Güntner Competence. Air Conditioning. Hotel. City Mall EDP. University
|
|
|
- Ashley McDaniel
- 10 years ago
- Views:
Transcription
1 Güntner Competence Air Conditioning EDP Hotel City Mall Bank Production University
2 2 Güntner Competence Air Conditioning 3 Güntner offers its customers a wide range of condensers and drycoolers. This product range and individual selection via Güntner s GPC software produce diverse solution options for every customer requirement. Heinz Jackmann, Head of Product Management The requirement for air conditioning has increased sharply over the past two decades. A service provider society with numerous administration centres has emerged in Central Europe in particular. First and foremost, insurance companies, banks, telecommunication companies and Internet operators have developed very fast. A similar service provider society will also emerge in other countries. Güntner, among others, has shaped this market as the leading manufacturer of condensers and drycoolers. Güntner products can be individually configured and produced for every area of application. This ensures the ideal drycooler for your requirements. Our Technical Sales supports you with comprehensive consulting on the phone or personally on-site. Competent. Reliable. Personal.
3 4 Güntner Competence Air Conditioning 5 Achieving objectives together with partnership-based consulting Individual project situation Decision on requests/planning Quote Sales strategy Product strategy Take advantage of Güntner s extensive experience. With specific application know-how and innovative products we can work out optimum solutions together with you. We project the heat exchangers according to your specifications with reliable data and advise you on the best possible selection, equipping and number of units. Our technical sales staff support you in your search for the optimum concept, and also provides you with the required technical data for your planning.
4 6 Güntner Competence Air Conditioning 7 Quickly and safe Calculate thermodynamically & prepare offers The Güntner Product Calculator GPC configuration software allows you to quickly and easily configure the right unit for your individual application. Simply enter the required basic data in the convenient entry screen on the GPC. An exact thermodynamic configuration is performed and a selection of the suitable units is provided while considering your selected operating conditions and selected accessories. You consequently choose the optimum unit and the GPC generates a data sheet with technical data, dimensions, weights and prices for you. Download your free Güntner Product Calculator (GPC) at: Use our GPC for selecting evaporators, condensers, air coolers, drycoolers, control units and switch cabinets! Possible input data: Brine exit temperature Air temperature Accessories Output Brine entry temperature Thermodynamic calculation = optimum unit selection for every application case Liquid recirculation Subcooling temperature Sound pressure level Medium
5 8 Güntner Competence Air Conditioning 9 Large orders for different markets Westfield White City Shopping Centre, London Güntner drycoolers Güntner has 6 production sites on 3 continents, and can therefore meet local requirements and regulations, and guarantee you short delivery times and cost-efficient transporting on all markets. Our production sites are strategically located and have the appropriate capacity to supply you on schedule with high volume orders. Güntner has completed numerous large-scale projects around the globe over the past few decades.
6 10 Güntner Competence Air Conditioning 11 Global presence As your partner we support you around the entire globe! You will find us at over 50 locations in almost every important production and trade centre in Europe, the Americas and Asia. We speak the language of the market and understand regional laws and mentalities. Production site, Russia Head Office, Germany Production site, Hungary Production site, Mexico Production site, Indonesia Production sites Local offices Distribution area Production site, Brazil A global community of experts
7 12 Güntner Competence Air Conditioning 13 High demand reliable products Güntner only uses the high-grade materials of certified manufacturers in producing its heat exchangers. These are processed on modern machinery into high-quality and optically appealing products. In addition to cost-effectiveness, safety of staff and environmental protection are also high priority Güntner corporate goals. Quality claim The Güntner quality claim covers all work steps from planning to development, right through to production. Tests Güntner heat exchangers are continuously tested and certified by independent institutions: Supplier management The selection of qualified suppliers is a decisive criterion for Güntner in producing its top quality products. Only the tested products of certified manufacturers are used. Quality management Comprehensive quality management is applied at all our production sites. We consequently guarantee that the production process and the end products are continuously checked. DIN ISO 9001 GOST UL CE Eurovent VDE TÜV HACCP
8 14 Güntner Competence Air Conditioning 15 Series GFD / GVD V-coil drycoolers / V-coil condensers kw GFH / GFV Horizontal / vertical drycoolers kw Big capacity with small set-up area - V-shape heat exchanger set-up - Maximum number of fans per unit Classic, robust structure, proven for decades - Design for horizontal and vertical set-up - High power and sound spectrum - Suitable for all applications GFW / GVW Drycoolers / condensers kw RFH / RVH Drycoolers / condensers kw High power density, low installation height - With larger systems several devices can be space-savingly linked together on one steel frame. With radial fans for indoor set-up - For indoor set-up and connection to air ducts - Variable external pressure - Wide range of accessories GFHE Drycoolers kw Additional information For data sheets and operating instructions go to Supports eacuation - The heat exchanger is inclined to support evacuation before freezing periods. - Operation with water without adding glycol provides further usage options in process engineering.
9 16 Güntner Competence Air Conditioning 17 Multifaceted requirements call for flexible solutions We have already solved many problems in our long-standing years of experience. You too should therefore take advantage of our experience! Requirements Topics such as sight screens, sound reduction, space shortage, building integration or systemspecific requirements end up on our desks every day. And we have a wide-ranging portfolio of solution options at our disposal for these very purposes! Costs philosophy - Low investment costs - Low operating costs - System service life - Will the system be extended at any time? - How important is operational reliability? Architecture and surroundings - Maximum set-up area - Sight screens - Construction - Sound specifications - Aggressive ambient air (proximity to sea, industrial area, etc.) Thermodynamics - Ambient temperature - Liquid temperatures - Pressure loss - Which liquid will be used? - What is the system s load profile? - Set-up site, e.g. Moscow, Mont Blanc, Madrid Cost-effective Consulting Optimum solution Güntner experience Cooler series GFD / GVD GFH / GVH GFW / GVW RFH / RVH GFHE Customising Connections Controls Corrosion protection Subcoolers Empty casing Multiple circuit coils Controls Special colours Liquid receivers Special customised construction
10 18 Güntner Competence Air Conditioning 19 Free cooling Free cooling is particularly beneficial with air conditioning systems, and especially for process cooling with all-year operation. Effectiveness: When the ambient temperature is lower than the return temperature from the consumer unit, the cooling medium is always routed via the drycooler and cooled by the ambient air. This relieves the chiller and decreases the output. Below a defined ambient temperature the drycooler assumes the complete cooling capacity and the chiller switches off. This system covers a large part of the annual operating hours with free cooling, and therefore significantly reduces energy consumption and saves on costs. Example: Air conditioning system for EDP (server rooms) Cold water temperature: C Operation: 24/ Hours per year 100 % free cooling Hamburg 200 Free cooling start 100 Drycooler Chiller Temperature ( C) C 15 C A typical area of application is cooling on EDP systems (servers) with moderate ambient temperatures. The diagram shows an example of the breakdown of operating hours between free cooling and the chiller. In areas with ambient temperatures below 0 C, a separate circuit with a water-glycol mix is required for the drycooler.
11 20 Güntner Competence Air Conditioning 21 Installation example for free cooling Direct cooling The entire system is filled with a water-glycol mixture. Indirect cooling Primary circuit with water for consumer unit Secondary circuit with water-glycol mixture for drycoolers/chillers - High efficiency (no plate heat exchanger) - Series connection for drycoolers and chillers for maximum free cooling use - Constant temperature control - Upgrade for existing systems possible - Filling the consumer unit side with water - Circuit separation with plate heat exchangers - Series connection of coolers for maximum free cooling use - Constant temperature control - Upgrade for existing systems possible Free cooler Liquid cooler Free cooler Liquid cooler Consumer unit Glycol Water Consumer unit
12 22 Güntner Competence Air Conditioning 23 Optimum coordinated regulation Güntner Controls has been delivering efficient and top quality controllers and switch cabinets, which are continuously further developed in accordance with the requirements of the refrigeration technology, for many years now. The units used are developed and produced in-house. They are therefore harmonized with the Güntner drycoolers and condensers and form a very important element of the intelligent Güntner heat exchanger systems. Why control? The condensation temperature in a compression refrigeration system should be as low as possible to minimize compressor operating costs, but high enough to guarantee the system s proper functioning at all times. Fan controlling is the most technically feasible method to achieve this objective. How to control? The basis for speed controlling is the recording of the current as-is values, such as pressure or temperature. The required control signals (RPMs) are calculated in the controller using the setpoint. Depending on the motor technology this setpoint is forwarded via the bus system to the fans directly or to a power. The bus system also enables constant communication with the fan or the power to be able to respond to incidents, such as operating information or faults, for example. The difference is made here between a constant and a stepped control principle. Güntner controllers are available for both control principles and have been specially developed for Güntner condensers and drycoolers, and are harmonized with AC or EC fan technology.
13 24 Güntner Competence Air Conditioning 25 Switch cabinets and control concepts The appropriate switch cabinets can be optionally ordered for every Güntner condenser and drycooler, with and without controllers. You have the option here of choosing between Güntner standard and customized switch cabinets. All switch cabinets are planned, designed, built and tested at Güntner s Controls division. Together with you, we subsequently produce and offer the appropriate switch cabinet and control concept. These switch cabinet concepts are then optimally adjusted to the set-up, output, energy efficiency and service life of the Güntner units. On-site and on request, switch cabinets are set up and wired directly to the unit. As an option we also offer you initial start-up operation by our specialist staff. Güntner GSS Switch Cabinet Innovative speed controllers Depending on the design, Güntner controllers are delivered with the extended functions of Güntner Motor Management (GMM). This provides the system builder with additional benefits: - BUS interface in superordinate systems, e.g. for integration into remote maintenance systems - Monitoring functions of important operation components - Operations and fault reports on the display - Bypass function to increase operational reliability - All-phase sine filter with the GMM sincon for maximising AC fan service life - Offset setpoint for maximising energy efficiency Controller technologies at a glance AC fans EC fans Control principle Stepped Stepped Stepped Constant Technology Step controller Phase cutting controller FC with sine filter EC technology Type GSTS GDRD GMM sincon GMM EC Low investment costs Precise control Noise-sensitive application Energy efficiency Low installation costs sehr gut weniger gut
14 26 Güntner Competence Air Conditioning 27 Save water Riyadh University system, Saudi Arabia Δt one way or the other, water is very scarce and expensive in some regions of the world. This is where air-cooled condensers and drycoolers are the only sensible alternative. This produces higher energy costs, but no consumption of desalinated seawater for evaporation cooling.
15 28 Güntner Competence Air Conditioning 29 Failure safety Thermodynamically precise constructions We run precise thermodynamic calculations to meet your requirements and select the right unit. We give you the optimum solution for your application specifications with reliable noise and power data. Don t just compare the price with offers you should also compare the technical data. Reliable Güntner units and equipment have various properties that make them especially fail-safe. - The Güntner floating coil design prevents the liquid-carrying tubes from touching the casing parts with thermal expansion. - The Güntner support profile braces the casing construction, reduces the number of base feet and protects the heat exchanger against torsion when being transported and installed. Safe solder connections The bushings for the collectors are produced at Güntner with a very special procedure. This involves a large area and safe solder connection with the contact tubes. Fans Güntner only uses leading manufacturer fans. Motor, fan blade, duct and protection grill form an optimum air and sound unit. The variable controlled external rotor motors are extremely long-life, maintenance-free and balanced on two levels. With series connected systems a high number of fans ensures failure-safe operation. On request, the fans are wired and fitted on-site with repair switches.
16 Quelle: ACCON GmbH 30 Güntner Competence Air Conditioning 31 Noise abatement The fans are available in different noise level classes. The sound specifications are confirmed by tests run by Eurovent. The installation point, including protection grill, fan ducts and heat exchangers, is measured here. Performance test, material combinations and special projects Measurement chambers in various sizes are at our disposal so we can measure all units. We also put together various detailed material combinations for the heat exchangers. We can run all required tests and material checks: Stability, strength, statics Usage limits Material compatibility We also provide you with special documentation on request: Calculation proof and documents in accordance with various standards and certificates, such as ASME, UL, CE, PED, GOST, EX Protection, for example.
17 32 Güntner Competence Air Conditioning 33 Easy transport and installation After production all Güntner units are packed appropriately for transport to the installation site. Once there they can be easily transported with a crane and forklift, because we have thought out the very smallest details: Crane lugs: The heat exchangers are equipped with factory mounted crane lugs. With the GFD units, we developed a special transport mechanism for crane transport that makes it possible to transport the unit without using a cross beam. Container: For container transport we produce units that fit precisely into a sea cargo container. Forklift The support profile and floating coil design make Güntner heat exchangers especially stable for transporting with forklifts.
18 34 Güntner Competence Air Conditioning 35 Set-up situations Building integration Different set-up situations require different unit designs. Certain minimum distances and set-up heights must be considered according to the site and combination of units. Narrow space conditions, sight screens and architecture requirements pose interesting challenges for the plant contractor We can also competently advise our customers in such cases. We have the respective experience, and will provide you with the necessary information for your planning. With complex measurement series we have created the basis for calculating your minimum distances and set-up heights. GVH / GFH Sight screens / design Free-standing set-up Multiple units set-up Building shaft Unit on a building wall Ludwig-Erhardt-Haus Berlin Out of view with angled drycooler Dockland Hamburg Sight screens, completely covered drycoolers with special dimensions Altmarktgalerie Dresden Monument conservation, sight screens, angled drycooler GVV / GFV Free-standing set-up Set-up in front of a wall Axel-Springer-Haus Berlin Penthouse made of grating Proton-Klinik München Special paint, to suit the architecture GFD / GVD GVW / GFW Tight areas Location 1&1 Karlsruhe Redundant system, units integrated into the building Wendelstein transmitter Stainless steel model, fan ring heater, thermodynamic configuration for 1,600 m above sea level. Riyadh University system, Saudi Arabia High capacities, high ambient temperatures
19 Errors excepted. Subject to technical amendments without prior notice. KAT / V1 / Güntner AG & Co. KG Hans-Güntner-Str Fürstenfeldbruck Germany
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
GPC. How do I call up the bid text for a selected unit? Why does the GPC calculate the surface reserve and not the capacity reserve?
GPC Important tips and tricks for the Güntner Product Calculator How do I call up the bid text for a selected unit? Why does the GPC calculate the surface reserve and not the capacity reserve? Where can
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
State of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction
your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction What is DNSS EcoSave? The Daikin Network Service System (DNSS EcoSave) is a Daikin developed internet based remote
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems
Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
Nordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
Refrigeration and air-conditioning. Alfa Laval s offering at a glance
Refrigeration and air-conditioning Alfa Laval s offering at a glance At Alfa Laval green is cool Alfa Laval products are also installed on oil platforms, in power plants, onboard ships, in the mechanical
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling. 100 4,000 kw
INFO HTK Hybrid dry cooler The reference for hybrid dry cooling 4, kw JAEGGI The Original Since 929, JAEGGI has been engaged in the development, production and sale of heat exchangers. Since 995, the company
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
The Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
Commercial Refrigeration
Güntner Competence Commercial Refrigeration Food processing Fast cooling and freezing Storage of unpacked, sensitive goods Storage of packed goods Cold storage room Heat dissipation 2 Güntner Competence
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
Statement of Work. 3.0 Details of Service Pre Start-up. - 1 - Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary
Installation Service Statement of Work - 1 - Cooling Start-up Service Cooling Start-up Service Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details
COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers
COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A
COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A (All unshaded skill sets must be demonstrated/completed) PROTECT SELF AND OTHERS Identify, interpret, and
Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA
Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale
AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM
DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next
JAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
Chilled Water Precision Air Conditioner For Critical Application
AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),
Coldrooms designed for your application
UK Price Book 2013 Coldrooms Coldrooms designed for your application Foster Coldstores has a wealth of experience in the manufacture and supply of coldrooms. We can satisfy all business needs ranging from
Generators TEM. for small hydroelectric power stations. Electric Machines
Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric
marine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM
DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next
ROTEX gas hybrid heat pump. A strong team.
ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Leading-edge technology for machine tools
Leading-edge technology for machine tools We combine five specialists in one Improving productivity and successfully distinguishing themselves from the competition are key objectives for machine tool
IV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE
Modular Data Center Cooling Ultra High Efficiency Oasis Optimum DCIE Oasis Optimum Modular Cooling Compact, Economic, Greener, Ultra High Efficiency Munters Oasis Optimum DCIE data center cooling solution
Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity
Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry
Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems
Miracel 19 rack platform for data center, telecommunication and network technology Rack & Integrated Enclosure Systems The Miracel innovation rack multi-talented, distinguished, integrative The Miracel
SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING
SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING HOFFMAN SPECTRACOOL INDOOR/OUTDOOR AIR CONDITIONERS ENERGY-EFFICIENT, FILTERLESS AIR CONDITIONERS NOW AVAILABLE WITH
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
ABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
Top Technology for Industry, Agriculture, Business and Communities
Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,
Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice
Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice A truly international certification The Eurovent Certification Programmes are managed by an autonomous
Air-water systems for efficient air conditioning
Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Drives and motors. A guide to using variable-speed drives and motors in data centres
Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers
Alfa Laval Abatigo. Redefining adiabatic cooling
Alfa Laval Abatigo Redefining adiabatic cooling Experience and expertise recognized throughout the world With decades of broad experience and practical expertise in heat transfer, Alfa Laval is today a
AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES
AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA GLOBAL DATA CENTRE IP TRAFFIC WILL TRIPLE WITHIN 5 YEARS Global data centre IP traffic has set a constant growth path, with
Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages
Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some
Building Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
Small-Scale Solar Heating and Cooling Systems
Contact Austria: AEE INTEC (www.aee-intec.at) France: Tecsol (www.tecsol.fr) Germany: Fraunhofer ISE (www.ise.fraunhofer.de) Greece: CRES (www.cres.gr) Italy: EURAC (www.eurac.edu) University of Bergamo
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
-Liquid-cooled frequency converter switchgear
-Liquid-cooled frequency converter switchgear VEO knows your needs We deliver automation and electrification solutions for energy production, distribution and consumption in close collaboration with our
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
Passive Cooling Systems Air Conditioning Without the Need of Energy
Passive Cooling Systems Air Conditioning Without the Need of Energy 1 Introduction and Abstract PCS Shelter for ADCO SAS project in the UAE/Sahil and Shah Pipe Lines and Supply Networks often run through
Turbo generators Best quality for thermal power plants
Turbo generators Best quality for thermal power plants www.andritz.com ANDRITZ HYDRO Turbo generators International technology Group ANDRITZ is a globally leading supplier of plants, equipment, and services
AIR CONDITIONING TECHNOLOGY
AIR CONDITIONING TECHNOLOGY PART 9 Water Cooled Condensers & Cooling Towers IN LAST month s article we looked at how Air Cooled Condensers are used to transfer the total heat of rejection from the air
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
FVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
Cool air. Air heat-exchanger solutions from Alfa Laval.
Cool air. Air heat-exchanger solutions from Alfa Laval. Air. The perfect way to cool anything anywhere. If your business is to keep things perfectly cool whether it s food in a supermarket, people in a
Cool Design for Homes and Offices
AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners
The natural ombination
The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR
3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER
MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau
Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments Weiss Klimatechnik GmbH Geräte- und Anlagenbau in use throughout the world Al-Batnan Medical Center, Tobruk System solutions for
RiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
Are these noise cancelling devices needed to make your chiller quiet??
Are these noise cancelling devices needed to make your chiller quiet?? Not on this chiller! Some sound barriers should never be broken. Government authorities recommend that exposure to loud noise over
Advances in Gas Cooler Design and the New Gas Cooler Product Selector
Advances in Gas Cooler Design and the New Gas Cooler Product Selector Simon Jones Engineering Manager Sean Armitage Sales Manager Introduction GEA Searle Over 90 years experience in the design and manufacture
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Nirvana. Cycling Refrigerated Dryers
Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:
Butterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40