Green Building- Innovative Technologies
|
|
|
- Nancy Williams
- 10 years ago
- Views:
Transcription
1 Green Building- Innovative Technologies
2 This document and its content in entirety is confidential, proprietary to and the intellectual property of Wipro EcoEnergy. It cannot be in full or in part shared with or copied by any third party in any form without prior & written permission from Wipro EcoEnergy.
3 Setting the context
4 Wipro Ltd - Confidential The four models for reducing GHG emissions Energy Efficiency Reduce demand for energy Cleaner conventional ( FF) energy Replace FF energy* with Renewable Energy Reduced GHG emissions Sustainable Land-use ( Afforestation, reduced deforestation..)
5 Wipro Ltd - Confidential Sustainable habitat - multiple dimensions of Sustainability Green Buildings Cooling efficiency Earth Air tunnels, Geothermal, Chilled Beams etc Lighting efficiency - LED lighting, Green Transportation More efficient IC engines Lighter materials for car body resulting in higher efficiencies Green Grids Smart grid management resulting in reduced T&D losses Green ICT Hardware virtualization resulting in greater information processing per cycle More energy efficient PCs, Servers and Routers Green Industry More efficient industrial motors & pumps Improved production processes e.g. Smelt reduction in steel industry Waste to heat recovery in industrial processes Green homes Energy efficient home appliances e.g, Energy Star ACs, refrigerators, PCs etc
6 Options for change technological and behavioural Emission reduction Renewables A further shift Bio-products Carbon capture to natural gas and storage Nuclear power Energy conservation and efficiency Mass transportation Road transport Buildings Low energy appliances Doing things differently
7 Building related
8 Building Sustainability Factors impacting sustainability Effective Use of soil & Landscapes Efficient Use of Water Energy Efficient & Eco Friendly Equipment Effective Control & Building Management Systems Use of Renewable Energy Use of Recycled/Recyclable Materials Improved indoor air quality for health and comfort Benefits Reduces energy and water consumption Reduces ecological footprint Improves quality of workspace Wipro has set up the largest number of green facilities in India Wipro Gurgaon The Highest rated LEED Platinum facility outside the US Wipro Ltd - Confidential
9 Indian Complexity Five climate zones 1. Composite (Delhi) 2. Hot Dry (Ahmadabad) 3. Hot Humid (Kolkata), 4. Moderate (Bangalore) 5. Cold (Shillong) Wide variation in climate within each location Requires customised solutions Wipro Ltd - Confidential
10 Building Design Daylight Modeling Daylight simulation coupled with window location/design to minimise lighting load Interiors designed to keep high lighting-load areas close to daylight span Window design to include light shelves Wipro Ltd - Confidential
11 Building Design Shade Analysis Reduces glare without loss of sunlight. Improves thermal performance Full Building Facade Individual Window Wipro Ltd - Confidential
12 Building Design Heat Good energy modeling reduces heat transfer coefficient by upto 40%, and building energy consumption by 6%. Examples: East and west walls with sandwich insulation and air gap Restrict glazing to north and south facades Window to wall ratio < 40% Wipro Ltd - Confidential
13 Building Design strategies To improve indoor air quality to ASHRAE (< 530 ppm): Couple naturally ventilated areas with CO2 sensors Use low VOC paints sealants and adhesives. E.g.: carbon compounds < 250 gms/litre for anti-corrosive paints Laminates used for interior should be free from urea formaldehyde Use of low-flow flush, urinals and closets All electrical and ventilation system to be coordinated with building management system (BMS). Water consumption could also be metered through BMS Landscaping integrated with building design and plant processes: Construction of swales and ponds for water collection which could be used for tertiary treatment Reuse of ETP treated water up to tertiary level for flushing and landscaping Use low water-intensive plants; especially reduce lawn area Use drip sprinklers to reduce evaporation loss Choose native plants; they are most likely to survive with minimal care Wipro Ltd - Confidential
14 Building Materials Roof Insulate composite slab roof with 75mm extruded polystyrene. Reduces heat transmission by 50% Truss insulation of PEB ceiling with 75mm rockwool Roof finish with high reflexive material; SRI > 78. Reduces heat transmission by 10% Wipro Ltd - Confidential
15 TRHS TRHS Building Materials Walls & Windows Use AAC or cellular concrete blocks ( btu) to reduce U-factor Better material can reduce heat gain from walls by 35% Clear Glass Low-E Glass External Louvers with Low-E glass 0.0 Jan Feb Mar Apr May June July Aug Sep Oct Nov DEC Note: Total heat gain from the windows from 9am-7pm throught the year (sat & sunday holiday)- Tonne hrs Improved (TRHS) Proposed (TRHS) 0.00 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Note:Total heat gain from all the walls (TRHS), Sat & Sun hoilday, 9am-7pm (TRHS: Tonne hrs) Use of low-e glass with double glazed windows E.g.: 6mm glass + 12mm airgap + 6mm ecologic (ST150, light blue gray, U factor of 0.33 btu) has 21% reflectance 39% transmittance Reduces heat gain by 15-20% Wipro Ltd - Confidential
16 Green Materials: The choice of a green material depends on following parameters: 1. Physical suitability: Its physical properties like compressive strength, tensile strength, water resistance etc. 2. Dependability: Its dependability on other materials for its aesthetic or functional efficiency. 3. Cost: Affordability subject to the budgetary constraints. 4. Aesthetics: Its aesthetic blend with the entire schema of things 5. Workability: Ease with which it can be used
17 Green Materials: 6. Environmental performance: Embodied energy Recycled content Recyclability Toxic Emissions (if any) Carbon footprint Water footprint Life cycle Impact
18 Other area of applications
19 Data Centre s A data center is said to be efficient when its POWER UTILIZATION EFFECTIVENESS (PUE) is lower. In a data center, air conditioning is the most energy consuming parameter. Efficient design of air conditioning would bring down the overall power consumption on the services. The other levers to enhance the energy efficiency includes better passive shell design, design of IT infrastructure, efficient design and better equipment selection related to UPS, DG and lighting
20 Data Centre s Quick start centrifugal chillers with VFD thus eliminating the need of DX PAC units during power change over. Real time energy simulation, efficient air flow management by using containment strategy, EC fans for the PAC units. Efficient design of controls by mapping the chillers operating curve and integrating the same with building load profile and ambient temperature profile. Efficient pumping system design Primary variable pumping system, Vertical pumps etc. Integrating Pre cooling and free cooling technologies to reduce the OPEX. Minimizing the transmission loss on the electrical side by efficient design.
21 Technology approach to Data Center energy efficiency Wipro Ltd - Confidential
22 Saving approach thru technology application- Closed Loop Cooling system Cooling based on sensing the heat at the back of the racks, active tile sensing the heat to provide needed CFM, and pressure sensors under the floor giving feed back to PAC to deliver needed CFM. Variable CFM through electronically commuted motor and backward curved fans. Thermal modeling and CFD will be used to optimize air flow Power consumption based on the dynamic heat load. Air tunnel pre cooling of incoming fresh air to chiller based on geothermal technology to improve saving. Savings Saving in excess of at least 20% in the power consumption. Hence the original and revised power consumption across the stages would be (in KVA) Standard Adaptive cooling cooling Stage Stage Stage Stage Hence, power consumption schedule would give a saving of Rs. 178 million over a period of 5 years
23 A first in India EE and RE systems used in LEED certified DC For DataCentre - complete green solution Green System implemented : 1. 80TR Geothermal + Earth air tunnel 2. Rainwater Harvesting LPD Solar Thermal ETC water heating system 4. Energy modeling 5. LED/CFL Lighting solution 6. LEED Certification DataCentre Technically reliable, Industrial scale, Financially prudent Green Energy & Cooling Solutions Green IT Complete Green DC Green Lighting Customer IRR of 17-22% Green Building Wipro Ltd - Confidential
24 Innovative Cooling solutions Earth Air tunnel Heat rejected to ground where the temp. is relatively constant round the year Can be used with contrasting climatic conditions in various seasons of a year Used to precool / preheat the air Wipro has adopted innovative cooling solutions in most of the projects.
25 Comfort cooling in a factory environment Energy efficient and eco friendly High enthalpy reduction in the First stage closed Heat exchanger where water is passed resulting no humidity this air air cooling to 28deg C; 2 nd stage further reduces air with direct wter contact to 24 deg C bring within comfort cooling zone. Although the humidity will be around % during pre and post monsoon period, it would not lead to greater discomfort when the space temperature is around C. When compared with Air conditioning system less operating and maintenance cos Better indoor air quality and work environment. Very low CO2 levels.
26 Innovative cooling solutions Geothermal Cooling Heat rejected to ground where the temp. is relatively constant round the year Can be used with contrasting climatic conditions in various seasons of a year Efficiency achieved is as high as 20 ERR. Useful for smaller cooling / heating requirements.
27 Chilled Beams results energy saving It is a type of passive cooling system Major difference between conventional cooling and chilled beam system is chilled beam handles SENSIBLE and LATENT loads separately where as in conventional cooling both are handled simultaneously. Fresh air (SENSIBLE load ) is handled separately and passed into the chilled beams. This induces convection which makes the room air pass through the chilled beam coil and back to the conditioned space, hence cooling the conditioned space. No fan for air circulation, water temp at 12 deg, flow rate lower LATENT load is handled thru separate fresh air handling.
28 Energy savings and merits of chilled beam system Fan Energy Savings No huge air handling units Chiller energy Savings Increase in chilled water set point temperature, hence lower chiller power consumption Heating Energy Savings Excellent Indoor Air Quality and Odor Control Pre treated fresh air through dedicated air handling units Excellent Air Movement and Uniform Air Temperatures No hot and cold spots as the air distribution is uniform Space Savings No AHU room required Very Low Noise Levels Passive cooling
29 Simple payback calculation Sl. No Description Proposal 1 Conventional Proposal 2 - Chilled beams A Parameters 1 Capacity of plant - TR x 230 TR chiller + 1 x 70 TR 1 x 300 TR 2 Plant Configuration Brine chiller 3 Energy Source Electrical Electrical 4 Electrical Load - KW KVA Cost of electrical power - Rs/KWH Capital cost Rs. In Lakhs Differential in capital cost - 7 Rs in Lakhs 65 B Operational cost Saving in Energy cost / 1 Annum - Rs in Lakhs 2 Saving in first year 3 Pay back period - Year
30 Radiant Heating and Cooling CONCRETE CORE TEMPERING Using the Structural System Concrete Core tempering is a new energy efficient way to build which has flywheel effect in case of load/supply variations. Reduce your operating costs by approx. 6-12% Possible use of alternative energy sources The system would require a small AC system to remove peak loads, dehumidify the air (to avoid condensation) and to supply fresh air. The main cooling load is covered by concrete core tempering system, allowing for reduced air exchange rates, AHU s, ducts and fans.
31 Radiant Heating and Cooling UNDER FLOOR HEATING It can used either for a new build or a retrofit and can be made to suit almost any floor type. The method circulates warm water through a closed loop where the water is reused. It provides quite comfort with uniform distribution of warmth. Heating via radiant energy avoiding dryness associated with conventional heating systems. One can choose an energy source to heat the water like gas, solar, heat pump, geothermal. Maximize performance with optimal control through room thermostats with integrated timer s
32 Radiant Heating and Cooling Radiant Panel Heating and Cooling Aesthetically beautiful with acoustic properties enhances radiant cooling systems can be used for new builds or existing structures. Use of drywall panels to activate vertical and horizontal surfaces. Save upto 30% in heating and cooling energy usage. Hygienic, safe and easy to maintain.
33 Thank you Visit:
Siemens Gebze Location FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD
FIRST GREEN BUILDING IN TURKEY CERTIFICIED AS LEED GOLD Slide 1 Energy Efficiency Workshop with KFW & TSKB Sep 28th, 2010 The LEED Green Building Rating System is a voluntary standard that defines high
Subtropical Cities September 2006. Design for Energy Efficiency in Commercial Buildings in Queensland
Subtropical Cities September 2006 Design for Energy Efficiency in Commercial Buildings in Queensland Contents Typical Building Constraints & Requirements Understanding Energy Consumption in Buildings HVAC
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
Green House, Hungary
Further information Skanska AB www.skanska.com Contact Noel Morrin, SVP Sustainability & Green Support [email protected] Green House, Hungary Case Study 109 Aspects of Sustainability This project
FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST
FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST Guruprakash Sastry, Senior Manager Green Initiatives Infosys Limited, Bangalore, INDIA ABSTRACT Radiation
Energy Efficiency: Integrated Design and HVAC Systems HEALTHCARE - TOP 5 GREEN BUILDING STRATEGIES
EPA Publication 909-F-07-001 What? Energy use in healthcare facilities is higher than nearly all other building types. With rising energy costs and climate change concerns energy efficiency is financially
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015
I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 8, Loughborough University, 29 th June 2015 Topics to be considered 1. Progress on project tasks 2. Development of data centre test facility
How To Design A Building In New Delhi
ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption
Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres
What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy
Sino-Italian Environment & Energy Building S I E E B
MOST Ministry of Science and Technology Republic of China Sino-Italian Environment & Energy Building S I E E B Concept The Sino-Italy Environment & Energy Building (SIEEB) is an intelligent, ecological
Sea Water Heat Pump Project
Sea Water Heat Pump Project Alaska SeaLife Center, Seward, AK Presenter: Andy Baker, PE, YourCleanEnergy LLC Also Present is ASLC Operations Manager: Darryl Schaefermeyer ACEP Rural Energy Conference Forum
Building Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
Sustainable Features. High-performance HVAC. High-performance Envelope Green Roof Day-Lighting Bicycle Infrastructure
Sustainable Features High-performance HVAC High-performance Envelope Green Roof Day-Lighting Bicycle Infrastructure Sustainable Landscaping Recycled and Regional Materials Storm-water Management District
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP
research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
Air Conditioning, Comfort and Energy in India s Commercial Building Sector
Air Conditioning, Comfort and Energy in India s Commercial Building Sector THINK.CHANGE.DO Leena Thomas Richard dedear Rajan Rawal Ashok Lall PC Thomas University of Technology, Sydney Sydney University
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
University of St Andrews. Energy Efficient Data Centre Cooling
Energy Efficient Data Centre Cooling St. Andrews and Elsewhere Richard Lumb Consultant Engineer Future-Tech Energy Efficient Data Centre Cooling There is no one single best cooling solution for all Data
Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
Our Triple Bottom Line...
Our Triple Bottom Line... A Better Approach We embrace what we consider to be our responsibility as developers to balance profits with environmental and social dividends. We believe that our long-term
The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
Case Studies: Infrared Heating in Industrial Applications
Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the
CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS
CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS by Dr. Bing Chen and Prof. John Bonsell Passive Solar Research Group University of Nebraska-Lincoln Omaha campus and Richard
DataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
CO2 Emissions. Indirect CO 2. Emissions Electricity and Heat Production 25 % Direct Emissions AFOLU 24 % Energy 1,4% Buildings 6,4 % Industry 11 %
CO2 Emissions Direct Emissions AFOLU 24 % Buildings 6,4 % Transport 14 % 49 Gt CO2 eq (2010) Indirect CO 2 Emissions Electricity and Heat Production 25 % Energy 1,4% Industry 11 % Transport 0,3 % Industry
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings J A NUARY 2015 INTRODUCTION This Research Report explores best practices and approaches for reducing greenhouse gas (GHG)
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
Energy Efficient HVAC-system and Building Design
Energy Efficient HVAC-system and Building Design Maija Virta 1, Harri Itkonen 1, Panu Mustakallio 1, Risto Kosonen 1 1 Halton Oy, Finland Corresponding email: [email protected] SUMMARY This paper
Analysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
Heating & Cooling Efficiency
Heating & Cooling Efficiency Advantages of Geothermal HVAC Efficiency Keith Swilley Gulf Power Company Why Gulf Power Promotes Energy Efficiency? Customer Satisfaction Education Help Customers Make Smart
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
How to Build a Data Centre Cooling Budget. Ian Cathcart
How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options
BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0
BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 To achieve GREEN MARK Award Pre-requisite Requirement All relevant pre-requisite requirements for the specific Green Mark Rating are to be complied
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Adaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics
Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics A Presentation of Work in Progress 4 October 2006 in the Intelligent
Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *
Study on the performance of air conditioning system combining heat pipe and vapor compression based on ground source energy-bus for commercial buildings in north China Yijun Gao, Wei Wu, Zongwei Han, Xianting
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study
Sustainable Strategies for Rehabilitation Projects: 9th Street Office Building Adaptive Reuse Case Study Robert C. Burns, AIA, LEED AP Principal Director of Historic Architecture 804. 648. 5040, ext. 1107
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008 Contents Welcome and Introduction Chapter 1: Data centre energy recap Chapter 2: Co-generation Chapter 3: CTC case study
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
Solar Energy Utilisation in Buildings
Solar Energy Utilisation in Buildings P. Karava, PhD Assistant professor Department of Civil and Environmental Engineering University of Western Ontario 2 Modern Buildings Change in architectural style
Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie
Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Mukesh Khattar, Energy Director, Oracle National Energy Efficiency Technology Summit, Sep. 26, 2012, Portland, OR Agenda
Green Architecture and Construction
Green Architecture and Construction Prof. Dr. Soontorn Boonyatikarn Center of Excellence Building and Environmental Technology, Department of Architecture, School of Architecture, Chulalongkorn University,
Answers to Your Questions from the Webinar
2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS
THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS James L. Hoff, VP of Research Center for Environmental Innovation in Roofing Tools and Models Tools require models
Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.
In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
Case Study. Commercial Building Energy Efficiency Retrofit 4 Mort Street, Canberra. Results. Background PEOPLE PRACTICES SYSTEMS
Case Study PEOPLE PRACTICES SYSTEMS Commercial Building Energy Efficiency Retrofit 4 Mort Street, Canberra In 2010, 4 Mort St, Canberra (Figure 1) was upgraded to significantly improve its energy performance.
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004
Each icon on this map represents the physical location of a station.
ABBOTSFORD SCHOOL DISTRICT: GREEN TOUR TOMORROW S SUSTAINABLE SOLUTIONS TODAY Welcome to the Abbotsford School District: Green Tour. Our goal is to create an interactive learning experience for visitors
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
Rainwater Harvesting
Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
Defining Quality. Building Comfort. Precision. Air Conditioning
Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
Legacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings
Advanced Energy Design Guide LEED Strategies for Schools and High Performance Buildings Today s Presenters Stephen Koontz, LEED AP Energy Services Leader Tampa Bay Trane Allen Irvine General Sales Manager
Solar Cooling. Methods and Applications. Sargon Ishaya, PE, LEED AP
Solar Cooling Methods and Applications Sargon Ishaya, PE, LEED AP Objectives Describe two practical methods for solar cooling Give air conditioning engineers the confidence to offer customers a mechanical
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
Roadmap for Enhancing Energy Efficiency in New Buildings
Roadmap for Enhancing Energy Efficiency in New Buildings Shabnam Bassi Bureau of Energy Efficiency Government of India Page 1 of 33 ENERGY CONSERVATION ACT, 2001 Energy Conservation Act, enacted in October
ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS
ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS By: T. S. Wan Date: April 19, 1994 (1st draft 3/7/86) Copyright 1994 by T. S. Wan (All rights reserved) ABSTRACT: The technology of energy
HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget
A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable
Moisture Content in Insulated Basement Walls
Moisture Content in Insulated Basement Walls Peter Blom,PhD, SINTEF Building and Infrastructure; [email protected], www.sintef.no/byggforsk Sverre B. Holøs M.Sc. SINTEF Building and Infrastructure;
SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight
100% outside air intake Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight Smoke evacuation Natural convection exhaust Atrium skylight Phase change material
Residential Windows, 3 rd edition Corrected index 1
Residential Windows, 3 rd edition Corrected index 1 A absorptance definition, 78 determinants of, 78 79 energy performance and, 78 tinted glass, 84 acoustical properties of windows, 60 61 acrylic glazing
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
Fläkt Woods Building Future
Energy, Expertise and Environment with Fläkt Woods Fläkt Woods Building Future Saving energy in building ventilation You must save 20% on energy before 2020. Following the Kyoto protocol the European Union
Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone. www.titus-hvac.com
Chilled Beam Solutions ADVANCING THE SCIENCE OF AIR DISTRIBUTION k-12 education Redefine your comfort zone. www.titus-hvac.com woodgrains dual-function energy solutions table of contents The CBAL-24 is
Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates
Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates Arthur Rosenfeld, California Energy Commission Gregory Rosenquist, Lawrence Berkeley National Laboratory C. Keith Rice,
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.
Energy Efficient Data Centre at Imperial College M. Okan Kibaroglu IT Production Services Manager Imperial College London 3 March 2009 Contents Recognising the Wider Issue Role of IT / Actions at Imperial
HVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,
Molds and mildew are fungi that grow
Appendix C: Moisture, Mold and Mildew Molds and mildew are fungi that grow on the surfaces of objects, within pores, and in deteriorated materials. They can cause discoloration and odor problems, deteriorate
Continuous Energy Management at UC San Diego. Anna Levitt, P.E. Assistant Energy Manager June 13, 2013
Continuous Energy Management at UC San Diego Anna Levitt, P.E. Assistant Energy Manager June 13, 2013 UC San Diego: A 42 megawatt Microgrid With a daily population of over 45,000, UC San Diego is the size
Energy Efficiency. Bars & RestauRants. www.energia.ie
Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could
Sika Sarnafil World Class Roofing and Waterproofing
The following is a brief summary of the Leadership in Energy and Environmental Design program (LEED, Version 3) and the sections Sika Sarnafil s roofing systems can help contribute to obtaining LEED points.
Creating Efficient HVAC Systems
Creating Efficient HVAC Systems Heating and Cooling Fundamentals for Commercial Buildings Heating, ventilating, and air conditioning (HVAC) systems account for nearly half of the energy used in a typical
Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
