Tips from the Help Desk
|
|
|
- Iris Adams
- 10 years ago
- Views:
Transcription
1 Tips from the Help Desk Questions & Answers from the Source Registration (SR) Help Desk for some common problems and unusual situations Contents CTRL+Click the questions below to go to the answers. Tips on Avoiding Common Errors Facility Name Change Facility Closure or Fee Review Requests Fuel Usage Lead emissions Emergency Generators Stack height Report on All Units Call the SR Help Desk before you submit a 2nd package... why? Remember to SUBMIT! What Units Must Be Reported (or not) Reminder: Complete SR = report on all units, including idle units NEW How do you enter data for Combined Units? How do you enter in the forms unusual exhausts, such as short vertical vents? Low NOx burners are they control devices? How should Ovens be reported? How should Dryers be reported? How should Flares be reported? How do I report emissions from the fuel use of a thermal oxidizer? What do you enter into the basis fields for restrictions if you don t have a permit? Is a Fireye flame monitor a monitor that must be recorded on the forms? Which SCC s should be used for residential boilers/water heaters at commercial/institutional facilities? Which SCC s should not be used on an AP1? Do you need to report small portable heating units in Source Registration? Do you report temporary emission units? Are there any emissions units you don t need to report in your Source Registration? What units fall under the insignificant activity class at 310 CMR 7 Appendix C(5)(i)17 for HVAC? How To Report on Special Cases Reporting on Tanks When does a tank need to be reported? What do you enter for Q7.d Temperature on the AP4 tank form? Is there a de minimis concentration of organic matter below which an AP4 is not required for a tank? When must you calculate emissions from tanks? NEW What are combined units and when can fuel burning equipment be combined as one emission unit? Page 1
2 Tips on Avoiding Common Errors Facility Name Change If your facility s name or address has changed, you should contact the data manager in your MassDEP Regional Office before you start work on your forms (or you will have to start the forms over again to include the name change). Find out which data manager to contact on the Source Registration Web Page. Facility Closure or Fee Review Requests If a facility has closed, changed status relative to a permit, or wishes to request a review of its compliance fee, you must contact your MassDEP Regional Office Data Manager. You may note these facts in your Source Registration, but you must also contact the Data Manager for your request to be processed. See Contacts at the Source Registration web page. Fuel Usage When entering the amount of fuel burned (or other throughput) be sure to check the units of measure displayed in the units field to avoid time-consuming errors. NOTE that sometimes throughput must be reported in units of 1000 gallons rather than gallons, or million cubic feet rather than cubic feet. on the AP1 form in field B.1.h for each generator (or any other restriction under a permit). The 300-hour restriction is found in 310 CMR 7.02(8)i.2, or 7.03 (10)(a) or 7.26(42)d.1 (see Stack height On the Stack form, please note that the height of a stack should be given from the ground. Report on All Units You must report on all emission units at the facility, including those that are idle. Call the SR Help Desk before you submit a 2nd package... why? If you need to submit a 2 nd package this year for any reason (e.g., to add something or correct an error), consult with us first by ing [email protected] or calling the SR Help Desk. The reason is that we want to make sure your first submittal wrote correctly to the database before you try to open a new package. This ensures your data prefills correctly and that the total emissions are calculated correctly. This is important because we did have some problems with packages failing to write to the database last year. This year we want to be sure any problems are fixed before you submit a second time. Lead emissions If your facility emits lead to the air, you need to report this using the Other pollutant column on the form for the unit that emits the lead. Emergency Generators Owners/operators of a facility with emergency generators must report their 300-hour use restriction Remember to SUBMIT! Some filers do not realize there is a separate Submit step that follows the signature. They fail to take that last step and are late. Please remember to continue until you have a receipt for your submittal to ensure you have filed. Page 2
3 What Units Must Be Reported (or not) Reminder: Complete SR = report on all units, including idle units Please remember that a complete SR submittal includes a report on ALL emission units at a facility, including those that are idle. Note that if you fail to report on an idle unit for 2 years, you could also trigger requirements for a new plan approval (see 310 CMR 7.02 (3)(m)). If a unit has been permanently removed but it is still listed on the Overview form as part of your facility, then you must complete the form for that unit one last time, entering a decommission date. That tells MassDEP that the unit is permanently removed/disabled and will keep it from appearing on the list of equipment at your facility in future Source Registrations. Similarly, if your entire facility is idle, you still must file a Source Registration when it is due. consider reporting it with one of the existing units on that unit s form (they would become a combined unit). The only exception is a unit used for construction equipment that is, a generator used only to power construction equipment does not need to be reported in Source Registration. Note, however, that a temporary generator used to replace or augment an existing unit at the facility (that is, it is used to power the facility's equipment) during construction would need to be reported. Are there any emissions units you don t need to report in your Source Registration? No, with a very few exceptions. In general all emissions units must be reported on in each Source Registration. As stated in 310 CMR 7.12 (3)(a)(1), the only emissions units that you do not need to report are those listed as Insignificant Activities under 310 CMR 7 Appendix C(5)(i), excerpted on the next page. Do you need to report small portable heating units in Source Registration? No small portable heating units, defined as those which have fuel tanks with less than 10 gallons capacity, need not be reported on Source Registrations. Do you report temporary emission units? Yes, in some cases. If an emission unit is a temporary or mobile unit (such as a temporary emergency generator or a temporary boiler mounted on a trailer) but is of a type that would be reported on if it were fixed and permanent, then it must be included in your Source Registration IF it operated for 120 days or more during the Year of Record. Note that if the temporary unit is very similar to other units at the facility, you should What units fall under the insignificant activity class at 310 CMR 7 Appendix C(5)(i)17 for HVAC? Insignificant activities not required to be reported in Source Registration include: ventilating systems used exclusively for heating and cooling buildings, for the comfort of people living or working within the building serviced by said system, which EPA has determined need not be contained in an operating permit. This exclusion from Source Registration applies only to those heating/cooling units on which EPA has made a determination in an operating permit that is, the only units excluded under this provision are those at facilities subject to the operating permit program. Page 3
4 310 CMR 7 Appendix C(5)(i) (i) Insignificant Activities. Notwithstanding 310 CMR 7.00: Appendix C(5)(h) any emission unit(s) that is part of the following activities is exempt from the requirements of 310 CMR 7.00: Appendix C: 1. Open burning conducted in accordance with the requirements of 310 CMR 7.07(2), 7.07(3)(a) and 7.07(3)(e); 2. Office activities and the equipment and implements used therein, such as typewriters, printers, and pens; 3. Interior maintenance activities and the equipment and supplies used therein, such as janitorial cleaning products and air fresheners; this does not include any cleaning of production equipment or activities regulated by 310 CMR 7.18; 4. Bathroom and locker room ventilation and maintenance; 5. Copying and duplication activities for internal use and for support of office activities at the facility; 6. The activities not regulated by 310 CMR 7.18 in maintenance shops, such as welding, gluing, soldering; 7. First aid or emergency medical care provided at the facility, including related activities such as sterilization and medicine preparation; 8. Laundry operations that service uniforms or other clothing used at the facility that are not regulated by 310 CMR 7.18; 9. Architectural maintenance activities conducted to take care of the buildings and structures at the facility, including repainting, reroofing, and sandblasting; 10. Exterior maintenance activities conducted to take care of the grounds of the facility, including parking lots and lawn maintenance; 12. The use of portable space heaters which reasonably can be carried and relocated by an employee; 13. Liquid petroleum gas (LPG) or petroleum fuels used to power the facility's mobile equipment and not otherwise regulated by the Department; 14. Emergency vents not subject to the accidental release regulations. 15. surface coating and painting processes which exclusively use non-refillable aerosol cans; 16. vacuum cleaning systems used exclusively for commercial or residential housekeeping; 17. ventilating systems used exclusively for heating and cooling buildings, for the comfort of people living or working within the building serviced by said system, which EPA has determined need not be contained in an operating permit; 18. ventilating and exhaust systems for laboratory hoods used: a. by academic institutions for academic purposes. b. by hospitals and medical care facilities used for medical care purposes and medical research only. c. by laboratories which perform laboratory scale activities as defined by OSHA. d. by facilities for quality assurance and quality control testing and sampling activities. 19. surface coating and printing processes used exclusively for educational purposes in educational institution excluding those emission units regulated by 310 CMR 7.18; and 20. kilns or ventilating hoods for art or ceramic curricula at colleges, primary or secondary schools. 11. Food preparation to service facility cafeterias and dining rooms; Page 4
5 How To Report on Special Cases What are combined units and when can fuel burning equipment be combined as one emission unit? Fuel burning units can be combined as one emission unit and reported on one AP1 or AP2 form. This is to make it easier to report large numbers of small units. The number of units in a combined unit must be entered in the combined units field on the AP1/2. Combustion units may be combined subject to certain restrictions below. Restrictions on Combined Units Each individual unit within a combined unit must: 1. be of the same general type (not necessarily identical) 2. use the same fuel(s) Make/Model No use the most common make/model or enter combined. Installation Date enter the install date for the oldest of the individual units. Permit Date enter the most recent permit number and date for the units. Max capacity / potential enter the sum of the maximum capacities of all of the individual units as the maximum capacity for the combined unit. Decommission date do not decommission until the last individual unit is gone; if you need to add or subtract units from the combined unit, then increase or decrease the value in the Combined Units field to reflect the change and explain in the Notes field. Explain in the Notes field which units have been combined (list them) and any issues or oddities about the combined unit. Make a note in the Notes field with the locations of the combined units if they are not in the same building at the facility. 3. be subject to the same regulatory restrictions 4. be below the following maximum input thresholds: Distillate oil MMBtu / hour or 72 gal / hour; Residual oil 10 MMBtu / hour or 64 gal / hour; Natural gas 10 MMBtu / hour or 100 Therms / hour; Solid fuel 3 MMBtu / hour; Used oil fuel 3 MMBtu / hour or 19 gal / hour; Landfill gas 3 MMBtu / hour or 6,000 cf / hour 5. AND the total heat input of all units in the combined unit does not exceed 50 mmbtu/hour. How do you enter in the forms unusual exhausts, such as short vertical vents? Some units exhaust vertically, but have housings shorter than 10 ft above the roof of the building (e.g., ventilation exhausts that may be 3-5 ft tall. This type of release point does not require a Stack form it is considered to be a Non-Stack release point. The forms do not (yet) have a specific code for this type of exhaust. You should select fugitive for such a vertical vent (< 10 feet tall). Then describe the release point briefly in the Notes field. How do you enter data for Combined Units? When entering data for combined units use these guidelines: Low NOx burners are they control devices? No they are part of your equipment and should not be logged as separate control devices. If you have low NOx burners you should use emission factors that take into Page 5
6 account their lower emissions. You should also mention in the notes that the unit incorporates low NOx burners. You can find such emission factors in EPA s emission factor database at: How should Ovens be reported? An oven should be reported on 1 form only. Use an AP1 for an oven that has no emissions other than those from fuel combustion (such as an oven used for driving off water). Use an AP2 where there are emissions from the material being baked (such as where solvents are being baked off). On an AP2, the combustion emissions will be reported as one material throughput (segment) and emissions from the material being baked as another segment. Remember to use an SCC for combustion for the fuel segment. If you need to have ovens that are currently AP1 s recoded to AP2 s, please contact the SR Help Desk before you begin entering data we can change the forms for you. If you have already reported an oven on an AP1, you do NOT need to make any changes it will be accepted this year. How should Dryers be reported? A dryer should be reported on 1 form only. Use an AP1 for a dryer that has no emissions other than those from the fuel combustion (such as for a dryer that produces only water vapor). However, if the dryer is combined in a unit with a spray or print operation, use an AP2 to ensure that the %VOC is reported (this field is only on an AP2). As with an oven, the combustion emissions will be reported as one material throughput (segment) and emissions from the material being dried as another segment. Remember to use an SCC for combustion for the fuel segment. If there is a spray or print process, but is reported as a separate emissions unit (a separate AP2) then you can used an AP1 because you will be reporting only the fuel combustion (again, be sure to use a combustion SCC on the AP1). If you need to have dryers that are currently AP1 s recoded to AP2 s, please contact the SR Help Desk before you begin entering data we can change the forms for you. If you have already reported a dryer on an AP1, you do NOT need to make any changes it will be accepted this year. How should Flares be reported? Where a flare is a control device on a process emission unit it should be reported in the control device portion of the AP2 for the unit whose emissions it is controlling. In the past, many flares were reported as incinerators (AP3s) we are trying to ensure that all control flares are now reported on AP2 forms. If you have a control flare that is an AP3, please do the following: (1) report the flare on the AP2 that it controls, (2) note in the Notes field on the AP2 that you are reporting the flare on the AP2 rather than the AP3, and (3) enter a decommission date in the AP3 (this will cause it to be removed from future SR packages) and enter 0 for all throughputs and emissions on the AP3. Alternatively, you can [email protected] requesting that the AP3 be decommissioned by the SR Help Desk, in which case you will not need to include the form in your package. EXCEPTION: Flares on landfills should be reported on an AP1. Again, if you need a unit recoded, contact the SR Help Desk before you start entering data. Page 6
7 How do I report emissions from the fuel use of a thermal oxidizer? If you have a thermal oxidizer on an emission unit that emits VOCs, you also need to report the emissions from the combustion of natural gas. To do this, add another segment or raw material to the AP-2 form for the unit in order to report emissions from natural gas combustion. After you check Add Raw Material and validate, another Section B will be generated on which you can enter the natural gas combustion emissions. You will need to enter a natural gas combustion SCC and look up the emission factors for natural gas combustion and calculate the emissions yourself. What do you enter into the basis fields for restrictions if you don t have a permit? If a unit has a restriction that is based on a regulatory limit rather than a permit condition, then enter the regulatory citation (e.g., 310 CMR. 7.X(XX)). All emissions or throughput restrictions will have a basis. Which SCC s should not be used on an AP1? The AP1 form is for combustion, and the auto calculation feature relies on the use of combustion SCC s as the basis for selecting emission factors. SCC s that are not for combustion should not be used on an AP1 with auto calculation. A new validation feature of the forms will prevent a user from trying to auto calculate emissions using a non-combustion SCC (i.e., one that does not have EPA emissions factors associated with it). If you use a non-combustion SCC on an AP1, you must do your own emissions calculations. You can identify combustion SCC from the Category field in the list of valid SCC s posted on the SR Web Page. Is a Fireye flame monitor a monitor that must be recorded on the forms? No a Fireye is a r brand of flame monitor. Flame monitors in general do not need to be reported on an AP1. Which SCC s should be used for residential boilers/water heaters at commercial/institutional facilities? Use SCC for distillate oil and for Natural Gas. Page 7
8 Reporting on Tanks When does a tank need to be reported? You must file an AP-4 form for each below- or aboveground storage container that is 500 gallons or larger and stores liquid organic material. Tanks can be combined if the combined capacity does not exceed 50,000 gallons, they are the same construction, and store the same material(s). Do not combine above ground with below ground tanks use separate AP4 forms for each type. Note that if a single tank is 40,000 gallons or larger, you may need to report emissions for the tank see question below. Tanks containing wastewater with organic material and waste organic material that will be disposed of off-site need not be reported in Source Registration. What do you enter for Q7.d Temperature on the AP4 tank form? This field is intended to capture the temperature at which the material is stored. If underground, a default value of 55 F may be used if the tank is not heated or cooled. If above ground, a default of 48 F may be used if the tank is not heated or cooled. If the tank is inside a building, then the temperature at which the building is kept should be given. If the tank is heated or cooled, the temperature of the contents should be given. Is there a de minimis concentration of organic matter below which an AP4 is not required for a tank? No however the objective of the AP4 is to gather data on tanks storing fuel or materials or products. It is not intended to capture wastewater that may contain some organic material. So a waste oil tank must be reported where that oil will be a feed stock or fuel, but a waste oil or waste water tank which contains some oil that will be disposed of off-site need not be reported. When must you calculate emissions from tanks? Emissions need to be calculated for above ground storage tanks with a capacity equal to or greater than 40,000 gallons containing liquid organic material having a vapor pressure of 1.5 pounds per square inch absolute or greater under actual storage conditions, and for any storage tank with a capacity equal to or greater than 1 million gallons. Emissions calculations are not required for any other type/size of tank. Emissions for such tanks must be reported on an AP2 form. They may be added as additional materials/throughputs (segments) to an existing AP2 that reports emissions for the tank loading equipment, or they may be reported on a separate AP2. All tanks may be reported on one AP2 separate segments/forms for each tank are not required (although you may separate them if you wish for clarity). Report emissions for standing/breathing loss separate from drawdown (that is, make them 2 separate segments). Actual working loss emissions for such tanks are calculated based on the actual loading/unloading of the tanks (not apportioned rack throughput). The potential emissions are calculated by assuming the total unloading rack potential throughput through each tank, and then summing these. The potential emissions from drawdown should be reported as equal to actual drawdown emissions. Be sure to provide the Tanks model parameters used in the Notes or as an attachment. sranswers 29 mar 2011.doc Page 8
INDEX 9-7-100 GENERAL
REGULATION 9 INORGANIC GASEOUS POLLUTANTS RULE 7 NITROGEN OXIDES AND CARBON MONOXIDE FROM INDUSTRIAL, INSTITUTIONAL AND COMMERCIAL BOILERS, STEAM GENERATORS AND PROCESS HEATERS INDEX 9-7-100 GENERAL 9-7-101
Notes. Material 1. Appropriate Flammable Liquids
29 CFR 1910.106 Flammable Materials Flammable Liquids Preparation 1. Read Applicable Background information and related Company Policy Chapter. 2. Make Copies of this Lesson Plan for Personnel 3. Make
State of New Jersey. General Permit. For. Boilers and Heaters [Individually Less Than 10 MMBTU/HR]
State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit For This General Permit allows for the construction, installation, reconstruction and operation of single
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS
Rule 1146.2 - EMISSIONS OF OXIDES OF NITROGEN FROM LARGE WATER HEATERS AND SMALL BOILERS (a) Purpose and Applicability The purpose of this rule is to reduce NOx emissions from natural gas-fired large (commercial)
Potential to Emit A Guide for Small Businesses
1EPA United States Office of Air Quality EPA-456/B-98-003 Environmental Protection Planning and Standards October 1998 Agency Research Triangle Park, NC Potential to Emit A Guide for Small Businesses EPA-456/B-98-003
A Guide to Hazardous Substance Storage Capacity
New Jersey Department of Environmental Protection Bureau of Release Prevention A Guide to Hazardous Substance Storage Capacity August 7, 2014 Introduction The Spill Compensation and Control Act (the Spill
RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE
(Adopted January 6, 1978)(Amended August 3, 1979)(Amended July 11, 1980) (Amended August 3, 1990)(Amended December 7, 1990) (Amended November 17, 2000) RULE 1102. DRY CLEANERS USING SOLVENT OTHER THAN
Propane Gas Underground Systems: Residential Infrastructure Requirements and Energy Benefits
Propane Gas Underground Systems: Residential Infrastructure Requirements and Energy Benefits AIA Best Practices The Propane Education & Research Council and HanleyWood are registered providers with the
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
PART 70 PERMIT TO OPERATE
G Missouri Department of Natural Resources ~ ~ ~ Air Pollution Control Program PART 70 PERMIT TO OPERATE Under the authority of RSMo 643 and the Federal Clean Air Act the applicant is authorized to operate
NSPS Subpart OOOO: Applicability and Compliance Basics
NSPS Subpart OOOO: Applicability and Compliance Basics Kentucky Oil & Gas Association 2013 Western Kentucky Meeting September 12, 2013 Roy Rakiewicz All4 Inc. Rob Flynn Environmental Standards, Inc. www.all4inc.com
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
A Guide to Calculating Your Boiler Emissions. A step-by-step manual for your convenience
A Guide to Calculating Your Boiler Emissions A step-by-step manual for your convenience Contents The Importance of Emissions Calculations... 3 Why You Need to Calculate Your Boiler Emissions... 4 The Newest
Section III Hazardous Materials Management
Section III Hazardous Materials Management This section of the Everyday Hazmat User s Training Guide covers various types of hazardous materials commonly found in the USDA Forest Service. Federal regulations
2. Do I have to certify? 1. What is the ERP Installation Compliance Certification? 3. How do I submit a Compliance Certification?
Compliance Certification Instructions Emergency Engines and Emergency Turbines 1. What is the ERP Installation Compliance Certification? Operators of new emergency engines with a rated power output equal
Fuel and Energy Conversion and Equivalence Chart
Fuel and Energy Conversion and Equivalence Chart Please note, the fuel economy estimates within this document are examples only. Maine Public Service does not consult with customers regarding fuel source
WHEN IS A PERMIT REQUIRED?
WHEN IS A PERMIT REQUIRED? Any owner, builder, contractor, or other authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure,
A. Fire Protection Plan. B. Access and Parking
Standards for Construction Site Fire Safety For Use by Unidocs Member Agencies or where approved by your Local Jurisdiction Authority Cited: California Fire Code (CFC) These standards are intended to prescribe
Propane and Natural Gas Safety
Rialto Fire Department Fire and Life Safety Tips August 2010 Propane and Natural Gas Safety If you smell Propane or Natural Gas leave area immediately and call 911 U.S. fire departments responded to an
1.3 Properties of Coal
1.3 Properties of Classification is classified into three major types namely anthracite, bituminous, and lignite. However there is no clear demarcation between them and coal is also further classified
GENERAL AIR QUALITY OPERATING PERMIT FOR PERCHLOROETHYLENE DRY CLEANERS APPLICATION PACKAGE
PIMA COUNTY DEPARTMENT OF ENVIRONMENTAL QUALITY Air Program 33 N. Stone Avenue, Suite 700, Tucson, Arizona 85701 Phone: (520) 243-7400 GENERAL AIR QUALITY OPERATING PERMIT FOR PERCHLOROETHYLENE DRY CLEANERS
NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM. Dry Cleaner Compliance Calendar 2012
NEW JERSEY SMALL BUSINESS ENVIRONMENTAL ASSISTANCE PROGRAM Dry Cleaner Compliance Calendar 2012 Welcome The New Jersey Small Business Environmental Assistance Program developed this guidance document to
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.
Carbon Monoxide Detection in Commercial Buildings (
1 Technical Guideline for School Districts and BOCES to comply with regulations for Carbon Monoxide Detection in Commercial Buildings (Section 1228.4 of Part 1228 of Title 19 NYCRR). General: This document
Improper storage of potential pollutants will increase the risk of water pollution that may occur because of spills.
WQ-3 Best Management Practice (BMP) Water Quality Protection Guideline Secondary Containment Design and Operation Standards Section 1. Introduction According to the EPA, the majority of water pollution
The California GHG Emissions Reporting Tool
12/01/2010 11:48:54 Facility Information: Chevron Products Company - Richmond Refinery, 94802 Facility Name Chevron Products Company - Richmond Refinery, 94802 ARB ID 101384 Primary Sector Secondary Sectors
Sample Written Program. For. Flammable Liquids
Sample Written Program For Flammable Liquids 1 Flammable Liquids. (YOUR COMPANY NAME) Purpose Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and
Walkthrough Inspection Checklist
Walkthrough Inspection Checklist This checklist is to aid during an IAQ Walkthrough of the school. The checklist includes considerations both inside and outside the school building: Instructions: 1. Read
FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes
FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,
Plain English Guide for the Dry Cleaners Step By Step Approach to Understanding Federal Environmental Regulations
LOCAL DRY CLEANING SHOP Plain English Guide for the Dry Cleaners Step By Step Approach to Understanding Federal Environmental Regulations LOCAL DRY CLEANING SHOP Table of Contents I. Part I: Summary of
Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan
Extraction Oil and Gas, LLC. Diamond Valley Central Oil Terminal Waste Management Plan Scope: This Extraction Oil and Gas Waste Management Plan has been prepared to provide operations personnel at the
Subpart XX Standards of Performance. Terminals. Environmental Protection Agency 60.501
lpowell on DSK54DXVN1OFR with $$_JOB Environmental Protection Agency 60.501 a State under section 111(c) of the Act, approves reporting requirements or an alternative means of compliance surveillance adopted
Waste Oil Collection / Storage
ENVIRONMENTAL & REGULATORY SERVICES Storage Tank Regulation Section P. O. Box 7837 Madison, Wisconsin 53707-7837 TDD #: (608) 264-8777 http://www.commerce.state.wi.us http://www.wisconsin.gov Jim Doyle,
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
Control Device Requirements Charts For Oil and Gas Handling and Production Facilities
Device Charts For Oil and Gas Handling and Production Facilities Purpose/Scope: The purpose of this document is to provide standardized guidance for use by the regulated community and air permit reviewers,
Michigan Dry Cleaning Environmental Compliance Workbook
Michigan Dry Cleaning Environmental Compliance Workbook Michigan Department of Environmental Quality Environmental Science and Services Division Clean Air Assistance Program Jennifer M. Granholm, Governor
DRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
RTO UPGRADE PROVIDES COST SAVINGS AND PERFORMANCE IMPROVEMENTS
RTO UPGRADE PROVIDES COST SAVINGS AND PERFORMANCE IMPROVEMENTS Abstract Pollution abatement systems are a standard requirement for the solvent based coating processes, with planning these do not need to
Guidelines for Calculating and Reporting Emissions from Bulk Loading Operations December 2013
Guidelines for Calculating and Reporting Emissions from Bulk Loading Operations December 2013 The purpose of this document is to provide operators with guidelines in estimating emissions from loading of
FLORIDA HAZARDOUS WASTE MANAGEMENT REGULATIONS THAT DIFFER FROM FEDERAL REQUIREMENTS
FLORIDA HAZARDOUS WASTE MANAGEMENT REGULATIONS THAT DIFFER FROM FEDERAL REQUIREMENTS Chapter 1: Introduction General Notes Lead Agency: Florida Department of Environmental Protection (DEP) Division of
Flammable Liquids 29 CFR 1910.106
Flammable Liquids 29 CFR 1910.106 OSHA s Directorate of Training and Education These materials were developed by OSHA s Directorate of Training and Education and are intended to assist employers, workers,
Section 6 4.3 Ambulance Service Charge. Effective July 1, 2014, the following bundled ambulance service charges shall apply:
CITY OF ATTLEBORO, MASSACHUSETTS HEADQUARTERS OF THE FIRE DEPARTMENT 100 UNION STREET ATTLEBORO, MASSACHUSETTS 02703 PHONE 508-222-2324 FAX 508-223-2068 SCOTT T. LACHANCE FIRE CHIEF Section 6 4.3 Ambulance
ADMINISTRATIVE SERVICES MANUAL
Purpose Responsibilities Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and injuries. To minimize risk to life and properly, the requirements of
How To Make Calcium Carbide
11.4 Calcium Carbide Manufacturing 11.4.1 General Calcium carbide (CaC 2 ) is manufactured by heating a lime and carbon mixture to 2000 to 2100 C (3632 to 3812 F) in an electric arc furnace. At those temperatures,
Chapter 3 The fuel effect: What is being burned matters
Chapter 3 The fuel effect: What is being burned matters There are three types of fuel used in residential and commercial boilers for heating: Residual fuel oil Distillate fuel oil Natural gas In general,
LIST OF STANDARD CLASSIFICATION CODES (SCC) Emission Statement Report Of Actual Emissions
LIST OF STANDARD CLASSIFICATION CODES (SCC) Emission Statement Report Of Actual Emissions 1 ORGANIZATION OF SCCs The four levels of source descriptions for SCCs are associated with the first 1, 3, 6, and
Flammable and Combustible Liquids. Slide 1 (of 23)
Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids
APPLICATION FOR DRY CLEANERS PROGRAM (THIS APPLICATION IS FOR A CLAIMS MADE POLICY)
APPLICATION FOR DRY CLEANERS PROGRAM (THIS APPLICATION IS FOR A CLAIMS MADE POLICY) INSTRUCTIONS 1. If space is not sufficient to fully answer the questions, please attach additional pages. 2. This form
Efficiency Options for Thermal & Catalytic Oxidizers
Efficiency Options for Thermal & Catalytic Oxidizers Kyle Momenee / Application Engineer Anguil Environmental Systems Inc. www.anguil.com EPA Roundtable March 25 th, 2009 1 Background-Anguil Environmental
Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers
For Industrial Heating Equipment and Boilers Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC
SPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC)
SPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC) UNIVERSITY RISK MANAGEMENT Occupational and Health Programs 19 Hagood Avenue, Suite 908 Charleston SC 29425 843-792-3604 Revised: June 2015 Spill
HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids
Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
4.1 Dry Cleaning. 4.1.1 General 1,2
4.1 Dry Cleaning 4.1.1 General 1,2 Dry cleaning involves the cleaning of fabrics with nonaqueous organic solvents. The dry cleaning process requires 3 steps: (1) washing the fabric in solvent, (2) spinning
ATTACHMENT B California Energy Commission Air Quality Self-Certification Checklist for Simple-Cycle Gas Turbine Generation Units
ATTACHMENT B California Energy Commission Air Quality Self-Certification Checklist for Simple-Cycle Gas Turbine Generation Units License Application for: [ X ] New Emissions Unit(s) at a New Stationary
Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)
Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil) References: Comm 10 2009 EDITION / NFPA 30 2008 EDITION ITEM DESCRIPTION Comm 10 / NFPA General
Nonrenewable Natural Gas. Natural Gas Basics. How Was Natural Gas Formed?
Did You Know? Because natural gas is colorless, odorless, and tasteless, mercaptan (a chemical that smells like sulfur) is added before distribution, to give it a distinct unpleasant odor (it smells like
How To Calculate Cost Of An Eco-Friendly Building
THE ECONOMICS OF LEED FOR EXISTING BUILDINGS FOR INDIVIDUAL BUILDINGS 2008 EDITION A WHITE PAPER BY LEONARDO ACADEMY INC. Revised February 2, 2009 APRIL 21, 2008 THIS WHITE PAPER SPONSORED BY JOHNSON CONTROLS
Clean Abundant and Economical Natural Gas
Clean Abundant and Economical Natural Gas 1 Fast fill/public Access CNG Station Typical costs are $1.5 million per station as shown 2 Time Fill Private CNG Station Time Fill Post Dispensers K rail Compressors
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:
Summary of Environment and Social Impacts for Activates Associated with Petroleum Refining and the Storage of Petroleum Products
Sub-sectoral and Social Guidelines Summary of and Social Impacts for Activates Associated with Petroleum Refining and the Storage of Petroleum Products Introduction: The following table should be read
CHAPTER 62-740 PETROLEUM CONTACT WATER
CHAPTER 62-740 PETROLEUM CONTACT WATER 62-740.010 Declaration of Intent (Repealed) 62-740.020 Applicability 62-740.030 Definitions 62-740.040 General 62-740.100 Management Practices for Producers of PCW
New York State Department of Environmental Conservation 625 Broadway, Albany, NY 12233 www.dec.ny.gov. Environmental Self Audit For Small Businesses
New York State Department of Environmental Conservation 625 Broadway, Albany, NY 12233 www.dec.ny.gov Environmental Self Audit For Small Businesses Disclaimer The materials in this document are intended
5.2 Transportation And Marketing Of Petroleum Liquids 1-3. 5.2.1 General
5.2 Transportation And Marketing Of Petroleum Liquids 1-3 5.2.1 General The transportation and marketing of petroleum liquids involve many distinct operations, each of which represents a potential source
Standard Operating Procedure
Standard Operating Procedure FLAMMABLE LIQUIDS This standard operating procedure (SOP) is intended to provide general guidance on how to safely work with flammable liquids. This SOP is generic in nature
Safe Operating Procedure
Safe Operating Procedure (Revised 3/14) ABOVEGROUND PETROLEUM STORAGE TANKS INTRODUCTION Aboveground storage tanks (ASTs) are used to store petroleum products at several UNL locations. For example, ASTs
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No
General Inspection FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS 1. All Floors (inspect from top floor to basement): Yes are fire exits and directional signs properly illuminated? is the emergency
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
Hazardous Waste Determination and Management Plan
Hazardous Waste Determination and Management Plan Prepared By: Triumvirate Environmental Developed: November 2014 Updated: Program Approval Associate Vice President of Public Safety & Administrative Services
BP WIND ENERGY POLICIES AND PROCEDURES
BP WIND ENERGY POLICIES AND PROCEDURES Document Control Details 1.0 Purpose/Scope 1.1 This procedure provides the minimum requirements to be followed for the storage of flammable or combustible materials
Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:
Autoclave Safety Purpose: Sterilization refers to the complete killing of all living organisms, including spores. Common sterilization techniques include the application of wet heat, dry heat, chemicals,
(Adopted December 1, 1978)(Amended July 8, 1983)(Amended November 6, 2009) (Amended September 5, 2014)
(Adopted December 1, 1978)(Amended July 8, 1983)(Amended November 6, 2009) (Amended September 5, 2014) RULE 1111. REDUCTION OF NO x EMISSIONS FROM NATURAL-GAS- FIRED, FAN-TYPE CENTRAL FURNACES (a) (b)
NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC (Sections 63.11110 63.
MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY (DEQ), OFFICE OF ENVIRONMENTAL ASSISTANCE NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC
RESIDENTIAL AND COMMERCIAL/INSTITUTIONAL NATURAL GAS AND LIQUEFIED PETROLEUM GAS (LPG) COMBUSTION
RESIDENTIAL AND COMMERCIAL/INSTITUTIONAL NATURAL GAS AND LIQUEFIED PETROLEUM GAS (LPG) COMBUSTION DESCRIPTION This source category covers air emissions from natural gas and liquefied petroleum gas (LPG)
Dip Tanks. RS 1030 (9/13) 2013 Nationwide Mutual Insurance Company Page 1 of 9 All Rights Reserved
This Data Sheet discusses the fire and explosion hazards associated with dip tanks as well as several fire prevention tactics. EPA information is included as an added benefit only. The information from
Energy Audit Data Collection Form
SAVING ENERGY IN COMMERCIAL BUILDINGS Energy Audit Data Collection Form Site Data Building Name Address Building Square Footage (ft 2 ) Age of Building (years) Date of Last Major Renovation Purpose of
POTENTIAL TO EMIT SUMMARY FIBERIGHT, LLC HAMPDEN, MAINE
POTENTIAL TO EMIT SUMMARY FIBERIGHT, LLC HAMPDEN, MAINE s (Ton/Year) Thermal Flare Oxidizer Boiler#1 Boiler #2 Scrubber #1 Scrubber #2 Total Carbon Monoxide (CO) 6.91 2.90 43.59 24.90 78.3 Oxides of Nitrogen
A SELF-EVALUATION CHECKLIST of BEST PRACTICES for AUTO REFINISH SHOPS and SCHOOLS
A of BEST PRACTICES for AUTO REFINISH SHOPS and SCHOOLS www.epa.gov/dfe/pubs/projects/auto/ WHAT IS THE DESIGN FOR THE ENVIRONMENT (DFE) AUTO REFINISH PROJECT? The DfE Program has been working with the
Pollution Prevention And Best Management Practices For Dry Cleaners Operating In Broward County
FORWARD In 1991, the Broward County Environmental Protection and Growth Management Department, who was then known as the Department of Natural Resource Protection (DNRP), initiated the development of Pollution
healthy homes assessment
healthy homes assessment Date of Inspection: Inspector s Name: Agency: Address of Property: Resident s Name: Phone Number: Primary Reason for Visit: Asthma Lead Poisoning Voluntary Referral Other: GENERAL
Hot Water Heating: Technologies and Use
Hot Water Heating: Technologies and Use Skip Hayden Integrated Energy Systems CanmetENERGY Better Buildings by Design 2010 Burlington Vermont February 2010 Natural Resources Canada Ressources naturelles
COMMONWEALTH OF MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION 310 CMR 7.00 AIR POLLUTION CONTROL REGULATIONS
COMMONWEALTH OF MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION 310 CMR 7.00 AIR POLLUTION CONTROL REGULATIONS 310 CMR 7.00 APPENDIX B U EMISSION BANKING, TRADING AND AVERAGING 310 CMR 7.00: Appendix
Half the cost Half the carbon
Half the cost Half the carbon the world s most efficient micro-chp What is BlueGEN? The most efficient small-scale electricity generator BlueGEN uses natural gas from the grid to generate electricity within
BPC Green Builders. Green building for new and existing homes. Health Comfort Energy
BPC Green Builders Green building for new and existing homes Health Comfort Energy Mechanical Systems Installed HVAC Systems Primary energy source large, roof mounted, solar thermal array (AET flat plate)
Commercial Kitchen Fire Safety
Commercial Kitchen Fire Safety Commercial grade kitchens are a common feature found in many churches today, as religious institutions are providing meals for daycares, soup kitchens, meals on wheels and
THE PROPANE TECHNICAL POCKET GUIDE
THE PROPANE TECHNICAL POCKET GUIDE The Propane Technical Pocket Guide The Propane Technical Pocket Guide is intended to be a general reference of information on preparing for the installation of propane
DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY
DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY FREQUENTLY ASKED QUESTIONS (FAQ) Question: Do fuel tanks fall under the requirements of Directive 055? No. For storage of fuels (e.g.,
FIRE PREVENTION PLAN
FIRE PREVENTION PLAN 1 FIRE PREVENTION PLAN OSHA s Fire Prevention Plan regulation, found at 29 CFR 1910.38(b) and 29 CFR 1926.24, requires Northern Clearing, Inc. to have a written fire prevention plan