GRUNDFOS DATA BOOKLET. Sanitary pumps. Centrifugal pumps 50 Hz
|
|
|
- Loren Charles
- 10 years ago
- Views:
Transcription
1 GRUNDFOS DATA BOOKLET Sanitary pumps Centrifugal pumps 5 Hz
2 Contents Introduction Grundfos sanitary pumps Hygienic design Performance range Performance range, -pole 5 Performance range, -pole 5 Euro-HYGIA Euro-HYGIA 6 F&B-HYGIA F&B-HYGIA 8 Contra Contra 1 durietta durietta 1 SIPLA SIPLA 1 MAXA and MAXANA MAXA and MAXANA 16 Identification Type keys 18 Product range Sanitary pumps 19 Design variations Version key 3 Motor ranges Motor protection 7 Connection selection guide Selection of connection according to application 8 Selection of connection according to pump type 9 Design 3 Pipe connections Euro-HYGIA 3 F&B-HYGIA 36 Contra I 37 Contra II durietta 3 durietta, continued 5 SIPLA 6 MAXA 7 MAXANA 9 Construction Pumps 51 Impellers 51 Surface treatment 5 Motors 5 Shaft seals Mechanical shaft seal 53 Certification EHEDG, QHD and GOST 55 Certificates and approvals 55 Surface finish of sanitary pumps 56 Installation Mechanical installation 57 Space requirements 57 Elimination of noise and vibration 58 Terminal box positions 58 Curve charts How to read the curve charts 59 Curve conditions 6 Performance curves/technical data Euro-HYGIA I 61 Euro-HYGIA I 61 Euro-HYGIA I Adapta on cast iron foot 6 Euro-HYGIA I Adapta SUPER on stainless steel combi foot (frame size 8-9) 63 Euro-HYGIA I Adapta SUPER on stainless steel combi foot (frame size 1-13) 6 Euro-HYGIA I Bloc on cast iron foot 65 Euro-HYGIA II 67 Euro-HYGIA II 67 Euro-HYGIA II Adapta on Adapta foot (frame size 18M) 68 Euro-HYGIA II Adapta on cast iron foot (frame size 1-16) 69
3 Contents Euro-HYGIA II Adapta SUPER on stainless steel combi foot (frame size 1-16) 7 Euro-HYGIA II Adapta SUPER on machine feet (frame size 18) 71 Euro-HYGIA II Bloc on cast iron foot (frame size 9-13) 7 Euro-HYGIA II Bloc on motor foot with stainless steel support (frame size 16) 73 Euro-HYGIA II Bloc-SUPER on stainless steel combi foot (frame size 9-13) 7 Euro-HYGIA II Bloc-SUPER on stainless steel combi foot (frame size 16) 75 F&B-HYGIA I 76 F&B-HYGIA I K on motor foot 77 F&B-HYGIA I K on cast iron foot 78 F&B-HYGIA I K SUPER on combi foot 8 F&B-HYGIA II 81 F&B-HYGIA II K on motor foot 8 F&B-HYGIA II K on combi foot (frame size 16) 85 F&B-HYGIA II K SUPER on combi foot (frame size 1-13) 86 F&B-HYGIA II K SUPER on combi foot (frame size 16) 87 Contra I 88 Contra I Adapta on cast iron foot 89 Contra I Adapta SUPER on stainless steel combi foot (frame size 1-13) 91 Contra I Adapta -V on stainless steel pedestal with/without suction elbow 9 Contra I Bloc on cast iron foot 93 Contra I Bloc-SUPER on stainless steel combi foot 9 Contra II 95 Contra II Adapta on cast iron foot 96 Contra II Adapta SUPER on stainless steel combi foot (frame size 1-16) 97 Contra II Adapta -V on stainless steel pedestal with/without suction elbow (frame size 1-16) 98 Contra II Bloc on cast iron foot (frame size 9-13) 99 Contra II Bloc-SUPER on stainless steel combi foot (frame size 9-13) 1 durietta 1 durietta 1 durietta K on motor foot 13 SIPLA 15 SIPLA 15 SIPLA 16 SIPLA Adapta on cast iron foot 17 SIPLA Adapta SUPER on combi foot 19 SIPLA Bloc on motor foot 11 SIPLA Bloc-SUPER on stainless steel ball feet 111 MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA MAXA 15-1 MAXA - 1 MAXA L 11 MAXA CN 13 MAXANA MAXANA MAXANA 3-17 MAXANA MAXANA - 19 MAXANA MAXANA MAXANA 5-13 MAXANA 5-13 MAXANA MAXANA MAXANA MAXANA MAXANA MAXANA Adapta on stainless steel foot 137 MAXANA Adapta on Adapta foot 138 MAXANA Bloc on pump and motor foot 139 MAXANA Bloc on motor foot 11 Further product documentation WebCAPS 1 3
4 Introduction Sanitary pumps Grundfos sanitary pumps Grundfos stainless steel sanitary pumps are designed for a wide range of hygienic and sanitary fields of application such as: food and beverage industry life science/pharmaceutical industry personal care water treatment. The Grundfos range of sanitary pumps comprises the below pump types, each state-of-the-art within their specific field of application. The pumps can be fitted with a variety of features to adapt to specific pumping tasks. In addition, it is possible to customise the pumps for optimum function or performance in relation to the job at hand. Euro-HYGIA Euro-HYGIA single-stage, end-suction centrifugal pumps come in a variety of flexible versions. The pumps offer heads up to 7 metres, flow rates up to 5 m 3 /h and operating pressures up to 16 bar. Pipe connections range from DN 5 to DN 15 and motor sizes from.55 to kw. See page 6. F&B-HYGIA F&B-HYGIA single-stage, end-suction centrifugal pumps offer heads up to 7 metres, flow rates up to 15 m 3 /h and operating pressures up to 16 bar. Pipe connections range from DN to DN 1 and motor sizes from 1.1 to 18.5 kw. See page 8. Contra Contra single-stage or multi-stage, end-suction centrifugal pumps come in a variety of flexible versions. The pumps offer heads up to 16 metres, flow rates up to 55 m 3 /h and operating pressures up to 5 bar. Pipe connections range from DN 5 to DN 8 and motor sizes from.55 to 18.5 kw. See page 1. durietta durietta single-stage or multi-stage centrifugal pumps offer low flow and high head. The pumps are available in a vertical and a horizontal version. The pumps offer heads up to 7 metres, flow rates up to 6 m 3 /h and operating pressures up to 8 bar. Pipe connections range from DN 5 to DN and motor sizes from.5 to. kw. See page 1. SIPLA SIPLA single-stage, self-priming, side-channel pumps offer heads up to 56 metres, flow rates up to 8 m 3 /h and operating pressures up to 1 bar. Pipe connections range from DN 3 to DN 8 and motor sizes from.75 to kw. See page 1. MAXA and MAXANA MAXA and MAXANA are single-stage, end-suction centrifugal pumps. The MAXA pumps are designed according to DIN EN 733. The pumps offer heads up to 97 metres, flow rates up to 8 m 3 /h and operating pressures up to 1 bar. Pipe connections range from DN 3 to DN 15 and motor sizes from.55 to 9 kw. See page 16. Hygienic design The Grundfos sanitary pumps have been designed in accordance with the strictest hygienic design criteria. The surface finish of the materials used is of paramount importance to prevent possible breeding grounds for bacteria and germs. Fully drainable models are available, and the use of AISI 316L (DIN EN 1./1.35) cold-rolled and/or forged stainless steel ensures a homogeneous, pore-free surface in contrast to cast materials. The design, materials and material surface finish are subject to a variety of national and international rules and regulations, guidelines and laws. Among these are the EU Machinery Directive, the GMP (Good Manufacturing Practices) rules and regulations, the FDA (Food and Drug Administration) regulations, the EU foodstuff hygienic guidelines, the DIN EN 16 Biotechnology Standard as well as the EHEDG (European Hygienic Engineering & Design Group) and the QHD (Qualified Hygienic Design) criteria. Shaft seals Single, flushed or double mechanical shaft seal arrangements are available, depending on the application and the pumped liquid. The seals offer trouble-free operation. The single shaft seals are inboard mechanical seals with the optimum position in the pumped liquid in order to ensure lubrication, cooling as well as CIP (Cleaning-In- Place) and SIP (Sterilisation-In-Place). Double seals are available as a tandem arrangement or mounted back-to-back. Connections A variety of connections are available, such as sterile threads to DIN PN 16 and sterile flanges to DIN PN 16. See page 3.
5 Performance range Sanitary pumps Performance range, -pole p [kpa] H 5 Hz 15 Contra ll Euro-HYGIA II 5 5 Contra I Euro-HYGIA II MAXANA MAXA F&B-HYGIA II 3 3 Euro-HYGIA I *durietta F&B- HYGIA I Q [m³/h] Q [l/s] TM Performance range, -pole p [kpa] H 5 Hz 5 5 SIPLA 3 3 MAXA MAXANA 15 Euro-HYGIA II F&B-HYGIA II 1 1 Euro-HYGIA I F&B-HYGIA I 5 5 *durietta Q [m³/h] Q [l/s] TM *durietta : The performance range is shown on page 1. 5
6 Euro-HYGIA Sanitary pumps Euro-HYGIA Fig. 1 Euro-HYGIA Euro-HYGIA I and II Technical data GR8963 Construction Euro-HYGIA pumps are single-stage, end-suction centrifugal pumps, designed to meet the hygienic requirements of sterile process technology. The pumps are available in a variety of flexible versions. The pumps are CIP and SIP capable in compliance with the DIN EN 16 performance criteria. The design fulfils the following requirements: QHD criteria EHEDG recommendations for CIP cleanability GOST sanitary standard (Russia). Head: up to 7 m Flow rate: up to 18 m 3 /h Euro-HYGIA III (on request): up to 5 m 3 /h Operating pressure: up to 16 bar Operating temperature: 95 C (up to 15 C on request) Sterilisation temperature: 1 C (SIP) Applications The unique hygienic design and the materials used make the Euro-HYGIA pumps suitable for these applications and products: Life science/pharmaceutical industries pure water systems (WFI) biotechnology infusion nutrient and alcohol infusions filling/bottling systems. Personal care pure water lotions perfumes. Food and beverage industries breweries dairies soft drink mixing yeast processes. Other industries cleaning solutions (CIP systems) water treatment semi-conductor manufacturing metal surface treatment. Fig. Certification The pumps comply with these surface finish requirements: Standard pump version: 3A1 Optional: 3A, 3A3. For explanation, see Certification, page 55. The pump housing is made of heavy-duty, rolled and deep-drawn CrNiMo steel to DIN EN 1./1.35, the equivalent of AISI 316L. Three impeller types are available, depending on the applications: Semi-open, closed and free-flow impeller. See page 51. The pumps have a mechanical shaft seal and a fancooled asynchronous motor to enclosure class IP55. Fig Sectional drawing of Euro-HYGIA I Bloc-SUPER on combi foot 5 TM
7 Euro-HYGIA Sanitary pumps Materials Pos. Component Material DIN/EN 1 Impeller CrNiMo steel Pump housing CrNiMo steel Design variations See page. Mechanical shaft seal Grundfos offers these shaft seal arrangements: single seal double seal, tandem double seal, back-to-back. As standard, the Euro-HYGIA is fitted with a single, inboard, mechanical shaft seal with an optimum position in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP, according to the criteria of hygienic design. Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combinations are available on request. See page / / Shaft seal Sterile applications: SiC/SiC/EPDM Hygienic applications: Carbon/stainless steel/epdm or FKM Pump shaft CrNiMo steel Shroud Stainless steel 6 Foot Stainless steel/cast iron Standard variation Euro-HYGIA Adapta Euro-HYGIA Adapta SUPER Euro-HYGIA Bloc Euro-HYGIA Bloc-SUPER Variation on request Euro-HYGIA Adapta -V Euro-HYGIA Bloc-V Euro-HYGIA VE Euro-HYGIA CN Euro-HYGIA tronic Description Horizontal installation, Adapta motor stool Horizontal installation, Adapta motor stool, motor with stainless steel shroud Horizontal installation Horizontal installation, motor with stainless steel shroud Description Vertical installation, Adapta motor stool Vertical installation Vertical tank installation Horizontal installation, long-coupled version mounted on base plate Horizontal/vertical installation, motor with built-in frequency converter (up to kw) Standard connection Grundfos offers threads to DIN as standard for Euro-HYGIA pumps. Connections on request Threads: Aseptic threads to DIN Flanges: Aseptic flanges to DIN APV flanges Flanges to DIN EN 19-1 (DIN 633) Kremo flanges to DIN EN 19-1 (DIN 633/). Clamps: Clamps to DIN 3676 Clamps for Tri-Clamp /Tri-Clover. Note: Not all pump sizes are available with all connection types. See pages 3 to 35. For other connection types as well as applications and design of connections, see pages 8 to 33. Features and benefits A wide range of foot options for motor and pump. Extremely reliable operation under most working conditions. Optimised hydraulics for high efficiency - reduced power consumption. Multi-function inducer for NPSH reduction or pumping of liquids containing gas (Euro-HYGIA II). Motors for special voltages and frequencies. Euro-HYGIA, Adapta and Euro-HYGIA CN with explosion-proof or flameproof three-phase motors available for ATEX applications. Motors for variable-speed drive with built-in frequency converter, available for motor sizes up to kw. Mobile pumps mounted on two-wheel stainless steel trolley with on/off switch and electric cable. DN 15 diaphragm valve drain for sterile processes. DN 15 drain connection. Heating/cooling jacket for pump housing. Integral flange ring for bolted housing closure (HPM). Special paint finish for the motor and the cast iron/ steel parts. Surface treatment As standard, all wetted parts are electro-polished to improve corrosion-resistance and surface finish. 7
8 F&B-HYGIA Sanitary pumps F&B-HYGIA Fig. F&B-HYGIA F&B-HYGIA I and II Technical data GrA396 Construction F&B-HYGIA single-stage, end-suction centrifugal pumps are designed to meet the hygienic requirements of sterile process technology. The pumps are CIP and SIP capable in compliance with the DIN EN 16 performance criteria. The design fulfils the following requirements: QHD criteria EHEDG recommendations for CIP cleanability. For explanation, see Certification, page 55. Head: up to 7 m Flow rate: up to 15 m 3 /h Operating pressure: up to 16 bar Operating temperature: 95 C Sterilisation temperature: 1 C (Sterilisation-In-Place, SIP) Applications The unique hygienic design and the materials used make the F&B-HYGIA pumps suitable for these products: Beverages Beer, soft drinks, alcohol, wine, fruit drinks, yeast, etc. Dairy products Milk, whey, cream, condensed milk, etc. Fig. 5 Certification The pump housing is made of heavy-duty, rolled and deep-drawn CrNiMo steel to DIN EN 1., the equivalent of AISI 316L. F&B-HYGIA pumps are fitted with a semi-open impeller. See page 51. The pumps have a mechanical shaft seal (optionally flushed) and a fan-cooled, asynchronous motor to enclosure class IP Confectionery Syrup, sugar solutions, etc. Meat Liquid fat, frying oil, smokehouse spray, blood, etc. 3 6 TM Fig. 6 Sectional drawing of F&B-HYGIA K on combi foot 8
9 F&B-HYGIA Sanitary pumps Materials Pos. Component Material DIN EN 1 Impeller CrNiMo steel 1. Pump housing CrNiMo steel 1. 3 Shaft seal Hygienic applications: Carbon/stainless steel/epdm or FKM Pump shaft CrNiMo steel Motor 6 Foot Stainless steel/cast iron Design variations Standard variation F&B-HYGIA K F&B-HYGIA K-SUPER See page. Mechanical shaft seal Grundfos offers these shaft seal arrangements: single seal single seal, flushed. As standard, the F&B-HYGIA is fitted with a single, inboard, mechanical shaft seal with an optimum position in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP, according to the criteria of hygienic design. Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combinations are available on request. See page 53. Description Horizontal installation with plug-in shaft and multi-functional motor stool. Horizontal installation with plug-in shaft and multi-functional motor stool and motor with stainless steel shroud. Standard connections Grundfos offers threads to DIN as standard for F&B-HYGIA pumps. Connections on request Flanges: Kremo flanges to DIN EN 19-1 (DIN 633/). Clamps: Clamps for Tri-Clamp /Tri-Clover. For other connection types as well as applications and design of connections, see pages 8 to 33. Features and benefits A wide range of foot options for motor and pump. Extremely reliable operation under most working conditions. Optimised hydraulics for high efficiency - reduced power consumption. Motors for special voltages and frequencies on request. Mobile pumps mounted on two-wheel stainless steel trolley with on/off switch and electric cable. Surface treatment As standard, all chrome-steel parts are electro-polished to improve corrosion-resistance and surface finish. 9
10 Contra Sanitary pumps Contra The design fulfils the following requirements: QHD criteria EHEDG recommendations. GOST sanitary standard (Russia). GR8961 Fig. 7 Contra Contra I and II Technical data Head: up to 16 m Flow rate: up to 55 m 3 /h Operating pressure: up to 5 bar Operating temperature: 95 C (up to 15 C on request) Sterilisation temperature: 1 C (SIP) Applications The unique hygienic design and the materials used make the Contra pumps suitable for these applications: Food and beverage industry breweries and dairies carbonising systems food processing plants. Pharmaceutical and related industries purification systems pure-water systems (WFI) personal care. Other industrial applications surface treatment systems water processing systems CIP feeding systems. Fig. 8 Certification The pumps comply with these surface finish requirements: Standard pump version: 3A1 Optional: 3A, 3A3. For explanation, see section Certification, page 55. The pump housing is made of rolled and forged stainless steel to DIN EN 1./1.35, the equivalent of AISI 316L. This guarantees a homogeneous, pore-free surface, in contrast to cast materials. The Contra pumps have open diffusers. The design ensures that O-ring seals for pump housing and impeller are located to meet the criteria of hygenic design with metal-to-metal contact and that there are no dead ends in the pump housing. Contra pumps are fitted with a semi-open impeller as standard. See page 51. The vertical versions are fully self-draining through the suction port of the pumps. The pumps have a mechanical shaft seal and a fancooled asynchronous motor to enclosure class IP Construction Contra single-stage or multi-stage, end-suction centrifugal pumps are designed to meet the hygienic requirements of sterile process technology. The pumps are available in a variety of flexible versions. The pumps are CIP and SIP capable in compliance with the DIN EN 16 performance criteria. They also meet the GMP requirements regarding FDA-approved materials. Fig Sectional drawing of Contra I Bloc-SUPER on combi foot TM
11 Contra Sanitary pumps Materials Pos. Component Material EN/DIN 1 Impeller CrNiMo steel Pump housing CrNiMo steel 3 Shaft seal Pump shaft CrNiMo steel Design variations See page. Sterile applications: SiC/SiC/EPDM Hygienic applications: Carbon/ stainless steel/epdm or FKM 5 Motor 6 Shroud Stainless steel 7 Foot Stainless steel/cast iron Standard variation Contra Adapta Contra Adapta SUPER Contra Adapta -V Contra Bloc Contra Bloc-SUPER Variation on request Contra Bloc-V Contra CN Contra tronic Mechanical shaft seal Grundfos offers these shaft seal arrangements: 1./ / / 1.6 Description Horizontal installation, Adapta motor stool Horizontal installation, Adapta motor stool, motor with stainless steel shroud Vertical installation, Adapta motor stool Horizontal installation Horizontal installation, motor with stainless steel shroud Description Vertical installation Horizontal installation, long-coupled version mounted on base plate Horizontal/vertical installation, motor with built-in frequency converter (up to 18.5 kw) single seal double seal, tandem double seal, back-to-back. As standard, the Contra is fitted with a single, inboard, mechanical shaft seal with an optimum position in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP according to the criteria of hygienic design. Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combinations are available on request. Standard connection Grundfos offers threads to DIN as standard for Contra pumps. Connections on request Threads: Aseptic threads to DIN Flanges: Aseptic flanges to DIN APV flanges Flanges to DIN EN 19-1 (DIN 633) Kremo flanges to DIN EN 19-1 (DIN 633/). Clamps: Clamps to DIN 3676 Clamps for Tri-Clamp /Tri-Clover. Note: Not all pump sizes are available with all connection types. See page 37 ff. For other connection types as well as applications and design of connections, see pages 8 to 33. Features and benefits A wide range of foot options for motor and pump. Extremely reliable operation under most working conditions. Optimised hydraulics for high efficiency - reduced power consumption. Contra Adapta and CN with explosion-proof or flameproof motors available for ATEX applications. Motors with special voltages and frequencies. Pump with water-cooled motor for clean-room applications. Adapta tronic versions fitted with motors for variable speed drive with built-in frequency converter, available for motor sizes up to 18.5 kw. Flush or barrier fluid systems for tandem or back-toback double mechanical seals. Mobile pumps mounted on two-wheel trolley with on/off switch. Special paint for motor, cast iron and carbon steel parts (except for Adapta Bloc). See page 53. Surface treatment As standard, all wetted parts are electro-polished to improve corrosion-resistance and surface finish. 11
12 durietta Sanitary pumps durietta Construction durietta are compact, end-suction, single-stage or multi-stage centrifugal pumps. The design fulfils the following requirement: GOST sanitary standard (Russia). GrA397 Fig. 1 durietta durietta pumps Technical data Head: up to 7 m Flow rate: up to 6 m 3 /h Operating pressure: up to 8 bar Temperature range: C to 9 C. Applications durietta pumps are suitable for these applications: Fig. 11 Certification The laminated, stainless steel pump components are manufactured to DIN EN and DIN EN 1.. The impeller types available are semi-open or closed, depending on the applications. See page 51. The pumps have a mechanical shaft seal and an asynchronous motor to enclosure class IP Food and beverage industry pumping in micro-breweries and dairies bottling systems for liquids food processing plants drinking water systems. Pharmaceutical and related industries purification systems personal care. Other industrial applications semi-conductor manufacturing plate heat exchangers. Fig. 1 Sectional drawing of durietta / K SUPER on combi foot Materials 3 7 TM Pos. Component Material EN/DIN 1 Impeller CrNiMo steel 1. Pump housing CrNiMo steel 1. 3 Shaft seal SiC/SiC or Carbon/stainless steel and EPDM or FKM Pump shaft CrNiMo steel Motor 6 Shroud Stainless steel Foot Stainless steel
13 durietta Sanitary pumps Design variations Standard variation durietta K durietta K SUPER Variation on request durietta tronic See page. Mechanical shaft seal Grundfos offers these shaft seal arrangements: single seal double seal, tandem (maximum four stages) As standard the durietta is fitted with a mechanical shaft seal with an optimum position in the pumped liquid. This ensures lubrication and cooling. Standard seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combinations are available on request. See page 53. Description Horizontal installation, monobloc Horizontal installation, motor with stainless steel shroud on stainless steel foot with elastomer base Description Horizontal installation, motor with built-in unshrouded frequency converter. Only available for.75 kw. Surface treatment As standard, wetted parts are blasted. Electro-polished wetted parts are also available on request. Standard connection Grundfos offers threads to DIN as standard for durietta pumps. Connections on request Threads: Threads, SMS. Flanges: Flanges to DIN EN 19-1 (DIN 6). Clamps: Tri-Clover / Tri-Clamp Note: Not all pump sizes are available with all connection types. See page 3 to. For other connection types as well as applications and design of connections, see pages 8 to 33. Features and benefits Motor for special voltages on request Motor with built-in frequency converter for output regulation (does not apply to the K SUPER version) Mobile pumps mounted on stainless steel two-wheel trolley with on/off switch (on request) Special paint finish for the motor (on request). 13
14 SIPLA Sanitary pumps SIPLA Construction SIPLA are single-stage, self-priming, side-channel pumps. The design fulfils the following requirement: GOST sanitary standard (Russia). GR8965 Fig. 13 SIPLA SIPLA pumps Technical data Head: up to 56 m Flow rate: up to 8 m 3 /h (SIPLA on request): up to 9 m 3 /h Operating pressure: up to 1 bar Operating temperature: 95 C Sterilisation temperature: 1 C (SIP) Applications The exceptional self-priming capability make the SIPLA pumps suitable for these applications: Food and beverage industry transfer of yeast transfer of cheese whey. Pharmaceutical industry transfer of glycerine. Fig. 1 Certification The pump housing and front cover are made of precision-cast stainless steel to DIN EN 1.. The impeller nut is made of stainless steel to DIN EN 1., the equivalent of AISI 316L. SIPLA pumps are fitted with an open star impeller as standard. See page 51. The pump shaft is made of stainless steel to DIN EN 1.571, the equivalent of AISI 316TI. Thanks to its unique side-channel design, the SIPLA pump is capable of handling liquids with a high air content as in CIP return systems. The pumps have a mechanical shaft seal and a fancooled asynchronous motor to enclosure class IP Other industrial applications CIP return pumping applications involving liquids with a high air content filtration systems TM Fig. 15 Sectional drawing of SIPLA Bloc-SUPER on stainless steel ball feet 1
15 SIPLA Sanitary pumps Materials Pos. Component Material EN/DIN 1 Impeller CrNiMo steel 1. Pump housing CrNiMo steel 1. 3 Shaft seal Hygienic applications: Carbon/stainless steel/ EPDM or FKM Pump shaft CrNiMo steel Motor 6 Shroud Stainless steel 7 Foot Stainless steel/cast iron Design variations Standard variation SIPLA Adapta SIPLA Adapta SUPER SIPLA Bloc SIPLA Bloc-SUPER Variation on request SIPLA CN SIPLA tronic See page. Mechanical shaft seal Grundfos offers this shaft seal arrangement: single seal SIPLA pumps are fitted with a single, inboard, mechanical shaft seal with an optimum position in the pumped liquid. This ensures lubrication, cooling as well as CIP and SIP. As standard, the SIPLA pump is fitted with a shaft seal with carbon/stainless steel seal faces and EPDM or FKM O-rings. Shaft seals with SiC/SiC seal faces and EPDM or FKM O-ring are available on request. See page 53. Description Horizontal installation, Adapta motor stool Horizontal installation, Adapta motor stool, motor with stainless steel shroud Horizontal installation Horizontal installation, motor with stainless steel shroud Description Horizontal installation, long-coupled version mounted on base plate Horizontal/vertical installation, motor with built-in frequency converter (up to 7.5 kw for Bloc pumps, and up to kw for Adapta pumps) Standard connection As standard Grundfos offers threads to DIN for SIPLA pumps. Connections on request Flanges: Flanges to DIN EN 19-1 (DIN 633/). Clamps: Clamps to DIN 3676 Clamps for Tri-Clamp /Tri-Clover. For other connection types as well as applications and design of connections, see pages 8 to 33. Features and benefits A wide range of foot options for motor and pump Extremely reliable operation under most working conditions Optimised hydraulics for high efficiency - reduced power consumption Motors for variable speed drive with built-in frequency converter, "tronic", available for motor sizes up to 7.5 kw for Bloc pumps, and up to kw for Adapta pumps ATEX-certified pumps available on request Mobile pumps mounted on two-wheel trolley with on/off switch. Surface treatment As standard, all wetted parts are electro-polished to improve corrosion-resistance and surface finish. 15
16 MAXA and MAXANA Sanitary pumps MAXA and MAXANA TM Construction The MAXA and MAXANA are single-stage, end-suction, centrifugal pumps. The pumps are available in a variety of flexible versions. The design fulfils the following requirements: EHEDG recommendations for CIP cleanability. Only valid for certain models. GOST sanitary standard (Russia). Fig. 16 MAXA and MAXANA Technical data MAXA pumps Head: 97 m Flow rate: up to 8 m 3 /h Operating pressure: up to 1 bar Operating temperature: 95 C (up to 15 C on request) Sterilisation temperature: 1 C (SIP) MAXANA pumps Head: up to 97 m Flow rate: up to 165 m 3 /h Operating pressure: up to 1 bar Operating temperature: 95 C (up to 15 C on request) Sterilisation temperature: 1 C (SIP) Applications The MAXA and MAXANA pumps are suitable for these applications: Food and beverage industry gentle pumping of mash and wort beer filtration (hot side) liquid transfer in dairies and food processing plants. Fig. 17 Certification For explanation, see Certification, page 55. Requirements complied with: Pump type Standard MAXA 3A and 3A*. MAXANA 3A *Applies to MAXA 1-, 1-5, 15-5, 15-5, - The major dimensions and characteristics of the pumps are according to DIN EN 733 and DIN EN 858. The pump housing is made of heavy-duty, rolled and deep-drawn stainless steel to DIN EN 1.. The back plate is made of rolled stainless steel to DIN EN The pumps feature closed steel impellers with optimised blade entry angles to DIN EN See page Other industrial applications water treatment plants chemical handling systems applications involving liquids with a high content of solid particles environmental systems bio fuel systems TM Fig. 18 Sectional drawing of MAXANA-CN on base plate 16
17 MAXA and MAXANA Sanitary pumps Materials Pos. Component Material EN/DIN 1 Impeller CrNiMo steel 1./ 1.6 Pump housing CrNiMo steel 1. 3 Shaft seal Design variations See page. Mechanical shaft seal Grundfos offers these shaft seal arrangements: single seal double seal, tandem double seal, back-to-back. As standard, MAXA and MAXANA pumps are fitted with a single, inboard, mechanical shaft seal with an optimum position in the pumped liquid. This ensures efficient cleaning, cooling and lubrication. The mechanical shaft seal is designed to DIN EN Standard single seals have carbon/stainless steel seal faces and EPDM O-rings. Other seal face material combinations are available on request. See page 53. Sterile applications: SiC/ SiC/EPDM Hygienic applications: Carbon/stainless steel/ EPDM or FKM Pump shaft CrNiMo steel 5 Bearing bracket Stainless steel 6 Coupling 7 Motor 8 Base plate Standard variation MAXA L MAXA CN MAXANA Adapta MAXANA Bloc Variation on request MAXA CN Maxa VE MAXA tronic MAXANA CN MAXANA L MAXANA tronic Steel Chrome steel Description Horizontal installation 1.571/ 1.6 Horizontal installation, mounted on base plate Horizontal installation, Adapta motor stool Horizontal installation Description Horizontal installation, mounted on base plate Vertical tank installation Horizontal installation, motor with built-in frequency converter (up to kw) Horizontal installation, mounted on base plate Horizontal installation, mounted on pump foot or motor foot Horizontal installation, motor with built-in frequency converter (up to kw) Standard connection Grundfos offers Kremo flanges to DIN EN 19-1 as standard for MAXA and MAXANA pumps. As standard MAXA pumps also come with flanges to DIN EN Note: Not all MAXA pump sizes are available with all connection types. See page 7. Connections on request For other connection types as well as applications and design of connections, see pages 8 to 33. Features and benefits A wide range of foot or base plate options for motor and pump. Extremely reliable operation under most working conditions. Optimised hydraulics for high efficiency - reduced power consumption. Optional location of discharge port on top, on right or on left side of pump. Double mechanical seals, depending on model, with flushing or barrier fluid. Stuffing box in stead of mechanical shaft seal, single or flushed with C-bearing support to DIN EN 858 and shaft sleeve. Motors with special voltages and frequencies. Adapta and CN available with a flameproof threephase motor for ATEX applications. Motors for variable speed drive with built-in frequency converter as "tronic", available for motor sizes up to kw. Pump housing drain connection DN 15; other sizes available. Housing with heating jacket. Applies only to MAXANA. Special paint for motor and steel components. Surface treatment As standard, all wetted parts are made of corrosionresistant chrome-nickel-molybdenum steel. Grundfos offers industrial, electro-polished variants. 17
18 Identification Sanitary pumps Type keys Euro-HYGIA Example Euro-HYGIA I BYY 3. Pump range Size Design Nominal diameter of suction port (DN) Nominal diameter of discharge port (DN) Motor power (P) [kw] Number of poles F&B-HYGIA Example F&B-HYGIA I KYY. Pump range Size Design Nominal diameter of suction port (DN) Nominal diameter of discharge port (DN) Motor power (P) [kw] Number of poles Contra Example Contra I/1 BYY Pump range Size/stages Design Nominal diameter of suction port (DN) Nominal diameter of discharge port (DN) Motor power (P) [kw] Number of poles durietta Example durietta / KYY Pump range Size/stages Design Nominal diameter of suction port (DN) Nominal diameter of discharge port Motor power (P) [kw] Number of poles SIPLA Example SIPLA 3.1 BYY Pump range Size Design Nominal diameter of suction port (DN) Nominal diameter of discharge port (DN) Motor power (P) [kw] Number of poles MAXA Example MAXA 8-5 KYY Pump range Size Design Nominal diameter of suction port Nominal diameter of discharge port Motor power (P) [kw] Number of poles MAXANA Example MAXANA 3- BYY Pump range Size Design Nominal diameter of suction port (DN) Nominal diameter of discharge port (DN) Motor power (P) [kw] Number of poles Design* A D D Adapta -SUPER-DOC A D S Adapta -SUPER A D V Adapta -V A D X Adapta -SUPER/quiet A D Y Adapta A T D Adapta -SUPER-tronic-DOC A T S Adapta -SUPER-tronic A V E Adapta -VE B T S Bloc-SUPER-tronic B V E Bloc-VE B V S Bloc-V-SUPER B V X Bloc-V-SUPER/quiet B V Y Bloc-V B Y S Bloc-SUPER B Y X Bloc-SUPER/quiet B Y Y Bloc C H Y CN-special grease (hot) C N S CN-Super C N V CN-V C N Y CN C V Y CV C Y Y C K V Y K-V K Y S K-SUPER K Y T K, portable K Y X K-SUPER/quiet K Y Y K L Y S L-SUPER L Y X L-SUPER/quiet L Y Y L S U B Bloc-submersible motor V E Y VE * See page 19 for clarification 18
19 Product range Sanitary pumps Sanitary pumps Pump range Euro-HYGIA I Euro-HYGIA II F&B-HYGIA I F&B-HYGIA II Contra I Contra II durietta SIPLA 3.1 SIPLA 6.1 SIPLA 1.1 SIPLA 18.1 SIPLA 8.1 SIPLA 5.1 SIPLA 65.1 SIPLA 9.1 MAXA MAXANA Hydraulic data Max. head Max. flow rate [m 3 /h] Max. operating temperature [ C] Max. temperature [ C] on request Max. operating pressure [bar] Max. pump efficiency [%] Motor data Motor power [kw] Design Bloc Bloc SUPER Bloc-V VE Adapta Adapta SUPER Adapta -V K K-SUPER K-V CN L Tronic Materials Pump housing: CrNiMo stainless steel DIN EN 1. Pump housing: Stainless steel DIN EN 1./1.35 Pump housing: Hastelloy Pump housing: Duplex Pipe connections See pages 8 to 33 Impeller types Semi-open Closed Two-channel (closed) Free-flow Star Standard. Available on request. 19
20 Product range Sanitary pumps Design variations Grundfos offers each pump range in different designs. Principal sketches of each design variant are shown below. Not all pumps are available in the design variations shown. Bloc on motor foot TM Adapta Fig. Euro-HYGIA Adapta on cast iron foot Adapta -SUPER TM Fig. 19 Euro-HYGIA Bloc on motor foot Bloc on cast iron foot TM TM K Fig. 5 Euro-HYGIA Adapta -SUPER on stainless steel combi foot Fig. Euro-HYGIA Bloc on cast iron foot Bloc-SUPER Fig. 1 Euro-HYGIA Bloc-SUPER with shroud on stainless steel combi foot Bloc on stainless steel trolley TM Fig. 6 F&B-HYGIA K on combi foot K-SUPER TM 86 8 Fig. Euro-HYGIA Bloc on stainless steel trolley TM Fig. 7 F&B-HYGIA K-SUPER on combi foot Adapta on stainless steel trolley TM CN TM Fig. 8 Euro-HYGIA Adapta on stainless steel trolley TM Fig. 3 Euro-HYGIA CN on base plate
21 Product range Sanitary pumps Adapta -V F&B-HYGIA II Design Version number K 1) K-SUPER ) ) Plug-in shaft. ) SUPER = motor with stainless steel shroud. Contra I Fig. 9 Euro-HYGIA Adapta -V on pedestal and with suction elbow connection The tables below state possible designs and versions of each pump range. Each version number is described in the version key, page 3. Euro-HYGIA I Design Euro-HYGIA II F&B-HYGIA I Version number Adapta 1) Adapta -SUPER ) Adapta -V 1) Bloc Bloc-SUPER ) Bloc-V VE CN ) Size I. ) SUPER = motor with stainless steel shroud. Design Version number Adapta 1) Adapta -SUPER ) Adapta -V 1) Bloc Bloc-SUPER ) Bloc-V VE CN ) Size II up to frame size 16; frame size 18 is size III. ) SUPER = motor with stainless steel shroud. TM Design Contra II durietta SIPLA 3.1 Version number Adapta 1) Adapta -SUPER ) Adapta -V 1) Bloc Bloc-SUPER ) Bloc-V CN ) Size I. ) SUPER = motor with stainless steel shroud. Design Version number Adapta 1) Adapta -SUPER ) Adapta -V 1) Bloc Bloc-SUPER ) Bloc-V CN ) Size II up to frame size 16; frame size 18 is size III. ) SUPER = motor with stainless steel shroud. Design K 1) K-SUPER ) 18 Version number K-V ) Plug-in shaft. ) SUPER = motor with stainless steel shroud and stainless steel foot with elastomer base Design Version number Adapta 1) Adapta -SUPER ) Bloc Bloc-SUPER ) 18 CN ) Size I. ) SUPER = motor with stainless steel shroud. Design Version number K 1) K-SUPER ) ) Plug-in shaft ) SUPER = motor with stainless steel shroud. 1
22 Product range Sanitary pumps SIPLA 6.1 Design Version number Adapta 1) Adapta -SUPER ) Bloc Bloc-SUPER ) 18 5 CN ) Size I. ) SUPER = motor with stainless steel shroud. SIPLA 1.1 Design Version number Adapta 1) Adapta -SUPER ) Bloc Bloc-SUPER ) 18 5 CN ) Size I. ) SUPER = motor with stainless steel shroud. SIPLA 18.1 Design Version number Adapta 1) Adapta -SUPER ) Bloc Bloc-SUPER ) 18 5 CN ) Size II. ) SUPER = motor with stainless steel shroud. SIPLA 8.1 Design Version number Adapta 1) Adapta -SUPER ) Bloc Bloc-SUPER ) 18 5 CN ) Size II. ) SUPER = motor with stainless steel shroud. SIPLA 5.1 Design Version number Adapta 1) Adapta -SUPER ) Bloc Bloc-SUPER ) CN ) Size II. ) SUPER = motor with stainless steel shroud. SIPLA 65.1 Design Version number Adapta 1) Adapta -SUPER ) 31 Bloc 5 Bloc-SUPER ) CN ) Size III. ) SUPER = motor with stainless steel shroud. SIPLA 9.1 Design Version number Adapta 1) Adapta -SUPER ) 31 Bloc 5 Bloc-SUPER ) CN ) Size III. ) SUPER = motor with stainless steel shroud. MAXA Design Version number Adapta 1) Adapta ) Adapta -V 1) Adapta -V ) VE L 3) C ) CN ) Size II. ) Size III. 3) Bearing-supported plug-in shaft. ) CN with shaft sleeve. MAXANA Design Version number Adapta 1) Adapta ) Adapta -SUPER 3) Bloc L ) C 5) CN ) Size II. ) Size III. 3) SUPER = motor with stainless steel shroud. ) Bearing-supported plug-in shaft. 5) CN with shaft sleeve.
23 Product range Sanitary pumps Version key Version number Description 1 On cast iron foot On stainless steel foot 3 Without foot/stainless steel ball feet On stainless steel ball feet 5 On motor foot 6 On motor foot with carbon steel support 7 On motor foot with stainless steel support 8 On stainless steel pedestal without suction elbow 9 On stainless steel pedestal with suction elbow 1 Without pedestal and suction elbow 1) 11 Without pedestal but with suction elbow 16 On vertical frame without suction elbow 1) 18 On stainless steel trolley, normal wheels 19 On stainless steel trolley, anti-static wheels 1 On pump and motor support feet ( frame size 11) On Adapta foot ( 5 kw, size III) 3 On stainless steel combi foot Wall-mounting (Euro-HYGIA : Only available as HPM, Contra; 3 stages are standard) 5 Without base plate ) 6 With coupling (< 15 kw only with DKM spacer) ) 7 With spacer coupling ( 15 kw only; < 15 kw on request) ) 8 Without coupling ) 9 Without spacer coupling ) 3 With motor ) 31 Without motor ) 3 On carbon steel base plate ) 33 On stainless steel base plate ) 3 Stand-proof coupling guard ) 35 Chemical standard, base plate with anchor bolt holes ) 5 With built-in frequency converter (tronic), from 1.5 to 7.5 kw 51 Motor with increased-safety explosion protection (EEx e II T1-T3) 3) 5 Motor with flameproof-enclosure explosion protection (EEx de IIC T1-T) 3) 53 Hydraulic drive 5 Electric motor and hydraulic drive through second shaft end 57 Tank installation with base plate and discharge pipe 58 Tank installation without base plate and without discharge pipe 59 Tank installation with base plate and without discharge pipe 6 KLM (clamp ring), see fig HPM (flange), see fig. 3 6 Vertical foot with fixed suction elbow 1) In connection with Adapta size III. ) Design CN. All combinations are possible with base plate mounted. Motor and coupling size as well as type should be provided to determine base plate size. 3) For further information on pumps conforming to the ATEX 9/9/EC Directive, contact Grundfos. Sealing of HYGIA pump housing KLM (clamp ring) HPM (flange)* TM , TM Fig. 3 KLM and HPM housing sealing 3
24 Product range Sanitary pumps Motor ranges Euro-HYGIA I Contra I P [kw] -pole -pole -pole -pole The grey shaded areas indicate non-available motors. Euro-HYGIA II P [kw] stage -stage 3-stage -stage 5-stage The grey shaded areas indicate non-available motors. 6-stage 1-stage P [kw] -pole -pole The grey shaded areas indicate non-available motors. F&B-HYGIA I P [kw] -pole -pole The grey shaded areas indicate non-available motors. F&B-HYGIA II P [kw] -pole -pole ) The grey shaded areas indicate non-available motors. 1) Not available as EFF 1 motor. Contra II P [kw] durietta -pole 1-stage -stage 3-stage -stage The grey shaded areas indicate non-available motors. P [kw] pole 1-stage -stage 3-stage -stage 5-stage The grey shaded areas indicate non-available motors. 5-stage 6-stage -pole 1-stage -pole 1-stage
25 Product range Sanitary pumps SIPLA -pole P [kw] Size The grey shaded areas indicate non-available motors. MAXA, -pole P [kw] pole Size The grey shaded areas indicate non-available motors. MAXA, -pole P [kw] MAXANA, -pole MAXANA, -pole -pole Size The grey shaded areas indicate non-available motors. P [kw] pole Size The grey shaded areas indicate non-available motors. -pole P [kw] Size The grey shaded areas indicate non-available motors. 5
26 Product range Sanitary pumps Electrical data of standard motors -pole, 3 x -/38-15 V P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] pole, 3 x 38-15/66-69 V P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] pole, 3 x -/38-15 V P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] pole, 3 x 38-15/66-69 V Electrical data of EFF 1 MG motors -pole, 3 x - V Δ/38-15 V Y P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] / / / / / / / pole, 3 x V Δ P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] pole, 3 x - V Δ/38-15 V Y P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] 1.1.7/ / / / / pole, 3 x V Δ P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ] P [kw] I 1/1 [A] cos ϕ η [%] n [min -1 ]
27 Product range Sanitary pumps Electrical data of standard motors with built-in frequency converter -pole, 3 x V -pole, 3 x V P [kw] I 1/1 [A] P [kw] I 1/1 [A] The values depend on the motor make. Motor protection Three-phase motors must be connected to a motor-protective circuit breaker. All three-phase standard motors can be connected to an external frequency converter. The connection of a frequency converter will often overload the motor insulation system, and the motor will be more noisy than during normal operation. In addition, large motors are loaded by bearing currents caused by the frequency converter. In the case of frequency converter operation, bear the following considerations in mind: In - and -pole motors of frame size 5 and upwards, one of the motor bearings should be electrically isolated to prevent damaging currents from passing through the motor bearings. In the case of noise-sensitive applications, the motor noise can be reduced by fitting a du/dt filter between the motor and the frequency converter. In particularly noise-sensitive applications, we recommend to fit a sinusoidal filter. The length of the cable between motor and frequency converter affects the motor load. Check that the cable length meets the specifications laid down by the frequency converter supplier. For supply voltages between 5 and 69 V, fit a du/ dt filter to reduce voltage peaks or use a motor with reinforced insulation. For supply voltages of 69 V, use a motor with reinforced insulation and fit a du/dt filter. 7
28 Connection selection guide Sanitary pumps Selection of connection according to application The table below is intended as a general guide. Selection of connection often depends on local conditions. Connection Beverages Food Application Life science and personal care Industrial applications Cleaning Type Standard Beer Wine Juice Alcohol Soft drinks Confectionary Dairy products Frying oil Liquid foods (processing) Syrup Pumpable meat (packing) Pure water Biotechnology products Perfumes and lotions Glue and paint Purification products Chemical products Industrial wastewater and effluent Surface treatment products Biofuel CIP SIP Threads Flanges Aseptic threaded connection DIN Threaded connection DIN Threaded connection, SMS ISO 37 Threaded connection, DS DS 7 Threaded connection, RJT BS85-5 Threaded connection, IDF ISO 853 BS 85- Threaded connection (male), GAZ DIN ISO 8 Tapped connection (female) DIN EN 16-1 Aseptic flange DIN Flange, APV-FN1/APV-FG1 ISO Flange DIN EN 19-1 Kremo flange DIN EN 19-1 Flange, ANSI 15 LB RF ANSI Clamp DIN 3676 Clamp ISO 85 BS 85-3 Clamp, Tri-Clamp /Tri-Clover ASME BPE Clamp, ISO Clamp, SMS Stub DIN 1185 Typically used. Clamps 8
29 Connection selection guide Sanitary pumps Selection of connection according to pump type The table below is intended as a general guide. Selection of connection often depends on local conditions. Type Connection Rated pressure Standard Sanitary standard 3A 3A1 3A 3A3 Euro-HYGIA I Euro-HYGIA II F&B-HYGIA I F&B-HYGIA II Pump type Contra I Contra II durietta SIPLA MAXA MAXANA NOVAlobe* Threads Flanges Clamps Aseptic threaded connection PN 5- DIN Threaded connection PN 16- DIN Threaded connection, SMS ISO 37 Threaded connection, DS ISO 37 Threaded connection, RJT BS85-5 Threaded connection, IDF ISO 853 BS85- Threaded connection (male), GAZ PN 1 DIN ISO 8 Tapped connection (female) PN 1 DIN EN 16-1 Aseptic flange PN 1-5 DIN Flange, APV-FN1/APV-FG1 PN 1 APV Flange PN 1 DIN EN 19-1 Flange PN 16 DIN EN 19-1 Kremo flange PN 1 DIN EN 19-1 Kremo flange PN 16 DIN EN 19-1 Flange, ANSI 15 LB RF PN 1-16 ANSI Clamp DIN 3676 Clamp ISO 85 BS85-3 Clamp, Tri-Clamp /Tri-Clover ASME BPE Clamp, ISO Clamp, SMS Stub DIN 1185 * See the NOVAlobe data booklet Standard Available on request 9
30 Connection selection guide Sanitary pumps Design The following tables show the design of the different connection types. Threads Connection Standard Design Aseptic threaded connection DIN Typical applications: Life science/pharmaceutical industry. TM Threaded connection DIN Typical applications: Food and beverage industry. TM Threaded connection, SMS Threaded connection, DS ISO 37 DS 7 Typical applications: Food and beverage industry. TM Threaded connection, RJT BS85-5 Typical applications: Life science/pharmaceutical industry. TM Threaded connection, IDF Typical applications: Life science/pharmaceutical industry. ISO 853 BS85- TM Threaded connection (male), GAZ Typical applications: Food and beverage industry Other industrial products. DIN ISO 8 TM To be sealed with thread tape 3
31 ì Connection selection guide Sanitary pumps Threaded connection (female) DIN EN 16-1 Typical applications: Industrial applications. TM To be sealed with thread tape Description of components Pos. Description 1a Threaded connection in pump housing 1 Threaded connection 11 Circular joint ring 1 O-ring 95 Grooved union nut 31
32 Connection selection guide Sanitary pumps Flanges Connection Standard Design Aseptic flange DIN Typical applications: Life science/pharmaceutical industry. TM Flange, APV-FN1/APV-FG1 ISO Typical applications: Food and beverage industry. TM Flange (fixed flange) Flange, ANSI 15 and 3 LB RF DIN EN 19-1 ANSI Typical applications: Industrial applications. TM Flange (loose flange) DIN EN 19-1 Typical applications: Industrial applications. TM Kremo flange DIN EN 19-1 Typical applications: Industrial applications. TM Description of components Pos. Description 1a Flanged connection in pump housing 1 Flanged connection Gasket 1 Profile gasket 1 O-ring 91 Hexagon head screw 9 Hexagon nut 3
33 Connection selection guide Sanitary pumps Clamps Connection Standard Design Clamp Clamp Clamp Clamp Tri-Clamp /Tri-Clover Typical applications: Life science/pharmaceutical industry. Clamp, ISO and SMS Typical applications: Food industry Life science/pharmaceuticalindustry. Description of components Pos. Description 11a Clamp connection in pump housing 11 Clamp connection 1 Profile gasket 51 Clamp ring DIN 3676 ISO 85 BS 85-3 ASME BPE TM
34 Pipe connections Sanitary pumps Euro-HYGIA Euro-HYGIA I Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 3/5 3/3 /5 /3 / 5/3 5/ 5/5 65/ 65/5 OD 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ / 1¼ / 1½ / ½ / 1½ ½ / a e h e h a e h e h a e h e h a ) e h e h On request a 1 1 5) 1 5) e h e 5 h 3 On request a e h e h a e h e h a e h e h On request Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). ) Dimensions of KLM version. For HPM version, dimension a1 is 8 mm for DNs. 5) Dimensions of KLM version. For HPM version, dimension a1 is 91 mm for DNs 3. Dimensions e 5 and h 3 of vertical version. Discharge branch cannot be completely drained (not eccentric). 3
35 Pipe connections Sanitary pumps Euro-HYGIA II Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/5 65/5 65/65 8/5 8/65 8/8 1/65 1/8 1/1 15/8 15/1 OD / ½ / ½ / ½ 3 / 3 / ½ 3 / 3 / ½ / 3 / 5 / 3 5 / a e h e h a e h e h a e h e h a e h e h 3 On request - - a e h e h 3 On request - - a e h e h a e h e h a e h e h 3 On request - - Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric). 35
36 Pipe connections Sanitary pumps F&B-HYGIA F&B-HYGIA I Connections DIN / 5/5 OD 1½ / 1½ / Threaded a connection DIN e (3A-3A1) h Kremo flange a DIN EN 19-1 (DIN 633/) e PN 1 h (3A) Clamps for a Tri-Clamp Tri-Clover e (3A-3A) h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. F&B-HYGIA II Connections DIN 65/65 8/8 1/1 OD ½ / ½ 3 / 3 / Threaded a connection DIN e (3A-3A1) h Kremo flange a DIN EN 19-1 (DIN 633/) e PN 1 h (3A) Clamps for a Tri-Clamp Tri-Clover e (3A-3A) h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 36
37 Pipe connections Sanitary pumps Contra I Contra I Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/5 3/5 3/3 /3 / 5/5 3/5 3/3 /3 / OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1-Stage -Stage a f h e h a f h e h a f h e h a f h e h a f h e 5 On request On request h 3 a f h e h a f h e h a f h e h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric). 37
38 Pipe connections Sanitary pumps Contra I, continued Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/5 3/5 3/3 /3 / 5/5 3/5 3/3 /3 / OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 3-Stage -Stage a f h e h a f h e h a f h e h a f h e h a f h e 5 On request On request h 3 a f h e h a f h e h a f h e h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric). 38
39 Pipe connections Sanitary pumps Contra I, continued Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/5 3/5 3/3 /3 / 5/5 3/5 3/3 /3 / OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1¼ 1½ / 1½ 5-Stage 6-Stage a f h e h a f h e h a f h e h a f h e h a f h e 5 On request On request h 3 a f h e h a f h e h a f h e h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric). 39
40 Pipe connections Sanitary pumps Contra II Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/ 5/5 65/5 65/65 8/65 5/ 5/5 65/5 65/65 8/65 OD / 1½ / ½ / ½ / ½ 3 / ½ / 1½ / ½ / ½ / ½ 3 / ½ 1-Stage -Stage a f h e h a f h e h a f h e h a f h e h a f h e 5 On request On request h 3 a f h e h a f h e h a On request On request f h e 5 On request On request h 3 Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric).
41 Pipe connections Sanitary pumps Contra II, continued Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/ 5/5 65/5 65/65 8/65 5/ 5/5 65/5 65/65 8/65 OD / 1½ / ½ / ½ / ½ 3 / ½ / 1½ / ½ / ½ / ½ 3 / ½ 3-Stage -Stage a f h e h a f h e h a f h e h a f h e h a f h e 5 On request On request h 3 a f h e h a f h e h a On request 5 16 On request f h e 5 On request On request h 3 Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric). 1
42 Pipe connections Sanitary pumps Contra II, continued Connections Aseptic threaded connection DIN ) (3A-3A3) Threaded connection DIN (3A-3A1) Aseptic flange DIN ) (3A-3A3) Flange APV FN1/FG1 PN 1 (3A-3A1) Flange DIN EN 19-1 (DIN 633) PN 16 (3A) Kremo flange DIN EN ) (DIN 633/) PN 1 (3A) Clamp to DIN 3676 (3A-3A) Clamps for Tri-Clamp Tri-Clover (3A-3A) DIN 5/ 5/5 65/5 65/65 8/65 OD / 1½ / ½ / ½ / ½ 3 / ½ 5-Stage a f h e h a f h e h a f h e h a f h e h a f h e 5 h 3 On request a f h e h a f h e h a On request f h e 5 h 3 On request Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1) Aseptic, threaded connection for pipes to DIN 11866, Row A. ) Aseptic, grooved flange for pipes to DIN 11866, Row A. 3) DNs/DNd - fixed/loose flange (DNs 65 as DIN 6-loose flange). Dimensions e5 and h3 of vertical version. Discharge branch cannot be completely drained (not eccentric).
43 Pipe connections Sanitary pumps durietta Connections Threaded connection DIN (3A-3A1) Threaded connection SMS (3A-3A1) Threaded connection DIN ISO 8 (male) - GAZ (3A) Tapped connection DIN EN 16-1 (female) (3A) Flange DIN EN ) (DIN 6) PN 1 (3A) Clamp to ISO (3A-3A1) Clamp to SMS (3A-3A1) DIN 5/5 3/5 3/3 /5 /3 / 5/5 3/5 3/3 /5 /3 / OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 1-Stage -Stage A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1+) Add.5 mm for pumps with double mechanical seal. 3
44 Pipe connections Sanitary pumps durietta, continued Connections Threaded connection DIN (3A-3A1) Threaded connection SMS (3A-3A1) Threaded connection DIN ISO 8 (male) - GAZ (3A) Tapped connection DIN EN 16-1 (female) (3A) Flange DIN EN ) (DIN 6) PN 1 (3A) Clamp to ISO (3A-3A1) Clamp to SMS (3A-3A1) DIN 5/5 3/5 3/3 /5 /3 / 5/5 3/5 3/3 /5 /3 / OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 3-Stage -Stage A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 1+) Add.5 mm for pumps with double mechanical seal.
45 Pipe connections Sanitary pumps durietta, continued Connections Threaded connection DIN (3A-3A1) Threaded connection SMS (3A-3A1) Threaded connection DIN ISO 8 (male) - GAZ (3A) Tapped connection DIN EN 16-1 (female) (3A) Flange DIN EN ) (DIN 6) PN 1 (3A) Clamp to ISO (3A-3A1) Clamp to SMS (3A-3A1) DIN 5/5 3/5 3/3 /5 /3 / 5/5 3/5 3/3 /5 /3 / OD 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 1 / 1 1¼ / 1 1¼ / 1¼ 1½ / 1 1½ / 1¼ 1½ / 1½ 5-Stage 6-Stage A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K A A' B (1) B' () C J K
46 Pipe connections Sanitary pumps SIPLA For dimensions on connections for SIPLA please see pages
47 Pipe connections Sanitary pumps MAXA MAXA 8-16 Connections DIN 1/8 15/8 15/1 15/8 OD / 3 5 / 3 5 / 6 / 3 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXA 8- Connections DIN 1/8 1/1 15/8 15/1 15/8 15/1 OD / 3 / 5 / 3 5 / 6 / 3 6 / Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXA 8-5 Connections DIN 1/8 1/1 15/8 15/1 15/8 15/1 OD / 3 / 5 / 3 5 / 6 / 3 6 / Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXA Connections DIN 1/8 1/1 15/8 15/1 15/8 15/1 OD / 3 / 5 / 3 5 / 6 / 3 6 / Kremo flange DIN EN 19-1 (DIN 633) (3A) a MAXA 1- Connections DIN 15/1 15/15 15/1 15/15 OD 5 / 5 / 5 6 / 6 / 5 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXA 1-5 Connections DIN 15/1 15/15 15/1 15/15 OD 5 / 5 / 5 6 / 6 / 5 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXA Connections DIN 15/1 15/15 15/1 15/15 OD 5 / 5 / 5 6 / 6 / 5 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 7
48 Pipe connections Sanitary pumps MAXA 15-5 Connections DIN 15/15 15/15 175/15 /15 /15 OD 6 / 5 6 / 6 7 / 5 8 / 5 8 / 6 Flange a DIN EN ) (DIN 63) h (3A) Flange a DIN EN ) (DIN 633) (3A) h MAXA Connections DIN 15/15 /15 OD 6 / 5 8 / 6 Flange a DIN EN ) (DIN 633) (3A) h MAXA 15-5 Connections DIN /15 5/15 5/ OD 8 / 6 1 / 6 1 / 8 Flange a DIN EN ) (DIN 63) h (3A) Flange a DIN EN ) (DIN 633) (3A) h MAXA Connections DIN /15 5/15 5/ OD 8 / 6 1 / 6 1 / 8 Flange a DIN EN ) (DIN 63) h (3A) Flange a DIN EN ) (DIN 633) (3A) h - - MAXA 15- Connections DIN /15 / OD 8 / 6 8 / 8 Flange a DIN EN ) (DIN 63) (3A) h 5 5 MAXA - Connections DIN / 5/ OD 8 / 8 1 / 8 Flange a DIN EN ) (DIN 63) (3A) h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 8
49 Pipe connections Sanitary pumps MAXANA MAXANA 3-16 Connections DIN 5/3 5/ 65/3 65/ OD / 1¼ / 1½ ½ / 1¼ ½ / 1½ Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA 3- Connections DIN /5 5/3 5/ 65/3 65/ 65/5 OD 1½ / 1 / 1¼ / 1½ ½ / 1¼ ½ / 1½ ½ / Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA -16 Connections DIN 65/ 65/5 8/ 8/5 OD ½ / 1½ ½ / 3 / 1½ 3 / Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA - Connections DIN 65/ 65/5 8/ 8/5 OD ½ / 1½ ½ / 3 / 1½ 3 / Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA 5-15 Connections DIN 65/5 65/65 8/5 8/65 OD ½ / ½ / ½ 3 / 3 / ½ Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA 5-16 Connections DIN 65/5 65/65 8/5 8/65 OD ½ / ½ / ½ 3 / 3 / ½ Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA 5- Connections DIN 65/5 65/65 8/5 8/65 OD ½ / ½ / ½ 3 / 3 / ½ Kremo flange a DIN EN 19-1 (DIN 633) (3A) h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 9
50 Pipe connections Sanitary pumps MAXANA Connections DIN 8/65 1/65 8/8 1/8 OD 3 / ½ 3½ / ½ 3 / 3 3½ / 3 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA Connections DIN 8/65 8/8 1/65 1/8 OD 3 / ½ 3 / 3 3½ / ½ 3½ / 3 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA 65- Connections DIN 8/65 8/8 1/65 1/8 OD 3 / ½ 3 / 3 3½ / ½ 3½ / 3 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h MAXANA 65-5 Connections DIN 8/65 8/8 1/65 1/8 OD 3 / ½ 3 / 3 3½ / ½ 3½ / 3 Kremo flange a DIN EN 19-1 (DIN 633) (3A) h Tolerances to DIN EN 735 connection dimensions of centrifugal pumps. 5
51 Construction Sanitary pumps Pumps Please see subsection construction in the individual pump chapters at the beginning of this data booklet. Impellers Grundfos offers four impeller types suitable for different liquids and applications. Not all impeller types are available for the complete product range. The two-channel, closed impeller is suitable for pumped liquids containing solid particles. The standard, closed impeller is suitable for pumped liquids with a low content of solid particles. This impeller type has the highest efficiency. The closed impellers are not fitted in durietta. Free-flow impeller Semi-open impeller GR9393 Fig. 31 Semi-open impeller The electro-polished, stainless steel, semi-open impeller is available in three versions, according to the application. Impeller version Application Surface finish Cast Industrial/hygienic 3A to 3A1 Welded Industrial/hygienic 3A to 3A1 Milled Industrial/hygienic/sterile 3A to 3A3 For surface finish requirements, see page 56. The impeller is suitable for low-viscosity liquids and liquids containing particles. The semi-open impeller is not fitted in durietta. GR939 Fig. 33 Free-flow impeller The electro-polished, stainless steel, free-flow impeller is available in two versions, according to the application. Impeller version Application Surface finish Cast Industrial/hygienic 3A to 3A1 Welded Industrial/hygienic 3A to 3A1 For surface finish requirements, see page 56. The non-clogging, free-flow impeller is designed for pumped liquids with a high content of solid particles or fibres. Star impeller Closed impeller GRA393p Two-channel, closed Fig. 3 Closed impellers Standard, closed Both types of electro-polished, stainless steel, closed impeller are available in two versions, according to the application. GR GR939 Fig. 3 Star impeller The electro-polished, stainless steel, star impeller is available in one version. Impeller version Application Surface finish Cast Industrial/hygienic 3A to 3A1 For surface finish requirements, see page 56. The highly efficient, self-priming star impeller is suitable for pumped liquids with a low content of solid particles. Impeller version Application Surface finish Cast Industrial/hygienic 3A to 3A1 Welded Industrial/hygienic 3A to 3A1 For surface finish requirements, see page
52 Construction Sanitary pumps Surface treatment All non-wetted parts of the pumps have the following surface treatment: 1. Priming colour Epoxy resin (RAL 73) Thickness of film: 5 to 7 µm.. Top coat (standard) Epoxy resin (RAL 51) Thickness of film: 5 to 7 µm. The durietta has a single coat of polyurethane (RAL 51) of a thickness of 3 to µm. Motors The motors are totally enclosed, fan-cooled standard motors with main dimensions to IEC and DIN standards. Electrical tolerances to IEC 3. Mounting designation Pump range Euro-HYGIA Mounting designation to IEC 3-7 Horizontal installation Vertical installation F&B-HYGIA Contra IM 11 (IM B3) IM 111 (IM V5) IM 31 (IM B5) IM 311 (IM V1) SIPLA IM 1 (IM B35) IM 11 (IM V15) MAXA MAXANA durietta IM 1 (IM B35) IM 311 (IM V1) Relative air humidity: Max. 95 % Enclosure class: IP55 Insulation class: F, to IEC 85 Ambient temperature: Max. C (standard motors) Max. 6 C (MG motors, EFF 1). In humid locations, the lowest drain hole in the motor must be opened. In such cases, the motor enclosure class is IP. 5
53 Shaft seals Sanitary pumps Mechanical shaft seal The operating range of the shaft seal depends on the type of shaft seal, the operating pressure and the liquid temperature. The shaft seal types described below are standard seal types; other shaft seal types are available on request. Hygienic applications As standard, Grundfos offers a single shaft seal fitted with a metal spring as seal driver. The seal is suitable for hygienic applications. Fig. 35 Single shaft seal for hygienic applications The single shaft seal has carbon/stainless steel seal faces and EPDM or FKM O-rings. TM Sterile applications As standard, Grundfos offers a closed O-ring seal for sterile applications. Fig. 37 Single shaft seal for sterile applications. The O-ring seal has SiC/SiC seal faces and O-rings of EPDM (optionally FFKM (white) or FKM). p [bar] 3 5 TM p [bar] SiC/SiC/EPDM SiC/SiC/EPDM SiC/SiC/FFKM SiC/SiC/FKM t [ C] TM t [ C] Fig. 36 Operating range of shaft seal with metal spring as seal driver for hygienic applications 1: Carbon/stainless steel + EPDM : Carbon/stainless steel + EPDM and carbon/stainless steel + FKM. TM Fig. 38 Operating range of closed O-ring seal for sterile applications Shaft seals for sanitary pumps Shaft seal Euro-HYGIA F&B-HYGIA Pump range Single Quench Tandem * Back-to-back * Standard On request * Maximum stages Contra durietta SIPLA MAXA MAXANA 53
54 Shaft seals Sanitary pumps Example HILGE 3A 1 19 a e E O 1 Mechanical seal hygienic standard 3A1 3AH 3A Spring design 3A.1 - CrNiMo steel/aisi 3 series 1 Bidirectional 3A1. - CrNiMo steel/aisi 3 series (Ra 3. µm) Direction of rotation, left 3A.1 - CrNiMo steel/aisi 3 series 3 Direction of rotation, right 3A.H1 - Hastelloy Vacuum spring, left 3A1. - CrNiMo steel/aisi 3 series (Ra 3. µm) 5 Vacuum spring, right 3A /AISI 316L (Fe 3 %, Ra 3. µm) 6 Enclosed spring, left 3A.3-1./1.35/AISI 316L (Ra.8 µm) 7 Enclosed spring, right 3A /AISI 316L (Fe 1 %, Ra.8 µm) No additional information necessary 3A.33-1./1.35/AISI 316L (Fe 3 %, Ra.8 µm) Seal design 3A /AISI 316L (Fe 1 %, Ra. µm) A Stationary ring, with twist protection 3A3 3A3.7-1./1.35/AISI 316L (Ra. µm) B Stationary ring, double elastic supported 3A /1.35/AISI 316L (Fe 3 %, Ra. µm) Out of Hilge standard (3A3 / V-gap und Seat for stationary ring C grooves) (L1K always with twist protection) (for WFI only) 1 Mechanical seal seat 1 D Standard dimension N Mechanical seal seat E Standard dimension N, with twist protection 3 Mechanical seal seat 3 F Standard dimension K 7K BS Mechanical seal seat 1 with adjustable screw (durietta back-to-back in contact with liquid) Mechanical seal seat 3,.3 mm (Hygiana/HYGIA old) BS3 Mechanical seal seat 3, mm (Euro-HYGIA ) B1 B Mechanical seal seat B1 (double-elastic supported, bidirectional) Mechanical seal seat B (double-elastic supported, direction of rotation: left) G O T O-rings E/H Standard dimension K, with twist protection No additional information necessary O + sensor for monitoring of temperature (length of sensor 5 mm/ cable m) EPDM, peroxide-crosslinked (with special approvals) G Hypalon K FFKM-FDA (Kalrez ) B3 Mechanical seal seat B3 (double-elastic supported, direction of rotation: right) J FFKM (Kalrez ), USP Class VI 3A Sanitary Standard 18-3 Class I / FDA L1K Standard seal length L1K P NBR (Perbunan ) L1N Standard seal length L1N S Silicone XXX Special seat T PTFE (Teflon ) Shaft diameter at position of stationary ring [mm] V FKM-FDA (Viton ) Material, stationary ring FKM (Viton I ) USP Class VI a Carbon graphite, synthetic resin impregnated 3A Sanitary Standard 18-3 Class I / FDA b Tungsten carbide, shrunk Y No O-rings mounted c Ceramic Material, rotary ring d PTFE, glass-fibre reinforced a Carbon graphite, synthetic resin-impregnated e Stainless steel b Tungsten carbide, shrunk f Carbon graphite, antimony impregnated c Ceramic g Tungsten carbide, soldered d PTFE, glass-fibre reinforced h Tungsten carbide, solid e Stainless steel i Silicon carbide, shrunk f Carbon graphite, antimony impregnated k Silicon carbide, solid g Tungsten carbide, soldered m Silicon carbide, solid, Buka7- h Tungsten carbide, solid n EKasic -PG15, solid i Silicon carbide, shrunk o Silicon carbide, solid, Buka-1 k Silicon carbide, solid s Silicon carbide, shrunk, special m Silicon carbide, solid, Buka7- n EKasic -PG15, solid o Silicon carbide, solid, Buka-1 s Silicon carbide, shrunk, special 5
55 Certification Sanitary pumps EHEDG, QHD and GOST The design, materials used and surface finish are subject to a variety of national and international rules and regulations, such as the EHEDG recommendations, the QHD criteria and the GOST standard. EHEDG Fig. 39 EHEDG symbol The EHEDG (European Hygienic Engineering & Design Group) develops guidelines and test methods for the safe and hygienic processing of food. This ensures the microbiological safety of the end product, for example the pumped medium. The EHEDG symbol is used by manufacturers to indicate compliance with the EHEDG recommendations. QHD Fig. QHD symbol The QHD (Qualified Hygienic Design) is a two-phase testing system for the hygienic design and cleanability of components, machinery and plant for aseptic or sterile applications. This ensures that all surfaces can be cleaned in place (CIP). The QHD symbol is used by manufacturers to indicate compliance with the QHD criteria. EHEDG QHD GOST Fig. 1 GOSTR symbol GOST is the Russian word for "standard", the R (P) stands for Russia. For most products, certification is needed if they wish to sell in Russia. The main products concerned are these: materials in contact with food and human beings industrial equipment for food, chemical, oil and gas, construction and other industries mechanical and electrical goods. Also concerned are consumer products such as foodstuffs, textiles and clothes, cosmetics and perfumery, domestic goods and toys. The certificate can be valid for a one-time-only shipment or for a period of 1 or 3 years. Certificates and approvals Grundfos offers the following certificates and approvals: Hygienic design certificates (certificates guaranteeing compliance with the EHEDG recomendations, QHD criteria and GOST standard). Material certificates (certificates stating material specifications). Performance certificates (test reports guaranteeing and certifying test data of QH, current consumption, speed, curves, etc.). Authorized test by third party (surveyed performance test). ATEX-approved sanitary pumps (according to ATEX Directive 9/9/EC). The certificates must be ordered with the pump. GOSTR_Mark 55
56 Certification Sanitary pumps Surface finish of sanitary pumps In order to meet the demands of the pharmaceutical, food and beverage industries, Grundfos has developed the below surface finish requirements: TM Code Application Material Surface finish 3A.1 Industrial CrNiMo steel 3A1. Hygienic CrNiMo steel Ra 3. μm 3A.3 Sterile 3A1. Pharmaceutical 3A.5 Sterile 3A3.6 Sterile 3A3.7 Sterile 3A.33 Sterile 3A3.37 Sterile DIN EN 1./1.35 (AISI 316L) DIN EN 1.35, Fe 3 % DIN EN 1.35, Fe 1 % DIN EN 1.35, Fe 1 % DIN EN 1./1.35 (AISI 316L) DIN EN 1./1.35 Fe 3 % (AISI 316L) DIN EN 1./1.35 Fe 3 % (AISI 316L) Ra.8 μm Ra 3. μm Ra.8 μm Ra. μm Ra. μm Ra.8 μm Ra. μm Certificate Standard EHEDG test report QHD test report Material specification report Material report with certificate CE declaration of conformity ATEX-approved pump Inspection certificate EN Inspection certificate - Lloyds Register of Shipping (LRS) - Det Norske Veritas (DNV) EN Germanischer Lloyd (GL) - Bureau Veritas (BV) Surface roughness report Sound pressure measuring report EN 1639 Motor test report Standard test report ISO 996 Vibration report Certificate of compliance with the order EN 1..1 Test report - non-specific inspection EN 1.. and testing Report, Cleaned and dried pump Report, Electro-polished pump 56
57 Installation Sanitary pumps Mechanical installation Never install the pump with the motor pointing downwards. Horizontal installation Pumps fitted with motors up to and including kw require a 3 mm clearance behind the motor. See fig.. Pumps fitted with motors of 5.5 kw and up require a 3 mm clearance behind and a 1 metre clearance above the motor to allow the use of lifting equipment. See fig.. TM kw Fig. Installation 3 mm The pumps must be installed in such a way that strain from the pipework is not transferred to the pump housing. When installed outdoors, the motor must be provided with a suitable cover to avoid condensation on the electronic components and to protect pump and motor against the direct effects of the elements kw 1 m Space requirements Vertical installation Pumps fitted with motors up to and including kw require a 3 mm clearance above the motor. See fig. 3. Pumps fitted with motors of 5.5 kw and up require at least a 1 metre clearance above the motor to allow the use of lifting equipment. See fig. 3. Fig. Horizontal installation 3 mm.55- kw kw 3 mm 1 m TM3 11 TM3 115 Fig. 3 Vertical installation 57
58 Installation Sanitary pumps Elimination of noise and vibration In order to achieve optimum operation and minimum noise and vibration, consider vibration dampening of the pump. Generally, always consider this for pumps with motors above 11 kw. Smaller motors, however, may also cause undesirable noise and vibration. Noise and vibration are generated by the rotations in the motor and pump and by the flow in pipes and fittings. The effect on the environment is subjective and depends on correct installation and the state of the remaining system. Foundation Vibration dampening is best achieved by installing the pumps on a plane and rigid concrete foundation. See fig. 5. Expansion joint Concrete foundation Vibration damper Fig. 5 Example of foundation of a Contra II pump As a rule of thumb, the weight of a concrete foundation should be 1.5 times the pump weight. Vibration dampers To prevent the transmission of vibrations to buildings, we recommend that you isolate the pump foundation from building parts by means of vibration dampers. The selection of the right vibration damper requires these data: forces transmitted through the damper motor speed considering speed control, if any required dampening in % (suggested value is 7 %). Which is the right damper varies from installation to installation, and a wrong damper may increase the vibration level. Vibration dampers should therefore be sized by the supplier. TM3 116 Expansion joints If you install the pump on a foundation with vibration dampers, always fit expansion joints on the pump flanges. This is important to prevent the pump from "hanging" in the flanges. Install expansion joints to absorb expansions/contractions in the pipework caused by changing liquid temperature reduce mechanical strains in connection with pressure surges in the pipework isolate mechanical structure-borne noise in the pipework (only rubber bellows expansion joints). Note: Do not install expansion joints to compensate for inaccuracies in the pipework such as centre displacement of flanges. Fit expansion joints at a distance of minimum 1 to 1½ times the nominal flange diameter away from the pump on the suction as well as on the discharge side. This will prevent the development of turbulence in the expansion joints, resulting in better suction conditions and a minimum pressure loss on the discharge side. At high water velocities (> 5 m/s), we recommend you to install larger expansion joints corresponding to the pipework. Expansion joints with limiting rods can be used to minimise the forces caused by the expansion joints. We always recommend expansion joints with limiting rods for flanges larger than DN 1. The pipes should be anchored so that they do not stress the expansion joints and the pump. Follow the supplier s instructions and pass them on to advisers or pipe installers. Terminal box positions The terminal box positions shown in fig. 6 are possible for all pump ranges. 1 o clock 3 o clock 9 o clock Fig. 6 Possible terminal box positions TM
59 Curve charts Sanitary pumps How to read the curve charts H MAXA Hz /159 /166 /173 /18 /187 Pump type and frequency. QH curve for the individual pump with a specific impeller diameter. P [kw] Q [m³/h] /166 /159 /173 /18 /187 The power curve indicates pump input power [P] for the individual pump with a specific impeller diameter. Eta [%] Q [m³/h] /18 /187 The eta curve indicates the pump efficiency for the individual pump with a specific impeller diameter /159 /166 / Q [m³/h] NPSH 8 6 /159 /166 The NPSH curve indicates the Net Positive Suction Head of the individual pump with a specific impeller diameter. /18 /187 / Q [m³/h] Q [l/s] TM
60 Curve charts Sanitary pumps Curve conditions The guidelines below apply to the curves shown on the following pages: 1. Tolerances to ISO 996, Annex A. 1 kw < P < 1 kw Flow rate: ±9 % Total head: ±7 % Efficiency: up to 7 % * * Efficiency of motor sizes below 1 kw are calculated on the basis of a formula stated in ISO 996. P > 1 kw Flow rate: ±8 % Total head: ±5 % Efficiency: 5 %. QH curves of the individual pumps are shown with expected speed of a three-phase standard motor. 3. Measurements have been made with airless water at a temperature of + C.. The curves apply to the following kinematic viscosity: υ = 1 mm /s (1 cst). 5. If the pumped liquid density and/or viscosity is higher than that of water, it may be necessary to use a motor with a higher performance. 6
61 Performance curves/ technical data Euro-HYGIA I 5 Hz Euro-HYGIA I -pole, 9 min -1 Euro-HYGIA I -pole, 15 min -1 H P [kw] Eta [%] Euro-HYGIA I 5 Hz /185 /1 / Q [m³/h] /185 /1 / Q [m³/h] /185 /1 /155 NPSH Q [m³/h].5. H Euro-HYGIA I 5 Hz /185 /13 /155 P Q [m³/h] [kw].8 /185.7 Eta [%] /13 / Q [m³/h] NPSH Q [m³/h].5. /185 /13 / /1 /155 / /13 /185 / Q [m³/h] Q [l/s] TM Q [m³/h] Q [l/s] TM
62 Technical data Euro-HYGIA I 5 Hz Euro-HYGIA I Adapta on cast iron foot Option Housing with clamp ring (KLM) TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size b k (1) 3 u (1) S S L L L L M S 39 5 Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 3. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 6
63 Technical data Euro-HYGIA I 5 Hz Euro-HYGIA I Adapta SUPER on stainless steel combi foot (frame size 8-9) Option Housing with clamp ring (KLM) TM3 38 Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H h H ø d H S S L L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 3. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 63
64 Technical data Euro-HYGIA I 5 Hz Euro-HYGIA I Adapta SUPER on stainless steel combi foot (frame size 1-13) Option Housing with clamp ring (KLM) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H h H ø d H. 15 1L L M S 51 Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 3. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 6
65 Technical data Euro-HYGIA I 5 Hz Euro-HYGIA I Bloc on cast iron foot Option Housing with clamp ring (KLM) TM3 38 Technical data On cast iron foot P [kw] n [min -1 ] IEC size (1) k 3 u (1) S S L L L L M M Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 3. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 65
66 Technical data Euro-HYGIA I 5 Hz Euro-HYGIA I Bloc-SUPER on stainless steel combi foot Option Housing with clamp ring (KLM) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l l H ø d H S S L L L L M M Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 3. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 66
67 Performance curves Euro-HYGIA II 5 Hz Euro-HYGIA II Euro-HYGIA II -pole, 9 min -1 -pole, 15 min -1 H Euro-HYGIA II 5 Hz /3 /1 /19 H Euro-HYGIA II 5 Hz /3 /1 /19 1 P [kw] Q [m³/h] /3 /1 /19 P [kw] Q [m³/h] /3 /1 / Eta [%] Q [m³/h] /3 /1 /19 NPSH Q [m³/h] Eta [%] Q [m³/h] NPSH Q [m³/h] 3. /3 /19 /1 3 1 /3 /19 / /1 /3 / Q [m³/h] Q [l/s] TM Q [m³/h] Q [l/s] TM
68 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Adapta on Adapta foot (frame size 18M) Option Housing with clamp ring (KLM) TM Technical data Su piede Adapta P [kw] n [min -1 ] IEC size (1) k 3 u (1). 9 18M Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 68
69 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Adapta on cast iron foot (frame size 1-16) Option Housing with clamp ring (KLM) TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size b (1) k 3 u (1). 15 1L L L M M S S S M M M L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 69
70 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Adapta SUPER on stainless steel combi foot (frame size 1-16) Option Housing with clamp ring (KLM) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H h H ø d H. 15 1L L L M M S S S M M M L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 7
71 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Adapta SUPER on machine feet (frame size 18) Option Housing with clamp ring (KLM) TM Technical data P [kw] n [min -1 ] IEC size. 9 18M Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 71
72 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Bloc on cast iron foot (frame size 9-13) ø1 5 Option Housing with clamp ring (KLM) 15 5 TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size (1) k 3 u (1) S L S L L L L M M M M M S M Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 7
73 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Bloc on motor foot with stainless steel support (frame size 16) Option Housing with clamp ring (KLM) TM Technical data On motor foot with stainless steel plinth P [kw] n [min -1 ] IEC size (1) k 3 u (1) m 1 m ø s n 1 n M L L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 73
74 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Bloc-SUPER on stainless steel combi foot (frame size 9-13) Option Housing with clamp ring (KLM) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l l H ø d H S L S L L L L M M M M M S M Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 7
75 Technical data Euro-HYGIA II 5 Hz Euro-HYGIA II Bloc-SUPER on stainless steel combi foot (frame size 16) Option Housing with clamp ring (KLM) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l l H ø d H M L L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 35. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (8) Option: Gemü DN 15 diaphragm drain valve. Drain-clamp connection to DIN DN 15 (5 angle). 75
76 Performance curves F&B-HYGIA I 5 Hz F&B-HYGIA I -pole, 9 min -1 H P [kw] Eta [%] F&B-HYGIA I 5 Hz /185 /1 / Q [m³/h] /185 /1 / Q [m³/h] /185 /1 /155 NPSH Q [m³/h].5 F&B-HYGIA I -pole, 15 min -1 H F&B-HYGIA I 5 Hz /185 /13 /155 P Q [m³/h] [kw].8 / Eta [%] /13 / Q [m³/h] NPSH Q [m³/h].5 /185 /13 / /1 / /13 /185 /155.5 / Q [m³/h] Q [l/s] TM Q [m³/h] Q [l/s] TM
77 Technical data F&B-HYGIA I 5 Hz F&B-HYGIA I K on motor foot TM Technical data On motor foot P [kw] n [min -1 ] IEC size k 3 u a m n n 1 s 1 h 1 o S ) S L ). 9 9L ). 15 1L L M S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 77
78 Technical data F&B-HYGIA I 5 Hz F&B-HYGIA I K on cast iron foot TM Technical data 11 On cast iron foot P [kw] n [min -1 ] IEC size k 3 u S ) S L ). 9 9L ). 15 1L L M S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 78
79 Technical data F&B-HYGIA I 5 Hz F&B-HYGIA I K on combi foot TM Technical data 11 On combi foot P [kw] n [min -1 ] IEC size k 3 u S ) S L ). 9 9L ). 15 1L L M S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motors. 79
80 Technical data F&B-HYGIA I 5 Hz F&B-HYGIA I K SUPER on combi foot TM Technical data P [kw] n [min -1 ] IEC size On combi foot l l H h H ø d H S ) 316 1) S L ) 316 1). 9 9L ) 316 1). 15 1L L M S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 8
81 Performance curves F&B-HYGIA II 5 Hz F&B-HYGIA II -pole, 9 min-1 -pole, 15 min -1 H F&B-HYGIA II 5 Hz /3 /1 /19 H F&B-HYGIA II 5 Hz /3 /1 /19 1 P [kw] Q [m³/h] /3 /1 /19 P [kw] Q [m³/h] /3 /1 / Eta [%] Q [m³/h] /3 /1 /19. Eta [%] Q [m³/h] /3 /1 / NPSH Q [m³/h] 5 35 NPSH Q [m³/h] /1 /3 / /1 /3 / Q [m³/h] Q [l/s] TM Q [m³/h] Q [l/s] TM
82 Technical data F&B-HYGIA II 5 Hz F&B-HYGIA II K on motor foot TM Technical data On motor foot P [kw] n [min -1 ] IEC size k 3 u a m n n 1 s 1 h 1 o. 15 1L L L M M S S S M ) M L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. Motors up to 11 kw are Grundfos MG motors. The EFF 1 MG motor is not available as 5.5 kw, -pole. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 15 kw and 18.5 kw are Siemens motors. 8
83 Technical data F&B-HYGIA II 5 Hz F&B-HYGIA II K on cast iron foot TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size k 3 u. 15 1L L L M M S S S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. The EFF 1 MG motor is not available as 5.5 kw, -pole. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 83
84 Technical data F&B-HYGIA II 5 Hz F&B-HYGIA II K on combi foot (frame size 1-13) TM Technical data On combi foot P [kw] n [min -1 ] IEC size k 3 u. 15 1L L M M M S S S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. The EFF 1 MG motor is not available as 5.5 kw, -pole. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 8
85 Technical data F&B-HYGIA II 5 Hz F&B-HYGIA II K on combi foot (frame size 16) TM Technical data 17 On combi foot P [kw] n [min -1 ] IEC size k 3 u M ) M L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page kw is a Grundfos MG motor. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 15 kw and 18.5 kw are Siemens motors. 85
86 Technical data F&B-HYGIA II 5 Hz F&B-HYGIA II K SUPER on combi foot (frame size 1-13) TM Technical data On combi foot P [kw] n [min -1 ] IEC size l l H h H ø d H. 15 1L L L M M S S S Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page 36. All motors are Grundfos MG motors. The EFF 1 MG motor is not available as 5.5 kw, -pole. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 86
87 Technical data F&B-HYGIA II 5 Hz F&B-HYGIA II K SUPER on combi foot (frame size 16) TM Technical data P [kw] n [min -1 ] IEC size On combi foot l l H h H ø d H M ) 56 1) 185 1) 37 1) M L Dimensions depend on housing size (DN s, DN d, a 1, h, e 1 ). See table of connections, page kw is a Grundfos MG motor. 1) Indicates the dimensions of the EFF MG motor when they differ from the dimensions of the EFF 1 MG motor. 15 kw and 18.5 kw are Siemens motors. 87
88 Performance curves Contra I 5 Hz Contra I -pole, 9 min -1 H Contra I 5 Hz P [kw] Eta [%] Q [m³/h] Q [m³/h] NPSH Q [m³/h] Q [m³/h] Q [l/s] TM
89 Technical data Contra I 5 Hz Contra I Adapta on cast iron foot TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size b (1) k 3 u (1) S S L L L L M S 39 5 Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page 37. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) Coupling of our choice. 89
90 Technical data Contra I 5 Hz Contra I Adapta SUPER on stainless steel combi foot (frame size 8-9) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H h H ø d H S S L L Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page 37. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) Coupling of our choice. 9
91 Technical data Contra I 5 Hz Contra I Adapta SUPER on stainless steel combi foot (frame size 1-13) 3 3 TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H h H ø d H. 15 1L L M S 51 Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page 37. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) Coupling of our choice. 91
92 Technical data Contra I 5 Hz Contra I Adapta -V on stainless steel pedestal with/without suction elbow For installing, removing and servicing the pump, lifting points should be provided directly above the pump and removable lengths incorporated into the suction line. TM Technical data On stainless steel pedestal with/without suction elbow P [kw] n [min -1 ] IEC size b k (1) 3 u (1) S S L L L L M S 39 5 Dimensions depend on housing size (DN s, DN d, a 1, e 5, f, h, h 3 ). See table of connections, page 37. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) Coupling of our choice. 9
93 Technical data Contra I 5 Hz Contra I Bloc on cast iron foot TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size (1) k 3 u (1) S S L L L L M M Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page 37. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. 93
94 Technical data Contra I 5 Hz Contra I Bloc-SUPER on stainless steel combi foot TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H ø d H S S L L L L M M 5 7 Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page 37. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. 9
95 Performance curves Contra II 5 Hz Contra II -pole, 9 min -1 H P [kw] Contra II 5 Hz Q [m³/h] Eta [%] Q [m³/h] NPSH Q [m³/h] Q [m³/h] Q [l/s] TM
96 Technical data Contra II 5 Hz Contra II Adapta on cast iron foot TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size b (1) k 3 u (1) L M M S S S M M M L Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. 96
97 Technical data Contra II 5 Hz Contra II Adapta SUPER on stainless steel combi foot (frame size 1-16) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l H h H ø d H L M M S S S M M M L Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. 97
98 Technical data Contra II 5 Hz Contra II Adapta -V on stainless steel pedestal with/without suction elbow (frame size 1-16) 75 For installing, removing and servicing the pump, lifting point should be provided directly above the pump and removable lengths incorporated into the suction line. The discharge port is asymmetric; the pump can be drained completely. TM Technical data On stainless steel pedestal with/without suction elbow P [kw] n [min -1 ] IEC size b k (1) 3 u (1). 15 1L L L M M S S S M M M L Dimensions depend on housing size (DN s, DN d, a 1, f, h, h 3, e 1, e 5 ). See table of connections, page. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. (7) N-Eupex coupling. 98
99 Technical data Contra II 5 Hz Contra II Bloc on cast iron foot (frame size 9-13) TM Technical data On cast iron foot P [kw] n [min -1 ] IEC size (1) k 3 u (1) S S L S L L L L M M M S M Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. 99
100 Technical data Contra II 5 Hz Contra II Bloc-SUPER on stainless steel combi foot (frame size 9-13) TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l l H ø d H S S L S L L L L M M M S M Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. 1
101 Technical data Contra II 5 Hz Contra II Bloc-SUPER on stainless steel combi foot (frame size 16) M1 ø5 TM Technical data On stainless steel combi foot P [kw] n [min -1 ] IEC size l l H ø d H M L Dimensions depend on housing size (DN s, DN d, a 1, f, h ). See table of connections, page. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. 11
102 Performance curves durietta 5 Hz durietta durietta -pole, 9 min -1 -pole, 15 min -1 H 7-6 durietta 5 Hz H.5 durietta 5 Hz P [kw] Q [m³/h] Q [m³/h] Q [l/s] TM P Q [m³/h] [kw] Q [m³/h] Q [l/s] -1 TM
103 Technical data durietta 5 Hz durietta K on motor foot TM Technical data P [kw] n [min -1 ] IEC size Stage h 1 k 3 n m u w 1 Net weight [kg] S S S L L L L Dimensions depend on housing size (DN s, DN d, A, A, B (1), B (), C, J, K). See table of connections, page 3. (1) Add 37.5 mm for pumps with double mechanical seal. 5- and 6-stage pumps are not available with double mechanical seal. 13
104 Technical data durietta 5 Hz durietta K SUPER on stainless steel combi foot TM Technical data P [kw] n [min -1 ] IEC size Stage b H d H h 3 l H m n w L ±5 Net weight [kg] S S S L L L L Dimensions depend on housing size (DN s, DN d, A, A, B (1), B (), C, J, K). See table of connections, page 3. () Add 37.5 mm for pumps with double mechanical seal. 5- and 6-stage pumps are not available with double mechanical seal. 1
105 Performance curves SIPLA 5 Hz SIPLA SIPLA 3.1 and 6.1, -pole, 15 min , 18.1 and 8.1, -pole, 15 min -1 H SIPLA 5 Hz H SIPLA 5 Hz P Q [m³/h] [kw] Eta [%] Q [m³/h] Q [m³/h] NPSH Q [m³/h] Q [l/s] TM P Q [m³/h] [kw]. Eta [%] Q [m³/h] NPSH Q [m³/h] Q [m³/h] 6 8 Q [l/s] TM
106 Performance curves SIPLA 5 Hz SIPLA 5.1, 65.1 and 9.1, -pole, 15 min -1 H 6 SIPLA 5 Hz P [kw] Eta [%] Q [m³/h] Q [m³/h] Q [m³/h] NPSH Q [m³/h] Q [l/s] TM
107 Technical data SIPLA 5 Hz SIPLA Adapta on cast iron foot TM Technical data Pump type DN s /DN d a l Pump Motor On cast iron foot e l 5 l 6 IEC size P [kw] k 3 u Size w 1 m n 1 n s 1 /s h 1 h l M I / / L I / L. 1) I / L II / M. 1) II / S 5.5 1) 37 II / M II / S 5.5 1) 37 II / M 7.5 1) 37 II / M II / M 11. 1) II / ) The pumps are fitted with oversized motors for the pumping of high-viscosity liquids. 17
108 Technical data SIPLA 5 Hz TM Technical data Pump type DN s /DN d a l Pump Motor On cast iron foot e l 5 l 6 IEC size P [kw] k 3 u Size w 1 m n 1 n s 1 /s h 1 h l L III M ) 6 58 III L. 1) 6 58 III M III L. 1) 6 58 III ) The pumps are fitted with oversized motors for the pumping of high-viscosity liquids. 18
109 Technical data SIPLA 5 Hz SIPLA Adapta SUPER on combi foot TM Technical data Pump Motor AD On combi foot Shroud Pump type DN s /DN d a l h 1 h h 3 e l 5 l 6 IEC size P [kw] Size l 7 ' Size m n Size p k 3 ' M.75 I I L 1.5 I I L. 1) I II L 3. II 6 II M. 1) II 6 II S 5.5 1) II 6 II M. II 6 II S 5.5 1) II 6 II M 7.5 1) II 6 II M 7.5 II 6 II M 11. 1) II 5 II ) The pumps are fitted with oversized motors for the pumping of high-viscosity liquids. 19
110 Technical data SIPLA 5 Hz SIPLA Bloc on motor foot TM Technical data Pump type DN s /DN d a l o h Pump Motor e l 5 l 6 IEC size P [kw] h 1 k 3 m n 1 n s 1 w M / L L. 1) L M. 1) S 5.5 1) M S 5.5 1) M 7.5 1) M M 11. 1) L L. 1) L. 1) ) The pumps are fitted with oversized motors for the pumping of high-viscosity liquids. 11
111 Technical data SIPLA 5 Hz SIPLA Bloc-SUPER on stainless steel ball feet TM Technical data Pump type DN s /DN d h 1 h l n m Pump Motor Shroud e l 6 ' a c IEC size P [kw] p k 3 ' M / L L. 1) L M. 1) S 5.5 1) M S 5.5 1) M 7.5 1) M M 11. 1) L L. 1) L. 1) ) The pumps are fitted with oversized motors for the pumping of high-viscosity liquids. 111
112 Performance curves MAXA 5 Hz MAXA 8-16 MAXA pole, 9 min -1 -pole, 15 min -1 H MAXA Hz H MAXA Hz P [kw] Eta [%] /159 /166 /173 /18 / Q [m³/h] /166 /159 /173 /18 / Q [m³/h] /159 /166 /173 /18 /187 NPSH Q [m³/h] 8 6 /159 / P [kw] Eta [%] /18 /173 /166 / Q [m³/h] /166 /18 /173 / Q [m³/h] /18 /173 /166 /187 NPSH Q [m³/h] 6 5 /166 /173 /18 /187 / Q [m³/h] Q [l/s] TM /187 / Q [m³/h] Q [l/s] TM
113 Performance curves MAXA 5 Hz MAXA 8- MAXA 8- -pole, 9 min -1 -pole, 15 min -1 H 7 6 MAXA 8-5 Hz H MAXA 8-5 Hz 5 1 / /18 / /1 / / /8 / /1 /18 /19 / P [kw] Q [m³/h] /8 / /1 / /19 /18 P [kw] Q [m³/h] /19 /18 / /1 /8 / Eta [%] Q [m³/h] /19 /18 /8 / /1 / NPSH Q [m³/h] 6 /8 / 5 Eta [%] Q [m³/h] NPSH Q [m³/h] 6 / 5 /18 / /18 /19 /1 / / /8 /8 3 /1 3 /19 /1 / 1 /18 / Q [m³/h] Q [l/s] TM Q [m³/h] 1 3 Q [l/s] TM
114 Performance curves MAXA 5 Hz MAXA 8-5 MAXA 8-5 -pole, 9 min -1 -pole, 15 min -1 H 11 1 MAXA Hz H 6 MAXA Hz P [kw] / /68 /6 /5 / / Q [m³/h] / /68 /6 /5 / / P [kw] /68 /6 /5 / /3 / Q [m³/h] /68 /6 /5 / /3 / 1 Eta [%] Q [m³/h] / /3 /68 /6 /5 / Eta [%] Q [m³/h] /6 /68 /5 / 5 5 NPSH Q [m³/h] 8 6 /6 / /5 / /68 / Q [m³/h] Q [l/s] TM / /3 NPSH Q [m³/h] /68 /6 /5 / /3 / Q [m³/h] 1 3 Q [l/s] TM
115 Performance curves MAXA 5 Hz MAXA pole, 15 min -1 H MAXA Hz /33 /33 /315 /3 /85 /7 1 P [kw] Eta [%] Q [m³/h] /33 /33 /315 /3 /85 / Q [m³/h] /7 /85 /33 /3 /315 /33 NPSH Q [m³/h] /315 /85 /33 /7 /3 / Q [m³/h] 1 3 Q [l/s] TM
116 Performance curves MAXA 5 Hz MAXA 1- MAXA 1- -pole, 9 min -1 -pole, 15 min -1 H 7 6 MAXA 1-5 Hz H MAXA 1-5 Hz /3 3 1 /15 /195 /5 /185 /3 /5 8 6 /5 /15 /5 /185 /195 P [kw] Q [m³/h] /3 /5 /15 /5 /195 /185 P [kw] Q [m³/h] /3 /5 /15 /5 /195 /185 Eta [%] Q [m³/h] /185 /195 /15 /5 /3 /5 NPSH Q [m³/h] 6 /185 /5 5 /195 /5 /3 Eta [%] Q [m³/h] NPSH Q [m³/h] 6 5 /185 /195 /185 /195 /3 /5 /15 /5 3 1 / Q [m³/h] 6 8 Q [l/s] TM /5 /15 /5 / Q [m³/h] 1 3 Q [l/s] TM
117 Performance curves MAXA 5 Hz MAXA 1-5 MAXA 1-5 -pole, 9 min -1 -pole, 15 min -1 H MAXA Hz H 6 MAXA Hz /67 /55 /5 /35 /5 / /55 /5 /35 /5 /15 /67 P [kw] Q [m³/h] P [kw] Q [m³/h] 8 6 /67 /55 /5 /35 /5 / /55 /5 /35 /5 /15 /67 Eta [%] Q [m³/h] /67 /55 /5 /35 /5 /15 NPSH Q [m³/h] /35 5 /5 /5 /15 /55 /67 3 Eta [%] Q [m³/h] NPSH Q [m³/h] /5 /15 /55 /5 /35 /5 /15 /35 /5 /55 /67 / Q [m³/h] 6 8 Q [l/s] TM Q [m³/h] Q [l/s] TM
118 Performance curves MAXA 5 Hz MAXA 15-5 MAXA pole, 15 min -1 -pole, 15 min -1 H P [kw] MAXA Hz /75 /6 / /3 /5 / Q [m³/h] H P [kw] MAXA Hz /353 /3 /35 /31 / Q [m³/h] 16 1 /75 /9 3 /353 /3 8 /6 /5 /3 / 1 /35 /31 /95 Eta [%] Q [m³/h] /75 /9 Eta [%] Q [m³/h] / /3 /6 / /353 /3 /35 /31 /95 NPSH Q [m³/h] 5 3 / /3 /5 /6 5 NPSH Q [m³/h] 7 / /3 /35 /31 /95 1 /9 / Q [m³/h] 6 Q [l/s] TM Q [m³/h] 6 Q [l/s] TM
119 Performance curves MAXA 5 Hz MAXA 15-5 MAXA pole, 15 min -1 -pole, 15 min -1 H P [kw] MAXA Hz / /65 /8 /5 / Q [m³/h] /65 / /5 /96 /8 H P [kw] MAXA Hz /33 /315 / Q [m³/h] /33 /359 /35 /359 /35 /315 /3 Eta [%] Q [m³/h] / /65 /5 /96 /8 NPSH Q [m³/h] 7 / / /65 /96 / Q [m³/h] Q [l/s] TM Eta [%] Q [m³/h] /33 /315 /3 /359 /35 NPSH Q [m³/h] 7 / /3 /315 /35 / Q [m³/h] Q [l/s] TM
120 Performance curves MAXA 5 Hz MAXA 15- MAXA - -pole, 15 min -1 -pole, 15 min -1 H MAXA 15-5 Hz /38 /36 / / /35 H MAXA - /8 5 Hz /37 /35 / / / P [kw] Q [m³/h] / /38 /36 /3 /35 / P [kw] Q [m³/h] /8 /37 /35 / / Eta [%] Q [m³/h] /36 /3 /35 / / /38 NPSH Q [m³/h] /3 /36 /38 / /35 / Eta [%] Q [m³/h] Q [m³/h] NPSH /8 /37 /35 /35 /37 / / / Q [m³/h] Q [l/s] TM Q [m³/h] Q [l/s] TM
121 Technical data MAXA L 5 Hz MAXA L TM Technical data, -pole Pump size P [kw] IEC size k 3 (1) a 1 f 3 h p 3 p p 5 DN s () DN d () p 6 u (1) w 1 h 1 m 1 m n 1 n h 9 s 1 Net weight [kg] 11 16M M L M M L ( (1) 18M ) L L L L L M L (15) (15) L (1) Motor dimensions depend on make; motor dimensions show maximum size. () Flange dimensions are according to DIN EN 19-1 (DIN 63). Nominal diameters in parentheses are available on request. 11
122 Technical data MAXA L 5 Hz * This drawing applies to pump size 8-16, only. For pump sizes 8- to 15-5, see previous page. TM3 1 1 Technical data, -pole Pump size 8-16* P [kw] IEC size k (1) 3 a 1 f 3 h p 3 p p 5 DN () s DN () d p 6 u (1) w 1 h 1 m 1 m n 1 n h 9 s 1 Net weight [kg] 3 1L M S M S M M ( (1) S ) M M L M L S M S 13M (15) 1 (15) M L M M L () (15) M L (1) Motor dimensions depend on make; motor dimensions show maximum size. () Flange dimensions are according to DIN EN 19-1 (DIN 63). (3) Nominal diameters in parentheses are available on request. (6) Pumps fitted with motors of IEC size 1 and 11 are supported with pump foot and motor foot; from IEC size 13 pumps are fitted with motor foot, only. 1
123 Technical data MAXA CN 5 Hz MAXA CN TM Technical data, -pole Pump size P [kw] IEC size k 3 (1) l 5 E (7) f 1 a 1 h 1 h h 7 ø d ø d DN s () () DN d a l 1 l l 3 b 1 b b 3 d 5 plate Base size Net weight [kg] 11 16M M L M L M L M L ( (1) 37 L ) M L L M M S M L M L L M M S (15) (15) L L M M S M
124 Technical data MAXA CN 5 Hz Technical data, -pole Pump size P [kw] IEC size k 3 (1) l 5 E (7) f 1 a 1 h 1 h h 7 ø d ø d DN s () To be continued on the next page. () DN d a l 1 l l 3 b 1 b b 3 d 5 plate Base size Net weight [kg] 3 1L M L L M S M S ( M (1) 15) M S M M L M L L M S M M (15) (15) S M M L M M L M M 16L () 15 (15) M L L S
125 Technical data MAXA CN 5 Hz Continued from previous page Pump size P [kw] IEC size k 3 (1) l 5 E (7) f 1 a 1 h 1 h h 7 ø d ø d DN s () () DN d a l 1 l l 3 b 1 b b 3 d 5 plate Base size Net weight [kg] 11 16M L M L L L M L L S M M L (5) S M M S M L S M M S M S (1) Motor dimensions depend on make; motor dimensions show maximum size. () Flange dimensions are according to DIN EN 19-1 (DIN 63). (3) Nominal diameters in parentheses are available on request. (7) Coupling of our choice. Larger motors, threaded pipe connections and special flanges are available on request. 15
126 Performance curves MAXANA 5 Hz MAXANA 3-16 MAXANA pole, 9 min -1 -pole, 15 min -1 H MAXANA Hz H MAXANA Hz /18 /17 /16 /15 / /1 /17 /16 /15 /18 P [kw] Q [m³/h] /18 /17 /16 /15 /1 P [kw] Q [m³/h] /1 /17 /16 /15 /18 Eta [%] Q [m³/h] /18 /16 /17 /1 /15. Eta [%] Q [m³/h] /17 /1 /16 /15 /18 3 NPSH Q [m³/h] 8 6 /17 /1 /18 /16 / Q [m³/h] Q [l/s] TM NPSH Q [m³/h] /18 1 /16 /1 /15 / Q [m³/h] Q [l/s] TM
127 Performance curves MAXANA 5 Hz MAXANA 3- MAXANA 3- -pole, 9 min -1 -pole, 15 min -1 H 7 MAXANA 3-5 Hz H 16 MAXANA 3-5 Hz / 1 /1 / 1 3 / /18 /17 6 / /19 /17 /18 / /1 P [kw] Q [m³/h] / /1 / /19 /18 /17 P [kw] Q [m³/h] /18 /17 /19 /1 / /. Eta [%] Q [m³/h] / /1 / /19 /18 /17 NPSH Q [m³/h] 8 6 /18 /19 / /1 /. Eta [%] Q [m³/h] NPSH Q [m³/h] 6 / 5 /17 /19 /18 /19 / / /1 / / /17 /1 / Q [m³/h] Q [l/s] TM Q [m³/h] 6 8 Q [l/s] TM
128 Performance curves MAXANA 5 Hz MAXANA -16 MAXANA -16 -pole, 9 min -1 -pole, 15 min -1 H MAXANA Hz H MAXANA Hz /18 /17 /16 /15 / /1 /15 /17 /18 /16 P [kw] Eta [%] Q [m³/h] /18 /17 /16 /15 / Q [m³/h] /15 /16 /17 /18 /1 NPSH Q [m³/h] P [kw] Eta [%] Q [m³/h] /1 /17 /16 /15 / Q [m³/h] /1 /16 /15 /17 /18 NPSH Q [m³/h] 8 6 /18 /16 /17 /15 3 /15 /17 /1 /16 /18 / Q [m³/h] Q [l/s] TM Q [m³/h] 6 8 Q [l/s] TM
129 Performance curves MAXANA 5 Hz MAXANA - MAXANA - -pole, 9 min -1 -pole, 15 min -1 H P [kw] Eta [%] MAXANA - 5 Hz / /1 / /19 /18 / Q [m³/h] / /1 / /19 /18 / Q [m³/h] /17 /18 /19 / /1 / NPSH Q [m³/h] H P [kw] Eta [%] MAXANA - 5 Hz / /1 / /18 /19 / Q [m³/h] /18 /17 / /1 / / Q [m³/h] /18 /17 / /1 / /19 NPSH Q [m³/h] 8 6 / / /1 8 6 / /1 /19 /18 /17 / /19 /18 / Q [m³/h] Q [l/s] TM Q [m³/h] Q [l/s] TM
130 Performance curves MAXANA 5 Hz MAXANA 5-15 MAXANA pole, 9 min -1 -pole, 15 min -1 H 3 MAXANA Hz H 7 MAXANA Hz P [kw] Eta [%] 7 /115 /15 /15 / Q [m³/h] /115 /15 /15 / Q [m³/h] 3 1 /115 /15 /135 P Q [m³ [kw].7 / Eta [%] 6 /115 /15 / Q [m³ / /115 /15 /15 /135 NPSH Q [m³/h] 8 6 /115 /15 /15 / NPSH Q [m³ /115 /15 /115 /135 /15 /135 /15 / Q [m³/h] Q [l/s] TM Q [m³ Q [ TM
131 Performance curves MAXANA 5 Hz MAXANA 5-16 MAXANA pole, 9 min -1 -pole, 15 min -1 H P [kw] Eta [%] MAXANA Hz /18 /17 /16 /15 / Q [m³/h] /18 /17 /16 /15 / Q [m³/h] /16 /17 /15 /1 /18 NPSH Q [m³/h] 8 6 /16 /17 /18 /15 H MAXANA Hz /1 /16 /15 /17 /18 P Q [m³/h] [kw] 1. / Eta [%] /1 /15 /16 / Q [m³/h] /16 /1 /15 /17 / Q [m³/h] Q [l/s] TM / Q [m³/h] Q [l/s] TM
132 Performance curves MAXANA 5 Hz MAXANA 5- MAXANA 5- -pole, 9 min -1 -pole, 15 min -1 H 7 MAXANA 5-5 Hz H MAXANA 5-5 Hz / /1 / / 3 /19 /18 /17 6 /17 /18 /1 / /19 1 P [kw] Eta [%] Q [m³/h] / /1 / /19 /18 / Q [m³/h] /1 / / /19 /18 /17 NPSH Q [m³/h] P [kw] Eta [%] Q [m³/h] /17 /18 / /19 / / Q [m³/h] /17 /19 /18 / / /1 NPSH Q [m³/h] 8 / / /18 /19 / / Q [m³/h] Q [l/s] TM /19 /18 / / /1 / Q [m³/h] Q [l/s] TM
133 Performance curves MAXANA 5 Hz MAXANA pole, 9 min -1 H 3 MAXANA Hz /155 P [kw] Q [m³/h] 8 /155 6 Eta [%] Q [m³/h] /155 NPSH Q [m³/h] 8 6 / Q [m³/h] 1 3 Q [l/s] TM
134 Performance curves MAXANA 5 Hz MAXANA MAXANA pole, 9 min -1 -pole, 15 min -1 H 5 5 MAXANA Hz H 11 1 MAXANA Hz /1 /18 /17 /16 / /18 /1 /15 /16 /17 P [kw] Eta [%] Q [m³/h] /1 /18 /17 /16 / Q [m³/h] /1 /15 /18 /17 /16 NPSH Q [m³/h] P [kw] Eta [%] Q [m³/h] /1 /15 /16 /18 / Q [m³/h] /1 /18 /15 /16 /17 NPSH Q [m³/h] 8 /18 6 /17 /16 /1 /15 3 / Q [m³/h] 1 3 Q [l/s] TM /18 /15 /1 / Q [m³/h] Q [l/s] TM
135 Performance curves MAXANA 5 Hz MAXANA 65- MAXANA 65- -pole, 9 min -1 -pole, 15 min -1 H 7 6 MAXANA 65-5 Hz H MAXANA 65-5 Hz /17 / /1 / /19 / / / /19 /1 /17 /18 P [kw] Q [m³/h] /17 / /1 / /18 /19 P [kw] Q [m³/h] /17 /19 /18 /1 / / Eta [%] Q [m³/h] / /1 / /19 /18 /17 NPSH Q [m³/h] Eta [%] Q [m³/h] / /17 /1 /18 /19 / NPSH Q [m³/h] /17 /18 /1 /19 / / Q [m³/h] 1 3 Q [l/s] TM /17 /18 /19 / /1 / Q [m³/h] Q [l/s] TM
136 Performance curves MAXANA 5 Hz MAXANA 65-5 MAXANA pole, 9 min -1 -pole, 15 min -1 H MAXANA Hz /68 /55 H MAXANA Hz / /5 / /1 / /5 /55 /68 P [kw] Q [m³/h] /68 /55 / /5 /1 P [kw] Q [m³/h] /1 / /5 /55 /68 Eta [%] Q [m³/h] / Eta [%] Q [m³/h] /55 /68 /5 / /68 /55 / 5 NPSH Q [m³/h] 7 / /68 / /55 / Q [m³/h] 1 3 Q [l/s] TM /1 / Q [m³/h] NPSH / /1 /5 / / Q [m³/h] Q [l/s] TM
137 Technical data MAXANA Adapta 5 Hz MAXANA Adapta on stainless steel foot TM Technical data Pump size P [kw] IEC size k 3 u (1) a 1 h p () b DN () s DN () d Net weight [kg] 3 1L M S L M (65) () S S M M M S S M (5) S M M L M (8) S S S S (65) M M M M M S S S S (1) (8) M M M M Dimensions depend on housing size (DN s, DN d, a 1, h ). See table of connections, page 9. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Flange dimensions are according to DIN EN 19-1 (DIN 63). Nominal diameters in parentheses are available on request. () Largest diameter of pump without motor. (7) N-Eupex coupling. 137
138 Technical data MAXANA Adapta 5 Hz MAXANA Adapta on Adapta foot 1 39 TM Technical data Pump size 65-5 P [kw] n [min -1 ] IEC size b (1) k 3 u (1) M L L L L M (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. (7) N-Eupex coupling. 138
139 Technical data MAXANA Bloc 5 Hz MAXANA Bloc on pump and motor foot TM Technical data, -pole Pump size P [kw] IEC size k 3 (1) u (1) a 1 h 1 h p () m 1 m n 1 n b DN s () DN d () Net weight [kg]. 9L L M M (65) () L M M M M (5) L 11M (8) M (65) M M M (1) (8) M (1) Motor dimensions depend on make; motor dimensions show maximum size. () Other sizes and special connections are available on request. () Largest diameter of pump without motor. 139
140 Technical data MAXANA Bloc 5 Hz Technical data, -pole Pump size P [kw] IEC size (1) k 3 u (1) a 1 h 1 h p () m 1 m n 1 n b () () DN s DN d Net weight [kg] S S (65) () S L S S L (5) S L L S (8) (65) S S L L L (5). 1L L M S S S S L L L (1) (8) L L L M M Dimensions depend on housing size (DN s, DN d, a 1, h ). See table of connections, page 9. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Flange dimensions are according to DIN EN 19-1 (DIN 63). Nominal diameters in parentheses are available on request. () Largest diameter of pump without motor. 1
141 Technical data MAXANA Bloc 5 Hz MAXANA Bloc on motor foot TM Technical data Pump size P [kw] IEC size a 1 h 1 h p m 1 m n 1 n h 9 s () () 1 DN s DN d Net weight [kg] S S (65) () M S S S 13S (5) M L S S (8) S M L (65) S M L L S S S M L L (1) (8) S M L L Dimensions depend on housing size (DN s, DN d, a 1, h ). See table of connections, page 9. (1) Motor dimensions depend on make; motor dimensions show maximum size. () Flange dimensions are according to DIN EN 19-1 (DIN 63). Nominal diameters in parentheses are available on request. () Largest diameter of pump without motor. 11
142 Further product documentation Sanitary pumps WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on WebCAPS contains detailed information on more than 185, Grundfos products in more than languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings. Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures, etc. Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 1
143 1 Further product documentation Sanitary pumps Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download -dimensional (D) and 3- dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: -dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. 13
144 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence Repl GB Subject to alterations. The name Grundfos, the Grundfos logo, and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS A/S. DK-885 Bjerringbro. Denmark Telephone:
Standard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) [email protected]
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
Twin Screw Pump. WANGEN Twin. The hygienic solution for food, cosmetics and chemicals
Twin Screw Pump WANGEN Twin The hygienic solution for food, cosmetics and chemicals Twin screw pump WANGEN Twin With the WANGEN Twin, you can avoid time-consuming cleaning, frequent repairs, excessive
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves
Baumann TM Sanitary and Aseptic Process Valves The Company Fisher Controls International LLC, Baumann Control Valves, is an ISO 9001 certified, PED compliant manufacturer of general utility, precision
2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
extreme applications as standard
grundfos INDUSTRY The insurmountable CR extreme applications as standard THE unsurmountable CR A company you can trust Back in 1971 Grundfos shocked the pump world with the introduction of the CR30 - the
SJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
VM, VMC, VMN. Vertical Multistage Centrifugal Pump, 60Hz
VM, VMC, VMN Vertical Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organisation Swiss Pump Company AG 3645 Thun-Gwatt Switzerland Whole Company Design,
Product Catalogue. ETX, Stainless steel threaded centrifugal pumps, 50 Hz
Product Catalogue ETX, Stainless steel threaded centrifugal pumps, Hz Contents Introduction... ETX... Choosing the right pump There are a wide range of pumps to select from. In order to find the right
RUBBER SLEEVE KNIFE GATE VALVE
RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve
Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY
Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY TYPICAL APPLICATIONS Water supply Transfer and distribution from water systems Pressure boosting in apartment buildings
Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1
Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing
CRK 2-130 A-W-A-BUBV 85805906
GRUNDFOS DATA BOOKLET CRK 2-13 A-W-A-BUBV 858596 Grundfos Pump 497113 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crk2/497113/crk-2-13-13-a-w-a-auuv.html
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: [email protected]
MULTISTAGE CENTRIFUGAL PUMPS
MULTISTAGE CENTRIFUGAL PUMPS MULTISTAGE CENTRIFUGAL PUMPS TK - TKR - VTK - TKK series TK-VTK-TKR-TKK are high pressure multistage pumps. Connection to the driving machine (generally an electrical motor)
CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
How To Pump A Pump
Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller
Questionnaire Pure Media Systems
1. PROJECT INFORMATION: Project Name: Client: Contact Person: Telephone / Fax N : Email: 2. BASIC INFORMATION Type of Pure Media System PW / HPW - Generation PW / HPW - Storage & Distribution System Cold
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
südmo systems for the dairy & food industries
südmo systems for the dairy & food industries fluid process SOLUTIONS systems for the dairy & food industries convincing Solutions! Engineering, Project management, Automation, Valve technology & Assembly
Series description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
CR, CRI, CRN, CRE, CRIE, CRNE
Lenntech [email protected] www.lenntech.com GRUNDFOS DATA BOOKLET CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 5 z CR, CRI, CRN, CRE, CRIE, CRNE Table of contents 1. Product data
Inline Pumps Type NCV / NCVL
Inline Pumps Type NCV / NCVL General The DICKOW-Inline-Pumps, series NCV / NCVL, have been developed for the chemical, petrochemical and related industries. Since the pumps are installed inline, only a
ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to8. 150 PSI : 10 to 24
Type series booklet 8448.1/2-EN--US ISORIA Centered disc butterfly valves with AMRING elastomer liner 240 PSI: 1½ to8 150 PSI : 10 to 24 Design in accordance with ISO 10631 Manual, electrical, pneumatical
SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration
SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration FBSPAKSWASAENc SUPRApak Series SUPRApak S Series Filter Housings Technical Information SUPRApak S series filter housings
Vertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
MTR, MTRE, SPK, MTH, MTA
GRUNDFOS DATA BOOKLET MTR, MTRE, SPK, MTH, MTA Immersible pumps 5/6 Hz MTR, MTRE, SPK, MTH, MTA Table of contents 1. Introduction 3 2. Applications 4 3. Performance range 6 MTR, 5 Hz 6 MTRE, 5 Hz 6 MTR,
Vertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
Mechanical shaft seal types and sealing systems
Chapter 2 Mechanical shaft seal types and sealing systems 1. Mechanical shaft seal types 2. Sealing systems 3. Selecting a mechanical shaft seal Mechanical shaft seal types and sealing systems 1. Mechanical
HORIZONTAL PUMPING SYSTEM
HORIZONTAL PUMPING SYSTEM BORETS U.S. INC. PERFORMANCE TECHNOLOGY INNOVATION Horizontal Pumping System What is HPS? HPS classification, Pumps, Stages, Impellers, Curves/Performance, Components Why use
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
VERTICAL TURBINE AND PROPELLER PUMPS
VERTICAL TURBINE AND PROPELLER PUMPS INTRODUCTION Vertical Turbine and Propeller Pumps Model 7000 Series Turbine Pump Model 800 Series Axial Flow Propeller Pump Model 800 Series Mixed Flow Propeller Pump
SUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications
SUPER-TITAN Split-case pumps with power, performance and reliability for a world of applications The Prestige. The Performance. SUPER-TITAN PUMPS Features The TKL Super-Titan pump makes a significant contribution
SIGMA GROUP a. s. Divize průmyslová čerpadla
SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420
Overview of the. measurement and control technology range
Overview of the measurement and control technology range precise innovative Precision - Made in Germany Schubert & Salzer Control Systems GmbH is a medium-sized company in the Schubert & Salzer Group with
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.
Oil & Gas CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition. 2 Introduction CHTR Reliable delivery at high pressure. Day in and day out, KSB pumps prove their worth again
Flygt N-Pumps 3085, 3102 & 3127. For reliable and efficient wastewater handling
Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life
Bypass level indicator With magnetic display Model BNA
Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height
Vogel - Multistage Pumps Design MP, MPA, MPB, MPV Sizes DN 40 - DN 125
Vogel Pumpen Vogel - Multistage Pumps Design MP, MPA, MPB, MPV Sizes DN 40 - DN 125 1 Performance range: Capacities up to 340 m 3 /h (1500 USgpm) Head up to 500 m (1640 feet) Max. speed up to 3600 min
An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps
An SPX Process Equipment Operation Universal II Industrial Series Rotary Positive Displacement ECP Pumps New levels of performance. Reduced operational and maintenance costs. For more than half a century,
No compromise. Highest total efficiency wastewater pumping. grundfos se & sl ranges Submersible and dry-installed wastewater pumps
grundfos se & sl ranges Submersible and dry-installed wastewater pumps 0.9-30 kw 2, 4, 6 pole 50Hz No compromise Highest total efficiency wastewater pumping ULTIMATE WASTEWATER PUMPING TECHNOLOGY The renewed
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
The conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
O-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
ROTARY PISTON PUMPS THE FEED PUMP TYPE SKK. The variants of the feed pump SKK. Range of pumping liquids (extr.) Reference technical data.
ROTARY PISTON PUMPS THE FEED PUMP TYPE The variants of the feed pump Type rotation-independent safe to run dry (no metal contact) sturdy construction with one-sided bearing power transmission gears in
JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
Series description: Wilo-Yonos MAXO-D
ATAC Solutions LTD / 1 / Series description: 1 /,5-1 1 5/,5-1 3/,5-7 3 3 5/ /, / 11 5-,5-,5-9 Design Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power
Series description: Wilo-Star-Z
H[m] Series description: Wilo-Star-Z 4 3 Wilo-Star-Z Star-Z 2/5 2/4 2 1 Star St ar- Z1 5T Design Glandless circulation pump with threaded connection Application Potable water circulation systems in industry
Plant components, selected for sound performance
Plant components, selected for sound performance Selected plant components to meet our customers demands We provide a wide range of plant components offering lowest cost of ownership, high product safety
Series description: Wilo-Yonos MAXO
16 88 / Series description: Wilo-Yonos MAXO /,5-1 1 Wilo-Yonos MAXO 1 5/,5-1 8 6 /,5-5/3/,5-7 5/3/,5-1 /5/,5-8 65/,5-9 5/,5-9 5/3/,5-1 5 1 15 5 Design Glandless circulation pump with threaded connection
SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS 426 2.98 16.05
SIGMA PUMPY HRANICE SELF PRIMING PUMPS SVA SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +40 581 661 111, fax: +40 581 60 587 Email: [email protected] 46.98 16.05 Applications
RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS 426 2.98 23.01
SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS RPT SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +4 581 661 111, fax: +4 581 602 587 Email: [email protected] 426
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 [email protected] www.viflow.fi
ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS 426 1.99 21.04
SIGMA UMY HRANICE GEAR UMS SIGMA UMY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: [email protected], 426 1.99 21.04 Application In
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
GRUNDFOS INDUSTRY. Grundfos Immersible Pumps
GRUNDFOS INDUSTRY Grundfos immersible pumps a complete and versatile range Universal flange connctions DIN JEM ANSI JIS Plug connector (Harting) () () Suitable for a variety of industrial applications
LC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
DOUBLE GATE KNIFE GATE VALVE
DOUBLE GATE KNIFE GATE VALVE The model knife gate is a bi-directional valve widely used in the Pulp and Paper industry (recycling or secondary fibre processing) designed to handle high concentrated or
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
Grundfos solar surface pump
GRUNDFOS DATA BOOKLET Grundfos solar surface pump Renewable energy-based water supply systems Grundfos solar surface pump Table of contents 1. MGFlex motor 3 Features and benefits 3 Nameplate 3 Connection
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
dp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
SanStar Series SSi and SSO Mixers SANITARY MIXERS
SanStar Series SSi and SSO Mixers SANITARY MIXERS A World Leader In Industrial Mixing Since 1923. Lightnin has 90 years of unrivaled experience in industrial mixing technology, process knowledge, and technological
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Tyco PremiAir Pneumatic Actuators
A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either
durable performance horizontal basket Centrifuges
durable performance horizontal basket Centrifuges Ferrum Ltd. Centrifuge Technology Industriestrasse 11 CH-5503 Schafisheim Switzerland T +41 62 889 14 11 F +41 62 889 15 13 [email protected] www.ferrum.net
Guth Portable gitators R The long-term solution pplications Guth Portable gitators R are used for the mixing, stirring and the homogenization of water-like or medium viscosity products. They are most often
Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE
Owner s Manual Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE WARNING!! Installation & Operating Instructions Self-Priming Centrifugal Pump DO NOT
HOPPER SHAPE KNIFE GATE VALVE
HOPPER SHAPE KNIFE GATE VALVE The model knife gate is a uni-directional wafer valve designed for industrial bulk handling service applications (powdered and granular products). The special design of the
Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
kymanual or Automatic - it s your Choice
. kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.
IN series. Centrifugal pumps standardized to DIN-24255
IN series Centrifugal pumps standardized to DIN-24255 DESCRIPTION The new standardized IN series are single-stage horizontal centrifugal pumps, with axial suction and radial discharge, buit to Standard
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
