1 MPROVED FURNACE COOLNG WATER PRESSURE LEAK DETECTON SYSTEM AT VALE 1 B. Bussell, 2 J. Janzen, 3 M. St.Amant, 4R. Miron, 5 M. Emond, 6w. Braun, 7 T. Gerritsen 1 Hatch Ltd, 40 Elm Street, Unit ND 255, Sudbury, Ontario, Canada, [email protected] 2 Hatch Ltd, 2800 Speakman Drive, Mississauga, Ontario, Canada, [email protected] 3 Vale Canada Ltd., 18 Rink Street, Copper Cliff Smelter, Ontario, Canada, [email protected] 4 Vale Canada Ltd., 18 Rink Street, Copper Cliff Smelter, Ontario, Canada, [email protected] 5 Hatch Ltd., 40 Elm Street, ND 255, Sudbury, Ontario, Canada, [email protected] 6 Hatch Ltd., 2800 Speakman Drive, Mississauga, Ontario, Canada, [email protected] 7 Hatch Ltd., 2800 Speakman Drive, Mississauga, Ontario, Canada, [email protected] ABSTRACT Vale have improved the safety, reliability and operability of the Flash Furnace No. 1 and Flash Furnace No. 2 with the installation of the Hatch Pressure Leak Detection System on each furnace and associated mechanical and controls improvements therein. The Pressure Leak Detection System monitors the integrity of the 99 tested water circuits per furnace with an accuracy in the order of drops of water per minute. Compared to other techniques, pressure leak detection is the best method known by Hatch to detect small leaks. The project incorporated novel design to allow installation and commissioning to take place without impact on production. The system was retro.fitted in a very tight timeframe. The systems have been accepted by Vale and are being fully used by operations. This paper further clarifies the design of the system and its associated benefits. KEYWORDS: Leak detection system, water pressure, copper coolers. 1. NTRODUCTON Vale have installed, in 2011, a Hatch Pressure Leak Detection System on two :furnaces in Copper Cliff and improved the safety, reliability and operability. This Pressure Leak Detection System compliments the existing course continuous flow leak detection system on both flash furnaces as it uses the detection principle of loss of static pressure. The design and installation were organized to minimize the impact on productio~ while still completing the full header replacement in a short time frame. The system incorporates mechanical and controls design improvements which improve the Vale operability of the furnaces. This paper elaborates the drivers for the installation of the system, compares different detection techniques, describes the system in technical details, including the mechanical details and discusses the performance of the system. 2. WHY LEAK DETECTON S MPORTANT The operating of a water cooled furnace involves the continuous maintenance of the required pipes in and around the walls of the furnace. A water pipe with even a small leak can cause permanent damage by hydrating the refractory brick in the wal~ as well as cause explosions if coming into contact with super heated matte. 377
2 Companies leading in the safe operation of their capital equipment understand that equipment damage significantly impacts their business. Ore smelting furnaces are core process equipment operating at high temperatures in a hazardous environment and are a priority area for companies to improve safety, operation and longevity. Governments are also promoting best practice in order to improve operator safety in hazardous environments. mprovements in Plant safety improves asset protection and lowers the operating cost of the facility. Furnace damage would result in loss of productio~ which overwhelms the safety system, installation and repair costs. Asset protection concepts include a properly designed, well built and a correctly operated furnace. With the operation portion of the work, including regular valid integrity checks (frequency dependent on data being measured), monitoring furnace integrity provides the information for maintenance to repair weak or worn components in a planned manner. Additionally, operators and maintenance personnel would receive warnings and integrity check feedback that can prevent major damage from occurring to a furnace when small problems start to develop. Taken together, this monitoring and operations philosophy increases the productivity of a furnace. 3. AVALABLE LEAK DETECTON TECHNOLOGES There are a number of methods that are adopted to detect leaks in furnace cooling systems. Leak Detection in its simplest form involves a regular visual inspection of the water pipes by the maintenance department. This method is limited in that leaks inside copper cooling blocks or in concealed piping are not visible. There is the added safety risk of persons spending more time within close proximity of the furnace. A continuous course leak detection system using flow rate comparison is a popular form of leak detection used on furnaces. By measuring the flow on the supply and return side of the furnace water cooling circuit, a greater reading on the supply side would represent a leak in the piping. The strength of this method being that this is a continuous form of leak detection which is quick to detect a hose from completely disconnecting. The weakness is that it is susceptible to measurement errors due to air in the water, flow meter installation and instrument inaccuracies. n some cases only leaks greater than 4 litres per minute can be detected. Leak detection based on the change of static pressure is the best method for detecting small leaks in a water circuit. The approach is to momentarily stop the flow in the water circuit and trap the pressurized water between the two newly installed entry and exit valves. The return valve is closed before the supply valve to make sure there is water in the coolers at all times and that the supply header water pressure is maintained in-between the valves. When the short test is complete, the valves are automatically opened and water flow is returned to that circuit. A pressure transmitter is used to accurately monitor a drop in pressure which can be equated to a leak. Leaks as small as a few drops per minute can be detected. This is not a continuous leak detection method, but it can be automatically run at regular intervals. 4. WHAT WAS NSTALLED AT VALE The Nickel Smelter at Vale already had, on some critical circuits, a flow leak detection system based on two flow meters. The pressure leak detection system was installed on the Vale furnaces to complement the existing flow leak detection system. The pressure leak detection system was installed on 99 circuits per furnace (198 total). The system not only detects a leak, but indicates on which circuit it is on. The water quality at Vale, because of the open sump pump feed system, was a concern for the implementation of the system This was evident with the build-up in the old headers replaced during 378
3 the shutdown and the effect on existing valves. Modifications were made to the seals of the valves installed for the leak detection to make them more resilient to build-up of debris. The pressure transmitters installed were less sensitive than the valves to dirt build-up. The air quality was also a concern due to the moisture content, as well as the variable pressure experienced in some areas the Plant. Specialized air filters and upsized valve diaphragms were installed to provide reliability for the system. The system was controlled independently to the furnace control to prevent any interference. The system was based on two Foxboro DCS (Distnbuted Control System) controllers per furnace installed in the field and developed on Foxboro's FCS (Foxboro Control Software), also known as EE (nfusion Engineering Environment). Below is a layout of the equipment that was used to perform the pressure leak detection. The flow transmitters and RTD existed prior to the installation. Supply Water Header Supply Valve ent FoxboroDCS Flow transmitter Pressure transmitter Return Valve RTD Return Water Header Figure 1: Pressure leak detection system equipment The valves used for the pressure leak detection are critical for safe repeatable operation and so the valve selection was subject to the following criteria: Valve able to release water pressure, in the closed pressure vessel created between the valves, when pre-determined levels are reached. Valve set to fail open - This is to ensure that the water cooling is not inhibited for long enough to cause damage to the equipment in the event ofa failed valve. Ability to seal closed against the system water pressure with the available instrument air pressure. Resilient to dirty water. Easy to service and replace. 379
4 5. PROJECT REALZATON 5.1. Mechanical design and installation The mechanical design and installation portion of the Project provided a number of challenges. The amount of equipment installed would have to increase, the schedule was predetermined and Vale wished for improved equipment access and ergonomics. To understand the magnitude of the changes, it is important to understand the existing piping situation before the start of the Project: Zero allocation for spares to the point that previous additional loops of pipe had to be installed in circuits to accommodate new instrwnents. Some instrwnents required a ladder for access. The water circuits were so close to each other that the instrumentation had to be staggered forward and back to allow it to fit. Sometimes the instrumentation from an adjacent circuit would have to be removed to allow the instruments of a circuit to be removed. A picture is provided in figure 2, for the reader to understand the congested nature of the cooling water headers. Figure 2: Original and new headers Due to the time constraints out the box thinlcing was used to make the minimal amount of changes possible, but still achieve the objectives. The following header improvements were made to achieve the objectives: Simplified Maintenance: Completely new supply and return headers were designed for offsite prefabrication as modules and then retrofitted to the existing piping tie in points. The new headers allowed instrumentation and mechanical equipment to be installed in a new location around the furnaces, improving ergonomics and simplifying maintenance. mproved ergonomics: The header layout was improved to provide front and back access to equipment and instrumentation. This design provided additional space for the new instruments and ensured that all instruments were within comfortable reach of maintenance or operational personnel. mproved Access: Headers were made accessible by relocating them to areas where they could be more easily maintained and accessed. mprove instrumentation data: The pressure transmitters installed were based on the Rosemount Foundation FieWbus {FF) network type. The FF transmitters have the advantage of 380
5 being able to self diagnose if their elements have build-up and signal that they require maintenance. Additionally, they were designed into the header in a protected location, to improve their longevity. Speed up installation: The pneumatic piping was based on a new heat resistant :flexible hose technology. This material reduced the installation time and the space required to run the hosing for the 396 valves installed. The engineering design, manufilcturing and installation processes were very compressed because of the schedule. To minimize total manufacturing and installation time, the headers were manufactured, assembled and tested off-site and installed as complete units at Vale. The controls and installation work was organized into work which would need to be performed during the furnace shutdown and work which could be completed while the furnaces were operating. The in-line piping equipment and instrumentation were installed during the shutdown, so as not to interfere with the production. As a result the work fitted within the Plant shutdown period, which resulted in less potential downtime for the Plant. The remainder of the installation was completed on the operating furnaces in 24 working days Controls commissioning With the shutdown window for the rebuild kept to a nummum, final installation and commissioning of the leak detection system could be performed after restart of furnace operation. With the Plant at full production, time could be taken to ensure that the installation of the system could be performed with the highest safety and quality standards and to the clients installation preferences. Upon completion of the installation work, an integrated team of Vale, Hatch and the installation Contractor was created to commission the system A total of99 circuits per furnace (198 total) had to be commissioned with the leak detection system. This was completed in 30 working days. The integrated team provided the controls, operations, construction and engineering capability to speed up commissioning while safely maintaining Plant operation. The integrated team eased the transfer of operational and maintenance information to the operating Plant SOFTWARE DEVELOPMENT AND CUSTOMZATON The Standard Hatch Pressure Leak Detection software is supported on the Allen-Bradley and Siemens platform although custom platforms are possible based on owners standards. Vale wished to standardize their controls on the new Foxboro DCS known as the Foxboro Control Software (FCS). This system represents the first ever implementation of FCS in Canada. Creative engineering was required by Hatch to implement the sequential state logic on the DCS using the new FCS development. Typically a DCS is not efficient with performing sequential logic which made a large proportion of this system. To execute this, task time slicing and task prioritization was used to reduce the loading on the processors. 6. SAMPLEDATA The leak detection system assumes that, when both valves are closed, there is a fixed volume of water in the pipe at a given pressure. Furnace equipment that are exposed to a lot of heat flux might show a slight increase in pressure during a test if there is no leak. n this case the length of the test is reduced if necessary to ensure that the equipment doesn't approach its maximum operating temperatures. A leak would cause a reduction in water quantity and a corresponding drop in water pressure, even if a heat flux is being applied. 381
6 The precision of the system is dependent on the length of piping and the supply header pressure. At Vale furnaces, a leak of a drop every few seconds was successfully detected on multiple circuits, verifying the expected accuracy of the system Below is a screenshot showing the pressure trend during a test that failed due to a 30 drop measured leak test. The water leak was simulated at the return end of the circuit, near the pressure transmitter and the return valve. The phases of the test can be seen in figure 3 and are detailed below: 1. The flat line section at 250 kpa is the return header water pressure with the water flowing before the test starts. 2. When the return valve is closed, the flow stops and the header pressure is transferred through the water piping up to the return valve with a static pressure of approximately 730 kpa (dependant on the header). 3. The supply valve is closed. There is no effect seen on the graph as the flow is already stopped and the pressure on either side of that valve is equal. 4. The negative slope on the graph shows the loss of pressure due to the measured 30 drops released from the water pipe over 10 seconds. The pressure reading dropped by 3 5 kpa. The pressure drop is related to the volume of water in the pipe. 5. Both valves are re-opened. 6. The return header pressure returns to normal as the flow through the circuit returns. 3_ 1\1 4,_ kpa 2 5 J \ f 1 \.{ Time Figure 3: Pressure transmitter trend with a 30 drop per 10 second leak A summary of various test results are shown in the figures 4 below: ~ ro o~ l" kpa 10 Drops J No Drops r ' ~ T me Figure 4: Pressure transmitter trends (from left to right) 20 drop leak, 10 drop leak and no leak 382
7 The table 1 below summarizes the data from the above trends and highlights the system's ability to accurately depict leaks in circuits. The Vale operations personnel physically confirmed the water dripping from a valve interface outside of the furnace. The system detected a leak of 1 drop in the water circuit every three seconds. This test result developed the operations confidence in the system. Table 1: Results from Simulated Water Leaks Chan2e in water pressure duridj! the simulated leak test 30 dron leak in 10 seconds -35 kpa 20 drop leak in 10 seconds -24 kpa 10 drop leak in 10 seconds -11 kpa No leak +l kpa n the first three months following the commissioning of the system, three water leaks around the furnace, two of which were concealed, have been detected by the system. Two additional leaking bypass valves were detected at the headers. With these results, the system has added its intended value to the Client. 7. EXPECTED SSUES GONG FORWARD The Hatch Pressure Leak Detection System has improved the safety of the Vale flash :furnaces. The system detects fine water leaks on furnace coolers and the associated water pipes, accurately, reliably and safely. Engineering challenges associated with system have been: Engineering configuration of pressure drop threshold, as well as an operating time, sufficient to detect any leaks that may occur in the circuit. The threshold is a dead band set before a circuit is marked as having a leak. The threshold needs to be fine tuned over time as the system is operated. A threshold too low will result in maintenance crews looking for leaks that don't exist or are too small to find. A threshold too high will limit the systems accuracy and early detection of small leaks. Development of an investigation procedure to identify the root cause of a pressure test failure and to ensure that the appropriate action is taken. A software manual with maintenance recommendations and guidelines was provided to Vale. Vale further incorporated this manual information into the Plant standard Operating Procedures. The success of the system going forward is dependent on the operating personnel taking ownership. Training of operators to :facilitate understanding and acceptance of the pressure testing system. This challenge was overcome by both Hatch and Vale effort by demonstrating the system and responding to any questions. The quality of the cooling water at the Vale furnace could create potential issues going forward for the valves, piping and headers. This is the first time that the leak detection system has been installed on a Plant with water quality concerns and the effectiveness in spite of these conditions is still to be proven. 8. CONCLUSONS The opportunity to improve the safety, ergonomics and equipment will improve the operation of flash furnaces. The Hatch Pressure Leak Detection System installation at Vale on flash furnace 383
8 No. and flash furnace No. 2 has improved the safety of the furnaces, by detecting :fine water leaks, a few drops a second detection range. This system has clearly shown that it can provide accurate information about failures of circuits around the furnace for both operations and maintenance personnel. The Project was a success because of the comprehensive team of project, controls, operations, installation contractor and engineering, who ensured the success of the project for all involved parties. 9. ACKNOWLEDGEMENTS The author is extremely grateful to Vale for permission to publish this paper. would like to thank K. Robinson, R. Miron, M. St. Amant, K. Cushnie, S. Joyce and D. Foy for the support in this paper. would also like to thank my colleagues; M. Emond, T. Gerritsen, W. Braun, W. Berends, R. Sullivan, M. Prpic, M. Holt, S. szkula, S. Moledina, R. Gauthier, D. Gauthier and others in their help on the Project and this paper. 10. REFERENCES [1] Macrosty R., Nitschke S., Gerritsen T., Crowe C., "Advances in furnace monitoring: nstrumentation", (2009). [2] Braun W, Janzen J, Bussell B.," Automatic Pressure Testing of Water Cooled Components in Furnaces", (2013). 384
World-Class Oil Sampling It is Possible
www.lubecontrol.com.au World-Class Oil Sampling It is Possible Lube Control Pty Ltd Providing lubrication solutions! Unit 5/53 Norfolk Rd, Marion, SA 5043 t: (08) 8298 5563 f: (08) 8298 6253 e: [email protected]
Safety Requirements Specification Guideline
Safety Requirements Specification Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] -1- Summary Safety Requirement
Hydrate Occurrence in Centrifugal Compressor Systems
Hydrate Occurrence in Centrifugal Compressor Systems Orlando Donda Filho, Senior Engineer, Petrobras Eder Ramalho, Fleet Manager, Caterpillar Solar Turbines, Macaé Pedro Antonio Lima Donda, Senior Maintenance
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Hydraulic Pipeline Application Modules PSI s Tools to Support Pipeline Operation
Hydraulic Pipeline Application Modules PSI s Tools to Support Pipeline Operation Inhalt 1 Leak Detection and Location Modules... 3 1.1 Dynamic Balance Leak Detection... 3 1.2 Transient Model Leak Detection...
CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS
Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting
Industrial Steam System Process Control Schemes
Industrial Steam System Process Control Schemes This paper was developed to provide a basic understanding of the different process control schemes used in a typical steam system. This is however a fundamental
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com
MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent
Statement of Work. 3.0 Details of Service Pre Start-up. - 1 - Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary
Installation Service Statement of Work - 1 - Cooling Start-up Service Cooling Start-up Service Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0 Details
Monitoring, repair, and safety practices for electric furnace matte tapping
The Southern African Institute of Mining and Metallurgy Furnace Tapping Conference 2014 L. Thomson Monitoring, repair, and safety practices for electric furnace matte tapping L. Thomson Sudbury Integrated
KODAK VERSAMARK, INC.
KODAK VERSAMARK, INC. PREPARED BY : Gary Rowland 6/6/06 Kodak Versamark, Inc. 3000 Research Blvd. Dayton, Ohio 45420 APPROVED BY : Fire Suppression System Inspection, Testing and Maintenance SHEET 1 OF
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes
Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes Vincent Pedalino FSL Home Improvements Phoenix, AZ 1 HVAC Basics Ways to improve the performance of existing air conditioning
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
Maintaining Fire Protection Systems
Maintaining Fire Protection Systems Fire continues to be a major threat to your business and your personal safety. Each year several thousand people are injured or killed by fires and billions of dollars
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
Standard terms and conditions
Standard terms and conditions INTRODUCTION For the provision of a water service (Water Supply, Wastewater and Drainage) Under Section 73(2)(a) of the Water Services Act 2012, landowners may be entitled
Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards
Prevention through Design: Eliminating Confined Spaces and Minimizing Hazards American Industrial Hygiene Association Developed by the AIHA Confined Spaces Committee Approved by the AIHA Board of Directors
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
DIABLO VALLEY COLLEGE CATALOG 2015-2016
HEATING, VENTILATION, AIR CONDITIONING, REFRIGERATION - HVACR Tish Young, Dean Physical Sciences and Engineering Division Physical Sciences Building, Room 263 Possible career opportunities Upon successful
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
Reliability Modeling Software Defined
Reliability Modeling Software Defined Using Titan Reliability Modeling Software May 30, 2014 Prepared by: The Fidelis Group 122 West Way, Suite 300 Lake Jackson, TX 77566 Fidelis Group, LLC All Rights
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Extract of the White paper Reduce energy costs in compressed air systems by up to 60%
Extract of the White paper Reduce energy costs in compressed air systems by up to 60% How can potential energy savings be identified? There are various measures for realising potential savings in compressed
A cure for water damage in real estate
A cure for water damage in real estate Presented for BC Non-Profit Housing Association by Jeff Shearman, Zurich Services Corporation 2010 Zurich Canada Focused on our customer Reduce overall risk by reducing:
Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants
Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants Published in the Official State Gazette (BOE) No 283 of November 24 th 2009 Nuclear Safety Council Instruction
DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION
May 2010 DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION GUIDELINES FOR PERMITS ASSOCIATED WITH THE REPAIR OF FLOOD DAMAGED HOMES AND BUILDINGS The Department of Codes and Building Safety
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
OHIO MEDICAL CORPORATION. Medical Gas Panel. Installation and Maintenance Manual
OHIO MEDICAL CORPORATION Medical Gas Panel Installation and Maintenance Manual P/N 255105 (Rev.5) 08/2005 P/N 255105 (Rev.5) 08/2005 PAGE 2 OHIO MEDICAL CORPORATION PAGE 3 1.0 User Responsibilities The
Printing and Publishing Energy Savings Guide
Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT
SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants
The Worcester Greenstar System Filter An innovative solution for reducing system contaminants Protect your customer s heating system with the Greenstar System Filter Modern condensing boilers are precision
INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas
5006 Cherry Ridge Road Richmond, Texas 77406 281-342-9944 [email protected] INSPECTION PROPERTY ADDRESS: INSPECTION PERFORMED FOR: XXXX Drive Fort Bend County, Texas Mr. and Mrs. New Construction
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning
C-Bus Application Messages & Behaviour Chapter 25 Air Conditioning Document Number: CBUS-APP/25 Comments on this document should be addressed to: Engineering Manager Clipsal Integrated Systems PO Box 103
C3306 LOCKOUT/TAGOUT FOR AUTHORIZED EMPLOYEES. Leader s Guide. 2005, CLMI Training
C3306 LOCKOUT/TAGOUT FOR AUTHORIZED EMPLOYEES Leader s Guide 2005, CLMI Training LOCKOUT/TAGOUT FOR AUTHORIZED EMPLOYEES This easy-to-use Leader s Guide is provided to assist in conducting a successful
COMPREHENSIVE PROPERTY INSPECTIONS
COMPREHENSIVE PROPERTY INSPECTIONS Thank you for selecting CPI for your Deficiency Observation. A full home inspection was not performed on this property at the buyers request. This inspection is a limited
SANITARY SEWER BACKUP. Causes & Prevention
SANITARY SEWER BACKUP Causes & Prevention A. PURPOSE The purpose of this publication is twofold: 1. It provides homeowners with basic information on the causes of sanitary sewer backups. 2. It provides
Turbocharger system components, servicing
21-1 Turbocharger system components, servicing Engine codes: AAZ, 1Z, AHU Observe rules of cleanliness Page 21-10 Turbocharger hoses and lines, connecting Page 21-11 WARNING! Do not re-use any fasteners
Preventing Overheated Boiler Incidents
Preventing Overheated Boiler Incidents PSE&G Appliance Service October 2012 Runaway Boiler Explosion Review Items Hazard Background Past Incidents PSE&G Emergency Response Future Process Improvements What
Dynamic Modeling Of An Ozone Disinfection Facility
Dynamic Modeling Of An Ozone Disinfection Facility Michael Etheridge Black & Veatch 8400 Ward Parkway Kansas City, MO 64114 Presented to the Fourteenth Ozone World Congress August 25 th, 1999 ABSTRACT
Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control
Boiler control Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control Boilers are often the principal steam or hot-water generators in industrial
Alfa Laval PureBallast 3.1
Alfa Laval PureBallast 3.1 Ballast water treatment system 1000 m 3 /h system Alfa Laval PureBallast 3.1 is an automated inline treatment system for the biological disinfection of ballast water. Operating
COMMERCIAL REPORT / STOCK CONDITION SURVEY. Sydenham Hill Estate Sydenham Hill London SE 23
COMMERCIAL REPORT / STOCK CONDITION SURVEY For Sydenham Hill Estate Sydenham Hill London SE 23 Submission Prepared by Gas Advisory Services Limited Date: 4 th June 2013 Gas Advisory Services Limited Phoenix
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
THREE. Heating and Cooling
THREE Heating and Cooling 17 Condensation Drain Line The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. If your unit is located in the attic,
Tap-hole monitoring technologies
The Southern African Institute of Mining and Metallurgy Furnace Tapping Conference 2014 W. Braun, P. Gebski, R. MacRosty, R. Pula, A. Sadri, and W. Ying Tap-hole monitoring technologies W. Braun, P. Gebski,
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -
Doc. : 08C00031_e Date : 10.02.2009 Page : 1 / 9 ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric - (Preliminary) Doc. : 08C00031_e
PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY
PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY Scope These program criteria apply to programs having titles involving Electrical Engineering Technology including: electrical engineering, electrical
Essential NCPI Management Requirements for Next Generation Data Centers
Essential NCPI Requirements for Next Generation Data Centers By Ted Ives White Paper #14 1 Executive Summary The management of physical infrastructure in data centers can no longer be considered independently
HAZELBAKER CONSTRUCTION SERVICES 8965 QUARRY DRIVE NAPLES, FLORIDA (239)213-8046
8965 QUARRY DRIVE NAPLES, FLORIDA (239)213-8046 Page 1 of 9 Doc #: 1411-000 Date: 11/07/2014 Dwelling Address: 1234 Sample Road, Naples, FL 34120 Client Name: John and Jane Doe This four point inspection
WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES
WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES The following are suggestions to help you winterize your home plumbing. They are for homes where the heat is not left on during the winter months. There
IPB-IB ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS. BECK VIDEO Scan w/ Smartphone
IPB-IB R ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS BECK VIDEO Scan w/ Smartphone 1 Increasing Business Pressures Necessitate Boiler Control Improvements Today s industrial
Powers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
Link-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk
Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store
JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES
JUBILEE TECHNICAL TRAINING CENTRE TAKORADI POLYTECHNIC 2015 TRAINING PROGRAMMES Main Courses Duration: 26 weeks 1. NVQ Level 2 Performing Process Operation in Replicating Environment 2. NVQ Level 2 Performing
BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS
BUILDING OWNERS - SERVICE RELATED ISSUES FOR FIRE ALARM SYSTEMS Owners have numerous responsibilities as it pertains to the maintenance and operation of a building s fire safety equipment. The liabilities
COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A
COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A (All unshaded skill sets must be demonstrated/completed) PROTECT SELF AND OTHERS Identify, interpret, and
Section: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System
Section: R100 Bulletin: R100.51 Date: 07/13 Supersedes: New TRUST Your Water Level Steam you can depend on, 24/7 Boiler Level Indication System Boiler Level Indication System Where s your water? For over
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE
ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE Protected by one or more of the following U.S. Patents (3,507,354; 3,575,234; 3,596,936; 3,605,797; 3,685,329; 4,045,977; 4,698,982; 926,673 and
Noise associated with the ground water systems serving residential geothermal heat pumps
Noise associated with the ground water systems serving residential geothermal heat pumps Jeffrey L. FULLERTON 1 Acentech Incorporated, United States ABSTRACT Geothermal heat pumps are an energy efficient
Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5
PROTECTIVE PLUMBING - WHAT IS IT? TABLE OF CONTENTS Protective Plumbing What is it?...page 1 What is Foundation Drainage?...Page 2 What is a Sump Pumping System?...Page 4 Does Part of My Basement Floor
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute
CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute Cable Tray Wiring Systems Have Many Cost Advantages Cost is usually a major consideration in the selection of a wiring system.
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
Version: 1.0 Last Edited: 2005-10-27. Guideline
Process hazard and risk Comments on this report are gratefully received by Johan Hedberg at SP Swedish National Testing and Research Institute mailto:[email protected] -1- Summary This report will try
Realizing the Benefits of Finite Capacity Scheduling to Manage Batch Production Systems
Presented at the WBF North American Conference Baltimore, MD, USA 30 April - 4 May 2007 67 Alexander Drive PO Box 12277 Research Triangle Park, NC 27709 +1.919.314.3970 Fax: +1.919.314.3971 E-mail: [email protected]
Quality Assurance Program Quality Assurance Plan Periodic Audits Standard Operating Procedures Preventive Maintenance Outline Quality Assurance Plan (QAP) What is a QAP Why is a QAP required? What does
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Technician High Pressure Pump Guide for the 7.3 Power Stroke Engine
Technician High Pressure Pump Guide for the 7.3 Power Stroke Engine HIGH PRESSURE PUMP. PUMP LEAKS. ICP SYSTEM DIAGNOSTICS. REPAIR PARTS. TOOLS IPR TEST TOOLS AND ICP PUMP LEAK REPAIR High pressure pumps
Lessons Learned, Best Practices and Observations. 2014 2016 Plant Winterization Visits
Lessons Learned, Best Practices and Observations 2014 2016 Plant Winterization Visits EQUIPMENT PROTECTION: Although some of the observations and practices were unique to an entity, the following can be
Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
SEWER CLEANING, INSPECTION AND ASSESSMENT
3.1 OVERVIEW Chapter 3 SEWER CLEANING, INSPECTION AND ASSESSMENT Preventive maintenance protects the investment of the sanitary sewer collection system infrastructure. Higher frequency cleaning of gravity
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT
CITY OF SPRING LAKE PARK Code Enforcement Department 1301 81 st Avenue NE Spring Lake Park MN 55432 Business Phone 763-784-6491 Fax 763-792-7257 INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS
POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)
IM213P-MC 0312 0003 POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE) INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE
1 Which tool is used to correct internal hi-low when preparing a 4-in. steel pipe for welding? A. 4-in. grinder with cutting disc. B. Mini-grinder with flapper disc. C. Pencil grinder with cone stone.
Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems
Vehicle Fire Protection An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems 002792 Off-road vehicles do have fires Statistics show that off-road vehicles burn with alarming frequency. These
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
The troubleshooting guide is designed to provide a logical starting point to locate general problems that could
V. TROUBLESHOOTING The troubleshooting guide is designed to provide a logical starting point to locate general problems that could occur with the Ricon S2000/5000 Series Wheelchair Lift. However, not all
EXHIBIT A SCOPE OF WORK
EXHIBIT A SCOPE OF WORK 1. (Contractor) shall provide fire alarm system maintenance/repair/testing services as described herein to the California Department of Veterans Affairs (hereinafter CDVA, CalVet,
Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations
Stephen Lowe ASHRAE Hampton Roads Chapter Past President AECOM Design Mechanical Engineering Discipline Manager, Virginia Beach Division Professional Engineer Commonwealth of Virginia, NCEES BSME University
A Cover HVAC ENERGY EFFICIENT
A Cover HVAC ENERGY EFFICIENT EQUIPMENT toolkit 1 CONTENTS AND PARTNERS 2 Introduction 3 equipment & processes 3 Optimise operating settings 2 upgrade equipment 4 Seal the building 5 Rearrange air conditioning
Fundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
May 5, 2010. Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,
PROPERTY INSPECTION PROFESSIONALS May 5, 2010 Client Client Address Re: Inspection Address, Chicago, Illinois Dear Mr. Client, On May 4, 2010, Tomacor completed a property inspection of the above referenced
heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.
3 & cooling 17 heating 2010 PulteGroup, Inc. All Rights Reserved. condensation The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. Air conditioning
International Training Institute for the Sheet Metal and Air Conditioning Industry
American Council on Education - National Guide to College Credit for Workforce Training Page 1 of 13 International Training Institute for the Sheet Metal and Air Conditioning Industry The (ITI), formerly
1 ELGOTEAM ADVANCED SECURITY SYSTEMS Bi-directional spike barrier. Bi-directional spike barrier Customer Information packet
1 Customer Information packet For more information: [email protected] www.elgoteam.com 2 Chapter contents Subject Page number The company 3 Background 4 Applications 5 Advantages 6 Operating positions
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
Paralleling Switchgear
Paralleling Switchgear By Maurice D Mello, P.Eng. Systems Engineer, GE Consumer & Industrial, Canada What is Paralleling? Paralleling is the operation in which multiple power sources, usually two or more
Hydraulic Control Technology for Wind Turbine Generators
Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Hydraulic Control Technology for Wind Turbine Generators Extra
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause