Güntner Competence. Air Conditioning. Hotel. City Mall EDP. University

Size: px
Start display at page:

Download "Güntner Competence. Air Conditioning. Hotel. City Mall EDP. University"

Transcription

1 Güntner Competence Air Conditioning EDP Hotel City Mall Bank Production University

2 2 Güntner Competence Air Conditioning 3 Güntner offers its customers a wide range of condensers and drycoolers. This product range and individual selection via Güntner s GPC software produce diverse solution options for every customer requirement. Heinz Jackmann, Head of Product Management The requirement for air conditioning has increased sharply over the past two decades. A service provider society with numerous administration centres has emerged in Central Europe in particular. First and foremost, insurance companies, banks, telecommunication companies and Internet operators have developed very fast. A similar service provider society will also emerge in other countries. Güntner, among others, has shaped this market as the leading manufacturer of condensers and drycoolers. Güntner products can be individually configured and produced for every area of application. This ensures the ideal drycooler for your requirements. Our Technical Sales supports you with comprehensive consulting on the phone or personally on-site. Competent. Reliable. Personal.

3 4 Güntner Competence Air Conditioning 5 Achieving objectives together with partnership-based consulting Individual project situation Decision on requests/planning Quote Sales strategy Product strategy Take advantage of Güntner s extensive experience. With specific application know-how and innovative products we can work out optimum solutions together with you. We project the heat exchangers according to your specifications with reliable data and advise you on the best possible selection, equipping and number of units. Our technical sales staff support you in your search for the optimum concept, and also provides you with the required technical data for your planning.

4 6 Güntner Competence Air Conditioning 7 Quickly and safe Calculate thermodynamically & prepare offers The Güntner Product Calculator GPC configuration software allows you to quickly and easily configure the right unit for your individual application. Simply enter the required basic data in the convenient entry screen on the GPC. An exact thermodynamic configuration is performed and a selection of the suitable units is provided while considering your selected operating conditions and selected accessories. You consequently choose the optimum unit and the GPC generates a data sheet with technical data, dimensions, weights and prices for you. Download your free Güntner Product Calculator (GPC) at: Use our GPC for selecting evaporators, condensers, air coolers, drycoolers, control units and switch cabinets! Possible input data: Brine exit temperature Air temperature Accessories Output Brine entry temperature Thermodynamic calculation = optimum unit selection for every application case Liquid recirculation Subcooling temperature Sound pressure level Medium

5 8 Güntner Competence Air Conditioning 9 Large orders for different markets Westfield White City Shopping Centre, London Güntner drycoolers Güntner has 6 production sites on 3 continents, and can therefore meet local requirements and regulations, and guarantee you short delivery times and cost-efficient transporting on all markets. Our production sites are strategically located and have the appropriate capacity to supply you on schedule with high volume orders. Güntner has completed numerous large-scale projects around the globe over the past few decades.

6 10 Güntner Competence Air Conditioning 11 Global presence As your partner we support you around the entire globe! You will find us at over 50 locations in almost every important production and trade centre in Europe, the Americas and Asia. We speak the language of the market and understand regional laws and mentalities. Production site, Russia Head Office, Germany Production site, Hungary Production site, Mexico Production site, Indonesia Production sites Local offices Distribution area Production site, Brazil A global community of experts

7 12 Güntner Competence Air Conditioning 13 High demand reliable products Güntner only uses the high-grade materials of certified manufacturers in producing its heat exchangers. These are processed on modern machinery into high-quality and optically appealing products. In addition to cost-effectiveness, safety of staff and environmental protection are also high priority Güntner corporate goals. Quality claim The Güntner quality claim covers all work steps from planning to development, right through to production. Tests Güntner heat exchangers are continuously tested and certified by independent institutions: Supplier management The selection of qualified suppliers is a decisive criterion for Güntner in producing its top quality products. Only the tested products of certified manufacturers are used. Quality management Comprehensive quality management is applied at all our production sites. We consequently guarantee that the production process and the end products are continuously checked. DIN ISO 9001 GOST UL CE Eurovent VDE TÜV HACCP

8 14 Güntner Competence Air Conditioning 15 Series GFD / GVD V-coil drycoolers / V-coil condensers kw GFH / GFV Horizontal / vertical drycoolers kw Big capacity with small set-up area - V-shape heat exchanger set-up - Maximum number of fans per unit Classic, robust structure, proven for decades - Design for horizontal and vertical set-up - High power and sound spectrum - Suitable for all applications GFW / GVW Drycoolers / condensers kw RFH / RVH Drycoolers / condensers kw High power density, low installation height - With larger systems several devices can be space-savingly linked together on one steel frame. With radial fans for indoor set-up - For indoor set-up and connection to air ducts - Variable external pressure - Wide range of accessories GFHE Drycoolers kw Additional information For data sheets and operating instructions go to Supports eacuation - The heat exchanger is inclined to support evacuation before freezing periods. - Operation with water without adding glycol provides further usage options in process engineering.

9 16 Güntner Competence Air Conditioning 17 Multifaceted requirements call for flexible solutions We have already solved many problems in our long-standing years of experience. You too should therefore take advantage of our experience! Requirements Topics such as sight screens, sound reduction, space shortage, building integration or systemspecific requirements end up on our desks every day. And we have a wide-ranging portfolio of solution options at our disposal for these very purposes! Costs philosophy - Low investment costs - Low operating costs - System service life - Will the system be extended at any time? - How important is operational reliability? Architecture and surroundings - Maximum set-up area - Sight screens - Construction - Sound specifications - Aggressive ambient air (proximity to sea, industrial area, etc.) Thermodynamics - Ambient temperature - Liquid temperatures - Pressure loss - Which liquid will be used? - What is the system s load profile? - Set-up site, e.g. Moscow, Mont Blanc, Madrid Cost-effective Consulting Optimum solution Güntner experience Cooler series GFD / GVD GFH / GVH GFW / GVW RFH / RVH GFHE Customising Connections Controls Corrosion protection Subcoolers Empty casing Multiple circuit coils Controls Special colours Liquid receivers Special customised construction

10 18 Güntner Competence Air Conditioning 19 Free cooling Free cooling is particularly beneficial with air conditioning systems, and especially for process cooling with all-year operation. Effectiveness: When the ambient temperature is lower than the return temperature from the consumer unit, the cooling medium is always routed via the drycooler and cooled by the ambient air. This relieves the chiller and decreases the output. Below a defined ambient temperature the drycooler assumes the complete cooling capacity and the chiller switches off. This system covers a large part of the annual operating hours with free cooling, and therefore significantly reduces energy consumption and saves on costs. Example: Air conditioning system for EDP (server rooms) Cold water temperature: C Operation: 24/ Hours per year 100 % free cooling Hamburg 200 Free cooling start 100 Drycooler Chiller Temperature ( C) C 15 C A typical area of application is cooling on EDP systems (servers) with moderate ambient temperatures. The diagram shows an example of the breakdown of operating hours between free cooling and the chiller. In areas with ambient temperatures below 0 C, a separate circuit with a water-glycol mix is required for the drycooler.

11 20 Güntner Competence Air Conditioning 21 Installation example for free cooling Direct cooling The entire system is filled with a water-glycol mixture. Indirect cooling Primary circuit with water for consumer unit Secondary circuit with water-glycol mixture for drycoolers/chillers - High efficiency (no plate heat exchanger) - Series connection for drycoolers and chillers for maximum free cooling use - Constant temperature control - Upgrade for existing systems possible - Filling the consumer unit side with water - Circuit separation with plate heat exchangers - Series connection of coolers for maximum free cooling use - Constant temperature control - Upgrade for existing systems possible Free cooler Liquid cooler Free cooler Liquid cooler Consumer unit Glycol Water Consumer unit

12 22 Güntner Competence Air Conditioning 23 Optimum coordinated regulation Güntner Controls has been delivering efficient and top quality controllers and switch cabinets, which are continuously further developed in accordance with the requirements of the refrigeration technology, for many years now. The units used are developed and produced in-house. They are therefore harmonized with the Güntner drycoolers and condensers and form a very important element of the intelligent Güntner heat exchanger systems. Why control? The condensation temperature in a compression refrigeration system should be as low as possible to minimize compressor operating costs, but high enough to guarantee the system s proper functioning at all times. Fan controlling is the most technically feasible method to achieve this objective. How to control? The basis for speed controlling is the recording of the current as-is values, such as pressure or temperature. The required control signals (RPMs) are calculated in the controller using the setpoint. Depending on the motor technology this setpoint is forwarded via the bus system to the fans directly or to a power. The bus system also enables constant communication with the fan or the power to be able to respond to incidents, such as operating information or faults, for example. The difference is made here between a constant and a stepped control principle. Güntner controllers are available for both control principles and have been specially developed for Güntner condensers and drycoolers, and are harmonized with AC or EC fan technology.

13 24 Güntner Competence Air Conditioning 25 Switch cabinets and control concepts The appropriate switch cabinets can be optionally ordered for every Güntner condenser and drycooler, with and without controllers. You have the option here of choosing between Güntner standard and customized switch cabinets. All switch cabinets are planned, designed, built and tested at Güntner s Controls division. Together with you, we subsequently produce and offer the appropriate switch cabinet and control concept. These switch cabinet concepts are then optimally adjusted to the set-up, output, energy efficiency and service life of the Güntner units. On-site and on request, switch cabinets are set up and wired directly to the unit. As an option we also offer you initial start-up operation by our specialist staff. Güntner GSS Switch Cabinet Innovative speed controllers Depending on the design, Güntner controllers are delivered with the extended functions of Güntner Motor Management (GMM). This provides the system builder with additional benefits: - BUS interface in superordinate systems, e.g. for integration into remote maintenance systems - Monitoring functions of important operation components - Operations and fault reports on the display - Bypass function to increase operational reliability - All-phase sine filter with the GMM sincon for maximising AC fan service life - Offset setpoint for maximising energy efficiency Controller technologies at a glance AC fans EC fans Control principle Stepped Stepped Stepped Constant Technology Step controller Phase cutting controller FC with sine filter EC technology Type GSTS GDRD GMM sincon GMM EC Low investment costs Precise control Noise-sensitive application Energy efficiency Low installation costs sehr gut weniger gut

14 26 Güntner Competence Air Conditioning 27 Save water Riyadh University system, Saudi Arabia Δt one way or the other, water is very scarce and expensive in some regions of the world. This is where air-cooled condensers and drycoolers are the only sensible alternative. This produces higher energy costs, but no consumption of desalinated seawater for evaporation cooling.

15 28 Güntner Competence Air Conditioning 29 Failure safety Thermodynamically precise constructions We run precise thermodynamic calculations to meet your requirements and select the right unit. We give you the optimum solution for your application specifications with reliable noise and power data. Don t just compare the price with offers you should also compare the technical data. Reliable Güntner units and equipment have various properties that make them especially fail-safe. - The Güntner floating coil design prevents the liquid-carrying tubes from touching the casing parts with thermal expansion. - The Güntner support profile braces the casing construction, reduces the number of base feet and protects the heat exchanger against torsion when being transported and installed. Safe solder connections The bushings for the collectors are produced at Güntner with a very special procedure. This involves a large area and safe solder connection with the contact tubes. Fans Güntner only uses leading manufacturer fans. Motor, fan blade, duct and protection grill form an optimum air and sound unit. The variable controlled external rotor motors are extremely long-life, maintenance-free and balanced on two levels. With series connected systems a high number of fans ensures failure-safe operation. On request, the fans are wired and fitted on-site with repair switches.

16 Quelle: ACCON GmbH 30 Güntner Competence Air Conditioning 31 Noise abatement The fans are available in different noise level classes. The sound specifications are confirmed by tests run by Eurovent. The installation point, including protection grill, fan ducts and heat exchangers, is measured here. Performance test, material combinations and special projects Measurement chambers in various sizes are at our disposal so we can measure all units. We also put together various detailed material combinations for the heat exchangers. We can run all required tests and material checks: Stability, strength, statics Usage limits Material compatibility We also provide you with special documentation on request: Calculation proof and documents in accordance with various standards and certificates, such as ASME, UL, CE, PED, GOST, EX Protection, for example.

17 32 Güntner Competence Air Conditioning 33 Easy transport and installation After production all Güntner units are packed appropriately for transport to the installation site. Once there they can be easily transported with a crane and forklift, because we have thought out the very smallest details: Crane lugs: The heat exchangers are equipped with factory mounted crane lugs. With the GFD units, we developed a special transport mechanism for crane transport that makes it possible to transport the unit without using a cross beam. Container: For container transport we produce units that fit precisely into a sea cargo container. Forklift The support profile and floating coil design make Güntner heat exchangers especially stable for transporting with forklifts.

18 34 Güntner Competence Air Conditioning 35 Set-up situations Building integration Different set-up situations require different unit designs. Certain minimum distances and set-up heights must be considered according to the site and combination of units. Narrow space conditions, sight screens and architecture requirements pose interesting challenges for the plant contractor We can also competently advise our customers in such cases. We have the respective experience, and will provide you with the necessary information for your planning. With complex measurement series we have created the basis for calculating your minimum distances and set-up heights. GVH / GFH Sight screens / design Free-standing set-up Multiple units set-up Building shaft Unit on a building wall Ludwig-Erhardt-Haus Berlin Out of view with angled drycooler Dockland Hamburg Sight screens, completely covered drycoolers with special dimensions Altmarktgalerie Dresden Monument conservation, sight screens, angled drycooler GVV / GFV Free-standing set-up Set-up in front of a wall Axel-Springer-Haus Berlin Penthouse made of grating Proton-Klinik München Special paint, to suit the architecture GFD / GVD GVW / GFW Tight areas Location 1&1 Karlsruhe Redundant system, units integrated into the building Wendelstein transmitter Stainless steel model, fan ring heater, thermodynamic configuration for 1,600 m above sea level. Riyadh University system, Saudi Arabia High capacities, high ambient temperatures

19 Errors excepted. Subject to technical amendments without prior notice. KAT / V1 / Güntner AG & Co. KG Hans-Güntner-Str Fürstenfeldbruck Germany

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

GPC. How do I call up the bid text for a selected unit? Why does the GPC calculate the surface reserve and not the capacity reserve?

GPC. How do I call up the bid text for a selected unit? Why does the GPC calculate the surface reserve and not the capacity reserve? GPC Important tips and tricks for the Güntner Product Calculator How do I call up the bid text for a selected unit? Why does the GPC calculate the surface reserve and not the capacity reserve? Where can

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

State of the Art Energy Efficient Data Centre Air Conditioning

State of the Art Energy Efficient Data Centre Air Conditioning - White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...

More information

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction What is DNSS EcoSave? The Daikin Network Service System (DNSS EcoSave) is a Daikin developed internet based remote

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems Knürr CoolAdd The universal retrofit solution against overheating in server racks Rack & Enclosure Systems Knürr CoolAdd When cold air is no longer enough! Data centers are subject to constant changes:

More information

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75

Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER

More information

Nordic Heat Pump Product Guide

Nordic Heat Pump Product Guide Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -

AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW - AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness

More information

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Refrigeration and air-conditioning. Alfa Laval s offering at a glance Refrigeration and air-conditioning Alfa Laval s offering at a glance At Alfa Laval green is cool Alfa Laval products are also installed on oil platforms, in power plants, onboard ships, in the mechanical

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling. 100 4,000 kw

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling. 100 4,000 kw INFO HTK Hybrid dry cooler The reference for hybrid dry cooling 4, kw JAEGGI The Original Since 929, JAEGGI has been engaged in the development, production and sale of heat exchangers. Since 995, the company

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

The Different Types of Air Conditioning Equipment for IT Environments

The Different Types of Air Conditioning Equipment for IT Environments The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.

More information

Commercial Refrigeration

Commercial Refrigeration Güntner Competence Commercial Refrigeration Food processing Fast cooling and freezing Storage of unpacked, sensitive goods Storage of packed goods Cold storage room Heat dissipation 2 Güntner Competence

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

News in Data Center Cooling

News in Data Center Cooling News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase

More information

Statement of Work. 3.0 Details of Service Pre Start-up. - 1 - Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

Statement of Work. 3.0 Details of Service Pre Start-up. - 1 - Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary Installation Service Statement of Work - 1 - Cooling Start-up Service Cooling Start-up Service Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details

More information

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers COMMERCIAL HVAC CHILLER EQUIPMENT Air-Cooled Chillers Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A (All unshaded skill sets must be demonstrated/completed) PROTECT SELF AND OTHERS Identify, interpret, and

More information

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale

More information

AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next

More information

JAWAHARLAL NEHRU UNIVERSITY

JAWAHARLAL NEHRU UNIVERSITY School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational

More information

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction

More information

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List

More information

Chilled Water Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner For Critical Application AIRSYS-P-SC-OPTIMA-HD-E1304V01.2 HD Chilled Water Precision Air Conditioner For Critical Application Cooling capacity: 42.1kW~161.5kW OPTIMA product family is designed for medium to large data center.

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),

More information

Coldrooms designed for your application

Coldrooms designed for your application UK Price Book 2013 Coldrooms Coldrooms designed for your application Foster Coldstores has a wealth of experience in the manufacture and supply of coldrooms. We can satisfy all business needs ranging from

More information

Generators TEM. for small hydroelectric power stations. Electric Machines

Generators TEM. for small hydroelectric power stations. Electric Machines Generators for small hydroelectric power stations TEM Electric Machines Advanced solutions for the cleanest energy Reputable manufacturer of generators for small hydroelectric power stations TED Electric

More information

marine/bespoke split applications

marine/bespoke split applications split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

CoolTeg Plus Chilled Water (CW) version: AC-TCW

CoolTeg Plus Chilled Water (CW) version: AC-TCW version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM

IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next

More information

ROTEX gas hybrid heat pump. A strong team.

ROTEX gas hybrid heat pump. A strong team. ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat

More information

SECTION 23 81 43 HEAT PUMPS

SECTION 23 81 43 HEAT PUMPS SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Leading-edge technology for machine tools

Leading-edge technology for machine tools Leading-edge technology for machine tools We combine five specialists in one Improving productivity and successfully distinguishing themselves from the competition are key objectives for machine tool

More information

IV. Rear Mount System

IV. Rear Mount System Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading

More information

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems

More information

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE Modular Data Center Cooling Ultra High Efficiency Oasis Optimum DCIE Oasis Optimum Modular Cooling Compact, Economic, Greener, Ultra High Efficiency Munters Oasis Optimum DCIE data center cooling solution

More information

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry

More information

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems

Miracel 19 rack platform for data center, telecommunication and network technology. Rack & Integrated Enclosure Systems Miracel 19 rack platform for data center, telecommunication and network technology Rack & Integrated Enclosure Systems The Miracel innovation rack multi-talented, distinguished, integrative The Miracel

More information

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING HOFFMAN SPECTRACOOL INDOOR/OUTDOOR AIR CONDITIONERS ENERGY-EFFICIENT, FILTERLESS AIR CONDITIONERS NOW AVAILABLE WITH

More information

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed

Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires

More information

ABB central inverters PVS800 100 to 1000 kw

ABB central inverters PVS800 100 to 1000 kw Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and

More information

Top Technology for Industry, Agriculture, Business and Communities

Top Technology for Industry, Agriculture, Business and Communities Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion

More information

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water 2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation

More information

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,

More information

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice

Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice Eurovent Certification for Air Handling Units : Five Energy Efficiency classes to make the right choice A truly international certification The Eurovent Certification Programmes are managed by an autonomous

More information

Air-water systems for efficient air conditioning

Air-water systems for efficient air conditioning Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Drives and motors. A guide to using variable-speed drives and motors in data centres

Drives and motors. A guide to using variable-speed drives and motors in data centres Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers

More information

Alfa Laval Abatigo. Redefining adiabatic cooling

Alfa Laval Abatigo. Redefining adiabatic cooling Alfa Laval Abatigo Redefining adiabatic cooling Experience and expertise recognized throughout the world With decades of broad experience and practical expertise in heat transfer, Alfa Laval is today a

More information

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES

AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA CENTRES AERMEC DATA CENTRE SOLUTIONS THE COMPLETE RANGE OF AERMEC SOLUTIONS FOR DATA GLOBAL DATA CENTRE IP TRAFFIC WILL TRIPLE WITHIN 5 YEARS Global data centre IP traffic has set a constant growth path, with

More information

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some

More information

Building Energy Systems. - HVAC: Heating, Distribution -

Building Energy Systems. - HVAC: Heating, Distribution - * Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center

More information

Small-Scale Solar Heating and Cooling Systems

Small-Scale Solar Heating and Cooling Systems Contact Austria: AEE INTEC (www.aee-intec.at) France: Tecsol (www.tecsol.fr) Germany: Fraunhofer ISE (www.ise.fraunhofer.de) Greece: CRES (www.cres.gr) Italy: EURAC (www.eurac.edu) University of Bergamo

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

-Liquid-cooled frequency converter switchgear

-Liquid-cooled frequency converter switchgear -Liquid-cooled frequency converter switchgear VEO knows your needs We deliver automation and electrification solutions for energy production, distribution and consumption in close collaboration with our

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

Passive Cooling Systems Air Conditioning Without the Need of Energy

Passive Cooling Systems Air Conditioning Without the Need of Energy Passive Cooling Systems Air Conditioning Without the Need of Energy 1 Introduction and Abstract PCS Shelter for ADCO SAS project in the UAE/Sahil and Shah Pipe Lines and Supply Networks often run through

More information

Turbo generators Best quality for thermal power plants

Turbo generators Best quality for thermal power plants Turbo generators Best quality for thermal power plants www.andritz.com ANDRITZ HYDRO Turbo generators International technology Group ANDRITZ is a globally leading supplier of plants, equipment, and services

More information

AIR CONDITIONING TECHNOLOGY

AIR CONDITIONING TECHNOLOGY AIR CONDITIONING TECHNOLOGY PART 9 Water Cooled Condensers & Cooling Towers IN LAST month s article we looked at how Air Cooled Condensers are used to transfer the total heat of rejection from the air

More information

Daikin Altherma hybrid heat pump. The natural combination

Daikin Altherma hybrid heat pump. The natural combination Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient

More information

FVA/A1 saturated-steam sterilizer

FVA/A1 saturated-steam sterilizer FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly

More information

Cool air. Air heat-exchanger solutions from Alfa Laval.

Cool air. Air heat-exchanger solutions from Alfa Laval. Cool air. Air heat-exchanger solutions from Alfa Laval. Air. The perfect way to cool anything anywhere. If your business is to keep things perfectly cool whether it s food in a supermarket, people in a

More information

Cool Design for Homes and Offices

Cool Design for Homes and Offices AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners

More information

The natural ombination

The natural ombination The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR 3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER

More information

MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau

MEDICLEAN. Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments. Weiss Klimatechnik GmbH Geräte- und Anlagenbau Perfect Hygiene Air-Conditioning Solutions for all Hospital Departments Weiss Klimatechnik GmbH Geräte- und Anlagenbau in use throughout the world Al-Batnan Medical Center, Tobruk System solutions for

More information

RiMatrix S Make easy.

RiMatrix S Make easy. RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power

More information

Are these noise cancelling devices needed to make your chiller quiet??

Are these noise cancelling devices needed to make your chiller quiet?? Are these noise cancelling devices needed to make your chiller quiet?? Not on this chiller! Some sound barriers should never be broken. Government authorities recommend that exposure to loud noise over

More information

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

Advances in Gas Cooler Design and the New Gas Cooler Product Selector Advances in Gas Cooler Design and the New Gas Cooler Product Selector Simon Jones Engineering Manager Sean Armitage Sales Manager Introduction GEA Searle Over 90 years experience in the design and manufacture

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information