1 ELEKTRYKA 2011 Zeszyt 1 (217) Rok LVII Łukasz PUTZ, Ryszard NAWROWSKI Instytut Elektrotechniki i Elektroniki Przemysłowej. Politechnika Poznańska HIGHER HARMONICS ANALIZE IN LED DIODE LAMPS USED TO ILLUMINATION SCENERY Summary. The paper presents the use of electroluminescence diodes (LED). The structure and principles of operation of the diodes are presented. The paper shows positive and negative aspects of LED diode operation. Main part of the paper includes presentation of preliminary study of electroluminescent light sources taking into account generation of the higher harmonics. The results provided the plots of the voltage and current harmonics contents in the phase and neutral conductors. The characteristics obtained this way have been thoroughly analyzed. Keywords: higher harmonics, LED diodes LED lamps, operation of diodes, THD ratio ANALIZA WYŻSZYCH HARMONICZNYCH W LAMPACH LED UŻYWANYCH DO OŚWIETLENIA DEKORACYJNEGO Streszczenie. W artykule zaprezentowano zastosowania diod elektroluminescencyjnych (LED). Przedstawiono budowę oraz zasadę działania takich diod. Artykuł prezentuje także pozytywne i negatywne aspekty pracy diod LED. Część główną publikacji stanowi zaprezentowanie wstępnych badań na elektroluminescencyjnych źródłach światła w zakresie generacji wyższych harmonicznych. Na podstawie wyników pomiarów zostały sporządzone wykresy zawartości harmonicznych napięcia i prądu. Następnie dokonano szerokiej analizy uzyskanych charakterystyk. Słowa kluczowe: diody LED, działanie diod, lampy LED, współczynnik THD, wyższe harmoniczne 1. INTRODUCTION The electroluminescence diodes (i.e. LED Light Emitting Diodes) are modern light sources widely introduced to lighting industry. They replace traditional bulbs, halogens and fluorescent light sources for lighting homes. They are also used at outer illumination of buildings. The present automotive vehicles are as well provided with lighting diodes, inclusive of lighting the vehicle interior and the outer road lights. At present the
2 100 Ł. Putz, R. Nawrowski electroluminescent light sources are used in lighting of streets, replacing to growing degree the low and high pressure gas discharge lamps [7]. 2. THE LED DIODES DESIGN AND OPERATION The electroluminescent diodes are made in the form of a p-n junction composed of semiconductors of two types: the electron excess (N-egative) and electron defect (P-ositive) ones. The current flowing through the junction causes recombination of electrons that transit from the higher to basic energetic state. While passing to lower energetic state the energy excess is transformed into the electromagnetic radiation quanta that is observed as a light of the colour depending on the type of semiconductor used for the purpose. The design and operation of electroluminescent diodes are shown in Fig. 1 [1, 10]. Fig. 1. Design and operation of LED diodes [10] Rys. 1. Budowa i działanie diod LED [10] The diodes of cold colours (white, blue, green) are obtained by proper doping of four components: aluminum, gallium, indium, and nitrogen. The warm colours (red, orange, yellow) may be obtained similarly, replacing nitrogen with phosphor. Colour of the diodes affects the pattern of its voltage-current characteristics in the conduction direction, that approximates a silicon rectifying diode. Current conduction begins at various voltage values (Fig. 2) [1, 9]: V a silicon rectifying diode, V red diode, V yellow diode, V green diode.
3 Higher harmonics analize 101 Fig. 2. Voltage-current characteristics of LED diodes [9] Rys. 2. Charakterystyki napięciowo-prądowe diod LED [9] 3. INTRODUCTION FEEDING SYSTEMS OF LED LAMPS For proper operation of diode light sources an appropriate feeder is required. At present such feeders are based on specialized integrated systems. An example of a control feeding system based on the SP7600 integrated system from EXAR is presented in Fig. 3. Such controllers significantly improve the operation parameters of diode lamps, growing power efficiency and power factor. Simultaneously such a feedings have a better resistance to electromagnetic interference [3]. Fig. 3. LED feeder with Exar SP7600 integrated circuit [2] Rys. 3. Zasilacz LED z układem scalonym Exar SP7600 [2]
4 102 Ł. Putz, R. Nawrowski 4. THE CONCEPT OF HIGHER HARMONICS The term higher harmonics is assigned to sinusoidal voltage or current patterns the frequencies of which exceed the basic frequency (50Hz). The patterns superpose together resulting in distorting the basic sinusoidal shape. The k-th voltage (current) harmonics is defined as the ratio of multiplicity of the frequency of considered pattern to the basic sinusoidal frequency [7]: where: fk harmonic frequency, f1 basic mains frequency. Connection of nonlinear receivers to the power network results in distortion of the current pattern. On the other hand, the voltage drop occurring at the network impedance causes voltage distortion in the receiver connection point. The distorted voltage (current) disadvantageously affects other receivers connected to the same network, that, in consequence, is conducive to [4]: increase in active power loss in transformers and motors; perturbations in operation of power-electric security systems; wrong operation of electric power meters; overload of capacitor batteries; difficulties in electric arc extinction in case of earth shorting; additional heat loss in the supplying line. The distorted patterns of T period caused by the higher harmonics may be presented in the form of Fourier series expansion [6]: or where:
5 Higher harmonics analize 103 In order to appraise the degree of the pattern deformation the synthetic indexes are used, referred to as the distortion factors of the voltage or current harmonic distortion THDU and THDI (Total Harmonic Distortion), respectively [4]: where: U1 rms value of the basic voltage harmonic component, Uk rms value of further voltage harmonic components, I1 rms value of the basic current intensity harmonic component, Ik rms value of further current intensity harmonic components. 5. THE INVESTIGATE POSITION In order to find the level of higher harmonics generation emitted by the diode light sources used in housekeeping the LED diode from APOLLO Lighting has been tested. The tested diode is marked by manufacturer as LED-E27A12-WHT. It is a diode with a E27 screw-cap, supplied with alternate voltage 230V 50Hz and 1.2W power, white light emitting. The tests have been carried out in the Theoretical Electrical Engineering Laboratory of the Institute of Electrical Engineering and Industrial Electronics of Poznan University of Technology. For the measurement purposes a high class FLUKE 434/PWR Power Quality Analyzer of harmonic contents has been used (Fig. 4). It is a complete three-phase troubleshooting tool that measures virtually every power system parameter: voltage, current, frequency, power, energy consumption or power factor (cos φ), unbalance, and harmonics and inter-harmonics [8].
6 104 Ł. Putz, R. Nawrowski Fig. 4. The measurement diagram with Fluke 434 meter Rys. 4. Schemat pomiaru miernikiem Fluke 434 One can use Fluke 434/PWR meter to conduct energy consumption studies and electrical load analysis, and to perform power quality logging and analysis according to PN-EN From most important advantages of power quality meter it is possible to feature [8]: Captures events like dips and swells, interruptions and rapid voltage changes, based upon ½ cycle rms values; Auto Trend function gives a fast insight into changes over time; System Monitor function gives you an overview of power system performance. It also checks that incoming power complies to norm PN-EN limits or to user own custom specifications; Detailed, user-configurable long-term recording gives the MIN, MAX and AVG readings of different parameters on all phases. Averaging time can be selected down to 0.5 seconds (or 1 minute for 1 day s recording, 10 minutes for 1 week, 30 minutes for 1 month or more; Two groups of four channels: simultaneously measure voltage and current on all three phases and neutral; Auto Scaling function: easier trend analysis with automatic scaling of the vertical axis so user will always view the waveforms on a full display; Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at service entrance; Extensive data analysis: cursors and zoom can be used live while taking the measurements, or offline on stored measurement data; The stored measurements can also be transferred to Power Log software on the computer by the infrared port (safety connecting between computer and meter) and then widely analyzed. The meter enables measuring percent contents of particular harmonic components H (until the 50th one), the harmonic contents THD factor and voltage or current direct
7 Higher harmonics analize 105 component (DC). Accuracy available in case of the FLUKE 434 analyzer reaches ±2.5 per cent in the measurement range 0 100% (for THD, DC, H1..H50) [8]. According to the norm PN-EN 50160, for the lighting equipment, total harmonic distortion factor for voltage (THD U ) can t exceed 8 percent. Instead for current total harmonic distortion THD I isn t clearly precise there are given acceptable levels each harmonics: second harmonic 2 percent, third harmonic 30 φ (power factor) percent, fifth 10 percent, seventh 7 percent, ninth 5 percent, eleventh to thirty ninth 3 percent [5]. 6. FINDINGS The measurement has been made for higher harmonics range. Other parameters of electric power have not been measured. The harmonics arising in the phase and neutral conductors have been separately recorded. Afterwards, the results obtained this way have been averaged in order to minimize the errors (Table 1) and, consequently, served for making the plots of percent contents of higher voltage and current harmonics, shown in Fig. 5 (the phase conductor) and Fig. 6. (neutral conductor). Analysis of the plots allows observing clear predomination of odd harmonics, both in case of voltage and current. The THD U factor is similar both for the phase and neutral conductors, being equal to 3.7 and 3.3%, respectively. It might be said that it is a satisfying value the pattern of actual voltage value is only slightly distorted as compared to the sinusoidal shape. The contents of constant component in the voltage pattern is quite insignificant (0.1 percent). The bigger attention turns the plots of harmonic contents of current intensity. Same as in case of voltage becomes visible the domination of odd harmonics. However the basic harmonic of the phase conductor is no longer dominating, because amounts 57,5 percent (for voltage it was 99,9 percent). In effect we have a large total harmonic distortion factor of current THD I = 59,3 percent. In the neutral conductor we can see the phenomenon of the current rectification. The curve of current intensity is widely deformed from the sinusoid (THD I = 90,3%), became straight the content of constant component amount 95,9 percent. One can declare that the stabilizing structure inside the LED lamp realize his role very well. However it influence wrong on the energetic network by the generating higher harmonics of current intensity and deform the current curve.
8 106 Ł. Putz, R. Nawrowski Component The higher harmonics contents measuring results Percent contents of THD factor, constant component DC and each harmonics (1 50) [%] Phase conductor L1 Neutral conductor N Table 1 Voltage U Current I Voltage U Current I THD 3,7 59,3 3,3 90,3 DC 0,1 23,7 0,1 95,9 1 99,9 57,5 99,9 4,8 2 0,1 16,3 0,3 1,8 3 2,5 22,2 2,2 1, ,4 0,1 1,6 5 2,5 13,3 2, ,3 0 1,8 7 0,9 7,9 0,9 1, ,9 0,1 1,7 9 0,5 6,1 0,3 1, ,9 0 1,4 11 0,2 6,8 0,2 1, ,8 0 1,6 13 0,4 6,4 0,3 1, ,2 0 1,7 15 0,5 6,1 0,3 1, ,5 0 1,4 17 0,1 6,2 0 1, ,8 0 1,9 19 0,2 4,7 0,1 1, ,1 0 1,7 21 0,2 4,9 0,1 1, ,1 0 1, ,2 0 1, ,9 0 1,7 25 0,1 4 0,1 1, ,2 0 1,8 27 0,1 4,3 0 1, ,3 0 1, ,1 0 1, ,5 0 1, ,6 0 1, ,6 0 1, ,2 0 1, ,6 0 1, ,3 0 1, ,8 0 1, ,2 0 1, ,9 0 1, ,4 0 1, ,1 0 1, ,9 0 1, , ,9 0 1, ,9 0 1, ,1 0 1, ,6 0 1, ,6 0 1, ,7 0 1, ,2 0 1, ,3 0 1,1
9 Higher harmonics analize 107 Fig. 5. Percent harmonics contents in the phase conductor Rys. 5. Procentowa zawartość harmonicznych w przewodzie fazowym Fig. 6. Percent harmonics contents in the neutral conductor Rys. 6. Procentowa zawartość harmonicznych w przewodzie zerowym
10 108 Ł. Putz, R. Nawrowski 7. SUMMARY The use of electronic systems with a view to stabilizing operation of the lighting diodes, apart from its many advantages has one important fault it generates higher harmonic component. The systems of diode lamps emit higher order harmonics to the network, giving rise to important hazard. This phenomenon would not be very significant without the fact that the electroluminescent lighting is more and more commonly used and may become soon a basic light source. In effect the distortion of voltage and current introduced to energetic network are more and more greater, causing increasing of the THD factor in points of the electrical energy distribution. It is necessary to use the special devices to reducing higher harmonics. It is also possible that using nonlinear elements, like LED lamps, will force the legislators to introduction of changes in the present norm PN-EN The tests referred to in the present paper only depict the scope of the knowledge on generation of higher harmonics by the electroluminescent light sources. The subject is very wide and requires further experiences and studies with the use of various types of the LED lamps [6]. BIBLIOGRAPHY 1. Collective Work: Technika świetlna 09. Poradnik Informator. Polish Lighting Committee of SEP. Warsaw Datasheet of EXAR SP7600 Integrated Circuit. 3. Gondek J., Kordowiak S.: Cyfrowe sterowniki hybrydowe LED. Materials of XIII Scientific Conference Computer Applications in Electrical Engineering. Poznan Lubierski K., Nawrowski R.: Badanie harmonicznych generowanych przez wyładowcze źródła światła. Materials of Conference Polish-Ukrainian School-Seminar. Jawor-Solina Polish European Norm PN-EN Putz Ł.: Generating higher harmonics in LED diode lamps used in housekeeping. Materials of XI International Conference Computational Problems of Electrical Engineering. Lazne Kynzvart Putz Ł.: Oświetlenie elektroluminescencyjne a emisja wyższych harmonicznych. Materials of XV Scientific Conference Computer Applications in Electrical Engineering. Poznan User Manual of FLUKE 434/PWR Power Quality Analyzer ( ) ( ).
11 Higher harmonics analize 109 Wpłynęło do Redakcji dnia 20 września 2011 r. Recenzent: Prof. dr hab. inż. Marian Pasko Omówienie W artykule zaprezentowano zastosowania diod elektroluminescencyjnych (LED). Przedstawiono budowę oraz zasadę działania diod oraz pokazano przykład układu stabilizująco zasilającego dla lampy LED. Artykuł prezentuje także pozytywne i negatywne aspekty pracy diod LED. W artykule przedstawiono także podstawy teorii wyższych harmonicznych oraz skutki ich działania. Część główną publikacji stanowi zaprezentowanie wstępnych badań na elektroluminescencyjnych źródłach światła w zakresie generacji wyższych harmonicznych. Do pomiarów użyto analizatora jakości energii Fluke 434/PWR. Źródłem światła, które wykorzystano do badań, była lampa LED firmy Apollo Lighting LED- E27-A12-WHT. Na podstawie wyników pomiarów zostały sporządzone wykresy zawartości harmonicznych napięcia i prądu. Następnie dokonano analizy uzyskanych charakterystyk.
Product Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
Neutral Currents in Three Phase Wye Systems
POWER SYSTEMS ENGINEERING DATA PUBLISHED BY SQUARE D, OSHKOSH, WISCONSIN Subject: Neutral Currents in Three Phase Wye Systems by Robert Arthur Square D Company Oshkosh, Wisconsin (414) 46-80 and R. A.
Power System Harmonics
Pacific Gas and Electric Company Power System Harmonics What are power system harmonics? Ideally, voltage and current waveforms are perfect sinusoids. However, because of the increased popularity of electronic
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES WHITE PAPER: TW0062 36 Newburgh Road Hackettstown, NJ 07840 Feb 2009 Alan Gobbi About the Author Alan Gobbi Alan Gobbi
POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS
A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS By: Robert G. Ellis, P. Eng., Rockwell Automation Medium Voltage Business CONTENTS INTRODUCTION...
Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution
Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution Nandita Dey, Dr.A.K.Chakraborty Lecturer, Electrical Engineering Department, Tripura University Suryamaninagar
Arc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
Survey of Harmonics Measurements in Electrical Distribution Systems
Survey of Harmonics Measurements in Electrical Distribution Systems Leon M. Tolbert, Member, IEEE Oak Ridge National Laboratory* P.O. Box 28, Bldg Oak Ridge, TN 3783-6334 Alexandria, VA 2235-3862 Phone:
Specification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka
Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka S S B Udugampala, V Vijayarajah, N T L W Vithanawasam, W M S C Weerasinghe, Supervised by: Eng J Karunanayake, Dr. K T M U Hemapala
Standards of Power Quality with reference to the Code of Practice for Energy Efficiency of Electrical Installations
Standards of Power Quality with reference to the Code of Practice for Energy Efficiency of Electrical Installations Ir. Martin WU Kwok-tin, Energy Efficiency Office, Electrical & Mechanical Services Department
Electromagnetic distortion test of renewable energy sources
ZESZYTY NAUKOWE WYŻSZEJ SZKOŁY ZARZĄDZANIA OCHRONĄ PRACY W KATOWICACH Nr 1(9)/2013, s. 5-14 ISSN-1895-3794 eissn-2300-0376 Tomasz Dróżdż University of Agriculture in Cracow, Faculty of Production and Power
The Basics of Digital Multimeters
IDEAL INDUSTRIES INC. The Basics of Digital Multimeters A guide to help you understand the basic Features and Functions of a Digital Multimeter. Author: Patrick C Elliott Field Sales Engineer IDEAL Industries,
LEP 4.4.07. Rectifier circuits
Related topics Half-wave rectifier, full-wave rectifier, Graetz rectifier, diode, Zener diode, avalanche effect, charging capacitor, ripple, r.m.s. value, internal resistance, smoothing factor, ripple
Harmonics in your electrical system
Harmonics in your electrical system What they are, how they can be harmful, and what to do about them Abstract Harmonic currents, generated by non-linear electronic loads, increase power system heat losses
Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems
Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems Introduction to Electro-magnetic Interference Design engineers seek to minimize harmful interference between components,
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
The electrical energy produced at the gen
300 300 Principles of Power System CHAPTER CHAPTER 12 Distribution Systems General 12.1 Distribution System 12.2 Classification of Distribution Systems 12.3 A.C. Distribution 12.4 D.C. Distribution 12.5
Section D..General Auto Electrical Corporation
43 Section D..General Auto Electrical Corporation 1. LED Based Signal unit GAEC manufacture LED based signaling system for use in electrified and non electrified sections of Indian railways. The exceptional
employed to ensure the continuing reliability of critical systems.
4 Regulations 1989, Regulation 4, places a duty on employers to provide safe systems for their workers: Regulation 4 of the Electricity at Work Regulations 1989 Systems, work activities and protective
Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12
Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
EXPERIMENT 1 SINGLE-PHASE FULL-WAVE RECTIFIER AND LINEAR REGULATOR
YEDITEPE UNIERSITY ENGINEERING & RCHITECTURE FCULTY INDUSTRIL ELECTRONICS LBORTORY EE 432 INDUSTRIL ELECTRONICS EXPERIMENT 1 SINGLEPHSE FULLWE RECTIFIER ND LINER REGULTOR Introduction: In this experiment
Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers
Journal Journal of of Emerging Emerging Trends Trends in in Engineering Engineering and and Applied Applied Sciences Sciences (JETEAS) (JETEAS) 1 1 (1): (1): 72-78 72-78 Scholarlink Research Institute
Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light
Hello and Welcome to this presentation on LED Basics. In this presentation we will look at a few topics in semiconductor lighting such as light generation from a semiconductor material, LED chip technology,
Electromagnetic Compatibility (EMC) Low-Frequency Standards. Standards on Low-Frequency Emission: IEC 61000-3-2
Electromagnetic Compatibility (EMC) Low-Frequency Standards Summary IEC 61000-3-2: Limits for harmonic current emissions (equipment input current 16A per phase) IEC 61000-3-4: Limitation of emission of
Study Guide for the Electronics Technician Pre-Employment Examination
Bay Area Rapid Transit District Study Guide for the Electronics Technician Pre-Employment Examination INTRODUCTION The Bay Area Rapid Transit (BART) District makes extensive use of electronics technology
Yrd. Doç. Dr. Aytaç Gören
H2 - AC to DC Yrd. Doç. Dr. Aytaç Gören ELK 2018 - Contents W01 Basic Concepts in Electronics W02 AC to DC Conversion W03 Analysis of DC Circuits W04 Transistors and Applications (H-Bridge) W05 Op Amps
VERIFICATION OF THEORETICAL PHONG MODEL IN REFLECTOR LESS SURVEYS
TECHNICAL SCIENCES Abbrev.: Techn. Sc., No 14(2), Y 2011 VERIFICATION OF THEORETICAL PHONG MODEL IN REFLECTOR LESS SURVEYS Kamil Kowalczyk 1, Jacek Rapiński 2 1 Chair of Land Surveying and Geomatics 2
Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies
Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the
Electricity Meter in the age of Photovoltaic
Electricity Meter in the age of Photovoltaic Avi Lugassi Introduction In this article we will learn how the electronic Energy Meter can deal with the massive penetration of renewable Photovoltaic energy
Power Quality & Custom Power
Day-3 Power Quality & Custom Power Arindam Ghosh Dept. of Electrical Engineering Indian Institute of Technology Kanpur,, India E-mail: aghosh@iitk iitk.ac.in Power Quality (PQ) The term electric power
APPLICATION NOTES: Dimming InGaN LED
APPLICATION NOTES: Dimming InGaN LED Introduction: Indium gallium nitride (InGaN, In x Ga 1-x N) is a semiconductor material made of a mixture of gallium nitride (GaN) and indium nitride (InN). Indium
Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems
Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems by Reza Tajali, P.E. Square D Company, Power Systems Engineering Group 295 Tech Park Drive LaVergne, Tennessee 37086
Diode Circuits. Operating in the Reverse Breakdown region. (Zener Diode)
Diode Circuits Operating in the Reverse Breakdown region. (Zener Diode) In may applications, operation in the reverse breakdown region is highly desirable. The reverse breakdown voltage is relatively insensitive
Power Quality Standards for Electric Service
Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as
How To Limit Voltage Unbalance
Engineering Recommendation No.10 of the Electricity Distribution Code Limits for Voltage Unbalance in the Electricity Supply System Version 1.0 30th November 2005 Prepared by: Abu Dhabi Distribution Company,
HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM
Technical Note No.3 March 2000 HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses harmonic distortion, its causes and adverse effects, what levels are unacceptable and how
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Troubleshooting accelerometer installations
Troubleshooting accelerometer installations Accelerometer based monitoring systems can be tested to verify proper installation and operation. Testing ensures data integrity and can identify most problems.
ELECTRONIC POWER SYSTEMS
ELECTRONIC POWER SYSTEMS TRADEOFFS BETWEEN SINGLE-PHASE & THREE-PHASE POWER WHITE PAPER: TW0057 1 Executive Summary Modern Electronic Systems are quite often powered from a three-phase power source. While
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
Project 2B Building a Solar Cell (2): Solar Cell Performance
April. 15, 2010 Due April. 29, 2010 Project 2B Building a Solar Cell (2): Solar Cell Performance Objective: In this project we are going to experimentally measure the I-V characteristics, energy conversion
GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS
TR TSY 000757 GENERIC REQUIREMENTS FOR UNINTERRUPTIBLE POWER SYSTEMS (UPS) TABLE OF CONTENTS 1. Introduction.... 1.1 Purpose and Scope 1.2 Organization.. 1.3 Reason for Reissue From Technical Advisory
Typical Data Requirements Data Required for Power System Evaluation
Summary 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com [email protected] Harmonic Filter & Power Capacitor Bank Application Studies This document describes NEPSI
Laboratory and field measurements of the power factor and the harmonic emission from energy-efficient lamps
Laboratory and field measurements of the power factor and the harmonic emission from energy-efficient lamps Sarah K. Rönnberg (1), Math H.J. Bollen (1,2), Mats Wahlberg (1,3) (1) Luleå University of Technology,
LM1036 Dual DC Operated Tone/Volume/Balance Circuit
LM1036 Dual DC Operated Tone/Volume/Balance Circuit General Description The LM1036 is a DC controlled tone (bass/treble), volume and balance circuit for stereo applications in car radio, TV and audio systems.
DIODE CIRCUITS LABORATORY. Fig. 8.1a Fig 8.1b
DIODE CIRCUITS LABORATORY A solid state diode consists of a junction of either dissimilar semiconductors (pn junction diode) or a metal and a semiconductor (Schottky barrier diode). Regardless of the type,
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Electrical Shore Connections / Cold Ironing
STANDARD FOR CERTIFICATION No. 2.25 Electrical Shore Connections / Cold Ironing JULY 2014 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version
Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors
Applied and Computational Mechanics 3 (2009) 331 338 Mathematical Modeling and Dynamic Simulation of a Class of Drive Systems with Permanent Magnet Synchronous Motors M. Mikhov a, a Faculty of Automatics,
21 st Century Facilities
Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer
Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques
Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Howard W. Penrose, Ph.D On behalf of ALL-TEST Pro, LLC Old Saybrook, CT Introduction Field and shop testing of
Survey of Harmonics Measurements in Electrical Distribution Systems
Survey of Harmonics Measurements in Electrical Distribution Systems Leon M. Tolbert, Member, EEE Oak Ridge ational Laboratory* P.O. Box 8, Bldg Oak Ridge, T 3783-6334 Alexandria, VA 35-386 Phone: (43)
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
Lecture - 4 Diode Rectifier Circuits
Basic Electronics (Module 1 Semiconductor Diodes) Dr. Chitralekha Mahanta Department of Electronics and Communication Engineering Indian Institute of Technology, Guwahati Lecture - 4 Diode Rectifier Circuits
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
ENERGY EFFICIENT LIGHTING
ENERGY EFFICIENT LIGHTING Prof. Suryanarayana y Doolla IIT Bombay Dept. of Energy Science & Engineering Content 2 Basics of Illumination Types of light source, lighting Comparison of commercial lamps Energy
ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING
ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EEM 102 INTRODUCTION TO ELECTRICAL ENGINEERING EXPERIMENT 9: DIODES AND DC POWER SUPPLY OBJECTIVE: To observe how a diode functions
Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.
Power Electronics Prof. K. Gopakumar Centre for Electronics Design and Technology Indian Institute of Science, Bangalore Lecture - 1 Electric Drive Today, we will start with the topic on industrial drive
POWER EFFICIENCY MANAGEMENT OF PHOTOVOLTAIC ENERGY SOURCE BASED ON MPPT ALGORITHM
TECHNICAL TRANSACTIONS MECHANICS CZASOPISMO TECHNICZNE MECHANIKA 1-M/2013 ZDZISŁAW JUDA*,TOMASZ NABAGŁO*, PAWEŁ OCŁOŃ**, BOHDAN WĘGLOWSKI**, MARIUSZ KRAWCZYK*** POWER EFFICIENCY MANAGEMENT OF PHOTOVOLTAIC
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
NATIONAL CERTIFICATE (VOCATIONAL)
NATIONAL CERTIFICATE (VOCATIONAL) SUBJECT GUIDELINES ELECTRICAL PRINCIPLES AND PRACTICE NQF Level 4 September 2007 ELECTRICAL PRINCIPLES AND PRACTICE LEVEL 4 CONTENTS INTRODUCTION 1 DURATION AND TUITION
Electronics I - Laboratory 1 Diode I/V Characteristics
Electronics I - Laboratory 1 Diode I/V Characteristics I. Objectives 1. Develop I/V characteristics of a silicon diode. 2. Develop I/V characteristics of a germanium diode. 3. Develop I/V characteristics
TDA2040. 20W Hi-Fi AUDIO POWER AMPLIFIER
20W Hi-Fi AUDIO POWER AMPLIFIER DESCRIPTION The TDA2040 is a monolithic integrated circuit in Pentawatt package, intended for use as an audio class AB amplifier. Typically it provides 22W output power
PLA 44. Power quality analyzer. User and service manual. BMR trading
PLA 44 Power quality analyzer User and service manual version 1.2 BMR Lipovka 17 516 01 Rychnov n. Kn. 1 Tel: +420 774 415 703 Fax: +420 494 533 602 Content 1. Front panel...3 5.6.1. List of events...8
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
Power Quality for Information Technology System
Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS
Electricity for the Entertainment Electrician Ef Technician
Electricity for the Entertainment Electrician Ef Technician Richard Cadena ЩШ ' AMSTERDAM BOSTON HEIDELBERG LONDON NEW YORK JPPwlffl OXFORD PARIS SAN DIEGO SAN FRANCISCO л»еж SINGAPORE SYDNEY TOKYO ELSEVIER
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
LM1084 5A Low Dropout Positive Regulators
5A Low Dropout Positive Regulators General Description The LM1084 is a series of low dropout voltage positive regulators with a maximum dropout of 1.5 at 5A of load current. It has the same pin-out as
DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT
DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT by Philip J. A. Ling, P.Eng. Cyril J. Eldridge, B. Sc. POWERSMITHS INTERNATIONAL
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules Abstract J.L. Crozier, E.E. van Dyk, F.J. Vorster Nelson Mandela Metropolitan University Electroluminescence (EL) is a useful
Mureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
Electronics Technology
Teacher Assessment Blueprint Electronics Technology Test Code: 5907 / Version: 01 Copyright 2011 NOCTI. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information
PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps
EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim
Electronics Technology
Job Ready Assessment Blueprint Electronics Technology Test Code: 4035 / Version: 01 Copyright 2010. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information
How To Calculate The Neutral Conductor Current
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, VOL. 39, NO. 3, MAY/JUNE 2003 587 Analysis of the Neutral Conductor Current in a Three-Phase Supplied Network With Nonlinear Single-Phase Loads Jan J. M. Desmet,
GenTech Practice Questions
GenTech Practice Questions Basic Electronics Test: This test will assess your knowledge of and ability to apply the principles of Basic Electronics. This test is comprised of 90 questions in the following
Development of an Electrical Power Quality Monitor Based on a PC
Renato Alves, D. Gonçalves, J. G. Pinto, José Batista, João L. Afonso, Development of an Electrical Power Quality Monitor Based on a PC, IECON 2009 - The 35th Annual Conference of the IEEE Industrial Electronics
Fundamentals of Signature Analysis
Fundamentals of Signature Analysis An In-depth Overview of Power-off Testing Using Analog Signature Analysis www.huntron.com 1 www.huntron.com 2 Table of Contents SECTION 1. INTRODUCTION... 7 PURPOSE...
Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
INDICATOR LAMPS & LED REPLACEMENT LAMPS
INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC
Analysis of AC-DC Converter Based on Power Factor and THD
Website: www.ijetae.com (SSN 50-459, SO 900:008 Certified Journal, Volume 3, ssue, February 03) Analysis of AC-DC Converter Based on Power Factor and THD Shiney.S.Varghese, Sincy George Department of Electrical
Integrated impedance scanner in selected biomeasurement applications control circuit
Łukasz Przeniosło Marcin Walków Sonia Krzeszewska Sandra Pisarek Biomedical Engineering Student Research Group "AKSON" Andrzej Biedka Marek Jaskuła Daniel Matias Krzysztof Penkala Department of Systems,
MATERIALS. Multisim screen shots sent to TA.
Page 1/8 Revision 0 9-Jun-10 OBJECTIVES Learn new Multisim components and instruments. Conduct a Multisim transient analysis. Gain proficiency in the function generator and oscilloscope. MATERIALS Multisim
Special-Purpose Diodes
7 Special-Purpose Diodes 7.1 Zener Diode 7.2 Light-Emitting Diode (LED) 7.3 LED Voltage and Current 7.4 Advantages of LED 7.5 Multicolour LEDs 7.6 Applications of LEDs 7.7 Photo-diode 7.8 Photo-diode operation
Equivalent Circuit. Operating Characteristics at Ta = 25 C, V CC = ±34V, R L = 8Ω, VG = 40dB, Rg = 600Ω, R L : non-inductive load STK4181V
Ordering number: 2137B Thick Film Hybrid IC STK4181V AF Power Amplifier (Split Power Supply) (45W + 45W min, THD = 0.08%) Features Pin-compatible with the STK4102II series. The STK4101V series use the
Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
Kit 27. 1W TDA7052 POWER AMPLIFIER
Kit 27. 1W TDA7052 POWER AMPLIFIER This is a 1 watt mono amplifier Kit module using the TDA7052 from Philips. (Note, no suffix.) It is designed to be used as a building block in other projects where a
Characteristic curves of a solar cell
Related Topics Semi-conductor, p-n junction, energy-band diagram, Fermi characteristic energy level, diffusion potential, internal resistance, efficiency, photo-conductive effect, acceptors, donors, valence
Power Electronics Testings
Power Electronics Testings PV Inverter Test Solution www.chromaate.com Turnkey Test & Automation Solution Provider w w w.chromaate.com A PV system is an energy system which directly converts energy from
* Requires external power line filter and hold up capacitors; see typical applica on circuit and app notes for details
The 8500 module contains all of the necessary circuitry for complete power line compliance with aeronau cs specifica on RTCA/DO 60G and Boeing's D6 36440(C)*. It is a pin for pin and form fit compa ble
Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor
International Journal of Innovation and Scientific Research ISSN 2351-8014 Vol. 11 No. 2 Nov. 2014, pp. 445-449 2014 Innovative Space of Scientific Research Journals http://www.ijisr.issr-journals.org/