October 2013 March 2014
Multitenancy Options in Brocade VCS Fabrics
WHITE PAPER DATA CENTER Multitenancy Options in Brocade VCS Fabrics As cloud environments reach mainstream adoption, achieving scalable network segmentation takes on new urgency to support multitenancy.
The functionality and advantages of a high-availability file server system
The functionality and advantages of a high-availability file server system This paper discusses the benefits of deploying a JMR SHARE High-Availability File Server System. Hardware and performance considerations
Interoperability Test Results for Juniper Networks EX Series Ethernet Switches and NetApp Storage Systems
APPLICATION NOTE Network Attached Storage Interoperability Testing Interoperability Test Results for Juniper Networks EX Series Ethernet Switches and Storage Systems Copyright 2012, Juniper Networks, Inc.
Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches
Migration Guide Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide November 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is
N5 NETWORKING BEST PRACTICES
N5 NETWORKING BEST PRACTICES Table of Contents Nexgen N5 Networking... 2 Overview of Storage Networking Best Practices... 2 Recommended Switch features for an iscsi Network... 2 Setting up the iscsi Network
VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS
VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS Successfully configure all solution components Use VMS at the required bandwidth for NAS storage Meet the bandwidth demands of a 2,200
Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over)
Extreme Networks White Paper Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over) The evolution of the data center fabric has been well documented. The
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell
Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters
Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters Emulex OneConnect Ethernet Network Adapters Introduction This document gives an overview of how to
How To Evaluate Netapp Ethernet Storage System For A Test Drive
Performance evaluation sponsored by NetApp, Inc. Introduction Ethernet storage is advancing towards a converged storage network, supporting the traditional NFS, CIFS and iscsi storage protocols and adding
Building Tomorrow s Data Center Network Today
WHITE PAPER www.brocade.com IP Network Building Tomorrow s Data Center Network Today offers data center network solutions that provide open choice and high efficiency at a low total cost of ownership,
Backup and Recovery with Cisco UCS Solutions for SAP HANA
Configuration Guide Backup and Recovery with Cisco UCS Solutions for SAP HANA Configuration Guide March, 2014 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page
Windows Server 2008 R2 Hyper-V Server and Windows Server 8 Beta Hyper-V
Features Comparison: Hyper-V Server and Hyper-V February 2012 The information contained in this document relates to a pre-release product which may be substantially modified before it is commercially released.
Multi-Chassis Trunking for Resilient and High-Performance Network Architectures
WHITE PAPER www.brocade.com IP Network Multi-Chassis Trunking for Resilient and High-Performance Network Architectures Multi-Chassis Trunking is a key Brocade technology in the Brocade One architecture
A Principled Technologies white paper commissioned by Dell Inc.
A Principled Technologies white paper commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Summary... 3 Features of Simple Switch Mode... 3 Sample scenarios... 5 Testing scenarios... 6 Scenario
BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012
BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012 2013 Brocade Communications Corporate Headquarters - San Jose, CA USA T: (408) 333-8000 [email protected] European Headquarters
Windows Host Utilities 6.0.2 Installation and Setup Guide
Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
The Business Case for Software-Defined Networking
WHITE PAPER The Business Case for Software-Defined Networking Brocade enables customers a means of reducing costs of service delivery through Software-Defined Networking (SDN) technologies. In addition,
Private cloud computing advances
Building robust private cloud services infrastructures By Brian Gautreau and Gong Wang Private clouds optimize utilization and management of IT resources to heighten availability. Microsoft Private Cloud
Brocade 5600 vrouter License and Entitlement Management
13 November 2015 Brocade 5600 vrouter License and Entitlement Management Reference Guide Supporting Brocade 5600 vrouter 4.0R1 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade,
ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK
ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK KEY FEATURES PROVISION FROM BARE- METAL TO PRODUCTION QUICKLY AND EFFICIENTLY Controlled discovery with active control of your hardware Automatically
Network configuration for the IBM PureFlex System
Network configuration for the IBM PureFlex System Note: The initial configuration of your IBM PureFlex System will be performed by IBM services that are included with your purchase. To ensure their success,
Introduction to MPIO, MCS, Trunking, and LACP
Introduction to MPIO, MCS, Trunking, and LACP Sam Lee Version 1.0 (JAN, 2010) - 1 - QSAN Technology, Inc. http://www.qsantechnology.com White Paper# QWP201002-P210C lntroduction Many users confuse the
Brocade Virtual Traffic Manager and Microsoft Outlook Web Access Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Microsoft Outlook Web Access Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing
Using Virtual Switches in PowerVM to Drive Maximum Value of 10 Gb Ethernet
Using Virtual Switches in PowerVM to Drive Maximum Value of 10 Gb Ethernet by Glenn E. Miller Certified IT Specialist Power Systems, AIX and PowerHA IBM Corporation and Kris Speetjens IT Architect Nobius
Fibre Channel over Ethernet in the Data Center: An Introduction
Fibre Channel over Ethernet in the Data Center: An Introduction Introduction Fibre Channel over Ethernet (FCoE) is a newly proposed standard that is being developed by INCITS T11. The FCoE protocol specification
BROCADE FABRIC VISION TECHNOLOGY FREQUENTLY ASKED QUESTIONS
FAQ BROCADE FABRIC VISION TECHNOLOGY FREQUENTLY ASKED QUESTIONS Introduction This document answers frequently asked questions about Brocade Fabric Vision technology. For more information about Fabric Vision
Data Center Convergence. Ahmad Zamer, Brocade
Ahmad Zamer, Brocade SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and individual members may use this material in presentations
Feature Comparison. Windows Server 2008 R2 Hyper-V and Windows Server 2012 Hyper-V
Comparison and Contents Introduction... 4 More Secure Multitenancy... 5 Flexible Infrastructure... 9 Scale, Performance, and Density... 13 High Availability... 18 Processor and Memory Support... 24 Network...
Fiber Channel Over Ethernet (FCoE)
Fiber Channel Over Ethernet (FCoE) Using Intel Ethernet Switch Family White Paper November, 2008 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing
Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference
Dell EqualLogic Best Practices Series Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference Storage Infrastructure and Solutions Engineering Dell Product Group
Managing Microsoft Hyper-V Server 2008 R2 with HP Insight Management
Managing Microsoft Hyper-V Server 2008 R2 with HP Insight Management Integration note, 4th Edition Introduction... 2 Overview... 2 Comparing Insight Management software Hyper-V R2 and VMware ESX management...
vrealize Operations Manager Customization and Administration Guide
vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.0.1 This document supports the version of each product listed and supports all subsequent versions until
Brocade Fabric OS DATA CENTER. Target Path Selection Guide. 53-1003916-03 January 4, 2016
January 4, 2016 DATA CENTER Brocade Fabric OS Target Path Selection Guide Brocade Fabric OS (Brocade FOS) Target Path releases are recommended code levels for Brocade Fibre Channel switch platforms. Use
Deploying Brocade VDX 6720 Data Center Switches with Brocade VCS in Enterprise Data Centers
WHITE PAPER www.brocade.com Data Center Deploying Brocade VDX 6720 Data Center Switches with Brocade VCS in Enterprise Data Centers At the heart of Brocade VDX 6720 switches is Brocade Virtual Cluster
SPEED your path to virtualization.
SPEED your path to virtualization. 2011 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice Introducing HP VirtualSystem Chief pillar of
Data Center Evolution without Revolution
WHITE PAPER www.brocade.com DATA CENTER Data Center Evolution without Revolution Brocade networking solutions help organizations transition smoothly to a world where information and applications can reside
An Oracle White Paper October 2013. How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches
An Oracle White Paper October 2013 How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches Introduction... 1 Exadata Database Machine X3-2 Full Rack Configuration... 1 Multirack
How To Write An Article On An Hp Appsystem For Spera Hana
Technical white paper HP AppSystem for SAP HANA Distributed architecture with 3PAR StoreServ 7400 storage Table of contents Executive summary... 2 Introduction... 2 Appliance components... 3 3PAR StoreServ
Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router iscsi Appliance
Enhancing the Dell iscsi SAN with Dell PowerVault TM Tape Libraries and Chelsio Unified Storage Router April 12, 2012 Table of Contents 1.0 Introduction... 4 2.0 Chelsio Unified Storage Router (USR) SAS-to-...
VMware Virtual SAN 6.2 Network Design Guide
VMware Virtual SAN 6.2 Network Design Guide TECHNICAL WHITE PAPER APRIL 2016 Contents Intended Audience... 2 Overview... 2 Virtual SAN Network... 2 Physical network infrastructure... 3 Data center network...
Isilon IQ Network Configuration Guide
Isilon IQ Network Configuration Guide An Isilon Systems Best Practice Paper August 2008 ISILON SYSTEMS Table of Contents Cluster Networking Introduction...3 Assumptions...3 Cluster Networking Features...3
Brocade Virtual Traffic Manager and Magento Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Magento Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric
Setup Cisco Call Manager on VMware
created by: Rainer Bemsel Version 1.0 Dated: July/09/2011 The purpose of this document is to provide the necessary steps to setup a Cisco Call Manager to run on VMware. I ve been researching for a while
RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES
RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS: COMPETITIVE FEATURES RED HAT ENTERPRISE VIRTUALIZATION FOR SERVERS Server virtualization offers tremendous benefits for enterprise IT organizations server
Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices
Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices A Dell Technical White Paper Dell Symantec THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND
FIBRE CHANNEL OVER ETHERNET
FIBRE CHANNEL OVER ETHERNET A Review of FCoE Today ABSTRACT Fibre Channel over Ethernet (FcoE) is a storage networking option, based on industry standards. This white paper provides an overview of FCoE,
HP ProLiant Cluster for MSA1000 for Small Business... 2. Hardware Cabling Scheme... 3. Introduction... 3. Software and Hardware Requirements...
Installation Checklist HP ProLiant Cluster for HP StorageWorks Modular Smart Array1000 for Small Business using Microsoft Windows Server 2003 Enterprise Edition November 2004 Table of Contents HP ProLiant
SAN Implementation Course SANIW; 3 Days, Instructor-led
SAN Implementation Course SANIW; 3 Days, Instructor-led Course Description In this workshop course, you learn how to connect Windows, vsphere, and Linux hosts via Fibre Channel (FC) and iscsi protocols
Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters
Brocade and EMC Solution for Microsoft Hyper-V and SharePoint Clusters Highlights a Brocade-EMC solution with EMC CLARiiON, EMC Atmos, Brocade Fibre Channel (FC) switches, Brocade FC HBAs, and Brocade
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
VLAN for DekTec Network Adapters
Application Note DT-AN-IP-2 VLAN for DekTec Network Adapters 1. Introduction VLAN (Virtual LAN) is a technology to segment a single physical network into multiple independent virtual networks. The VLANs
Windows Host Utilities 6.0 Installation and Setup Guide
Windows Host Utilities 6.0 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 4-NETAPP
Evaluation of Enterprise Data Protection using SEP Software
Test Validation Test Validation - SEP sesam Enterprise Backup Software Evaluation of Enterprise Data Protection using SEP Software Author:... Enabling you to make the best technology decisions Backup &
Deployment Guide. How to prepare your environment for an OnApp Cloud deployment.
Deployment Guide How to prepare your environment for an OnApp Cloud deployment. Document version 1.07 Document release date 28 th November 2011 document revisions 1 Contents 1. Overview... 3 2. Network
Continuous Data Protection. PowerVault DL Backup to Disk Appliance
Continuous Data Protection PowerVault DL Backup to Disk Appliance Continuous Data Protection Current Situation The PowerVault DL Backup to Disk Appliance Powered by Symantec Backup Exec offers the industry
CCNA R&S: Introduction to Networks. Chapter 5: Ethernet
CCNA R&S: Introduction to Networks Chapter 5: Ethernet 5.0.1.1 Introduction The OSI physical layer provides the means to transport the bits that make up a data link layer frame across the network media.
The Road to SDN: Software-Based Networking and Security from Brocade
WHITE PAPER www.brocade.com SOFTWARE NETWORKING The Road to SDN: Software-Based Networking and Security from Brocade Software-Defined Networking (SDN) presents a new approach to rapidly introducing network
FOR SERVERS 2.2: FEATURE matrix
RED hat ENTERPRISE VIRTUALIZATION FOR SERVERS 2.2: FEATURE matrix Red hat enterprise virtualization for servers Server virtualization offers tremendous benefits for enterprise IT organizations server consolidation,
Veeam Cloud Connect. Version 8.0. Administrator Guide
Veeam Cloud Connect Version 8.0 Administrator Guide April, 2015 2015 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may be
Ethernet Storage Best Practices
Technical Report Ethernet Storage Best Practices David Klem, Trey Layton, Frank Pleshe, NetApp January 2010 TR-3802 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 USING VLANS FOR TRAFFIC SEPARATION... 3 2.1 VLAN
The Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer
The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration
VMware Virtual SAN Network Design Guide TECHNICAL WHITE PAPER
TECHNICAL WHITE PAPER Table of Contents Intended Audience.... 3 Overview.... 3 Virtual SAN Network... 3 Physical Network Infrastructure... 4 Data Center Network... 4 Host Network Adapter.... 5 Virtual
Configuring IPS High Bandwidth Using EtherChannel Load Balancing
Configuring IPS High Bandwidth Using EtherChannel Load Balancing This guide helps you to understand and deploy the high bandwidth features available with IPS v5.1 when used in conjunction with the EtherChannel
Data Center Networking Designing Today s Data Center
Data Center Networking Designing Today s Data Center There is nothing more important than our customers. Data Center Networking Designing Today s Data Center Executive Summary Demand for application availability
Remote PC Guide Series - Volume 1
Introduction and Planning for Remote PC Implementation with NETLAB+ Document Version: 2016-02-01 What is a remote PC and how does it work with NETLAB+? This educational guide will introduce the concepts
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.0 July 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing Disaster Recovery Version 7.0 July