Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array
|
|
|
- Osborne Daniel
- 10 years ago
- Views:
Transcription
1 October 2015 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report Supporting Network OS 6.0.1
2 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, HyperEdge, ICX, MLX, MyBrocade, OpenScript, The Effortless Network, VCS, VDX, Vplane, and Vyatta are registered trademarks, and Fabric Vision and vadx are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of others. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade s the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. assume no liability or responsibility to any person or entity with respect to the accuracy of this document or any loss, cost, liability, or damages arising from the information contained herein or the computer programs that accompany it. The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit
3 Contents Preface... 5 Overview... 5 Purpose of This Document...5 Audience... 5 Objectives... 5 Document History...6 About Brocade... 6 About EMC...6 Configure DUT and Test Equipment...7 Task 1. Brocade VDX Switch Configuration Logical Chassis Mode...7 Task 2. EMC Isilon Configuration...7 Task 3. Windows Host Configuration Task 4. Red Hat Linux Host Configuration...15 Task 5. Medusa I/O Generation Configuration...15 Network OS Test Report Test Plan Scope Test Configuration...18 DUT Descriptions DUT Specifications...20 DUT Configuration Related Documents...24 Test Cases Base Functionality Advanced Functionality Stress and Error Recovery Brocade Network Advisor...34 Test Conclusions...36 Full Brocade Network OS Configuration Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 3
4 4 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
5 Preface Overview... 5 Purpose of This Document...5 Audience... 5 Objectives... 5 Document History...6 About Brocade... 6 About EMC...6 Overview Many data centers use network attached storage (NAS) for a variety of applications and workloads. As more data is stored on NAS, efficient network designs are under evaluation to minimize latency, to maximize the use of interswitch links between switches, and to automate network configuration changes. For these reasons, Brocade VCS Fabric technology with Brocade VDX switches is increasingly being deployed when new NAS arrays are added to the storage pool. Purpose of This Document The goal of this document is to validate Brocade VCS Fabric technology with the EMC Isilon NAS storage array. The testing includes cases that demonstrate VCS Fabric feature support, high availability and resiliency, and automatic network reconfiguration when links are added or removed. This document provides validation test results for typical use cases of NAS with Brocade VCS Fabric technology and EMC Isilon NAS storage arrays. Audience This document is written for a technical audience, including solution architects, system engineers, and technical development representatives. Objectives 1. Validate interoperability with redundant and nonredundant network topologies with Brocade VCS Fabric technology and EMC Isilon. 2. Identify any unique configuration details necessary to establish end-to-end connectivity. 3. Simulate real-world customer environment perturbation and validate end-to-end behavior and recovery. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 5
6 Document History Document History Date Version Description Initial version Updated the initial configuration in the "Configure DUT and Test Equipment" section. Added "Full Network Operating System Configuration" section. About Brocade Brocade networking solutions empower the world's leading organizations to transition smoothly to a world where applications and information reside anywhere. By delivering agility and innovation for cloud-based environments, Brocade helps organizations modernize their networks and accelerate their journey to the New IP. In particular, Brocade solutions for storage networking, data center routing, software-defined networking (SDN), and network functions virtualization (NFV) empower organizations to capitalize on the unique business opportunities driven by virtualization and the cloud. To deliver a best-in-class solution, Brocade partners with world-class IT companies around the globe About EMC EMC offers data storage, information security, virtualization, analytics, cloud computing, and other products and services that enable businesses to store, manage, protect, and analyze data. 6 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
7 Configure DUT and Test Equipment Task 1. Brocade VDX Switch Configuration Logical Chassis Mode...7 Task 2. EMC Isilon Configuration...7 Task 3. Windows Host Configuration Task 4. Red Hat Linux Host Configuration...15 Task 5. Medusa I/O Generation Configuration...15 This section describes the initial configuration of devices under test (DUTs)and test equipment. In some test cases, additional configuration changes are made. Task 1. Brocade VDX Switch Configuration Logical Chassis Mode On the VCS cluster, configure VLAN 979 interfaces on all cluster members. Configure the VLAG interfaces connecting to Windows and Red Hat hosts as well as the NAS storage array. NOTE See the "DUT Configuration" section of each validation test report for applicable configuration commands. Task 2. EMC Isilon Configuration This section describes the EMC Isilon and share configurations. NOTE Screen captures are from OneFS and are also applicable to OneFS Physical Interface Configuration Configure an EMC Isilon subnet and include all interfaces that connect to the VCS cluster. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 7
8 Configure DUT and Test Equipment FIGURE 1 EMC Isilon Physical Interface Configuration 2. SMB Share Configuration Configure an EMC Isilon Windows share (SMB) and allow full access. 8 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
9 Configure DUT and Test Equipment FIGURE 2 EMC Isilon SMB Share Configuration 3. NFS Share Configuration Configure an EMC Isilon UNIX share (NFS) and allow full access. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 9
10 Task 3. Windows Host Configuration FIGURE 3 EMC Isilon NFS Share Configuration Task 3. Windows Host Configuration Configuring and mapping windows hosts for the VCS cluster. 1. Configure Windows 2012 Server Hosts for Ethernet Teaming Configure the Windows 2012 Server NIC teaming interface for connectivity to the VCS cluster. 10 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
11 Configure DUT and Test Equipment FIGURE 4 Windows 2012 NIC Teaming 2. Configure Windows 2008 Server Hosts for Ethernet Teaming Configure the Windows 2008 Server NIC teaming interface for connectivity to the VCS cluster using the Brocade Host Connectivity Manager. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 11
12 Configure DUT and Test Equipment FIGURE 5 Windows 2008 NIC Team Using the Brocade Host Connectivity Manager 3. Map EMC Isilon Network Shares on Windows 2012 Server Map network drives on Windows 2012 Server hosts. 12 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
13 Configure DUT and Test Equipment FIGURE 6 Windows 2012 NIC Team Configuration Screen 1 FIGURE 7 Windows 2012 NIC Team Configuration Screen 2 4. Map Network Drives on the Windows 2008 Server Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 13
14 Configure DUT and Test Equipment Map network drives on Windows 2008 Server hosts. FIGURE 8 Windows 2008 Network Drive Mapping Screen 1 FIGURE 9 Windows 2008 Network Drive Mapping Screen 2 14 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
15 Task 4. Red Hat Linux Host Configuration Task 4. Red Hat Linux Host Configuration This task describes configuring NIC bonding and mounting shares on Red Hat Linux. 1. Configure NIC Bonding The following are the entries within /etc/sysconfig/network-scripts/ on Red Hat hosts to enable Ethernet bonding, or NIC bonding. < =========== > ifcfg-eth4 DEVICE=eth4 BOOTPROTO=none ONBOOT=yes MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED=no ifcfg-eth5 DEVICE=eth4 BOOTPROTO=none ONBOOT=yes MASTER=bond0 SLAVE=yes USERCTL=no NM_CONTROLLED=no ifcfg-bond0 DEVICE=bond0 IPADDR= NETMASK= ONBOOT=yes BOOTPROTO=none USERCTL=no NM_CONTROLLED=no BONDING_OPTS="mode=802.3ad miimon=100 downdelay=5000 updelay=5000" < =========== > 2. Mount NFS Disk Shares The following commands mount EMC VNX VG2 NFS shares on hosts that are running Red Hat 6.5 or 6.3. < =========== > mount -t nfs :/ifs/data/NFS_ROBERT/REDHAT_ /mnt/isilon mount -t nfs :/ifs/data/NFS_ROBERT/REDHAT_ /mnt/isilon < =========== > Task 5. Medusa I/O Generation Configuration The following shows the configuration of the Medusa I/O data patterns used in the test cases. 1. Standard I/O with 64KB Blocks For test scenarios using standard I/O (64-KB testing size), configure Medusa for the following command line result: < =========== > pain 1600MB -b64kb -v180 -H1 -l35 -Y1 -M180 < =========== > 2. Maximum I/O with 1-MB Blocks Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 15
16 Configure DUT and Test Equipment For test scenarios using maximum bandwidth I/O (1-MB testing size), configure Medusa for the following command line result: < =========== > maim 1600MB -b1mb -Q8 -n -u -q5 -w -o -Y1 -M180 --perf-mode < =========== > 3. Microsoft Exchange Server I/O For test scenarios using Microsoft Exchange Server Simulation (Medusa preconfigured Storage Simulation test), configure Medusa for the following command line result: < =========== > maim 1600MB -Q1 -n -u -q5 -o -l69 -Y1 -M180 < =========== > 4. File Server I/O For test scenarios using File Server Simulation (Medusa preconfigured Storage Simulation test), configure Medusa for the following command line result: < =========== > maim 1600MB - -%2:r50@8KB,w50@8KB - -%10:r80@64KB,w20@64KB -Q1 -n -u -o -l69 -Y1 -M180 < =========== > 16 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
17 Network OS Test Report Test Plan Related Documents...24 Test Cases Test Conclusions...36 Test Plan Scope The storage array is connected to one Brocade VDX Ethernet fabric with multiple server hosts to drive I/O. Testing is performed with the Brocade Network OS in a heterogeneous environment. Test beds include Brocade switches configured in routed and nonrouted fabric configurations. Testing is centered on interoperability and optimal configuration. Performance is observed within the context of best-practice fabric configuration; however, absolute maximum benchmark reporting of storage performance is beyond the scope of this test. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 17
18 Test Configuration Test Configuration FIGURE 10 Test Topology The following figure shows VCS Fabric switch port connections and vlag (port-channel) ports for each server and the EMC Isilon NAS Storage Array. For example, 1/0/1 means that the device port connects to RBridge# = 1, Card# = 0, and Port# = 1. For fixed top-of-rack switches such as the Brocade VDX 6720, 6730, and 6740, there are no port cards, which is indicated by 0 for the Card#. 18 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
19 DUT Descriptions FIGURE 11 Device to VCS Fabric Switch Port Connections DUT Descriptions The following tables provide details about the devices under test (DUTs). TABLE 1 Storage Array Model Vendor Description Isilon X200 EMC Network attached storage (NAS) array TABLE 2 Switches Model Vendor Description Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 19
20 DUT Specifications TABLE 2 Switches (Continued) BR-VDX6740 Brocade The Brocade VDX 6740 and 6740T are Ethernet fabric top-of-rack (ToR) switches featuring 10-GbE ports with 40-GbE uplinks. The Brocade VDX 6740T-1G Switch offers dual-speed functionality. It can be deployed with 1000BASE-T for existing 1-GbE server connectivity and can be upgraded via software to 10GBASE-T for future bandwidth growth. Together with Brocade VCS Fabric technology, these switches deliver the high performance and low latency needed to support demanding virtualized data center environments. DUT Specifications NAS Array Version EMC Isilon OneFS Brocade Switches Device ID Version VDX 6740 CASTOR-VCS20-1 Network OS VDX 6740 CASTOR-VCS20-2 Network OS VDX 6740 CASTOR-VCS20-11 Network OS VDX 6740 CASTOR-VCS20-12 Network OS Adapters Version Brocade (Red Hat Enterprise Linux 6.6) Brocade (Windows Server 2008) Brocade (ESXi 5.5u2) Emulex OCe (Windows Server 2012) Servers Memory Processor IBM x3650 M3 8 GB 2.13 GHz IBM x3650 M3 32 GB 2.13 GHz HP ProLiant DL380 G7 8 GB 2.13 GHz HP ProLiant DL380 G7 8 GB 2.13 GHz Cisco UCS B200 M3 (x4) 64 GB 2.10 GHz (x2) 20 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
21 DUT Configuration Operating Systems ESXi ESXi Guests Version 5.5u2 (x2) Windows Server 2012 R2 (x2), Red Hat Enterprise Linux 6.6, Red Hat Enterprise Linux 7.0, SUSE Linux Enterprise Server 11.3 Red Hat Enterprise Linux Server 6.6, 7.0 SUSE Linux Enterprise Server 11.3 Windows Server 2008 R2, 2012 R2 (x2) Test Equipment Version Medusa Labs Test Tools Device Interface IP Address EMC Isilon node3, 10gige EMC Isilon node2, 10gige-agg Windows 2012 Server NIC Team Windows 2008 Server NIC Team Red Hat 6.6 Server bond Windows 2012 Server Cisco VIC Ethernet Red Hat 7.0 Server Cisco VIC enp8s SUSE Linux Server Cisco VIC eth ESXi 5.5u2 Server Cisco VIC vswitch ESXi 5.5u2 Server vswitch DUT Configuration < ========== > interface Vlan 979 rbridge-id 1 interface Ve 979 ip address /16 rbridge-id 2 interface Ve 979 ip address /16 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 21
22 Network OS Test Report rbridge-id 11 interface Ve 979 ip address /16 rbridge-id 12 interface Ve 979 ip address /16 interface TenGigabitEthernet 1/0/1 no no channel-group 101 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/2 no no channel-group 102 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/3 no no channel-group 103 mode active type standard lacp timeout long interface TenGigabitEthernet 1/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 2/0/1 no no channel-group 101 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/2 no no channel-group 102 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/3 no no channel-group 103 mode active type standard lacp timeout long interface TenGigabitEthernet 2/0/5 channel-group 105 mode active type standard 22 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
23 Network OS Test Report no no lacp timeout long interface TenGigabitEthernet 2/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 11/0/1 no no channel-group 11 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/2 no no mode access access vlan 979 interface TenGigabitEthernet 12/0/1 no no channel-group 11 mode active type standard lacp timeout long interface Port-channel 11 vlag ignore-split mode access access vlan 979 interface Port-channel 101 vlag ignore-split mode access access vlan 979 interface Port-channel 102 vlag ignore-split mode access access vlan 979 interface Port-channel 103 vlag ignore-split mode access access vlan 979 interface Port-channel 105 vlag ignore-split mode trunk trunk allowed vlan add 979 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 23
24 Related Documents trunk tag native-vlan interface Port-channel 106 vlag ignore-split mode trunk trunk allowed vlan add 979 trunk tag native-vlan interface Port-channel 107 no vlag ignore-split mode trunk trunk allowed vlan add 979 trunk tag native-vlan < ========== > Related Documents Brocade Network OS Administrator's Guide, v6.0.1 EMC OneFS Web Administration Guide (login required) EMC OneFS CLI Administration Guide (login required) Test Cases The following test cases are designed to verify both basic and advanced functionality features between the Brocade VCS cluster and both host and storage devices; to stress all devices; and to confirm successful error recovery. 1.1 Base Functionality Physical Connection and Speed Negotiation Storage Connectivity Virtual LAG Connectivity 1.2 Advanced Functionality MTU Jumbo Frame Maximum Bandwidth Congested Fabric with Auto-NAS Jammer CRC Corruption on an ISL Port 24 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
25 1.1 Base Functionality Jammer Packet Corruption on an ISL Port Jammer Packet Loss on an ISL Port Jammer CRC Corruption on a Storage Port Jammer Packet Corruption on a Storage Port Jammer Packet Loss on a Storage Port ISL Congestion and Interface Buffer Queue Depth 1.3 Stress and Error Recovery Congested Fabric with Auto-NAS Extended Run Manual Cable Pull ISL Port Relocation Device Port Toggle Extended Run ISL Port Toggle Extended Run Split Brain Recovery Brocade VDX 8770 Line Card Maintenance Extended Run Switch Offline Workload Simulation Microsoft Exchange Server Workload Simulation File Server Host-side Interface Port Toggle Storage-side Interface Port Toggle Storage Failover 1.4 Brocade Network Advisor Ethernet Fabric Discovery Ethernet Fabric Addition and Removal Ethernet Fabric Configuration Backup and Restoration Ethernet Fabric Firmware Download 1.1 Base Functionality Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 25
26 1.1.1 Physical Connection and Speed Negotiation Physical Connection and Speed Negotiation Test Objective Test storage device connectivity to a Brocade VDX switch with supported speed and duplex settings. Validation Verify that Brocade VDX console output shows expected speed and duplex settings for all connected physical interfaces. Verify that the storage device console or GUI output shows expected speed and duplex settings for all connected physical interfaces. Results PASS. All interfaces are up and operational at expected speed settings. Brocade VDX show interface commands reflect the expected interface speed Storage Connectivity Test Objective Test end-to-end connectivity between hosts and the storage device. Validation Verify that hosts can mount shares on the storage device. Results PASS. All NAS targets on Windows, Red Hat, and ESXi hosts are successfully connected Virtual LAG Connectivity Test Objective Test whether Brocade VCS vlag connectivity can be established with both hosts and storage devices. Validation All host and storage link aggregation ports sync with Brocade VCS vlag ports. Results PASS. All port-channel interfaces are operational and in sync. 1.2 Advanced Functionality 26 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
27 1.2.1 MTU Jumbo Frame MTU Jumbo Frame Test Objective Test the largest MTU supported by all devices in the I/O path. Validation All I/O runs error-free at the maximum frame size for a minimum of 15 minutes. Results PASS. All nonfragmented ping packets are successfully responded to, and all jumbo frame storage traffic completes error-free Maximum Bandwidth Test Objective Test host-to-storage traffic using an I/O generator configured for maximum throughput. Validation All I/O runs error-free at the maximum throughput for a minimum of 15 minutes. Results PASS. All I/O completes error-free. All host and storage ports show bandwidth under maximum capacity Congested Fabric with Auto-NAS Test Objective Test host-to-storage traffic using an I/O generator configured for maximum throughput while configured with Brocade VCS Auto-NAS enabled and additional Layer 3 FCoE and Layer 2 Ethernet traffic to congest the ISL links. Validation All storage I/O runs error-free at the maximum throughput for a minimum of 15 minutes. Background traffic can experience congestion errors. Results PASS. NAS I/O completes error-free during bandwidth congestion. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 27
28 1.2.4 Jammer CRC Corruption on an ISL Port Jammer CRC Corruption on an ISL Port Test Objective Verify whether end-to-end storage traffic can be maintained during a short burst of CRC packet corruptions on an ISL port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer CRC corruption on the ISL port Jammer Packet Corruption on an ISL Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet corruptions on an ISL port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet corruption on the ISL port Jammer Packet Loss on an ISL Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet loss on an ISL port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet loss on the ISL port. 28 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
29 1.2.7 Jammer CRC Corruption on a Storage Port Jammer CRC Corruption on a Storage Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of CRC packet corruptions on a storage port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet corruption on the storage port Jammer Packet Corruption on a Storage Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet corruptions on a storage port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet corruption on the storage port Jammer Packet Loss on a Storage Port Test Objective Verify that end-to-end storage traffic can be maintained during a short burst of packet loss on a storage port. Validation All I/O runs error-free throughout the packet jammer trigger. Results PASS. All I/O completes error-free during Ethernet jammer packet loss on the storage port. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 29
30 ISL Congestion and Interface Buffer Queue Depth ISL Congestion and Interface Buffer Queue Depth Test Objective Verify increasing ISL interface buffer queues in an ISL congestion scenario, eliminating tail-end packet drops and improving throughput. Validation 1. Disable as many ISLs as necessary to force end-to-end IP storage traffic through a single ISL. 2. Initiate multiple host read I/O traffic streams that produce consistent TX packet drops, and observe packet drops on the many-to-one ISL interface queue and average throughput over a 30-minute period. 3. Increase ISL interface buffer queue depth above default values, and repeat multiple host read I/O traffic steams. Results PASS. Average I/O throughput increases when transmit queue buffers are increased, and packet drops are reduced. 1.3 Stress and Error Recovery Congested Fabric with Auto-NAS Extended Run Test Objective Test host-to-storage traffic using an I/O generator configured for maximum throughput while configured with Brocade VCS Auto-NAS enabled and additional Layer 3 FCoE and Layer 2 Ethernet traffic to congest the ISL links over a 12-hour period. Validation All storage I/O runs error-free at the maximum throughput for a minimum of 12 hours. Background traffic can experience congestion errors. Results PASS. All I/O completes error-free during VCS Fabric congestion Manual Cable Pull Test Objective Test that host-to-storage traffic can maintain I/O during a quick port toggle on every storage and host port. 30 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
31 1.3.3 ISL Port Relocation Validation All storage I/O runs error-free during each rapid port toggle. Results PASS. All I/O recovers during port disconnections and reconnections ISL Port Relocation Test Objective Test that host-to-storage traffic can maintain I/O during ISL relocation within the same switch on all VCS nodes. Validation All storage I/O runs error-free during each ISL port relocation. Results PASS. The VCS Fabric reforms properly, and all I/O recovers during ISL port disconnections and reconnections Device Port Toggle Extended Run Test Objective Test that host-to-storage traffic can maintain I/O during sequential host and storage port disabling and enabling over a 12-hour period. Validation All storage I/O runs error-free during host and storage port disable and enable actions for a minimum of 12 hours. Results PASS. All I/O recovers during all initiator and target port disabling and enabling ISL Port Toggle Extended Run Test Objective Test that host-to-storage traffic can maintain I/O during ISL port disabling and enabling over a 12-hour period. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 31
32 1.3.6 Split Brain Recovery Validation All storage I/O runs error-free during ISL port disable and enable actions for a minimum of 12 hours. Results PASS. All I/O completes error-free after ISL port disable and enable commands Split Brain Recovery Test Objective Test that host-to-storage traffic can recover while disabling and enabling all ISL ports sequentially on each switch in the VCS cluster. Validation 1. Disable all ISL ports on a single switch, and wait for the VCS cluster to segment. 2. Enable all ISL ports on the same switch, and wait for the VCS cluster to reform. 3. Repeat for each switch in the VCS cluster. Results PASS. All I/O recovers after ISL port disable and enable commands Brocade VDX 8770 Line Card Maintenance Extended Run Test Objective Test that host-to-storage traffic can be maintained during line-card power-off and power-on commands sequentially on each Brocade VDX 8770 line card in the VCS cluster. Validation All storage I/O runs error-free during power-off and power-on actions for a minimum of 12 hours. Results N/A. The Brocade VDX 8770 is not present in the network configuration Switch Offline Test Objective Test that host-to-storage traffic can be maintained during chassis disable and enable commands, switch reloads, and chassis power cycles sequentially on each VDX in the VCS cluster. 32 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
33 1.3.9 Workload Simulation Microsoft Exchange Server Validation All storage I/O runs error-free during chassis disable and enable commands, switch reloads, and chassis power cycles. Results Chassis Disable/Enable: PASS. I/O successfully resumes after the chassis is enabled. Reboot: PASS. I/O successfully resumes after the chassis is rebooted. Power Cycle: PASS. I/O successfully resumes after the chassis is power-cycled Workload Simulation Microsoft Exchange Server Test Objective Test host-to-storage traffic using the Medusa Microsoft Exchange Server workload simulation suite. Validation All storage I/O runs error-free for a minimum of 30 minutes. Results PASS. All I/O completes error-free Workload Simulation File Server Test Objective Test host-to-storage traffic using the Medusa File Server workload simulation suite. Validation All storage I/O runs error-free for a minimum of 30 minutes. Results PASS. All I/O completes error-free Host-side Interface Port Toggle Test Objective Test that host-to-storage traffic can be maintained while sequentially disabling and enabling connections to the VCS cluster from the host side. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 33
34 Storage-side Interface Port Toggle Validation All storage I/O runs error-free during host-side interface disable and enable actions. Results PASS. All I/O completes error-free during host-side interface disable and enable actions Storage-side Interface Port Toggle Test Objective Test that host-to-storage traffic can be maintained while sequentially disabling and enabling connections to the VCS cluster from the storage side. Validation All storage I/O runs error-free during storage-side interface disable and enable actions. Results PASS. All I/O completes error-free during storage-side interface disable and enable actions Storage Failover Test Objective Test that storage node redundancy failover occurs within the expected storage node feature set. Validation All storage I/O runs error-free during storage failover (if lossless failover is supported) or traffic successfully resumes after storage failover is complete (if lossless failover is not supported). Results PASS. I/O successfully resumes after node reboot. 1.4 Brocade Network Advisor Ethernet Fabric Discovery Test Objective Test that the Brocade Network Advisor discovers the Ethernet fabric. 34 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
35 1.4.2 Ethernet Fabric Addition and Removal Validation Brocade Network Advisor successfully discovers the VCS cluster. Results PASS. The VCS cluster is successfully discovered Ethernet Fabric Addition and Removal Test Objective Test the addition and removal of Brocade Network Advisor Ethernet fabric nodes. Validation Brocade Network Advisor successfully tracks VCS node addition and removal. Results PASS. Brocade Network Advisor accurately reports the VCS cluster changes during removal and addition Ethernet Fabric Configuration Backup and Restoration Test Objective Test that Brocade Network Advisor backs up and restores the Ethernet fabric configuration. Validation Brocade Network Advisor successfully performs configuration backup and restoration. Results PASS. Brocade Network Advisor successfully performs configuration backup and restoration Ethernet Fabric Firmware Download Test Objective Test downloading the Brocade Network Advisor Ethernet fabric firmware. Validation Brocade Network Advisor successfully downloads firmware to all VCS cluster nodes. Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 35
36 Test Conclusions Results PASS. Brocade Network Advisor successfully performs firmware download to Network OS Test Conclusions 1. Brocade VCS Fabric technology and the EMC Isilon NAS array smoothly interoperate with both redundant and nonredundant configurations. No exceptions were noted. 2. The configuration procedures followed Brocade VCS Fabric technology and EMC Isilon standard documentation guides and found no issues with these procedures. 3. All simulated changes in network and storage (add, remove, fail over) resulted in expected behavior and I/O recovery. 36 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
37 This section contains the Network Operating System test environment configuration. NOTE The following configuration is from a test environment and includes additional configuration beyond the scope of this test report. Please see the "Test Configuration" and "DUT Configuration" sections of each test report to identify applicable configurations. < =========== > diag post rbridge-id 1 enable diag post rbridge-id 2 enable diag post rbridge-id 11 enable diag post rbridge-id 12 enable hardware flexport 2/0/17 type fibre-channel flexport 2/0/18 type fibre-channel flexport 2/0/19 type fibre-channel flexport 2/0/21 type fibre-channel flexport 2/0/22 type fibre-channel flexport 2/0/23 type fibre-channel flexport 12/0/17 type fibre-channel flexport 12/0/18 type fibre-channel flexport 12/0/19 type fibre-channel flexport 12/0/21 type fibre-channel flexport 12/0/22 type fibre-channel flexport 12/0/23 type fibre-channel connector-group 1/0/1 speed LowMixed connector-group 1/0/3 speed LowMixed connector-group 1/0/5 speed LowMixed connector-group 1/0/6 speed LowMixed connector-group 11/0/1 speed LowMixed connector-group 11/0/3 speed LowMixed connector-group 11/0/5 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 37
38 speed LowMixed connector-group 11/0/6 speed LowMixed connector-group 12/0/1 speed LowMixed connector-group 12/0/3 speed LowMixed connector-group 12/0/5 speed LowMixed connector-group 12/0/6 speed LowMixed connector-group 2/0/1 speed LowMixed connector-group 2/0/3 speed LowMixed connector-group 2/0/5 speed LowMixed connector-group 2/0/6 speed LowMixed dpod 1/0/1 dpod 1/0/2 dpod 1/0/3 dpod 1/0/4 dpod 1/0/5 dpod 1/0/6 dpod 1/0/7 dpod 1/0/8 dpod 1/0/9 dpod 1/0/10 dpod 1/0/11 dpod 1/0/12 dpod 1/0/13 dpod 1/0/14 dpod 1/0/15 dpod 1/0/16 dpod 1/0/17 dpod 1/0/18 dpod 1/0/19 dpod 1/0/20 dpod 1/0/21 38 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
39 dpod 1/0/22 dpod 1/0/23 dpod 1/0/24 dpod 1/0/25 dpod 1/0/26 dpod 1/0/27 dpod 1/0/28 dpod 1/0/29 dpod 1/0/30 dpod 1/0/31 dpod 1/0/32 dpod 1/0/33 dpod 1/0/34 dpod 1/0/35 dpod 1/0/36 dpod 1/0/37 dpod 1/0/38 dpod 1/0/39 dpod 1/0/40 dpod 1/0/41 dpod 1/0/42 dpod 1/0/43 dpod 1/0/44 dpod 1/0/45 dpod 1/0/46 dpod 1/0/47 dpod 1/0/48 dpod 1/0/49 dpod 1/0/50 dpod 1/0/51 dpod 1/0/52 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 39
40 dpod 2/0/1 dpod 2/0/2 dpod 2/0/3 dpod 2/0/4 dpod 2/0/5 dpod 2/0/6 dpod 2/0/7 dpod 2/0/8 dpod 2/0/9 dpod 2/0/10 dpod 2/0/11 dpod 2/0/12 dpod 2/0/13 dpod 2/0/14 dpod 2/0/15 dpod 2/0/16 dpod 2/0/17 dpod 2/0/18 dpod 2/0/19 dpod 2/0/20 dpod 2/0/21 dpod 2/0/22 dpod 2/0/23 dpod 2/0/24 dpod 2/0/25 dpod 2/0/26 dpod 2/0/27 dpod 2/0/28 dpod 2/0/29 dpod 2/0/30 dpod 2/0/31 dpod 2/0/32 dpod 2/0/33 dpod 2/0/34 40 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
41 dpod 2/0/35 dpod 2/0/36 dpod 2/0/37 dpod 2/0/38 dpod 2/0/39 dpod 2/0/40 dpod 2/0/41 dpod 2/0/42 dpod 2/0/43 dpod 2/0/44 dpod 2/0/45 dpod 2/0/46 dpod 2/0/47 dpod 2/0/48 dpod 2/0/49 dpod 2/0/50 dpod 2/0/51 dpod 2/0/52 dpod 11/0/1 dpod 11/0/2 dpod 11/0/3 dpod 11/0/4 dpod 11/0/5 dpod 11/0/6 dpod 11/0/7 dpod 11/0/8 dpod 11/0/9 dpod 11/0/10 dpod 11/0/11 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 41
42 dpod 11/0/12 dpod 11/0/13 dpod 11/0/14 dpod 11/0/15 dpod 11/0/16 dpod 11/0/17 dpod 11/0/18 dpod 11/0/19 dpod 11/0/20 dpod 11/0/21 dpod 11/0/22 dpod 11/0/23 dpod 11/0/24 dpod 11/0/25 dpod 11/0/26 dpod 11/0/27 dpod 11/0/28 dpod 11/0/29 dpod 11/0/30 dpod 11/0/31 dpod 11/0/32 dpod 11/0/33 dpod 11/0/34 dpod 11/0/35 dpod 11/0/36 dpod 11/0/37 dpod 11/0/38 dpod 11/0/39 dpod 11/0/40 dpod 11/0/41 dpod 11/0/42 42 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
43 dpod 11/0/43 dpod 11/0/44 dpod 11/0/45 dpod 11/0/46 dpod 11/0/47 dpod 11/0/48 dpod 11/0/49 dpod 11/0/50 dpod 11/0/51 dpod 11/0/52 dpod 12/0/1 dpod 12/0/2 dpod 12/0/3 dpod 12/0/4 dpod 12/0/5 dpod 12/0/6 dpod 12/0/7 dpod 12/0/8 dpod 12/0/9 dpod 12/0/10 dpod 12/0/11 dpod 12/0/12 dpod 12/0/13 dpod 12/0/14 dpod 12/0/15 dpod 12/0/16 dpod 12/0/17 dpod 12/0/18 dpod 12/0/19 dpod 12/0/20 dpod 12/0/21 dpod 12/0/22 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 43
44 dpod 12/0/23 dpod 12/0/24 dpod 12/0/25 dpod 12/0/26 dpod 12/0/27 dpod 12/0/28 dpod 12/0/29 dpod 12/0/30 dpod 12/0/31 dpod 12/0/32 dpod 12/0/33 dpod 12/0/34 dpod 12/0/35 dpod 12/0/36 dpod 12/0/37 dpod 12/0/38 dpod 12/0/39 dpod 12/0/40 dpod 12/0/41 dpod 12/0/42 dpod 12/0/43 dpod 12/0/44 dpod 12/0/45 dpod 12/0/46 dpod 12/0/47 dpod 12/0/48 dpod 12/0/49 dpod 12/0/50 dpod 12/0/51 dpod 12/0/52 44 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
45 ntp server ntp server logging raslog console INFO logging syslog-server use-vrf mgmt-vrf logging auditlog class SECURITY logging auditlog class CONFIGURATION logging auditlog class FIRMWARE logging syslog-facility local LOG_LOCAL7 logging syslog-client localip MM_IP switch-attributes 1 chassis-name VDX6740 host-name CASTOR-VCS20-1 switch-attributes 11 chassis-name VDX6740 host-name CASTOR-VCS20-11 switch-attributes 12 chassis-name VDX6740 host-name CASTOR-VCS20-12 switch-attributes 2 chassis-name VDX6740 host-name CASTOR-VCS20-2 no support autoupload enable support ffdc snmp-server contact "Field Support." snmp-server location "End User Premise." snmp-server sys-descr "Brocade VDX Switch." snmp-server enable trap snmp-server community ConvergedNetwork groupname user snmp-server community OrigEquipMfr groupname admin snmp-server community "Secret C0de" groupname admin snmp-server community common groupname user snmp-server community private groupname admin snmp-server community public groupname user snmp-server host public severity-level Info use-vrf mgmt-vrf snmp-server host private severity-level Info use-vrf mgmt-vrf snmp-server user snmpadmin1 groupname snmpadmin snmp-server user snmpadmin2 groupname snmpadmin snmp-server user snmpadmin3 groupname snmpadmin snmp-server user snmpuser1 groupname snmpuser snmp-server user snmpuser2 groupname snmpuser snmp-server user snmpuser3 groupname snmpuser snmp-server view All 1 included snmp-server group admin v1 read All write All notify All snmp-server group admin v2c read All write All notify All snmp-server group user v1 read All notify All snmp-server group user v2c read All notify All line vty exec-timeout 10 zoning defined-configuration cfg nos member-zone EMC_VG2_n1fc1 member-zone EMC_VG2_n2fc1 member-zone Hitachi_HNAS_n1fc1 member-zone Hitachi_HNAS_n2fc1 member-zone Hitachi_HNAS_n1fc3 member-zone Hitachi_HNAS_n2fc3 member-zone IXIA_FCoE zoning defined-configuration zone EMC_VG2_n1fc1 member-entry 50:06:01:61:3e:e0:22:af member-entry 50:06:01:68:3e:e0:22:af member-entry 50:06:01:61:47:60:30:c2 zoning defined-configuration zone EMC_VG2_n2fc1 member-entry 50:06:01:60:47:60:30:c2 member-entry 50:06:01:60:3e:e0:22:af member-entry 50:06:01:69:3e:e0:22:af Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 45
46 zoning defined-configuration zone Hitachi_HNAS_n1fc1 member-entry 50:03:01:70:00:06:45:c1 member-entry 50:06:0e:80:13:27:3d:11 zoning defined-configuration zone Hitachi_HNAS_n1fc3 member-entry 50:03:01:70:00:06:45:c3 member-entry 50:06:0e:80:13:27:3d:21 zoning defined-configuration zone Hitachi_HNAS_n2fc1 member-entry 50:06:0e:80:13:27:3d:11 member-entry 50:03:01:70:00:05:2f:e1 zoning defined-configuration zone Hitachi_HNAS_n2fc3 member-entry 50:06:0e:80:13:27:3d:21 member-entry 50:03:01:70:00:05:2f:e3 zoning defined-configuration zone IXIA_FCoE member-entry 31:00:0e:fc:00:00:00:0a member-entry 32:00:0e:fc:00:00:00:aa zoning enabled-configuration cfg-name nos zoning enabled-configuration default-zone-access allaccess zoning enabled-configuration cfg-action cfg-save role name admin desc Administrator role name user desc User aaa authentication login local aaa accounting exec default start-stop none aaa accounting commands default start-stop none service password-encryption username admin password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role admin desc Administrator username user password "BwrsDbB+tABWGWpINOVKoQ==\n" encryption-level 7 role user desc User cee-map default precedence 1 priority-group-table 1 weight 40 pfc on priority-group-table 15.0 pfc off priority-group-table 15.1 pfc off priority-group-table 15.2 pfc off priority-group-table 15.3 pfc off priority-group-table 15.4 pfc off priority-group-table 15.5 pfc off priority-group-table 15.6 pfc off priority-group-table 15.7 pfc off priority-group-table 2 weight 40 pfc off priority-group-table 3 weight 20 pfc off priority-table remap fabric-priority priority 0 remap lossless-priority priority 0 nas server-ip /32 vlan 978 nas server-ip /32 vlan 978 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 nas server-ip /32 vlan 979 fcoe fabric-map default vlan 1002 san-mode local priority 3 virtual-fabric 128 fcmap 0E:FC:00 advertisement interval 8000 keep-alive timeout interface Vlan 1 interface Vlan Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
47 interface Vlan 978 interface Vlan 979 interface Ve 978 interface Ve 979 fabric route mcast rbridge-id 1 fabric route mcast rbridge-id 2 fabric route mcast rbridge-id 11 fabric route mcast rbridge-id 12 protocol lldp advertise dcbx-fcoe-app-tlv advertise dcbx-fcoe-logical-link-tlv advertise dcbx-iscsi-app-tlv advertise dcbx-tlv advertise optional-tlv system-name system-description Brocade-VDX-VCS 20 vlan dot1q tag native port-profile UpgradedVlanProfile vlan-profile mode trunk trunk allowed vlan all port-profile default vlan-profile mode trunk trunk native-vlan 1 port-profile-domain default port-profile UpgradedVlanProfile class-map cee class-map default rbridge-id 1 ip route / ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-1 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 47
48 hardware-profile kap default clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 rbridge-id 2 ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-2 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 0 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 rbridge-id Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
49 ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-11 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 rbridge-id 12 ip route / ip route / switch-attributes chassis-name VDX6740 switch-attributes host-name CASTOR-VCS20-12 vrf mgmt-vrf address-family ipv4 unicast ip route / address-family ipv6 unicast system-monitor fan threshold marginal-threshold 1 down-threshold 2 system-monitor fan alert state removed action raslog system-monitor power threshold marginal-threshold 1 down-threshold 2 system-monitor power alert state removed action raslog system-monitor temp threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card threshold marginal-threshold 1 down-threshold 2 system-monitor cid-card alert state none action none system-monitor sfp alert state none action none system-monitor compact-flash threshold marginal-threshold 1 down-threshold 0 system-monitor MM threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard threshold marginal-threshold 1 down-threshold 2 system-monitor LineCard alert state none action none system-monitor SFM threshold marginal-threshold 1 down-threshold 2 no protocol vrrp Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 49
50 no protocol vrrp-extended hardware-profile tcam default hardware-profile route-table default maximum_paths 8 openflow off hardware-profile kap default clock timezone America/Boise ag no enable root enable ssh server key rsa 2048 ssh server key ecdsa 256 ssh server key dsa fcoe fcoe-enodes 64 interface Ve 978 ip proxy-arp ip address /16 interface Ve 979 ip mtu 9018 ip proxy-arp ip address /16 interface Management 1/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface Management 2/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface Management 11/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface Management 12/0 no tcp burstrate ip icmp echo-reply no ip address dhcp ip address /20 ipv6 icmpv6 echo-reply no ipv6 address autoconfig no ipv6 address dhcp vrf forwarding mgmt-vrf interface TenGigabitEthernet 1/0/1 channel-group 101 mode active type standard no no lacp timeout long 50 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
51 interface TenGigabitEthernet 1/0/2 channel-group 102 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/3 channel-group 103 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/4 channel-group 104 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 1/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 1/0/8 interface TenGigabitEthernet 1/0/9 interface TenGigabitEthernet 1/0/10 interface TenGigabitEthernet 1/0/11 interface TenGigabitEthernet 1/0/12 interface TenGigabitEthernet 1/0/13 interface TenGigabitEthernet 1/0/14 interface TenGigabitEthernet 1/0/15 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 51
52 interface TenGigabitEthernet 1/0/16 interface TenGigabitEthernet 1/0/17 interface TenGigabitEthernet 1/0/18 interface TenGigabitEthernet 1/0/19 interface TenGigabitEthernet 1/0/20 interface TenGigabitEthernet 1/0/21 interface TenGigabitEthernet 1/0/22 interface TenGigabitEthernet 1/0/23 interface TenGigabitEthernet 1/0/24 interface TenGigabitEthernet 1/0/25 interface TenGigabitEthernet 1/0/26 interface TenGigabitEthernet 1/0/27 interface TenGigabitEthernet 1/0/28 interface TenGigabitEthernet 1/0/29 interface TenGigabitEthernet 1/0/30 52 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
53 interface TenGigabitEthernet 1/0/31 mode access access vlan 979 no no interface TenGigabitEthernet 1/0/32 interface TenGigabitEthernet 1/0/33 description VLAN_864_uplink mode access access vlan 864 interface TenGigabitEthernet 1/0/34 interface TenGigabitEthernet 1/0/35 interface TenGigabitEthernet 1/0/36 interface TenGigabitEthernet 1/0/37 interface TenGigabitEthernet 1/0/38 interface TenGigabitEthernet 1/0/39 interface TenGigabitEthernet 1/0/40 interface TenGigabitEthernet 1/0/41 interface TenGigabitEthernet 1/0/42 interface TenGigabitEthernet 1/0/43 interface TenGigabitEthernet 1/0/44 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 53
54 interface TenGigabitEthernet 1/0/45 shutdown interface TenGigabitEthernet 1/0/46 shutdown interface TenGigabitEthernet 1/0/47 shutdown interface TenGigabitEthernet 1/0/48 shutdown interface TenGigabitEthernet 2/0/1 channel-group 101 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/2 channel-group 102 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/3 channel-group 103 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/4 channel-group 104 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/5 channel-group 105 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/6 channel-group 106 mode active type standard no no lacp timeout long interface TenGigabitEthernet 2/0/7 channel-group 107 mode on type standard no no interface TenGigabitEthernet 2/0/8 interface TenGigabitEthernet 2/0/9 54 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
55 interface TenGigabitEthernet 2/0/10 interface TenGigabitEthernet 2/0/11 interface TenGigabitEthernet 2/0/12 interface TenGigabitEthernet 2/0/13 interface TenGigabitEthernet 2/0/14 interface TenGigabitEthernet 2/0/15 interface TenGigabitEthernet 2/0/16 interface TenGigabitEthernet 2/0/20 interface TenGigabitEthernet 2/0/24 interface TenGigabitEthernet 2/0/25 interface TenGigabitEthernet 2/0/26 interface TenGigabitEthernet 2/0/27 interface TenGigabitEthernet 2/0/28 interface TenGigabitEthernet 2/0/29 interface TenGigabitEthernet 2/0/30 interface TenGigabitEthernet 2/0/31 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 55
56 interface TenGigabitEthernet 2/0/32 interface TenGigabitEthernet 2/0/33 interface TenGigabitEthernet 2/0/34 interface TenGigabitEthernet 2/0/35 interface TenGigabitEthernet 2/0/36 interface TenGigabitEthernet 2/0/37 interface TenGigabitEthernet 2/0/38 interface TenGigabitEthernet 2/0/39 interface TenGigabitEthernet 2/0/40 interface TenGigabitEthernet 2/0/41 interface TenGigabitEthernet 2/0/42 interface TenGigabitEthernet 2/0/43 interface TenGigabitEthernet 2/0/44 interface TenGigabitEthernet 2/0/45 shutdown interface TenGigabitEthernet 2/0/46 shutdown 56 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
57 interface TenGigabitEthernet 2/0/47 shutdown interface TenGigabitEthernet 2/0/48 shutdown interface TenGigabitEthernet 11/0/1 channel-group 11 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/2 mode access access vlan 979 interface TenGigabitEthernet 11/0/3 channel-group 21 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/4 cee default mode access access vlan 979 interface TenGigabitEthernet 11/0/5 channel-group 31 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/6 channel-group 32 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/7 mode access access vlan 979 interface TenGigabitEthernet 11/0/8 interface TenGigabitEthernet 11/0/9 channel-group 41 mode active type standard lacp timeout long Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 57
58 interface TenGigabitEthernet 11/0/10 mode access access vlan 979 interface TenGigabitEthernet 11/0/11 mode access access vlan 978 interface TenGigabitEthernet 11/0/12 interface TenGigabitEthernet 11/0/13 cee default mode access access vlan 978 interface TenGigabitEthernet 11/0/14 interface TenGigabitEthernet 11/0/15 mode access access vlan 978 interface TenGigabitEthernet 11/0/16 channel-group 51 mode active type standard lacp timeout long interface TenGigabitEthernet 11/0/17 interface TenGigabitEthernet 11/0/18 interface TenGigabitEthernet 11/0/19 interface TenGigabitEthernet 11/0/20 interface TenGigabitEthernet 11/0/21 58 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
59 interface TenGigabitEthernet 11/0/22 interface TenGigabitEthernet 11/0/23 mode access access vlan 979 interface TenGigabitEthernet 11/0/24 mode access access vlan 979 interface TenGigabitEthernet 11/0/25 mode access access vlan 979 interface TenGigabitEthernet 11/0/26 mode access access vlan 979 interface TenGigabitEthernet 11/0/27 mode access access vlan 979 interface TenGigabitEthernet 11/0/28 mode access access vlan 979 interface TenGigabitEthernet 11/0/29 mode access access vlan 979 interface TenGigabitEthernet 11/0/30 mode access access vlan 979 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 59
60 interface TenGigabitEthernet 11/0/31 cee default mode access access vlan 979 interface TenGigabitEthernet 11/0/32 mode access access vlan 979 fcoeport default interface TenGigabitEthernet 11/0/33 channel-group 33 mode on type standard interface TenGigabitEthernet 11/0/34 interface TenGigabitEthernet 11/0/35 interface TenGigabitEthernet 11/0/36 interface TenGigabitEthernet 11/0/37 channel-group 1 mode on type standard no no interface TenGigabitEthernet 11/0/38 interface TenGigabitEthernet 11/0/39 interface TenGigabitEthernet 11/0/40 interface TenGigabitEthernet 11/0/41 interface TenGigabitEthernet 11/0/42 interface TenGigabitEthernet 11/0/43 interface TenGigabitEthernet 11/0/44 60 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
61 interface TenGigabitEthernet 11/0/45 interface TenGigabitEthernet 11/0/46 interface TenGigabitEthernet 11/0/47 interface TenGigabitEthernet 11/0/48 interface TenGigabitEthernet 12/0/1 channel-group 11 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/2 mode access access vlan 979 no no interface TenGigabitEthernet 12/0/3 channel-group 21 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/4 interface TenGigabitEthernet 12/0/5 channel-group 31 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/6 channel-group 32 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/7 mode access access vlan 979 no no interface TenGigabitEthernet 12/0/8 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 61
62 interface TenGigabitEthernet 12/0/9 channel-group 41 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/10 interface TenGigabitEthernet 12/0/11 mode access access vlan 979 no no interface TenGigabitEthernet 12/0/12 interface TenGigabitEthernet 12/0/13 cee default mode access access vlan 979 no no interface TenGigabitEthernet 12/0/14 interface TenGigabitEthernet 12/0/15 mode access access vlan 978 no no interface TenGigabitEthernet 12/0/16 channel-group 51 mode active type standard no no lacp timeout long interface TenGigabitEthernet 12/0/20 interface TenGigabitEthernet 12/0/24 interface TenGigabitEthernet 12/0/25 interface TenGigabitEthernet 12/0/26 62 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
63 interface TenGigabitEthernet 12/0/27 interface TenGigabitEthernet 12/0/28 interface TenGigabitEthernet 12/0/29 interface TenGigabitEthernet 12/0/30 interface TenGigabitEthernet 12/0/31 cee default mode access access vlan 979 no no interface TenGigabitEthernet 12/0/32 mode access access vlan 979 no no fcoeport default interface TenGigabitEthernet 12/0/33 channel-group 33 mode on type standard no no interface TenGigabitEthernet 12/0/34 no no interface TenGigabitEthernet 12/0/35 mode access access vlan 979 no no interface TenGigabitEthernet 12/0/36 mode access access vlan 979 no no interface TenGigabitEthernet 12/0/37 channel-group 1 mode on type standard no no interface TenGigabitEthernet 12/0/38 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 63
64 interface TenGigabitEthernet 12/0/39 interface TenGigabitEthernet 12/0/40 interface TenGigabitEthernet 12/0/41 interface TenGigabitEthernet 12/0/42 interface TenGigabitEthernet 12/0/43 interface TenGigabitEthernet 12/0/44 interface TenGigabitEthernet 12/0/45 interface TenGigabitEthernet 12/0/46 interface TenGigabitEthernet 12/0/47 interface TenGigabitEthernet 12/0/48 interface FortyGigabitEthernet 1/0/49 interface FortyGigabitEthernet 1/0/50 interface FortyGigabitEthernet 1/0/51 interface FortyGigabitEthernet 1/0/52 interface FortyGigabitEthernet 2/0/49 64 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
65 interface FortyGigabitEthernet 2/0/50 interface FortyGigabitEthernet 2/0/51 interface FortyGigabitEthernet 2/0/52 no interface FortyGigabitEthernet 11/0/49 interface FortyGigabitEthernet 11/0/50 interface FortyGigabitEthernet 11/0/51 interface FortyGigabitEthernet 11/0/52 interface FortyGigabitEthernet 12/0/49 interface FortyGigabitEthernet 12/0/50 interface FortyGigabitEthernet 12/0/51 interface FortyGigabitEthernet 12/0/52 interface Port-channel 1 vlag ignore-split mode access access vlan 979 interface Port-channel 11 vlag ignore-split mode access access vlan 979 interface Port-channel 21 cee default vlag ignore-split mode access access vlan 979 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 65
66 interface Port-channel 31 vlag ignore-split mtu 9216 mode trunk trunk allowed vlan add trunk tag native-vlan interface Port-channel 32 vlag ignore-split mtu 9216 mode trunk trunk allowed vlan add trunk tag native-vlan interface Port-channel 33 no vlag ignore-split mtu 9216 mode access access vlan 979 interface Port-channel 41 vlag ignore-split mode access access vlan 979 interface Port-channel 51 vlag ignore-split mode access access vlan 979 interface Port-channel 101 vlag ignore-split mode trunk trunk allowed vlan add trunk tag native-vlan interface Port-channel 102 vlag ignore-split mode trunk trunk allowed vlan add trunk tag native-vlan interface Port-channel 103 vlag ignore-split mode trunk trunk allowed vlan add trunk tag native-vlan interface Port-channel 104 vlag ignore-split mode trunk 66 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
67 trunk allowed vlan add trunk tag native-vlan interface Port-channel 105 vlag ignore-split mode trunk trunk allowed vlan add 864, trunk tag native-vlan interface Port-channel 106 vlag ignore-split mode trunk trunk allowed vlan add 864, trunk tag native-vlan interface Port-channel 107 no vlag ignore-split mode trunk trunk allowed vlan add trunk tag native-vlan interface FibreChannel 2/0/17 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/18 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/19 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/21 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/22 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 2/0/23 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/17 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/18 no isl-r_rdy trunk-enable fec-enable Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 67
68 interface FibreChannel 12/0/19 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/21 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/22 no isl-r_rdy trunk-enable fec-enable interface FibreChannel 12/0/23 no isl-r_rdy trunk-enable fec-enable interface Fcoe 1/1/1 interface Fcoe 1/1/2 interface Fcoe 1/1/3 interface Fcoe 1/1/4 interface Fcoe 1/1/5 interface Fcoe 1/1/6 interface Fcoe 1/1/7 interface Fcoe 1/1/8 interface Fcoe 1/1/9 interface Fcoe 1/1/10 interface Fcoe 1/1/11 interface Fcoe 1/1/12 interface Fcoe 1/1/13 interface Fcoe 1/1/14 interface Fcoe 1/1/15 interface Fcoe 1/1/16 interface Fcoe 1/1/17 interface Fcoe 1/1/18 68 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
69 interface Fcoe 1/1/19 interface Fcoe 1/1/20 interface Fcoe 1/1/21 interface Fcoe 1/1/22 interface Fcoe 1/1/23 interface Fcoe 1/1/24 interface Fcoe 1/1/25 interface Fcoe 1/1/26 interface Fcoe 1/1/27 interface Fcoe 1/1/28 interface Fcoe 1/1/29 interface Fcoe 1/1/30 interface Fcoe 1/1/31 interface Fcoe 1/1/32 interface Fcoe 1/1/33 interface Fcoe 1/1/34 interface Fcoe 1/1/35 interface Fcoe 1/1/36 interface Fcoe 1/1/37 interface Fcoe 1/1/38 interface Fcoe 1/1/39 interface Fcoe 1/1/40 interface Fcoe 1/1/41 interface Fcoe 1/1/42 interface Fcoe 1/1/43 interface Fcoe 1/1/44 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 69
70 interface Fcoe 1/1/45 interface Fcoe 1/1/46 interface Fcoe 1/1/47 interface Fcoe 1/1/48 interface Fcoe 1/1/49 interface Fcoe 1/1/50 interface Fcoe 1/1/51 interface Fcoe 1/1/52 interface Fcoe 1/1/53 interface Fcoe 1/1/54 interface Fcoe 1/1/55 interface Fcoe 1/1/56 interface Fcoe 1/1/57 interface Fcoe 1/1/58 interface Fcoe 1/1/59 interface Fcoe 1/1/60 interface Fcoe 1/1/61 interface Fcoe 1/1/62 interface Fcoe 1/1/63 interface Fcoe 1/1/64 interface Fcoe 1/2/1 interface Fcoe 1/2/2 interface Fcoe 1/2/3 interface Fcoe 1/2/4 interface Fcoe 1/2/5 interface Fcoe 1/2/6 70 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
71 interface Fcoe 1/2/7 interface Fcoe 1/2/8 interface Fcoe 1/2/9 interface Fcoe 1/2/10 interface Fcoe 1/2/11 interface Fcoe 1/2/12 interface Fcoe 1/2/13 interface Fcoe 1/2/14 interface Fcoe 1/2/15 interface Fcoe 1/2/16 interface Fcoe 1/2/17 interface Fcoe 1/2/18 interface Fcoe 1/2/19 interface Fcoe 1/2/20 interface Fcoe 1/2/21 interface Fcoe 1/2/22 interface Fcoe 1/2/23 interface Fcoe 1/2/24 interface Fcoe 1/2/25 interface Fcoe 1/2/26 interface Fcoe 1/2/27 interface Fcoe 1/2/28 interface Fcoe 1/2/29 interface Fcoe 1/2/30 interface Fcoe 1/2/31 interface Fcoe 1/2/32 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 71
72 interface Fcoe 1/2/33 interface Fcoe 1/2/34 interface Fcoe 1/2/35 interface Fcoe 1/2/36 interface Fcoe 1/2/37 interface Fcoe 1/2/38 interface Fcoe 1/2/39 interface Fcoe 1/2/40 interface Fcoe 1/2/41 interface Fcoe 1/2/42 interface Fcoe 1/2/43 interface Fcoe 1/2/44 interface Fcoe 1/2/45 interface Fcoe 1/2/46 interface Fcoe 1/2/47 interface Fcoe 1/2/48 interface Fcoe 1/2/49 interface Fcoe 1/2/50 interface Fcoe 1/2/51 interface Fcoe 1/2/52 interface Fcoe 1/2/53 interface Fcoe 1/2/54 interface Fcoe 1/2/55 interface Fcoe 1/2/56 interface Fcoe 1/2/57 interface Fcoe 1/2/58 72 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
73 interface Fcoe 1/2/59 interface Fcoe 1/2/60 interface Fcoe 1/2/61 interface Fcoe 1/2/62 interface Fcoe 1/2/63 interface Fcoe 1/2/64 interface Fcoe 1/11/1 interface Fcoe 1/11/2 interface Fcoe 1/11/3 interface Fcoe 1/11/4 interface Fcoe 1/11/5 interface Fcoe 1/11/6 interface Fcoe 1/11/7 interface Fcoe 1/11/8 interface Fcoe 1/11/9 interface Fcoe 1/11/10 interface Fcoe 1/11/11 interface Fcoe 1/11/12 interface Fcoe 1/11/13 interface Fcoe 1/11/14 interface Fcoe 1/11/15 interface Fcoe 1/11/16 interface Fcoe 1/11/17 interface Fcoe 1/11/18 interface Fcoe 1/11/19 interface Fcoe 1/11/20 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 73
74 interface Fcoe 1/11/21 interface Fcoe 1/11/22 interface Fcoe 1/11/23 interface Fcoe 1/11/24 interface Fcoe 1/11/25 interface Fcoe 1/11/26 interface Fcoe 1/11/27 interface Fcoe 1/11/28 interface Fcoe 1/11/29 interface Fcoe 1/11/30 interface Fcoe 1/11/31 interface Fcoe 1/11/32 interface Fcoe 1/11/33 interface Fcoe 1/11/34 interface Fcoe 1/11/35 interface Fcoe 1/11/36 interface Fcoe 1/11/37 interface Fcoe 1/11/38 interface Fcoe 1/11/39 interface Fcoe 1/11/40 interface Fcoe 1/11/41 interface Fcoe 1/11/42 interface Fcoe 1/11/43 interface Fcoe 1/11/44 interface Fcoe 1/11/45 interface Fcoe 1/11/46 74 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
75 interface Fcoe 1/11/47 interface Fcoe 1/11/48 interface Fcoe 1/11/49 interface Fcoe 1/11/50 interface Fcoe 1/11/51 interface Fcoe 1/11/52 interface Fcoe 1/11/53 interface Fcoe 1/11/54 interface Fcoe 1/11/55 interface Fcoe 1/11/56 interface Fcoe 1/11/57 interface Fcoe 1/11/58 interface Fcoe 1/11/59 interface Fcoe 1/11/60 interface Fcoe 1/11/61 interface Fcoe 1/11/62 interface Fcoe 1/11/63 interface Fcoe 1/11/64 interface Fcoe 1/12/1 interface Fcoe 1/12/2 interface Fcoe 1/12/3 interface Fcoe 1/12/4 interface Fcoe 1/12/5 interface Fcoe 1/12/6 interface Fcoe 1/12/7 interface Fcoe 1/12/8 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 75
76 interface Fcoe 1/12/9 interface Fcoe 1/12/10 interface Fcoe 1/12/11 interface Fcoe 1/12/12 interface Fcoe 1/12/13 interface Fcoe 1/12/14 interface Fcoe 1/12/15 interface Fcoe 1/12/16 interface Fcoe 1/12/17 interface Fcoe 1/12/18 interface Fcoe 1/12/19 interface Fcoe 1/12/20 interface Fcoe 1/12/21 interface Fcoe 1/12/22 interface Fcoe 1/12/23 interface Fcoe 1/12/24 interface Fcoe 1/12/25 interface Fcoe 1/12/26 interface Fcoe 1/12/27 interface Fcoe 1/12/28 interface Fcoe 1/12/29 interface Fcoe 1/12/30 interface Fcoe 1/12/31 interface Fcoe 1/12/32 interface Fcoe 1/12/33 interface Fcoe 1/12/34 76 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
77 interface Fcoe 1/12/35 interface Fcoe 1/12/36 interface Fcoe 1/12/37 interface Fcoe 1/12/38 interface Fcoe 1/12/39 interface Fcoe 1/12/40 interface Fcoe 1/12/41 interface Fcoe 1/12/42 interface Fcoe 1/12/43 interface Fcoe 1/12/44 interface Fcoe 1/12/45 interface Fcoe 1/12/46 interface Fcoe 1/12/47 interface Fcoe 1/12/48 interface Fcoe 1/12/49 interface Fcoe 1/12/50 interface Fcoe 1/12/51 interface Fcoe 1/12/52 interface Fcoe 1/12/53 interface Fcoe 1/12/54 interface Fcoe 1/12/55 interface Fcoe 1/12/56 interface Fcoe 1/12/57 interface Fcoe 1/12/58 interface Fcoe 1/12/59 interface Fcoe 1/12/60 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report 77
78 interface Fcoe 1/12/61 interface Fcoe 1/12/62 interface Fcoe 1/12/63 interface Fcoe 1/12/64 < =========== > 78 Brocade VCS Fabric Technology with the EMC Isilon NAS Storage Array Validation Test Report
Brocade VCS Fabric Technology with the EMC VNX5300
Junet 2015 Brocade VCS Fabric Technology with the EMC VNX5300 Test Report Supporting Network OS 6.0.1 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the
Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array
November 2015 Brocade VCS Fabric Technology with the NetApp 3170 NAS Storage Array Validation Test Report Supporting Network OS 6.0.1 and 4.1.2 2015, Brocade Communications Systems, Inc. All Rights Reserved.
Nutanix Hyperconverged Appliance with the Brocade VDX ToR Switch Deployment Guide
January 8, 2016 Nutanix Hyperconverged Appliance with the Brocade VDX ToR Switch Deployment Guide 2016 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol,
VCS Monitoring and Troubleshooting Using Brocade Network Advisor
VCS Monitoring and Troubleshooting Using Brocade Network Advisor Brocade Network Advisor is a unified network management platform to manage the entire Brocade network, including both SAN and IP products.
Brocade Solution for EMC VSPEX Server Virtualization
Reference Architecture Brocade Solution Blueprint Brocade Solution for EMC VSPEX Server Virtualization Microsoft Hyper-V for 50 & 100 Virtual Machines Enabled by Microsoft Hyper-V, Brocade ICX series switch,
Next-Gen Security Architecture through Brocade Network Devices and Palo Alto Networks Firewall
S Next-Gen Security Architecture through Brocade Network Devices and Palo Alto Networks Firewall This solution leverages interoperable and best-of-breed networking and security products, tailored to fit
DEDICATED NETWORKS FOR IP STORAGE
DEDICATED NETWORKS FOR IP STORAGE ABSTRACT This white paper examines EMC and VMware best practices for deploying dedicated IP storage networks in medium to large-scale data centers. In addition, it explores
VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS
VIDEO SURVEILLANCE WITH SURVEILLUS VMS AND EMC ISILON STORAGE ARRAYS Successfully configure all solution components Use VMS at the required bandwidth for NAS storage Meet the bandwidth demands of a 2,200
Brocade VCS Fabric Technology and NAS with NFS Validation Test
Brocade VCS Fabric Technology and NAS with NFS Validation Test NetApp/VMware vsphere 5.0 Red Hat Enterprise Linux This material outlines sample configurations and associated test results of Brocade VCS
Brocade Network Advisor High Availability Using Microsoft Cluster Service
Brocade Network Advisor High Availability Using Microsoft Cluster Service This paper discusses how installing Brocade Network Advisor on a pair of Microsoft Cluster Service nodes provides automatic failover
DATA CENTER. Best Practices for High Availability Deployment for the Brocade ADX Switch
DATA CENTER Best Practices for High Availability Deployment for the Brocade ADX Switch CONTENTS Contents... 2 Executive Summary... 3 Introduction... 3 Brocade ADX HA Overview... 3 Hot-Standby HA... 4 Active-Standby
ADVANCED NETWORK CONFIGURATION GUIDE
White Paper ADVANCED NETWORK CONFIGURATION GUIDE CONTENTS Introduction 1 Terminology 1 VLAN configuration 2 NIC Bonding configuration 3 Jumbo frame configuration 4 Other I/O high availability options 4
Brocade One Data Center Cloud-Optimized Networks
POSITION PAPER Brocade One Data Center Cloud-Optimized Networks Brocade s vision, captured in the Brocade One strategy, is a smooth transition to a world where information and applications reside anywhere
Ethernet Fabrics: An Architecture for Cloud Networking
WHITE PAPER www.brocade.com Data Center Ethernet Fabrics: An Architecture for Cloud Networking As data centers evolve to a world where information and applications can move anywhere in the cloud, classic
Virtual Connect Enterprise Manager Server Guide
53-1004163-02 06 May 2016 Virtual Connect Enterprise Manager Server Guide Supporting Network Advisor 14.0.1 Copyright 2016 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade
Brocade SAN Scalability Guidelines: Brocade Fabric OS v7.x
Brocade SAN Scalability Guidelines: Brocade Fabric OS v7.x Version 7.2, update 1 Dated: February 5, 2014 This document provides scalability guidelines that can be used to design and deploy extremely stable
Scalable Approaches for Multitenant Cloud Data Centers
WHITE PAPER www.brocade.com DATA CENTER Scalable Approaches for Multitenant Cloud Data Centers Brocade VCS Fabric technology is the ideal Ethernet infrastructure for cloud computing. It is manageable,
The Business Case for Software-Defined Networking
WHITE PAPER The Business Case for Software-Defined Networking Brocade enables customers a means of reducing costs of service delivery through Software-Defined Networking (SDN) technologies. In addition,
Brocade Virtual Traffic Manager and Microsoft IIS Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Microsoft IIS Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX,
N5 NETWORKING BEST PRACTICES
N5 NETWORKING BEST PRACTICES Table of Contents Nexgen N5 Networking... 2 Overview of Storage Networking Best Practices... 2 Recommended Switch features for an iscsi Network... 2 Setting up the iscsi Network
Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study
White Paper Microsoft SQL Server 2012 on Cisco UCS with iscsi-based Storage Access in VMware ESX Virtualization Environment: Performance Study 2012 Cisco and/or its affiliates. All rights reserved. This
Nutanix Tech Note. VMware vsphere Networking on Nutanix
Nutanix Tech Note VMware vsphere Networking on Nutanix Nutanix Virtual Computing Platform is engineered from the ground up for virtualization and cloud environments. This Tech Note describes vsphere networking
How To Connect Virtual Fibre Channel To A Virtual Box On A Hyperv Virtual Machine
Virtual Fibre Channel for Hyper-V Virtual Fibre Channel for Hyper-V, a new technology available in Microsoft Windows Server 2012, allows direct access to Fibre Channel (FC) shared storage by multiple guest
BRIDGING EMC ISILON NAS ON IP TO INFINIBAND NETWORKS WITH MELLANOX SWITCHX
White Paper BRIDGING EMC ISILON NAS ON IP TO INFINIBAND NETWORKS WITH Abstract This white paper explains how to configure a Mellanox SwitchX Series switch to bridge the external network of an EMC Isilon
Cloud Optimized Performance: I/O-Intensive Workloads Using Flash-Based Storage
WHITE PAPER Cloud Optimized Performance: I/O-Intensive Workloads Using Flash-Based Storage Brocade continues to innovate by delivering the industry s first 16 Gbps switches for low latency and high transaction
Multitenancy Options in Brocade VCS Fabrics
WHITE PAPER DATA CENTER Multitenancy Options in Brocade VCS Fabrics As cloud environments reach mainstream adoption, achieving scalable network segmentation takes on new urgency to support multitenancy.
Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches
Migration Guide Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide November 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is
BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012
BASCS in a Nutshell Study Guide for Exam 160-020 Brocade University Revision 03-2012 2013 Brocade Communications Corporate Headquarters - San Jose, CA USA T: (408) 333-8000 [email protected] European Headquarters
ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK
ORACLE OPS CENTER: PROVISIONING AND PATCH AUTOMATION PACK KEY FEATURES PROVISION FROM BARE- METAL TO PRODUCTION QUICKLY AND EFFICIENTLY Controlled discovery with active control of your hardware Automatically
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.
Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials. CHAPTER 5 OBJECTIVES Configure a router with an initial configuration. Use the
Isilon OneFS. Version 7.2.1. OneFS Migration Tools Guide
Isilon OneFS Version 7.2.1 OneFS Migration Tools Guide Copyright 2015 EMC Corporation. All rights reserved. Published in USA. Published July, 2015 EMC believes the information in this publication is accurate
Isilon IQ Network Configuration Guide
Isilon IQ Network Configuration Guide An Isilon Systems Best Practice Paper August 2008 ISILON SYSTEMS Table of Contents Cluster Networking Introduction...3 Assumptions...3 Cluster Networking Features...3
Diagnostics and Troubleshooting Using Event Policies and Actions
Diagnostics and Troubleshooting Using Event Policies and Actions Brocade Network Advisor logs events and alerts generated by managed devices and the management server and presents them through the master
Backup and Recovery with Cisco UCS Solutions for SAP HANA
Configuration Guide Backup and Recovery with Cisco UCS Solutions for SAP HANA Configuration Guide March, 2014 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page
Brocade Fabric Vision Technology Frequently Asked Questions
Brocade Fabric Vision Technology Frequently Asked Questions Introduction This document answers frequently asked questions about Brocade Fabric Vision technology. For more information about Fabric Vision
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance
Dell PowerEdge Blades Outperform Cisco UCS in East-West Network Performance This white paper compares the performance of blade-to-blade network traffic between two enterprise blade solutions: the Dell
vrealize Operations Manager Customization and Administration Guide
vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.0.1 This document supports the version of each product listed and supports all subsequent versions until
HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios
HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios Part number 603028-003 Third edition August 2010 Copyright 2009,2010 Hewlett-Packard Development Company, L.P.
Scale-Out Storage, Scale-Out Compute, and the Network
WHITE PAPER www.brocade.com DATA CENTER Scale-Out Storage, Scale-Out Compute, and the Network Brocade VDX switches with Brocade VCS Fabric technology provide an automated, efficient, scale-out network
BROCADE FABRIC VISION TECHNOLOGY FREQUENTLY ASKED QUESTIONS
FAQ BROCADE FABRIC VISION TECHNOLOGY FREQUENTLY ASKED QUESTIONS Introduction This document answers frequently asked questions about Brocade Fabric Vision technology. For more information about Fabric Vision
53-1003768-01 25 June 2015. Network OS. Administrator s Guide. Supporting Network OS v6.0.1
25 June 2015 Network OS Administrator s Guide Supporting Network OS v6.0.1 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric
Cisco Nexus 5548UP. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide
Cisco Nexus 5548UP Switch Configuration Guide for Dell PS Series SANs Dell Storage Engineering October 2015 A Dell Deployment and Configuration Guide Revisions Date February 2013 October 2013 March 2014
Where IT perceptions are reality. Test Report. OCe14000 Performance. Featuring Emulex OCe14102 Network Adapters Emulex XE100 Offload Engine
Where IT perceptions are reality Test Report OCe14000 Performance Featuring Emulex OCe14102 Network Adapters Emulex XE100 Offload Engine Document # TEST2014001 v9, October 2014 Copyright 2014 IT Brand
White Paper. SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family
White Paper SAP NetWeaver Landscape Virtualization Management on VCE Vblock System 300 Family Table of Contents 2 Introduction 3 A Best-of-Breed Integrated Operations Architecture 3 SAP NetWeaver Landscape
VMware Virtual SAN 6.2 Network Design Guide
VMware Virtual SAN 6.2 Network Design Guide TECHNICAL WHITE PAPER APRIL 2016 Contents Intended Audience... 2 Overview... 2 Virtual SAN Network... 2 Physical network infrastructure... 3 Data center network...
Brocade Fabric OS DATA CENTER. Target Path Selection Guide. 53-1003916-03 January 4, 2016
January 4, 2016 DATA CENTER Brocade Fabric OS Target Path Selection Guide Brocade Fabric OS (Brocade FOS) Target Path releases are recommended code levels for Brocade Fibre Channel switch platforms. Use
Brocade 5600 vrouter License and Entitlement Management
13 November 2015 Brocade 5600 vrouter License and Entitlement Management Reference Guide Supporting Brocade 5600 vrouter 4.0R1 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade,
WHITE PAPER. Cloud Networking: Scaling Data Centers and Connecting Users
WHITE PAPER Cloud Networking: Scaling Data Centers and Connecting Users While the business promise of cloud computing is broad, there are a few basic enabling themes underlying an effective cloud design:
NetApp Storage System Plug-In 12.1.0.1.0 for Oracle Enterprise Manager 12c Installation and Administration Guide
NetApp Storage System Plug-In 12.1.0.1.0 for Oracle Enterprise Manager 12c Installation and Administration Guide Sachin Maheshwari, Anand Ranganathan, NetApp October 2012 Abstract This document provides
vsphere Networking vsphere 5.5 ESXi 5.5 vcenter Server 5.5 EN-001074-02
vsphere 5.5 ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more
Multi-Chassis Trunking for Resilient and High-Performance Network Architectures
WHITE PAPER www.brocade.com IP Network Multi-Chassis Trunking for Resilient and High-Performance Network Architectures Multi-Chassis Trunking is a key Brocade technology in the Brocade One architecture
Brocade Virtual Traffic Manager and Microsoft SharePoint 2010 Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Microsoft SharePoint 2010 Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing
vsphere Networking ESXi 5.0 vcenter Server 5.0 EN-000599-01
ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions
The Road to SDN: Software-Based Networking and Security from Brocade
WHITE PAPER www.brocade.com SOFTWARE NETWORKING The Road to SDN: Software-Based Networking and Security from Brocade Software-Defined Networking (SDN) presents a new approach to rapidly introducing network
BROCADE NETWORK ADVISOR
DATA SHEET www.brocade.com BROCADE NETWORK ADVISOR NETWORK MANAGEMENT Simplified Network Management for Today s Increasingly Dynamic Networks HIGHLIGHTS Simplifies operations by providing an intuitive
Configuring IPS High Bandwidth Using EtherChannel Load Balancing
Configuring IPS High Bandwidth Using EtherChannel Load Balancing This guide helps you to understand and deploy the high bandwidth features available with IPS v5.1 when used in conjunction with the EtherChannel
IMPLEMENTING VIRTUALIZED AND CLOUD INFRASTRUCTURES NOT AS EASY AS IT SHOULD BE
EMC AND BROCADE - PROVEN, HIGH PERFORMANCE SOLUTIONS FOR YOUR BUSINESS TO ACCELERATE YOUR JOURNEY TO THE CLOUD Understand How EMC VSPEX with Brocade Can Help You Transform IT IMPLEMENTING VIRTUALIZED AND
Design and Implementation Guide. Data Center Design Guide: Implement McAfee Next Generation Firewall for the Perimeter
Data Center Design Guide: Implement McAfee Next Generation Firewall for the Perimeter Table of Contents Introduction...3 McAfee Next Generation Firewall...3 Purpose of the document....3 Audience...3 Resources...3
Brocade VCS Fabrics: The Foundation for Software-Defined Networks
WHITE PAPER DATA CENTER Brocade VCS Fabrics: The Foundation for Software-Defined Networks Software-Defined Networking (SDN) offers significant new opportunities to centralize management and implement network
53-1003126-02 15 August 2014. Access Gateway. Administrator's Guide. Supporting Fabric OS v7.3.0
15 August 2014 Access Gateway Administrator's Guide Supporting Fabric OS v7.3.0 2014, Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, Brocade Assurance, ADX, AnyIO,
Dell EqualLogic Best Practices Series. Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference
Dell EqualLogic Best Practices Series Dell EqualLogic PS Series Reference Architecture for Cisco Catalyst 3750X Two-Switch SAN Reference Storage Infrastructure and Solutions Engineering Dell Product Group
An Oracle White Paper October 2013. How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches
An Oracle White Paper October 2013 How to Connect Oracle Exadata to 10 G Networks Using Oracle s Ethernet Switches Introduction... 1 Exadata Database Machine X3-2 Full Rack Configuration... 1 Multirack
Brocade Virtual Traffic Manager and Magento Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Magento Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric
Data Center Convergence. Ahmad Zamer, Brocade
Ahmad Zamer, Brocade SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted. Member companies and individual members may use this material in presentations
Quantum StorNext. Product Brief: Distributed LAN Client
Quantum StorNext Product Brief: Distributed LAN Client NOTICE This product brief may contain proprietary information protected by copyright. Information in this product brief is subject to change without
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing
IBM TSM DISASTER RECOVERY BEST PRACTICES WITH EMC DATA DOMAIN DEDUPLICATION STORAGE
White Paper IBM TSM DISASTER RECOVERY BEST PRACTICES WITH EMC DATA DOMAIN DEDUPLICATION STORAGE Abstract This white paper focuses on recovery of an IBM Tivoli Storage Manager (TSM) server and explores
NETWORK FUNCTIONS VIRTUALIZATION. The Top Five Virtualization Mistakes
WHITE PAPER www.brocade.com NETWORK FUNCTIONS VIRTUALIZATION The Top Five Virtualization Mistakes Virtualization is taking the IT world by storm. After years of IT build-out, virtualization suddenly fixes
vsphere Networking vsphere 6.0 ESXi 6.0 vcenter Server 6.0 EN-001391-01
vsphere 6.0 ESXi 6.0 vcenter Server 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more
QLogic 3810, QLogic 5000 Series, and QLogic 5800V Series Switch Firmware. Version 7.4.0.29.00. Table of Contents
QLogic 3810, QLogic 5000 Series, and QLogic 5800V Series Switch Firmware Version 7.4.0.29.00 50949-16 Rev A QLogic Corporation All rights reserved Table of Contents 1 Overview 2 Installing the Firmware
Brocade Virtual Traffic Manager and Microsoft Outlook Web Access Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Microsoft Outlook Web Access Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing
Brocade Virtual Traffic Manager and Oracle Application Server 10G Deployment Guide
September 2015 Brocade Virtual Traffic Manager and Oracle Application Server 10G Deployment Guide 2015 Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the B-wing
Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over)
Extreme Networks White Paper Data Center Fabric Convergence for Cloud Computing (the Debate of Ethernet vs. Fibre Channel is Over) The evolution of the data center fabric has been well documented. The
Isilon OneFS. Version 7.2. OneFS Migration Tools Guide
Isilon OneFS Version 7.2 OneFS Migration Tools Guide Copyright 2014 EMC Corporation. All rights reserved. Published in USA. Published November, 2014 EMC believes the information in this publication is
Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version
Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version Topology Objective Background Configure EtherChannel. Four switches have just been installed. The distribution layer switches are Catalyst
全 新 企 業 網 路 儲 存 應 用 THE STORAGE NETWORK MATTERS FOR EMC IP STORAGE PLATFORMS
全 新 企 業 網 路 儲 存 應 用 THE STORAGE NETWORK MATTERS FOR EMC IP STORAGE PLATFORMS Enterprise External Storage Array Capacity Growth IDC s Storage Capacity Forecast = ~40% CAGR (2014/2017) Keep Driving Growth!
A Principled Technologies white paper commissioned by Dell Inc.
A Principled Technologies white paper commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Summary... 3 Features of Simple Switch Mode... 3 Sample scenarios... 5 Testing scenarios... 6 Scenario
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
CCT vs. CCENT Skill Set Comparison
Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification
The Brocade SDN Controller in Modern Service Provider Networks
WHITE PAPER The Controller in Modern Service Provider Networks The OpenDaylight-based Controller combines innovations with modular software engineering and model-driven network management for a cost-effective,
Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support
Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support Topology Objectives Background Configure auto QoS to support IP phones. Configure CoS override for data frames. Configure the distribution
Lab 7-1 Configuring Switches for IP Telephony Support
Lab 7-1 Configuring Switches for IP Telephony Support Learning Objectives Configure auto QoS to support IP phones Configure CoS override for data frames Configure the distribution layer to trust access
Transparent Cache Switching Using Brocade ServerIron and Blue Coat ProxySG
Transparent Cache Switching Using Brocade ServerIron and Blue Coat ProxySG This document provides best-practice guidance for Brocade ServerIron ADC deployments using Transparent Cache Switching (TCS) with
Install Guide for JunosV Wireless LAN Controller
The next-generation Juniper Networks JunosV Wireless LAN Controller is a virtual controller using a cloud-based architecture with physical access points. The current functionality of a physical controller
EMC ViPR for On-Demand File Storage with EMC Syncplicity and EMC Isilon or EMC VNX
EMC ViPR for On-Demand File Storage with EMC Syncplicity and EMC Isilon or EMC VNX EMC Solutions Abstract This document describes how to deploy EMC ViPR software-defined storage in an existing EMC Isilon
Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.
Configuring Single Instance Rapid Spanning Tree Protocol (RSTP) between an Avaya C360 Converged Switch and HP ProCurve Networking Switches to support Avaya IP Telephony Issue 1.0 Abstract These Application
Fibre Channel over Ethernet: Enabling Server I/O Consolidation
WHITE PAPER Fibre Channel over Ethernet: Enabling Server I/O Consolidation Brocade is delivering industry-leading oe solutions for the data center with CNAs, top-of-rack switches, and end-of-row oe blades
Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters
Configure Windows 2012/Windows 2012 R2 with SMB Direct using Emulex OneConnect OCe14000 Series Adapters Emulex OneConnect Ethernet Network Adapters Introduction This document gives an overview of how to
Introduction to VMware EVO: RAIL. White Paper
Introduction to VMware EVO: RAIL White Paper Table of Contents Introducing VMware EVO: RAIL.... 3 Hardware.................................................................... 4 Appliance...............................................................
APPLICATION NOTES High-Availability Load Balancing with the Brocade ServerIron ADX and McAfee Firewall Enterprise (Sidewinder)
High-Availability Load Balancing with the Brocade ServerIron ADX and McAfee Firewall Enterprise (Sidewinder) This solution leverages interoperable and best-of-breed networking and security products, tailored
How To Write An Article On An Hp Appsystem For Spera Hana
Technical white paper HP AppSystem for SAP HANA Distributed architecture with 3PAR StoreServ 7400 storage Table of contents Executive summary... 2 Introduction... 2 Appliance components... 3 3PAR StoreServ
EMC VSPEX END-USER COMPUTING
IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon 6.0 with View and VMware vsphere for up to 2,000 Virtual Desktops Enabled by EMC VNX and EMC Data Protection EMC VSPEX Abstract This describes
Best practices for fully automated disaster recovery of Microsoft SQL Server 2008 using HP Continuous Access EVA with Cluster Extension EVA
Best practices for fully automated disaster recovery of Microsoft SQL Server 2008 using HP Continuous Access EVA with Cluster Extension EVA Subtitle Table of contents Overview... 2 Key findings... 3 Solution
FastIron Ethernet Switch Software Defined Networking (SDN)
31 March 2015 FastIron Ethernet Switch Software Defined Networking (SDN) Configuration Guide Supporting FastIron Software Release 08.0.30 2015, Brocade Communications Systems, Inc. All Rights Reserved.
Veeam Cloud Connect. Version 8.0. Administrator Guide
Veeam Cloud Connect Version 8.0 Administrator Guide April, 2015 2015 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may be
Simplifying Virtual Infrastructures: Ethernet Fabrics & IP Storage
Simplifying Virtual Infrastructures: Ethernet Fabrics & IP Storage David Schmeichel Global Solutions Architect May 2 nd, 2013 Legal Disclaimer All or some of the products detailed in this presentation
EMC VSPEX with Brocade Networking Solution for PRIVATE CLOUD
Proven Infrastructure EMC VSPEX with Brocade Networking Solution for PRIVATE CLOUD Microsoft Windows Server 2012 R2 with Hyper-V for up to 125 Virtual Machines Enabled by Brocade VCS Fabrics, EMC VNXe3200,
Gigabyte Content Management System Console User s Guide. Version: 0.1
Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...