o Support for 16KB/32KB stripe sizes on Adaptec Series 7/8 controllers (maxview/arcconf/bios)
|
|
|
- Thomasina Perry
- 9 years ago
- Views:
Transcription
1 README.TXT Adaptec ASR-8405/ASR-8805/ASR-8885/ASR-8885Q/ASR-81605ZQ SAS/SATA RAID Controllers Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR-72405/ASR SAS/SATA RAID Controllers Adaptec ASR-6405/ASR-6445/ASR-6805/ASR-6805Q/ASR-6405E/ASR-6805E/ASR-6805E R5 SAS/SATA RAID Controllers Adaptec ASR-6405T/ASR-6805T/ASR-6805TQ SAS/SATA RAID Controllers AFM-700 Flash Backup Unit NOTE: All Adaptec by PMC products are UL listed and for use only with UL listed ITE. as of July 14, 2014 Please review this file for important information about issues and errata that were discovered after completion of the standard product documentation. In the case of conflict between various parts of the documentation set, this file contains the most current information. The following information is available in this file: 1. New Features in this Release 2. Software and Documentation 2.1 Driver & Utility Software 2.2 Documentation 3. Installation and Setup 3.1 Installation Instructions 3.2 SAS HD Cable Insertion 3.3 AFM-700 Flash Backup Unit Setup Supercapacitor Setup with Adaptec Series 6Q Controllers AFM-700 Cross-Controller Migration Status LEDs 3.4 Partition Setup 3.5 DKMS Driver Setup for Red Hat 6/CentOS Windows Setup 3.7 Solaris 11 Express Setup 3.8 SLES 11 Setup SLES 11 SP3 Inbox Driver Issues SLES 11 SP3 with 4KB/Sector Drives 3.9 Fedora Linux Setup 3.10 Debian Linux Setup 3.11 Ubuntu Linux Setup 3.12 Adaptec maxcache and maxcache Plus Setup 3.13 Dual Firmware Flash Image Support 3.14 Adaptec Flash Utility (AFU) Support 4. Known Limitations 4.1 Linux Boot Device 4.2 OS Installation with RAW Devices 4.3 Adaptec Series 6 Controller Issues 4.4 AFM-700 Flash Backup Unit 4.5 ATAPI Devices 4.6 System Compatibility Issues 4.7 Drive Compatibility Issues 4.8 RAID 50/RAID 60, Max Drives 4.9 Solaris 32-bit Array Size Limits 4.10 SLES 11 Boot Device Migration Issues 4.11 uefi BIOS Issues 4.12 BIOS Feature Disparity: Selectable Performance Mode 4.13 Simple Volume Support 4.14 Auto-Volume Mode Limitations 4.15 RAID 0 with Cache Preservation and 16K/32K Stripe 4.16 Force Rebuild in CTRL-A/uEFI BIOS 4.17 hdparm Support 4.18 HDA Mode Reset 1. New Features in this Release o Support for Adaptec ASR-8405 SAS RAID Controller o Support for 16KB/32KB stripe sizes on Adaptec Series 7/8 controllers (maxview/arcconf/bios) o uefi BIOS updates: - Set global or drive-specific physical drive write cache policy - Preserve the controller DDR cache - Set max link rate on Adaptec Series 8 controllers - Update CPLD from flash 1
2 NOTE: CPLD Update is for manufacturing purposes only. It is typically used by OEMs and System Integrators when building a new machine. For more information, contact Adaptec Support. o New controller mode on Adaptec Series 7/8 controllers (ARCCONF/BIOS): - Simple Volume mode (limits RAID type to Simple Volume only) o Native support for 4K sector drives on Adaptec Series 7/8 controllers NOTES: (1) Only uefi systems can boot from a 4K sector drive. 4K sector drives are not supported as a boot device with the Legacy (CTRL-A) Adaptec BIOS. (2) Support for 4KB logical sectors varies by vendor and OS version. For more information, see the Adaptec Knowledge Base at For information about Windows installation on 4K sector drives, see Section 3.6. o Bugfixes 2. Software and Documentation 2.1 Driver & Utility Software NOTE: You can download the latest versions of firmware, BIOS, driver software and utilities from the Adaptec Web Site at start.adaptec.com. o Adaptec Firmware/BIOS/Drivers/Utilities Version 1.06 o Adaptec maxview Storage Manager Version 1.06 Drivers for this release have been tested and certified on the following operating systems. You can load the drivers on out-of-box operating system versions, the latest service pack, or software update. Compatibility issues may be seen with untested OS versions. Microsoft Windows Drivers: o Windows Server 2012, 64-bit o Windows Server 2012 R2, 64-bit o Windows Server 2008 R2, 64-bit o Windows SBS 2011 o Windows 7, Windows 8, Windows 8.1, 32-bit and 64-bit Linux Drivers: o Red Hat Enterprise Linux 6.5*, 6.4, 5.10, IA-32 and x64 o SuSE Linux Enterprise Server 11, 10, IA-32 and x64 o Debian Linux 7, IA-32 and x64 o Ubuntu Linux 12, 11, 10, IA-32 and x64 o Fedora Linux 19*, 18, IA-32 and x64 o CentOS 6.4, 5.10 *RHEL 6.5 and Fedora Linux 19 are qualified with the OS inbox driver only. FreeBSD Drivers: o FreeBSD 9.2, 8.4 Virtual OS Drivers: o VMware ESX 4.1 o VMware ESXi 5.5 o Citrix XenServer 6.2 Solaris Drivers: o Solaris 10 U9 o Solaris 11 Express* *Not Supported on Bootable Arrays; see Section Documentation NOTE: You can download the latest documentation from the 2
3 Adaptec Web Site at start.adaptec.com. PDF Format (English/Japanese): o Adaptec SAS RAID Controllers Installation and User's Guide o Adaptec RAID Controller Command Line Utility User's Guide o maxview Storage Manager User's Guide o Adaptec SAS RAID Controllers Quick Start Guide (multi-language) HTML and Text Format: o maxview Storage Manager Online Help o Adaptec SAS RAID Controllers README.TXT file o maxview Storage Manager README.TXT file 3. Installation and Setup 3.1 Installation Instructions The Adaptec SAS RAID Controllers Installation and User's Guide contains complete installation information for the controllers and drivers. The Adaptec RAID Controllers Command Line Utility User's Guide contains complete installation information for ARCCONF. The maxview Storage Manager User's Guide contains complete installation information for the maxview Storage Manager software. 3.2 SAS HD Cable Insertion Be sure to orient external SAS HD cables correctly, prior to insertion on Adaptec Series 7/8 RAID controllers. With most standard implementations (Molex, Amphenol, FCI receptacles), it's possible to defeat the mechanical keying of the mini-sas HD plug connector system by turning the plug upside-down. 3.3 AFM-700 Flash Backup Unit Setup Supercapacitor Setup with Adaptec Series 6Q Controllers With Adaptec Series 6Q controllers, you must affix the supercapacitor module to the computer chassis with cable ties. The distribution kit does not include a mounting plate. For instructions, refer to the AFM-700 installation guide, available in the documentation section of the Adaptec Web site at start.adaptec.com. NOTE: The user's guide describes how to install the supercapacitor using the mounting plate method only. The instructions apply to Adaptec Series 7Q/8Q/8ZQ controllers and Adaptec Series 7/8 controllers with optional flash backup module AFM-700 Cross-Controller Migration Migrating the AFM-700 daughterboard/supercacpacitor module from one controller series to another is not supported in this release; eg, from an Adaptec Series 7 controller to Adaptec Series 8, or vice-versa Status LEDs The AFM-700 Flash Backup Unit includes three LEDs to help you monitor status. See the labels on daughterboard PCB for LED locations. LED 'DS2': Charger Enabled DS2 Solid on Charger Enabled DS2 Blinks Charger Off (during cap learn cycle) DS2 Temporary No Supercapacitor attached Blinks LED 'DS3': Supercapacitor power indication; Supercapacitor charge Bleeding LED LED 'DS4': Blinks faster when backup in progress 3.4 Partition Setup o Logical drives with >2TB of storage require GPT partitioning (GUID Partition Table) for OS installation or use as a data container. 3
4 NOTE: Windows creates MBR partitions (Master Boot Record), by default, which can address only 2TB of storage space. If the logical drive is >2TB, it is segmented into two partitions without warning, one up to 2TB, the other with the remaining disk space. Linux displays a pop-up message that the disk needs to be partitioned. o Before attempting to install an operating system in uefi mode, you must delete all MBR partitions from the disk or reformat the disk with GPT. The installation may fail if you try to install on a disk with a MBR partitioning scheme. See also Section DKMS Driver Setup for Red Hat 6/CentOS 6 Installation instructions for the pre-compiled DKMS drivers for Red Hat 6/CentOS 6 with Dynamic Kernel Module Support (DKMS) are provided in the RAID Controllers Installation and User's Guide. DKMS ensures that the driver remains installed across OS updates. You can download the pre-compiled DKMS drivers for Red Hat 6 and CentOS 6 at: NOTE: For DKMS driver instructions for other linux OSs, contact Adaptec Support or check the Adaptec Support Knowledgebase (ASK) at ask.adaptec.com. 3.6 Windows Setup o To successfully install Windows on a 4K sector drive in uefi mode, you must Refresh the screen after the driver is installed, then delete two extra partitions (created erroneously) before continuing: the 'Recovery' partition and the 'System' partition. Additionally, you cannot remove the USB driver disk until the installation completes. (If you remove the USB drive early, Windows displays a message saying that it could not continue to the next phase of the installation.) o When installing the driver on a Windows 2012 R2 system with two controllers installed (Adaptec Series 7 or Series 8) and at least one logical drive on each controller, the OS fails to detect the logical drives during installation. (The issue is not seen with only one controller.) WORKAROUND: Use the Windows inbox driver for installation, then update with the Adaptec driver after the installation completes. o When installing the driver on Windows SBS 2011 Essential, the installer times out before listing all discovered drives. The number of listed drives varies, depending on the drive type (eg, SAS vs SATA). This is a limitation in the Windows SBS installer; the Adaptec device driver detects all attached drives. 3.7 Solaris 11 Express Setup Installing Solaris 11/11.1 on a bootable array is not supported in this release. 3.8 SLES 11 Setup SLES 11 SP3 Inbox Driver Issues With SLES 11 SP3 (32-bit/64-bit), the inbox driver takes precedence over third-party drivers. As a result, the OS loads the inbox driver rather than installing from the Adaptec driver disk. WORKAROUND: To avoid loading the inbox driver (assuming you created a driver disk): 1. Boot from the SuSE installation DVD. 2. Add 'brokenmodules=aacraid dud=1' to the boot menu. 3. Press the F6 key to update the driver during installation. 4. Insert the USB driver disk. 5. On the 'Welcome screen', press CTRL+ALT+F2 to switch to the console, then type the following commands: # insmod./update/000/modules/aacraid.ko # rm -rf /etc/modprobe.d/blacklist /etc/modprobe.d/noload 6. Press CTRL+ALT+F7 to return to the installation screen and 4
5 continue the installation. 7. When the installation is 60-90% complete, press CTRL+ALT+F2 to switch back to the console, then type: # cp -a /update/install /mnt/tmp 8. Press CTRL+ALT+F7 to return to the installation screen and complete the installation SLES 11 SP3 with 4KB/Sector Drives 4KB/sector hard disk drives are not supported as a boot device with legacy (Ctrl-A) BIOS on SLES 11 SP3 (32-bit/64-bit). WORKAROUND: Install the driver in uefi mode. Follow these steps (assuming you created a driver disk): 1. Boot from the SuSE installation DVD. 2. Add 'brokenmodules=aacraid dud=1' to the boot menu: o Change from: linuxefi /boot/x86_64/loader/linux o Change to: linuxefi /boot/x86_64/loader/linux brokenmodules=aacraid dud=1 3. Press F10 to boot. 4. Insert the USB driver disk. 5. Complete Steps 5-8 in Section (above) to complete the installation. 3.9 Fedora Linux Setup To avoid a known PCIe Active State Power Management issue under Fedora Linux 14, you must add the OS option `pcie_aspm=off` in the GRUB bootloader file "menu.lst". Follow these steps: 1. When the first Fedora installation screen appears, press the 'Tab' key. 2. Before pressing the first 'reboot' button, edit grub/menu.lst: o Press Alt+F2 o cd /mnt/sysimage/boot/grub/ o Open the menu.lst file 3. Add 'pcie_aspm=off' just after 'rhgb quiet'. The new line should look like this: root (hd0,0) kernel /vmlinuz fc13.i686.pae... rhgb quiet pcie_aspm=off 3.10 Debian Linux Setup After installing the Debian Linux driver, you must replace the SCSI Device Partition Name in Debian s GRUB bootloader with a UUID. Failure to update the partition name may cause the system to hang when the OS is rebooted. In the GRUB bootloader file "menu.lst", replace the SCSI device partition name (for instance, /dev/sda1), with UUID=<string> Ubuntu Linux Setup o Due to a partition editor issue with Ubuntu , the OS reports an inaccurate drive size when creating a 4K sector boot drive in uefi mode. As a result, the installer hangs when creating the file system and the installation fails. WORKAROUND: Install Ubuntu LTS o When installing the driver on an existing Ubuntu 11 or 12 OS, the install script may stop at "grep vermagic" if the OS is already installed with Ubuntu-desktop packages. To avoid this problem, always install the driver packages first: # sudo dpkg -i aacraid ubuntu all.deb...then install Ubuntu desktop utilities by doing an online update: # sudo apt-get install ubuntu-desktop o After installing the Ubuntu driver, you must increase the SCSI command timeout value from 30 seconds (the default value) to 90 seconds. Failure to increase the timeout may cause the system to hang with an EXT4 error when a good drive is removed from a rebuilding array. Use these commands to increase the timeout in SYSFS, assuming /dev/sda, /dev/sdb, and /dev/sdc are the device LUNs on the Ubuntu Linux host: echo ``90``> /sys/block/sda/device/timeout echo ``90``> /sys/block /sdb/device/timeout echo ``90``> /sys/block/sdc/device/timeout 3.12 Adaptec maxcache and maxcache Plus Setup 5
6 o maxcache SSD caching is supported on Adaptec Series Q controllers only. maxcache Plus is supported on Adaptec Series 8Q/8ZQ controllers only. See the maxview Storage Manager Readme for maxcache Plus requirements and setup instructions. o The maximum number of SSDs that you can install on a controller for maxcache applications is: 8885Q/81605ZQ: up to 8 SSDs, with 2TB total capacity 7805Q/71605Q: up to 8 SSDs, with 2TB total capacity 6805Q/6805TQ: up to 8 SSDs, with 1TB total capacity See for a list of maxcache-compatible SSD drives Dual Firmware Flash Image Support Adaptec Series 7 and Adaptec Series 8 controllers support active and passive firmware images. Built-in logic determines the "right time" to update from passive to active, either at shutdown or boot up, and is designed to protect against image corruption or data loss due to power failure during image update. If the update occurs in the boot path, a server reboot is expected. Additionally, you must be running the latest drivers. NOTE: This feature is enabled only when upgrading from and to a firmware version that supports dual firmware images. For customers upgrading from an Adaptec release prior May 2013 (specifically, Firmware Version 7.2.0, Build 30260), there is no change in behavior. The firmware image is updated in one stage Adaptec Flash Utility (AFU) Support Adaptec Series 8 controllers do not support the DOS-based Adaptec Flash Utility (described in the user's guide). To flash a Series 8 controller, use the uefi BIOS, ARCCONF, maxview Storage Manager, or the maxview Storage Manager bootable USB image. 4. Known Limitations 4.1 Linux Boot Device Regardless of which device you select to install the OS, the boot record is always written to Device 0. As a result, Linux will fail to boot if you delete or swap away Device 0. For example, if you create three arrays in the BIOS--VOL-0, VOL-1, and VOL-2--install the OS on VOL-1, then swap VOL-0 and VOL-2, Linux will fail to boot. Restore the original array sequence and Linux boots normally. Ideally, you should always install on Device OS Installation with RAW Devices With Adaptec Series 7 and Adaptec Series 8 controllers, installing the OS in a mixed configuration with RAID Arrays and RAW devices is not supported. WORKAROUND: Remove the RAW devices, install the OS on the RAID array, then re-install the RAW devices. 4.3 Adaptec Series 6 Controller Issues The following issues are seen only with Adaptec Series 6 RAID controllers: o The Adaptec Series 6 controller driver does not implement the PCI suspend/resume function to support Linux Kernel Power Management. o Due to a PCIe configuration problem with ASUS Z9PE-D8 WS motherboards, Adaptec Series 6 controllers are not detected in slots with x8 links (eg, slots, 2,4,6). WORKAROUND: Use a slot with x16 links. o Hybrid RAID 10 logical drives (comprised of an equal number of SSDs and HDDs) are not built correctly in the CTRL-A BIOS; 6
7 the segment order is incorrect. WORKAROUND: Create the Hybrid RAID 10 in maxview Storage Manager or ARCCONF. 4.4 AFM-700 Flash Backup Unit Hot-plugging the AFM-700 supercapacitor module is not recommended. Doing so may result in unusual status updates, such as Preparing to Dead to Ready. 4.5 ATAPI Devices Adaptec Series 7 and Adaptec Series 8 controllers do not support ATAPI CD-ROM, DVD, or tape devices. 4.6 System Compatibility Issues o Supermicro X9 systems do not support a mixed configuration of Adaptec Series 7 and Adaptec Series 8 controllers. You can install only one controller type in these servers (Series 7 or Series 8). o With an Adaptec Series 7/8 controller connected to an ASUS P8B-M motherboard, the CTRL-A BIOS fails to load automatically after POST. WORKAROUND: Press ENTER to load the BIOS during POST. o Intel servers with BIOS version SDV.CP.B4.0 do not completely clear popup messages when there are multiple popups in a single operation in the uefi/hii interface. o With the HP StorageWorks D2700 enclosure, a maximum of 25 SAS drives or 24 SATA drives are supported. Slot 0 cannot be used with SATA drives. o Promise J630 and J830 enclosures are not supported in this release. o Discovery of Series 7 RAID controllers during system POST may be delayed in some PCIe Gen 3 systems, if link-up errors occur during PCIe link negotiation. These link-up errors occur rarely, and pose no risk of performance or data integrity issues. 4.7 Drive Compatibility Issues o OCZ Vertex 4 SSDs are not supported in this release. o With Seagate Constellation ES drives (eg, ST NS) with FW SN11, a medium error might result in SCSI command timeouts, depending on the I/O load. This condition might be seen when creating a logical drive with the 'build' initialization method. o With Hitachi HUA721050KLA330 hard drives, the drive LED blinks just once when using the CTRL-A BIOS 'Identify Drive' option. The LED blinks continuously if blinked from ARCCONF or maxview Storage Manager. o With HP LTO-4 Ultrium 1840 tape drives, backup fails with Adaptec Series 7 controllers. WORKAROUND: Upgrade the drive firmware to A63D using an on-board SAS or SATA controller, then try again. o With Tandberg LTO-4 tape drives, backup fails during longer write sequences with Adaptec Series 7 and Adaptec Series 8 controllers. The error is seen during writes in the 10GB-20GB range, causing the operation to be aborted. 4.8 RAID 50/RAID 60, Max Drives The maximum number of drives in a RAID 50 or RAID 60 differ between maxview Storage Manager, ARCCONF, and the BIOS: o BIOS and ARCCONF: 128 drives max RAID 50 - From 2-16 legs with 3-32 drives/leg RAID 60 - From 2-16 legs with 4-16 drives/leg o maxview Storage Manager: Assumes 2 legs for RAID 50/RAID 60 (non-selectable) RAID drives/leg (64 total) RAID drives/leg (32 total) 7
8 4.9 Solaris 32-bit Array Size Limits Due to an OS limitation in Solaris 32-bit systems, the practical limit for array size on Solaris 32 is 1TB. NOTE: If you create a >1TB array, OS tools, such as format or fdisk, won't detect them SLES 11 Boot Device Migration Issues By default, SuSE Linux uses the 'by-id' method to identify drives/partitions on the boot device. As a result, migration from one controller to another (eg, ASR-8885 to ASR-81605ZQ) fails because the original boot drive ID is not found on the new controller. WORKAROUND: Switch to the "by-uuid" method, then perform the migration. Step #1: Use the blkid command (built-in utility) to find the UUIDs of file systems sles11sp1boot:~ # blkid /dev/sda1: UUID="4512cf7d-4e22-4dfa dae41409" TYPE="swap" /dev/sda2: UUID="b144a0a2-b7fc-47fd-8459-ba40d0f663cd" TYPE="ext3" Step #2: (a) cd /etc (b) edit fstab file (c) Change the "by-id" names of file systems to their corresponding "uuid" names found in Step #1 Note: Make a backup of the fstab file before modifying it. Step #3: (a) cd /boot/grub (b) edit menu.lst file (c) Change the "by-id" names of file systems to their corresponding "uuid" names found in Step #1 Note: Make a backup of the menu.lst file before modifying it. Step #4: (a) Shutdown the SUSE system (b) Change the HBA/controller (c) Boot the system 4.11 uefi BIOS Issues o The uefi utility may become unresponsive after minutes of continuous use where you perform a large number of steps or continuously navigate through multiple screens (array creation, deletion, viewing array properties, etc.). WORKAROUND: Restart the server if uefi becomes unresponsive. o Using "FW Update from Media" and "Save Support Archive" in the same uefi session may cause the system to become unresponsive. WORKAROUND: Restart the server if uefi becomes unresponsive. o uefi-mode setup is not supported on Supermicro X9SCL-LN4F and X9DRi-F motherboards BIOS Feature Disparity: Selectable Performance Mode In the Legacy (CTRL-A) BIOS, the Selectable Performance Mode option is enabled for controllers operating in HBA Mode. This differs from maxview Storage Manager and ARCCONF, which disable Selectable Performance Mode if the controller is in HBA Mode Simple Volume Support In this release, you can create a maximum of 128 Simple Volumes in maxview Storage Manager, ARCCONF, or the BIOS Auto-Volume Mode Limitations Changing a controller into Auto-Volume mode (ARCCONF/BIOS) is not supported if the configuration includes any logical device type 8
9 other than Simple Volume, including a maxcache Container. The mode switch from RAID mode to Auto-Volume mode is blocked if any other type of logical volume exists (including maxcache). After switching to Auto-Volume mode, you can create and delete Simple Volumes only in maxview Storage Manager, ARCCONF, and the BIOS. NOTE: This behavior differs from previous releases (v1.05 and older), which supported other logical device types in Auto-Volume mode RAID 0 with Cache Preservation and 16K/32K Stripe In this release, creating a RAID 0 with 16K or 32K stripe size is not supported if cache preservation is enabled Force Rebuild in CTRL-A/uEFI BIOS With Automatic Failover disabled, Force Rebuild in the CTRL-A (Legacy) BIOS fails if you insert a new drive in place of a pulled member drive. (The logical drive rebuilds successfully when the same member drive is pulled and reinserted.) In the uefi BIOS, Force Rebuild fails in both cases: inserting the pulled member drive or inserting a new drive hdparm Support On Windows and Linux, the 'hdparm -i' command, used to set and view ATA hard disk drive hardware parameters, is not supported for direct-attached drives on Adaptec SAS controllers. Since 'hdparm -i' is designed for native libata/ide drivers, the command is working as designed and the behavior is expected. WORKAROUND: Use the 'hdparm -I' command instead HDA Mode Reset Adaptec Series 7 and Adaptec Series 8 controllers are reset using the HDA mode jumper on the controller board. If a HDA reset is required, contact Adaptec Support for assistance. (c) 2014 PMC-Sierra, Inc. All Rights Reserved. This software is protected under international copyright laws and treaties. It may only be used in accordance with the terms of its accompanying license agreement. The information in this document is proprietary and confidential to PMC-Sierra, Inc., and for its customers' internal use. In any event, no part of this document may be reproduced or redistributed in any form without the express written consent of PMC-Sierra, Inc., 1380 Bordeaux Drive, Sunnyvale, CA P/N DOC A Rev A 9
Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR-72405 SAS/SATA RAID Controllers AFM-700 Flash Backup Unit
README.TXT Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR-72405 SAS/SATA RAID Controllers AFM-700 Flash Backup Unit NOTE: All Adaptec by PMC products are UL listed and for use
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR-72405 SAS/SATA RAID Controllers Adaptec ASR-6405/ASR-6445/ASR-6805/ASR-6805Q/ASR-6405E/ASR-6805E/ASR-6805E R5 SAS/SATA
- Updated Linux drivers with improved performance and 'linux dd' support for RHEL and CentOS
README.TXT Adaptec ASR-8405/ASR-8805/ASR-8885/ASR-8885Q/ASR-81605Z/ASR-81605ZQ SAS/SATA AID Controllers Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR-72405/ASR-78165 SAS/SATA
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec maxview Storage Manager Adaptec Command Line Interface Utility (ARCCONF) as of December 4, 2012 Please review this file for important information about issues and errata that were discovered
readme.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-2045/ASR-2405 Unified Serial Controllers Adaptec ASR-5405Z/ASR-5445Z/ASR-5805Z
o Support for maxcache Plus caching and tiering software on Windows and Linux
README.TXT Adaptec maxview Storage Manager Adaptec Command Line Interface Utility (ARCCONF) as of November 22, 2013 Please review this file for important information about issues and errata that were discovered
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec maxview Storage Manager Adaptec Command Line Interface Utility (ARCCONF) as of May 2, 2013 Please review this file for important information about issues and errata that were discovered
o Support for setting the max link rate on Adaptec Series 8 controllers (maxview/arcconf/bios)
README.TXT Adaptec maxview Storage Manager Adaptec Command Line Interface Utility (ARCCONF) Adaptec maxcache Plus Command Line Interface Utility (MAXCONF) as of July 14, 2014 Please review this file for
README: maxview Storage Manager & ARCCONF Command Line Utility. DOC-01768-06-A Rev A1 Released Issue 1: November 24, 2015
. README: maxview Storage Manager & ARCCONF Command Line Utility DOC-01768-06-A Rev A1 Released Issue 1: November 24, 2015 Copyright 2015 PMC-Sierra, Inc. All rights reserved. The information in this document
-------------------------------------------------------------------- README.TXT. Adaptec Storage Manager (ASM)
README.TXT Adaptec Storage Manager (ASM) as of November 3, 2011 Please review this file for important information about issues and erratas that were discovered after completion of the standard product
-------------------------------------------------------------------- README.TXT
README.TXT ICP ICP9085LI/ICP5085BR SAS RAID Controller ICP ICP9047MA/ICP9087MA SATA RAID Controller ICP ICP9014RO/ICP9024RO SCSI RAID Controller ICP ICP5805BL/ICP5045BL/ICP5085BL/ICP5125BR/ICP5165BR Unified
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec ASR-4000/ASR-4800SAS/ASR-4805SAS RAID Controllers Adaptec AAR-2420SA/AAR-2820SA SATA RAID Controller Adaptec ASR-2130SLP/ASR-2230SLP SCSI RAID Controller as of October 20, 2006 Please
ASM_readme_6_10_18451.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 3, 2009 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of September 17, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product
MegaRAID SAS Device Driver Installation
MegaRAID SAS Device Driver Installation User Guide 80-00163-01, Rev. K 80-00163-01K Revision History Version and Date Description of Changes 80-00163-01 Rev. K, Updated the supported operating system versions.
MegaRAID SAS Device Driver Installation
MegaRAID SAS Device Driver Installation User Guide 80-00163-01, Rev. G Revision History Version and Date Description of Changes 80-00163-01 Rev. G, Added the Microsoft Windows 8 operating system (OS),
readme.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of August 11, 2010 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
readme_asm.txt -------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager as of March 27, 2006 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
NVMe SSD User Installation Guide
NVMe SSD User Installation Guide XS1715/SM1715/SM953 White Paper 2014 Samsung Electronics Co. SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products
Embedded MegaRAID Software
Embedded MegaRAID Software User Guide 48712-00, Rev. B Revision History Version and Date Description of Changes 48712-00, Rev. B, Revised the guide to document changes to the driver installation procedures,
SSD Guru. Installation and User Guide. Software Version 1.4
SSD Guru Installation and User Guide Software Version 1.4 Contents Welcome!............................................................................. 1 Key features.........................................................................
Intel Matrix Storage Manager 8.x
Intel Matrix Storage Manager 8.x User's Manual January 2009 Revision 1.0 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
RDX Compatibility Guide. Revision: 1.15 February 8, 2012
RDX Compatibility Guide Revision: 1.15 February 8, 2012 Backup Software Compatibility RDX products from Tandberg Data are supported by the backup applications listed below: Company Product Version Notes
SCSI device drivers are provided for the following operating systems: Microsoft Windows NT Server 4.0 Novell NetWare 5.1
This section describes how to install and configure the Dell small computer system interface (SCSI) device drivers included with your Dell PowerEdge 1400 computer system. These device drivers are designed
PARALLELS SERVER BARE METAL 5.0 README
PARALLELS SERVER BARE METAL 5.0 README 1999-2011 Parallels Holdings, Ltd. and its affiliates. All rights reserved. This document provides the first-priority information on the Parallels Server Bare Metal
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card
4 Channel 6-Port SATA 6Gb/s PCIe RAID Host Card User Manual Model: UGT-ST644R All brand names and trademarks are properties of their respective owners www.vantecusa.com Contents: Chapter 1: Introduction...
HP dx5150 RAID Installation and Setup Guide Version 1.10. Document Part Number: 403571-001
HP dx5150 RAID Installation and Setup Guide Version 1.10 Document Part Number: 403571-001 July 2005 Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject
-------------------------------------------------------------------- README.TXT
README.TXT Adaptec Storage Manager (ASM) as of June 7, 2007 Please review this file for important information about issues and erratas that were discovered after completion of the standard product documentation.
USB Bare Metal Restore: Getting Started
USB Bare Metal Restore: Getting Started Prerequisites Requirements for the target hardware: Must be able to boot from USB Must be on the same network as the Datto device Must be 64 bit hardware Any OSs
ExpressSAS Host Adapter 6Gb v2.15 Linux
Product Release Notes ExpressSAS Host Adapter 6Gb v2.15 Linux 1. General Release Information These product release notes define the new features, changes, known issues and release details that apply to
12Gb/s MegaRAID SAS Software
12Gb/s MegaRAID SAS Software User Guide Revision 2.0 DB15-001199-00 For a comprehensive list of changes to this document, see the History of Technical Changes. Corporate Headquarters Email Website San
Adaptec SAS RAID Configuration and the Windows OS Installation Instructions
Adaptec SAS RAID Confi guration and the Windows OS Installation Instructions Adaptec SAS RAID Configuration and the Windows OS Installation Instructions After all the hardware has been installed, you must
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family
Support Notes for SUSE LINUX Enterprise Server 9 Service Pack 3 for the Intel Itanium 2 Processor Family *5991-5301* Part number: 5991-5301 Edition: 3, E0406 Copyright 2006 Hewlett-Packard Development
PARALLELS SERVER 4 BARE METAL README
PARALLELS SERVER 4 BARE METAL README This document provides the first-priority information on Parallels Server 4 Bare Metal and supplements the included documentation. TABLE OF CONTENTS 1 About Parallels
RDX Compatibility Guide. Revision: 1.2.1 Oktober 21, 2013
RDX Compatibility Guide Revision: 1.2.1 Oktober 21, 2013 Backup Software Compatibility RDX products from Tandberg Data are supported by the backup applications listed below: Company Archiware Product P5
ThinkServer RS140 Operating System Installation Guide
ThinkServer RS140 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and Support
RDX Compatibility Guide. Revision: 1.2.5. September 25, 2014
RDX Compatibility Guide Revision: 1.2.5. September 25, 2014 Backup Software Compatibility RDX products from Tandberg Data are supported by the backup applications listed below (please click on company
Intel Rapid Storage Technology
Intel Rapid Storage Technology User Guide August 2011 Revision 1.0 1 Document Number: XXXXXX INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED,
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide
Dell PowerVault MD3400 and MD3420 Series Storage Arrays Deployment Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:
LSI Software RAID Configuration Utility
LSI Software RAID Configuration Utility E8581 First Edition August 2013 Copyright 2013 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in
SATA+Ultra ATA RAID CONTROLLER RC212. User Manual
SATA+Ultra ATA RAID CONTROLLER RC212 Contents Feature and benefits Package contents System requirement Magic Switch introduction and jumper setting Hardware installation Important message for user RAID
PCI Express SATA / esata 6Gb/s RAID Card User Manual
PCI Express SATA / esata 6Gb/s RAID Card User Manual Specifications : - 2 x SATA 6Gb/s Port (SATA version) - 2 x esata 6Gb/s Port (esata version) - Max. 6Gb/s transfer rate per port - Supports both SATA
Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines
Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines After all hardware has been installed, you must fi rst confi gure the Intel SATA HostRAID settings
HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers
Reference guide HP One-Button Disaster Recovery (OBDR) Solution for ProLiant Servers Reference guide Contents One button disaster recovery (OBDR) 2 Requirements 2 HP tape drive and server support 2 Creating
HP VMware ESXi 5.0 and Updates Getting Started Guide
HP VMware ESXi 5.0 and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi. HP Part Number: 616896-002 Published: August 2011 Edition: 1 Copyright
ThinkServer RD350 and RD450 Operating System Installation Guide
ThinkServer RD350 and RD450 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
Storage is in Our DNA. Industry-leading 12Gb/s and 6Gb/s Storage Solutions RAID Adapters, Host Bus Adapters, and SAS Expander
Storage is in Our DNA Industry-leading 12Gb/s and 6Gb/s Storage Solutions RAID Adapters, Host Bus Adapters, and SAS Expander 12Gb/s PCIe Gen3 RAID Adapters Series 8 and Series 8Q The Series 8 and Series
ITE RAID Controller USER MANUAL
ITE RAID Controller USER MANUAL 120410096E1N Copyright Copyright 2004. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated
RDX Compatibility Guide. Revision: 1.2.4. May 06, 2014
RDX Compatibility Guide Revision: 1..4. May 06, 014 Backup Software Compatibility RDX products from Tandberg Data are supported by the backup applications listed below (please click on company name for
RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2
RAID-01 (ciss) B.11.31.1005 mass storage driver release notes, edition 2 HP-UX 11i v3 HP Part Number: 5991-0448_ed2 Published: August 2010 Edition: 2 Copyright 2010 Hewlett-Packard Development Company,
SATA II 4 Port PCI RAID Card RC217 User Manual
SATA II 4 Port PCI RAID Card RC217 SATA II 4 Port PCI RAID Card This Manual is for many Models of SATAII RAID5 HBA that uses Silicon Image SATA II SiI3124 chipset: 1) 32bit PCI bus host card 2) 64bit PCI-X
M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual
Serial ATA and Parallel ATA Host Controller Rev. 0.96 December 03, 2003 Copyright 2003 ULi Electronics Inc. All rights reserved. COPYRIGHT NOTICE All information in this document is considered ULi Electronics
Intel ESB2 SATA RAID Setup Guidelines
Intel ESB2 SATA RAID Setup Guidelines Intel ESB2 SATA RAID Setup Guidelines After all the hardware has been installed, you must first configure Intel ESB2 SATA RAID Settings before you install the Windows
PCIe SATA 6G Raid Card
PCIe SATA 6G Raid Card User Manual Ver. 1.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2 Features...
Guide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation... 2 1.1 Serial ATA (SATA) Hard Disks Installation... 2 2. Guide to RAID Configurations... 3 2.1 Introduction
DataCenter 7280 3Gb/s SATA Host Adapter User Manual
DataCenter 7280 3Gb/s SATA Host Adapter User Manual Revision: 1.1 Date: May 2011 HighPoint Technologies, Inc. Copyright... 3 Trademarks... 3 HighPoint Technologies, Inc.... 4 Highpoint DataCenter 7280
RAID configuration and driver installation guide
Server systems and motherboards RAID configuration and driver installation guide For AP130-E1 5U Rackmount Server AP1720-E2 5U Rackmount Server NCCH-DL Motherboard PSCH-L Motherboard E1600 First edition
User Guide - English. Embedded MegaRAID Software
User Guide - English Embedded MegaRAID Software April 2015 Comments Suggestions Corrections The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize
The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.
SATA II PCIe RAID Quick Installation Guide Introducing the SATA II PCIe RAID The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled
NI Real-Time Hypervisor for Windows
QUICK START GUIDE NI Real-Time Hypervisor Version 2.1 The NI Real-Time Hypervisor provides a platform you can use to develop and run LabVIEW and LabVIEW Real-Time applications simultaneously on a single
USER S GUIDE. MegaRAID SAS Device Driver Installation. June 2009. 80-00163-01 Rev.D
USER S GUIDE MegaRAID SAS Device Driver Installation June 2009 80-00163-01 Rev.D This document contains proprietary information of LSI Corporation. The information contained herein is not to be used by
How To Install Acronis Backup & Recovery 11.5 On A Linux Computer
Acronis Backup & Recovery 11.5 Server for Linux Update 2 Installation Guide Copyright Statement Copyright Acronis International GmbH, 2002-2013. All rights reserved. Acronis and Acronis Secure Zone are
This user guide describes features that are common to most models. Some features may not be available on your computer.
RAID User Guide Copyright 2011 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation in the U.S. and other countries. Microsoft and Windows are U.S. registered trademarks
Support Notes for SUSE LINUX Enterprise Server 10 Service Pack 2 for HP Integrity Servers
Support Notes for SUSE LINUX Enterprise Server 10 Service Pack 2 for HP Integrity Servers HP Part Number: 5992-4774 Edition: E0708 Copyright 2008 Hewlett-Packard Development Company, L.P. Legal Notices
Embedded MegaRAID Software
Embedded MegaRAID Software User Guide 48712-00 Rev. A Revision History Version and Date Initial release of document. Description of Changes LSI, the LSI & Design logo, MegaRAID, and MegaRAIDStorage Manager
Rocket 750. 40-Channel SATA 6Gb/s PCI-Express 2.0 x8 HBA
Rocket 750 40-Channel SATA 6Gb/s PCI-Express 2.0 x8 HBA Quick Installation Guide v1.0 Dec. 17, 2012 1 Table of Contents HighPoint Rocket 750 HBA... 3 Kit Contents... 3 Board Layout... 4 Hardware Installation...
Intel Entry Storage System SS4000-E
Intel Entry Storage System SS4000-E Software Release Notes March, 2006 Storage Systems Technical Marketing Revision History Intel Entry Storage System SS4000-E Revision History Revision Date Number 3 Mar
NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later
NEC ESMPRO Manager RAID System Management Guide for VMware ESXi 5 or later 856-127900-613-G 7th Edition Jun. 2015 Copyright NEC Corporation 2015. Trademarks NEC EXPRESSBUILDER is trademarks of NEC Corporation.
BounceBack Server Solution Reference Guide
BounceBack Server Solution Reference Guide Contents Introduction... 2 System Requirements... 3 Initial Setup... 4 BounceBack Server Appliance Front View... 5 BounceBack Server Appliance Rear View... 6
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.
Embedded MegaRAID SATA User's Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter introduces
Acronis Backup & Recovery 10 Server for Linux. Update 5. Installation Guide
Acronis Backup & Recovery 10 Server for Linux Update 5 Installation Guide Table of contents 1 Before installation...3 1.1 Acronis Backup & Recovery 10 components... 3 1.1.1 Agent for Linux... 3 1.1.2 Management
HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation
HP User Manual for LSI Integrated RAID on HP xw4200/xw6200/xw8200/xw9300 Workstation LSI Integrated RAID controller and Host Bus Adapter... 2 Steps common to all methods for enabling LSI Integrated RAID...
ThinkServer RD540 and RD640 Operating System Installation Guide
ThinkServer RD540 and RD640 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual
5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75511R/VPMA-75511R) Operates... 1 1-1 SteelVine
Ultra ATA 133 RAID PCI Pro
Ultra ATA 133 RAID PCI Pro 1-1 Introduction Quick Installation Guide This ultra high-speed dual channel Ultra ATA/133 RAID controller is designed to support RAID 0, 1, 0+1 and JBOD. RAID configurations
How To Set Up Software Raid In Linux 6.2.2 (Amd64)
Software RAID on Red Hat Enterprise Linux v6 Installation, Migration and Recovery November 2010 Ashokan Vellimalai Raghavendra Biligiri Dell Enterprise Operating Systems THIS WHITE PAPER IS FOR INFORMATIONAL
How to Restore a Linux Server Using Bare Metal Restore
How to Restore a Linux Server Using Bare Metal Restore This article refers to firmware version 5.4 and higher, and the Barracuda Linux Backup Agent 5.4 and higher. Use the steps in this article to restore
RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009
RAIDCore User Manual P/N 83-00004638-12 Revision A December 2009 Copyright Protected Material 2009. All rights reserved. All other trademarks and registered trademarks are proprietary to their respective
SATA1.5G/ATA133 RAID Controller Card RC215 User Manual
SATA1.5G/ATA133 RAID Controller Card RC215 Features and Benefits Compliant with Serial ATA 1.0 specification Compliant with PCI Specification, revision 2.2 Provides three independent channels to connect
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering
3 Port PCI Express 2.0 SATA III 6 Gbps RAID Controller Card w/ msata Slot and HyperDuo SSD Tiering StarTech ID: PEXMSATA343 The PEXMSATA343 3-Port PCI Express 2.0 SATA Card with HyperDuo adds an internal
2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual
2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual www.vipower.com Table of Contents 1. How the SteelVine (VPMP-75211R/VPMA-75211R) Operates... 1 1-1 SteelVine
PCIe AHCI-IP Demo Instruction Rev1.0 10-Jul-15
PCIe AHCI-IP Demo Instruction Rev1.0 10-Jul-15 This document describes the instruction to show PCIeSSD demo by using SATA AHCI-IP, SATA-IP, and PCIeIP connecting with SATA-III/II SSD on Xilinx evaluation
Data Lifeguard Tools. Software Manual
Data Lifeguard Tools Software Manual WD Data Lifeguard Tools User Manual Information furnished by WD is believed to be accurate and reliable; however, no responsibility is assumed by WD for its use nor
Support for Storage Volumes Greater than 2TB Using Standard Operating System Functionality
Support for Storage Volumes Greater than 2TB Using Standard Operating System Functionality Introduction A History of Hard Drive Capacity Starting in 1984, when IBM first introduced a 5MB hard drive in
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures
Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures For Intel Server RAID Controller U3-1 and Intel Server RAID Controller U3-1L Revision 1.1 12/21/01 Date Rev Modifications 12/21/01 1.1
HP Embedded SATA RAID Controller
HP Embedded SATA RAID Controller User Guide Part number: 433600-001 First Edition: June 2006 Legal notices Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject
Windows Host Utilities 6.0.2 Installation and Setup Guide
Windows Host Utilities 6.0.2 Installation and Setup Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S.A. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
ThinkServer RD550 and RD650 Operating System Installation Guide
ThinkServer RD550 and RD650 Operating System Installation Guide Note: Before using this information and the product it supports, be sure to read and understand the Read Me First and Safety, Warranty, and
DriveClone Server. Users Manual
DriveClone Server Users Manual Contents Chapter 1: Introduction... 3 Chapter 2: Install and uninstall DriveClone Server... 3 2.1 System Requirement... 3 2.2 Installing DriveClone Server... 4 2.3 Uninstalling
QuickSpecs. What's New Support for HP MSA 2040 Storage. Models. HP Smart Array P712m Controller. Overview
Overview The HP Smart Array P712m mezzanine card is the preferred high value solution for 6Gb/s Shared SAS Storage for the HP ProLiant BladeSystem servers. It is one of the highest performing controllers
How To Manage Your Volume On Linux 2.5.5 (Evms) 2.4.5 On A Windows Box (Amd64) On A Raspberry Powerbook (Amd32) On An Ubuntu Box (Aes) On Linux
www.suse.com/documentation Storage Administration Guide SUSE Linux Enterprise Server 10 SP3/SP4 March 6, 2011 Legal Notices Novell, Inc. makes no representations or warranties with respect to the contents
AMD RAID Installation Guide
AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 8 / 8 64-bit / 7 / 7 64-bit / Vista TM / Vista
NVIDIA RAID Installation Guide
NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID. 2 1.2 RAID Configurations Precautions.. 3 1.3 Create Disk Array. 4 2. NVIDIA Windows RAID Installation
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server
System Storage DS3000 Storage Manager Version 10 Installation and Support Guide for Microsoft Windows Server, Linux, Novell NetWare, and VMware ESX Server System Storage DS3000 Storage Manager Version
RAID installation guide for ITE8212F
RAID installation guide for ITE8212F Contents Contents 2 1 Introduction 3 1.1 About this Guide 3 1.2 The Basics 3 1.2.1 What is RAID? 3 1.2.2 Advantages of RAID 3 1.2.3 Disadvantages of RAID 3 1.3 Different
Virtuozzo 7 Technical Preview - Virtual Machines Getting Started Guide
Virtuozzo 7 Technical Preview - Virtual Machines Getting Started Guide January 27, 2016 Parallels IP Holdings GmbH Vordergasse 59 8200 Schaffhausen Switzerland Tel: + 41 52 632 0411 Fax: + 41 52 672 2010
Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
Promise FastTrak 100-Lite RAID Controller
Promise FastTrak 100-Lite RAID Controller User s Manual Version 1.3, November 9, 2001 Copyright Copyright by Promise Technology, Inc. ( Promise ), XP. No part of this manual may be reproduced or transmitted