A Modified UCT Method for Enhanced Biological Phosphorus Removal
|
|
|
- Marvin Wilson
- 10 years ago
- Views:
Transcription
1 A Modified UCT Method for Enhanced Biological Phosphorus Removal Proceedings of European Congress of Chemical Engineering (ECCE-6) Copenhagen, 16-2 September 27 A Modified UCT Method for Enhanced Biological Phosphorus Removal A. Eleni Vaiopoulou, a B. Alexander Aivasidis, a a Department of Environmental Engineering, Democritus University of Thrace,67 1 Xanthi, Greece Abstract Biological Nutrient Removal Activated Sludge (BNRAS) systems remove carbon, nitrogen and phosphorus by biological means with low costs and less waste sludge production. One of the most commonly applied BNRAS methods for urban wastewater treatment relies on the University of Cape Town (UCT) concept. The pilot-scale prototype BNRAS system presented here combines both, the idea of UCT concept and the step denitrification cascade for integrated removal of carbon, nitrogen and phosphorus. The experimental set-up of 44 L operational volume consists of an anaerobic selector and stepwise feeding in subsequent anoxic and oxic tanks. Raw wastewater with influent flow rates ranging between L/d was fed to the unit at Hydraulic Residence Times (HRT) of 5 18 h and specific BOD 5 loading rates of.8.82 kg BOD 5 / (kg MLVSS d). Influent flow rate (Q F ) is distributed at percentages of 6/25/15, 4/3/3 and 25/4/35 % to the anaerobic selector (AN), 2 nd (DN2) and 3 rd (DN3) anoxic tank respectively. The overall Sludge Retention Time (SRT, θc) was kept constant at 1 d and temperature at 2 C. The results of two year operation show high removal efficiencies of organic matter of 89% as total COD removal and 95% removal for BOD 5, complete nitrification (95% removal of ammonium-nitrogen), 9% removal of Total Kjeldahl Nitrogen (TKN) and total nitrogen removal through denitrification of 73%. Phosphorus removal attains a mean value of 67%. All removal efficiencies receive constantly the highest values at the feeding ratio of 6/25/15. Moreover, plant configuration provides operational conditions that suppress filamentous bacteria and favour growth of floc-formers, and thus leads to high sludge settleability characteristics (Sludge Volume Index 1 ml/g). The highest removal efficiency and the optimum operation are recorded at HRT of about 9 hrs and influent flow rate of 96 L/d, which is distributed by 6% to the anaerobic selector, by 25% to second anoxic tank and by 15% to the last anoxic tank. Removal efficiency of organic substrate is 94% and 98% for COD and BOD 5 respectively, 99% for ammonium nitrogen, 94% for TKN, 83% for total nitrogen and 93% for orthophosphates. Keywords: UCT, wastewater, nutrients, phosphorus, step feeding, BNRAS
2 Vaiopoulou et al. 1. Introduction Nitrogen and phosphorus are limiting nutrients in most freshwater systems and cause eutrophication. Recently, interest has been developed in the use of biological, rather than chemical processes for phosphorus and nitrogen removal from wastewater. Increasing demands for lower effluent concentrations of nutrients in combination with minimized cost requirements, has encouraged researchers and plant operators to focus on nutrients removal optimization. Biological nitrogen removal is a two step process including ammonia oxidation by nitrification, followed by reduction of nitrogen oxides to nitrogen gaseous compounds by denitrification (Wagner et al., 22). As a result, a sequence of oxic and anoxic conditions is required for nitrogen removal. Biological phosphorus removal from wastewaters exploits the potential of some microorganisms, known as Phosphate Accumulating Organisms (PAOs), to accumulate phosphate (as intracellular polyphosphate) in excess of their normal metabolic requirements under aerobic conditions (Seviour et al., 23). In the anaerobic phase, sufficient readily biodegradable carbon sources, such as volatile fatty acids (VFAs), must be available to induce PAOs to take up the acids, store them as poly-β-hydroxyalkanoates (PHA) and release orthophosphates into the solution (Seviour et al., 23). This means that under anaerobic conditions PAOs gain the selective advantage over other bacteria. The bottleneck of the process is that PAOs accumulate aerobically more phosphorus than the phosphorus released under anaerobic conditions. Sludge wasting after aeration leads to phosphorus removal. Key wastewater characteristics, such as VFA content, ph, cations etc, and operational parameters, such as temperature, oxygen concentration, sludge quality etc, affect the successful removing of phosphorus (Mullkerins et al., 24). Biological Nutrient Removal Activated Sludge (BNRAS) systems remove carbon, nitrogen and phosphorus by biological means with low costs and less waste sludge production. One of the most commonly applied BNRAS methods for urban wastewater treatment relies on the University of Cape Town (UCT) concept. The UCT process was designed to minimize the effect of nitrate to the anaerobic contact zone, which is crucial for maintaining truly anaerobic conditions and thus, allowing biological phosphorus release. In fact, the higher the phosphorus concentration released in the anaerobic tank, the higher is the phosphorus concentration taken up under aerobic conditions. An improvement of the UCT method could be obtained through recycling of sludge from the clarifier to an anoxic stage before entering the anaerobic tank. This would result in nitrate reduction by denitrification and thus, neither oxygen nor nitrate would enter the anaerobic reactor and damage the anaerobic conditions. From a biological aspect, the anaerobic selector not only contributes to phosphorus removal, but also forms heavy large flocs that enhance settleability (Metcalf & Eddy, 23). Experiments and full scale applications have shown that this pre-denitrification nitrification process, which includes an anaerobic selector and internal recycle mixed liquor, is efficient for removal of organic substrate, nitrogen and phosphorus from wastewater (Schlegel, 1992; Ekama and Wentzel, 1999; Metcalf & Eddy, 23). The modified UCT method upgraded the 2
3 A Modified UCT Method for Enhanced Biological Phosphorus Removal process; however, an internal recycling of nitrified liquor to an anoxic tank is still needed (Metcalf & Eddy, 23). Modifications in such BNRAS systems have proved that step feeding is an attractive process to eliminate the need for internal recycling, sludge recirculation and to optimize organic carbon utilization for denitrification, resulting thus in energy savings (Metcalf & Eddy, 23; Görgün et al., 1996; Pai et al., 24; Schlegel, 1992; Vaiopoulou et al., 27). On the other hand, multiple stage cascades optimize removal efficiency with minimum reactor volume. A cascade of three stages is expected to yield to optimum effluent quality, which is shown by model simulation results (Görgün et al., 1996). Experiments on nutrients removal in a two denitrification stage UCT system with step feeding and influent flow distribution by 5% to the anaerobic tank and the rest to the second anoxic tank showed high removal efficiencies (Schlegel, 1992). A similar attempt was undertaken by Pai et al. resulting to an economically efficient removal of organic substrate and nutrients with highly clarified effluent (24). However, the effect of the step feeding process was minimized, whereas the plant was fed with a synthetic wastewater, which can not simulate successfully real wastewater. The regime and feed pattern in a wastewater treatment plant affects the microbial population synthesis and characteristics and thus, the removal efficiency of the unit (Wagner et al., 22; Zeng et al., 24). Indeed, personal previous experience using synthetic feed showed that artificial wastewater does not give a realistic view of the system performance (Vaiopoulou et al., 27). On this basis, the UCT approach could be enhanced by combining multiple stages of anoxic and oxic zones with the step feeding process. Herein a modified UCT method is proposed, which consists of an initial anaerobic selector followed by a cascade of three identical pairs of tanks. Each pair comprises of an anoxic and aerobic tank for denitrification and nitrification respectively. The initial anaerobic tank helps select phosphate accumulating organisms, according to the EBPR technique, as well as flocformers over filamentous bacteria. The cascade is supposed to lead to high removal efficiency, optimum effluent quality and favorable residence time distribution with minimal reactor volume. The three-stage cascade is expected to yield a potential (theoretical) removal efficiency of total nitrogen around 83% (data not shown), when sludge recycle ratio is equal to the influent flow rate. Multiple stage cascades also offer the operational assurance of removing anything left untreated in a following stage. Step feeding strategy is adopted providing raw wastewater to the anaerobic selector, to the 2nd and 3rd anoxic tank transforming these tanks into selectors of floc-formers over filaments, whereas a cheap organic carbon source is available for denitrification. The feeding ratios of the influent flow rate to the anaerobic selector and anoxic tanks were calculated so that the carbon to nitrogen ratio is theoretically sufficient for denitrification. In particular, these influent percentages to the anaerobic selector, to the 2nd and 3rd anoxic tank are proposed as 6/25/15, 4/3/3 and 25/4/35 % of total influent flow rate respectively. Internal nitrified liquor recycle is not necessary, whereas sludge recycle is introduced to the anaerobic selector via the 1st anoxic tank. This results in 1) nitrate elimination before entering the anaerobic selector, 2) sludge recycle flow minimization and 3) supply of the anaerobic selector with biomass. Primary sedimentation is excluded and thus, organics and nutrients are 3
4 Vaiopoulou et al. maintained, which are essential to following procedures of phosphorus removal and denitrification. Since such modifications would most probably result in a satisfactory performance with low costs, and since BNRAS systems are complex with many dependent interactions, experimental procedures are essential for evaluating their performance and design. Therefore, the objective of this work is to present a novel pilot-scale activated sludge system for biological removal of organic substrate, nitrogen and phosphorus, combining the idea of the UCT process with the step feeding approach, and also to confirm the theoretically expected design advantages. Performance, operation and removal efficiency of two alternative feeding schemes are also investigated aiming at process optimization. 2. Materials and Methods 2.1. Plant description The experimental unit described here is an activated sludge system for enhanced biological phosphorus removal (Fig.1), which includes an anaerobic selector and stepwise feeding in subsequent anoxic and oxic vessels for simultaneous removal of BOD5/COD and suspended solids, as well as nitrogen and phosphorus. The pilot plant has total operational volume of 44 L and consists of an anaerobic selector (ANAER) of 3.5 L followed by a cascade of three identical pairs of anoxic/aerobic bioreactors. Denitrification takes place in the three anoxic bioreactors (DNi, i=1 to 3), which have an operational volume of 3.4 L each, whereas nitrification and carbon oxidation is accomplished in the three aerobic bioreactors (AEi), which have an operational volume of 7.3 L each. Switching between anaerobic and aerobic conditions favors the growth of PAOs, and thus, biological phosphorus removal (Wagner et al., 22; Seviour et al., 23). Finally, a secondary sedimentation tank (ST) of 8.3 L is used for sludge separation and recycling into the anaerobic selector via the first anoxic tank. Sludge wastage and recycle are controlled by a timer that switches on/off a magnetic three-way valve. Wastewater transfer from one tank to the following one is performed in part by free overflow and in part by use of level controllers and peristaltic pumps. In particular, the reactors are connected with a piping system so that the wastewater or mixed liquor suspended solids (MLSS) are introduced at the bottom and withdrawn from the top of each reactor. The piping system is so designed that unintentional oxygenation of the water or MLSS is kept at a minimum. Aeration is performed by the diffused aeration method, i.e. air is introduced at the bottom of the aerobic bioreactors through special porous material. Air flow meters are used for manual control of air flow rates in each aerobic tank. All tanks are gently stirred. 4
5 A Modified UCT Method for Enhanced Biological Phosphorus Removal Figure 1. View of the Biological Nutrient Removal Activated Sludge (BNRAS) system. The pilot-scale plant has been in operation for about two years. The plant was fed with raw municipal wastewater from the combined sewer system of Xanthi city in Greece. Particularly, charges of one cubic meter were delivered once or twice per week depending on influent volume needs. Influent average concentrations of BOD5 and COD were 32 mg/l and 51 mg/l respectively. Influent orthophosphate phosphorus and total phosphorus concentration spanned a range between 2-9 mg PO P/L and 2-15 mg TP/L. The percentage of orthophosphates content in total phosphorus was in average 63%. Total nitrogen influent concentration was typically around 55 mg/l. Wastewater characterization is presented in Table 1. No addition of chemicals took place to provide convenient values of wastewater pollutants. With the exception of some low phosphorus concentrations, organic substrate and nitrogen extent can be regarded as normal for a Greek municipal or domestic wastewater. 5
6 Vaiopoulou et al. Table 1. Wastewater characterization of municipal origin. Concentration (mg/l) Pollution parameter Min Mean Max Total Suspended Solids (TSS) Volatile Suspended Solids (VSS) Non-Volatile SS (NVSS) COD p BOD Total Nitrogen (ΤΝ) Total Kjedahl Nitrogen (ΤΚΝ p ) Ammonium nitrogen (NH N) Organic Nitrogen Nitrate/ Nitrite (ΝΟ - x -Ν) Total Phosphorus (TP) 1, Orthophosphates (PO P),3 5 9,2 Influent wastewater rate (Q F ) is distributed to the anaerobic selector with a flow rate of Q ANAER, and to the second and third anoxic zone with flow rates of Q DN2 and Q DN3 respectively, as shown in Fig. 2 (influent flow distribution before the anaerobic selector). Incoming percentages are calculated according to the ratio of the tank flow rate to the total influent flow rate (e.g. Q DN2 /Q F ). During the experiments reported here, influent flow distribution to the anaerobic selector, and the second and third anoxic tank (Q ANAER /Q DN2 /Q DN3 ) was set to 6/25/15, 4/3/3 and 25/4/35 %. Influent flow rates (Q F ) into the activated sludge system were increased from 48 to 168 L/d in order to obtain a hydraulic residence time (HRT, θ) from 18 to 5 hours respectively. HRT is calculated excluding the clarifier at an operational working volume of 35.6 L. Sludge recycling rate (Q R ) was set equal to influent flow rate (Q R = Q F ) for each run, whereas the overall sludge retention time (SRT, θc) was kept constant at 1 days by controlling sludge wastage flow rate. 6
7 A Modified UCT Method for Enhanced Biological Phosphorus Removal Figure 2. Experimental set-up of the BNRAS system Flow pattern alternatives Two alternative feeding patterns of the described plant were investigated. The two influent flow pattern alternatives refer to the influent flow distribution before or after the anaerobic selector. This means that the influent wastewater is either distributed to the anaerobic tank, to the second and third anoxic tank (influent flow distribution before the anaerobic selector), or, in the alternative flow pattern design, the influent wastewater is first introduced to the anaerobic tank and afterwards distributed to the three anoxic tanks (influent flow distribution after the anaerobic selector) (Fig.3). Both flow schemes do not permit introduction of nitrate to the anaerobic selector, thus protecting the sensitive process of phosphorus release, whereas step feeding to anoxic tanks provides essential carbon compounds for the denitrification process. (A) Municipal wastewater Step feeding Q F Q DN2 Q DN3 Q ANAER Q R DN1 AE1 DN2 AE2 DN3 AE3 Anoxic Aerobic Anoxic Aerobic Anoxic Aerobic Clarifier Effluent Anaerobic Sludge recirculation Q R Waste sludge 7
8 Vaiopoulou et al. (B) Municipal wastewater Step feeding Q F Q DN2 Q DN3 Q ANAER Q R DN1 AE1 DN2 AE2 DN3 AE3 Anoxic Aerobic Anoxic Aerobic Anoxic Aerobic Clarifier Effluent Anaerobic Sludge recirculation Q R Waste sludge Figure 3. Schematic layout of the feed distribution pattern (A) before and (B) after the anaerobic selector in the pilot scale BNRAS plant. The influent flow distribution pattern before the anaerobic selector was thoroughly investigated by introducing a wide range of influent flow rates (from 48 to 168 L/d) at different feed distribution percentages (6/25/15, 4/3/3 and 25/4/35 %), whereas the influent flow distribution pattern after the anaerobic selector was operated under optimum feed conditions with the aim to optimize the unit efficiency and performance. Therefore, HRTs in the influent flow distribution pattern before the anaerobic selector range between 5 and 18 hrs, whereas HRTs in the influent flow distribution pattern after the anaerobic selector range between 6 and 9 hrs. In Table 2 operational conditions, loadings and loading rates for organic, nitrogenous and phosphorus substrates are presented for each run. The main disadvantage of feeding with real wastewater is the fluctuations of substrate concentrations, which are evident in Table 2. However, loading rates of organics and nitrogen tend to increase when increasing the influent flow rate, as expected. On the other hand, intense fluctuations in influent orthophosphates concentration result to phosphorus loading rate fluctuations, which are hardly correlated to the influent flow rate. 8
9 A Modified UCT Method for Enhanced Biological Phosphorus Removal Table 2. Operational parameters of the BNRAS plant. Stst (AN/DN2/DN3) Q F [L/hr] Loading (g/d) Sludge Loading NH + - Rate (L no. [%Q F ] COD BOD 4 - PO RX ) 4 5 N 3 [kg - P BOD5 /(kg MLVSS d)] Influent flow distribution before the anaerobic selector HRT τ [d] 1 2 (6/25/15) (4/3/3) (25/4/35) (6/25/15) (4/3/3) (25/4/35) (6/25/15) (4/3/3) (25/4/35) (6/25/15) (4/3/3) (25/4/35) (6/25/15) (6/25/15) Stst no. Q F [L/hr] (DN1/DN2/DN3) [%Q F ] Loading (g/d) Influent flow distribution after the anaerobic selector Sludge Loading Rate (L RX ) [kg BOD5 /(kg MLVSS d)] HRT τ [d] 1 4 (6/25/15) (6/25/15) (6/25/15) Water quality monitoring Under steady-state conditions, samples were collected from the influent of the unit and the effluents of each tank, as well as from the separated sludge in the clarifier. The samples were analyzed following standard procedures for the determination of BOD 5, particulate and soluble COD, ammonia, particulate and soluble TKN (Total Kjedahl Nitrogen), nitrite, nitrate, total phosphorus, orthophosphate, VSS (Volatile 9
10 Vaiopoulou et al. Suspended Solids) and SVI (Sludge Volume Index) (Standard Methods for the Examination of Water and Wastewater, 1998). A High Pressure Liquid Chromatography with a 55 conductivity detector and a 53 column heater of Alltech, USA was used for anion determination in isocratic mode after filtration of samples through.2 µm filters. A Marathon IV HPLC pump with flow rate of 2 ml/min was driving the filtered samples to pre-columns before entering the Hamilton PRP-X1 column. The system was running on EZ Chrom software. Wastewater temperature, ph and dissolved oxygen (DO) were monitored on a daily basis. Typical values for ph ranged between 7.4 and 7.6, whereas temperature was kept constant at 2 ºC. The DO in the aerated reactors was maintained above 2 mg/l during the experimental period. Sludge samples were also frequently taken and were observed within one hour under bright field and phase contrast microscopy. A start-up period of about one month is required for biomass acclimation and stable unit performance. Once the operational conditions (i.e., influent flow rate and step feeding distribution) were set, the pilot plant was run until it reached steady state conditions. According to a rule of thumb, steady state conditions are reached after five times the HRT of the plant, since the unit consists of a Continuous Flow Stirred Tank Reactors (CFSTR) cascade. However, in order to assure steady state conditions in practice, samples were taken periodically to check the stability of the unit efficiency. When steady state conditions were confirmed, sampling, analyzing and finally set of operational conditions for the next run were taking place. Experiments were at least three times run to ensure results reproducibility. 3. Results 3.1. Unit performance The results of two year operation running on influent flow distribution before the anaerobic selector show constantly high removal efficiencies of organic matter of 89% as total COD and 95% removal for BOD 5 averagely. Figure 4 depicts the influent and effluent concentrations of BOD 5 and COD for each steady state experiment including removal efficiency. Results for each pollution parameter, which are presented in charts, are divided by vertical lines in three sections corresponding to the three feeding ratios to the anaerobic selector, the second and third anoxic tank (6/25/15, 4/3/3 and 25/4/35). Total COD removal ranged between 8-98% and BOD 5 removal between 87-98%, receiving constantly the highest values at the feeding ratio of 6/25/15. A slight drop in BOD 5 and COD removal is observed at low HRTs (high influent flow rate), although the plant was fed with the ratio of 6/25/15, which is attributed both to the high hydraulic loading and loading rate of organic substrate. COD removal fluctuates around 88% in feeding schemes of 4/3/3 and 25/4/35, whereas it remains constantly above 9% during feeding at the ratio of 6/25/15. The influent total COD concentrations with a mean value of 54 mg/l spanned between mg/l, whereas effluent concentrations with a mean value of 55 mg/l fluctuated between mg/l. Accordingly, mean influent concentration of BOD5 was 33 mg/l with a width of mg/l, whereas effluent concentrations ranged between 5-35 mg/l with an average value of 18 mg/l. 1
11 A Modified UCT Method for Enhanced Biological Phosphorus Removal BOD5 (mg/l) CODtot (mg/l) AN/DN2/DN3 (%Q F ) 6/25/15 4/3/3 25/4/ Q F (L/h) CODtot,in CODtot,out Removal Figure 4. Removal efficiency of organic substrate under influent flow distribution before the anaerobic selector. Complete nitrification is accomplished in all steady state experiments with the exception of low HRTs runs (Fig. 5). Mean removal of ammonium-nitrogen and TKN is 95% and 9% respectively. However, ammonium removal, and thus nitrification, is even higher since more ammonium nitrogen is produced from organic nitrogen in the plant after wastewater entrance. Removal efficiency is constantly higher at the feeding ratio of 6/25/15 with the exception of the steady state experiments at low HRTs (6 and 7 L/hr). The lowest TKN removal of 68% and the highest ammoniumnitrogen effluent concentration (7.8 mg/l) were recorded at HRT of about 5 hrs (QF = 7 L/hr) in the feed ratio of 6/25/15. Mean influent and effluent NH 4 + -N concentrations attain values of 4 and 2 mg/l respectively, whereas mean influent and effluent TKN concentrations receive values of 56 and 6 mg/l respectively. On the other hand, denitrification efficiency fluctuated fairly at the feeding ratios of 4/3/3 and 25/4/35, whereas at the feeding ratio of 6/25/15 was constantly high attaining the highest extent at HRT of about 6 hrs (Q F = 6 L/hr) (Fig. 5). Total Q F (L/h) BODin BODout Removal AN/DN2/DN3 (%Q F ) 1 6/25/15 4/3/3 25/4/ % Removal % Removal 11
12 12 Vaiopoulou et al. nitrogen influent concentrations ranged between 4-6 mg/l with a mean value of 52 mg/l, whereas mean effluent concentration was 14 mg/l fluctuating between 8 and 19 mg/l. The low removal efficiency and the high effluent concentrations are attributed to the high nitrate effluent concentrations, which in some cases exceeded 1 mg/l in the feeding ratios of 4/3/3 and 25/4/35. This result is most probably attributed to the unit configuration, which ends to an aerobic tank, where nitrification is processed and nitrate is produced. However, aerobic conditions as the final step are essential for phosphate accumulation and maintenance of phosphorus effluent concentrations at low levels. Another explanation could be the accumulation of nitrate from previous aerobic stages on its way to the effluent. TKN (mg/l) ΤN (mg/l) AN/DN2/DN3 (%Q F ) 6/25/15 4/3/3 25/4/ Q F (L/h) TKNin TKNout AN/DN2/DN3 (%Q F ) Removal 6/25/15 4/3/3 25/4/ Q F (L/h) TNin TNout Removal Figure 5. Removal efficiency of total Kjedahl nitrogen and total nitrogen under influent flow distribution before the anaerobic selector. When compared to the results of a similar two-stage plant (Schlegel, 1992), the removal efficiencies of organic and nitrogenous pollutants are enhanced in the present BNR unit. This finding was expected since the cascade increase, besides being a safer mode of operation, may also result to higher plant removal efficiency. However, a % Removal % Removal
13 A Modified UCT Method for Enhanced Biological Phosphorus Removal further increase of the tank number could provide an even higher efficiency, but also a much higher construction and operation cost. The phosphate removal efficiency ranges intensively between 27-96% with a mean value of 67% (Fig. 6), which is attributed to the influent concentration fluctuation. A revision paper underlines the significance of stable operating conditions and influent concentrations for a successful phosphorus removal (Mullkerins et al., 24). Influent phosphate concentrations spanned between 2-9 mg/l with an average value of 5 mg/l, whereas mean effluent phosphate concentration was less than 2 mg/l with a width of mg/l. The lowest removal efficiency was recorded at the highest HRT (Q F = 2 L/hr). Constantly high removal efficiencies occurred at HRTs of 5 to 9 hrs at the feeding ratio of 6/25/15, during which the phosphate loading rate exceeded the 1 g/ (m 3 d). Total phosphorus removal efficiency followed the same profile with a mean value of 53% ranging between 3% and 79%. Mean influent total phosphorus concentration was about 8 with a width of 2-15 m/l, whereas mean effluent concentration was 3.4 mg/l fluctuating between mg/l. ΡΟ4 3- -Ρ (mg/l) AN/DN2/DN3 (%Q F ) 6/25/15 4/3/3 25/4/ Q F (L/h) ΡΟ4Ρin ΡΟ4Ρout Removal % Removal Figure 6. Removal efficiency of phosphate under influent flow distribution before the anaerobic selector. Throughout the experimental period, long, robust and compact flocs comprised of a large species diversity could be observed under bright field and phase contrast microscopy. MLVSS concentration decreased averagely from 3.3 g/l in DN1 to 2.5 g/l in AE3 due to the sludge recycle entering DN1 tank, due to the dilution effect and to the higher HRTs in the initial tanks, which are attributed to the step feeding process. The same profile stands for Sludge Volume Index (SVI), which decreased averagely from 16 ml/g in AE1 and 13 ml/g in AE2 to 1 ml/g in AE3 and thus, in the clarifier. These SVI values are characterized as ideal (Jenkins et al., 1993) and show that the unit configuration actually results to enhanced sludge settleability. Accordingly, mean effluent MLVSS concentration was less than 25 mg/l which ensures a well-clarified effluent. However, SVI attains values higher than 15 ml/g at HRT of about 12 hrs at the feeding ratio of 25/4/35. Removal efficiency and sludge 13
14 Vaiopoulou et al. characteristics results are in agreement with previous experimental findings in similar units (Kayser et al., 1992; Pai et al., 24; Schlegel, 1992). 2 AN/DN2/DN3 (%Q F ) 6/25/15 4/3/3 25/4/35 15 SVIΑΕ3 (ml/g) Q F (L/h) Figure 7. Sludge volume index (SVI) in the last aerated tank (AE3) under influent flow distribution before the anaerobic selector. It is quite clear that the feeding ratio of 6/25/15 to the anaerobic selector, to the second and third anoxic tank results to the most efficient performance, since all removal efficiencies are constantly higher than in the other two feeding schemes. Additionally, the SVI remains lower than 15 ml/g, implying ideal sludge settleability. Figure 8 shows the removal efficiencies for the three feeding ratios under influent flow distribution before the anaerobic selector. In all cases, organic substrate removal and nitrification are almost complete. However, denitrification, expressed by total nitrogen removal, and phosphate removal fluctuated. Total nitrogen removal ranged between 6-75% in the feeding ratio of 25/4/35, between 6-8% in the feeding ratio of 4/3/3 and between 8-83% in the feeding ratio of 6/25/15. Accordingly, phosphate removal spanned 27-54% in the feeding ratio of 25/4/35, between 42-71% in the feeding ratio of 4/3/3 and between 64-93% in the feeding ratio of 6/25/15. That means that increasing flow rate of influent raw wastewater in the initial stages of the plant increases the removal efficiency. Having detected the optimum feeding ratio (6/25/15), detection of the optimum hydraulic residence time (HRT) is the following step. Figure 8 shows that the highest removal efficiencies are recorded at HRTs of either 9 or 7 hrs, which correspond to an influent flow rate of 96 and 12 L/d. Since BOD removal represents the biodegradable part of organic pollution, NH 4 + -N removal stands for plant nitrification capability, PO P removal for desphosphatation capability and TN removal for plant denitrification capability, the mean removal efficiency calculated by using these data could be an indicator of the plant efficiency. SVI should also be taken into account as the settleability indicator. Comparing these data, the most efficient unit performance is recorded at HRT of 9 hrs and feeding ratio of 6/25/15 to the anaerobic selector, 2nd and 3rd anoxic tank respectively. This optimum steady state run will be stated as 14
15 A Modified UCT Method for Enhanced Biological Phosphorus Removal 4(6/25/15) for brevity reasons. This finding can be easily confirmed by data given in Table % Removal AN/DN2/DN3 6/25/ Q F (L/h) 8 % Removal AN/DN2/DN3 4/3/ Q F (L/h) 8 % Removal AN/DN2/DN3 25/4/35 BOD NH4N PO4P TN Q F (L/h) Figure 8. Removal efficiency for each feeding ratio under influent flow distribution before the anaerobic selector. 15
16 Vaiopoulou et al Flow pattern comparison In both flow patterns, whose influent flow distribution was accomplished according to the quota of 6/25/15 either before or after the anaerobic selector, removal efficiency of organic, nitrogenous and phosphorous contaminants was satisfactory for influent flow rates of 96, 12 and 144 L/d. Figure 9 presents the mean removal efficiency for organic, nitrogenous and phosphorus contaminants for the two different feed patterns. It is obvious that the feed distribution before the anaerobic selector leads to higher removal efficiency in comparison to the scheme of feed distribution after the anaerobic selector. The one and only exception is the total phosphorus removal, which is enhanced from 71% to 78%, when the feed is distributed after the anaerobic selector. However, orthophosphates removal is slightly hindered, whereas nitrification remains on the same removal levels (95-96%) for both feed patterns. % Mean removal efficiency before after COD BOD5 ΤΝ TKN NH4N ΤΡ PO4P Figure 9. Comparison of removal efficiency for both feed patterns (influent flow distribution before and after the anaerobic selector). The total phosphorous removal enhancement during the feed distribution pattern after the anaerobic selector is related to the phosphate release increase (Fig.1). Although the maximum phosphate release is performed in the first anoxic tank (DN1) in both feed patterns, total influent flow introduction to the anaerobic selector before step feeding results to a higher phosphate release, as shown in Figure 1. Higher phosphate release leads theoretically to greater phosphate uptake in the following aerobic conditions, and thus to higher removal efficiencies (Metcalf & Eddy, 23). However, influent and effluent phosphate concentrations are equal in both feed patterns. Therefore, the total phosphorous removal enhancement in the feed distribution pattern after the anaerobic selector may be attributed to the higher phosphate release due to the higher readily biodegradable carbon substances concentration available under anaerobic conditions, when the total raw wastewater flow enters the anaerobic tank. Readily biodegradable carbon is stored by PAOs in form of PHA, which is then used aerobically for phosphate uptake. The limited organic components concentration in the distributed flows, that is in this case (influent flow distribution after anaerobic selector) available for denitrification in the 16
17 A Modified UCT Method for Enhanced Biological Phosphorus Removal anoxic zones, is actually insufficient and responsible for denitrification decrease (Fig.9). ΡΟ4 3- -Ρ (mg/l) ,7 before after 11,3 8 7,7 4,1 4,5 2,8 3,5 1,5 1 1,4,4,3 IN AN DN1 AE1 DN2 AE2 DN3 AE3 OUT Figure 1. Orthophosphate concentration course along the unit for both flow patterns. The highest efficiencies per parameter and the lowest nitrate nitrogen effluent concentration for both flow patterns are marked bold within Table 3 to facilitate tracking of the flow pattern with the most efficient performance. It is quite interesting to note that the influent flow rate of 4 L/h (HRT of 9 hrs) distributed by the ratio of 6/25/15 provides the highest removal efficiency in both feed distribution patterns. The effluent nitrate nitrogen concentration is 7 and 6 mg/l for the steady state run of 4(6/25/15) with influent flow distribution before and after the anaerobic selector respectively. Since the steady state run of 4(6/25/15) with influent flow distribution before the anaerobic selector gathers the highest removal efficiencies and lowest nitrate nitrogen effluent concentration (highest denitrification capacity), retains the operational conditions and feed distribution pattern according to which the herein BNRAS system can perform optimally. 17
18 Vaiopoulou et al. Table 3. Removal efficiency and effluent NO - 3 -N concentrations for both step feeding patterns. Influent flow distribution BEFORE the anaerobic selector AFTER the anaerobic selector Removal (%) Q F (AN/DN2/DN3)= (6/25/15) [L/hr] (%Q F ) Q F (DN1/DN2/DN3)= (6/25/15) [L/hr] (%Q F ) COD BOD ΤΝ TKN NH 4 + -N ΤΡ PO 3-4 -P Average An unexpected effect noticed in the feed distribution pattern after the anaerobic selector was the extreme deterioration of the sludge settleability as indicated by the SVI measurements, which, however and most surprisingly, did not cause insufficient clarification. The mean SVI value in the last aerated tank under steady state condition was measured at 9 ml/g and 23 ml/g for feed distribution pattern before and after the anaerobic selector respectively (Fig.11). In the first case (SVI=9 ml/g), results indicate ideal sludge settleability characteristics, whereas in the latter case totally worrying (Jenkins et al., 1993) before after 228 SVI (ml/g) AE1 AE2 AE3 Figure 11. SVI values in aerobic tanks for feed distribution pattern before and after the anaerobic selector. 18
19 A Modified UCT Method for Enhanced Biological Phosphorus Removal Microscopic observations showed a wide variety and high numbers of protozoa and metazoa, such as Aspidisca costata, rotifers, Vorticela, Epistylis, Opercularia etc., as well as medium compact flocs with irregular shape, revealing a healthy sludge. Actually, the microscopic image of the unit sludge characteristics was similar in both flow schemes with the exception of the floc size, which was larger in the influent flow distribution after the anaerobic selector. Larger flocs are expected to increase sludge settleability because of their weight. The increased SVI finding might be attributed to the reduction of the influent sulfate to sulfide by sulfate reducing bacteria (SRB) under anaerobic conditions as observed previously in the same BNRAS plant when fed with a synthetic medium (Vaiopoulou et al., 27). It is suggested though, that the filamentous bacteria require a-two-month time to reach their cumulative length and thus, to cause bulking sludge (Jenkins et al., 1993; Vaiopoulou et al., 27). Other researchers showed that when sulfate reduction rates are high, maximum phosphate release is most of the times also high, because PAOs may utilize the acetate produced by SRB (Yamamoto-Ikemoto et al., 1998). Although their observations seem to explain our findings, further investigation is required to reach a confident explanation. It is also noticeable that SVI in the influent flow distribution pattern after the anaerobic selector attains the same average values in all aerated zones (AE1, AE2, AE3), which is probably related to the fact that all of them are fed with the effluent of the anaerobic selector. 4. Discussion Experiments on nutrients removal in a two denitrification stage UCT system with step feeding and influent flow distribution by 5% to the anaerobic tank and the rest to the second anoxic tank showed high removal efficiencies (Schlegel, 1992). According to these reported results, extensive reduction of carbon compounds was achieved, nitrogen removal attained values of 87%, phosphorus removal ranged between 7-8% and effluent nitrate nitrogen was low at 4.6 mg/l. A sludge thickener and a digester were used to provide a high sludge concentration in the recycle as well as VFAs to the anaerobic zone. As an initial treatment step, a primary sedimentation tank was included in the flow chart. A similar attempt was undertaken by Pai et al. resulting to an economically efficient removal of organic substrate and nutrients with highly clarified effluent (24). In this research work, 7-1% of the influent flow rate was fed to the initial anaerobic stage and the rest to the 1st and 2nd anoxic stage of the cascade. However, high influent flow rate introduction to the initial stages of a unit minimizes the effect of the step feeding process. In addition, the researchers fed their plant with a synthetic wastewater, although it can not lead to a realistic view of the unit performance, since some real wastewater composition parameters, such as COD and VFAs content, phosphorus load, ph etc, are of crucial importance for the effective biological removal of phosphorus (Mullkerins et al., 24) and most of the times can not be precisely simulated. Indeed, the authors have previously fed the herein presented experimental plant with synthetic wastewater, which led to filamentous bulking sludge and total system failure (Vaiopoulou et al., 27). The large number of BNRAS treatment methods, aiming at enhancing effluent characteristics and at optimizing the unit s efficiency, include external supply of organic substrate (usually acetic acid) (Satoh et al., 1992; Thomas et al., 23), 19
20 2 Vaiopoulou et al. reduction of sludge age (Rodrigo et al., 1996), chemicals addition for precipitation, metals addition (Schoenborn et al., 21), as well as minimization of nitrate and oxygen concentration entering the anaerobic tank (e.g. the UCT method) (de-bashan and Bashan, 24; Metcalf & Eddy, 23; Mullkerins et al., 24). However, these methods are not cost effective and require expertise when applied, e.g. waste sludge digestion for VFAs production in order to be added to the anaerobic tank for phosphate release enhancement. On the other hand, innovation in the feeding scheme may result to low cost and high efficiency removal. Having in mind that wastewater composition and feeding scheme determine the microbial synthesis, characteristics and thus, the unit performance and removal efficiency (Pai et al., 24; Wagner et al., 22; Zeng et al., 24), detection of the optimum feeding pattern could enhance effluent quality without extra costs. On this basis, the UCT method in combination with a three-stage denitrification cascade and the step-feeding strategy leads to no need for nitrified liquor recycle, reduces sludge recycle and volume requirements, eliminates nitrate/ oxygen intrusion to anaerobic conditions, optimizes organic carbon usage for denitrification and enhances effluent water characteristics. In particular, step-feeding configuration removes nitrogen by minimizing internal recycle and optimizing the carbon usage for denitrification (Görgün et al., 1996; Metcalf & Eddy, 23; Kayser et al., 1992; Schlegel, 1992). The cascade enhances effluent water quality with the minimum reactor volume, whereas provides operational safety, since whatever is left untreated, may be treated in the next stage (Kayser et al., 1992; Schlegel, 1992). Furthermore, a three-stage cascade has been proved to lead to low effluent concentrations with low volume needs, whereas a two-stage system is insufficient (Görgün et al., 1996; Lesouef et al., 1992). The removal efficiency of such a full-scale system, operating at a temperature of 12 C and without an anaerobic selector, depends on the sludge recycle rate and the flow-split percentages to the three anoxic tanks (Kayser et al., 1992). It has been proved that influent flow rate reduction to the last stages of the cascade is more efficient for nitrogen removal than recycle flow rate increase. Even though this system did not include an anaerobic selector, maximum phosphorus release was recorded in the first anoxic tank, which was afterwards taken up in the following aerobic tank. According to the same research work, the first anoxic tank of the cascade plays a crucial role in phosphorus removal. These conclusions are also confirmed by our results, since removal efficiency is maximized when the influent flow rate is distributed by 6% to the anaerobic selector, by 25% to the second and by 15% to the third anoxic tank, whereas under these operational conditions maximum phosphate release took place to the first anoxic tank. Schlegel recommends multiple stage units for influent ratio of organics to nitrogen (BOD 5 /TKN) above 5 (Schlegel, 1992), a value which attains the influent raw wastewater to our plant. In the same paper, a full-scale two-stage unit is presented, which includes primary sedimentation, an anaerobic selector and sludge digestion, for carbon, nitrogen and phosphorus removal. Phosphorus removal of 7-8% and effluent phosphorus concentration of 1.8 mg Ρ/L is achieved at hydraulic residence time 2 hours in the anaerobic selector, when organic acids, produced by sludge digestion, into the influent. Influent flow rate was distributed by 5% to the anaerobic
21 A Modified UCT Method for Enhanced Biological Phosphorus Removal selector and 5% to the second anoxic tank. The herein presented plant consisting of three stages, operating at HRT of 33 min in the anaerobic selector, without the addition of any extra organic substrate and influent flow distribution of 6/25/15 succeeds 93% phosphorus removal and effluent concentration of.2 mg Ρ/L. Operational results of a pilot-plant system with influent flow rate distribution by 7% to the anaerobic selector, by 2% to the first and by 1% to the second anoxic tank show 94% phosphorus removal, 75% total nitrogen removal και 87% organics removal (Pai et al., 24), whereas our experimental results for influent flow distribution rates of 6%, 25% and 15% to the anaerobic selector, the second and third anoxic tank respectively show 93% phosphate removal, 83% total nitrogen removal και 94% COD removal. Inclusion of an anaerobic selector to a plant configuration not only contributes to biological phosphorus removal, but also forms big and heavy flocs with excellent settleability (Metcalf & Eddy, 23). A review paper referring to UCT and Α 2 Ν method comparison states that UCT systems reduce excess sludge production, whereas in warm climates, such as the Greek one, they are more efficient than the Α 2 Ν systems (Hao et al., 21). Furthermore, recent experimental results confirmed the suggestion that nitrous oxide is produced by PHA-driven denitrification in activated sludge processes (e.g. A 2 N) (Meyer et al., 25). However, a comparative study of the herein presented system and a two-sludge system could actually give more efficient information. Therefore, such experiments are conducted currently in our laboratory. Comparing the design parameters of the presented unit with other wide-spread methods, the sludge retention time (SRT=1d) and the hydraulic residence times in the anaerobic selector (.55 h), in the anoxic (1.46 h) and aerobic zone (3.13 h) are quite short. No internal recycle is necessary, whereas recycle flow rate is relatively low at 1% of the influent wastewater flow rate. The required volume per population equivalent (PE) for an influent flow rate of 96 L/d is calculated at 68 L/PE, when assuming the daily wastewater production per population at about 185 L. This volumetric requirement per population equivalent is lower in comparison with other wastewater treatment systems and may be further reduced by increasing the treatment stages. Construction costs are limited respectively to volumetric needs reduction per population equivalent. It must be clearly stated that the residence time distribution (RTD) of the presented pilot plant (data not shown here) plays a beneficial role regarding its enhanced response to the existing first order kinetics, due to the limited axial dispersion, and to the filaments suppression. RTD experiments revealed that the Bodenstein number (Bo) ranged from 5 to 6 (dispersion model), whereas the cascade number (N) has been determined between 2.5 and 3 (tanks in series model) in the pilot-scale plant. From a kinetic point of view, the plant behaves operationally as if a cascade of three continuous flow stirred tank reactors (CFSTR) and consequently, as if a plug flow reactor (PFR). The favorable plant characteristics, which are responsible for high removal efficiencies and good sludge settleability, are attributed to this PFR behavior. 21
22 Vaiopoulou et al. In particular, the sludge volume index was less than 15 ml/g for influent wastewater distribution before the anaerobic selector, which means that the sludge settleability is excellent and may be added to the unit s advantages. Sludge formation with good settleability should not be only attributed to the anaerobic selector, but also to the previously mentioned operational behavior of the plant. Thus, the proposed configuration strongly supports the metabolic selection of floc-forming microorganisms resulting in excellent activated sludge settling properties. The fact that the denitrification activity, and thus efficiency, was several times recorded below 83% is grounded on the experimental practice and mostly on the inconsistency of the influent carbon to nitrogen (C/N) ratio. Specifically, the piping system was so designed that unintentional oxygenation and anoxic conditions disruption is kept at a minimum. However, maintenance of a large quantity of wastewater, even under low temperature, inevitably leads to organics biodegradation, which may reach and exceed 3% under storage (4-5 days). Therefore, influent C/N ratio is sometimes so low that it is inefficient for denitrification. In case of full-scale application of the presented plant, where flow of influent wastewater will be constant and the C/N ratio constantly high, denitrification efficiency could reach higher values in the second and third anoxic tank. 5. Conclusions The main characteristics of the proposed optimum plant configuration are: 1. The initial anaerobic tank helps select phosphate accumulating organisms, according to the EBPR technique, as well as floc-formers over filamentous bacteria. 2. A cascade of three identical bioreactor pairs, where each of them consists of two separate tanks with anoxic and oxic (aerobic) conditions. This cascade of three stages is expected to yield to a potential (theoretical) removal efficiency of total nitrogen around 83%, when sludge recycle ratio is equal to the influent flow rate. Multiple stage cascades also offer the operational safety that what leaves a stage untreated can be removed in the next stage. 3. The step-feeding process. Influent flow rate is distributed to anaerobic or anoxic tanks in order to provide cheap organic substrate for phosphate release or denitrification, as well as to transform these tanks into selectors of floc-formers over filaments. 4. The primary sedimentation tank is absent, which means that organic substrate is maintained for biological phosphate removal and denitrification. 5. The sludge recycle from the clarifier is introduced to the anaerobic selector via the first anoxic tank, resulting in nitrate elimination before entering the anaerobic selector, and thus, in real anaerobic conditions in the anaerobic selector, to sludge recycle flow minimization and to supply of the anaerobic selector with biomass. 6. The limited axial dispersion in the cascade (plug flow) due to the narrow spectrum of the Residence Time Distribution is ideal for first order kinetics, which in combination to the anaerobic selector may also suppress filamentous bacteria proliferation. 22
23 A Modified UCT Method for Enhanced Biological Phosphorus Removal The highest removal efficiencies, the most favorable sludge characteristics and the lowest effluent concentrations were observed for influent flow distribution before the anaerobic selector at HRT of 8.9 hrs and ratios of 6% to the anaerobic selector, 25% to the second and 15% to the third anoxic tank. In particular, organics removal received values of 94% and 98% for COD and BOD5 respectively, whereas phosphate removal of 93%. Nitrogen removal was recorded at 83% as total nitrogen, 94% as total Kjedahl nitrogen and 99% as ammonium nitrogen. Effluent concentrations were measured at 43 mg COD/L, 6 mg BOD 5 /L,.7 mg NH 4 + -N/L, 7 mg NO 3 - -N/L, 4.4 mg ΤΚN/L,.2 mg NO 2 - -N/L and.2 mg ΡΟ Ρ/L. SVI was satisfactory at 14 ml/g. Acknowledgements REVOIL S.A. and Alexander S. Onasis Foundations are gratefully acknowledged for supporting financially Mrs E. Vaiopoulou during her doctoral studies. References 1. Wagner, M., Loy, A., Nogueira, R., Purkhold, U., Lee, N. and Daims, H., (22) Antonie van Leeuwenhoek 81, Seviour, R.J., Mino, T., Onuki, M., (23) FEMS Microbiology Reviews 27, Mullkerins, D., Dobson, A.D.W. and Colleran, E., (24) Environment International 3, Metcalf & Eddy, Wastewater engineering: treatment and reuse, Rev. by Tchobanoglous G., Burton F.L., Stensel H.D., 4th edition, McGraw Hill (23) 5. Schlegel, S., (1992) Wat. Sci. and Technol. 25(4-5), Ekama, G.A. and Wentzel, M.C., (1999) Wat. Sci. Technol. 39(6), Görgün, E., Artan, N., Orhon, D. and Sözen, S., (1996) Wat. Sci. and Technol. 34(1-2), Pai, T.Y., Tsai, Y.P., Chou, Y.J., Chang, H.Y., Leu, H.G. and Ouyang, C.F., (24) Chemosphere 55, Vaiopoulou, E., Melidis, P. and Aivasidis, A., (27) Desalination 211, Zeng, R.J., Yuan, Z. and Keller, J., (24) Reviews in Environmental Science & Bio/Technology 3, Vaiopoulou, E., Melidis, P. aand Aivasidis, A., (27) Desalination 213, APHA/AWWA/WPCF, 1998 Standard methods for the examination of water and wastewater, 2th edition, American Public Health Association, Washington, USA. 13. Kayser, R., Stobbe, G. and Werner, M., (1992) Wat. Sci. Technol. 25(6), Jenkins, D., Richard, M.G. and Daigger, G.T., Manual on the causes and control of activated sludge bulking and foaming, Lewis Publishers, Washington, USA (1993) 15. Yamamoto-Ikemoto, R., Matsui, S., Komori, T. and Bosque-Hamilton, E.K., (1998) Wat. Sci. and Technol. 37(4-5), Satoh, H., Mino, T. and Matsuo, T., (1992) Wat. Sci. Technol. 26, Thomas, M., Wright, P., Blackall, L., Urbain, V. and Keller, J., (23) Wat. Sci. Technol. 47,
24 Vaiopoulou et al. 18. Rodrigo, M.A., Seco, A., Penya-roja, J.M. and Ferrer, J., (1996) Wat. Sci. Technol. 34, Schoenborn, C., Bauer, H.-D. and Roeske, I., (21) Wat. Res. 36, de-bashan, L.E. and Bashan, Y., (24) Wat. Res. 38, Lesouef, A., Payraudeau, M., Rogalla, F. and Kleiber, B., (1992) Wat. Sc. Tech. 25(6), Hao, X., van Loosdrecht, M.C.M., Meijer, S.C.F. and Qian, Y., (21) Wat. Res. 35, Meyer, R.L., Zeng, R.J., Giugliano, V. and Blackall, L.L., (25) FEMS Microbiology Ecology 52,
Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc. [email protected] 201 529 5151 X 7167
Nutrient Removal at Wastewater Treatment Facilities Nitrogen and Phosphorus Gary M. Grey HydroQual, Inc. [email protected] 201 529 5151 X 7167 1 Agenda Nitrification and Denitrification Fundamentals
THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL
THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL ABSTRACT Timur Deniz, Ph.D., Thomas W. Friedrich, P.E.
1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005
1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005 This is an open-book exam. You are free to use your textbook, lecture notes, homework, and other sources other than the internet.
Phosphorus Removal in Wastewater Treatment
RESEARCH & DEVELOPMENT REPORT NO. Phosphorus Removal in Wastewater Treatment (Final Report) Research and Development Section Electrical & Mechanical Projects Division Nov 2013 Final Report endorsed by
During the past decade, the city of
An Advanced Pollution Control Facility s Conversion to Four-Stage Bardenpho to Improve Biological Nitrogen Removal Timur Deniz, Thomas W. Friedrich, and John Milligan During the past decade, the city of
Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key
Unit 1 Process Control Strategies Exercise Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key 1. What are the six key monitoring points within the activated sludge process? Ans:
5.1.3 Model of biological phosphorus removal
196 5.1.3 Model of biological phosphorus removal 5.1.3.1 Enhanced cultures Based on the concepts presented in the previous section, a model was developed at the university of Cape Town (UCT) to describe
WEFTEC.06. *Corresponding author Department of Civil and Environmental Engineering, The University of Western Ontario
Performance of Aerobic MBR Treating High Strength Oily Wastewater at Mesophilic Thermophilic Transitional Temperatures R. Kurian, G. Nakhla* Earth Tech Canada Inc., Thornhill, L3T 7Y6 Ontario *Corresponding
Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008
Basic Nutrient Removal from Water Beta Edition Presented by Paul Krauth Utah DEQ Salt Lake Countywide Watershed Symposium October 28-29, 2008 Presentation Outline Salt Lake County waters / 303(d) listings
Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD
Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD Trevor Ghylin, PE PhD Outline Background Case Study: Sterno, Sweden (~1.8 MGD) 65% Aeration Energy Reduction Case Study:
Bio-P Removal- Principles and examples in MI and elsewhere S. Joh Kang, Ph.D., P.E. Tetra Tech, Inc. Ann Arbor, MI 2010 Presentation Outline Optimization of Chemicals and Energy Bio-P Removal - Review
Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries
Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries C. Chiemchaisri Department of Environmental Engineering, Kasetsart University
ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT
ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT ABSTRACT by Vikram M Pattarkine*, Randall C Chann**, Charles E Tharp** *Brinjac Engineering Inc, 114 North 2 nd Street, Harrisburg, PA 1711
Sewerage Management System for Reduction of River Pollution
Sewerage Management System for Reduction of River Pollution Peter Hartwig Germany Content page: 1 Introduction 1 2 Total emissions 3 3 Discharge from the wastewater treatment plants 4 4 Discharge from
CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES
CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES 8-1. General. Upgrading of wastewater treatment plants may be required to handle increased hydraulic and organic loadings to meet existing effluent quality
IMPACT OF CHEMICALS ADDITION IN WATER/WASTEWATER TREATMENT ON TDS CONCENTRATION AND SLUDGE GENERATION Jurek Patoczka, PhD, PE Hatch Mott MacDonald 27 Bleeker Str., Millburn, NJ 07041 (973) 912 2541 [email protected]
Biological Phosphorus Removal Activated Sludge Process in Warm Climates
Biological Phosphorus Removal Activated Sludge Process in Warm Climates CaoYe Shi Publishing London* New York Contents Preface Acknowledgements About the author Nomenclature ix xi xiii xv Chapter 1 General
OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.
OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM ABSTRACT MIDDLEBURY, VT Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc. The Middlebury Wastwater Treatment Plant, located
TABLE OF CONTENTS 2. PHOSPHORUS AND NITROGEN IN WASTEWATER 3. PHOSPHORUS AND NITROGEN REMOVAL MECHANISM 4. PROCESS REQUIREMENT AND CONTROL FACTOR
TABLE OF CONTENTS Submittal 1. INTRODUCTION 2. PHOSPHORUS AND NITROGEN IN WASTEWATER 3. PHOSPHORUS AND NITROGEN REMOVAL MECHANISM 3.1 Chemical Phosphorus Removal 3.2 Biological Phosphorus Removal 3.2.1
Phosphorus Removal. Wastewater Treatment
Phosphorus Removal In Wastewater Treatment by Derek Shires (512) 940-2393 [email protected] Why do we care? Eutrophication of surface water - Especially reservoirs Maximum agronomic uptake - Limiting
Best Practice Guide NO. BPGCS002. Wastewater Treatment Activated Sludge Process
Best Practice Guide NO. BPGCS002 Wastewater Treatment Activated Sludge Process The following is intended to provide a first check for those involved in the operation, management and monitoring of the activated
Wastewater Nutrient Removal
Wastewater Nutrient Removal An overview of phosphorus and nitrogen removal strategies Presented by: William E. Brown, P.E. Peter C. Atherton, P.E. Why are nutrients an issue in the environment? Stimulates
NUTRIENT REMOVAL WASTEWATER TREATMENT CLIFFORD W. RANDALL, PHD EMERITUS PROFESSOR VIRGINIA TECH
NUTRIENT REMOVAL WASTEWATER TREATMENT CLIFFORD W. RANDALL, PHD EMERITUS PROFESSOR VIRGINIA TECH The Impacts of Excess Nutrients Nitrogen and Phosphorus Are the nutrients that cause over fertilization of
True Confessions of the Biological Nutrient Removal Process
True Confessions of the Biological Nutrient Removal Process N itrogen and phosphorus are essential growth elements for microorganisms used in wastewater treatment; therefore, during all biological treatment,
Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies
Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies Yasar Avsar 1, Hussein Tarabeah 2, Shlomo Kimchie 3, Izzet Ozturk 4, Hadi Naamneh 2 1 Yildiz Technical
A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER
A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER ABSTRACT Leonard P. Seed, M.Sc., P.Eng., Enpar Technologies Inc. * Daren D. Yetman, A.Sc.T., Enpar Technologies
MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting 18-21 February 2013 Siem Reap, Combodiaby
MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting 18-21 February 2013 Siem Reap, Combodiaby enforcement DIVISION DEPARTMENT OF ENVIRONMENT, MALAYSIA
Research Article. Removal of nitrogen and phosphorus from municipal wastewater using intermittent cycle moving bed biofilm reactor (ICMBBR)
Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research, 2015, 7(6):979-987 Research Article ISSN : 0975-7384 CODEN(USA) : JCPRC5 of nitrogen and phosphorus from municipal wastewater
Module 17: The Activated Sludge Process Part III
Wastewater Treatment Plant Operator Certification Training Module 17: The Activated Sludge Process Part III Revised October 2014 This course includes content developed by the Pennsylvania Department of
WISCONSIN WASTEWATER OPERATORS ASSOCIATION
Integrity. People. Knowledge. WISCONSIN WASTEWATER OPERATORS ASSOCIATION ANNUAL CONFERENCE GREEN BAY Resources. MEETING LOW LEVEL PHOSPHORUS LIMITS BY CHEMICAL ADDITION WHAT IS PHOSPHORUS Atomic # 15 Electron
Appendix F Use of spill basin to further reduce final effluent variability - report
Appendix F Use of spill basin to further reduce final effluent variability - report yry (November 2008) Use of the emergency basin to further reduce the variability of final effluent quality. Report prepared
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
Advanced Wastewater Treatment Process
7 th Workshop on Greenhouse Gas Inventories in Asia Possibly Co-benefit? Advanced Wastewater Treatment Process Tomonori ISHIGAKI Dept. of Environmental Solution Technology Ryukoku University, Japan Introductory
Biological Wastewater Treatment
Biological Wastewater Treatment This article briefly discusses the differences between aerobic and anaerobic biological treatment processes and subsequently focuses on select aerobic biological treatment
The Use of Simulation Modelling for Optimisation of Phosphorus Removal in Sewage Treatment under Varying Influent Loading
Research Journal of Applied Sciences, Engineering and Technology 6(24): 4663-4670, 2013 ISSN: 2040-7459; e-issn: 2040-7467 Maxwell Scientific Organization, 2014 Submitted: March 12, 2013 Accepted: April
Biological nutrient removal by a sequencing batch reactor (SBR) using an internal organic carbon source in digested piggery wastewater
Bioresource Technology 96 (25) 7 1 Biological nutrient removal by a sequencing batch reactor (SBR) using an internal organic carbon source in digested piggery wastewater D. Obaja, S. Mace, J. Mata-Alvarez
BALANCING REDOX EQUATIONS. Each redox equation contains two parts -- the oxidation and reduction parts. Each is balanced separately.
C & EE 255B Prof. M. K. Stenstrom Winter 2015 BALANCING REDOX EQUATIONS Balancing redox (oxidation-reduction) equations is a simple and very useful technique of performing balances from empirical equations
Engineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Advanced
Appendix 2-1. Sewage Treatment Process Options
Appendix 2-1 Sewage Treatment Process Options Table of Contents Appendix 2-1 Sewage Treatment Process Options 1 Introduction...1 2 Chemically Enhanced Primary Treatment (CEPT) Processes...2 2.1 CEPT with
Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service
Experts Review of Aerobic Treatment Unit Operation and Maintenance Bruce Lesikar Texas AgriLife Extension Service Overview Overview of Aerobic Treatment Units Installing for accessibility to system components
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology
Development of Advanced Wastewater Treatment and Reclamation System
14 Development of Advanced Wastewater Treatment and Reclamation System TAKESHI TERAZAKI *1 HOZUMI OTOZAI *2 KOSUKE SHIGIISHI *2 HIDEO SUZUKI *3 HIROSHI NAKASHOJI *4 HIROYUKI KAWAMOTO *5 Recycling and the
Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence
Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence Christina M. Edvardsson and David R. Spears, MicroSepTec, Inc., 2661 Cabot Road, Laguna Hills, CA 92653
Application of Moving Bed Biofilm Process for Biological Organics and Nutrients Removal from Municipal Wastewater
American Journal of Environmental Sciences 4 (6): 682-689, 28 ISSN 1553-345X 28 Science Publications Application of Moving Bed Biofilm Process for Biological Organics and Nutrients Removal from Municipal
GUIDELINES FOR LEACHATE CONTROL
GUIDELINES FOR LEACHATE CONTROL The term leachate refers to liquids that migrate from the waste carrying dissolved or suspended contaminants. Leachate results from precipitation entering the landfill and
Phosphorus Removal. P.F. Strom, 2006; do not copy without written permission.
Phosphorus Removal Dr. Peter F. Strom, Professor Dept. of Environmental Sciences Cook College, Rutgers University 14 College Farm Road New Brunswick, NJ 08901-8551 (732) 932-8078; [email protected]
Enhanced Biological Phosphorus Removal Using Crude Glycerol (from biodiesel production) in lieu of VFA Supplementation
Enhanced Biological Phosphorus Removal Using Crude Glycerol (from biodiesel production) in lieu of VFA Supplementation PNCWA October 23, 2012 Boise, Idaho Erik R. Coats, PE, Ph.D. University of Idaho Zach
MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC
Introduction MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC Aeration systems for conventional wastewater activated sludge
Example Calculations Evaluation for Fine Bubble Aeration System. Red Valve Company, Inc. 700 NORTH BELL AVENUE CARNEGIE, PA 15106-0548
Revision Date 6/10/02 9:52 Red Valve Company, Inc. 700 NORTH BELL AVENUE CARNEGIE, PA 15106-0548 PHONE (412) 279-0044 FAX (412) 279-5410 Red Valve Representative Sample Air Diffuser Calcs.xls Input Data
PROPAK AquaBio Complete Water Restoration Systems
PROPAK AquaBio Complete Water Restoration Systems Conserving natural resources and lowering operating expenses is no longer an option, it is a necessity. Water, sewer and discharge fees are continuing
Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.
II. PROCESS OVERVIEW Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system. II.1. Wastewater Generation A typical
SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY
SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY Adel Bassyouni, HDR Engineering, Guillermo Garcia, HDR Engineering, Don Mc Dermott, Viejas Public Works Department
REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS
International Journal of Engineering Inventions ISSN: 2278-7461, www.ijeijournal.com Volume 1, Issue 7 (October2012) PP: 44-50 REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS Dr. C.R.Ramakrishnaiah
Nutrient removal from wastewater by aerobic sludge
Nutrient removal from wastewater by aerobic sludge Master of Science Thesis in the Master s Programme Environmental Measurements and Assessments SHUANG QI Department of Civil and Environmental Engineering
Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS
Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS The evolution continues in decentralised wastewater technology... The Process Decentralised wastewater treatment systems are defined
Evaluation of Practical Technology-Based Effluent Standards for Phosphorus and Nitrogen in Illinois
October 18, 2011 PREPARED FOR: Illinois Association of Wastewater Agencies c/o Mr. Tim Bachman Urbana & Champaign Sanitary District 1100 East University Avenue P.O. Box 669 Urbana, Illinois 61803-0669
Brewery Wastewater: 2010 Water and Wastewater Conference. 11.02.2011 Page 1
Brewery Wastewater: Solutions for the Problem By Fred M. Scheer 2010 Water and Wastewater Conference Madison, WI 11.02.2011 Page 1 vr74 What We Will Discuss: Biochemical i Oxygen Demand (BOD): Where does
ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.
Summary ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc. The rendering industry has a significant positive impact on environmental quality.
Removing Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides
ANAEROBIC TREATMENT FOR SANA'A WASTEWATER USING UASB REACTOR PILOT PLANT
------------------------------------------------------------------------------------------------------------------------------- Full length Research Paper -------------------------------------------------------------------------------------------------------------------------------
POTW PHOSPHORUS REMOVAL PROCESSES
POTW PHOSPHORUS REMOVAL PROCESSES Ohio Lake Erie Phosphorus Task Force - December 20, 2007 ROBERT M. BONNETT, PE Northeast Ohio Regional Sewer District OUTLINE SOURCES AND FORMS IN WASTEWATER TYPICAL POTW
Sludge Stabilization Sustainability of Aerobic Digestion Processes Bryen Woo EGCE 597: Research Paper
ABSTRACT Sludge Stabilization Sustainability of Aerobic Digestion Processes Bryen Woo EGCE 597: Research Paper Treating wastewater is very important to protect the quality of human life and preserve water
WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )
Page 1 of 76 1.0 PURPOSE The purpose of the Wastewater Treatment System is to remove contaminates from plant wastewater so that it may be sent to the Final Plant Effluent Tank and eventually discharged
NUTRIENT REMOVAL FROM SECONDARY EFFLUENT BY ALUM FLOCCULATION AND LIME PRECIPITATION*
University of Wisconsin Engineering Experiment Station Reprint Number 708 Int. J. Air Wat. Poll. Pergamon Press 1964. Vol. 8, pp. 487-500. Printed in Great Britain. NUTRIENT REMOVAL FROM SECONDARY EFFLUENT
aquateam Aquateam - Norwegian Water Technology Centre A/S Report no: 02-051 Project no: O-02033 Project manager: Dr. Bjørn Rusten.
Feasibility study of biological wastewater treatment plants with Salsnes Filter fine mesh sieve primary treatment compared to plants without primary treatment Aquateam - Norwegian Water Technology Centre
Unit 1. Physical, chemical and biological Characteristics of Wastewater
The Islamic University of Gaza- Civil Engineering Department Advanced Sanitary Engineering- ECIV 5325 Unit 1. Physical, chemical and biological Characteristics of Wastewater Based on Dr. Fahid Rabah lecture
Floating Treatment Wetland Technology: Nutrient Removal from Wastewater
Floating Treatment Wetland Technology: Nutrient Removal from Wastewater This case study illustrates the Floating Island International (FII) patented floating treatment wetland (FTW) technology and its
SECONDARY TREATMENT ACTIVATED SLUDGE
SECONDARY TREATMENT ACTIVATED SLUDGE Activated sludge is another biological process used to remove organics from wastewater. Like the trickling filter, activated sludge processes are used to grow a biomass
Mainstream Deammonification: Current Projects and Status. S. Murthy, B. Wett and M. van Loosdrecht
Mainstream Deammonification: Current Projects and Status S. Murthy, B. Wett and M. van Loosdrecht Incentives for Mainstream Deammonification? Carbon redirection from aerobic treatment to anaerobic digestion
Iowa DNR Wastewater Treatment Technology Assessment No. 09-01
Iowa DNR Wastewater Treatment Technology Assessment No. 09-01 Evaluation of Full-Scale LemTec Biological Treatment Facilities for Wastewater Design Review Considerations by the Iowa Department of Natural
MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE
MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE Jeff Peeters, P.Eng. ZENON Environmental Inc. SAWEA 2005 Workshop Al-Khobar Holiday Inn Hotel, Saudi Arabia November 29, 2005 Presentation outline
Under the direction of the MOP 11 Subcommittee of the Technical Practice Committee
Operation of Municipal Wastewater Treatment Plants WEF Manual of Practice No. 11 Chapter 22 Biological Nutrient Removal Processes Sixth Edition Prepared by the Operation of Municipal Wastewater Treatment
Activated Sludge Microbiology Problems And Solutions. Real Science. Trusted Process. Proven Success.
Activated Sludge Microbiology Problems And Solutions Presentation Outline Poor Floc Formation, Pin Flocs and Dispersed Growth Toxicity Nitrification and Denitrification Problems Nutrient deficiency and
Chemistry at Work. How Chemistry is used in the Water Service
Chemistry at Work How Chemistry is used in the Water Service WATER TREATMENT Everyday, more than 100 water treatment works in Northern Ireland put approximately 680 million litres of water into the supply
Technical Publication. Title: Using Online Analyzer for Optimizing Chemical Phosphorus Removal Process in Municipal Wastewater Treatment
Technical Publication Title: Using Online Analyzer for Optimizing Chemical Phosphorus Removal Process in Municipal Wastewater Treatment ASA Publication #211 Presented at: WEAO Technical Conference Ottawa,
UASB reactor for domestic wastewater treatment at low temperatures: a comparison between a classical UASB and hybrid UASB-filter reactor
UASB reactor for domestic wastewater treatment at low temperatures: a comparison between a classical UASB and hybrid UASB-filter reactor B. Lew, S. Tarre, M. Belavski and M. Green Faculty of Civil and
Bioremediation. Introduction
Bioremediation Introduction In the twentieth century, the ever increase in the global human population and industrialization led to the exploitation of natural resources. The increased usage of heavy metals
Phosphorous Reduction in the Assabet River
Phosphorous Reduction in the Assabet River A Major Qualifying Project Report: Submitted to the Faculty Of the WORCESTER POLYTECHNIC INSTITUTE In partial fulfilment of the requirements for the Degree of
Operation and Maintenance of Onsite Waster Systems in Maryland. A growing challenge for the industry and regulators
Operation and Maintenance of Onsite Waster Systems in Maryland A growing challenge for the industry and regulators Operation and Maintenance of Onsite Waster Systems in Maryland New law and regulations
Glossary of Wastewater Terms
Glossary of Wastewater Terms Activated Sludge Sludge that has undergone flocculation forming a bacterial culture typically carried out in tanks. Can be extended with aeration. Advanced Primary Treatment
Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media
Enhanced Organic Precursor Removals Using Aged Media Page 1 Enhanced Organic Precursor Removals Using Aged Media O b j e c t i v e s The main goals of this project was to evaluate the dissolved organic
Water and Wastewater. Sample Collection and Analysis
Water and Wastewater Sample Collection and Analysis December 2011 Introduction Accurate testing of drinking water is crucial to maintaining the health and safety of Islanders who rely on this resource.
Site Visit Report. MEAT PROCESSING FACILITY COD Reduction. Industrial Assistance Section Assessment Team
N.C. Division of Pollution Prevention and Environmental Assistance North Carolina Department of Environment and Natural Resources Site Visit Report MEAT PROCESSING FACILITY COD Reduction Industrial Assistance
An introduction to EPAS
An introduction to EPAS Process-technical advice for your water and wastewater treatment plant In response to the growing demand for professional environmental process and technological advice, EPAS (Eco
WASTEWATER TREATMENT PERFORMANCE AND COST DATA TO SUPPORT AN AFFORDABILITY ANALYSIS FOR WATER QUALITY STANDARDS
WASTEWATER TREATMENT PERFORMANCE AND COST DATA TO SUPPORT AN AFFORDABILITY ANALYSIS FOR WATER QUALITY STANDARDS Prepared for: Michael Suplee, Ph.D. Montana Department of Environmental Quality Helena, Montana
Nutrient removal from wastewater by wetland systems
Nutrient removal from wastewater by wetland systems Ishadeep Khanijo Abstract: For past so many years wetlands have served functions like providing habitat for aquatic and terrestrial plants and animals,
Alberta Onsite Wastewater Management Association Installer Training Program
Alberta Onsite Wastewater Management Association Installer Training Program OWTS 100 Overview and Principles of Wastewater Treatment Systems Brief Review of All Types of Systems 1. Know the general principles
ENGINEERING REPORT Sewage Treatment System
CIVIL & STRUCTURAL ENGINEERING CONSULTANTS 7A Barbados Avenue, Kingston 5, Jamaica, Tele: (876) 754-2154/5 Fax: (876) 754-2156 E-mail: [email protected] GORE FLORENCE HALL DEVELOPMENT FCS # 0827/76/C
The Sewage Plant. The Original! Fully biological. Small sewage. wastewater treatment for. new construction. & retrofitting
The Sewage Plant The Original! Fully biological wastewater treatment for new construction & retrofitting Ssb Small sewage treatment plant AQuato stabi-kom AQUATO STABI-KOM THE NEW GENERATION AMONG THE
TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa
TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa Tallinn is the capital of Estonia. It has approximately 450,000 inhabitants and the town area is about 150 km 2. Tallinn Water Ltd., owned by the City
Module 23 : Tertiary Wastewater Treatment Lecture 38 : Tertiary Wastewater Treatment
1 P age Module 23 : Tertiary Wastewater Treatment Lecture 38 : Tertiary Wastewater Treatment 2 P age 23.1 Introduction Secondary treatment removes 85 to 95 percent of BOD and TSS and minor portions of
Wastewater Design & Best Practices
Wastewater Design & Best Practices American Meat Institute Conference on Worker Safety, Human Resources and the Environment Kansas City, Missouri Brian Mulinix, P.E. Brian Bakke, P.E. HDR Engineering,
ANAEROBIC/ANOXIC TANKS
PROCESS DESCRIPTION In the anaerobic/anoxic tanks, wastewater is prepared for further treatment in the biological reactors. Denitrification and luxury uptake of phosphorus take place by mixing a food source
SIMBA - Simulation of biological wastewater systems
SIMBA 6 SIMBA - Simulation of biological wastewater systems The simulation system SIMBA is a versatile software for the modelling and dynamic simulation in the field of wastewater engineering. In its version
POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Technologies for Water Pollution Control - Wang Jianlong
TECHNOLOGIES FOR WATER POLLUTION CONTROL Wang Jianlong Tsinghua University, Beijing, 100084, Poeples Republic of China. Keywords: Activated sludge, Aerobic treatment, Anaerobic treatment, Biological treatment,
6.2 ADVANCED WASTEWATER TREATMENT PROCESS PERFORMANCE
6.1 INTRODUCTION Wastewater treatment process considerations must be updated from the 2002 Wastewater Facilities Plan and the 2003 Wastewater Facilities Plan Amendment to account for the extremely low
This example of a completed sampling plan worksheet has been included to illustrate the information
APPENDIX B EXAMPLE OF A COMPLETED SAMPLING PLAN WORKSHEET This example of a completed sampling plan worksheet has been included to illustrate the information necessary to document a sampling program for