How To Manage An Inventory On A Tivoli Netcool Performance Manager Datamart Datamart.Com (Sbt) On A Microsoft Powerbook (Powerbook) On An Ipa (Powerstation) Or Ipa 2 (Powergen

Size: px
Start display at page:

Download "How To Manage An Inventory On A Tivoli Netcool Performance Manager Datamart Datamart.Com (Sbt) On A Microsoft Powerbook (Powerbook) On An Ipa (Powerstation) Or Ipa 2 (Powergen"

Transcription

1 Tivoli Netcool Performance Manager Wireline Component Document Revision R2E1 IBM SNMP Inventory Management and Troubleshooting Guide

2 Contents Preface Audience Organization The Tivoli Netcool Performance Manager Product Suite Tivoli Netcool Performance Manager Documentation Chapter 1: Introduction Overview Discovery Metrics and Properties Inventory Synchronization and Change Management Change Management for Elements Change Management for Sub-Elements Grouping Sub-Elements Where to Go From Here Chapter 2: SNMP Inventory Troubleshooting Overview Discovery Troubleshooting Discovery Does Not Start Discovery Starts But Issues Warning Messages Discovery Seems to Hang or Never Finishes Synchronization Troubleshooting Synchronization (Elements) Synchronization (Sub-elements) Grouping Troubleshooting Monitoring the Tivoli Netcool Performance Manager Log File Burned Subelements Scenario 1 - Instance Shift Causes Disconnect Scenario 2 - Instance Shift Causes Burn Where to Go From Here Netcool/Proviso SNMP Inventory Management and Troubleshooting Guide, Version

3 Contents Chapter 3: SNMP Inventory Management Overview Routine SNMP Inventory Management Tasks Finding Elements and Sub-elements About to Reach Their Retry Limit Finding Elements and Sub-elements That Have Been Retired Where to Go From Here Netcool/Proviso SNMP Inventory Management and Troubleshooting Guide, Version 4.4.1

4 Preface The purpose of this guide is to help you manage and troubleshoot problems with the Tivoli Netcool Performance Manager SNMP Inventory. Audience The audience for this guide is the Tivoli Netcool Performance Manager administrator. Organization This guide is organized as follows: Chapter General information about the audience, guide, conventions, documentation, and technical support. Chapter 1, Introduction on page 1 Provides an overview of the Tivoli Netcool Performance Manager SNMP Inventory process. Chapter 2, SNMP Inventory Troubleshooting on page 5 Provides a list of troubleshooting tasks that the Tivoli Netcool Performance Manager Administrator might be called upon to perform during an SNMP Inventory. Chapter 3, SNMP Inventory Management on page 33 Provides a list of recurring management tasks that the Tivoli Netcool Performance Manager Administrator should perform on a regular basis. The Tivoli Netcool Performance Manager Product Suite Tivoli Netcool Performance Manager is made up of the following components: Tivoli Netcool Performance Manager DataMart is a set of management, configuration and troubleshooting GUIs that the Tivoli Netcool Performance Manager System Administrator uses to define policies and configuration, as well as verify and troubleshoot operations. Tivoli Netcool Performance Manager DataLoad provides flexible, distributed data collection and data import of SNMP and non-snmp data to a centralized database. Tivoli Netcool Performance Manager DataChannel aggregates the data collected through Tivoli Netcool Performance Manager DataLoad for use by the Tivoli Netcool Performance Manager DataView reporting functions. It also processes on-line calculations and detects real-time threshold violations. Tivoli Netcool Performance Manager DataView is a reliable application server for on-demand, webbased network reports. Tivoli Netcool Performance Manager Technology Packs extend the Tivoli Netcool Performance Manager system with service-ready reports for network operations, business development, and customer viewing. The following figure shows the different Tivoli Netcool Performance Manager modules. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

5 Preface Figure 1: Tivoli Netcool Performance Manager Modules DataLoad collects network data. DataChannel computes aggregations and stores data in DataMart. DataMart provides data management and applications. DataView produces and manages reports. Tivoli Netcool Performance Manager Documentation Tivoli Netcool Performance Manager documentation consists of the following: release notes configuration recommendations user guides technical notes online help The documentation is available for viewing and downloading on the infocenter at: 5 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

6 Chapter 1: Introduction This chapter provides an introduction to the Tivoli Netcool Performance Manager SNMP Inventory, and is made up of the following topics: Topic Page Overview 1 Discovery 2 Inventory Synchronization and Change Management 2 Grouping Sub-Elements 4 Where to Go From Here 4 Overview Tivoli Netcool Performance Manager allows the operator to decide how much the Tivoli Netcool Performance Manager DataMart will rely upon the OSS Inventory system. The Inventory system can be virtually anything from a full-featured commercial Inventory package, to an EMS or Node Manager like HP Open View, to a flat file like /etc/hosts. The minimum required is a list of the IP addresses of resources to monitor. Tivoli Netcool Performance Manager can discover both elements (resources that have an IP address, such as a router or a switch), and the sub-elements associated or contained with them, such as an interface or a port. Tivoli Netcool Performance Manager supports the following three modes of element and sub-element discovery: Mode Inventory Contains Tivoli Netcool Performance Manager Discovers 1 Nothing Elements, sub-elements 2 Elements Sub-elements 3 Elements, Sub-Elements Nothing Most Tivoli Netcool Performance Manager deployments are in mode two. In this mode, Tivoli Netcool Performance Manager imports a list of elements and then walks through the MIB to discover the sub-elements. In the first mode, Tivoli Netcool Performance Manager sweeps the network to discover the elements and their associated sub-elements. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

7 Chapter 1: Introduction Discovery Tivoli Netcool Performance Manager s Discovery capabilities include some powerful and flexible tools that allow you to determine exactly what Tivoli Netcool Performance Manager will monitor, and how the sub-elements will be labeled and grouped. These capabilities make it possible to initiate automatically data collection, threshold monitoring, and reporting on discovered elements. Using a formula language, Tivoli Netcool Performance Manager can be configured to walk through an element s MIBs to discover particular MIBs representing users, tunnels, protocols, service classes or other sub-elements. Particular OIDs can be used to automatically create a label for the sub-element. For example, the sub-element label could be a combination of the element name, the interface, the port and the customer name, all taken from the MIB. Metrics and Properties In addition to the identifier of the sub-element and the metrics collected for it, Tivoli Netcool Performance Manager allows the operator to create any number of user-defined properties. There are two main differences between metrics and properties. Metrics come from a monitored resource and are used to calculate statistics that are the basis of performance reports and alarm thresholds. Metrics are generally numeric values that change frequently, like the number of packets transmitted or a resource s availability. Properties, by contrast, are values that change less frequently, such as the CIR (committed information rate) or the location of the element. Properties consist of metadata-like identifiers or labels for such things as the customer and/or the services using a particular sub-element. The values for properties can be discovered automatically from the monitored resource, or they can be imported from Inventory, provisioning or from another OSS component. Inventory Synchronization and Change Management Sub-element properties such as the CIR or customer name can change. Tivoli Netcool Performance Manager tracks the change and the time of the change, so that reports are displayed correctly. For example, utilization may be calculated against CIR. After the CIR is updated, reports must reflect the new value for utilization calculations. But reports that show dates prior to the CIR update must use the old CIR value. Tivoli Netcool Performance Manager manages this without error. If a sub-element is assigned to a new customer, the customer property will change. If the sub-element is in a particular customer s group, this can cause the sub-element to move to a new group. This can change the collection, alarm thresholds and reporting for that sub-element, automatically. Change Management for Elements Unfortunately, Inventory is not as simple as sweeping a range of IP addresses to identify the network elements. That is just the beginning of the process. The Inventory must track changes so that continuity of meta-data associated with the elements (such as associations to customers, VPNs and services) can be maintained. At least one additional challenge remains to keep the element Inventory accurate, as shown with these two problem statements: IP Address changes 2 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

8 Chapter 1: Introduction Problem: If you are tracking a router by its IP address, and you discover a router at a new IP address, how do you know if it is a new router, or an existing router with a changed IP address? Tivoli Netcool Performance Manager solves this problem by associating additional properties with each element which provide additional continuity and trace-ability in the face of IP address changes. These additional properties can be discovered from the device itself, like SNMP sysname, or gathered externally, like the name resolved from the IP address of the element s management interface. Name changes Problem: If you are tracking a router by its name, and you discover that the name has changed, how do you know if it is a new router with that IP address, or an existing router with a changed name? Tivoli Netcool Performance Manager does not track elements by their name or any other single property. Instead, by tracking a combination of properties, Tivoli Netcool Performance Manager is able to provide continuity to inventory even when any of these properties change. By automatically tracking changes to an element, rather than discovering it as a new element or forcing the operator to manually update the database, Tivoli Netcool Performance Manager helps reduce operating costs as follows: Performance and trend reports for the element show the entire history of the element, without interruption. Changes to the element are shown in historical reports so they can be correlated to problems or changes in performance. Meta-data, such as location, community string, or other properties remains associated with the element, saving the operator from having to re-enter this. Inventory accuracy is improved because the update operation is automatic, not manual, eliminating errors. Inventory accuracy is improved because synchronization is automated, eliminating manual delays. Change Management for Sub-Elements In addition to the challenge of detecting and correctly managing changes on sub-elements, it is important to display this information correctly on reports. From an external (customer) point of view, subelement changes should be invisible. From an internal (network operations) perspective, the change must be visible. Tivoli Netcool Performance Manager manages all of this automatically. There are many reasons why the identifier (in SNMP, the Object Identifier, or OID) might change for a particular sub-element. Assuming that the sub-element is a port or virtual circuit residing on an interface, some of the changes will be due to failure and recovery scenarios, or network reconfigurations due to growth: Adding or removing an interface card can cause the SNMP indexes to shift for other sub-elements. The interface the sub-element resides upon might fail, forcing the service associated with the sub-element to be moved to another interface. The service may be moved to a currently unused sub-element.the service may be moved to a sub-element in use, and the service currently on the sub-element is moved to another sub-element Most network changes should be invisible to customers. Their reports should reflect the quality of their service, and moves and changes to the network to preserve their service should be invisible to them. This is particularly important for SLA reporting. You certainly want to avoid forcing the customer to view two reports, one for the original NIC and a second report for the replacement NIC. Throughout the network changes, network operations and engineering staff must have an accurate view of the actual sub-elements. For troubleshooting and capacity planning purposes, they should have a historical view of performance and traffic on a particular port, with information on changes that have occurred. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

9 Chapter 1: Introduction Grouping Sub-Elements Properties can be used to automatically group sub-elements. For example, sub-elements can be grouped according to technology, customer, service or site. Groups can be hierarchical, so it is possible to create structures like the following: Site/Technology, to see all ATM SVCs in the New York POP. Customer/Service, to show all of the services a particular customer has subscribed to. Technology/Site, to see which sites are generating the most Frame Relay activity. Sub-elements can exist in multiple groups simultaneously. For example, a sub-element might be part of a network operations group and a particular customer s group. Where to Go From Here For information on troubleshooting tasks to perform after a new SNMP Inventory has been run, see Chapter 2, SNMP Inventory Troubleshooting on page 5. For information on periodic administrative tasks to perform, see Chapter 3, SNMP Inventory Management on page Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

10 This chapter discusses SNMP Inventory troubleshooting, and is made up of the following topics: Topic Page Overview 5 Discovery Troubleshooting 7 Synchronization Troubleshooting 21 Grouping Troubleshooting 28 Monitoring the Tivoli Netcool Performance Manager Log File 29 Where to Go From Here 32 Overview The Tivoli Netcool Performance Manager SNMP Inventory consists of the following three major phases, which usually happen sequentially: SNMP Discovery Detects all resources on a target network and creates a virtual image of the network. Synchronization Compares the virtual network image generated by the Discovery with the records in the Tivoli Netcool Performance Manager database that were created by the previous Inventory run. Any modifications (new, missing, or renamed resources, for example) are then synchronized through the application of various algorithms, and the new network image is written to the database. Grouping Updates the grouping structure in the database, which determines the kind of information that is to be collected on each resource, element, sub-element, and so forth. In almost all cases, Tivoli Netcool Performance Manager s SNMP Inventory requires virtually no operator intervention. However, under certain circumstances, problems arise which you will need to address. The following sections discuss the more common problems you are likely to encounter and where possible provide suggestions for remedial actions. We strongly suggest that you monitor the logs for potential error messages by doing one of the following: Running a Discovery from the command line. If you run a Discovery from the command line, redirect STDER to a log file, as follows: inventory -nox -action discovery -name lowell >output 2>error_log Note: For a complete list of error messages written to the Tivoli Netcool Performance Manager log file, see the Tivoli Netcool Performance Manager Error Messages Guide. For more information on using the Tivoli Netcool Performance Manager log file, see Monitoring the Tivoli Netcool Performance Manager Log File on page 29. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

11 Running a Discovery from the DataMart GUI If you use the DataMart GUI to initiate a Discovery, error messages will appear on the DataMart GUI- >Resource tab->inventory Tool icon -> Live Information tab, as shown in Figure 2:. Figure 2: Errors Displayed in the DataMart GUI General profile settings. Discovery run ID Command to extract all messages of a specified IP address from: $PVMHOME/log/TraceInventory.log Discovery progress The Inventory Tool prints out messages like the following every five seconds: 2005/12/09 13:46:52 [PL2DBS1, 238 sec, IP done.1/ SNMP done.1/ Elmt 0.1.0/ SubElmt 0.0.0] These messages explain the progress of the discovery as follows: IP done.1 Indicates that the IP phase of the discovery process has completed. SNMP done.1 Indicates that the SNMP phase of the discovery process has completed. Elmt Indicates that progress of discovered elements, using the following syntax: numberofobjectsininputqueue.numberofthreadsrunning.numberofelementsdiscovered SubElmt Indicates that progress of discovered sub-elements, using the following syntax: numberofobjectsininputqueue.numberofthreadsrunning.numberofsubelementsdiscovered If after two minutes there is no change in these messages, the Inventory Tool displays a more detailed message like the following: 2005/12/09 13:46:57 Current /12/09 13:46:57 Stage: IP done /12/09 13:46:57 Stage: SNMP done /12/09 13:46:57 Stage: Elmt /12/09 13:46:57 W: R00004/ /12/09 13:46:57 Stage: SubElmt The line that includes the run number and IP address (2005/12/09 13:46:57 W: R00004/ , for example) can be used to troubleshoot possible problems, as explained in Discovery Seems to Hang or Never Finishes on page Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

12 Discovery Troubleshooting The following sections address the more common problems that arise during Discovery. Discovery Does Not Start The following sections offer the most common solutions to problems with Discovery not starting. Discovery Fails Because Discovery Server Does Not Run If the Discovery server fails to start, an error message like the following is returned: IIOP: couldn't connect to :34024: couldn't open socket: connection refused Error: StartInventory Failed for Discovery Server : IDL:omg.org/CORBA/INTF_REPOS:1.0 {minor 0 completion_status COMPLETED_NO} To troubleshoot this problem, do the following: 1. Log in as pvuser on the system where the channel manager and log server are installed. 2. Change your working directory to the $DC_HOME/bin directory, by entering the following command. Note that $DC_HOME is defined as /opt/datachannel by default. cd $DC_HOME/bin 3. Verify that the Discovery server is not running by entering the following command: $ dccmd -action status -pattern DISC.*.* If the Discovery server is not running, the dccmd command returns output like the following: NUMBER FACILITY HOST STATUS ES DURATION EXTENDED STATUS 1 DISC unresponsive ACTION: If the Discovery server is not running, do the following: 1. Restart the Discovery server by entering a command like the following, specifying the Discovery server for your deployment (in this example we use DISC.DEV19.1): dccmd action bounce pattern DISC.DEV Verify that the Discovery server is running by entering the following command: dccmd -action status -pattern DISC.*.* If the Discovery server is running, the dccmd command returns output like the following: NUMBER FACILITY HOST STATUS ES DURATION EXTENDED STATUS 1 DISC DEV19.QUALLA running 1 running For more information on using the dccmd command, see the Netcool/Proviso Command Line Interface Guide. Discovery Fails Because Collector Stops During Discovery If the collector stops during a Discovery, several different error messages are logged. The most common error messages are the following: Error: Aborted at March 14, :21:58 pm Error: Connection refused Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

13 . Chapter 2: SNMP Inventory Troubleshooting Error: Discovery Server : Status of lowell : invalid CLIENTERR [DC1] R00015 Connection refused (-I 682 -D 0 -profil lowell -collector dev19.quallaby.com:3002 -nbgetifaddress 100 -invfiletxt /opt/datamart/conf/inventory_subelements.txt -vname {} -intcollector 1) To troubleshoot this problem, do the following: 1. Log in as pvuser (or the user name that you specified during installation) on the system where DataMart is installed. 2. (Optional) Ensure that the Oracle database and Listener are running. For more information, see the Tivoli Netcool Performance Manager Installation Guide. 3. Enter the following command, replacing DATAMART_ROOT with the root DataMart directory (/opt/datamart by default): DATAMART_ROOT/bin/pvm The DataMart GUI appears, as shown in Figure 3:. Figure 3: DataMart GUI Name of the system where Tivoli Netcool Performance Name of the system where the database is installed. 4. Click on the Collector Information icon. The Collector Information Tool appears, as shown in Figure 4:. 8 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

14 . Chapter 2: SNMP Inventory Troubleshooting Figure 4: Collector Information Tool The Collectors Tab lists all the collectors loaded from the database. 5. Select the collector that you are troubleshooting. You look for the collector name in the output of the Live Information tab of the Discovery trace, as follows (in this example, the collector is dev19.quallaby.com): BeforeDiscovery for lowell : nothing to do Running Discovery on profile : lowell (mode 1) Enforce SE invariant uniqueness per element : active (from profile ) Duplicate IpAddress: active with collector number: 1 (dev19.quallaby.com:3002) (from profile ) Sub-element configuration file: /opt/datamart/conf/inventory_subelements.txt (from profile ) Discovery collector number: 1 (dev19.quallaby.com:3002) (from profile ) Start Reload formulas on dev19.quallaby.com: Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

15 Figure 5: Stopped Collector ACTION: Restart the collector by entering the following command on the Collector server: /opt/dataload/bin/pvmdmgr start Note: The collector cannot be restarted from the GUI. Discovery Does Not Start Because Inventory is Locked To troubleshoot this problem, do the following: 1. Log in as pvuser (or the user name that you specified during installation) on the system where DataMart is installed. 2. (Optional) Ensure that the Oracle database and Listener are running. For more information, see the Tivoli Netcool Performance Manager Installation Guide. 3. Enter the following command, replacing DATAMART_ROOT with the root DataMart directory (/opt/datamart by default): DATAMART_ROOT/bin/pvm The DataMart GUI appears, as shown in Figure 3:. 4. Click on the Resource tab->inventory Tool icon. The Inventory Tool appears, as shown in Figure 6:. Figure 6: Inventory Tool 5. Click on the Live Information tab. If the profile is locked, you will see a warning message like the one displayed in Figure 6:. 6. To confirm that the profile is locked, return to the DataMart GUI and click on the Monitor tab->datamart Status icon. The DataMart Status Tool appears, as shown in Figure 7:. 10 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

16 Figure 7: DataMart Status Tool In this example, the Inventory profile lowell is locked by an Inventory process with a PID of Determine if the lock is valid and if the process is still running, by entering the following command, replacing LOCK_PROCESS_PID with the PID of the locking process (13458 in our example): ps -aef grep LOCK_PROCESS_PID ACTION: If the process is active, the lock is valid and you should wait until the Inventory completes before running another Inventory. ACTION: If the process is inactive, remove the lock and start another Inventory. To remove the lock, click on the Remove Locks icon located in the upper left of the toolbar. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

17 The qping Utility Has Incorrect Settings As part of Discovery in Inventory Mode 1, Tivoli Netcool Performance Manager scans IP ranges using the DataLoad qping utility. This utility will fail with the following error messages if group, user, and execute permissions are not set correctly on the file: To troubleshoot this problem, do the following: 1. Log in as pvuser (or the user name that you specified during installation) on the system where the DataLoad server is installed. 2. Change your working directory to $PVMHOME/bin (/opt/dataload/bin by default), and enter the following command to check the settings on the qping utility: cd $PVMHOME/bin ls -l./qping The correct settings are as follows: -r-sr-sr-- 1 root pvusers Jan 14 15:31 /opt/dataload/bin/qping ACTION: If the settings are not correct, su to root and enter the following commands: chown root $PVMHOME/bin/qPing chmod 6554 $PVMHOME/bin/qPing chgrp pvusers $PVMHOME/bin/qPing Verify the settings by entering the ls -l command again. Important: The qping utility and the DataLoad user must belong to the same group (in our example, pvusers). The sticky bit setting ( s in the ls -l line) allows the utility to be executed as root by any UNIX user belonging to the pvusers group. 12 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

18 Discovery Starts But Issues Warning Messages The following sections offer the most common solutions to warning messages that occur during Discovery. IP Addresses Are Rejected If an IP address is rejected during Discovery, errors like the following will be written to the log or will display on the Information Tab of the Inventory Tool: Warning: IP Address rejected because this IP address has been excluded. Warning: IP Address rejected because this IP address has been excluded. Important: In most cases, this is not a problem. To troubleshoot this error message, do the following: 1. Log in as pvuser (or the user name that you specified during installation) on the system where DataMart is installed. 2. (Optional) Ensure that the Oracle database and Listener are running. For more information, see the Tivoli Netcool Performance Manager Installation Guide. 3. Enter the following command, replacing DATAMART_ROOT with the root DataMart directory (/opt/datamart by default): DATAMART_ROOT/bin/pvm The DataMart GUI appears, as shown in Figure 3:. 4. Invoke the Discovery Tool Wizard by doing the following: 4-a. Select the Resource Tab->Inventory Tool icon. The Inventory Tool appears with the Configuration Tab displayed, as shown in Figure 8: Figure 8: Inventory Tool Configuration Tab 4-b. Highlight a profile and then select Edit->Profile or click on the edit icon Wizard appears, as shown in Figure 9.. The Inventory Tool Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

19 Figure 9: Inventory Tool Wizard 4-c. Click the Next button twice to navigate to the Discovery Tool Wizard, as shown in Figure 10:. Figure 10: Discovery Tool Wizard ACTION: As shown in Figure 10:, check to see if the rejected IP addresses either individually or within a specified range have been intentionally excluded. If they have not, contact Micromuse support. Duplicate Elements Are Found If the same element, a router for example, has more than one IP address associated with it, Tivoli Netcool Performance Manager will discover the element multiple times, reject the duplicates discoveries, and write warning messages to the log. Figure 11:, for example, shows Tivoli Netcool Performance Manager rejecting three duplicate elements. 14 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

20 Figure 11: Rejected Duplicate Elements This is expected behavior. ACTION: If these warning messages appear often, Discovery performance may be degraded, since Tivoli Netcool Performance Manager must spend a lot of time calculating and eliminating duplicate elements. You may therefore want to exclude the duplicate addresses from the Discovery by doing the following: 1. Invoke the Discovery Tool Wizard (DTW). For instructions on how to invoke the DTW, see STEP 4 on page 4. on Add the duplicated IP addresses to the IP address exclude area of the DTW, as shown in the following figure: Elements Are Not Identified During Discovery If DataLoad did not receive an SNMP answer using the community name configured in the Tivoli Netcool Performance Manager profile, warning messages like the following are written to the log and displayed on the Live Information Tab of the Inventory Tool: Warning: Unidentified Agents= { , , , , , , , , , } Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

21 Warning: Unidentified Agents= { , , , , , , , , , } Devices may fail to respond for reasons like the following: The device is not reachable from DataLoad collector (for example, no network route). The SNMP agent was not started in the device. Tivoli Netcool Performance Manager has the wrong SNMP community name for the device. The device Access List is preventing Tivoli Netcool Performance Manager DataLoad to act as an SNMP Manager for this device. The firewall configuration is preventing SNMP traffic with the device. To troubleshoot this problem, follow these steps: 1. Log in as pvuser (or the user name that you specified during installation) on the system where DataMart is installed. 2. (Optional) Ensure that the Oracle database and Listener are running. For more information, see the Tivoli Netcool Performance Manager Installation Guide. 3. Change your working directory to DATAMART_ROOT/bin, replacing DATAMART_ROOT with the root DataMart directory (/opt/datamart by default). 4. Perform an Internet Control Message Protocol (ICMP) query on the device, by entering the following command, replacing IP_ADDRESS_OF_UNIDENTIFIED_DEVICE with the IP address of the unidentified device, and NAME_OF_COLLECTOR_SERVER_DOING_PING with the name of the collector server doing the ping: qping IP_ADDRESS_OF_UNIDENTIFIED_DEVICE -S NAME_OF_COLLECTOR_SERVER_DOING_PING If successful, the qping command returns the IP address of the unidentified device, as follows: $ qping S dev :10 5. Connect to the device and verify whether or not the SNMP agent is enabled and running. 6. Connect to the device and verify the community name. 7. (Optional) You might have to change the community name in Tivoli Netcool Performance Manager, by using the DataMart->Inventory->Discovery Wizard to add an "alternate" community name to the profile. To change the community name, follow these steps: 7-a. Invoke the Discovery Tool Wizard (DTW). For instructions on how to invoke the DTW, see STEP 4 on page 4. on b. Add an alternate community name in the specified text box. 7-c. Click the Add button to confirm your choice, as shown in the following figure: 16 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

22 Elements Skipped Because No Related Sub-Elements When Tivoli Netcool Performance Manager discovers an element but cannot discover any related sub-elements, warning messages like the following are written to the log and displayed on the Information Tab of the Inventory Tool: Skipping 3 elements (Set (' _jeffs2' ' _default' ' _jeffs1')) in output file, because they don't have related subelements Important: This is not expected behavior, and should be resolved immediately. To troubleshoot this problem, follow these steps: 1. Log in as pvuser (or the user name that you specified during installation) on the system where DataChannel is installed. 2. Change your working directory to $DC_HOME/log (/opt/datachannel/log by default), by entering the following command: cd $DC_HOME/log 3. Enter the following command to search the proviso.log for the Discovery formula of the skipped element, replacing EL_IP_AD, with the IP address of the skipped element: grep DISC proviso.log grep R00020 grep ELS_IP_AD grep CHKDISCOVERY The grep command returns no output. ACTION: If the grep command does not return output, the content of the following files in the $PVMHOME/conf directory ($PVMHOME is defined as /opt/datamart by default): $PVMHOME/conf/inventory_elements.txt $PVMHOME/conf/inventory_sub_elements.txt Contact Micromuse support. The grep command returns output like the following: UTC DISC.DEV CHKDISCOVERY R00020/ Family:Generic~Agent, try discoveryformula Formula (Basic_Element string) Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

23 UTC DISC.DEV CHKDISCOVERY R00020/ Family:1213_Device, try discoveryformula Formula (1213_Device ) UTC DISC.DEV CHKDISCOVERY R00020/ Family:IETF_IF, try discoveryformula Formula (IETF_IF ) ACTION: The following may be attempted: If you believe that the device should in fact respond, try to discover the device manually and monitor the trace, using the DataMart->Metric->Formula Editor, as shown in the following figure: Activate the relevant portion of the device MIB (for example SAA in the Cisco router). In some cases, SNMP attributes do not respond properly, and the Discovery formula for those devices must be changed. In this event, contact Micromuse support. Discovery Seems to Hang or Never Finishes If the Discovery server shows no progress for several minutes (up to thirty minutes in some cases), as shown in the following trace log, it has probably encountered problems with a Discovery formula: Problems real or apparent with Discovery formulas can be the result of the following: The SNMP agent is slow to respond. The network latency is very long. The Discovery formula is not well-suited to the SNMP agent. 18 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

24 Collector performance issues. When Tivoli Netcool Performance Manager is in such a state one of two things result: The Discovery formula finally succeeds and the Inventory continues. The Discovery hangs until the Inventory timeout occurs (two hours) when the following error message is written to the log file: Error: Profile is not progressing during the last 7201 seconds, aborting Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

25 ACTION: Contact Micromuse support. and provide them with the DATACHANNEL_ROOT/datachannel/log/[yyyy.mm.dd]SNMP.log Before contacting Micromuse support, and before the Discovery finishes or times out, do the following: 1. Determine which Discovery formula is causing the problem by doing the following: 1-a. 1-b. 1-c. Log in as pvuser (or the user name that you specified during installation) on the system where DataChannel is installed. Change your working directory to DATACHANNEL_ROOT/log, replacing DATACHANNEL_ROOT with the root DataMart directory (/opt/datachannel by default). Enter the following command to search the proviso.log for the Discovery formula: grep DISC proviso.log grep R00010 tail UTC DISC.PVDEMO CHKDISCOVERY R00010/ Family:Cisco_CBQoS_Action, try discoveryformula Formula (Cisco_CBQoS_Action ) In this example, the Discovery formula is Cisco_CBQoS_Action. 2. Determine the internal request ID that is stuck by doing the following: 2-a. Log in as pvuser (or the user name that you specified during installation) on the system where the DataMart or DataLoad server is installed. 2-b. Change your working directory to DATAMART_ROOT/log, replacing DATAMART_ROOT with the root DataMart directory (/opt/datamart by default). 2-c. Enter the following command to find the internal request ID, replacing SERVER_NAME with the name of the Tivoli Netcool Performance Manager DataMart server: statget -S SERVER_NAME grep -i once + [33] ID 96627,{CAL none (ONCE)(next=2005/03/15 20:32:16)}(P3) ACTIVE (LastExec): ServiceForm:(Trgt=(string) )(Form=(form)Cisco_CBQoS_Action) (Inst=)(RComm=public) + [40] ID 96683,{CAL none (ONCE)(next=2005/03/15 20:48:19)}(P1) ACTIVE (LastExec): ServiceSTAT (LONG) In this example, the internal request ID is Important: If the command returns no output, contact Micromuse support. 3. Enable limited debugging on the collector server in order to populate the log with additional information by doing the following: 3-a. Change your working directory to /opt/dataload/contribs. 3-b. Enter the following command, replacing TASKID with the Internal request ID you found in STEP 2 on page 2. on 20. dialogtest2 Debug 6.TASKID Tivoli Netcool Performance Manager outputs a message like the following: Set debug level to 6 for taskid Debug configuration: > Global Level= 1; Mask=FW > ID Level= 6; Mask=FWI1234 WARNING: DO NOT USE THE GLOBAL COLLECTOR DEBUGGER. 20 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

26 Synchronization Troubleshooting The following sections address the more common problems that arise during Synchronization. Synchronization (Elements) During the synchronization phase, Tivoli Netcool Performance Manager compares the virtual network image generated by the Discovery with the records in the Tivoli Netcool Performance Manager database that were created by the previous Inventory run. Any modifications (new, missing, or renamed resources, for example) are then synchronized through the application of various algorithms, and the new network image is written to the database. In order to track elements and sub-elements through subsequent inventories, Tivoli Netcool Performance Manager identifies them with a unique, never-changing identifier, called an invariant. The default element invariant, for example, is a concatenation of the following three attributes: The MIB II sysname The first IP address responding to the ICMP scan (in Inventory mode 1) or the one given in the the mode 2 Inventory file The fist valid physaddress (MAC address) in the MIB II iftable Table 1 illustrates the logic used to determine if a newly-discovered element is actually new or is an existing element that has moved or changed. Table 1: Synchronization Invariant Logic Element Attributes in Database MIB II sysname IP Address physaddress New Element If... Defined Defined Defined Two or three attributes have changed. Empty Defined Defined Two attributes have changed. Empty Empty Empty The resolved name is different from resolved name in the database. Note: If an element does not respond to one of these three MIB II attributes, contact Micromuse support. Important: To avoid synchronization errors, we strongly recommend that you limit device configuration changes to one attribute between two runs of an Inventory (Discovery and Synchronization). Pre-synchronization Summary As Tivoli Netcool Performance Manager prepares for synchronization, it compiles a list of the following types of elements: New Updated Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

27 Burned Unchanged Not Found Histo Reject Figure 12 shows the display written to the DataMart->Inventory Tool->Live Information tab, with this summary information highlighted: Figure 12: Pre-synchronization Summary The following sections discuss this summary in more detail. Identifying Not Found Elements ACTION: If the Pre-Synchronization summary lists any not found elements (there are three in Figure 12, for example), contact Micromuse support. Identifying Burned Elements In cases where the MIB II sysname, IP address, and physaddress are all defined for an element (the first row in Table 1), Tivoli Netcool Performance Manager may encounter a special situation if the MIB II sysname and phyaddress have changed, but the IP address remains unchanged. 22 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

28 In this special case, Tivoli Netcool Performance Manager creates a new element and writes it to the database. However, since the IP address for both elements is the same, so too is the resolved name, which means that the elements would be seen by Tivoli Netcool Performance Manager as the same element. To prevent this situation, Tivoli Netcool Performance Manager renames the initial elment with a Burned prefix, as shown in Figure 13:: Figure 13: Burned Element When Synchronization completes, a list of burned elements is written to the following file: PROFILE_HOME/PROFILE_NAME/synchro/e_burned.dat ACTION: If you have an e_burned.dat file, contact Micromuse support. The burned elements and their sub-elements are duplicated, and the statistics attached to these resources are not continuous in reports. Preventing Burned Elements Tivoli Netcool Performance Manager relies quite heavily on the sysname when calculating invariants. To prevent burned elements, so the following: 1. Do NOT change the sysname on a device when the lowest physaddress has also changed. 2. Ensure that the sysname is defined and not left empty. 3. Ensure that the sysname is defined with a unique value. 4. Minimize any changes to the sysname once they have been set, unless you want Tivoli Netcool Performance Manager to see the device as new and interrupt the continuity of statistics. Detecting Too Many New Elements If there has been extensive configuration changes before an Inventory run (for example, if two attributes were changed simultaneously on a router), Tivoli Netcool Performance Manager will discover and create a new element in the database. The consequences are severe: The element and its sub-elements are duplicated. The statistics attached to these resources are not continuous in the reports. Double polling might happen on "both", until the "first" device is "retired" by the Inventory. Aside from limiting device configuration changes to one attribute between two runs of an Inventory, there is no way to prevent this situation from occurring. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

29 When Synchronization completes, a list of new elements is written to the following file. Note that $PVMHOME is defined as /opt/datamart, by default: $PVMHOME/importexport/PROFILE_NAME/synchro/new_e.dat ACTION: If you have a new_e.dat file, check to ensure that the number of new elements is not unexpected. If the number is unexpected, contact Micromuse support. Note: A large new_e.dat file is to be expected the first time a network is discovered. Detecting Different Elements Resolved With the Same Name If the name resolution system (for example, DNS) assigns identical names to the IP addresses of different devices a configuration mistake Tivoli Netcool Performance Manager will produce the following error during Synchronization: Warning: IP Address rejected Warning: IP Address rejected When Synchronization completes, a list of rejected elements is written to the following file: PROFILE_HOME_DIRECTORY/PROFILE_NAME/synchro/duplicateElement_e.reject ACTION: If you have a duplicateelement_e.reject file, do the following: From the DataMart server, resolve the name of both conflicting IP addresses, in order to confirm the identical naming resolution. Fix the naming resolution system and start the same Inventory again. Do Not Delete Incorrectly Named Elements That Define SNMP Community Names When initially configuring Tivoli Netcool Performance Manager, you use the SNMP Configuration Tool, as shown in Figure 14:, to associate elements with their SNMP Community name so that Tivoli Netcool Performance Manager can read from the devices. Figure 14: Configuring SNMP Community Names The SNMP Configuration Tool writes this information to the database. 24 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

30 During the next Inventory run, the synchronization process sees the elements that were newly entered into the database by the SNMP Configuration Tool as missing all three invariant attributes (see row three in Table 1 on page 21). Tivoli Netcool Performance Manager then attempts to determine if a new element needs to be created by comparing the resolved names of the devices, with the following results: If the name that was entered into the SNMP Configuration Tool was the correct resolved name of the device, Tivoli Netcool Performance Manager will not create a new element and will instead update the attributes for the existing element with the discovered values. If the name that was entered into the SNMP Configuration Tool was the incorrect resolved name of the device, Tivoli Netcool Performance Manager will create a new element. On subsequent Discoveries, Tivoli Netcool Performance Manager will rediscover and eventually update this element and ignore the element with the incorrect resolved name. ACTION: Do NOT remove the element with the wrong resolved name from the database. Tivoli Netcool Performance Manager continues to use that entry for SNMP Community name mapping. If the entry is removed, Tivoli Netcool Performance Manager will lose the SNMP Community mapping and will not be able to read from that resource. Failed Synchronization While monitoring the Synchronization process, pay particular attention to failed elements, as shown in Figure 15:. Figure 15: Failed Elements and the Inventory Tool ACTION: If Synchronization reports failed elements (greater than 0), contact Micromuse support immediately. Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version

31 Synchronization (Sub-elements) The sub-element invariant is defined in the Discovery Formulas referenced in the file $PVMHOME/conf/inventory_sub_elements.txt. Note that $PVMHOME is defined as /opt/datamart by default. This invariant is usually defined differently per object type (for example, an SAA probe) and vendor (Cisco, for example). The logic used to decide if a newly-discovered sub-element is in fact new, depends on the following: If the invariant is not defined, the sub-element name (usually the concatenation of the element name and the SNMP instance) is used to determine if a new sub-element should be created or an existing one should be updated. Note: Any change to the name between two subsequent Discovery runs triggers the creation of a new sub-element. Important: An SNMP index (instance) change will trigger the creation of a new sub-element (because the SNMP index is part of the name), which will cause reporting discontinuity. If an invariant is defined, the parameter Enforce Sub-Element Invariant uniqueness per element" is used, which is set in the DataMart->Inventory->Discovery Wizard, as shown in the following figure: Note: If the option highlighted in the figure is checked, uniqueness is verified on a per element basis; if left unchecked, uniqueness is verified across the entire profile. Identical Sub-element Invariant If an invariant is defined for a particular type of sub-element (for example, Cisco SAA), Tivoli Netcool Performance Manager will check the uniqeness of that invariant during an SNMP Inventory. If Tivoli Netcool Performance Manager detects two sub-elements with the same invariant, it displays an error message like the following: Warning: Identical invariant detected for invariant _CBQoS class-default-match any -output-1 ( ,CBQoS<1107><1123> and ,CBQoS<1107><1177>). Important: When identical invariants are detected, neither sub-element is stored in the database. 26 Tivoli Netcool Performance Manager SNMP Inventory Management and Troubleshooting Guide, Version 1.3.1

IBM. Tivoli. Netcool Performance Manager. Cisco Class-Based QoS 2.2.0.0 Technology Pack. User Guide. Document Revision R2E1

IBM. Tivoli. Netcool Performance Manager. Cisco Class-Based QoS 2.2.0.0 Technology Pack. User Guide. Document Revision R2E1 Tivoli Netcool Performance Manager Document Revision R2E1 IBM Cisco Class-Based QoS 2.2.0.0 Technology Pack User Guide Note Before using this information and the product it supports, read the information

More information

IBM Tivoli Netcool Performance Manager Wireline Component January 2012 Document Revision R2E1. Pack Upgrade Guide

IBM Tivoli Netcool Performance Manager Wireline Component January 2012 Document Revision R2E1. Pack Upgrade Guide IBM Tioli Netcool Performance Manager Wireline Component January 2012 Document Reision R2E1 Pack Upgrade Guide Note Before using this information and the product it supports, read the information in Notices

More information

NNMi120 Network Node Manager i Software 9.x Essentials

NNMi120 Network Node Manager i Software 9.x Essentials NNMi120 Network Node Manager i Software 9.x Essentials Instructor-Led Training For versions 9.0 9.2 OVERVIEW This course is designed for those Network and/or System administrators tasked with the installation,

More information

WHITE PAPER September 2012. CA Nimsoft For Network Monitoring

WHITE PAPER September 2012. CA Nimsoft For Network Monitoring WHITE PAPER September 2012 CA Nimsoft For Network Monitoring Table of Contents EXECUTIVE SUMMARY 3 Solution overview 3 CA Nimsoft Monitor specialized probes 3 Network and application connectivity probe

More information

Using WhatsUp IP Address Manager 1.0

Using WhatsUp IP Address Manager 1.0 Using WhatsUp IP Address Manager 1.0 Contents Table of Contents Welcome to WhatsUp IP Address Manager Finding more information and updates... 1 Sending feedback... 2 Installing and Licensing IP Address

More information

IBM Tivoli Network Manager software

IBM Tivoli Network Manager software Perform real-time network discovery, topology visualization and root-cause analysis IBM Tivoli Network Manager software Highlights Help increase the availability and performance of critical business services

More information

Network Monitoring with SNMP

Network Monitoring with SNMP Network Monitoring with SNMP This document describes how SNMP is used in WhatsUp Gold v11 and provides examples on how to configure performance, active, and passive monitors. Introduction SNMP (Simple

More information

IBM Tivoli Network Manager 3.8

IBM Tivoli Network Manager 3.8 IBM Tivoli Network Manager 3.8 Configuring initial discovery 2010 IBM Corporation Welcome to this module for IBM Tivoli Network Manager 3.8 Configuring initial discovery. configuring_discovery.ppt Page

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7 Contents Introduction--1 Product definition 1 Implementing SNMP 2 Integrating SNMP into the user interface 3 Components of OPC SNMP Gateway 4 How to Obtain an OPC License--5 Creating a System Code 5 Entering

More information

Kaseya 2. User Guide. Version 7.0. English

Kaseya 2. User Guide. Version 7.0. English Kaseya 2 Monitoring Configuration User Guide Version 7.0 English September 3, 2014 Agreement The purchase and use of all Software and Services is subject to the Agreement as defined in Kaseya s Click-Accept

More information

Network Agent Quick Start

Network Agent Quick Start Network Agent Quick Start Topic 50500 Network Agent Quick Start Updated 17-Sep-2013 Applies To: Web Filter, Web Security, Web Security Gateway, and Web Security Gateway Anywhere, v7.7 and 7.8 Websense

More information

Assets, Groups & Networks

Assets, Groups & Networks Complete. Simple. Affordable Copyright 2014 AlienVault. All rights reserved. AlienVault, AlienVault Unified Security Management, AlienVault USM, AlienVault Open Threat Exchange, AlienVault OTX, Open Threat

More information

Rapid Assessment Key v2 Technical Overview

Rapid Assessment Key v2 Technical Overview Rapid Assessment Key v2 Technical Overview Overview The Rapid Assessment Key v2 is an extremely easy to use USB device that quickly collects data on networked imaging devices. The key allows office equipment

More information

DEPLOYMENT GUIDE Version 1.1. Deploying F5 with Oracle Application Server 10g

DEPLOYMENT GUIDE Version 1.1. Deploying F5 with Oracle Application Server 10g DEPLOYMENT GUIDE Version 1.1 Deploying F5 with Oracle Application Server 10g Table of Contents Table of Contents Introducing the F5 and Oracle 10g configuration Prerequisites and configuration notes...1-1

More information

WhatsUpGold. v3.0. WhatsConnected User Guide

WhatsUpGold. v3.0. WhatsConnected User Guide WhatsUpGold v3.0 WhatsConnected User Guide Contents CHAPTER 1 Welcome to WhatsConnected Finding more information and updates... 2 Sending feedback... 3 CHAPTER 2 Installing and Configuring WhatsConnected

More information

ACP ThinManager Tech Notes Troubleshooting Guide

ACP ThinManager Tech Notes Troubleshooting Guide ACP ThinManager Tech Notes Troubleshooting Guide Use the F1 button on any page of a ThinManager wizard to launch Help for that page. Visit www.thinmanager.com/technotes/ to download the manual, manual

More information

Configuring SSL VPN on the Cisco ISA500 Security Appliance

Configuring SSL VPN on the Cisco ISA500 Security Appliance Application Note Configuring SSL VPN on the Cisco ISA500 Security Appliance This application note describes how to configure SSL VPN on the Cisco ISA500 security appliance. This document includes these

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS FREQUENTLY ASKED QUESTIONS Secure Bytes, October 2011 This document is confidential and for the use of a Secure Bytes client only. The information contained herein is the property of Secure Bytes and may

More information

GLBP - Gateway Load Balancing Protocol

GLBP - Gateway Load Balancing Protocol GLBP - Gateway Load Balancing Protocol Gateway Load Balancing Protocol (GLBP) protects data traffic from a failed router or circuit, like Hot Standby Router Protocol (HSRP) and Virtual Router Redundancy

More information

CA Spectrum. Microsoft MOM and SCOM Integration Guide. Release 9.4

CA Spectrum. Microsoft MOM and SCOM Integration Guide. Release 9.4 CA Spectrum Microsoft MOM and SCOM Integration Guide Release 9.4 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation

More information

6.0. Getting Started Guide

6.0. Getting Started Guide 6.0 Getting Started Guide Netmon Getting Started Guide 2 Contents Contents... 2 Appliance Installation... 3 IP Address Assignment (Optional)... 3 Logging In For the First Time... 5 Initial Setup... 6 License

More information

Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent?

Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent? What is Network Agent? The Websense Network Agent software component uses sniffer technology to monitor all of the internet traffic on the network machines that you assign to it. Network Agent filters

More information

Configuring and Managing Token Ring Switches Using Cisco s Network Management Products

Configuring and Managing Token Ring Switches Using Cisco s Network Management Products Configuring and Managing Token Ring Switches Using Cisco s Network Management Products CHAPTER 12 Cisco offers several network management applications that you can use to manage your Catalyst Token Ring

More information

Network Monitoring with SNMP

Network Monitoring with SNMP Network Monitoring with SNMP This paper describes how SNMP is used in WhatsUp- Professional and provides specific examples on how to configure performance, active, and passive monitors. Introduction SNMP

More information

Cisco Prime Collaboration Deployment Troubleshooting

Cisco Prime Collaboration Deployment Troubleshooting Cisco Prime Collaboration Deployment Troubleshooting Increase Disk Space for Migrations, page 1 General Troubleshooting Issues, page 2 Errors Seen in View Log, page 2 Lock Errors, page 6 NFS Datastores,

More information

CA Spectrum and CA Performance Center

CA Spectrum and CA Performance Center CA Spectrum and CA Performance Center Integration Guide CA Spectrum Release 9.3 - CA Performance Center r2.3.00 This Documentation, which includes embedded help systems and electronically distributed materials,

More information

White Paper. The Ten Features Your Web Application Monitoring Software Must Have. Executive Summary

White Paper. The Ten Features Your Web Application Monitoring Software Must Have. Executive Summary White Paper The Ten Features Your Web Application Monitoring Software Must Have Executive Summary It s hard to find an important business application that doesn t have a web-based version available and

More information

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Using Device Discovery

Using Device Discovery 2 CHAPTER You can use Active Discovery to scan your network for new monitors (Active Monitors and Performance Monitors) and devices on a regular basis. Newly discovered items are added to the Active Discovery

More information

Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1.

Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1. Avaya Solution & Interoperability Test Lab Application Notes for Configuring Dorado Software Redcell Enterprise Bundle using SNMP with Avaya Communication Manager - Issue 1.0 Abstract These Application

More information

orrelog Ping Monitor Adapter Software Users Manual

orrelog Ping Monitor Adapter Software Users Manual orrelog Ping Monitor Adapter Software Users Manual http://www.correlog.com mailto:info@correlog.com CorreLog, Ping Monitor Users Manual Copyright 2008-2015, CorreLog, Inc. All rights reserved. No part

More information

The Discovery Wizard now provides the ability to create SNMP Setups that can be selected for individual discoveries. An SNMP Setup specifies:

The Discovery Wizard now provides the ability to create SNMP Setups that can be selected for individual discoveries. An SNMP Setup specifies: Using Discovery 1/3 Using Discovery Open the Discovery application by clicking Discovery in the Task Bar, selecting Discovery from the Applications menu, or by clicking the Discovery icon in the Topology

More information

WHITE PAPER OCTOBER 2014. CA Unified Infrastructure Management for Networks

WHITE PAPER OCTOBER 2014. CA Unified Infrastructure Management for Networks WHITE PAPER OCTOBER 2014 CA Unified Infrastructure Management for Networks 2 WHITE PAPER: CA UNIFIED INFRASTRUCTURE MANAGEMENT FOR NETWORKS ca.com Table of Contents Solution Overview 3 Specialized Probes

More information

Integration Guide. Help Desk Authority, Perspective and sl360. 1.800.424.9411 www.scriptlogic.com

Integration Guide. Help Desk Authority, Perspective and sl360. 1.800.424.9411 www.scriptlogic.com Integration Guide Help Desk Authority, Perspective and sl360 1.800.424.9411 www.scriptlogic.com Table of Contents Introduction... 3 Product Overview... 3 Benefits of Product Integration... 3 Advanced Help

More information

Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1

Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1 Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1 This document supports the version of each product listed and supports all subsequent versions until the document

More information

Kaseya 2. User Guide. Version R8. English

Kaseya 2. User Guide. Version R8. English Kaseya 2 Discovery User Guide Version R8 English September 19, 2014 Agreement The purchase and use of all Software and Services is subject to the Agreement as defined in Kaseya s Click-Accept EULATOS as

More information

ehealth Resource Discovery Guide

ehealth Resource Discovery Guide ehealth Resource Discovery Guide MN-ADMDISGD-001 October 2006 This documentation (the "Documentation") and related computer software program (the "Software") (hereinafter collectively referred to as the

More information

Freshservice Discovery Probe User Guide

Freshservice Discovery Probe User Guide Freshservice Discovery Probe User Guide 1. What is Freshservice Discovery Probe? 1.1 What details does Probe fetch? 1.2 How does Probe fetch the information? 2. What are the minimum system requirements

More information

Providing Patch Management with N-central. Version 9.1

Providing Patch Management with N-central. Version 9.1 Providing Patch Management with N-central Version 9.1 Contents Patch Management 4 Introduction 4 Monitoring for Missing Patches 4 Setting up Patch Management in N-central 5 Adding a WSUS Server to N-central

More information

Enhanced Connector Applications SupportPac VP01 for IBM WebSphere Business Events 3.0.0

Enhanced Connector Applications SupportPac VP01 for IBM WebSphere Business Events 3.0.0 Enhanced Connector Applications SupportPac VP01 for IBM WebSphere Business Events 3.0.0 Third edition (May 2012). Copyright International Business Machines Corporation 2012. US Government Users Restricted

More information

Installing, Uninstalling, and Upgrading Service Monitor

Installing, Uninstalling, and Upgrading Service Monitor CHAPTER 2 Installing, Uninstalling, and Upgrading Service Monitor This section contains the following topics: Preparing to Install Service Monitor, page 2-1 Installing Cisco Unified Service Monitor, page

More information

IBM Security QRadar SIEM Version 7.1.0 MR1. Log Sources User Guide

IBM Security QRadar SIEM Version 7.1.0 MR1. Log Sources User Guide IBM Security QRadar SIEM Version 7.1.0 MR1 Log Sources User Guide Note: Before using this information and the product that it supports, read the information in Notices and Trademarks on page 108. Copyright

More information

Discovering Devices CHAPTER

Discovering Devices CHAPTER CHAPTER 11 The Cisco Prime Collaboration Manager discovery process involves three phases: Access-level discovery Cisco Prime CM verifies the SNMP, HTTP, CLI, and JTAPI credentials on the devices. For endpoints

More information

WEBTITAN CLOUD. User Identification Guide BLOCK WEB THREATS BOOST PRODUCTIVITY REDUCE LIABILITIES

WEBTITAN CLOUD. User Identification Guide BLOCK WEB THREATS BOOST PRODUCTIVITY REDUCE LIABILITIES BLOCK WEB THREATS BOOST PRODUCTIVITY REDUCE LIABILITIES WEBTITAN CLOUD User Identification Guide This guide explains how to install and configure the WebTitan Cloud Active Directory components required

More information

Cisco Change Management: Best Practices White Paper

Cisco Change Management: Best Practices White Paper Table of Contents Change Management: Best Practices White Paper...1 Introduction...1 Critical Steps for Creating a Change Management Process...1 Planning for Change...1 Managing Change...1 High Level Process

More information

WhatsUp Gold v11 Features Overview

WhatsUp Gold v11 Features Overview WhatsUp Gold v11 Features Overview This guide provides an overview of the core functionality of WhatsUp Gold v11, and introduces interesting features and processes that help users maximize productivity

More information

Netflow Collection with AlienVault Alienvault 2013

Netflow Collection with AlienVault Alienvault 2013 Netflow Collection with AlienVault Alienvault 2013 CONFIGURE Configuring NetFlow Capture of TCP/IP Traffic from an AlienVault Sensor or Remote Hardware Level: Beginner to Intermediate Netflow Collection

More information

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client.

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client. WatchGuard SSL v3.2 Release Notes Supported Devices SSL 100 and 560 WatchGuard SSL OS Build 355419 Revision Date January 28, 2013 Introduction WatchGuard is pleased to announce the release of WatchGuard

More information

Setting up Support for CiscoWorks ANI Server

Setting up Support for CiscoWorks ANI Server CHAPTER 6 Setting up Support for CiscoWorks ANI Server The CiscoWorks Server includes tools required to properly set up the server to support other CiscoWorks applications. These features include: Configuring

More information

Deploying the BIG-IP System v10 with Oracle Application Server 10g R2

Deploying the BIG-IP System v10 with Oracle Application Server 10g R2 DEPLOYMENT GUIDE Deploying the BIG-IP System v10 with Oracle Application Server 10g R2 Version 1.1 Table of Contents Table of Contents Deploying the BIG-IP system v10 with Oracle s Application Server 10g

More information

Guideline for setting up a functional VPN

Guideline for setting up a functional VPN Guideline for setting up a functional VPN Why do I want a VPN? VPN by definition creates a private, trusted network across an untrusted medium. It allows you to connect offices and people from around the

More information

IBM Security QRadar Vulnerability Manager Version 7.2.1. User Guide

IBM Security QRadar Vulnerability Manager Version 7.2.1. User Guide IBM Security QRadar Vulnerability Manager Version 7.2.1 User Guide Note Before using this information and the product that it supports, read the information in Notices on page 61. Copyright IBM Corporation

More information

Net Inspector 2015 GETTING STARTED GUIDE. MG-SOFT Corporation. Document published on October 16, 2015. (Document Version: 10.6)

Net Inspector 2015 GETTING STARTED GUIDE. MG-SOFT Corporation. Document published on October 16, 2015. (Document Version: 10.6) MG-SOFT Corporation Net Inspector 2015 GETTING STARTED GUIDE (Document Version: 10.6) Document published on October 16, 2015 Copyright 1995-2015 MG-SOFT Corporation Introduction In order to improve the

More information

Architecture and Data Flow Overview. BlackBerry Enterprise Service 10 721-08877-123 Version: 10.2. Quick Reference

Architecture and Data Flow Overview. BlackBerry Enterprise Service 10 721-08877-123 Version: 10.2. Quick Reference Architecture and Data Flow Overview BlackBerry Enterprise Service 10 721-08877-123 Version: Quick Reference Published: 2013-11-28 SWD-20131128130321045 Contents Key components of BlackBerry Enterprise

More information

IBM. Netcool /Proviso 4.3-X. Tivoli. NetFlow IPFIX 2.4.1.0 Technology Pack User s Guide. Document Revision R2E1

IBM. Netcool /Proviso 4.3-X. Tivoli. NetFlow IPFIX 2.4.1.0 Technology Pack User s Guide. Document Revision R2E1 Tivoli Netcool /Proviso 4.3-X IBM Document Revision R2E1 NetFlow IPFIX 2.4.1.0 Technology Pack User s Guide Notices This information was developed for products and services offered in the U.S.A. IBM may

More information

IP Address, Domain and Hostname for IM and Presence Service on Cisco Unified Communications Manager, Release 9.1(1)

IP Address, Domain and Hostname for IM and Presence Service on Cisco Unified Communications Manager, Release 9.1(1) IP Address, Domain and Hostname for IM and Presence Service on Cisco Unified Communications Manager, Release 9.1(1) November 28, 2012 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San

More information

Providing Patch Management With N-central. Version 7.2

Providing Patch Management With N-central. Version 7.2 Providing Patch Management With N-central Version 7.2 Contents Patch Management 3 Introduction 3 Monitoring for Missing Patches 3 Setting up Patch Management in N-central 4 Adding a WSUS Server to N-central

More information

Pharos Control User Guide

Pharos Control User Guide Outdoor Wireless Solution Pharos Control User Guide REV1.0.0 1910011083 Contents Contents... I Chapter 1 Quick Start Guide... 1 1.1 Introduction... 1 1.2 Installation... 1 1.3 Before Login... 8 Chapter

More information

mbits Network Operations Centrec

mbits Network Operations Centrec mbits Network Operations Centrec The mbits Network Operations Centre (NOC) is co-located and fully operationally integrated with the mbits Service Desk. The NOC is staffed by fulltime mbits employees,

More information

How To Use A Help Desk With A Pnettrap On A Pc Or Mac Or Mac (For A Laptop)

How To Use A Help Desk With A Pnettrap On A Pc Or Mac Or Mac (For A Laptop) Integration Guide Help Desk Authority, PacketTrap and sl360 1.800.424.9411 www.scriptlogic.com 2010 ScriptLogic Corporation ALL RIGHTS RESERVED. ScriptLogic, the ScriptLogic logo, Help Desk Authority and

More information

WhatsUp Gold v11 Features Overview

WhatsUp Gold v11 Features Overview WhatsUp Gold v11 Features Overview This guide provides an overview of the core functionality of WhatsUp Gold v11, and introduces interesting features and processes that help users maximize productivity

More information

DEPLOYMENT GUIDE Version 2.1. Deploying F5 with Microsoft SharePoint 2010

DEPLOYMENT GUIDE Version 2.1. Deploying F5 with Microsoft SharePoint 2010 DEPLOYMENT GUIDE Version 2.1 Deploying F5 with Microsoft SharePoint 2010 Table of Contents Table of Contents Introducing the F5 Deployment Guide for Microsoft SharePoint 2010 Prerequisites and configuration

More information

Print Audit Facilities Manager Technical Overview

Print Audit Facilities Manager Technical Overview Print Audit Facilities Manager Technical Overview Print Audit Facilities Manager is a powerful, easy to use tool designed to remotely collect meter reads, automate supplies fulfilment and report service

More information

CA Spectrum. Certification User Guide. Release 9.4

CA Spectrum. Certification User Guide. Release 9.4 CA Spectrum Certification User Guide Release 9.4 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation ) is for

More information

Appendix D: Configuring Firewalls and Network Address Translation

Appendix D: Configuring Firewalls and Network Address Translation Appendix D: Configuring Firewalls and Network Address Translation The configuration information in this appendix will help the network administrator plan and configure the network architecture for Everserve.

More information

Leveraging Best Practices for SolarWinds IP Address Manager

Leveraging Best Practices for SolarWinds IP Address Manager Leveraging Best Practices for SolarWinds IP Address Manager Share: Leveraging Best Practices for SolarWinds IPAM SolarWinds IP Address Manager (IPAM) is a comprehensive IP address management solution that

More information

HP IMC User Behavior Auditor

HP IMC User Behavior Auditor HP IMC User Behavior Auditor Administrator Guide Abstract This guide describes the User Behavior Auditor (UBA), an add-on service module of the HP Intelligent Management Center. UBA is designed for IMC

More information

Unicenter Workload Control Center r1 SP4. Server Status Troubleshooting Guide

Unicenter Workload Control Center r1 SP4. Server Status Troubleshooting Guide Unicenter Workload Control Center r1 SP4 Server Status Troubleshooting Guide Table of Contents 1 Introduction 3 2 Information Page 3 3 Server Status Portlet 3 3.1 Configuration User Usage... 3 3.2 Troubleshooting

More information

NETWORK PRINT MONITOR User Guide

NETWORK PRINT MONITOR User Guide NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device

Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device Advanced Guide for Configuring SNMPc to Manage Any SNMP Enabled Device SNMPc supports many devices straight out of the box. Its generic support for device classes such as Switches, Routers and Servers

More information

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc.

Legal Notes. Regarding Trademarks. 2012 KYOCERA Document Solutions Inc. Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

CA Spectrum Active Directory and Exchange Server Manager

CA Spectrum Active Directory and Exchange Server Manager CA Spectrum Active Directory and Exchange Server Manager Solution Guide Release 9.2.2 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred

More information

Using SolarWinds Orion for Cisco Assessments

Using SolarWinds Orion for Cisco Assessments Using SolarWinds Orion for Cisco Assessments Cisco Network Assessments Registering Your Assessment... 1 Installing SolarWinds Orion Network Performance Monitor... 1 Discovering Your Network... 1 Polling

More information

Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent?

Quick Start for Network Agent. 5-Step Quick Start. What is Network Agent? What is Network Agent? Websense Network Agent software monitors all internet traffic on the machines that you assign to it. Network Agent filters HTTP traffic and more than 70 other popular internet protocols,

More information

Detecting rogue systems

Detecting rogue systems Product Guide Revision A McAfee Rogue System Detection 4.7.1 For use with epolicy Orchestrator 4.6.3-5.0.0 Software Detecting rogue systems Unprotected systems, referred to as rogue systems, are often

More information

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link: TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link: ftp://ftp.software.ibm.com/storage/tivoli-storagemanagement/maintenance/client/v6r2/windows/x32/v623/

More information

DS License Server. Installation and Configuration Guide. 3DEXPERIENCE R2014x

DS License Server. Installation and Configuration Guide. 3DEXPERIENCE R2014x DS License Server Installation and Configuration Guide 3DEXPERIENCE R2014x Contains JAVA SE RUNTIME ENVIRONMENT (JRE) VERSION 7 Contains IBM(R) 64-bit SDK for AIX(TM), Java(TM) Technology Edition, Version

More information

ehealth Integration for Cisco VPN Solutions Center User Guide

ehealth Integration for Cisco VPN Solutions Center User Guide ehealth Integration for Cisco VPN Solutions Center User Guide MN-NHVPNSC-001 June 2003 Important Notice Concord Communications, Inc., ehealth, ehealth Suite, the Concord Logo, eroi, AdvantEDGE, SystemEDGE,

More information

Change Management for Rational DOORS User s Guide

Change Management for Rational DOORS User s Guide Change Management for Rational DOORS User s Guide Before using this information, read the general information under Appendix: Notices on page 58. This edition applies to Change Management for Rational

More information

ALTIRIS Software Delivery Solution for Windows 6.1 SP3 Product Guide

ALTIRIS Software Delivery Solution for Windows 6.1 SP3 Product Guide ALTIRIS Software Delivery Solution for Windows 6.1 SP3 Product Guide Notice Altiris Software Delivery Solution for Windows 6.1 SP3 Product Guide 2007 Altiris, Inc. All rights reserved. Document Date: February

More information

HP LeftHand SAN Solutions

HP LeftHand SAN Solutions HP LeftHand SAN Solutions Support Document Applications Notes Best Practices for Using SolarWinds' ORION to Monitor SANiQ Performance Legal Notices Warranty The only warranties for HP products and services

More information

DiskPulse DISK CHANGE MONITOR

DiskPulse DISK CHANGE MONITOR DiskPulse DISK CHANGE MONITOR User Manual Version 7.9 Oct 2015 www.diskpulse.com info@flexense.com 1 1 DiskPulse Overview...3 2 DiskPulse Product Versions...5 3 Using Desktop Product Version...6 3.1 Product

More information

How To Understand and Configure Your Network for IntraVUE

How To Understand and Configure Your Network for IntraVUE How To Understand and Configure Your Network for IntraVUE Summary This document attempts to standardize the methods used to configure Intrauve in situations where there is little or no understanding of

More information

CA Nimsoft Monitor. Probe Guide for Internet Control Message Protocol Ping. icmp v1.1 series

CA Nimsoft Monitor. Probe Guide for Internet Control Message Protocol Ping. icmp v1.1 series CA Nimsoft Monitor Probe Guide for Internet Control Message Protocol Ping icmp v1.1 series CA Nimsoft Monitor Copyright Notice This online help system (the "System") is for your informational purposes

More information

McAfee Web Gateway 7.4.1

McAfee Web Gateway 7.4.1 Release Notes Revision B McAfee Web Gateway 7.4.1 Contents About this release New features and enhancements Resolved issues Installation instructions Known issues Find product documentation About this

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

Troubleshooting Failover in Cisco Unity 8.x

Troubleshooting Failover in Cisco Unity 8.x CHAPTER 16 Troubleshooting Failover in Cisco Unity 8.x This chapter describes methods for troubleshooting Cisco Unity failover. See the following sections: Failover Configuration Wizard Does Not Finish

More information

RUNNING A HELPDESK CONTENTS. using HP Web Jetadmin

RUNNING A HELPDESK CONTENTS. using HP Web Jetadmin RUNNING A HELPDESK using HP Web Jetadmin CONTENTS Overview... 2 Helpdesk examples... 2 Viewing devices... 2 Quick Device Discovery... 3 Search... 3 Filters... 3 Columns... 4 Device Groups... 4 Troubleshooting

More information

How To Use The Correlog With The Cpl Powerpoint Powerpoint Cpl.Org Powerpoint.Org (Powerpoint) Powerpoint (Powerplst) And Powerpoint 2 (Powerstation) (Powerpoints) (Operations

How To Use The Correlog With The Cpl Powerpoint Powerpoint Cpl.Org Powerpoint.Org (Powerpoint) Powerpoint (Powerplst) And Powerpoint 2 (Powerstation) (Powerpoints) (Operations orrelog SQL Table Monitor Adapter Users Manual http://www.correlog.com mailto:info@correlog.com CorreLog, SQL Table Monitor Users Manual Copyright 2008-2015, CorreLog, Inc. All rights reserved. No part

More information

User's Guide - Beta 1 Draft

User's Guide - Beta 1 Draft IBM Tivoli Composite Application Manager for Microsoft Applications: Microsoft Cluster Server Agent vnext User's Guide - Beta 1 Draft SC27-2316-05 IBM Tivoli Composite Application Manager for Microsoft

More information

Using RADIUS Agent for Transparent User Identification

Using RADIUS Agent for Transparent User Identification Using RADIUS Agent for Transparent User Identification Using RADIUS Agent Web Security Solutions Version 7.7, 7.8 Websense RADIUS Agent works together with the RADIUS server and RADIUS clients in your

More information

Integrating Autotask Service Desk Ticketing with the Cisco OnPlus Portal

Integrating Autotask Service Desk Ticketing with the Cisco OnPlus Portal Integrating Autotask Service Desk Ticketing with the Cisco OnPlus Portal This Application Note provides instructions for configuring Apps settings on the Cisco OnPlus Portal and Autotask application settings

More information

End User Setup and Handling

End User Setup and Handling on IM and Presence Service, page 1 Authorization Policy Setup On IM and Presence Service, page 1 Bulk Rename User Contact IDs, page 4 Bulk Export User Contact Lists, page 5 Bulk Export Non-Presence Contact

More information

Assignment One. ITN534 Network Management. Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition)

Assignment One. ITN534 Network Management. Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition) Assignment One ITN534 Network Management Title: Report on an Integrated Network Management Product (Solar winds 2001 Engineer s Edition) Unit Co-coordinator, Mr. Neville Richter By, Vijayakrishnan Pasupathinathan

More information

HP Data Protector Integration with Autonomy IDOL Server

HP Data Protector Integration with Autonomy IDOL Server HP Data Protector Integration with Autonomy IDOL Server Introducing e-discovery for HP Data Protector environments Technical white paper Table of contents Summary... 2 Introduction... 2 Integration concepts...

More information

WebSphere Business Monitor

WebSphere Business Monitor WebSphere Business Monitor Debugger 2010 IBM Corporation This presentation provides an overview of the monitor model debugger in WebSphere Business Monitor. WBPM_Monitor_Debugger.ppt Page 1 of 23 Goals

More information

PANDORA FMS NETWORK DEVICES MONITORING

PANDORA FMS NETWORK DEVICES MONITORING NETWORK DEVICES MONITORING pag. 2 INTRODUCTION This document aims to explain how Pandora FMS can monitor all the network devices available in the market, like Routers, Switches, Modems, Access points,

More information

vrealize Operations Manager Customization and Administration Guide

vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager Customization and Administration Guide vrealize Operations Manager 6.0.1 This document supports the version of each product listed and supports all subsequent versions until

More information

Using IPM to Measure Network Performance

Using IPM to Measure Network Performance CHAPTER 3 Using IPM to Measure Network Performance This chapter provides details on using IPM to measure latency, jitter, availability, packet loss, and errors. It includes the following sections: Measuring

More information