Water-Cooled SCREW Chiller
|
|
|
- Sarah Owens
- 9 years ago
- Views:
Transcription
1 INSTALLATION MANUAL Water-Cooled SCREW Chiller Please read this installation manual completely for safety before installing the product. The purpose of this manual is to keep the user safe and to prevent any property damage. After reading this installation manual, please retain it for future reference thoroughly. Installation work must be performed in accordance with this installation manual by authorized personnel only. Model : RCWW*******
2 2 For your records Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here: Model number : Serial number : You can find them on a label on the side of each unit. Dealer s name : Date of purchase :
3 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION 3 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION It can be dangerous when moving, installing and placing the system for its high pressure, electric devices and heavy weight especially when lifting the unit in a limited space(rooftop, lifted structure, etc.). Please read carefully the warnings and cautions on this manual and the labels attached on the unit, and follow the instructions. Please follow the following instructions to prevent any injury or property damage It may result in an injury or damages when neglecting the instructions on in this manual. The seriousness of the result can be classified as the following signs. Please note that any failure of system resulted by user s careless maintenance, natural disaster or the failure of the power cable shall not be warranted regardless of the warranty period. Please note that any part of this manual can be revised without notice for the product improvement.! WARNING It can result in serious injury or death when the directions are ignored! CAUTION It can result in minor injury or product damage when the directions are ignored The meanings of the symbols used in this manual are as follows.! Be sure not to do. Be sure to follow the instruction Warning Have all electric work done by a licensed electrician according to "Electric Facility Engineering Standard" and "Interior Wire Regulations" and the instructions given in this manual and always use a special circuit. - If the power source capacity is inadequate or electric work is performed improperly, electric shock or fire may result. Ask the dealer or an authorized technician to install the chiller unit. - Improper installation by the user may result in water leakage, electric shock, or fire. For re-installation of the installed product, always contact a dealer or an Authorized Service Center. - There is risk of fire, electric shock, explosion, or injury. Make sure to equip the circuit breaker and fuse. - Improper wiring or installation may cause fire or electric shock. Do not disassemble, repair or reconfigure the unit. - LG Electronics is not responsible for the any damage or loss from the arbitrary disassembly, repair or reconfiguration of the unit. Make sure to ground the unit properly. - There is risk of fire or electric shock. Do not store or use flammable gas or combustibles near the chiller unit
4 4 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION - There is risk of fire or failure of product. Do not reconstruct to change the settings of the protection devices. - If the pressure switch, thermal switch, or other protection device is shorted and operated forcibly, or parts other than those specified by LGE are used, fire or explosion may result. Install the unit on a foundation where the heavy weight can be supported. - Insufficient strength of the foundation to support the chiller operation may cause the unit failure or injury. Installing the product in small space requires separate measures to keep the leakage of the refrigerant within the safety limits in case of any leakage. - Consult the authorized dealer for appropriate measures to prevent the refrigerant leakage from exceeding the safety limits. The leakage of refrigerant exceeding the safety limit may result in dangerous situations due to the lack of oxygen level in the room. Securely install the cover of control box and the panel. - If the cover and panel are not installed securely, dust or water may enter the unit and fire or electric shock may result. Do not operate the unit arbitrarily. - Incorrect operation of the unit may cause dangerous situations such as unit defects, leakage or electric shock. Always consult the authorized dealer. Do not use damaged circuit breaker or fuse works correctly all the time. - It may cause fire, electric shock or injury. Keep the control panel from any water getting in. Do not wash the control panel with water. - It can cause electric shock or defects. When the product is soaked (flooded or submerged), contact an Authorized Service Center. - There is risk of fire or electric shock. Use a dedicated outlet for this unit. - There is risk of fire or electric shock. When installing and moving the chiller unit to another site, do not charge it with a different refrigerant from the refrigerant specified on the unit. - If a different refrigerant or air is mixed with the original refrigerant, the refrigerant cycle may malfunction and the unit may be damaged. Do not touch the power switch with wet hands. - There is risk of fire, electric shock, explosion, or injury. Ventilate before operating the chiller unit when gas leaked out. - Do not use a phone or operate the power switch at this time. It may cause fire or explosion. Do not put any heavy object on the top of the unit or climb on the unit. - It may cause defects or injury. Use fuse and circuit breaker with rated capacity. - Do not put your finger or a stick in the rotating part. It may cause injury. Use fuse and leakage breaker of rated capacity. - It may cause fire and defects. Redesigning the control box is prohibited. - Lock the control box with possible locking device and if you need to open the control box inevitably, turn off the main power first. Do not touch the wiring or a parts inside the panel. - It may cause electric shock, fire or defects. PRECAUTIONS BEFORE INSTALLATION Follow the permitted pressure level - Follow the regulated pressure for cold water, cooling water, refrigerant etc. Do not change the set values.
5 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION 5 - Do not change the set values of the controller and safety devices. Operating with inappropriate setting can cause damages. When changing the setting values, please consult with the specialist. Be careful of fire, earthquake and lightening. - In case of any natural disaster such as fire, earthquake or lightening, immediately stop operating the unit. If you continue to operate the unit, it can cause a fire or electronic shock. Follow all safety code. - When operate the chiller, follow the precautions on the manual, tag, sticker and label. Use of undesignated refrigerant and oil is prohibited. - Do not use undesignated refrigerant, freezer oil and brine. It may cause serious effect to the compressor and parts defect. During the installation and service, shut down the power supply. - Electric shock can cause injury and death. Mark and check all switches so that the power is not recovered until the work is completed. Wear safety equipment - Wear safety glasses and work gloves. Be careful when installing or operating the chiller and operating the electrical components. Always run fluid through heat exchangers when adding or removing refrigerant charge. - Potential damage of the tube within the heat exchanger can be prevented. Use Appropriate brine solution in cooler fluid loops to prevent the freezing of heat exchangers when equipment is exposed to temperature below 0 C. Do not vent refrigerant relief valves within a building. - Outlet from relief valves must be vented outdoors in accordance with the latest edition of ANSI/ASHRAE(American National Standards Institute/American Society of Heating, Refrigeration and Air Conditioning Engineers) 15 (Safety Code for Mechanical Refrigeration). The accumulation of refrigerant in an enclosed space can displace oxygen and cause asphyxiation. Provide adequate ventilation in enclosed or low overhead areas. Inhalation of high concentrations of refrigerant gas is harmful and may cause heart irregularities, unconsciousness or death. Misuse can be critical. Refrigerant gas is heavier than air and reduces the level of oxygen. It can cause irritation to eyes and skin. Be careful of water leakage. - In case of any water leakage in the pump or pipe, immediately stop operating the unit. It may cause electric shock, electricity leakage or defects. Be careful of electric shock. - Always ground the chiller during installation. It may cause electric shock. Do not leave refrigerant system open to air any longer than necessary. - If the repair cannot be completed, seal the circuits to prevent any contamination or rust within the product, and charge dry nitrogen. Do not reuse compressor oil. - It can damage the product Caution Installation Always check for gas(refrigerant) leakage after installation or repair of product. - Low refrigerant levels may cause failure of product. Do not install the unit where combustible gas may leak. - There is risk of fire or failure of product Keep level even when installing the product. - Unleveled refrigerant can cause problems to the product. Do not use the product for special usage or location such as preserving animal/plant, precision machine, artifact, etc. - It may cause property damage.
6 6 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION Use exclusive wire for the product. Use power cables of sufficient current carring capacity and rating. - It may cause fire and electric shock. When installing the unit in a hospital, communication station, or similar place, provide sufficient protection against noise. - The inverter equipment, private power generator, high-frquency medical equipment, or radio communication equipment may cause the chiller to operate erroreously, or fail to operate. On the other hand, the chiller may affect such equipment by creating noise that disturbs medical treatment or image broadcasting. To protect the product from corrosion, do not install the product where it is exposed to sea wind(salt spray) directly. If necessary, please install shield. - It may cause product deformation and defects. Make the connections securely so that the outside force of the cable may not be applied to the termianls. - Inadequate connetion and fastening may generate heat and cause fire. If the power cable got damaged, do not directly replace it, but call the service center for replacement first. Do not use the product in special environments. - Oil, steam and sulfuric steam can deteriorate the product performance or cause damage to the parts. Be careful when transporting the product. - When carrying the chiller, always consult with the specialized expert. When transporting the chiller, always follow the methods described in the manual. - If not, it can cause overturn, fall etc. Be sure the installation area does not deteriorate with age - If the base collapses, the chiller could fall with it, causing property damage, product failure, or personal injury. Be sure to dispose the packing materials safely. - Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear apart and throw away plastic packing bags so that children may not play with them. If children play with a plastic bag which was not torn apart, they face the risk of suffocation. Do not touch any of the refrigerant piping during and after operation. - Pipe during and after the operation can be hot or cold depending on the condition of the refrigerant flowing through the refrigerant pipe, compressor and refrigerant cycle parts. Touching the pipes at this time can cause burns or frostbites. Turn on the main power 12 hours before starting to operate the product. - If you operate the product immediately after turning on the main power, it can severely damage the internal parts. Keep the main power on while operating. Do not immediately turn off the main power after the product stops operating. - Wait at least 5 minutes before turning off the main power. If not, it may cause water leakage or other problems. Do not operate the product with the panel or safety devices removed. - Rotating parts or high temperature/pressure parts can cause safety accidents. Be careful when disposing the product. - When disposing the chiller, request to the specialized expert. Use a firm stool or ladder when cleaning or maintaining the chiller. - It may cause an injury. Be careful of high temperature. - Be careful not to make body contact to the parts of the chiller in high temperature. It may cause a burn. Be careful of high voltage. - Install separate wiring for the power and always install and use dedicated power supply and circuit breaker. It can cause electric shock and fire. Be careful of chiller installation. - Keep enough clearance around the product for service and especially for air cooling type, install the product at well ventilated location where there is no obstacle. Harsh chemical, household bleach or acid cleaner should not used to clean outdoor or indoor coils of any kind.
7 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION 7 - These cleaners can be very difficult to rinse out of the coil and can accelerate corrosion at the fin/tube interface where dissimilar materials are in contact. Use environment friendly cleaner. Be careful when restarting the product. - When a safety device is triggered, remove the cause and then restart the product. Repeating the operation arbitrarily can cause fire and defect. Use appropriate tools. - Use tools appropriate for the repair work and calibrate the measuring devices accurately before using. Using inappropriate tools can cause an accident. Be careful of sound and odor. - If you hear a weird sound or smell an odor, immediately stop operating the system and contact the service center. It may cause fire, explosion or injury. Be careful of injury. - Check the safety label of the safety device. Follow the above precautions and the contents in the label. It may cause fire and injury. To prevent the formation of the condensed water, the pipe connected to the evaporator as well as the evaporator itself should be well insulated. Check. - Perform periodic checks. If any problem occurs, stop the operation and contact the service center. Insufficient check may cause fire, explosion or error. Do not attempt to bypass or alter any of the factory wiring. - Any compressor operation in the reverse direction will result in a compressor failure that will require compressor replacement. Do not use jumpers or other tools to short out components, or bypass the parts differently from recommended procedures. - Short-circuiting the control board ground line with other wires can damage the electric module or electric components. Water must be within design flow limits, and should be treated cleanly. - This make it possible to ensure proper machine performance and reduce the potential of tubing damage due to corrosion, scaling, erosion and algae. LG Electronics is not responsible for any damage caused by cooling water not treated or improperly treated. Consult a water treatment specialist for proper treatment procedures. - Hard scale may require chemical treatment for its prevention or remove. Do not overcharge refrigerant to the system. - Refrigerant overcharging results in higher discharge pressure with higher cooling fluid consumption. Also it can damage the compressor and increase the power consumption. Also it can damage the compressor and increase the power consumption. Do not add different type of oil. - It may cause abnormal operation of chiller. Turn controller power off before service work. - It secures safety and prevents damage to the controller. Maintain the compressor oil pressure to normal level. - Use proper safety precautions when relieving pressure. Welding the evaporator head or nozzle part is not recommended. - If the part requires welding, remove the chilled water flow switch and entering/leaving fluid thermistors before welding. After the welding is completed, reinstall the flow switch and thermistors. Failure to remove these devices may cause component damage.
8 8 TABLE OF CONTENTS Thank you for purchasing the Water Cooled Screw Chiller of LG Electronics. Installation as instructed after reading this manual will ensure the safety, convenience and long lifetime of the unit. Please read this manual carefully for the correct installation and proper operation of the Screw Chiller unit. Once the installation completed, please run the commissioning and inspect according to the operating & maintenance manual. h This manual describes safety cautions for installation, general information, carrying and installation and wiring information of the Water Cooled Screw Chiller. TABLE OF CONTENTS 3 1. CAUTIONS FOR SAFETY _ WARNING/CAUTION Warning Caution 9 2. INTRODUCTION General Information System structure Nomenclature Name plate PREPARATION FOR IN- STALLATION Checking of the site information The environmental condition of installation site Securing service space Long term storage and proper place Condition for storage place Check points when storing chiller long term Check after long term storage PRODUCT RECEIPT Check item list and product condition Product inspection Product protection TRANSPORTATION Considerations for carrying in the product Transportation method Moving by crane Moving using roller INSTALLATION Requirements Unit Leveling Unit Isolation Isolation pad Cautions for the unit charged with refrigerant Things to check before moving and installation Cautions during carring and installation Cautions after installation Actions for refrigerant leakage PIPE INSTALLATION Considerations on connecting water pipes Bolt-tightening sequence for water piping connection Installing relief value and refrigerant vent line Installation based on High Pressure Gas Safety Control Act(varies by region/country law) Cautions in connection the refrigerant vent line Water treatment THERMAL INSULATION ELECTRIC WIRING Caution for electric installation Other cautions Power supply connection
9 2. INTRODUCTION 9 2. INTRODUCTION 2-1. General Information This manual describes the installation of water cooled screw chiller with X30 controller applied System structure Figure 1 shows the general parts location and components of the water cooled screw chiller. The location of control panel, type of waterbox, directions of inlet and outlet of the chilled water and cooling water and some pipes may vary by model or customer order. Please check the approved drawings for the details. * Prepare and check the approved drawing that fits the site. Front view Part Name Screw compressor 2. Relief valve for condenser 2 3. Relief valve for evaporator 4. Air vent for cooling water 8 5. Air vent for chilled water 6. Drain for cooling water 4 7. Drain for chilled water 8. Lifting hole(4 holes) for condenser 6 9. Lifting hole(4 holes) for evaporator Sight glass for evaporator 11. Control panel Starter panel 13. Flow switch (Chilled water) 14. Flow switch (Cooling water) Rear view 15. Temperature sensor (Chilled water outlet) 16. Temperature sensor (Cooling water outlet) Temperature sensor (Chilled water inlet) 18. Temperature sensor (Cooling water inlet) Sight glass for condenser Figure 1. General structure of screw chiller
10 10 2. INTRODUCTION 2-3. Nomenclature The model name of the screw chiller is as shown in Fig. 2. R : R-134a W : Water-cooled cooling only K : Water-cooled heat pump A : Air-cooled cooling only Compressor nominal capacity in Tons(usRT) 10RT RT RT RT 100 Cooling/chilled water maximum working pressures A : Chilled water 10kg/cm 2, Cooling water 10kg/cm 2 B : Chilled water 16kg/cm 2, Cooling water 16kg/cm 2 C : Chilled water 20kg/cm 2, Cooling water 20kg/cm 2 D : Chilled water 8kg/cm 2, Cooling water 8kg/cm 2 E : ETC R C W W 030 A A 1 1 C:Chiller 2-4. Name plate W : Screw compressor A : Flooded type B : Direct expansion type C : Falling film system M : Ice Storage High Efficiency R : Heat recovery N : Nuclear PJT, High Efficiency W : W type condenser V : V type Condenser S : Special Compressor quantity Development sequence order Figure 2. Nomenclature Name plate for the unit is attached on the control panel. General information of the chiller unit can be obtained from the plate and the information of the unit history can be used for quicker service. 1 Model name 2 Refrigerant 3 Cooling capacity 4 Power and current required for motor 5 Manufacture's serial number 6 Internal pressure test pressure 7 Maximum working pressure (Design pressure) 8 Volume of Evaporator 9 Volume of Condenser 10 Power electricity 11 Control electricity 12 Temperatures of Chilled water inlet/outlet 13 Temperatures of Cooling water inlet/outlet 14 Maximum pressure of chilled water and cooling water Fig. 3. Product plate
11 3. PREPARATION FOR INSTALLATION PREPARATION FOR INSTALLATION 3-1. Checking of the site information Before installing the chiller unit, check the site in advance, review the necessary details and coordinate the followings with the site personnel so that the installation can be performed safely and accurately. 1) Work scope and unit data: Check the site installation work scope and approved document 2) Installation location: Check the environmental condition to install according to the article ) Check the entrance size (width, length and height) to the installing site in advance not to have any trouble in moving. Then check and review the detail method and order for moving the unit The environmental condition of installation site The site space to install or store the product along with the following environmental condition should be considered. 1) Be careful not to damage the piping, insulation materials and wires of the chiller unit when storing and installing. The site should have ventilation measures for the refrigerant leakage. 2) Select site where the temperature is below 40 C all the time with good ventilation. When the unit is to be stored for long term, pay a close attention to the temperature of the site to be maintained below 40 C all the time. If the chiller unit is charged with refrigerant and the pressure of the unit exceeds the limit, the pressure relief valve will be operated and discharge the refrigerant gas resulting in the loss of refrigerant gas along with potential loss of lives. If the machine room temperature is over 40 C, the pressure vessel should be reconfigured. Check the set pressure for the relief valve of the chiller unit and maintain the room below the relief valve operating temperature consulting the authorized service engineer of LG Electronics. 3) Store the chiller unit in dry and safe location without any vibration. 4) The floor surface to install the chiller unit should be flat and of sufficient strength and mass to support the chiller operating weight. 5) Avoid place of any fire or flammable materials near. When installed in parallel to the heating object such as a boiler, sufficient care to the radiation heat is required. 6) Be careful with high humidity as it causes the electric error and the corrosion of the chiller unit. 7) Select the site where less dust are as the dust cause electric error. 8) Provide enough space around the unit to allow the installation and maintenance personnel access to all service points such as replacing heat exchanger tubes and waterbox to open. 9) Secure maximum or safe height to fit to the crane for easy lifting and lowering of the chiller unit. 10) Secure good drainage from the machine room. 11) Secure sufficient lighting considering the repair and maintenance. 12) This chiller unit is manufactured for indoor use. Therefore avoid installing outdoors or a place under direct sunlight. 13) Protect the unit by vinyl cover form dust and rains. 14) When installing the chiller unit, plan appropriately in accordance with the installation of High Pressure Gas Safety Control Act. (Local standard)
12 12 3. PREPARATION FOR INSTALLATION 3-3. Securing service space 1) Before installation, provide enough space for the service and maintenance as indicated on the foundation drawing. This is the minimum required space for the maintenance. 2) The foundation to install the chiller unit should be of sufficient strength and mass to support the chiller operating weight. 3) Prepare a good drainage path to drain out the chilled water and cooling water when cleaning the heat exchanger tubes or before shutting down. 4) To ensure stable operation of the chiller, level the chiller by adjusting the level plate within 1/16 5) Floor foundation construction is out of scope of LG Electronics. Please work according to the approved foundation drawings. LG Electronics is not responsible for any unit failure caused by the inappropriate design and construction of the foundation. Ceiling E UNIT Floor D: Reverse side A:Left side UNIT B:Right side Provide space at either side of heat exchanger for service of exchanging tubes. C:Front side Figure 4. Minimum space requirement for installation A B C D E RCWW008AA11~RCWW020AA11 1,500 2,500 1,500 1,500 1,000 RCWW020AA21~RCWW039AA21 2,500 2,500 2,000 1,500 1,500
13 3. PREPARATION FOR INSTALLATION Long term storage and proper place For long term storage, store and maintain the chiller unit at the following environmental condition irrelevant of before or after the installation Condition for storage place For long term storage, store at the environmental condition explained at 3-2. Once water pipes were connected to flow water, the chiller unit can be damaged by the evaporation of refrigerant occurring when there is a sudden drop of temperature or air temperature below freezing. Therefore drain out both of the cooling and chilled water completely, and purge with air additionally to remove all the water inside before storing. Cover the control panel and electric driving parts tightly with protective covers and keep the unit at safe and dry place without any vibration and sunlight exposure Check points when storing chiller long term Check item Check timing Check points Check chiller status Protecting electric parts Upon arrival at site Upon arrival at site Check the exterior of the unit for any damage or leakage of refrigerant. Check for any leakage on pipe connections, Cover up the control panel and control motor by vinyl cover tightly with a desiccant like Silica gel inside. For other electric systems, cover with vinyl to keep them from collecting dust. Periodic check Once a week Check for any damage or leakage on the piping connecting part visually. Check the pressure of the condenser. And record the changes in pressure level. In case of refrigerant leakage, take action according to the installation manual. If no refrigerant is charged, keep it charged with nitrogen in vacuum condition, and check the pressure level daily Check after long term storage 1) When operating after a long term storage of the unit, check the oil condition through sight glass along with any mechanical and electrical problem before operation. If any problem exists, have a LG engineer checked. If the unit has been stored long term, it is recommended to have the chiller unit checked by specialized service company. LG Electronics shall not be responsible for any issue occurred if it is not checked by LG Electronics or LG authorized service company. 2) If the unit has been left with no nitrogen pressure or no refrigerant for a long period, operate after the inspection by LG or a specialized service engineer. LG Electronics shall not be responsible for any issue occurred if it is not checked by LG Electronics or LG authorized service company. 3) Checking electric system Check for any defect on parts and wiring, and measure the resistance value of the motor insulation. About the checking procedure and judgment criteria, proceed according to the operation & maintenance manual. 4) Checking water system After long term shutdown of the unit, the chilled water/cooling water system is expected to have contamination from dust and inflow of external particles. Clean the water system and check the filter. Chilled water/cooling water system needs special care because it is generally an open type piping system. 5) Perform the commissioning according to the operation & maintenance manual.
14 14 4. PRODUCT RECEIPT 4. PRODUCT RECEIPT 4-1. Check item list and product condition Depending on the condition of the installation site, chiller is shipped as a single unit or as separated unit, and as charged with refrigerant or with nitrogen. If shipped as separated units, contact the authorized LG Electronics dealers or LG Electronics directly. 1) Shipment as single or separated unit For single unit type, the unit will be delivered to the site as preassembled. Separated unit type will be delivered as 2 or 3 separated main pieces. Confirm and record cthat it is the correct unit and that it is properly equipped as the invoice list especially for the shipment as separated. 2) Charged with refrigerant or nitrogen For single unit type, the unit will be shipped after charging refrigerant or nitrogen depending on the request from the customer. When refrigerant is charged, refrigerant and oil are charged together according to the specification of the chiller unit. It needs special attention to high pressure inside since the saturated refrigerant pressure is decided by the external air temperature. When nitrogen is charged, the unit is charged with 0.5kg/cm2 before shipment from the factory. If the pressure is 0, please record the condition and check for any leakage, since there is leak possibility Product inspection 1) Check all the components shipped are the same as in the delivery list. 2) Check the information on the product nameplate with the project information. Refer to article 2-4 for reading the nameplate in detail. 3) Check all exterior components for visible damage or leakage. Any apparent damage is found, first check whether the damaged part affects to safety (such as refrigerant leakage). Take photos of the damage and notify the LG service representative for service Product protection When the chiller unit is delivered, check and complete the following pre-commissioning checklist. 1) Before shipment from the factory, the chiller unit is charged with refrigerant or nitrogen to prevent corrosion by moisture penetration. Be careful not to open or operate the valves and connectors. The refrigerant inside can be leaked resulting an injury. If the water box is sealed with the flange, nitrogen is charged at the pressure 0.5 kg/cm2. Therefore first purge the nitrogen out and then open the flange. Caution) Never open service valve once nitrogen or refrigerant are charged. If the nitrogen is lost by the opening the valve, the chiller unit can be damaged. 2) When receiving the unit, inspect and record exterior components and pipes condition for any visible damage and leakage by loosened bolts. 3) If the unit is charged with refrigerant, check and record if oil is normally charged through the sight glass on the side of the compressor. If the oil level is not observed on the sight glass, contact the LG Electronics representative. 4) For any loss, damage or failure of parts, bring up the problem to the delivery personnel and contact the LG Electronics representative. Do not install the unit with damage without an approval from LG Electronics.! CAUTION Before unloading the chiller unit upon delivery to the site, check the condition of the unit for any damage during the transportation.
15 5. TRANSPORTATION TRANSPORTATION 5-1. Considerations for carrying in the product Before moving the unit to the site to install, check the size and weight of the chiller unit and whether the opening to the site is large enough. After checking the environmental condition of the site, prepare moving device and method appropriate for the heavy object. Secure the minimum required receiving dock space and be careful not to damage the unit when moving. The dimension on Table 1 is only a reference for the standard model. Check the approved drawing for actual dimension, and proceed the installation coordinating with LG Electronics or expert authorized by LG Electronics for the site condition.! WARNING If the disassembly of the unit is required to move to the site, the disassembly and reassembly of the chiller unit must be performed under the supervision of the LG Electronics or expert authorized by LG Electronics. If not, LG Electronics is not responsible for any issues occurring after. A B F C D E Figure 4 Product carring (Unit : mm) Length(mm) A B C D E F RCWW008AA11~RCWW012AA11 3,540 1,880 2,115 3,040 1,380 1,815 RCWW014AA11~RCWW016AA11 3,605 2,020 2,135 3,105 1,520 1,835 RCWW018AA11 3,605 2,020 2,285 3,105 1,520 1,985 RCWW020AA11 3,635 2,130 2,380 3,135 1,630 2,080 RCWW020AA21~RCWW022AA21 4,930 2,041 2,410 4,430 1,541 2,110 RCWW024AA21~RCWW028AA21 4,960 2,165 2,560 4,460 1,665 2,260 RCWW032AA21~RCWW039AA21 5,300 2,225 2,560 4,800 1,725 2,260 Note) Model (A): Standard model_chilled water inlet/outlet temperature 12 C/7 C, cooling water inlet/outlet temperature 32/37 C Model (B): Standard model_chilled water inlet/outlet temperature 10 C/5 C, cooling water inlet/outlet temperature 32/37 C Table 1. Minimum carring dimension and product size
16 16 5. TRANSPORTATION Product weight Following weight data are for those of standard products from LG Electronics. The actual weight of the unit can be different per the site condition. Please refer to the weight and size of the chiller unit on the approved drawing. Table 2. Product weight (Unit : kg) Model Product Weight Operating Weight Compressor Weight RCWW008AA11 2,900 3, RCWW010AA11 3,300 3, RCWW011AA11 3,500 3, RCWW012AA11 3,800 4, RCWW014AA11 4,100 4, RCWW016AA11 4,600 5,000 1,099 RCWW018AA11 5,000 5,400 1,180 RCWW020AA11 5,500 5,900 1,215 RCWW020AA21 5,800 6,200 1,480 RCWW022AA21 6,400 6,800 1,620 RCWW024AA21 6,700 7,100 1,560 RCWW026AA21 6,800 7,300 1,700 RCWW028AA21 7,000 7,500 1,680 RCWW032AA21 7,300 7,800 2,198 RCWW037AA21 7,800 8,300 2,360 RCWW039AA21 8,200 8,700 2,430 Note) Model (A): Standard model_chilled water inlet/outlet temperature 12 C/7 C, cooling water inlet/outlet temperature 32/37 C Model (B): Standard model_chilled water inlet/outlet temperature 10 C/5 C, cooling water inlet/outlet temperature 32/37 C
17 5. TRANSPORTATION Transportation method Moving by crane The chiller unit should be moved by lifting at designated lift points only. Hang the hooks on the designated holes and wire cables to the hooks so that the load of the unit is centered and even leveled. Be careful not to damage any electric wires, main unit and attached parts of the chiller unit by the lifting cables. Use the rigging lug on the 4 lifting holes of the chiller unit as shown in the following figure. Be aware the following warning and cautions.! WARNING Balance the chiller unit when lifting it up. Secure minimum length of the cables. First lift up about 0.5m to test and check the even leveling of the unit. The cables must be capable of supporting the entire weight of the unit. Tilting in lifting and moving will give serious damage to the unit and failure to properly lift unit may result in death or serious injury.! CAUTION If the product is charged with refrigerant, be careful not to apply any impact to the unit during the rigging. Especially impact on pipes can cause leakage on connecting parts. Mount the steel spreader high enough not to damage compressor, electric panel, control panel, etc. Spreader Figure 5. Lifting up the product by a crane
18 18 5. TRANSPORTATION Moving using roller Make sure the opening to the site has additional clearance of 300mm or more from the maximum width and height of the chiller unit. The following figure shows how to use the roller for moving. Do not apply any impact to the unit. If damaged, repair may not be easy. The roller and supplementary struts are not included in delivery. The installer shall prepare the roller in consideration of the weight and size of the unit in advance. Be careful for safety especially when moving the unit by roller. TUBE Sheet BASE Transporting device (Roller) Select the transporting device of the frame Figure 7 How to use the roller
19 6. INSTALLATION INSTALLATION 6-1. Requirements 1) Provide enough space around the unit to allow installation, of attached equipment, wiring, piping and maintenance access. Check the level and strength of the foundation surface. For the part to lift the chiller, mounting, unit weight and operating weight, refer to the specification, dimension and foundation drawing of the unit. 2) Service clearance for the chillers varies by the model. Secure sufficient service clearance to provide service to the chiller. Refer to ) When installing multiple chillers in the same site, secure appropriate service clearance. 4) The following dimensions for the foundation are based on the standard model. Prepare concrete foundation base to fit the model to install checking the approved drawing. Table 3. Basic dimension (Standard) (Unit : kg) Length(mm) A B C D RCWW008AA11~RCWW012AA11 3,040 2,620 1,120 1,525 RCWW014AA11~RCWW018AA11 3,040 2,620 1,270 1,675 RCWW020AA11 3,040 2,620 1,440 1,845 RCWW020AA21~RCWW022AA21 4,310 3,880 1,280 1,685 RCWW024AA21~RCWW028AA21 4,310 3,880 1,440 1,845 RCWW032AA21~RCWW039AA21 4,310 3,880 1,490 1,895 CHILLER LEG PAD BASE PLATE LEVELING BASE PLATE Figure 7 Foundation dimension (Standard model)! WARNING Install at a place with sufficient strength and mass to support the chiller operating weight. If the strength is insufficient, the chiller can fall and cause damage and injury. Install at a place protected against wind and earthquake. The chiller can fall and cause injury from installation defect. When constructing the foundation surface, be especially careful with floor support strength, drainage for draining water from the chiller, piping and wiring.
20 20 6. INSTALLATION 6-2. Unit Leveling To ensure the refrigerant leveled and the reliability of the chiller unit, the chiller should be installed even leveled. Level the unit within 1/16 inch over its length and width considering all the direction front/back/left/right. ** How to ensure the unit leveled 1) Use the level gauge : For length direction, use the shell length direction or the base surface of compressor to level the unit. For width direction, level the chiller using the base surface of the unit. 2) Use the water head difference (Use transparent vinyl hose) : Use transparent vinyl hose and mark at same location from base on the pipe plate in both sides in length direction of the unit and fixate the vinyl hose. Add water and level the product by aligning the water levels. Width direction can be done in the same way Unit Isolation To minimize sound and vibration transmission through the building structure, install isolation pads or optional spring isolators under the chiller feet Isolation pad 1) Install the isolation pads under the chiller feet as shown in the following figure. Chiller BASE TUBE SHEET Base Isolation pad Figure 9 Isolation pad(standard) 2) Anchor bolts and spring isolator (Optional) When applying additional isolation using anchor bolts to the standard isolation pad, follow the installation guide on the drawing When applying spring isolator, the spring isolator recommended by LG Electronics should be used, and installed according to the LG Electronics guideline.! CAUTION Adjust the spring isolators after filling the pipes with refrigerant and water.
21 6. INSTALLATION Cautions for the unit charged with refrigerant For the chiller unit delivered after charging refrigerant, a special care is demanded as the following details. And follow the following precautions for any refrigerant leakage while carring, installing and after installation. LG electronics is not responsible for any equipment problems occurred by neglecting the cautions Things to check before moving and installation 1) Check for the ventilation system in the room to install. Without ventilation system, the leakage of refrigerant can cause serious injury or death from suffocation Cautions during carring and installation 1) Move the chiller unit after evenly leveled. Tilting or any impact to the chiller can cause the refrigerant to leak and damage the unit. Therefore special care is required. 2) When lifting the screw chiller, be careful with the wire not to get hooked on the valve and pipe of the screw chiller, etc. 3) When lifting up or lowering the screw chiller, be careful with the pipes and valves not to hit any column or obstacle. 4) Weight includes the weight of the charged refrigerant and oil on top of the weight of the screw chiller. Always take into consideration the extra weight Cautions after installation 1) During the work of the water pipe connection, vent line connection for relief valve and thermal insulation, be careful not to damage any valve and pipe of the chiller unit. 2) After connecting water pipes, be careful not to let hot water pass to the chiller. 3) For long term storage, please consult with the service agent. 4) Always operate the ventilation system. If the refrigerant leaks, it can cause shortage of oxygen Actions for refrigerant leakage 1) If the leaking part is clearly identified and can be handled without any risk, close the joints and valves before resolving the leakage. 2) If the leakage does not stop from the chiller and the chiller can be moved, move the unit to an open location without any risk to fully discharge the refrigerant. If it is impossible to move the screw chiller, open the installation room and adequately ventilate the room. 3) If the leakage is big, evacuate the area and limit the access to the area by putting ropes around the leaked location. Always wear a breathing device. 4) If the refrigerant goes into the eye, wash the eye immediately with clean flowing water for more than 15 minutes and then promptly consult the doctor. 5) If the refrigerant contacts skin, take off any wet clothes, shoes and socks to avoid any chance of frostbite. After taking first aid, promptly consult the doctor. 6) When highly dense gas is inhaled, immediately move to fresh air, cover with blanket to warm body, and take first aid. And then promptly consult the doctor.
22 22 7. PIPE INSTALLATION 7. PIPE INSTALLATION 7-1. Considerations on connecting water pipes Install the water pipes to chiller unit considering the following details. Water piping is not included in the scope of system delivery from LG Electronics. When installing the chiller, check if the considerations are appropriately applied. Load side Load side (Chilled water pump) Cooling tower Cooling tower (Cooling water pump) Stop valve Strainer Flexible joint Supplier Scope Thermometer Air vent Air vent Pressure guage Chilled water drain Stop valve Cooling water drain Figure 9 Piping to chiller unit (User installation scope) 1) Based on the outline drawiing (Installation drawing), install the inlet/outlet piping of the chilled water/cooing water. Always check the direction of inlet/outlet, the specification of connecting flanges and the pressure applied. 2) Separate support must be installed aside form that for the chiller so that the load and the vibration of the pipes of the chilled water and cooling water do not transfer to the evaporator and condenser. Also provide ample space for service. 3) Install strainer of 10 mesh or higher on the front side of the inlet pipe of the chilled water and cooing water, so that the heat exchanger tubes of the heat exchanger not to be blocked by sludge which cause pipe damage (Freezing or damage). 4) Provide a device on the outlet side of the chiller to control the flow of the chilled water and cooling water. 5) Provide a device to prevent pressure hunting which may cause malfunction to the flow switch of the chilled water and cooling water. 6) The waterbox must be easy to open to clean the heat exchanger tubes of the heat exchanger. Install the pipe connectors so as to be separated easily without interfering with other pipes when extracting the heat exchanger tubes. 7) Please avoid using a pump with 3,550/2,950rpm(60/50Hz) for chilled water and cooing water, since it is the rpm of the chiller motor, which possibly resulte in resonance. If unavoidable, install an anti-vibration device. 8) Install accurate thermometer and pressure gauge on the pipe to check the status of the chilled water and cooing water to the chiller. 9) Install air vent valve, drain valve and pipe in the chilled water and cooling water waterboxes. Also install automatic air vent valve on the pipe. 10) Use of inappropriate water can cause sediments, corrosion and scaling which can damage the chiller. Therefore check and manage the water quality as standard. LG Electronics is not responsible for any results from use of the water out of the guaranteed quality. 11) Install the discharge pipe of the relief valve.
23 7. PIPE INSTALLATION Bolt-tightening sequence for water piping connection The order of flange bolt tightening using flat gasket or O-ring is by diagonal line as shown in the following figure. Then turning 90 and by diagonal line again. If the flange connection is not tightened appropriately, it can cause refrigerant and water leakage. 1) Pipes flange bolt assembly : Refer to Figure 10. Tighten the bolts in the order of flange assembly at appropriate torque. Apply final force to fit the bolt and repeat for others. 2) Water box flange bolt assembly : Refer to Figure 11. First tighten the 12 bolts in the set order at appropriate torque. Then tighten the next 12 bolts in order at final torque. And then apply final torque to the first 12 bolts and the 12 bolts not yet tightened. Start from bolt number 1 and rotate clockwise around the flange. 4-Bolt Flange 8-Bolt Flange 12-Bolt Flange Water Box Covers Water Box Covers Figure 11. Flange bolt assembly order
24 24 7. PIPE INSTALLATION 7-3. Installing relief value and refrigerant vent line Relief valve is a device to prevent the chiller unit from high pressure. It discharges the refrigerant when the pressure is increased to set level by abnormally hot temperature in the room by fire or other. Install the refrigerant vent line to outdoors from the relief valve discharge Installation based on High Pressure Gas Safety Control Act (varies by region/country law) 1) When installing the chiller, discharging pipe must be guided from the relief valve to outdoor. 2) Refrigerant applied in this product is non-flammable and non-toxic Freon gas. Discharging pipe from the relief valve must be installed to a safe location on outdoor Cautions in connection the refrigerant vent line 1) When connecting the discharging vent line to the relief valve, do not apply excessive force so that the force does not transfer to the connecting part of the relief valve. Fixate the screws on the relief valve side using tools and then tighten the screws on reverse side. Leakage of refrigerant can cause the failure of the chiller unit. 2) When connecting the discharging vent line, connect the pipes perpendicular way as shown in the figure below for easy replacement of the relief valve. Scope of general contractor Flange or union Discharge pipe Safety valve Safety valve Figure 12. How to install the outdoor discharge line of the relief valve
25 7. PIPE INSTALLATION Water treatment If the chilled water/cooling water is not managed well, not only is the performance of the heat exchanger deteriorated from the scaling, but also the tube can be damaged from rusting and pitting corrosion. Also water can get inside the chiller to cause rusting, insulation and heating, leading to major accidents, which can require high cost and long time for recovery.! CAUTION Corrosion accidents are mostly affected by external factors and LG Electronics is not responsible for any issues caused by corrosion from the poor management of the water quality. Prevent any potential accident through adequate management. Scaling and corrosion have many causes and there is no single solution. Always manage the water quality adequately. Refer to the operation and maintenance/management manual for details on how to manage the water quality. Standard item Reference item Item ph(25 C) Electric conductivity (Ma/m)(25 C) (μs/cm) (25 C) Chloride ion (mgcl /L) Sulfuric ion 2 /L) (mgso4 Acid consumption (ph4.8) (mgcaco3/l) Total hardness (mgcaco3/l) Calcium hardness (mgcaco3/l) Ion silica (mgsio2/l) Iron (mgfe/l) Copper (mgcu/l) Sulfide ion (mgso 2 /L) Ammonium ion (mgnh4+/l) Residual chlorine (mgcl/l) Free carbon dioxide (mgco2/l) Stability index Cooling water system Circulation type Circulating water Below 80 (Below 800) Not detected Supplied water Below 30 (Below 300) Not detected Once through water Once through type Below 40 (Below 400) Not detected Chilled water system Circulating water (Below 20 C) Below 40 (Below 400) Not detected Supplied water Below 30 (Below 300) Not detected Corrosion Trend Scaling 6.5~ ~ ~ ~ ~8.0 ㅇ ㅇ Below 200 Below 50 Below 50 Below 50 Below 50 ㅇ Below 200 Below 50 Below 50 Below 50 Below 50 ㅇ Below 100 Below 50 Below 50 Below 50 Below 50 ㅇ Below 200 Below 70 Below 70 Below 70 Below 70 ㅇ Below 150 Below 50 Below 50 Below 50 Below 50 ㅇ Below 50 Below 30 Below 30 Below 30 Below 30 ㅇ Below 1.0 Below 0.3 Below 1.0 Below 1.0 Below 0.3 ㅇ Below 0.3 Below 0.1 Below 1.0 Below 1.0 Below 0.1 ㅇ ㅇ Below 1.0 Below 0.1 Below 1.0 Below 1.0 Below 0.1 ㅇ Below 0.3 Below 0.3 Below 0.3 Below 0.3 Below 0.3 ㅇ Below 4.0 Below 4.0 Below 4.0 Below 4.0 Below 4.0 ㅇ 5.0~7.0 ㅡ ㅡ ㅡ ㅡ ㅇ ㅇ ㅇ ㅇ ㅇ Note) (1) Name and unit of the items are based on KS MD100. (2) O sign within the table refers to the factor related to the corrosion or scaling trend. (3) Unit and value within the parenthesis show data based on the previous unit, for reference. (4) If the temperature is high (40 C or above), generally the corrosion rate becomes high especially for steel that directly contacts water without any protective coating. It is recommended to have an effective plan in for the water such as adding anti-corrosive additive or air removal process, etc. Table 8. Water quality management standard for chilled water/cooling water
26 26 8. THERMAL INSULATION 8. THERMAL INSULATION The standard chiller unit from LG Electronics is shipped from factory without thermal insulation. Install thermal insulation over the chiller unit before commissioning test after leakage test on the site. Thermal insulation work should follow the standard insulation guideline. Cautions for thermal insulation work 1) Make sure the operating parts (valves, handles, etc.) are not to be thermal insulated or not to be touched by thermal insulation material. 2) Make sure the fixing bolts for waterbox not to be covered by insulation material to be able to open the waterbox when cleaning the tubes in the Heat Exchanger. Also when working thermal insulation, consider the flanges of the water pipes as well as the waterbox to be easily detached. (Also install the flange for the water pipe so that it is easy to separate.) 3) Make sure the insulation material covering the service parts such as compressor and main pipe bolts area to be removed easily when overhaulling or in inspection service. 4) Make sure that thermal insulation material does not block the view of the sight glass. 5) Make sure the water temperature sensor and others to be remained accessible for service. 6) Use only thermal insulation materials with equal or higher in thermal conductivity and quality than those specified by LG Electronics. 7) Install the thermal insulation material firmly using adhesive and completely close the gap between insulation material and the insulating part so that air does not get in. 8) About the thickness and specification of the thermal insulation material follow the drawing of insulation approved by LG Electronics and the standard design condition is as follows. - Dry bulb temperature - Relative humidity 9) After the insulation, make sure not to expose to excessive sunlight or cause damage while working. Dew condensation may occur by the deformed or damaged part, and it should be reworked. Thermal Insulation work scope No. 1 Item Compressor motor (suction side) Insulation material and Thickness Rubber Insulation, More than t20 2 Compressor suction refrigerant pipe 3 Evaporator 4 Water box 5 Chilled water inlet/out nozzles 6 Low pressure liquid refrigerant pipe 7 Oil reclaim pipe 8 Refrigerant charging pipe Figure 13. Locations requiring thermal insulation
27 9. ELECTRIC WIRING ELECTRIC WIRING 9-1. Caution for electric installation! WARNING Be sure to have proper equipment grounding before connecting the power, and remove the grounds last when removing. Failure to do so may cause an electrical short or fire. For measurements, use appropriate measuring instruments. Failure to do so may result in injury or electric shock. Remove any tools and debris of wires, bolts and washers left after installation, inspection and repair. Failure to do so may result in injury, fire and damages.! CAUTION Only personnel familiar with operation and maintenance shall operate the control panel and starter panel. It may cause injury, fire, malfunction or damage. Do not weld around the cable connected to the main unit. It may cause fire and damage. Do not keep objects such as nuts and bolts inside the control panel and starter panel. It may cause malfunction and damage. Use the cable that meets the rate. It may cause fire and damage. Install the machine, control panel and starter panel in the area free of flammable substance. It may cause a fire. Do not let the supply voltage exceed the range described in the manual or related material. It may cause damage or malfunction. Connect the wire to the controller according to the circuit diagram. It may cause damage or malfunction. Do not store the product in frequent flooding or humid area. It may cause damage or malfunction. Do not use the control panel and starter panel outdoors. It may cause damage or malfunction.
28 28 9. ELECTRIC WIRING Inspection Inspect the parts or controllers attached on the chiller unit for any damage in transporting or moving process. Check the reserved parts and parts in separate package for any loss. Environment condition Check if the installation condition and environment are within the following criteria. Item Specification Remarks Motor power 380Vac,440Vac,3300Vac,6 600Vac User option Power frequency 50/60Hz User option Power constant 3Phase Control power 220Vac,1PH User option Controller power 20Vac,1PH,50/60Hz Storage temperature -10 C ~ 60 C Use temperature 5 C ~ 40 C Use humidity Surrounding environment Altitude/Vibration Controller contact point 25 C, 20% ~80%RH, No dew condensation No corrosive gas, flammable gas, oil residue or dust Above sea level 1000m or less - 5.9m/sec 2 (=0.6g) or less VAC, 3A or less load 2. Load connecting capability below of 30VDC, 0.3A - Zero-voltage A contact output Input capacity of Controller contact Zero-voltage contact point input - Power is connected from controller (20VDC, 10mA) - Do not connect power externally Instant power outage compensation Controller: 100mS or less Voltage fluctuation Rated voltage ±10%
29 9. ELECTRIC WIRING Other cautions Have a qualified licensed electrician by LG Electronics handle controllers and tools. Shutdown all the power before connecting power cables and control signal cables. Be aware the safety devices and their functions on this manual and keep the safety requirements. Be aware operation method, features and setting values of the system. Make sure not to leave any tools or parts on top or inside the control panel and the starter panel during the operation. Maintain the control panel and starter panel always clean. Do not open the protection covers of the control panel and the starter panel once power is on or the system is running. Do not to touch hot surface like heater. Do the periodic check on the signal connection parts, protective devices and structures. Consult an expert for any suspicious part or problems. Keep the panel doors closed for the controller and the starter panel during operation. Block every holes or pits with barrier completely to prevent short circuit by rats, snakes or insects. Keep the starter panel door closed unless required otherwise. Inspect the wiring and related devices after repair or parts change.
30 30 9. ELECTRIC WIRING 9-3. Power supply connection 3 phase motor power 1) Confirm that the starter nameplate ratings are compatible with the power supply characteristics and with the electrical data on the chiller unit nameplate. 2) If the starter panel enclosure must be cut to provide electrical access, exercise care to prevent metal debris from falling inside the enclosure. 3) Use copper(cu) conductors to connect the 3-phase power supply to the separate or single unit type starter panel. 4) Make sure that the incoming power wiring is properly phased. 5) Make sure that the power supply conduit does not interfere with the serviceability, nor with structural members and equipment. Remove debris inside the starter panel. Failure to do so may cause a short circuit or serious damages to the starter components.
31 9. ELECTRIC WIRING 31 Wiring diagram for starter panel - 1comp(RCWW AA11) ** Above drawing is for reference purpose only and can be changed for design improvement or based on the customer request. Therefore always refer to the approved drawing.
32 32 9. ELECTRIC WIRING Wiring diagram for starter panel - 2comp(RCWW AA21) ** Above drawing is for reference purpose only and can be changed for design improvement or based on the customer request. Therefore always refer to the approved drawing.
33 9. ELECTRIC WIRING 33 Wiring diagram for control panel - 1comp(RCWW AA11) ** Above drawing is for reference purpose only and can be changed for design improvement or based on customer request. Therefore refer to the approved drawing.
34 34 9. ELECTRIC WIRING Wiring diagram for control panel - 2comp(RCWW AA21) ** Above drawing is for reference purpose only and can be changed for design improvement or based on customer request. Therefore refer to the approved drawing.
35 Appendix 35 Appendix 1. Installation checklist Check before installation NO Check item Result Remarks 1 2 Do you have the approved drawings for the installation site? (Heat source flowchart, machine room diagram, foundation drawing, electric wiring diagram) Do you have overall process schedule for chiller installation and related construction work? (Check equipment carring and pipe connection schedule) 3 Have you check the size of the equipment receiving dock? 4 Have you made the plan for moving the system to the installation site? 5 6 Is the size and height of the system foundation appropriate? (Check machine room and drawings) Is there any obstacle in the installation space? (Horizontal pipe within machine room, etc.) 7 Is the product away from any heating device? Installation Check _ Chiller NO Check item Result Remarks 1 Have you checked the factory test report before shipment for the chiller unit? 2 Are the correct accessories related to the chiller received? 3 Have exterior damages or internal wiring problem during transportation been checked? 4 Is there any leakage after sealing the refrigerant? (Check refrigerant pressure) 5 6 Have the evaporator and compressor been insulated firmly? How about the thermal insulation work of other parts? Is the inlet/outlet directions of the chilled water/cooling water of the installed chiller in line with the drawing? 7 Is the chiller leveled evenly? 8 Is the vibration isolation pad installed? 9 Have the tightening elements solidly tightened as the specified torques? Appendix 2. Installation Check _ Piping NO Check item Result Remarks 1 Are all pipes installed and connected according to the installation guide? 7. PIPE IN- STALLATION 2 Are the pipe diameters and inlet/outlet of the chilled water and cooling water correctly connected? 3 Are the particles and air within the pipe removed and purged? 4 Is the water pipe for the chiller connected according to the drawings? (Strainer, flexible, balancing valve, pressure gauge, etc.) 5 Have the pipe, flange and valves been insulated firmly? ** Result: Good O, Poor: X, Not applicable: N/A
36 36 Appendix Installation Check _ Electricity NO Check item Result Remarks 1 Do the cables and accessories meet the specifications and dimensions in accordance to the drawing and specification? 2 Has the wire pipe been checked to make sure it is cleaned before inserting the wires? 3 Is the curved radius of the cable satisfactory to the regulation? 4 Has the cable sheath been peeled off properly and wired without damaging the conductor using proper tools? 5 When wire needs to be supported or tied, are the wires neatly arranged? 6 When external layer of the cable needs grounding, has it been grounded properly through appropriate connection? 7 Have the permitted wires within the pull box and joint box been arranged neatly? 8 Have all unused holes within the box been blocked appropriately? 9 Is there any wire within the wire pipe connected? 10 Is the connector appropriately flame resistant in appropriate size? 11 Are the wires color coded? 12 Have the wires well wired not to deteriorate electric resistance, insulation resistance and tensile strength? 13 Is the circuit tags appropriately attached based on the permitted method? 14 Is the insulation resistance of the wire measured after inserting the wire? After the installation and measurement completed, are the wire coatings and conductive materials appropriately protected to avoid damages? Is the clearance between high voltage cable and low voltage cable or low electricity cable in compliance with the standard? When the cable is inserted, did it comply with the standard of not using vehicle or other heavy equipment? 18 Is the cable inserting device used in the site approved? 19 Are appropriate accessories used for connecting the cable tray? 20 Are the support interval and material for the cable tray appropriate? 21 Are any sharp parts that can damage the cable removed? 22 Are the bonding and jumper installed at the connecting part of the cable tray installed? 23 Are the 2nd wiring construction (starter pane to control panel) cable connection terminals aligned? 24 Is the motor current signal wiring according to the drawing? 25 Are the chilled water/cooling water pump interlock cable wiring terminals aligned? 26 Has the control valve of the chiller unit been wired according to the drawings? 27 Is every terminal tightened well? ** Result: Good O, Poor: X, Not applicable: N/A
37 37 2. Torque specification for bolts tightening Flare part Type Tightening torque (N m) Union-Type Flare Type 1/ / / / Electrical wiring part Type Tightening torque (N m) M3 0.6 ~ 0.8 M3.5 1 ~ 1.3 M4 1.5 ~ 2 M5 3 ~ 4 M6 5 ~ 6 M8 12 ~ 15 M10 24 ~ 49 M12 41 ~ 100 M ~ 127
38
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
SYSTEM Inverter Air Conditioners
OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: [email protected] Website: www.kellogg-american.com
Unpackaging & Handling Be sure to carefully inspect the unit before accepting the shipment. If any damage has occurred document it with the trucking company immediately. Contact your Kellogg Distributor
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
Miami Heat Pump HP Series Installation Guide
CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
Disposal Manual. Mazda 6 Vehicle type GJ ( Vehicle type in VIN : JM* GJ ****** 100001~ ) Subject vehicle. July 2013. Mazda Motor Corporation
Capacitor( i-eloop ) Disposal Manual Subject vehicle Mazda 6 Vehicle type GJ ( Vehicle type in VIN : JM* GJ ****** 100001~ ) July 2013 Mazda Motor Corporation 1 Contents Ⅰ.Introduction Ⅱ.Recommendation
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION
May 2010 DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION GUIDELINES FOR PERMITS ASSOCIATED WITH THE REPAIR OF FLOOD DAMAGED HOMES AND BUILDINGS The Department of Codes and Building Safety
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
Instruction Manual. Image of SP-3015 & SP-3815. Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function
Important Safeguards READ ALL INSTRUCTIONS BEFORE USE. Instruction Manual Automatic Dispensing Hot Water Pot with Reboil Function Image of SP-3015 & SP-3815 SP-3015: 3.0L SP-3815: 3.8L SP-3017: 3.0L (Stainless
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Owner s manual. Free 5 year parts, 1 year labour gurantee Register your guarantee at www.dysonairblade.com
Owner s manual Free 5 year parts, 1 year labour gurantee Register your guarantee at www.dysonairblade.com Thank you for choosing to buy a Dyson Airblade MK2 hand dryer Dyson customer care Your hand dryer
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS HEAT-FLO HOT WATER STORAGE / BOOSTER TANKS MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST, 80-ST, 115-ST, 80-ST-C, 115-ST-C FOR SINGLE TANK INSTALLATIONS For
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells
Engineering Production Sales LEAD CRYSTAL Valve-regulated lead-crystal batteries Energy storage Cells User Manual www.axcom-battery-technology.de [email protected] Chapter 1: 1. Introduction
Ductless Split Air Conditioner
Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
ROOM AIR CONDITIONER INSTALLATION MANUAL
ROOM AIR CONDITIONER INSTALLATION MANUAL ( Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Flushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007
Service Guide Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines ORDER No: UN-SVG001A-EN DATE: October 9, 2007 Introduction This document defines American Standard and Trane s recommendations
ENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
Central Air Conditioner
Central Air Conditioner USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL AIR CONDITIONER NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME
Lithium Ion Battery Specifications
Lithium Ion Battery Specifications Type: Cylindrical Lithium Iron Phosphate Battery Mode: LFP-26650-3300 AA Portable Power Corp. Prepared by Checked by Approved by 1 . Product Specifications Type ------------
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101
GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101 By Jim VanderGiessen Jr, Pro Refrigeration Inc. There is a good chance your glycol chiller system is often completely forgotten about, until that dreaded day you
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
AIR CONDITIONER INSTALLATION MANUAL
FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring
BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
10 tips for getting more reliability from your air-conditioning system [reliability]
10 tips for getting more reliability from your air-conditioning system [reliability] A guide for installers, specifiers, contractors and architects February 2010 10 tips for getting more reliability from
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
