1 Healthcare Solutions What Works and Why
2 1 Our solutions for Hospital and Care Facilities Armitage Shanks creating bathrooms since 1817 In the early years of the 19th century the company that would become Armitage Shanks was founded with a simple objective; to produce sanitaryware of exceptional quality. Now, in the early years of the 21st century, this philosophy, supported by investment in technology and traditional manufacturing skills, still remains at the core of our business Introduced hygienic basin to raise life expectation from 40 years 1912 Marine product fitted in Titanic 1918 Vitreous China superseded earthenware 1928 First sanitaryware colours introduced 1955 Export sales topped a million pounds, 50% of total business 1962 The birth of battery casting
3 Infection Control First to introduce bold colours 1969 Rimless technology invented 1969 Invented pre-plumbed IPS panel system 1986 First fully automated warehouse in the UK 1993 First to introduce fully compliant less-abled Doc M pack 1996 First pressure casting machine installed 2007 Launch of Portman Launch of Markwik Invention of Anti-Pseudomonas BioGuard outlet
4 3 Our solutions for Hospital and Care Facilities Armitage Shanks Continuing to Innovate Armitage Shanks has a history and pedigree of always innovating. By regularly working with and speaking to users, carrying out detailed studies with user groups and by conducting field tests using product concepts and ideas generated by Armitage Shanks, ensures it is always at the cutting edge of new design. Examples of firsts for Armitage Shanks include: - Rimless toilet pans. - Special IPS panel systems for creating hygienic and easy maintenance wall solutions. - Markwik21 with it s unique Anti-Pseudomonas outlet. Over many years Armitage Shanks has had a philosophy of working with some of the World s leading designers and experts examples of which include: - Robin Levien RDI (Royal Designer for Industry) has been working with Armitage Shanks since Robert Feeney (Renowned Ergonomic Scientist). - Dr. Ronald Cutler (Leading Micro-biologist and Expert in Healthcare Infection Control). Armitage Shanks has for nearly 200 years been innovating and creating new ideas and products that really make peoples lives safer and better and it will continue to do so through this century and beyond. OUR APPROACH - Armitage Shanks whole history is embedded in providing innovative solutions to healthcare ceramics and fittings. - Armitage Shanks regularly carries out user group research and testing. - By working with relevant experts Armitage Shanks understands the latest thinking and findings in areas such as infection control. - Armitage Shanks and its designers conduct field testing of new products to ensure complete compatibility with users needs.
5 Infection Control 4 Infection Control Officer Infection control and general hygiene are of paramount importance in healthcare. Sanitary fittings that are easy to clean and actively protect patients are vital. Nurse I want products that are easy to use and deliver hot water safely, are hygienic and meet the latest performance standards. Back Rest Rail and Hinged Support Rail available in white only in the Australian market.
6 5 Our solutions for Hospital and Care Facilities Infection Control Fighting Legionella & Pseudomonas Aeruginosa The chain of infection which propagates and transmits bacteria in healthcare facilities can be broken by modern technology and common sense procedures. LEGIONELLA Legionella bacteria are naturally occurring organisms present in many water systems that can cause the development of Legionnaires disease in people exposed to them. The water conditions liable to affect the growth of Legionella in water systems are varied, however it is commonly agreed upon that: - Legionella bacteria will not easily multiply at water temperatures below 20ºC. - Legionella bacteria proliferate between water temperatures of 20ºC and 45ºC. - Legionella bacteria will die at water temperatures above 60ºC. Minimising the growth of Legionella is possible through water system design when supported by regular risk assessments carried out by qualified staff. The practices below are critical to the success of any Anti-Legionella program. - Water distribution systems should be well maintained and kept in a hygienic condition. - Water supplies should be distributed to the point of mixing at appropriate temperatures, below 20ºC for cold and above 55ºC for hot. - Point of use thermostatic mixers are recommended. Mixing remotely and distributing warm water to multiple points should be avoided. - Hot water should be stored at or above 60ºC. Water temperatures should be monitored throughout the building on a regular basis. - Hot and cold supplies should be kept separate and properly insulated to maintain safe temperatures prior to mixing. - In high risk areas specify fittings with a thermal disinfection facility, supported by a regular sanitisation regime. - In very high risk areas special medical filters could be considered on all sanitary fittings. Filters must be changed regularly to maintain their protection. High levels of Pseudomonas bacteria are often found in the outlets of taps or mixers, especially those fitted with flow modifying devices. Maximise Infection Control with the Markwik21 BioGuard Outlet
7 Infection Control 6 PSEUDOMONAS AERUGINOSA Pseudomonas Aeruginosa is a common bacterium that can cause disease in humans. It is found in soil, water, skin flora, and most man-made environments throughout the world. Because it thrives on most surfaces, Pseudomonas can be found on, and inside, medical equipment such as catheters making it a leading cause of healthcare acquired infections (HAI): - Pseudomonas usually infects people who are immune deficient or whose immune system is suppressed, such as hospital patients. - Healthy people can usually fight off Pseudomonas very successfully before any symptoms become apparent. Pseudomonas can also survive in healthcare water systems. The bacterium has been found to colonise the last 2 metres of the water supply system before the outlet. In this scenario it is likely that pipes, isolation valves, strainers and the tap or mixer itself will all become infected. Such contamination may be caused by water that contains Pseudomonas or by the bacteria entering the system via contaminated hands, cloths or medical equipment contacting the outlet. To prevent the spread of Pseudomonas several actions are recommended: - Regularly check the water supply in all parts of the building for Pseudomonas. - Use all water fittings such as taps, mixers and showers frequently to eliminate standing water, either manually or by electronic duty flush. - Clean the outlets of all fittings correctly and often. - The use of medical filters in high-risk areas like intensive care units and oncology could be considered. - The use of an unrestricted outlet may be appropriate. - Follow the guidelines of local regulators relating to infection control. - Implement infection control procedures in appropriate sanitary facilities. Breaking the chain of infection 6) Susceptible host A sick patient unable to fight the bug 5) Portal of entry The means the bug uses to get inside the host 1) Infectious agent The bug that causes the disease Chain of Infection 4) Mode of transmission The way in which the bug moves from place to place 2) Reservoir The place where the bug reproduces 3) Portal of exit The means the bug uses to leave the reservoir
8 7 Our solutions for Hospital and Care Facilities Advancements in Ceramics & Fittings Technology Portman21 ceramics (wallbasins and toilet pans) are specially designed and developed to help combat HAI s. DESIGN-LED SOLUTIONS FOR PATIENT CARE Best practice states that Hospitals should ensure adequate provision of suitable hand wash facilities. - Basins should be sited, in addition to washroom applications, in all patient areas, treatment rooms, sluices and kitchens. - In clinical areas they should be fitted with wrist or elbow operated mixer taps or ideally a mixer with automatic no touch operation. - In addition, specifying products designed to break the chain of infection will produce a safer environment. The Portman21 Wall Basin The Portman21 wall basin is available without tapholes and without overflow. There are virtually no reservoirs in which water can promote the growth of bacteria. The Rimless Portman21 Toilet Pan In most toilet pans the rim serves one function; to guide the flush water around the pan. Unfortunately, it also provides a residence for bacteria. The Rimless Portman21 toilet pan has no rim. A single, easy to disinfect, outlet works with an internal pan design to flush the toilet pan. Performance and hygiene, by design. - The best way to stop HAI is to eliminate the infectious agent or deny it a reservoir in which to grow. Armitage Shanks products are designed to do just that. Back Rest Rail and Hinged Support Rail available in white only in the Australian market.
9 Infection Control 8 Infection Control Markwik21 Armitage Shanks healthcare fittings are designed and regularly updated to take into account the latest research and knowledge. FIGHTING HEALTHCARE ACQUIRED INFECTIONS (HAI) Armitage Shanks range of Markwik21 taps and mixers build on their successful past and utilise the latest technologies and materials to fight HAI: - Key Markwik21 fittings are supplied with a patent pending Anti- Pseudomonas BioGuard outlet that has no grid and a smooth copper lining (copper acts as a natural bacteria growth inhibitor). - The Markwik21 thermostatic basin mixer is supplied with copper tails instead of flexible hoses that are known to sometimes harbour bacteria. - Markwik21 s Hydro-Purge facility allows quick removal of debris prior to commissioning, which can promote bacterial growth, from water supply pipes without damaging the fitting. - Markwik21 has a demountable body and spout that allows for complete emersed disinfection helping to reduce the risk of Pseudomonas Aeruginosa and Legionella infection. Detachable Spout The Markwik21 detachable spout allows autoclave cleaning to prevent biofilm attachment and help reduce the risk of bacterial infection. Detachable Spout Markwik21 s new Anti-Pseudomonas BioGuard outlet provides additional protection by reducing the chances of biofilm build-up. Markwik21 BioGuard Outlet
10 9 Our solutions for Hospital and Care Facilities Markwik21 Total Disinfection Control With an ever-increasing focus on preventing infection, hygiene has never been more important. And nowhere more so than in the water supply where common bacteria like Pseudomonas aeruginosa and Legionella can be found. Armitage Shanks range of Markwik21 taps and mixers has continually evolved to respond to market demands and today offers the most comprehensive range of disinfection regimes to help you successfully fight bacterial infection.
11 Infection Control 10 We 100% air test our Markwik21 fittings. MAKING INFECTION CONTROL EASIER Markwik21 is 100% Air Tested As part of our Total Disinfection Control program no water is used to test our fittings, instead we 100% air test our Markwik21 fittings to ensure products leaving our manufacturing facilities are infection free. It is widely accepted that Pseudomonas has a rapid rate of mutation, which can mean it becomes increasingly resistant to any singular cleaning process. Therefore changing cleaning regimes in the hospital setting between chemical, thermal and high velocity flushing is believed to be the most effective approach.
12 11 Our solutions for Hospital and Care Facilities Submerge and disinfect Demountable body and spout allows for completely immersed disinfection helping to reduce the risk of Pseudomonas aeruginosa and Legionella infection. Inlet caps prevents contamination during sterilisation AS/NZS compliant. AS2345 (DZR) compliant. TMV3 compliant. Watermark approved. Approved by NSW Health.
13 Infection Control 12 Detach and sterilise The Markwik21 detachable spout allows autoclave cleaning to prevent biofilm attachment and help reduce the risk of bacterial infection. AUTOCLAVE COMPATIBLE A fresh start, time and time again The Markwik21 Hydro-Purge facility flushes water through pipework and inlets to ensure a debris free system after initial installation or after further installations on the same plumbing system. It also enables flushing after chemical disinfection. AS/NZS compliant. AS2345 (DZR) compliant. TMV3 compliant. Watermark approved. Approved by NSW Health.
14 13 Our solutions for Hospital and Care Facilities BioGuard against bacteria BioGuard patent pending anti-microbial copper outlet helps to prevent biofilm attachment and reduce the risk of Pseudomonas infection. BioGuard patent pending outlet AS/NZS compliant. AS2345 (DZR) compliant. TMV3 compliant. Watermark approved. Approved by NSW Health.
15 Infection Control 14 Forward thinking The Markwik21 integral thermostat enables water to be mixed closer to the point of discharge. The dead leg of cold water is eliminated and the volume of mixed water is reduced, minimising areas of warm water which provides the ideal conditions for bacteria to grow. Integral TMV The horizontal spout allows warm water to fully drain Markwik21 technolgy eliminates opportunity for bacteria to grow TMV Cold water dead leg Swan neck dead leg Mixed water supply dead leg AS/NZS compliant. AS2345 (DZR) compliant. Standard TMV set up enables more instances for bacteria to grow TMV3 compliant. Watermark approved. Approved by NSW Health.
16 15 Our solutions for Hospital and Care Facilities Rimless Toilet Pan In 1969 Armitage Shanks invented and patented the very first Rimless toilet pan. In conjunction with a highly experienced Architect, Armitage Shanks did what it does best and utilised it s hands-on knowledge of the specialist needs of healthcare environments and teamed-up with an expert of the built-environment. This collaboration changed the face of healthcare sanitaryware forever and has possibly saved many lives as a result. Rimless was one of the great innovations to come out of this design study and meant for the first time that the toilet pan was much easier to clean and as a result more hygienic for users. In the UK Rimless toilet pans are now the norm in all clinical areas within healthcare buildings, and over the last 10 years the use of Rimless toilet pans across the rest of Europe and the World have been growing at a very fast pace. Over the years since 1969 Armitage Shanks has not only increased the number and types of toilet pan that use Rimless flushing but has also continued to evolve the technology and innovate. The current patented Rimless engine has been developed using experienced engineers with a high degree of knowledge and expertise in the field of Rimless flushing. This new design incorporates an injection system that is even easier to clean, providing probably the best flushing performance of any Rimless toilet pan used in Healthcare with particular attention paid to the fast and efficient removal of toilet pan contents. In addition there is now only an injection system positioned at the back of the toilet pan thus removing any concealed rim or water channel at the sides or front, where dirt or bacteria could hide. By specifying and installing Armitage Shanks Portman21 Rimless toilet pans in your healthcare building you are ensuring hygiene and patient safety are of primary concern.
17 Infection Control rinse water distribution for optimal hygiene WELS rated. Watermark approved.
18 17 Our solutions for Hospital and Care Facilities Accessible Basin The Armitage Shanks Portman21 Accessible basin is one of the best and most comfortable basins in existence today for less-abled and wheelchair users and also contains some real innovative design features. Developed using real-time feedback from less-abled people in focus groups across different regions, the Portman21 Accessible basin features truly ergonomic arm rests which are very important for seated users. Designed by Robin Levien RDI, the basin is not only aesthetically pleasing but with it s fully glazed underside and smooth contours it is very easy to clean and hygienic. Innovative features include: - Using anthropological data, the reach of thousands of different users was analysed and used to calculate the basin dimensions including the crucial tap handle reach which was then fully tested using model basins with different regional user groups. - Like many Armitage Shanks products the Portman21 Accessible basin has been developed using knowledge, experience, information gained from user trials and testing together with the input of relevant experts. ARMITAGE SHANKS PORTMAN21 Tap handle reach fully researched and tested Basin available with different taphole and overflow configurations Comfortable arm rest Shallow basin depth and fully glazed underside provides comfort for seated users legs Grab handle incorporated into the underside of the basin allows users to pull themselves to the basin when seated in a wheelchair Flat front provides important seal between users and the basin helping to prevent splashes on clothes
19 Infection Control 18 Markwik21 built-in thermostatic shower with Armaglide 2 Handshower and Wall Bracket Using the latest safety conscience thermostatic technology the Markwik21 concealed shower provides fully tested and approved delivery of water to patients. Armitage Shanks was one of the first manufacturers World-Wide to use cycle valve technology which helps to ensure users always start off with cold-warm water first thus reducing the possibility of the water being too hot for users. By incorporating this technology into the Markwik21 concealed shower it provides maximum protection. Durability is crucial in all healthcare environments especially where cleaning is concerned. The all metal design including the wall shroud, helps to provide longevity and hygiene is not compromised. The TMV3 point-of-use thermostat helps to ensure the fully hot water can be delivered right up to the shower fitting - reducing the risk of Legionella and Pseudomonas. Special single function design to reduce mist and airborne bacteria Dual check valves supplied as standard THE ARMAGLIDE 2 HANDSHOWER The Armaglide 2 Handshower and Wall Bracket include single function flow without aeration to help reduce mist that can easily be breathed-in by users and so reduces the risk of breathing in bacteria directly into the lungs such as Legionella. Armaglide 2 also incorporates dual check valves as standard eliminating the possibility of potentially harmful back syphonage. Durable metal back plate Safe delivery of hot water using TMV3 thermostat Cycle valve (always starting with cold water) for added safety Clear hot/cold or warm identification that won t rub off Metal handle AS/NZS compliant. AS2345 (DZR) compliant. TMV3 compliant. Watermark approved. Approved by NSW Health.
20 19 Our solutions for Hospital and Care Facilities Circulation Space for DDA Bathrooms The Australian Standard AS1428. Design for Access and Mobility sets out the minimum design requirements for new building work, as required by the NCC (National Construction Code), to enable access for people with disabilities.
21 Infection Control 20 For each toilet pan the required unobstructed circulation space, from the floor to a height of 2000mm, is shown in Figure 1. Except for the following which are allowed to intrude into the circulation space: The toilet paper dispenser shall be located within the zone specified in Figure 2. Grabrails where a concealed or high-level cistern or flush valve is used; a continuous grabrail shall be provided across the rear wall and side wall nearest the toilet pan. Where a low-level non-concealed cistern or flush valve is used the grabrail shall be terminated at each side of the cistern. Basin limited to 100mm intrusion as shown in Figure 1. Hand dryers and towel dispensers. Soap dispensers, towel dispensers, hand dryers and similar fittings where provided, shall be operable by one hand and shall be installed with the height of their operative component or outlet not less than 900mm and not more than 1100mm above the plane of the floor and no closer than 500mm from an internal corner. Shelves shall be provided adjacent to the basin as a vanity top at a height of 800mm to 830mm with a minimum width of 120mm and a depth of 300mm to 400mm without encroaching into the circulation space. Or as a separate fixture within the circulation space at a height of 900mm to 1000mm with a width of 120mm to 150mm and length of 300mm to 400mm. Alternatively, external to the circulation space at a height of 790mm to 1000mm with a minimum width of 120mm and minimum length of 400mm. Wall cabinets, where provided, shall not protrude more than 150mm into the circulation space and should be mounted at least 900mm above the floor level with the top shelf a maximum of 1250mm above floor level. Clothes hanging devices shall be installed 1200mm to 1350mm above the floor and not less than 500mm out from any internal corner. Portable sanitary disposal unit as shown in Figure 1. Other wall mounted fixtures such as dispensing units and sharps disposal units shall have a 900mm height clearance from the floor and a maximum projection of 150mm from the wall surface. For further information on the overlapping of circulation spaces please see the Australian Standard AS Positions of grabrails in water closets 1400 min. 900 to to Figure max. 200 to to max. Zone for position of toilet paper dispenser outlet to (FFL to top 480 of seat) 800 ± to 60 Circulation space for toilet pan 30 to min. 50 to min. 430 min. 600 max. 400 max. 50 to to min. 50 to 60 Distance varies with basin used 800 to to 150 Portable sanitary disposal unit 450 min. 600 min. 800 ±10 Figure ± to min min. Exclusion zone Exclusion line 450 to 460 C L pan 1400 min. Exclusion zone 50 to max. Cistern Grabrail continues where not obstructed by cistern (see Clause ) Exclusion zone 50 max. 300 min. 330 min. 100 max. permitted encroachment zone 600 min. 450 min. 800 to 810 LEGEND Figure 1 Circulation space line Figure 4
22 21 Our solutions for Hospital and Care Facilities A back rest shall be provided on accessible toilets. The back rest shall be capable of withstanding a force in any direction of 1100 N. It should have a height at the lower edge of the back rest to the top of the toilet pan seat of 120mm to 150mm as shown in Figure 5. The size of back rest itself should be between 150mm and 200mm high and 350mm to 400mm wide. The front edge of the centre of the back rest should be positioned to achieve an angle of 95 to 100 back from the seat hinge location. Back rest to be positioned between 0 and 50mm back from the seat bolt hole, as shown in Figure 6. Flushing controls, hand-operated or automatic hand-operated, should be used and located within the zone shown in Figure 7, or centred on the centre-line of the toilet completely within the verticle limits of the zone. The position of the control within this zone shall not be within the area required for grabrails or back rest. The flushing control should stand proud of the surface and activate the flush before the button becomes level with the surrounding surface. Water closet installation 600 min. Side wall 450 to 460 Alternative position on centre-line Zone for backrest max max. Figure C L pan 600 max. 400 max. Backrest 350 to 400 C L pan 500 max. Back wall Edge of any back-wall-mounted fixture or obstruction 150 to to 150 Top of seat 460 to min. Zone for position of flushing control Top of seat 460 to 480 Figure 5 Figure 6 Zone for position of flushing control 300 max. 600 min. Front of any back-wallmounted fixture or obstruction except backrest Angle of front of backrest Backrest position 0-50 from seat bolt hole Front of backrest 300 max. Side wall 600 min. 800 ± to to 100 Back wall
23 Infection Control 22 Basin for other than soleoccupancy unit - the projection of the basin from the wall and the position of taps, toilet pan and drain outlet shall be determined in accordance with Figures The water supply pipes and waste outlet pipes shall not encroach on the required clear space under the basin. The basin fixture and fittings are the only fixtures permitted in this space. Shelf space shall be provided adjacent to the basin in one of the following ways: As a vanity top: - At a height of 800mm to 830mm above the floor. - With a minimum width of 120mm beside the basin. - With a minimum depth of 300mm from the front to the rear wall. - With no encroachment into any knee and toe clearance space for a minimum width of 850mm centred on the basin. As a separate fixture: - Within any circulation space at a height of 900mm to 1000mm with a minimum underside clearance of 850mm for a width of 120mm to 150mm and length of 300mm to 400mm. - External to all circulation spaces at a height of 800mm to 1000mm with a minimum width of 120mm and a minimum length of 400mm. Wall basin installation - other than for sole occupancy unit 425 min. C L 120 to 150 Shelf Shelf 450 min. 300 to 400 Front of basin 300 max. to operable parts when handle is in fully open position Shelf to to 830 Circulation space min. 300 min. Knee / toe clearance 800 to to min. 200 min. 425 min. 850 min. C L Figure 8 Figure 9 Figure min.
24 23 Our solutions for Hospital and Care Facilities The Complete Range PORTMAN21 WALL BASIN 400MM Portman21 400mm Wall Basin No Overflow 1 Right Hand Taphole DN 32 Waste Hole Portman21 400mm Wall Basin No Overflow 1 Left Hand Taphole DN 32 Waste Hole Portman21 400mm Wall Basin 1 Centre Taphole with Overflow DN 32 Waste Hole Portman21 400mm Wall Basin No Taphole No Overflow DN 32 Waste Hole Versatile range of taphole and overflow configurations. - Right and left hand taphole options help reduce splashing and potentially harmful airborne bacteria. - Easy to clean design. - No overflow versions - great for clinical area use. PORTMAN21 WALL BASIN 500MM Portman21 500mm Wall Basin No Overflow 1 Right Hand Taphole DN 32 Waste Hole Portman21 500mm Wall Basin No Overflow 1 Left Hand Taphole DN 32 Waste Hole Portman21 500mm Wall Basin 1 Centre Taphole with Overflow DN 32 Waste Hole Portman21 500mm Wall Basin No Taphole No Overflow DN 32 Waste Hole Portman21 500mm Wall Basin 2 Taphole No Overflow DN 32 Waste Hole fixing bolt centres Versatile range of taphole and overflow configurations. - Right and left hand taphole options help reduce splashing and potentially harmful airborne bacteria. - Easy to clean design. - No overflow versions - great for clinical area use fixing bolt centres
25 Infection Control 24 PORTMAN21 WALL BASIN 600MM Portman21 600mm Wall Basin No Overflow 1 Right Hand Taphole DN 32 Waste Hole Portman21 600mm Wall Basin No Overflow 1 Left Hand Taphole DN 32 Waste Hole Portman21 600mm Wall Basin 1 Centre Taphole with Overflow DN 32 Waste Hole Portman21 600mm Wall Basin No Taphole No Overflow DN 32 Waste Hole Portman21 600mm Wall Basin 2 Taphole No Overflow DN 32 Waste Hole Versatile range of taphole and overflow configurations. - Right and left hand taphole options help reduce splashing and potentially harmful airborne bacteria. - Easy to clean design. - No overflow versions - great for clinical area use fixing bolt centres PORTMAN21 ACCESSIBLE WALL BASIN 600MM 280 Portman21 Accessible Wall Basin 600mm 1 Centre Taphole with Overflow DN 32 Waste Hole Portman21 Accessible Wall Basin 600mm 1 Centre Taphole No Overflow DN 32 Waste Hole Portman21 Accessible Wall Basin 600mm No Taphole No Overflow DN 32 Waste Hole Innovative grab handle incorporated into the under-basin design allows users to easily and efficiently pull themselves comfortably up to the basin. - Flat front design helps to provide a seal between the patient and the basin - thus avoiding embarrassing splashes. - Ergonomically designed for comfortable arm rest and tap use. - Shallow basin depth and fully glazed underside provides comfort for seated users legs. - Great for disabled use fixing bolt centres
26 25 Our solutions for Hospital and Care Facilities The Complete Range PORTMAN21 WALL BASIN 570MM WITH SHELF Portman21 Wall Basin 570mm No Overflow 1 Right Hand Taphole DN 32 Waste Hole Easy to clean design. - Shelf provides useful area. - Ideal for use in staff/public areas fixing bolt centres 280 fixing bolt centres fixing bolt centres 795 wall fixing 795 bolts wall fixing bolts wall fixing bolts PORTMAN21 BACK-TO-WALL RIMLESS 800MM TOILET SUITE Portman21 Pan Only Portman21 Pan with Seat (Pack) - With White Seat With Steel Blue Seat With Grey Seat Portman21 Back-to-wall Rimless Pan raised height 800mm projection Truly innovative patented rimless flushing provides ultra hygienic and efficient delivery of water. - Modern, easy to clean design. - WELS 4 star, 4.5/3 litre flush. - Average flush: 3.3 litres. - Great for disabled use outlet OD concealed bracket (supplied) ø55 ø outlet OD 110 concealed outlet bracket (supplied) 102 OD concealed bracket (supplied) ø55 295
27 Infection Control 26 PORTMAN21 SEAT Portman21 Toilet Seat - Steel Blue Portman21 Toilet Seat - Grey Portman21 Toilet Seat - White Available in 3 colours - Ideal for providing colour contrast for sight impairment. - Strong hinge design. - Complete with retaining buffers to help prevent sideways movement. - Ideal for disabled use - no cover to hinder wheelchair transfer. PORTMAN21 XL BACK-TO-WALL PAN Portman21 XL Pan and Seat White Portman21 XL Back-to-wall Pan Only Extra large toilet pan. - WELS 4 star, 4.5/3 litre flush. - Average flush: 3.3 litres. - Easy to clean design. - Great for Barriatric use. ø Portman21 XL Toilet Seat and Cover White Soft close mechanism. - Strong hinge design. ø ø
28 27 Our solutions for Hospital and Care Facilities The Complete Range HINGED SUPPORT RAIL 800MM Hinged Support Rail 800mm Toilet Roll Holder for Hinged Support Rail Rail is made from corrosion resistant aluminium. - Load tested to 200kg (downwards and sideways) - Toilet roll holder is designed for single handed use. - Anti-finger trap hinge design. - Designed to be easy to clean. - Friction hinge system helps to prevent rail dropping down
29 Infection Control 28 BACK REST RAIL AND CUSHION Back Rest Rail with Cushion Rail is made from corrosion resistant aluminium. - Loaded tested to 200kg. - Nylon fixation ends are included so rails do not require additional earthing. - Cushion is waterproof and fully sealed.
30 29 Our solutions for Hospital and Care Facilities The Complete Range MARKWIK21 WALL MOUNTED THERMOSTATIC SURGEONS SET Markwik21 Wall Mount Thermostatic Surgeons Set - Lever Operated with S Connectors TMV3 approved point-of-use thermostatic cartridge which is fully tested to some of the most rigorous of standards. - Removable spout, cartridge and body for easy autoclaving. - Unique patent pending BioGuard outlet - helping to reduce risk of Pseudomonas bacteria. - Easy to access and clean filters. - Cool body using Insulate Technology ½ male Ø ½ male 116 Ø Hydro Purge Kit Available for line cleansing when commissioning. 207 A6532AA Markwik21 Wall mounted mixer A6532AA Markwik21 Wall mounted mixer
31 Infection Control 30 MARKWIK21 HOB MOUNTED THERMOSTATIC SURGEONS SET Markwik21 Hob Mount Thermostatic Surgeons Set - Lever Operated TMV3 approved point-of-use thermostatic cartridge which is fully tested to some of the most rigorous of standards. - Unique patent pending BioGuard outlet - helping to reduce risk of Pseudomonas bacteria. - Removable spout, cartridge and body for easy autoclaving. - Easy to access and clean filters. - Cool body using Insulate Technology. Hydro Purge Kit Available for line cleansing when commissioning. MARKWIK21 THERMOSTATIC BASIN MIXER Markwik21 Thermostatic Basin Mixer with Copper Tails Basin mixer with extended easy use lever particularly suitable for closed fist operation. - Suitable for healthcare and less abled bathrooms. - Sequential operation. To ensure system hygiene and user safety the water is always drawn from first cold and the hot supply. - Can be fitted in standard taphole. BioGuard Outlet Available as an optional extra for greater protection against biofilm attachment.
32 31 Our solutions for Hospital and Care Facilities The Complete Range MARKWIK21 CONCEALED THERMOSTATIC SHOWER MIXER Markwik21 Built-in Thermostatic Shower Mixer TMV3 approved point-of-use thermostatic cartridge which is fully tested to some of the most rigorous of standards. - All metal back plate and handle for increased durability. - Clear hot/cold identification that won t rub-off. - Ultra safe and easy to use sequential lever mechanism. MARKWIK21 EXPOSED THERMOSTATIC SHOWER MIXER WITH HANDSHOWER OUTLET Markwik21 Exposed Thermostatic Shower Mixer TMV3 approved point-of-use thermostatic cartridge which is fully tested to some of the most rigorous of standards. - Clear hot/cold identification that won t rub-off. - Ultra safe and easy to use sequential lever mechanism.
33 Infection Control 32 MARKWIK21 EXPOSED THERMOSTATIC BATH MIXER WITH OUTLET Markwik21 Wall Mounted Thermostatic Bath Mixer TMV3 approved point-of-use thermostatic cartridge which is fully tested to some of the most rigorous of standards. - Ultra safe and easy to use sequential lever mechanism. - Clear hot/cold identification that won t rub-off. - Laminar flow to help reduce airborne water mist. ARMAGLIDE 2 HANDSHOWER AND WALL BRACKET Armaglide 2 Handshower and Wall Bracket Dual check valves included as standard eliminating the possibility of potentially harmful back syphonage. - Single function flow without aeration to help reduce potentially harmful mist. - Easy to clean hose and handset design - Complete with wall bracket. - WELS 3 Star, 9 Litres/Minute.
34 33 Our solutions for Hospital and Care Facilities Product Quality Guarantee 25 years all ceramic products 5 years showers, taps and mixers 10 years cartridges Armitage Shanks products are covered by the above product replacement warranties. For full warranty details visit Armitage Shanks pursues a policy of continuing improvement in design and performance of its products. The right is therefore reserved to vary specifications without notice. Colour reproduction is as accurate as possible within the limitations of the printing process. ARMITAGE SHANKS LTD 07/15
35 The Complete Range PORTMAN21 WALL BASIN 400MM No Overflow 1 Right Hand Taphole No Overflow 1 Left Hand Taphole Centre Taphole with Overflow No Taphole No Overflow MARKWIK21 WALL MOUNTED THERMOSTATIC SURGEONS SET Wall Mount Surgeons Set Hydro Purge Kit PORTMAN21 WALL BASIN 500MM No Overflow 1 Right Hand Taphole No Overflow 1 Left Hand Taphole Centre Taphole with Overflow No Taphole No Overflow Taphole No Overflow PORTMAN21 WALL BASIN 600MM No Overflow 1 Right Hand Taphole No Overflow 1 Left Hand Taphole Centre Taphole with Overflow No Taphole No Overflow Taphole No Overflow PORTMAN21 ACCESSIBLE WALL BASIN 600MM Centre Taphole with Overflow Centre Taphole No Overflow No Taphole No Overflow MARKWIK21 HOB MOUNTED THERMOSTATIC SURGEONS SET Hob Mount Surgeons Set Hydro Purge Kit MARKWIK21 THERMOSTATIC BASIN MIXER Basin Mixer BioGuard Outlet MARKWIK21 CONCEALED THERMOSTATIC SHOWER MIXER Shower Mixer PORTMAN21 WALL BASIN 570MM WITH SHELF No Overflow 1 Right Hand Taphole MARKWIK21 EXPOSED THERMOSTATIC SHOWER MIXER WITH HANDSHOWER OUTLET Shower Mixer PORTMAN21 BACK-TO-WALL RIMLESS 800MM TOILET SUITE Portman21 Pan Only With White Seat With Steel Blue Seat With Grey Seat PORTMAN21 SEAT Steel Blue Grey White MARKWIK21 EXPOSED THERMOSTATIC BATH MIXER WITH OUTLET Bath Mixer ARMAGLIDE 2 HANDSHOWER AND WALL BRACKET Handshower and Wall Bracket PORTMAN21 XL BACK-TO-WALL PAN Pan and Seat White Back-to-wall Pan Only Toilet Seat and Cover White HINGED SUPPORT RAIL 800MM Hinged Support Rail Toilet Roll Holder for Hinged Support Rail BACK REST RAIL AND CUSHION Back Rest Rail with Cushion
36 For your nearest Reece store call or visit Reece Onsite customers should contact their local Reece Onsite representative for all Commercial needs. Due to limitations in the printing process the colours in this brochure are a guide only. The manufacturer/ distributor reserves the right to vary specifications or delete models from their range without prior notification. The manufacturer/distributor takes no responsibility for printing errors. V1 [ ]
Concept Freedom Luxury Accessible Bathrooms
Ideal Standard (UK) Ltd The Bathroom Works National Avenue Kingston upon Hull HU5 4HS Tel: 01482 346461 Fax: 01482 445886 www.idealstandard.co.uk Ideal Standard (Ireland) 2nd Floor Unit 3013 Lake Drive
Planning Guide for Accessible Bathrooms AS1428.1-2009 including Amdt 1-2010, ambulant and complimentary items. Sydney Melbourne Brisbane Auckland
Sydney Melbourne Brisbane Auckland BACKRESTS RBA4150!SERIES BACKREST RBA4150!111 STAINLESS STEEL BACKREST RBA4150-101 Straight Arm Backrest RBA4150-201 Bent Arm Backrest Concealed mounting fl anges and
Carekit accessible toilet solutions
Carekit accessible toilet solutions Practical product packages to meet requirements for public accessible toilets WWW.ENWARE.COM.AU Carekits accessible bathroom solutions The Carekit range provides complete
CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System
CUBICLE SYSTEMS LTD CI/SfB 74 X IPS Pre-plumbed Wall Duct Access Panel System ISO 9001:2000 IPS the perfect washroom solution plumbing wall duct panel system and cubicles installed in one operation Cubicle
TOP 100 WATER SAVING PRODUCTS
TOP 100 WATER SAVING PRODUCTS The demands of modern living have seen water usage increase by 55% over the last 25 years, with 63% of all water used originating from bathrooms. As we use more and more water,
Quality is the one trend that never goes out of fashion. That s why Porcher continues to be the popular choice for mixers and tapware.
showers taps Quality is the one trend that never goes out of fashion. That s why Porcher continues to be the popular choice for mixers and tapware. After all, performance and good looks make an irresistible
Phoenix. Accessories
Phoenix Taps Showers Bath Outlets Accessories LISCIO Liscio mixers represent purity in design. Bold, vivacious styling that blends smooth lines with large surface areas to create a real sense of presence
604 Water Closets and Toilet Compartments
604 Water Closets and Toilet Compartments 604.1 General. Accessible water closets and toilet compartments shall comply with Section 604. 604.2 Location. The water closet shall be positioned with a wall
Base Cabinet with Self-storing Folding Doors and Floor
Usable Kitchens When designing a kitchen for use by persons with mobility impairments, especially those who use wheelchairs, careful layout of the kitchen is crucial to maintaining accessibility. People
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
Artisan Thermostatic basin mixer. Fitting Instructions & Contents List
Artisan Thermostatic basin mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts 1. Introduction Thank you for choosing Bristan,
All inclusive living.
All inclusive living. A range of innovative bathroom solutions alltm Transforming bathrooms since 1849 alltm designed with you in mind It s all about family life Young and old. Large and small. Able and
Bath Planning Guidelines With Access Standards
Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then
Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.
nursing homes. SPECIAL SOLUTIONS. Security and comfort for every stage of life. 401 Model: Eurotrend Care wash basin EN 32, DIN 18024-2 and 18025-2 11-96 (, EN 14688) 1 without overflow, pre-punched tap-hole,
Document M. MPacks. 195 www.ncdirect.co.uk. Compliance Information 196-199 Specialist Products 200-201
Document M solutions Document M Compliance Information 96-99 Specialist Products 200-20 MPacks Classic Blue Low Level 202-20 Classic Blue Close Coupled 20-20 Plus Pack Low Level 206-207 Plus Pack Close
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Britain s most popular bathroom. Plumbers Guide
ritain s most popular bathroom Plumbers Guide ontents uilding on a heritage you can trust 4 Putting more eco into economy 6 Residential collection 8 asins 8 W s 20 Flushplates 26 aths 28 rassware 32 Sandringham21
Hot water supply, distribution and use
Guidance Leaflet Reducing use Hot supply, distribution and use All businesses use hot in some way, whether for domestic use, in the manufacturing process or for ancillary activities. As there are considerable
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
CARE HOMES AND NURSING HOMES
Care Homes and Nursing Homes: This document provides guidelines and recommendations for cleaning care homes and nursing homes in the event of a disease outbreak in the vicinity. Cleaning and disinfection
Guidance Note on Flushing
Legionella and Building Services Flushing Conventional Showers Lessons Learned Guidance Note on Flushing Disclaimer Please note this article is for general interest and research purposes only and does
Chill 4 Hole Bath Shower Mixer
Chill 4 Hole Bath Shower Mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 02 2. Safety Note
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
Drainage and Grease Management for the Commercial Kitchen
Drainage and Grease Management for the Commercial Kitchen ACO. The future of drainage. The ACO system chain provides drainage solutions to meet the needs of tomorrow s food service facilities. Hostile
PRISLISTE SANITARY WARE FURNITURE WELLNESS FAUCETS ACCESSORIES. Veiledende forbrukerpriser gjeldende fra 01.01.2015
PRISLISTE Veiledende forbrukerpriser gjeldende fra 01.01.2015 2015 SANITARY WARE FURNITURE NO WELLNESS FAUCETS ACCESSORIES CONTENT Important information List of conventional signs II II SANITARY WARE Colours
Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.
Accessible Toilets This is an advisory statement reflecting current statutory and current best practice requirements. It offers guidance on best practice in designing environments not only to meet the
ADA Design Guide Washrooms & Showers
ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf Accessible Stall Design There are many dimensions to consider
WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:
WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose
MP 5.7 RESIDENTIAL SERVICES BUILDING STANDARD
MP 5.7 RESIDENTIAL SERVICES BUILDING STANDARD Index Purpose... 3 Commencement.3 Application...3 Compliance..3 Associated Requirements... 3 Definitions... 4 Kitchen Facilities... 6 Laundry Facilities...
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
CHILDCARE SETTINGS. Childcare Settings
Childcare Settings This document provides guidelines and recommendations for cleaning childcare settings such as nurseries, crèches and schools in the event of a disease outbreak in the vicinity. Cleaning
SHOWERS 85-100 SHOWERS
SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97
Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions
Close Coupled & Back To Wall WC Saintaryware Fitting Instructions Before starting any installation project please consider the following: Prior to drilling into walls, check there are no hidden electrical
The ADL Spa. Making daily living safer and more comfortable
The Making daily living safer and more comfortable Introducing the Independence meets safety, comfort and durability Designed in collaboration with universities and healthcare organizations, the ADL (Activities
Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts
Colonial Tap Range Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s leading
Thermostatic bar showers. Troubleshooting and maintenance
Thermostatic bar showers Troubleshooting and maintenance General Fault Diagnosis Outlet too cold Outlet too hot - Hot water supply must be 10ºC higher than desired mixed outlet for the mixer to operate
ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.
1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to
NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS
RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT
Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List
Artisan Thermostatic bath shower mixer Fitting Instructions & Contents List Please keep these instructions for future reference and request of replacement parts Contents Page 1. Introduction 03 2. Specification
Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom
ACCESSIBLE TOILET REQUIREMENTS Code 2007 o Where toilets are provided at every level of a building Accessible individual washroom or WC compartment can be provided Disadvantage If WC compartment is provided,
Prevention and control of infection in care homes. Summary for staff
Prevention and control of infection in care homes Summary for staff 1 DH INFORMATION READER BOX Policy Clinical Estates HR / Workforce Commissioner Development IM & T Management Provider Development Finance
Artisan Thermostatic Bath Shower Mixer
Artisan Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank you for choosing
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
Operators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
CONCEPT ThrEE shapes with infinite POssibiliTiEs www.idealstandard.co.uk
CONCEPT Three shapes with infinite possibilities www.idealstandard.co.uk 00 01 CONCEPT what s your style... Concept is where creative design meets practical solutions. Choose a style which appeals to your
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
CHECKLIST C ACCESSIBLE TOILETS CHECKLIST
CHECKLIST C ACCESSIBLE TOILETS CHECKLIST These guidelines relate to accessible toilets for use by visitors. Different considerations may apply where accessible toilets are to be used by employees. All
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
Thermo Siphon Solar Systems
Thermo Siphon Solar Systems Thermo Siphon Solar Systems are a very cost effective way of producing hot water due to their simplicity in design and installation requirements. Usually more common in hotter
XONYX Solid Surface Owner's Manual
XONYX Solid Surface Owner's Manual 1. IMPORTANT SAFETY CAUTION: Never allow children to use the bath/shower cabin without adult supervision to avoid accidents. CAUTION: Physically challenged people must
INSTALLATION INSTRUCTIONS MK-8704
INSTALLATION INSTRUCTIONS MK-8704 EXPOSED MACKINTOSH THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms
Chapter Seven: REQUIREMENT 7 Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms 7 PART A: Usable Kitchens 7a...covered multifamily dwellings with a building entrance on an accessible
Design Utility Lever Thermostatic Bath Shower Mixer
Design Utility Lever Thermostatic Bath Shower Mixer Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts General Information Thank
STABITHERM INSTALLATION & SERVICE BOOKLET
STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow
ACCESS AUDIT OF WESTPORT HOUSE
ACCESS AUDIT OF WESTPORT HOUSE Large sign on the highway to indicate the entrance to Purbeck District Council Large and wide entrance Entrance showing sign for opening times Entrance sign Main entrance
R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. R432-5-2. Purpose.
R432. Health, Health Systems Improvement, Licensing. R432-5. Nursing Facility Construction. R432-5-1. Legal Authority. This rule is promulgated pursuant to Title 26, Chapter 21. R432-5-2. Purpose. The
INSTALLATION INSTRUCTIONS BL-8704
INSTALLATION INSTRUCTIONS BL-8704 EXPOSED BLACK LEVER THERMOSTATIC MIXING VALVE WITH RISER KIT, HANDSET, LEVER DIVERTER, 8 ROSE AND ADJUSTABLE RISER PIPE BRACKET. Dimensions in Inches (& Millimetres) 1
Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual
Speedflow Undersink Unvented Water Heater Models SF10K and SF15K Instruction Manual Version 2.0 May 2009 Hyco SpeedFLOW UnVENTED WATER HEATER Models SF10K (10 Litres) and SF15K (15 Litres) 1. Introduction
Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012
Plumbing Code in Commercial Kitchens NH BOA May 9, 2012 Main Topics Grease Interceptors Indirect Waste Receptors Cleaning Chemical Dispensers Thermal Expansion IPC - Chapter 10 Traps Interceptors Separators
What makes Cederroth unique!
What makes Cederroth unique! Help within seconds! It is vital that you start rinsing the eyes within a few seconds after the accident has occurred. That is why Cederroth Eye Wash opens at the same instant
Innovative Hidden Storage Solutions
Innovative Hidden Storage Solutions Kitchen... Disposal of waste and recycling. Anti-bacterial, friction-fitted lid creates a seal against odours.* Buckets made from food grade, recyclable polypropylene.
Private Water Supplies Sampling Manual. A Field Guide
Private Water Supplies Sampling Manual A Field Guide Foreword This sampling manual details standard procedures for the collection, storage and transportation of samples at private water supplies in accordance
This section gives you some helpful information and tips on running your home and the equipment in it.
67 This section gives you some helpful information and tips on running your home and the equipment in it. Electricity Fuse board (electrical consumer unit) Make sure you know where your fuse board is and
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
SF15K SF05KSS, SF10KSS
Product Instruction Manual Speedflow SF05K, SF10K & SF15K SF05KSS, SF10KSS & SF15KSS Undersink unvented water heater V15.6/6 Version 3.2 Jan 2015 Thank you for purchasing a Hyco Speedflow unvented water
NEW. Teramo See Page 136
Basin NEW Teramo See Page 136 134 (INCLUDING COUNTERTOP BASINS) Looking for the perfect storage solution With the average bathroom getting smaller and more minimalistic in styling, bathroom furniture provides
Session 2: Hot Water Supply
MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:
Clinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Design guidance and considerations for a domestic accessible toilet/wetroom
WP01 / November 2015 Uniclass G44 CI/SfB74 Design guidance and considerations for a domestic accessible toilet/wetroom Using functional rooms, including the bathroom/going to the toilet, is the second
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
B150 Series Commercial Brewer. Direct Plumb Kit
B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer
SOUTH GLOUCESTERSHIRE COUNCIL SPECIFICATION REQUIREMENTS FOR WHEELCHAIR UNITS - DRAFT
SOUTH GLOUCESTERSHIRE COUNCIL SPECIFICATION REQUIREMENTS FOR WHEELCHAIR UNITS - DRAFT General This document details the design specification required by South Gloucestershire Council on Wheelchair Standard
GROHE Bathroom NEW GROHE EUROSMART FOR BATHROOM, KITCHEN AND COMMERCIAL MASTERS OF TECHNOLOGY
Bathroom NEW EUROSMART FOR BATHROOM, KITCHEN AND COMMERCIAL MASTERS OF TECHNOLOGY THEOCHARIS LIOLIS Master of Technology, produces unbeatable hardwearing tap surfaces with StarLight. MASTERS OF TECHNOLOGY
Compliance Guide. For Title III of the Americans with Disabilities Act
Compliance Guide For Title III of the Americans with Disabilities Act The use of the term ADA Compliant herein is a description of a class of product designs and is not intended as a substitute for your
FLUSHING CISTERNS. product catalogue
FLUSHING CISTERNS product catalogue 2 Beautiful power of water 5 CONCEALED SYSTEMS 23 FLUSHING PLATES 29 NO-CONTACT FLUSHING 35 EXPOSED FLUSHING CISTERNS 41 SPARE PARTS The line of concealed systems is
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
CONTINUOUS FLOW HOT WATER
CONTINUOUS FLOW HOT WATER THE RINNAI INFINITY STORY SO FAR... In the early 2004 s Rinnai launched the first fully electronic gas continuous flow hot water system in Malaysia. Appropriately named the Rinnai
TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER
TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER 1. BEFORE YOU BEGIN A. HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials, and
General food hygiene rules
General food hygiene rules Why food hygiene is important? Good food hygiene is essential to ensure that the food you and your family eats is safe. Poor hygiene procedures in your home can put you at risk.
The ADL Spa. from Best Bath Systems. Providing superior safety, comfort and durability in bath design
The ADL Spa from Best Bath Systems Providing superior safety, comfort and durability in bath design Designed in collaboration with universities and healthcare organizations The Activities of Daily Living
WC flushing cistern single or dual flush 0.13 0.05 2 to fill in 2 minutes WC trough cistern 0.15 per WC 0.10 2 Wash basin tap size 1 2
HAC_C0.qxd 7/4/08 9: Page 74 Chapter Pipe sizing Pipes and fittings should be sized so that the flow rates for individual draw-offs are equal to the design flow rates shown in table.. During simultaneous
SOUTH CAROLINA. Downloaded January 2011
SOUTH CAROLINA Downloaded January 2011 1401. General (II) B. When meals are catered to a facility, such meals shall be obtained from a meal service establishment graded by the Department, pursuant to R.61
Liquorice Kitchen Sink Tap
Liquorice Kitchen Sink Tap Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Contents Thank you for choosing Bristan, the UK s
Après Body Dryer for Wet, Shower and Bath Rooms Innovative, Energy Efficient, Safe, World Certified, Barrier Free Living and Independence
Après Body Dryer for Wet, Shower and Bath Rooms Innovative, Energy Efficient, Safe, World Certified, Barrier Free Living and Independence Key Features: Apres Body Dryer installed in walk in shower promoting
1501-04-04-03-01:2009 HELLENIC CHNICAL SPECIFICATION. 32176 ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common 2009-12-23 ICS: 93.
32176 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 2009-12-23 ICS 93160 1501-04-04-03-012009 H HELLENIC CHNICAL SPECIFICATION Sanitary ware common 10 313 111 45 ежглеяис тгс йубеямгсеыс (теувос еутеяо) 32177
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
World Leader in Emergency Eye Care
Emergency Eyewash 2013 CATALOG WHAT S INSIDE World Leader in Emergency Eye Care 115 Primary Eyewash Device 117 Secondary Eyewash Device 118 Personal Eyewash Bottles 119 Wall Stations 120 Refills 121 Accessories
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Plumbing Code in Commercial Kitchens
Plumbing Code in Commercial Kitchens City of Concord Code Administration 225-8580 Dan Clark Plumbing Inspector Tedd Evans, Chief Building Inspector Code References from the 2009 edition of the International
AT FIRST SIGHT Important informations
Technical catalogue AT FIRST SIGHT Important informations TIPS FOR USING THIS GUIDE Our new technical catalogue includes now all important information you will need for planing or call for tenders. Every
Itho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
PHOENIX TAPWARE. Gloss. Shower/Wall Mixer RRP: $264.00. Product Code: Available Finishes: GS780. Chrome MATCH WITH...
PHOENIX TAPWARE RRP: $264.00 Stylish Premium Chrome Finish Entire Range Available Phoenix Gloss Shower/Wall Mixer Product Code: Available Finishes: GS780 Chrome MATCH WITH... Click here to download HIGH
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Endless Hot Water 24/7
Endless Hot Water 24/7 Chromagen Continuous Flow Gas Water Heaters Live in eternal comfort with endless, efficient hot water from Eternity Get hot water on demand with an Eternity continuous flow gas water
LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION
LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION 1. Minimum Standards: This document sets out the minimum standards required in HMOs located within the London Borough
New or Remodeled Food Service Establishment Checklist**
ToTo Protect and Promote the Health and the Environment of the People of Kittitas County New or Remodeled Food Service Establishment Checklist** **Some items may not be required for limited food service