PVC Pipe for Trenchless Installation
|
|
|
- Steven Hardy
- 10 years ago
- Views:
Transcription
1 PVC Pipe for Trenchless Installation Design & Installation Guide 1
2 CONTENTS PAGE NUMBER Introduction 3 Applications 3 Features and Benefits 3 Product Data 4 Material Properties 4 Pipe Stiffness 4 Standards & Testing 4 Product Range 4 Pipe Fittings 4 Rubber Ring Seals 4 Colour & Markings 4 Pipe Dimensions 4 Hydraulic Design 5 Structural Design 5 Pipe Grouting 5 Handling and Storage 6 General Installation Guidelines 7 Pipe Jointing Lubricant 7 Strap Wrenches 7 Pull Heads 7 Bore Hole & Drill Mud 7 Tensile & Compressive Loads 8 Radius of Curvature 8 Installation 8 Horizontal Directional Drilling (HDD) 10 Reaming 12 Pipe Bursting, Static & Hydraulic 13 Pilot Tube Micro Tunnelling & Horizontal Auger Boring 15 Slip Lining 16 Field Testing 17 Frequently Asked Questions 18 2
3 1.0 INTRODUCTION Iplex Pipelines has developed Restrain PVC Sewer Pipe specifically for gravity sewer applications using trenchless techniques, for the installation, repair or replacement of underground infrastructure. Restrain is a rubber ring jointed, SN16 PVC-U sewer pipe, utilizing a threaded spigot and low profile threaded socket, which provides axial end load restraint. Figure 1 Typical joint arrangement showing the rubber sealing ring, threaded spigot and low profile threaded socket. 1.2 Applications Iplex Restrain Sewer Pipe has been designed for gravity sewer applications and is suitable for installation by a range of trenchless methods, including: Horizontal Directional Drilling (HDD) Pipe Reaming (PR) or Pipe Eating (PR-PE) Pipe Bursting Static (PB-ST) Pipe Bursting Hydraulic (PB-HY) Pipe Bursting Slitting (PB-SL) Pilot Tube Micro Tunnelling (PTMT) Horizontal Auger Boring (HAB) Slip Lining (SL) The following table provides a summary of features and benefits. Table 1 Features and benefits of Restrain PVC Sewer Pipe Feature Benefit Threaded socket & spigot joint Pipe lengths can be customised to suit the installation or project requirements Compatible with standard DWV PVC Sewer fittings to AS/NZS 1260 Bi-directional installation capability Rubber sealing ring performance conforming to AS/NZS 1260 Complies with AS/NZS Independently certified in accordance with the test requirements of AS/NZS StandardsMark licence number SMKP Manufactured from PVC-U Manufactured in stiffness class SN16 Allows axial restraint during installation using trenchless methods Enables use with a range of installation technologies or site requirements Allows simple connection to maintenance chambers and service laterals Pipe can be pushed or pulled into place to suit installation methodology Eliminates the risk of leakage and root intrusion Product meets industry manufacturing and performance standard Compatible with standard PVC-U drainage fittings Provides the structural performance of SN16 RESTRAIN PVC Sewer Pipe is not suitable for use with pneumatic or concussive pipe bursting equipment. It is also not suitable for pipe ramming or impact moling. 1.3 Features and Benefits The threaded spigot and socket provides axial end load restraint to ensure joint integrity during installation using trenchless techniques. Iplex Pipelines NZ Ltd retain the intellectual property rights for Restrain pipe; New Zealand Patent No Iplex Restrain PVC Sewer Pipe is compatible with both solvent weld and rubber ring jointed DWV PVC-U Sewer Pipe and fittings complying with AS/NZS Restrain is available in a range of pipe lengths from 1m to 6m to suit project and site requirements. The Restrain socket is low profile, i.e. has a smaller outside diameter than a conventional SC style PVC pipe socket. 3
4 2.0 PRODUCT DATA Iplex Restrain is a DWV sewer pipe with a threaded spigot and socket assembly, with a rubber sealing ring. Restrain is manufactured in accordance with AS/NZS 1260 PVC-U pipe for drain, waste and vent applications. 2.1 Material Properties Restrain is manufactured from PVC-U (unplasticised polyvinyl chloride). The properties listed in Table 2 are typical for PVC-U Sewer Pipes. Table 2 Mechanical Properties for PVC-U Sewer Pipe Property Value & Unit Density 1450 kg/m 3 Ultimate tensile strength 52 MPa* Compressive strength 66 MPa* Ring Bending Modulus (3min) 3200 MPa Ring Bending Modulus (50 yr) 1400 MPa Hardness (Shore) 85 (ASTM D2240) Hardness (Brinnell) at 23 C Poisson s Ratio 0.38 Coefficient of linear thermal 7.0 x 10-5 /m/m/ C expansion *Refer Table 5 for maximum allowable axial loads for Restrain For more technical specifications and chemical resistance information please refer to the Iplex website or contact an Iplex Pipelines Engineer. 2.3 Pipe Stiffness All Restrain PVC Sewer Pipe is manufactured with a minimum pipe ring bending stiffness of N/m.m and is classified as SN16, to AS/NZS Standards & Testing Iplex Pipelines NZ Limited is certified by Licence No. QEC4169 as satisfying the requirements of ISO 9001: 2008 Quality Management Systems - requirements. Iplex Restrain is certified by StandardsMark Licence No. SMKP20184 as conforming to AS/NZS 1260:2009 PVC-U pipe and fittings for drain, waste and vent application. 3.0 PRODUCT RANGE Restrain Sewer Pipe is available in nominal diameters DN100, DN150, DN225 and DN300. Restrain is available in lengths ranging from 1m to 6m to suit project specific and/or site requirements. The length of the pipe is generally a function of the method of installation and site space requirements. 3.1 Pipe Fittings Restrain PVC Sewer Pipe is compatible with standard PVC-U sewer pipes and fittings for both solvent weld and rubber ring joints. A list of fittings is available from the Iplex Product Catalogue. 3.2 Rubber Ring Seals The rubber ring seal is supplied loose and should be stored to ensure that they are not damaged. The rubber ring seal should be placed in the pipe spigot groove and lubricated with silicone spray during the pipe jointing process. (Refer Section 8.) 3.3 Colour & Markings Restrain Sewer Pipe is manufactured in a light grey colour with a semi gloss finish which is opaque and flawless. Iplex Restrain Sewer pipes are repetitively marked in accordance with AS/NZS1260 PVC-U pipes and fittings for drain, waste and vent application. Markings include: Manufacturers name and brand name Australian Standard number StandardsMark Licence No. Nominal Pipe Size Pipe Type Pipe Class Date of manufacture Manufacturer s code 3.4 Pipe Dimensions Restrain PVC Sewer Pipe is available in lengths ranging from 1m to 6m to suit specific project and/or site requirements. The length of the pipe is generally a function of the method of installation and site space requirements. The product is specified by overall length in order to facilitate on site requirements. The effective length of the pipe is the overall pipe length plus dimension A as shown in Table 3. Other typical pipe dimensions are shown in this table. Table 3 Restrain Pipe Dimensions Pipe DN Mean Pipe OD (mm) Socket OD (mm) SN Mean ID (mm) Effective length converter A mm mm mm mm 4
5 4.0 HYDRAULIC DESIGN Where a sewer pipeline is flowing full under gravity conditions the method of determining the pipe size is similar to that used for pressure pipes. The grade of the pipeline gives the allowable head-loss but special attention should be given to the effect of entry and exit losses at structures such as manholes as these may be significant. For pipes flowing full, full capacity can be calculated similarly as for pressure pipes. Contact Iplex Pipelines for Restrain Flow Capacity information. 5.0 STRUCTURAL DESIGN Restrain Sewer Pipes are defined as flexible pipes. Flexible pipes are designed to deflect slightly under load and hence utilise surrounding soil strength, as well as pipe stiffness, to oppose the vertical loads. Structural design of Restrain Sewer Pipes should conform to the requirements of AS/NZS Buried Flexible Pipelines Structural Design. Contact Iplex Pipelines for more information on structural design of trenchless installations. Pipe Grouting Where it is necessary to pressure grout the annulus between Restrain pipe and a host pipe during slip lining, it is important to ensure that the grout is introduced so as not to damage the Restrain sewer pipe. The grout must be introduced into the annulus as evenly as possible and must not exceed the Restrain pipe s maximum safe grouting pressure (refer Table 4). Table 4 Maximum Safe Grouting Pressure (factor of safety = 2.5) Pipe DN Maximum Safe Grouting Pressure (kpa) It is strongly recommended to cap off and fill the Restrain pipe with water prior to grouting to reduce the effects of grouting pressure and heat of hydration of the grout during curing. It may be possible to stage the grouting process in two or three lifts allowing the grout to solidify in the annulus to the spring line before the top section is filled. 5
6 6.0 HANDLING AND STORAGE Whilst Restrain Sewer Pipes are easy to handle, careless handling can cause unnecessary damage to the pipe and/ or joints. Pipes and fittings should not be dropped or thrown onto hard surfaces or allowed to come into contact with hard sharp objects that could inflict deep scratches. PVC-U pipe should not be allowed to slide across sharp edges. Racks for long term storage are recommended and should preferably provide continuous support, however if this is not possible, supports of at least 75mm bearing width at 1m maximum centres should be placed beneath the pipes. Side restraints should be placed at centres not exceeding 1.5m and stacks should not exceed 1m in height. Wire slings or chains must not be used to lift pipes. Particular care should be taken to prevent any damage to the thread on the spigot and socket which may affect the axial capacity and/or the jointing process. 75mm bearing width 1m spacing maximum Figure 6.3 Typical loose pipes on bearers When unloading alongside excavated trenches it is recommended that pipes be placed on the opposite side of the trench from excavated material if it is safe to do so. Figure 6.1 Handling of bulk bundles Storage If pipes and fittings are to be stored outdoors for more than 12 months they should be protected in a manner that prevents heat build-up and allows ventilation. Hessian or white shadecloth have been shown to be good materials for this purpose. Rubber rings and silicone spray should be stored under cover until pipe laying commences. Pipes may be stacked on site providing the surface is level and free from loose stones and other sharp objects. Pipes should be stacked in layers with sockets placed so that they are not load-bearing. This can be achieved by stacking pipes with alternate layers of sockets facing in opposite directions. 1m or 7 layers maximum 1.5m Figure 6.2 Typical loose pipe storage on ground 6
7 7.0 GENERAL INSTALLATION GUIDELINES General Restrain Sewer Pipe can be installed by a number of trenchless methods. A brief description of some of these methods are: Horizontal Directional Drilling (HDD) Pipe Reaming (PR) or Pipe Eating (PR-PE) Pipe Bursting Static (PB-ST) Pipe Bursting Hydraulic (PB-HY) Pipe Bursting Slitting (PB-SL) Pilot Tube Micro Tunnelling (PTMT) Horizontal Auger Boring (HAB) Slip Lining (SL) 7.3 Pull Heads We recommend the use of a cone style pull head as shown in figure 7.3 for HDD, Pipe Bursting, Auger Boring and Micro Tunnelling installations. These pull heads are normally fabricated from mild steel plate or pipe. The pull head is connected to a Restrain socket starter pipe (2-3 pipe diameters long) fastened to the pull head with threaded rod or cross bolts as shown in figures 7.2 and 7.3 Allow one pipe diameter between the cross bolt centrelines and off set by 90 degrees. Contact our Technical Services Call Centre on for more information. Each installation method has its own unique installation technique, detailed installation instructions by method are reported later in Section 8 of this manual. 7.1 Pipe Jointing Lubricant Use only Gensil 601, CRC 808 or Rocol spray silicone lubricant or an Iplex approved equivalent for lubrication of the joint assembly prior to assembly. Figure 7.2 Typical DN150 Internal Pull Head The silcone lubricant is used to lubricate the thread and seal ring prior to jointing of the pipes. The silicone lubricant allows the ability to reverse the thread jointing process should the pipes need to be removed from the bore hole or installation pit. 7.2 Strap Wrenches Use strap wrenches with extended woven nylon webbing straps for pipe turning during assembly. Rigid, Hit or Super Ego brand or any Iplex approved equivalent are recommended. It is recommended that a strap wrench with an extended 1200mm long strap be used to successfully join DN225 and DN300 Restrain sewer pipe. The Rigid No 5 strap wrench product code #31345 is well proven. The extended strap is an after market purchase, any canvas fabricator or upholsterer can stitch the replacement strap together from 45mm wide woven fabric. Figure 7.3 Typical DN300 External Cone Style Pull Head 7.4 Bore Hole & Drill Mud The bore hole dimensions vary depending upon the installation methodology being used, native soil type, additives used to produce drilling mud, drill mud viscosity, reamer type/style and pipe diameter. The contractor or driller is responsible for determining their bore hole diameter and drill mud type before drilling commences. Drill mud is an important component of successful installations. (See figure 7.4.) It is used to stabilise the borehole, assist in the cutting process, cool down the transmitter, carry spoil out of the borehole and lubricate the borehole for reducing the frictional resistance of the product being pulled into the borehole. Figure 7.1 Rigid No. 5 Strap Wrench and replacement after market 1200mm extended strap Figure 7.4 Typical free flowing drill mud/lubricant 7
8 7.5 Tensile & Compressive Loads Restrain Sewer Pipe is able to be pushed or pulled through a bore hole or host pipe. The threaded spigot and socket provides axial restraint capability. Do not exceed the maximum allowable axial load parameters shown in Table 5. Step 2 Unpack and thoroughly inspect all Restrain Sewer Pipes to ensure the threads, seal rings and the joint assemblies are clean, undamaged and free of dirt or grit before beginning assembly. Table 5 Pipe DN SN Maximum Allowable Axial Load Tensile Compression (kn) (KG) (kn) (KG) Radius of Curvature Restrain Sewer Pipe must be axially aligned with the host hole or host pipe at the point of entry. Some curvature back from the host hole/pipe is permitted. The minimum radius of curvature is based on 300 x outside diameter as detailed in Table 6. Table 6 Pipe DN Pipe OD (mm) Minimum Radii of curvature (m) Step 3 Place the seal ring in the groove (the last groove from the end of the pipe). The crown of the seal ring should be facing outwards. Carefully stretch the seal ring into the seal ring groove, tensioning the seal ring as you go by running your finger between the seal ring and the pipe in a circular motion around the pipes spigot/seal ring groove. 8.0 Installation Step 1 Place a temporary wind up or pneumatic test plug inside the socket end of the first Restrain pipe being installed. This prevents the new Restrain pipe barrel from being invaded by drill mud or ground water, allowing easier assembly during joining. Step 4 Lubricate the spigot thread, the seal ring, the socket thread and the lead into the socket. 8
9 Step 5 Align the clean spigot with the socket in a straight line. Ensure there is a smooth initial engagement. Do not cross thread. Use temporary support blocks if required. Step 8 Apply the strap wrenches to both the spigot and socket and screw up pipe until the seal ring completely disappears up into the mouth of the socket and the joint firmly resists further tightening. Do not overtighten. Spigot end machine mark Spigot thread Step 6 Align thread start arrows and initially turn the spigot by hand in a clock-wise direction to engage the first few threads. Ensure the pipe barrel is supported. The first thread engagement and the first few turns should be smooth and free of binding. Seal ring groove Step 9 Completed Restrain TM joint assembly with spigot end machine mark not visible. Step 7 Continue to hand screw the spigot into the socket as far as it will easily go, or up to where seal ring engages into the socket. Note: A Restrain C Wrench assembly tool may be required for DN300 Restrain Sewer Pipe due to the higher rotational forces required. The Restrain C Wrench is sometimes useful when working in confined spaces or between trench shields. 9
10 8.1 Installation Guidelines Horizontal Directional Drilling (HDD) Figure 8.1 Typical cartridge style HDD pull-back. Figure 8.2 Typical HDD cartridge style pull-back within a 1.8m diameter x 4.5m deep manhole structure installing DN300 x 1m Restrain Sewer Pipe Restrain has been installed in many locations throughout New Zealand. Typical shots of 80 to 100m are common with the longest known drill-shot to be 190m completed in one continuous pull-back. Restrain Pipe lengths vary depending upon geography, native soils, site layout and installation pit or manhole/chamber dimensions. Drillers have installed Restrain Sewer Pipe in lengths from 1m to 6 metres. 3.6m pipe-lengths correspond with most HDD Drill Rod lengths. Fig show cartridge style pull-backs being completed. Here, pipe strings could not be employed owing to limited space available on site. Step 1 Before you arrive on site determine the dimensions of your installation pit then order Restrain Sewer Pipe to suit your installation methodology. This may result in the selection of 6m pipe-lengths for a normal pipe-string or cartridge style HDD installation or you may choose 1m lengths or less if you plan to drill to a new or existing manhole structure completing pipe jointing within tight confined spaces. Some HDD operators order their pipe made to the same length as their HDD drill rods (usually 3.6m), this allows jointing to occur during drill rod changes and reduces your work site foot print as a pipe-string may or may not be required. Figure 8.3 Typical HDD cartridge style pull-back within trench shields, 7m deep. DN225 x 3m Restrain Step 2 Ensure tools and equipment are available, tools and equipment are detailed in section 7 of this manual. Step 3 Once on site, excavate installation pits. Ensure the installation pits are 1-2 pipe diameters below the new pipe invert. Figure 8.4 Typical HDD cartridge style pull-back between trench shields at a depth of 4.5m. DN150 x 6m Restrain 10
11 Step 4 Select a reamer style/type to suit your native soils, drill mud type/viscosity and Restrain Sewer Pipe outside diameter. Recommended reamer diameter guidelines are listed below in Table 7. Typical Sand Reamers Table 7 Pipe Diameter DN100 & DN150 DN225 & DN300 Reamed Diameter Pipe Diameter + 100mm Pipe Diameter x 1.5 The driller is responsible for selecting the borehole diameter and reamer type/size and drilling mud type or viscosity. Some typical reamer types are illustrated on the right. Drilling fluids are an important component of the HDD process. They are used to stabilize the borehole, assist in the cutting process, cool down the transmitter, carry the spoil out of the borehole, and lubricate the borehole for reducing frictional resistance of the product pipe. Typical Clay Reamers Warning: If the HDD drill rig pressure gauge suddenly increases, cease pull back IMMEDIATELY to avoid hydro-lock, buckling of the pipe and/or other mechanical breakages. Check water flow, drill mud flow, drill mud viscosity and or mix. Consider backing out the reamer reversing the Restrain jointing procedure. Check for bore hole collapse. Proceed with precaution. Step 5 Begin reaming or pull-back, follow the installation steps within Section 8.0. Step 6 Connect new sewer laterals into Restrain Sewer Pipe using a 3 way, plain ended wye junction or with a Restrain Quick Fit Saddle as illustrated in Figure 8.6. Traditional PVC fittings are used to complete the final connections. Typical Cobble Reamers Figure 8.5 Plain ended wye junction. Figure 8.6 Restrain Quick Fit Saddle. 11
12 8.2 Installation Guidelines Reaming Step 4 Attach reaming head and Restrain starter pipe using a swivel bearing. Figure 8.7 Typical reaming or pipe eating using a traditional Horizontal directional drill. Restrain has been installed using reaming methods. Reaming or Pipe Eating uses a traditional HDD rig where the drill rods are inserted inside existing earthenware pipes. A reaming head is connected prior to the new Restrain Sewer Pipe. Typical reams between manholes of up to 100m have been completed. Restrain Pipe lengths may vary however 6m lengths are most common. Step 5 Follow the installation steps within section 8.0 of this manual. Step 6 Proceed with the back reaming process pulling the new pipe into position. Step 1 Before you arrive on site determine the dimensions of the installation pits then order Restrain Sewer Pipe to suit installation pit dimensions. This may result in the selection of 6m pipe-lengths for a normal pipe-string or shorter lengths for a cartridge style deep pit ream. Step 2 Once on site excavate entry, exit and a small pit at each house lateral connection. Ensure the entry and exit pits are 1-2 pipe diameters below the invert of the old host pipe. Step 3 Introduce drill rods from a traditional HDD rig into the existing host pipe. Step 7 Connect existing house laterals using a 3 way, plain ended wye junction connecting into the main in place with traditional PVC slip couplers, bends and ceramic to PVC adaptors if required. 12
13 8.3 Installation Guidelines Pipe Bursting, Static & Hydraulic Typical Pipe Burst Heads & Mandrills Figure 8.8 Typical Static Hydraulic Pipe Bursting installation DN225 x 3m Restrain Sewer Pipe Restrain has been installed in many locations throughout New Zealand using Static/Hydraulic Bursting methods, typical burst lengths of m are common. Restrain Pipe lengths may vary depending upon installation pit or manhole/chamber dimensions. One of the deepest installations was completed in Auckland city during 2011 where 750mm lengths of DN300 Restrain Sewer Pipe was installed within existing 1050mm diameter concrete manhole structures at depths of up to 8m. The largest PB-HY upsize completed in a single pass using Restrain Sewer Pipe was completed with a TT (Tracto - Technik) 800g hydraulic PB rig, where existing DN150 steel reinforced concrete sewer pipe was upsized three sizes, pulling in DN300 Restrain Sewer Pipe behind the bursting head. Figure 8.9 Typical steel wheel or blade type bursting heads. Figure 8.10 Typical External Cone Style Bursting Head. Upsize of existing 100mm CI pipe with new PVC pipe. Bursting mandrill types will vary depending upon the host pipe type that you intend to replace. When replacing traditional materials such as Concrete, Clay and AC a bursting head as illustrated in Figure 13.0 is normally used, for Cast Iron and Polyethylene host pipe replacements a blade mandrill is installed ahead of the bursting head. Steel pipe replacement requires extreme hydraulic forces with specialist roller or wheeled mandrills, leading the bursting head. Step 1 Before you arrive on site determine the dimensions of installation pit then order Restrain Sewer Pipe to suit. This may result in the selection of pipe lengths measuring between 1 & 6m pipes for normal pipe-string or cartridge style PB installations. Step 2 Ensure tools and equipment are available, tools and equipment are detailed in Section 7. Figure 8.11 Typical External Bursting Head. DN300 Restrain Sewer Pipe. 13
14 Step 3 Once on site excavate installation pits and or lateral connections. Ensure the installation and receiving pits are 1-2 pipe diameters below the existing host pipe invert. Step 9 Once your new Restrain Sewer & lateral pipes are in place, connect sewer laterals using a 3 way, plain ended wye junction. or a Restrain Quick Fit Saddle, as illustrated in Figure Traditional PVC fittings are used to make the final connections. Figure 8.12 Figure 8.13 Installation pit Receiving pit Step 4 Select a mandrill or expander to suit the existing host pipe material. Allow for over expansion for a successful pull in. Over expansion will vary depending upon on factors including soil type, pipe diameter, pipeline length and tidal activity. Figure 8.16 Restrain Sewer, Lateral Pipe & Quick Fit Saddle installed. Do not exceed the maximum allowable axial loads detailed in Table 5. Step 5 Attach your Restrain socket starter pipe (refer Section 7.3) to the pull head. Step 6 In high water table applications a wind up test plug can be installed inside the socket end of your Restrain lead pipe. This will prevent ground water invading your new pipe. Step 7 Begin pull back. Follow the installation steps in Section 8.0. Step 8 Sewer laterals can be replaced using Restrain Sewer Pipe. 1, 2 or 3m pipes are often used for the pull back. The Hammer Head PB-30 Static PB unit is ideal for installing Restrain Sewer lateral pipe. Figure 8.14 Figure 8.15 Installation pit Receiving pit 14
15 8.4 Installation Guidelines Pilot Tube Micro Tunnelling & Horizontal Auger Boring Warning: The amount of over cut required to carry out the MT process depends upon factors including the type of soil, lubrication,, pipe size and line length, and is normally at least 20mm larger than the maximum pipe socket OD, or may be 30 to 50mm larger in rock or swelling clay. Do not exceed the maximum allowable axial load detailed in Table 5. Figure 8.17 Typical Micro Tunnelling installation. Pilot Tube Micro Tunnelling (PTMT) is a method of installing new pipes below ground, at depth, working with limited space, accurately installing a pipe behind a remotely controlled, steerable, guided auger boring machine. PTMT employs augers to transport the spoil out of the bore hole and a guidance system. Horizontal Auger Boring (HAB) when compared to PTMT, employs less complicated & less expensive equipment. HAB is widely used to install pipes and casings. Restrain Sewer Pipe has been installed using both techniques, the installation method is similar for PTMT and HAB. Figure 8.18 PTMT, DN225 x 2m Restrain Sewer Pipe, with auger section inserted. Step 1 Before you arrive on site determine what length of Restrain Sewer Pipe you will require. Pipe lengths are usually consistent with the length of the PTMT or HAB, auger casings. Some contractors have their pipe manufactured the same length as their augers or in multiples of 2, then order Restrain Sewer Pipe. Step 2 Ensure tools and equipment are available, tools and equipment are detailed in Sections 7.1 through to 7.6. Step 3 Attach your Restrain socket starter pipe (Section 7.4) to the lead auger. Insert augers inside the pipe sections (refer Figure 8.18). Figure 8.19 PTMT using DN225 x 2m Restrain Sewer Pipe. Installed at 0.04% grade. Step 4 Begin pilot tube installation and MT the bore hole. Add your next auger then follow the jointing procedure in Section 8.0, pushing Restrain Sewer Pipe into place. 15
16 8.5 Installation Guidelines Slip Lining Step 7 A proving plug should be pulled through the existing host pipe to cross check a successful installation. Step 8 Begin pull back, follow the installation steps within Section 8.0. Figure 8.20 Typical Slip Lining installation using DN150 x 6m Restrain Sewer Pipe. Slip Lining (SL) is a method of installing a new pipe by inserting (or slipping) Restrain Sewer Pipe inside a deteriorated host pipe. SL can be used to rehabilitate gravity sewer and stormwater pipelines however the decrease in the existing pipe s cross sectional area needs to be evaluated. Restrain provides a larger cross sectional area when compared with other thermoplastic pipe systems. Step 1 Check alignment, establish if the grade of the host pipe provides suitable fall for your new Restrain Sewer Pipe. Step 2 Gain approval from the asset owner to ensure they are satisfied with the existing pipe-grade. Figure 8.21 Assembling Restrain joint with strap wrench Step 9 Push or pull your first Restrain pipe into the host pipe. Step 10 Stabilise your new pipe within the host pipe. For short SL installations, concrete anchor blocks are poured at the entry and receiving pits. For longer SL installations, grouting of the new pipe into the host pipe may be required. (Refer Section 5.) Step 3 Before you arrive on site determine what length of Restrain Sewer Pipes are fit for use at the site. In most cases the contractor orders the longest pipe available, 6m lengths are common when installing via SL methods. Once pipe lengths are determined order Restrain Sewer Pipe. Step 4 Clean and prepare the host pipe for insertion. Step 5 Ensure tools and equipment are available, tools and equipment are detailed in Section 7. Step 6 Once on site excavate entry and exit pits ensuring your work platform is free from ground water. Ensure the entry and receiving pits are 1-2 pipe diameters below the existing host pipe invert. 16
17 9.0 Field Testing General The Restrain Sewer Pipe system may be field tested after installation, in accordance with the relevant parts of these industry Standards: New Zealand Standard NZS4404:2010 Land Development and Subdivision Infrastructure, Appendix C2 Non-pressure pipelines -field leakage testing, and Clause C2.2 Hydrostatic Test. Joint Australian / New Zealand Standards AS/NZS Design of Buried Flexible Pipelines Installation, Section 6 Field testing, and Appendix N Leakage testing for non-pressure pipelines AS/NZS2032 Installation of PVC Pipe and Fittings, Section 7.3 Testing of non-pressure pipelines Figure 9.0 Field Testing. DN150 Restrain Sewer Pipe. 17
18 10.0 Frequently Asked Questions Question 1 Can Restrain sewer pipe be used with traditional PVC drain, waste & vent pipe and fittings? Answer Yes, Restrain sewer pipe is fully compatible with PVC DWV pipe and fittings, manufactured to AS/NZS1260. Question 2 How do I test Restrain sewer pipe on site? Answer Restrain sewer pipe is tested in the same as traditional PVC pipe. Refer to Section 9. Question 3 Can I use solvent cement DWV fittings on Restrain sewer pipe? Answer Yes, Restrain sewer pipe has the same outside diameter as traditional PVC DWV pipe, and can be used with PVC DWV fittings designed for solvent cement jointing. Remove the threaded Restrain socket or spigot before assembling of the solvent cement joint. Question 4 What type of lubricant do I use when jointing Restrain sewer pipe? Answer We recommend CRC808 or Gensil 601 silicone spray lubricant. Question 5 Why can t I use standard rubber ring pipe lubricant on Restrain? Answer Standard pipe lubricant looses its slippery properties soon after the joint is made. Silcone lubricant remains slippery longer, which may allow you to unscrew the threaded joint should the installation need changes. Question 6 Why is a different pull head necessary? Answer Standard wind-up pull heads designed for PE pipe may not be suitable for Restrain, as the internal engagement grooves may not grip effectively into the dense PVC surface. Cross-bolt style pull heads, for internal or external use, are recommended for Restrain pipe, as shown in paragraph
19 10.0 Iplex Pipelines The Company Iplex Pipelines is a major Australasian manufacturer and distributor of a wide range of plastics based pipeline systems for the Civil, Mining, Plumbing, Irrigation, Gas, Telecommuniations and Electrical Cable conduit markets. One of the Fletcher Building Group of Companies, Iplex Pipelines is well placed for accessing the latest overseas products, technologies, and service initiatives and has become a recognised leader in plastics pipes and associated fittings, together with related water engineering expertise. Manufacturing and Standards Iplex Pipelines operates modern manufacturing facilities in New Zealand and every mainland Australian State. All factories operate under stringent requirements of local equivalents to international standard ISO Where applicable, Iplex products also have StandardsMark third party quality assurance accreditation. Sales and marketing teams are strongly supported by advanced technical, communication and distribution systems to ensure prompt and effective service. Products and Brands Iplex products and brand names in New Zealand include APOLLO PVC-O pressure pipes, RHINO PVC-M pressure pipes, NOVAKEY PVC-U pressure pipes and fittings, BLUE BRUTE PVC-U pressure pipes, NOVADRAIN DWV pipes and fittings, POLIPLEX polyethylene pressure pipes, RESTRAIN drillable PVC-U gravity sewer pipe, NEXUS subsoil drainage pipe and fittings and FARMTUFF culvert pipe. Markets and applications for the Iplex product range in New Zealand include water reticulation and transmission mains, sewerage reticulation and carrier mains, stormwater drainage, trenchless pipe systems, chemical and process water circuits, slurry and tailings pipe systems, drain, waste and vent plumbing, domestic hot and cold water plumbing, subsoil drainage systems, turf watering, stock watering, horticultural irrigation systems and broad acre irrigation systems. You can obtain further product or technical information by contacting Iplex Pipelines directly. Please refer to the back cover of this catalogue for contact details. IPLEX PIPELINES (NZ) LTD RETAIN THE INTELLECTUAL PROPERTY RIGHTS FOR RESTRAIN PIPE, NEW ZEALAND PATENT No IMPORTANT DISCLAIMER: THE INFORMATION, OPINIONS, ADVICE AND RECOMMENDATIONS CONTAINED IN THIS PUBLICATION ARE PUT FORWARD WITH THE MAIN OBJECT OF PROVIDING A BETTER UNDERSTANDING OF TECHNICAL MATTERS ASSOCIATED WITH PIPELINE INSTALLATION USING IPLEX PIPELINES. WHILST ALL REASONABLE CARE HAS BEEN MADE IN ENSURING THAT THE INFORMATION CONTAINED IN THIS PUBLICATION IS ACCURATE, THIS PUBLICATION SHOULD NOT BE USED AS THE ONLY SOURCE OF INFORMATION BY THE READER. REFERENCE SHOULD ALSO BE MADE TO ESTABLISHED TEXTBOOKS AND OTHER PUBLISHED MATERIAL, AND READERS SHOULD NOT RELY ON THE INFORMATION CONTAINED IN THIS PUBLICATION WITHOUT TAKING APPROPRIATE PROFESSIONAL ADVICE FOR THEIR PARTICULAR CIRCUMSTANCES. PIPES AND FITTINGS HAVE BEEN SHOWN AS TYPICAL CONFIGURATIONS, HOWEVER, IN SOME CASES PRODUCT DIMENSIONS MAY VARY OR BE CHANGED WITHOUT NOTICE. IN ALL INSTANCES, THE READER SHOULD CONTACT IPLEX PIPELINES FOR CLARIFICATION THAT THE SPECIFIC PRODUCT IS APPROPRIATE FOR THEIR CIRCUMSTANCES. - IPLEX PIPELINES NZ LIMITED. 19
20 NOVADRAIN & NOVACOR PVC DRAIN WASTE & VENT SYSTEMS POLIDRAIN POLYETHYLENE DRAINAGE SYSTEM SUPERSTORM & STORMFIT PVC STORMWATER DUCT SYSTEM NEXUS HI-WAY ROAD DRAINAGE SYSTEM NOVAKEY & BLUE BRUTE PVC-U PRESSURE SYSTEMS WHITE & BLUE RHINO HIGH IMPACT PVC-M PRESSURE PIPE APOLLO & APOLLOBLUE PVC-O PRESSURE PIPE NOVAFUSE FUSIBLE PVC PIPE BLUELINE & POLIPLEX POLYETHYLENE PRESSURE PIPE ALKATHENE LOW DENSITY POLYETHYLENE PIPE NOVATUBE HORTICULTURAL LATERAL TUBE GREENLINE, REDLINE, RURAL BLACK & BLACKLINE POLYETHYLENE PRESSURE PIPE PLASSON METRIC COMPRESSION FITTINGS NEXUS FLO, NEXUS COIL, NOVAFLO & NOVACOIL LAND DRAINGE SYSTEMS IPLEX EFFLUENT PIPE MEDIUM DENSITY POLYETHYLENE PIPE FARMTUFF & NEXUS CULVERT CULVERT PIPE POLIGAS POLYETHYLENE GAS SYSTEMS 2008 IPLEX PIPELINES (NZ) LIMITED. NEXUS, IPLEX, RESTRAIN, APOLLO, NOVAFUSE, NOVAFLO, FARMTUFF, NOVAKEY, POLIGAS, RHINO, REDLINE, POLYDRAIN, SUPERSTORM are registered trademarks of IPLEX PIPELINES (NZ) LIMITED. Iplex Pipelines NZ Limited. Call Centre - Phone: Fax: Web: Offices At: Auckland: Palmerston North: Christchurch: PO Box 13772, Onehunga, 2 Rockridge Avenue, Penrose. Private Bag 11019, 67 Malden Street. PO Box 16225, 22 Braeburn Drive, Sockburn. 20 Ver.07
PVC Pipe for Trenchless Installation
PVC Pipe for Trenchless Installation INSTALLATION GUIDELINES Ver. 2 CONTENTS PAGE NUMBER Installation Methods 1 General Installation Information 2 Horizontal Directional Drilling / Micro Tunneling / Pipe
Pipes and Fittings for Gravity Sewer Mains. SewerMAX
SewerMAX High resistance to tree root intrusion and groundwater infiltration lightweight for ease of installation low embodied energy for environmental benefits long service life Excellent chemical resistance
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION
SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION 1. SCOPE Pipe subsoil drains shall be constructed in accordance with this specification and in conformity with the lines, grades and cross-sections shown
TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe
TECHNICAL NOTE Culvert Sliplining and Lining of Casings with HPPipe TN 5.14 February 2010 Introduction It may be at times necessary, in an aging infrastructure, to rehabilitate drainage and sanitary lines
Pipeline Replacement using Relining
Pipeline Replacement using Relining Mark Heathcote, March 2006 Relining of old pipeline systems is becoming an increasingly attractive option to asset owners and operators as an effective alternative to
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
TRENCHLESS TECHNOLOGY GUIDELINES CLOSE FIT THERMOPLASTIC LINING
TRENCHLESS TECHNOLOGIES RESOURCE CENTRE TRENCHLESS TECHNOLOGY GUIDELINES SECOND EDITION CLOSE FIT THERMOPLASTIC LINING NEW VERSION AUGUST 2005 1. OVERVIEW The use of liners that are deliberately deformed
The Manitoba Water Services Board SECTION 027030 Standard Construction Specifications September 2013 Page 1 of 21
September 2013 Page 1 of 21 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of sewers including: the supply and installation of pipe, saddles, tees,
Installation of Large Diameter Buried Pipes
Installation of Large Diameter Buried Pipes Sullivan (Sully) Curran P. E., Executive Director I. Introduction and Scope There is an ongoing need to provide designers, specifiers, engineers, consultants
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe
TECHNICAL NOTE Lining of Casings with SaniTite HP Pipe TN 5.18 October 2015 In sanitary sewer, it is often necessary to use trenchless technology methods to install a casing pipe under high volume roads,
Appendix A: Acceptable pipe and fitting materials
Watercare Services Limited Water and Code of Practice Content from the NZS 4404:2010 Land development and subdivision infrastructure has been reproduced for use in the Infrastructure Design s Manual for
SPR PE Steel Reinforced Liner
ENGINEERED SOLUTIONS SPR PE Steel Reinforced Liner Reline Done Right Contech is your single source for rehabilitation of sanitary & storm sewers, culverts and bridges. Contech Engineered Solutions has
The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
Section 33 0200- Page 1 of 4 PART 1 - GENERAL 1.1 DESCRIPTION OF WORK The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.
DIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
Sewer Line Rehabilitation
1.0 GENERAL 1.1 DESCRIPTION: This specification shall cover the rehabilitation of existing sanitary sewers using the GRUNDOCRACK PIPE BURSTING SYSTEM. Pipe bursting is a system by which the pneumatic bursting
Section 2100-Trenching and Tunneling
SECTION 5200 - STORM SEWER PART 1 - GENERAL 1.01 SCOPE: This Section covers installation of storm sewer mains and culverts. Topics include permits and fees, trench widths, pipe laying, bedding, initial
SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)
SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO) 1 Intent: The intent of trenchless sewer pipe Insertion is to rehabilitate the existing sewer
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE
SECTION 33 11 00.11 POLYVINYL CHLORIDE (PVC) PIPE PART 1: GENERAL 1.01 SECTION INCLUDES PVC pressure pipe and fabricated fittings in nominal sizes 4-inches through 12-inches with cast iron pipe equivalent
TG 105 ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS TECHNICAL GUIDELINE. Manager Asset Management SOUTH AUSTRALIAN WATER CORPORATION
TG 105 SOUTH AUSTRALIAN WATER CORPORATION TECHNICAL GUIDELINE ALLOWABLE PIPE SIZE, CLASS AND MATERIALS FOR WATER MAINS Issued by: Manager Asset Management Issue Date: SA WATER 2007 This document is copyright
Carlon Bore-Gard and Boreable Multi-Gard Raceway
Carlon Bore-Gard and Boreable Multi-Gard Raceway Bore-Gard Schedule 40 Bore-Gard Schedule 80 Boreable Multi-Gard Type 40 www.carlonsales.com 231 Bore-Gard Trenchless Raceway Carlon Bore-Gard Trenchless
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
Royal Seal Gasketed Sewer Pipe
Royal Seal Gasketed Sewer Pipe Royal Seal Gasketed Sewer Pipe Royal Seal gasketed sewer pipe with our specially designed Double Seal Locked-In (DSLI ) gasket is an extremely durable pipe with a leak proof
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer
Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer The user may choose to adopt part or all of this Model Specification; however, the user should ensure that all parts
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
SECTION 221413 FACILITY STORM DRAINAGE PIPING
SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
Wastewater Capital Projects Management Standard Construction Specification
CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 10.1 Precast Concrete Pipe 10.1.1 General This section covers material requirements,
ENGINEERED SOLUTIONS. A2 Liner Pipe for Trenchless Technology
ENGINEERED SOLUTIONS A2 Liner Pipe for Trenchless Technology A2 Liner Pipe Restores Deteriorated Sewers Cost-Effective Rehabilitation The increasing rate of sanitary and storm sewer deterioration requires
A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.
PART 1 GENERAL 1.1 SCOPE A. This item shall include the work necessary for the installation of storm sewer line construction. B. Reference Section 3800 Trenching and Backfill and the General Conditions,
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe
Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe 1. GENERAL The following supplemental sewer main specifications are intended to address the installation of high-density polyethylene
LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM
North American Society for Trenchless Technology (NASTT) No-Dig Show 2010 Chicago, Illinois May 2-7, 2010 Paper D-4-02 LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE
SECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe
Pipe bursting provides viable alternative for rehab work By Greg Key, U.S. Pipe As the Environmental Protection Agency tightens groundwater quality regulations, old leaking sewers lines made of pipe clay,
SECTION 02612 NONREINFORCED CONCRETE SEWER PIPE
SECTION 02612 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Furnishing and installing nonreinforced concrete sewer pipe. Provide concrete sewer pipe less than 12 inches in diameter, and in other sizes
Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE
1.0 GENERAL 1.1 DESCRIPTION This section addresses the procedures to be employed for pipe bursting existing water/sewer pipelines, as identified on the drawings, and replacing with new Restrained Joint
DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES 33 00 00 SITE UTILITIES
SECTION INCLUDES Domestic Water Fire Water Service Water Well Sanitary Sewer Storm Drains Foundation Drainage RELATED SECTIONS 03 30 00 Concrete 21 00 00 Fire Suppression - Sprinklers 22 00 00 Plumbing
1.3.2 Method of construction and restoration of existing water service connections. This shall include:
1.0 GENERAL 1.1 DESCRIPTION: This specification shall cover the rehabilitation of existing water lines using the GRUNDOCRACK PIPE BURSTING SYSTEM. Pipe bursting is a system by which the pneumatic bursting
San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
For drinking water pipe distribution systems, both main and supply lines Sewer and discharge pipe systems
Technical Information UPVC upvc (unplasticized polyvinylchloride) pipes and fittings exhibit excellent resistance to aggressive environments both naturally occurring and as a result of industrial activity.
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION
SECTION 15125 HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION PART 1 GENERAL.01 SECTION INCLUDES Furnishing and installing 4 inch through 16 inch high density
Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development
7 SPECIFICATIONS There is currently no Irish specification for construction of drainage works, or water supply works. There are several publications that give guidance on drainage works, such as the Building
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY
STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY Approved and adopted as Official Document Number 800576 this 10th day of December, 1980 Donald R. Boyd, P.E., Director Water
SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE
6.01 SCOPE The work covered by this section of the specifications consists of the furnishing of all plant, labor, materials, equipment and supervision and performing all operations involved in the construction
Reticulation sewers in basements Technical guidelines
Reticulation sewers in basements Technical guidelines Overview What These guidelines explain our technical requirements for laying sewers in building basements. The scope of the guide is restricted to
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
LEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
The surface roughness of the polyurethane lining is 10 times lower than cement-lined pipes.
QUALITY INSIDE When it comes to long life piping for drinking water, sewage, industrial water or gas, there is one name that continues to lead the way - ECOPUR by vonroll. Delivering precision-engineered
Integrated Manhole Ladder System
Application: This innovative product has been designed to provide safe access and egress to precast concrete manholes and inspection chambers. It can also be used within any other underground concrete
Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD 21.01 SCOPE: It is the intent of the Specification to define the approved methods and materials
Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation by Tunnelling
Engineering and Construction Services Division Standard Specifications for Sewers and Watermains TS 415 April 2013 Amendment to OPSS 415 (Nov 2008) Construction Specification for Pipeline and Utility Installation
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
Flowtite Jacking Pipe
U.S. COMPOSITE PIPE SOUTH, LLC. MEMBER OF KTI PIPE GROUP OF COMPANIES Flowtite Jacking Pipe 18585 Samuels Rd. Zachary, La. 70791 PH. 225-658-6166 Fax 225-658-0947 www.flowtitepipe.com Flowtite GRP Pipe
LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION
LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION Le Val LUND 1 And P E M ASCE 2 SUMMARY A number of methods are discussed which can be used for lifeline pipeline rehabilitation and improving the seismic
I BEAM TRACK INSTALLATION
PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must
Embedded Parts Introduction - Anchors
In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical
Technical Information
Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast
SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.
SECTION LS 2530 SANITARY SEWERS PART 1 GENERAL 1.1 SUBMITTALS A. General: Submit the following in accordance with The General Conditions. 1. Product data for drainage piping specialties. 2. Shop drawings
General Guidelines for Repairing Buried PE Potable Water Pressure Pipes
515 General Guidelines for Repairing Buried PE Potable Water Pressure Pipes Introduction Traditional piping systems have gasket-sealed bell and spigot joints every 20 feet, which can be a potential maintenance
08003-1 WATER SERVICE 2
08003_Mar08_2011.pdf Page 1 of 7 INDEX Page 08003-1 WATER SERVICE 2 1.1 Pipe 2 1.1.1 Copper 2 1.1.2 Polyethylene 2 1.2 Valves and Fittings 2 1.2.1 Main Stops 3 1.2.2 Curb Stops 3 1.2.3 Curb Box 3 1.2.4
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)
Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal) IMPORTANT: It is imperative that the user read these warnings and use of the assembly instructions
[email protected] TRADE PRODUCT GUIDE MAKE THE RITE CONNECTION WWW.FABFIT.COM.AU www.fabfit.com.au Page a
Page a TRADE PRODUCT GUIDE MAKE THE RITE CONNECTION WWW.FABFIT.COM.AU Manufacturers and distributors of plumbing fittings. Fabfit Certification The following trade products guide details the range of plumbing
IS THAT LINER THICK ENOUGH?
IS THAT LINER THICK ENOUGH? Philip McFarlane, Opus International Consultants Ltd ABSTRACT The amount of pipeline rehabilitation being undertaken in New Zealand is increasing each year. Larger diameter
DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015
DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT Jim Riley, Texas A&M University February 10, 2015 Piping at Texas A&M 2 History of Distribution Piping at Texas A&M Concrete reinforced
Ridgistorm-XL - the latest innovative
Ridgistorm-XL - the latest innovative solution to SUDS and stormwater management Combined with the technical expertise, knowledge and support of Polypipe, Ridgistorm-XL is designed as a bespoke application
Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology
2007 Pumper & Cleaner Environmental Expo International Wednesday February 7, 2007 Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology What is Cured-In-Place Pipe (CIPP)
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com.
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. 2 0 0 5 D U K E A I R X C / S L / R A C E S E R V I C E G U I D E Information
THERMA-TUBE preinsulated pipes and fittings Catalogue of products
THERMA-TUBE preinsulated pipes and fittings Catalogue of products THERMA TUBE preinsulated pipes and fittings TABLE OF CONTENTS 1. GENERAL INFORMATION ABOUT THE USE OF PREINSULATED PIPES AND FITTINGS...
PART 5 : WASTEWATER DRAINAGE
Authorised by : City Waters Unit Manager Page 1 of 15 PART 5 : WASTEWATER DRAINAGE 5.1 INTRODUCTION This Manual sets out the basic design principles for drainage of wastewater. While some construction
4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.
User s Guide to: Phoenix Vessel Technology Limited 4-600, 1000 psi End port pressure vessels Model numbers: 1386, 1384. Phoenix Vessel Technology Limited Unit 2, The Old Bakery, Lower Tuffley Lane, Gloucester
PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE
Sl.No. PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE Description of item Qty Unit Rate Amount 1 Demolishing tile work/cement concrete/( carefully taking out the closet and other
Sewer Rehabilitation Design Requirements
Sanitary Sewer Overflow (SSO) Control and Wastewater Facilities Program Sewer Rehabilitation Design Requirements City of Baton Rouge/Parish of East Baton Rouge Department of Public Works Submitted by Prepared
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive
Connection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, 2012. Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?
Pipe Bursting Case Study at Zeeland, MI Collections Seminar September 6, 2012 By: Brian Hannon, PE and John Racek, PE Presentation Agenda What is Pipe Bursting? History of Pipe Bursting Types of Pipe Bursting
Shower and Floor Gullies Channel Drain and Tile Drain SECTION
Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions
SECTION 02732 BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.
SECTION 02732 BUILDING SEWERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Lateral piping, fittings, and accessories. B. Connection of building sanitary drainage system to municipal sewers. 1.02 REGULATORY
TECHNICAL SPECIFICATION
THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,
Grade Level Spill Containment Manholes
Grade Level Spill Containment Manholes Installation Instructions 705-5 Gallon 715-15 Gallon 725-25 Gallon Manual # Revision Date Changes from Previous Revision F-1307 7 Mar. 2012 Removed reference to pipe
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com.
For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at www.rockshox.com. Information contained in this publication is subject to change at anytime
SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS
TABLE OF CONTENTS 2.18 CONCRETE AND/OR CORRUGATED STEEL STORM SEWER... 1 2.18.1 GENERAL... 1 2.18.2 MATERIALS... 1 2.18.2.1 Storm Sewer Pipe... 1 2.18.2.2 Cement Mortar... 1 2.18.2.3 Granular Materials...
GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS
GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS 13.1 13.2 2006 Edition SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS GENERAL
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
PLANNING CAREFUL NORTH VANCOUVER PIPE BURST REQUIRES
WATER & SEWER REHAB TECHNOLOGIES NORTH VANCOUVER PIPE BURST REQUIRES CAREFUL PLANNING Close proximity to storage silos, poor ground conditions and clogged storm sewer pipe puts trenchless contractor to
725-R-599 PIPE LINING. (Revised 05-01-12) SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING PIPE
PIPE LINING (Revised 05-01-12) The Standard Specifications are revised as follows: SECTION 725, DELETE LINES 1 THRU 317. SECTION 725, BEGIN LINE 1, INSERT AS FOLLOWS: SECTION 725 SLIP LINING OF EXISTING
The Manitoba Water Services Board SECTION 022180 Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11
Page 1 of 11 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the excavation of trenches (or excavation of tunnels); the supply and placing of bedding and backfill materials;
SECTION 33 31 00.11 GRAVITY SANITARY SEWERS
SECTION 33 31 00.11 GRAVITY SANITARY SEWERS PART 1: GENERAL 1.01 SCOPE A. Gravity sanitary sewers and appurtenances. 1.02 SUBMITTALS A. Conform to requirements of Section 01 33 00 Submittals. B. Submit
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
System. Stability. Security. Integrity. 150 Helical Anchor
Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair
BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION
BEST PRACTICE GUIDELINES FOR CULVERT LINER SELECTION GENERAL Rehabilitation of culverts with pipe liners is one of several methods available for extending the life of an existing culvert. It is often cost
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
TRENCHLESS TECHNOLOGY RESOURCE CENTRE TRENCHLESS TECHNOLOGY GUIDELINES
TRENCHLESS TECHNOLOGY RESOURCE CENTRE TRENCHLESS TECHNOLOGY GUIDELINES SECOND EDITION PIPEJACKING AND MICROTUNNELING NEW VERSION AUGUST 2005 1 OVERVIEW Pipe jacking and microtunnelling, including pilot