User s Guide Digi CM

Size: px
Start display at page:

Download "User s Guide Digi CM"

Transcription

1 User s Guide Digi CM _G

2

3 Digi International Inc All rights reserved. Digi, Digi International, the Digi logo, Digi CM, the Making Device Networking Easy logo, Digi One, and RealPort are trademarks or registered trademarks of Digi International, Inc. in the United States and other countries worldwide. All other trademarks are the property of their respective owners. Microsoft Windows Server 2003 is a trademark of Microsoft Corporation.

4 4

5 Contents Chapter 1 Introduction Digi CM Model Support...13 Feature Overview...13 Feature Summary...13 User Groups...15 Root and Admin Usernames and Passwords...15 Adding Port Administrators and Users...15 Access Lists...15 Ways to Configure the Digi CM...15 Web Interface Configuration Menu Command Line Interface Ways of Accessing the Digi CM Ports: Overview...17 Web Interface Access Menu...17 Port Access Menu...19 Direct Port Access...20 Custom Menus...20 Port Escape Menu...21 Description of Fields SNMP...23 Saving and Applying Changes...23 One Step: Save and Apply Changes Two-Step: Save to Flash and then Apply Changes Automatic Device Recognition...23 Locator Light...24 Chapter 2 Getting Started Introduction...25 Assigning IP Settings from the Console Port...25 Configuring for SSH...27 Options Configuring the Port Access Menu for SSH Configuring a Port for SSH Adding, Editing, and Removing Users...29 Procedure About Shell Options Chapter 3 Installing and Configuring PC Cards Introduction...31 Compatible PC Cards...31 Adding a Compact-flash Card...31 Adding a Network Card...32 Contents 5

6 Adding a Wireless LAN Card...33 Adding a Serial Modem...34 Chapter 4 System Status and Port Logging Introduction...37 System Status & Log...37 System Information IP Information Enabling Log Storage Location...38 Enable NFS Server Alert for NFS Server Disconnect Enable SYSLOG Server Enable a Compact-flash Card Enable the Digi CM Unit s Memory Configuring System Logging...41 Viewing System Logs Configure Port Logging...43 Viewing Port Logs Chapter 5 Configuring Ports Introduction...47 Enabling and Disabling the Ports...47 RealPort Support...47 Resetting Ports...49 Reset Individual Port Settings Port Title...49 Configuring Automatic Device Recognition...49 Apply all Ports Settings...51 Host Mode Configuration...52 Console Server Mode Terminal Server Mode Dial-In Modem Mode Dial-In Terminal Server Configuring Host Mode...54 Supported Protocols...56 Serial Port Parameters...56 DTR Behavior Inter-character Timeout Specialty Use of Port -When Data is Processed in Chunks...57 Remote Ports...58 Configure Remote Ports Accessing a remote port Chapter 6 Alerts and Notifications Introduction...61 Configuring SMTP Alerts...62 SNMP Information...62 Traps...63 Configuring SNMP...63 Managing the SNMP Protocol Contents

7 Configuring Port Event Handling...65 Config Alerts for Automatic Device Recognition (ADR)...67 Chapter 7 User Administration Administering Users...69 Required Privileges Procedure To Add an Access List to the Digi CM Unit Chapter 8 Configuring Security and Authentication Introduction...73 Configuring Network IP Filtering...73 Configuring User Access Control...77 Configure User Access Privileges Restrict a User s Privileges Change the Privileges of an Access List Sniff Session Security Profile...82 System Security Password Security Authentication...84 Configuring Authentication Methods for Port Access...84 Configuring Authentication for the Web Server...85 LDAP Authentication Custom PAM Module Chapter 9 Custom and Default Menus Introduction...89 Making Custom Menus...89 Adding Users Creating Menu Names Adding Menu Items Assigning Users to a Menu Default Menu...92 Port Access Menu Chapter 10 Microsoft SAC Support About the Digi CM Unit s Support for Microsoft Windows Server Setup Overview...96 Setting Up the Windows Server 2003 Port...96 Command Syntax Command Example Setting Up the Digi CM Unit for SAC Support...96 Accessing the Windows Server 2003 Console Port from the Digi CM Unit s GUI98 Chapter 11 Configuring Virtual KVM Introduction An Example Configuration Contents 7

8 Virtual KVM Protocols Using Virtual KVM with Remote Desktop Protocol Configuring Connecting to a system through Virtual KVM using Remote Desktop Protocol 104 Using Virtual KVM with VNC Protocol Configuring Connecting to a system through Virtual KVM using VNC Using Virtual KVM with X Window System Protocol and XManager Software Configuring Connecting to a system through Virtual KVM using Xmanager Virtual KVM Assistant How the Virtual KVM Assistant Works User Client PC platforms Supported Installing Programs for Virtual KVM Remote Desktop Protocol VNC Viewer Xmanager Chapter 12 Rackable Systems Management Card Introduction Set up Setup of the Digi CM Unit to Support the Rackable Systems Management Card 117 Configure Serial Port Communication Settings: Assign a Port Name: Accessing the Rackable Systems Management Card from the Digi CM Unit s User Interface Chapter 13 Configuring Remote Dial-In Access Introduction Configuring for Dial-In Modem Access Adding a PC Modem Configuring for Dial-In Terminal Server Access Chapter 14 Power Controller Introduction Installing Power Controller Configuring Power Controller Configure the Serial Port Parameters to Match the Power Controller Add the Power Controller Setting Alarms and Thresholds Outlet Configuration User Access for Power Controller Configuring to Allow Specific Users Access Configuring to Restrict Specific Users Power Controller Management Cascading Multiple Digi RPM Units Chapter 15 Port Clustering Introduction Contents

9 Configuring Port Clustering Assigning Master Clustering Mode Configure Slaves to Join a Cluster Advanced Clustering Configuration Accessing the Cluster Ports Chapter 16 System Administration Introduction Upgrading the Firmware Web Interface Configuration Management Automatically Saving the Configuration Automatically Upgrading the Digi CM Unit s Firmware or Configuration using TFTP 147 DHCP Directly Configure the TFTP Server and the Name of the hash File The Structure of the Hash File Resetting Factory Defaults Setting Date and Time Configuring a Host Name Chapter 17 Command Line Interface Introduction Linux Commands Important File Locations Default Script Booting Sequence Config Files User Storage Space Example Scripts User Administration Locator LED Script Chapter 18 Configuration Menu Introduction to the Configuration Menu Accessing the Configuration Menu Configuring SSH Adding, Editing, and Removing Users Adding and Configuring a PC Card Host Mode Configuration Port Parameters Port Access Menu System Logging Configure the System Log Device Configure System Logging Configuring SNMP Configuring SMTP Contents 9

10 Network IP Filtering Port IP Filtering Sniff Sessions Viewing A Sniff Session Field Descriptions for Sniff Sessions Authentication Upload Server Certificate OpenSSL(SSLeay) Simple CA Usage - Install Openssl Make Root CA (Certificate Authority for Self-signed) Making a Certificate Request Signing a Certificate Request Make Certificate for the Digi CM Unit Dial-in Modem Access Dial-in Terminal Server Access Clustering Firmware Upgrade Restoring Factory Defaults Setting Date and Time Accessing the Boot Loader Program Hardware Test Menu Disaster Recovery Chapter 19 Hardware Information Introduction Hardware Specifications Digi CM Digi CM 16 and Digi CM Digi CM 8 AC Powered LED Indicators About Serial Port Cabling Serial Port Pinouts Cable Adapters DB-25 Male Console Adapter DB-9 Female Console Adapter DB-25 Female Console Adapter DB-25 Female to RJ-45 Pin Assignments DB-25 Male Modem Adapter (Digi 8-pack reorder P/N ) DB-25 Male Modem to RJ-45 Pin Assignment DB-9 Male Modem Adapter (Digi 8-pack reorder P/N ) DB-9 Male Modem to RJ-45 Pin Assignment Ethernet Pinouts Rack Mounting Installation Rack Mounting Safety Precautions Chapter 20 Certifications Safety Working Inside the Digi CM Unit Replacing the Battery Rack Mounting Installation Considerations Contents

11 Environmental Considerations and Cautions Safety Instructions Emissions Immunity Solaris Ready Contents 11

12

13 Introduction Chapter 1 Introduction Digi CM Model Support This manual offers information on thedigi CM 8-port, 16-port, 32-port, and 48- port models. Feature Overview With the Digi CM unit, administrators can securely monitor and control servers, routers, switches, and other network devices from anywhere on the corporate TCP/IP network, over the Internet, or through dial-up modem connections, even when the server is unavailable through the network. The Digi CM employs SSHv2 encryption, to keep server access passwords safe from hackers, and supports all popular SSH clients, as well as secure access from any Java-enabled browser. It is the first console server to provide a secure graphical user interface for easy out-of-band management of Microsoft Windows Server 2003 systems. It connects to serial console ports using standard CAT5 cables, eliminating the hassles of custom cabling. In addition, the Digi CM unit offers a PCMCIA card slot, for adding dialup modems or wireless network cards. Flash memory cards can be used to save port logs and backup configuration files. The Digi CM unit is available in 8-, 16-, 32- and 48-port models, in a 1U rackmount form factor. Feature Summary Category Security Authentication Feature SSH v2 server and client SSL IP Filtering Central access to security parameters via the Security Profile including network, port, and password securities. TACACS+ RADIUS LDAP Custom PAM modules Kerberos User access per port Local user database Chapter 1 13

14 Feature Summary Category Management Data Capture Port Access PC Card Support Other Features Feature Command line WEB --HTTP/HTTPS SNMP Custom applications Port Triggers and Alerts Multi level menus Advanced Device Discover Protocol (ADDP) for locating the device on the network Integrated power management and control Automatic Device Recognition Local port logging External logging (syslog, NFS, secure NFS, PC card) Telnet/SSH with custom menu Reverse Telnet/SSH HTTP/HTTPS Raw TCP Port escape menu CompactFlash memory card Wireless LAN adapter (802.11b) Ethernet LAN adapter PSTN/CDMA modem card See for more information. RealPort Solaris Ready Multiple users per port Remote ports Access lists per port Flash upgrade able SSH sessions simultaneously on all ports Secure Clustering - Single IP for multiple Digi CM devices IP addresses per port Automated TFTP firmware and configuration update upon boot RSA SecurID support using RADIUS Find Me locator light (Digi CM 48-port) 14 Chapter 1

15 Introduction User Groups The Digi CM unit comes with 4 built-in user groups, pre-defined by roles or access levels. The following table lists the 4 user groups, their access rights, and default user names. The Digi CM unit supports access lists for user privileges. These lists can contain multiple users and port rights. If e.g. you have multiple people responsible for the Sun Servers in your company and you want to give them identical access rights you can create a "Sun-admin" access list. Assign this access list rights to every port that is attached to a Sun Server and add all the Sun administrators to the "Sun-admin" Access List. Group Access Privileges Configuration Privileges Defaults Ports Command Line Ports System Login Password Root yes yes yes yes root dbps System Admin yes yes (read only) yes yes admin admin Port Admin yes no yes no - - User yes no no no - - Root and Admin Usernames and Passwords The Digi CM unit comes with two default users; root and system admin. The user names of the the Digi CM unit are case sensitive. User Name root admin Default Password dbps admin Adding Port Administrators and Users The system administrator and root user can add port administrators and additional users easily with the web interface by choosing System administration > User administration > Add user. Access Lists Multiple users can be defined within Access lists with access privileges or restrictions to the ports. See "Create an Access list" on page 70 for more infomation. Ways to Configure the Digi CM This section discusses the three ways to configure the Digi CM unit using the web interface, configuration menu, or command line interface. Chapter 1 15

16 Ways to Configure the Digi CM The Digi CM web interface features HTTPS for secure access. Web Interface The web interface provides an easy way to configure the Digi CM unit. The root user and system administrator can configure all features through the web. Port administrators can configure ports, including port clustering, but cannot modify system settings. No other users can use the web interface for configuration. There are two ways to access the web interface - the difference being whether or not the IP address is configured or if DHCP is running. ADDP (Advanced Device Discover Protocol) This device discovery tool allows you to find, configure and launch your web configuration and management interface. Find your device and double click it to access the web interface, or select your device and click Configure network settings (on the left navigation bar). Directly entering the IP address You can enter the IP address directly into the URL address bar of your browser. (Of course, the IP address must already be set up) Access the web interface from one of the previous methods. The following page is displayed after login. Configuration Menu The root user and system administrator have full access to the configuration menu from a Telnet or SSH session or a serial connection through the console port. Functionality is similar to the web interface, with the exception of custom menus, which can be created only from the web interface. The configuration menu is presented to system administrators automatically. Root users access the menu by entering the command configmenu. Port administrators can access this menu but can modify serial port configuration only. No other users 16 Chapter 1

17 Introduction can access this menu. Command Line Interface The command line interface can be accessed from a Telnet or SSH session or from the console port. The root user always has access to this interface. The system administrator can be granted read-only permission as well. No other users can access the command line interface. Ways of Accessing the Digi CM Ports: Overview There are five ways to access the ports on the Digi CM unit: Web Interface Port Access Menu Direct Port Access Custom Menus SNMP Web Interface Access Menu The web interface menu provides easy and convenient access to ports. All users can access the menu by entering the the Digi CM unit IP address or host name in a web browser s URL window. You will only be able to see the ports that you are allowed to access. To access a port from the web interface, do the following: 1. Access the web interface. 2. Click Serial port > Connection. Chapter 1 17

18 Web Interface Access Menu The P (Power) column allows you to control power of the attached devices, if a Remote Power Management unit is attached and you have appropriate rights. The M (Manage) column offers web based management for Windows Server 2003, Remote Power Management units or Rackable Systems Management Card. The # of User column shows how many users are actually connected to the port and the username of the read/write user. If you are conducting a special task through the console port, like BIOS upgrade and should not be interrupted, you can notify other users by entering a comment upon connect. This comment is shown here. 3. Select a port by clicking the icon in the C (Console) column. A Java applet or Telnet window opens with a login prompt. 18 Chapter 1

19 Introduction The web interface can also be configured to call a local Telnet or SSH application, see "Configuring Host Mode" on page 54. Port Access Menu The Port Access Menu provides access to ports. It is accessible to all users through the web interface, Telnet and SSH sessions, and remote modem access. The information that follows shows you how to access this menu. Access Type Web interface Telnet/SSH Command line Telnet/SSH Permissions Any user can use this method. Any user can use this method. Root Any user Procedure 1. Access the web interface 2. Choose Serial port > Connection > Port access menu connection 3. Log in 1. Telnet to the Digi CM unit specifying its IP address and port (7000 is the default socket port for both Telnet and SSH) Example: telnet Log in From the command line, issue the portaccessmenu command. Example: portaccessmenu TCP port 23/22 Example: telnet If user s shell is configured to "Port access menu", please refer to "Administering Users" on page 69. Chapter 1 19

20 Direct Port Access Here is a screenshot of the Port access menu. Direct Port Access You can connect directly to a properly configured port through a Telnet or SSH session. Configuration requirements include setting the Host Mode to Console Server Mode and the Protocol to either Telnet or SSH. Ports, by default are set to Console Server Mode and Telnet. Use the following information to make a Telnet or SSH connection to a port: Type Command Syntax Example: Connection to Port 3 Telnet SSH WEB telnet ip-address tcp-port where ip-address is the Digi CM unit s IP address and tcp-port is the Listening TCP port for a port ssh user-name@ ip-address tcp-port where user-name is a user s name, ip-address is the Digi CM unit s IP address and tcp-port is the Listening TCP port for a port ssh user-name: or ssh user-name: where ip-address is the Digi CM unit IP address or NDS name, port-number is the number of the serial port and port title is the name of the port as assigned in serial port, port title. telnet (7000 is the default socket port for both Telnet and SSH) ssh admin@ p 7003 (7000 is the default socket port for both Telnet and SSH) ssh sunadmin: ssh ciscoadmin: connect.asp?t=cisco.router.port3 (the port name is case sensitive) Note: The example assumes that the Listening TCP port is 7003, the default for port 3. Custom Menus Custom menus are created by either root or the system administrator to limit your access to specific ports. For more information, see "Making Custom Menus" on page Chapter 1

21 Introduction Port Escape Menu Port escape is the ability to escape from a port without disconnecting. Port escape is available in main sessions as well as sniff sessions. Every connection method accommodates port escape. You configure the escape sequence per port. Follow the procedure to configure the port escape sequence. 1. Serial Port > Configuration > Select the port number or All. 2. Host mode configuration > Port escape sequence - enter a letter for the Port escape sequence. The default is <ctrl> z. 3. Click Save to flash and continue with other configurations or click Save & apply for the changes to take effect. The port escape menu is automatically started if there is one active session to the port established and a second user tries to connect. To open a sniff session: 1. Click Serial port > Connection. 2. Select the port you want to access. 3. Log in with your user name and password. Chapter 1 21

22 Port Escape Menu 4. Enter the letter of the port escape sequence. The following table describes the fields and the operations for the port escape feature. You will only see the fields allowed for your permissions. Description of Fields Escape Sequence Ctrl+ m s Description of Action take over main session (read/write) enter as a slave session (read only) Occurrence only presented to users with read/ write access upon entering a session only presented to users with read/ write access upon entering a session b send break not functional for sniff users l show last 100 lines of log buffer must enable logging for this option d disconnect a sniff session only functional to admin a send message to port user(s) not available to sniff users r p reboot device using power-switch power device on/off only if power management is available on this port (show only on or off) only if power management is available on this port 22 Chapter 1

23 Introduction Escape Sequence Ctrl+ Description of Action Occurrence x close current connection to port closes the current connection Note: By entering the port escape sequence twice, it is directly transmitted (once) to the connected device. If the escape sequence is entered twice within 1/2 second, the menu will not opened. SNMP An SNMP MIB to configure the Digi CM unit is available to be downloaded from support.digi.com. Saving and Applying Changes In the web interface, you can save and apply configuration changes in two ways. With the one-step method, you choose Save & apply and changes are saved and applied (take effect) immediately. With the two-step method, you choose Save to flash, which immediately saves changes but the changes do not take effect until you choose Apply changes. The following topics describe how to do each of these operations. One Step: Save and Apply Changes To save and apply changes immediately, choose the Save & apply button. Two-Step: Save to Flash and then Apply Changes To save multiple changes but apply changes once, do the following: Choose the Save to flash button. When you finish changing the configuration, choose the Apply changes link, which is located on the left navigation menu (or the Save & apply button at the bottom of the page.) Automatic Device Recognition This feature allows the Digi CM unit to automatically detect and recognize attached devices. The Digi CM unit sends down a probe string, Enter, by default then analyzes the response. It then displays the detected OS, device and port number like: CISCO.Router.port3 Sun.nemo.port5 To enable Automatic Device Recognition: 1. Serial Port > Configuration > Select the port number or All. 2. Port title Automatic Detection - Enable Use detected port title - Enable Probe String - \x0d (means <Enter>) Device detection method - Active Detection initiation - periodically Detection delay - every 5 minutes Chapter 1 23

24 Locator Light 3. Click Save & apply. For more details about Automatic Device Recognition please refer to 5chapter 4, Configuring Ports. Port 3 shows a real world example of a detected device. Automatic Device Recognition also monitors each of the configured serial ports. This allows you to receive an or SNMP trap if there is a change in the expected response from the device connected to the serial port. If the device goes down or is disconnected for any reason, you are notified. For configuration of this alarm feature please refer to 5chapter 4, Configuring Ports. Locator Light The Digi CM 48-port unit has a locator light on the front panel labeled Find Me. All other Digi CM units flash the serial port lights to indicate where the device is found. If you access the web interface, log in to the Digi CM unit, and scroll down the page, you ll find additional links. Click Start device locating and a popup box will appear to confirm. Click okay and the Digi CM unit Find Me light will blink (other Digi CM models blink all LEDs). To turn off the locator light, click Stop device locating. 24 Chapter 1

25 Getting Started Chapter 2 Getting Started Introduction This chapter covers basic configuration topics. Included is information on assigning IP settings, enabling secure access with the web interface, accessing the unit through SSH, and adding or removing users. Note: Initial setup is described in the Quick Start Guide included with the product packaging. A copy of this document is also available online at Assigning IP Settings from the Console Port The following steps use the console port to assign IP settings. The default IP address is Connect the console port on the rear panel of the Digi CM unit to a serial port on a workstation using the Ethernet console cable and the appropriate console adapter packaged with the the Digi CM unit. The arrow in the following graphic points to the console port. console port 2. Configure a terminal emulation program, such as HyperTerminal, using the following settings: bps=9600 data bits=8 parity=none stop bits=1 flow control=none. 3. Establish a connection to the console port and press Enter to get a command prompt. 4. At the login prompt, log in as admin. The default password for admin is admin. The Configuration menu appears. 5. Enter the number for Network configuration. 6. Enter the number for IP configuration. 7. Enter the appropriate parameters for the IP settings. 8. Press ESC when done to return to the main configuration menu. CM 32 back panel shown Chapter 2 25

26 Assigning IP Settings from the Console Port 9. Enter the number to exit and apply changes. Changes are saved and applied immediately. There is no need to reboot. 26 Chapter 2

27 Getting Started Configuring for SSH Accessing the Digi CM unit's command line via SSH is enabled by default (TCP port 22). Options The Port Access Menu and individual ports can be configured for SSH. The the Digi CM unit supports Blowfish and 3DES encryption methods for SSH. Configuring the Port Access Menu for SSH 1. Access the web interface. 2. Log in as root, admin, or a member of the port administration group. The default password for root is dbps, and the default password for admin is admin. 3. Under Serial port > Configuration > Port access menu configuration. The Port access configuration menu appears. 4. Select SSH as the Port access menu protocol. Note: Login on port access requires logging in twice (once for access to the port and once for port access menu) when enabled. Disabled allows one log in directly to the port. Chapter 2 27

28 Configuring for SSH 5. Click Save & apply. Configuring a Port for SSH 1. Access the web interface. 2. Log in as root, admin, or a member of the port administration group. The default password for root is dbps, and the default password for admin is admin. 3. Under Serial port > Configuration. 4. Select All or one individual port you want to configure for SSH. 5. Click Host mode configuration. 6. Specify SSH as the Protocol as shown in the following screenshot. 7. Click Save & apply. 28 Chapter 2

29 Getting Started Adding, Editing, and Removing Users The root user and system administrator can add, remove, or edit users from the web interface. Procedure 1. Access the web interface. 2. Log in as root or admin. The default password for root is dbps, and the default password for admin is admin. 3. Under the System administration heading click Users administration. 4. Select Add, Edit, Remove or click the username to edit a user. Add: Assign a user name, user group, password, and shell. Edit: Change user group, password, or their shell Remove: Remove a user from the system 5. Click Save & apply. Note: The root and admin users cannot be removed from the system. For more information about configuring access rights for specific users see "Configuring User Access Control" on page 77. About Shell Options The shell program selection determines the interface you see when establishing a Telnet or SSH session or connecting via the console port with Chapter 2 29

30 Adding, Editing, and Removing Users the Digi CM unit. User Group Shell Program Options root system admin port admin user command line command line, configuration menu, port access menu, custom menus configuration menu, port access menu, custom menus port access menu, custom menus 30 Chapter 2

31 Installing and Configuring PC Cards Chapter 3 Introduction Installing and Configuring PC Cards This chapter includes information on adding and configuring PC cards for the Digi CM unit. PC card devices that can be added to the the Digi CM unit include a serial modem, compact-flash card, wireless LAN card, and a network LAN card. Compatible PC Cards All compact-flash cards work with the Digi CM unit, but not all serial modem, wireless LAN, or regular LAN cards do. To see a list of compatible cards that have been tested with the Digi CM unit, visit the Digi support site at Adding a Compact-flash Card A PC card slot is located on the front panel of the Digi CM unit. The arrow in the following graphic indicates the PC card slot. PC card slot Digi CM 32 shown To install and configure the compact-flash card on the Digi CM unit, do the following. 1. Insert the card into the PC card slot. 2. Access the web interface. 3. Under the PC card heading click Configuration. Chapter 3 31

32 Adding a Network Card Always select the Stop card service button and Save & apply before removing the PC card. 4. Click Configure the detected card. The following fields appear on the configuration page. ATA/IDE Fixed Disk Card configuration Total data size to be used - Enter the amount of memory you want to assign to the compact-flash card for configuration files. Delete all files in ATA/IDE Fixed Disk Card - Select the Delete button to clear the compact-flash card of all files. Format ATA/IDE Fixed Disk Card. - The options are EXT2 or FAT formats. Select the format option and then select the Format button. 5. Enter the appropriate parameters on the configuration page. 6. Click Save to flash or Save & apply. Adding a Network Card To install and configure a network card on the Digi CM unit, do the following. 1. Insert the card into the PC slot. 2. Access the web interface. 3. Under the PC card heading, click Configuration. 32 Chapter 3

33 Installing and Configuring PC Cards Note: The card is automatically discovered and a configuration menu is displayed. 4. Enter the appropriate parameters in the configuration menu. 5. Click Save & apply. Note: If DHCP is active the IP address will appear after the configuration is saved and applied. Adding a Wireless LAN Card To install and configure a wireless LAN card on the Digi CM unit, do the following. 1. Insert the card into the PC slot. 2. Access the web interface. 3. Under the PC card heading, click Configuration. Note: The card is automatically discovered and a configuration menu is displayed. 4. Click Configure the detected card. 5. Enter the appropriate parameters in the configuration menu. WEP is the acronym for Wired Equivalent Privacy and is a security protocol Chapter 3 33

34 Adding a Serial Modem for wireless LANs using encryption to protect data transfers. If you are unsure of the settings for the wireless card, see your network administrator. SSID - Set Service Identifier and is the name of the wireless LAN network Use WEP key - Enable or disable the WEP key WEP mode - Encrypted or unencrypted WEP key length - The options are 40 or 128 bits if the WEP key is enabled WEP key string - Refer to the wireless network administrator for the wireless encryption key string 6. Click Save to flash. Adding a Serial Modem The modem must first be inserted and installed on your system before it can be used. To configure the modem do the following: 1. Access the web interface. 2. From the menu click Configuration under the PC card heading. Note: The card is automatically discovered and a configuration menu is displayed. 34 Chapter 3

35 Installing and Configuring PC Cards 3. Click Configure the detected card. 4. Edit any appropriate parameters and Click Save & apply. Chapter 3 35

36

37 System Status and Port Logging Chapter 4 System Status and Port Logging Introduction The Digi CM unit provides four options for saving system and port logs: A syslog server An NFS server A compact-flash card The Digi CM unit s memory When memory is selected as the storage location, log files are saved to volatile memory, meaning files are lost when the power is turned off. To use a syslog server, an NFS server, or a compact-flash card, you must first enable the devices and enter the required information. Compact-flash cards must be installed before they can be enabled and configured for logging purposes. System logs track events such as logins, authentication failures, system configuration changes, and more. Port logs, on the other hand, document the data flow through the serial ports. This chapter outlines locations for viewing the system and port logs. System Status & Log For basic system information Click System status & log. The parameters for the system status are described in the following list. System Information Model No. - Identification of Digi device Serial No. - Serial number of product F/W Rev. - Revision number of firmware B/L Ver. - Bootloader version MAC address - MAC address of Digi device Uptime - Amount of time since last reboot Current time - : Time based on time set for Digi device System logging - :Status of system logging either Enabled or Disabled Send system log by - Condition for notification: PC card type - :Description of PC card if configured PC card model - :Model of PC card if configured Power status - :Dual power ( 1 - Normal, 2 - Normal ) Chapter 4 37

38 Enabling Log Storage Location IP Information Enabling Log Storage Location IP mode - Method for setting IP address either Static, DHCP, PPPoE, or Disable IP expiration - When the IP address will expire IP address - Actual IP address Subnet mask - Address of the Subnet mask Gateway - Address of the Gateway Receive/Transmit errors - Number of errors from receiving or transmitting Primary DNS - IP address of the primary DNS Secondary DNS - IP address of the secondary DNS Enable NFS Server You can save log data to an NFS server, but the NFS server must be configured with read and write privileges. To use an NFS server, you must specify the NFS server s IP address and its mounting path. Encrypted NFS is using a SSH connection to tunnel all data. To enable the NFS server for port or system logging, do the following: 1. Access the web interface. 2. Under the Network heading, Click NFS server configuration. NFS service - Enabled or disabled. Primary NFS server name -IP address of NFS server or DNS name Mounting path on primary NFS server - Directory to primary NFS server Primary NFS timeout - Interval in seconds before timeout (5-3600) Primary NFS mount retrying interval - Interval in second between attempts to connect (5-3600) Enable/Disable encrypted primary NFS server - If server supports encrypted NFS server Encrypted primary NFS server user - User name of server Encrypted primary NFS server password - Password Secondary NFS service - Enabled or Disabled Secondary NFS server name - Name of server Mounting path on secondary NFS server - Directory to server Secondary NFS timeout (sec, ) - Timeout in seconds Secondary NFS mount retrying interval (sec, ) - Retry interval in seconds Enable/Disable encrypted secondary NFS server - If secondary server supports encrypted NFS server Encrypted secondary NFS server user - User name Encrypted secondary NFS server password - Password Confirm secondary NFS server password - Repeat password 38 Chapter 4

39 System Status and Port Logging 3. Choose Enabled. 4. Enter the IP address of the primary and secondary (if applicable) NFS server and the mounting path of each. 5. Click Save & apply. Alert for NFS Server Disconnect You can also set up an alert and/or an SNMP trap configuration for an NFS server disconnect. To configure this feature, use this procedure. 1. Farther down the NFS Configuration screen, at the alert configuration, select Enable. 2. Enter the Title of and the Recipient's address. 3. For an SNMP trap configuration select Enable NFS disconnection trap 4. Select Enable for Use global SNMP configuration, and enter the IP information for Trap receiver settings. 5. Click Save & apply. Chapter 4 39

40 Enabling Log Storage Location Enable SYSLOG Server To enable the Digi CM unit for system or port logging on a syslog server: 1. Access the web interface. 2. Under the Network heading, click SYSLOG server configuration. 3. Choose Enable. 4. Enter the IP address of the primary and secondary (if applicable) syslog server, and select the syslog facility from the drop down menu. 5. Click Save & apply. Enable a Compact-flash Card The compact-flash card must be installed and configured on the Digi CM unit before it can be used for system logging or storing the Digi CM unit s configuration information. When storing log files to an external flash card, the size of the available storage is dependent on both the size of the card and the port counts of the Digi CM unit used. The maximum settings for log file sizes are listed in the following table. See also Adding a Compact-flash Card on page 31. Total Flash Card Size Digi CM System Log Port Log (per port) Total Memory Used M M K K 29M 40 Chapter 4

41 System Status and Port Logging Total Flash Card Size Digi CM System Log Port Log (per port) Total Memory Used M M M M M M M M M M M M 58M 118M 236M Enable the Digi CM Unit s Memory The Digi CM unit s memory is already enabled for port logging and needs to be configured only for system or port logging. When storing log files to the Digi CM unit s local memory, a total of 3.5M is available. The amount of memory per serial port is dependent on the port count of the Digi CM unit used. The log file sizes shown in the following table are maximum settings. See also Configuring System Logging on page 41. Digi CM System Log Port Log (per port) Total Memory Used 8 400K K 300K K 3.5M 48 66K Configuring System Logging To configure the Digi CM unit for system logging, do the following: 1. Access the web interface. 2. Under System status & log, click System logging. 3. Choose Enabled for System logging and the log buffer size. Chapter 4 41

42 Configuring System Logging 4. From the System log storage location, choose the location from the drop down menu. The choices are dependent on what you have enabled and/or installed. The Digi CM unit s memory choice is always available. System logging - Enable or Disable System log storage location - Memory or NFS server System log to SYSLOG server - Enable to store system logs to a SYSLOG server System log buffer size (KB, 300 max) - Log buffer size in KB Automatic backup on mounting This parameter defines the action taken if a NGFS partition of a CF card or NFS server is mounted or re-mounted. Enable: rename the existing log file by adding a -xx with xx being a incrmented number. Disable: keep writing to the existing log file. Send system log by -Number of log messages to send a mail (1-100) - Number of messages System log recipient s mail address - address for log recipient 5. Choose to enable or disable alerts and the number of log messages to send. The default value is 5 seconds for the delay in log messages. 42 Chapter 4

43 System Status and Port Logging 6. Enter the contact address. 7. Click Save & apply. Viewing System Logs The system logs can be viewed from the web interface on the System logging page or from the location where they have been saved. The following table lists the file locations of the system logs. System Logfile Log Storage Digi memory Compact-flash card Syslog server NFS server File Location /tmp/logs /mnt/flash/logs must be viewed on the syslog server /mnt/nfs/logs Configure Port Logging If a serial port is configured for console server mode, the port logging feature can be enabled. Port logging allows you to save serial data to the memory of the Digi CM unit, a compact-flash card, a syslog server, or to an NFS server. If the memory is used for port logging, all data is cleared when the system s power is turned off. You can also define alarm keywords for each serial port and send alerts or SNMP traps to enable unattended serial data monitoring. The following steps configure a serial port for port logging in console server mode. 1. Access the web interface. 2. Under the Serial port heading, click Configuration. 3. Choose All or the Individual port, and then Port logging. 4. Configure the settings: Logging direction - Specify what to log: Server only server output, User only user output, Both with/without arrows server and user output with/without directional arrows. Default: server output. Security advice: When logging user output passwords will be saved into the log file! Port log to SYSLOG server - Enable to store port logs to a SYSLOG server Port logging filename - Options are to specify your own or use the port title for the port log filename Chapter 4 43

44 Configure Port Logging Show last 10 lines of a log upon connect -Show previous last 10 lines of log when connecting to this port Strip the ^M from SYSLOG -For logging to a SYSLOG server, strip out all ^M Automatic backup on mounting This parameter defines the action taken if a NGFS partition of a CF card is mounted or re-mounted. Enable: rename the existing log file by adding a -xx with xx being a incrmented number. Disable: keep writing to the existing log file. Monitoring interval -The frequency in seconds to update the port log 5. Click Save & apply. Note: When port logging is enabled, a Port Event Handling page is available to create alarm keywords and send alerts. See Chapter Alerts and Notifications on page 61 for more information. Viewing Port Logs The port logs can be viewed from the web interface on the Port logging page or from the location where they have been saved. The following table lists the file locations of the system logs. 44 Chapter 4

45 System Status and Port Logging Port Logfile Log Storage Digi memory Compact-flash card Syslog server NFS server File Location /tmp/port#data /mnt/flash/port#data must be viewed from the syslog server /mnt/nfs/port#data To view the port logs on the NFS server for port number 5, enter the following command: more /mnt/nfs/port5data Partial logfiles can also be viewed on the web interface by going to Serial port > Configuration > select a port you want to view > Port logging. Chapter 4 45

46

47 Configuring Ports Chapter 5 Introduction Configuring Ports This chapter provides information on configuring serial ports. Key port configuration attributes include whether or not the port is enabled or disabled, the host mode, which defines a type of communication between the port and a remote host, the protocol, authentication, user access restrictions, and serial communication attributes. It also covers remote port support. Enabling and Disabling the Ports All serial ports may be enabled or disabled individually or as a group from the web interface. 1. Click Serial port > Configuration > Port number or all 2. Select Enable or Disable from the drop down menu. 3. Click Save to flash and continue with other configurations or click Save & apply. RealPort Support RealPort software provides a virtual connection to serial devices, no matter where they reside on the network. The software is installed directly on the host Chapter 5 47

48 RealPort Support and allows applications to talk to devices across a network as though the devices were directly attached to the host. In actuality, the devices are connected to a Digi device server or terminal server somewhere on the network. RealPort is unique among COM port re-directors because it is the only implementation that allows multiple connections to multiple ports over a single TCP/IP connection. Other implementations require a separate TCP/IP connection for each serial port. Unique features also include full hardware and software flow control, as well as tunable latency and throughput. When you use RealPort (configured on a per port basis) the Digi CM unit functionality is unavailable. That is to say that the Digi CM unit can be used for console management or for COM re-direction but not both. An example of RealPort use would be remote kernal debugging of Microsoft Windows Servers. To enable RealPort use the following procedure. Note: RealPort does not support authentication and user rights are not validated. 1. To enable RealPort click Serial port > Configuration > Port number. 2. Select Enable this port from the drop down menu. 3. Select Enable RealPort support from the drop down menu. 4. Click Save to flash and continue with other configurations or click Save & apply. 48 Chapter 5

49 Configuring Ports Resetting Ports The Digi CM unit allows you to restart all processes associated with a port and to disconnect all sessions. To reset an individual port: 1. Click Serial port > Configuration > Port number. 2. Click Reset this port: Reset. Reset Individual Port Settings Individual ports can be reverted to factory defaults. 1. Click Serial port > Configuration > Port number. 2. Click Set this port as factory default: Set. Port Title The Digi CM unit offers multiple ways to configure the port title; both manually and automatically. The default is set to Port Title # xx with xx being the portnumber. Automatic Device Recognition allows the Digi CM unit to evaluate the attached devices and populate the port title. Additionally the Digi CM unit can generate a SNMP trap or send an in case the response of the device changes or it stops responding. If Active detect is selected, a configurable probe string (carriage return =0x0d by default) is sent to the console port and the response is saved to a file at /var/run/systemrep_raw.portxx with xx being the port number. This file is parsed using a script /tmp/cnf/active_detect and the operating system and device name are written to files: /var/run/hostnameportxx and /var/run/osportxx. The commands to parse the system response are user customizable, so if a device is not recognized immediately by the Digi CM unit, add a rule to the file. If Passive detect is selected, no probe string is sent to the attached device but the port buffer is analyzed. The script /tmp/cnf/passive_detect is executed and the results are saved to files: /var/run/hostnameportxx and /var/run/osportxx. After editing the scripts as either active_detect or passive_detect, save them to flash using the saveconf command so they are not lost after a reboot. Configuring Automatic Device Recognition Configure a serial port for Automatic Device Recognition. 1. Access the web interface. 2. Under the Serial Port heading, Click Configuration. 3. Choose All or an Individual port > Serial port parameters. 4. Edit the fields as they apply to your configuration. Chapter 5 49

50 Configuring Automatic Device Recognition Automatic detection - Enable or disable automatic detection of devices Use detected port title - Enable if you want the Digi CM unit to automatically use the results of the detection mechanism to populate the port title. Disable if you want the default port title. If you choose Disable, you can still use the alarm feature. Port title - Manually entered or automatically populated title of the port. The Digi CM unit allows access to a port by using only the number of the port title, making it unnecessary to know the serial port number. The default is set to Port Title xx with xx being the port number. Probe string - The probe string is an ASCII string that is sent to the device. Special characters are coded in hexadecimal values like: CR \x0d LF \x0a ESC \x1b Examples are: Parse string root\x0d\x0a \x1btest\x0d \x1b test\x0d output root<cr><lf> <ESC>test<CR> <ESC><Space>test<CR> 50 Chapter 5

51 Configuring Ports \x1b\x20test\x0d <ESC><Space>test<CR> \x1b\x20\x74\x65\x73\x74\x0d <ESC><Space>test<CR> Detected OS - Displays the result of the Active or Passive detection process. Device detection method - If Active is selected a probe string is periodically sent to the device and the response is analyzed. If Passive is selected, the port logging is parsed to determine the device name and the OS. Detection initiation - Active only if automatic detection is Enabled. Periodically or If new device is detected are the choices in the drop down menu. If Periodically is selected, the probe string is sent once every n minutes to the device while no connection is active to the serial port. When If new device is detected is selected, the probe string is only sent if a change on the DSR signal on the serial port is detected. Normally a device will activate the DSR signal if the serial port becomes active. Detection delay - The delay before the first active detect process is started and between active detections. 5. Click Save & apply. Apply all Ports Settings The Digi CM unit supports managing all ports simultaneously. If changes are made to the page all ports, they are automatically applied to all ports. You can choose to exclude ports from this feature. To enable/disable this feature for a port: 1. Access the web interface. 2. Under the Serial Port heading, click Configuration. 3. Choose an individual port > Host mode configuration. 4. Select Enable or Disable from the drop down menu. 5. Click Save to flash and continue with other configurations or click Save & apply. Note: When changing a parameter for all ports, all settings of the complete page are applied to all ports.. Chapter 5 51

52 Host Mode Configuration Host Mode Configuration The Digi CM unit provides four modes of communication between serial devices and remote hosts. Console server, terminal server, dial-in modem, and dial-in terminal server. These are described in the following sections. Console Server Mode Configuring a serial port as a console server creates a TCP socket on the Digi CM unit that listens for a Telnet or SSH client connection. When you connect to the TCP socket, you have access to the device attached to the serial port as though the device were connected directly to the network. RawTCP is also supported with the Console Server Mode. serial Connection request 52 Chapter 5

53 Configuring Ports Terminal Server Mode In terminal server mode, the Digi CM unit s serial port is configured to wait for data from the device connected to the port. If data is detected, the Digi CM unit starts a TCP session as a Telnet or SSH client to a pre-defined server. The server must be defined by you before the port can be configured for a Telnet or SSH client. This mode is used when you want to access servers on the network from a serial terminal. RawTCP is also supported with the Terminal Server Mode. Connection request terminals serial Dial-In Modem Mode In this mode, the Digi CM unit assumes an external modem is attached to the serial port and is waiting for a dial-in connection from a remote site. When a user dials-in using a terminal application, the Digi CM unit accepts the connection and displays the appropriate prompt or menu for you that logged in. Example: User root would see the command line interface (CLI), whereas the user admin would see the config menu or CLI depending on the shell for that user. Chapter 5 53

54 Configuring Host Mode Dial-In Terminal Server Dial-in terminal server mode is a combination of the terminal server mode and the dial-in modem mode. In the dial-in terminal server mode, the Digi CM unit assumes the serial port is connected to an external modem and is waiting for a dial-in connection from a remote site. When you dial-in using terminal applications, the Digi CM unit accepts the connection as a Telnet or SSH client to a pre-defined server. This mode is most frequently used when you want to use modems to access servers on a network. Configuring Host Mode To configure a serial port for host mode, enter the values in the applicable fields. To access the Host mode configuration screen, do the following: 1. Access the web interface. 2. Under the Serial Port heading, click Configuration. 3. Choose All or an Individual port > Host mode configuration. 4. Fill in the highlighted fields as they apply to your configuration. Host mode - The options are console server mode, terminal server mode, dial-in modem mode, and dial-in terminal server mode. Type of console server - The options are MS SAC console -English or Japanese which you use to provide a graphic user interface to the Windows Server 2003 Special Administration Console (see "Microsoft SAC Support" on page 95) and Other, which you use in all other cases. Rackable Systems Mgmt Card - Enable to use Rackable s Management card. Enable/Disable assigned IP - Determines whether an IP address will be assigned to the port. The default is Disabled. Assigned IP - Also known as alternate IP, this field assigns an IP address to the port, enabling you to Telnet directly to the serial port using an IP address (without having to specify a TCP port). 54 Chapter 5

55 Configuring Ports Listening TCP port - This is the TCP port you will specify when connecting directly to the port using Telnet or SSH. Protocol - The options are SSH, RawTCP, and Telnet. Inactivity timeout - In seconds, the time set for inactivity to trigger an action. Setting the timeout to 0 (zero) means no timeout. Enable/Disable port escape sequence - Allows the port escape sequence to function. Port escape sequence - The key combination to initiate port escape. Port break sequence - The sequence of characters that sends a break character to a device. Use comment - Determines whether a port user is prompted to add a comment each time the port is accessed. Quick connect via - Determines method for connecting to a port when in console server mode. Available with Telnet/SSH. Web applet encoding - Supported languages for Java terminal. 5. Click Save & apply. Chapter 5 55

56 Supported Protocols Supported Protocols. In configuring a serial port, you have three protocol options. The three protocols available are: RawTCP, SSH, and Telnet. Choose SSH as the the Digi CM unit supports three protocol when logging in from an SSH client program to access a port. Choose protocol options: SSH, Raw TCP, and RawTCP when connecting directly to a TCP socket. Choose Telnet when Telnet. logging in from a Telnet client program and accessing the ports. Use the Host mode configuration page in the web interface to select the correct protocol. Serial Port Parameters In attaching a serial device to the Digi CM unit s serial port, the port parameters must match. The serial ports by default are enabled, meaning you have full access to the port. To configure the port parameters for the Digi CM unit, do the following: 1. Access the web interface. 2. Under the Serial Port heading, Click Configuration. 3. Choose All or an Individual port > Serial port parameters. 4. Fill in the serial port parameters. The following are the defaults: bps=9600, data bits=8, parity=none, stop bits=1, flow control=none, and DTR behavior=high when open. 5. Click Save & apply DTR Behavior DTR can be set on the serial port to one of three settings: always high, always low, or High when open. Setting the DTR to High when open keeps the DTR high if a TCP connection is established. The DTR setting cannot be set by you when the host mode is configured for dial-in modem or dial-in terminal server mode. Inter-character Timeout This setting is only available when the host mode protocol is set for RawTCP. The parameter sets the time value for the Digi CM unit to transfer data stored 56 Chapter 5

57 Configuring Ports in the buffer. The Digi CM unit transfers data when the buffer is full using the TCP/IP protocol. However, if it is not full, the Digi CM unit will also transfer data dependent on the timeout value selected. Specialty Use of Port -When Data is Processed in Chunks Some applications are written to process only chunks of data rather than continuous streams of data. The Digi CM unit supports chunking holding back data from the serial device to the application on the network until it detects a delimiter - at which point it sends the data to the application. To configure a port for this mode: 1. Open a web connection to the Digi CM unit. 2. Click Serial Port > Configuration. 3. Select All ports to configure. 4. Click Host Mode configuration. 5. Under Protocol, select RawTCP. 6) Select Serial port parameters 7) Configure the delimiter and supporting settings. Descriptions of the options follow. Chapter 5 57

58 Remote Ports Enable/Disable delimiter --Allows deliminator to function. Delimiter - Define the sequence that should be received before forwarding the data to the application Delimiter option - with delimiters - sends the delimiter as part of the data to the application without delimiters - remove the delimiter before sending the data to the application Inter character time-out timeout - In msec ( ) If no delimiter is detected the data is delivered after this timeout has elapsed. Remote Ports The Digi CM unit supports remote ports. Remote ports are any type of port that can be accessed using Telnet or SSH protocol. Types of ports include ports that are provided using PortServer Terminals Servers or Sun ILOM ports. This feature establishes the Digi CM unit as the central access system for any kind of text based out-of-band management. Using the Digi CM unit as a central access system has multiple advantages: Central point of access Central user authentication Capturing of every user transaction on the remote system Keyword monitoring and alarm while connection is up. Configure Remote Ports To configure a remote port use the following procedure. 1. Access the Digi CM unit s web interface 2. Under the Serial Port heading click Configuration. 3. Scroll down the page to the section called Remote port configuration. 4. Enter the port title and click Add. A pop-up window will appear to confirm the action. 5. Click the port title to access the configuration menus. 6. Select Remote port parameters 7. Enter the IP address, port number, and protocol to use. 8. Confirm you selections by clicking Save &apply. A pop-up window will appear to confirm the successful execution. Note: If you want to use a Digi PortServer TS 2 as remote device you would configure: IP address as assigned, IP port 2001 for port 1 or 2002 for port 2 and telnet or 2501/ 2502 when using SSH as protocol. All other settings of the remote port are equivalent to the settings of a local serial port. Accessing a remote port You can connect to a remote port using the web, Telnet or SSH client. You can 58 Chapter 5

59 Configuring Ports Also use the port access menu or a custom menu to simplify navigation Web Access Click Serial ports > Connection > Port number. Remote ports are sorted below the physical serial ports as V1... Telnet Telnet to the IP and the port number (the specific port number is defined on the Host mode configuration page. telnet SSH to the port number SSH to the IP and the port number (the specific port number is defined on the Host mode configuration page). SSH to the port name SSH to the IP and the port number (the specific port number is defined on the Host mode configuration page). Ssh user-name: Ssh sunadmin: t=switch3level :@MainDigi You can access a remote port just like any local port: - directly using the portnumber Note: The parameters of the remote port are equivalent to regular serial ports. Enter any additional parameters for the remote and click Save & apply or Apply all changes. Chapter 5 59

60

61 Alerts and Notifications Chapter 6 Introduction Alerts and Notifications The Digi CM unit can be configured for system alerts and notifications. It sends messages when the number of system log messages reaches a certain value or when an alarm message is detected in the serial port data. The Digi CM unit uses SMTP (Simple Mail Transfer Protocol) for sending the notifications. To use SMTP, the system administrator must configure a valid SMTP server for sending the s. The Digi CM unit supports three types of SMTP servers: SMTP server without authentication, SMTP server with authentication, and POP before SMTP. The Digi CM unit also supports SNMP (Simple Network Management Protocol), a protocol used to manage a network and monitor devices on a network. System and port alerts can also be sent using SNMP traps. The Digi CM unit supports both versions 1 and 2 of the SNMP protocol. The main function of SNMP on the Digi CM unit is to allow a system administrator to query remote devices for information. PANIC serial PANIC Chapter 6 61

62 Configuring SMTP Alerts Configuring SMTP Alerts Most SMTP servers check the sender s address with the host domain name to verify the address as authentic. Consequently, when assigning an address for the device address, any arbitrary username with the registered hostname may be used. An example is username@company.com. To configure the Digi CM unit for SMTP alerts, the following parameters are required: SMTP server - Use either the hostname or the IP address. Device mail address - Specify the sender s address for the log and alarm delivery. SMTP mode - Specify the type of SMTP server to use. Username and password - These fields are required for POP before SMTP and SMTP with authentication servers. To configure SMTP alerts on the Digi CM unit, do the following: 1. Access the web interface. 2. Under the Network heading, choose SMTP configuration. 3. Fill in the required fields. SMTP with authentication and POP before SMTP require usernames and passwords. 4. Click Save & apply. SNMP Information Applications such as NMS (Network Management System) or an SNMP The Digi CM unit supports SNMP authentication, power on, and link up traps. browser can exchange information with the Digi CM unit and control actions to the unit. The protocol functions defined for SNMP includes GET, SET, GET- Next, GET-Bulk, and TRAP. Below are the definitions of the protocol functions found in SNMP. Authentication, power on, and link up traps are supported.. Protocol GET SET GET-Next GET-Bulk Function Queries a device for more information Makes changes to a device s state After an initial GET query, goes to the next value Retrieves tables of information and security functions 62 Chapter 6

63 Alerts and Notifications Protocol TRAP Function Notifies a system administrator of a significant event Traps There are additional traps that can be set at the port level. The following table shows where the trap is under Serial port > Configuration on the web interface, trap name, configure options, and the trap functions. The MIBs for login traps can be found at Trap Location Trap Name Function Port access menu Alert configuration Alert configuration Alert configuration Alert configuration Port event handling Port login trap Port login trap Device connection trap Active detection trap Dial-in modem test trap Keyword notification trap Notify about any login action to the port access menu (succeed and fail) Notify about login to this specific port (succeed and fail) (only available if host mode is set to "Console server") Notify about a change of the DTR signal line (only available if host mode is set to "Console server") Notify about changes in the device's response to the probe string (see also "Automatic Device Recognition" on page 23, only available if host mode is set to "Console server") Notify about modem test (succeed and fail) (only available if host mode is set to "Dial-in modem") Notify about the occurrence of a keyword in the port log (only available if host mode is set to "Console server") Configuring SNMP To configure the Digi CM unit for SNMP do the following: 1. Access the Digi CM unit s web interface. 2. Under the Network heading, choose SNMP configuration. 3. Fill in information for the MIB-II system objects section and choose Yes under EnableAuthenTrap. The fields are described in the following section: syscontact - Identity of the contact person managing the MIB-II system. sysname - The name identifying the system. By convention, this is the fully qualified domain name of the Digi CM unit. An example is: DigiCM@companyname.com. syslocation. - The physical location of the unit such as Room 264 or Engineering Lab. sysservice (Read only). - A series of values, separated by commas, indicating the set of services the system provides. By default, the Digi CM unit only supports Application (7) service level. EnablePowerOnTrap. - Determines whether the SNMP agent generates a trap each time the Digi CM unit is started. EnableAuthenTrap. - Indicates whether the SNMP agent process is permitted to generate authentication failure traps. Chapter 6 63

64 Managing the SNMP Protocol EnableLinkUpTrap. - Determines whether the SNMP agent generates a trap each time the network connection comes up. EnableLoginTrap - Determines whether the SNMP agent generates a trap for each login. Note: Trap values override all other configuration information, meaning all other authentication failure traps can be disabled with this setting. 4. Enter Access control settings based on the following field descriptions: IP Address - Defines what applications can access the Digi CM unit s SNMP agent to exchange information and control actions. If no IP addresses are listed, any application can access the SNMP agent. Community - The options are public or private. Permissions - The options are Read only or Read/Write. 5. Enter Trap receiver settings based on the following field descriptions: IP Address - Enter the IP address of the device receiving the trap alerts. Community - The options are public or private. Version - Choose the SNMP version, either version 1 or version 2c. 6. Click Save & apply. Managing the SNMP Protocol The Digi CM unit s SNMP protocol can be managed using an NMS or SNMP browser. However, before the NMS or SNMP browser can access the data, the Access control settings must list the IP address of the host from which the browser is executed. See the preceding graphic for details. 64 Chapter 6

65 Alerts and Notifications Configuring Port Event Handling Once an SMTP or SNMP server has been configured, it can be used to send port-related alerts and notifications. The following describes how to configure a port for port event handling. 1. Access the web interface. 2. Choose Serial port > Configuration. 3. Choose a port to configure and then Port logging. 4. Select Enable. 5. Choose Save & apply. 6. Choose Port event handling. The following page appears. Chapter 6 65

66 Configuring Port Event Handling 7. Select an action and enter the keyword for the port event handling. 8. Enable notification. Note: It is assumed that SMTP is configured first. If not, see "Configuring SMTP Alerts" on page Enter the title of the (subject line). 10. Enable or Disable Case sensitive. 11. Enter the recipient s address. 12. Enable SNMP trap notification. 13.Enter the title of the trap. 14.Choose either to use the global SNMP settings by enabling "Use global SNMP configuration" or specify special settings for this port. 15.Enter the IP address of the trap receiver. 16. Enter the SNMP community 17. Select the version. 18. Complete configuration and then choose Save & apply. Note: Key word is any text string that will trigger an alert when it traverses the serial port. 66 Chapter 6

67 Alerts and Notifications Config Alerts for Automatic Device Recognition (ADR) Before configuring the alerts for Automatic Device Recognition, be sure you have configured the port for ADR as described in "Configuring Automatic Device Recognition" on page Access the web interface. 2. Under the Serial Port heading, Click Configuration. 3. Choose All or an Individual port > Alert Configuration. 4. Follow the Alert steps to configure the alert or follow the SMTP Notification to configure SMTP. Alert Enable " Alert for active detection" Enter the Title of Enter Name and address where the should be sent. SMTP Notification Enable "Active detection trap" Configure the trap receiver by one of the following two ways: Enter "Use global SNMP configuration" OR Enter the IP address of the trap receiver, the SNMP trap community and select the version 5. Complete configuration and choose Save & apply. Chapter 6 67

68 Config Alerts for Automatic Device Recognition (ADR) 68 Chapter 6

69 User Administration Chapter 7 User Administration Administering Users Required Privileges Only root and admin can administer users. The root user has unlimited administration privileges. Admin can view and change all attributes except those that belong to the root user. There are several ways to manage users. A user can be added, edited, or removed. Multiple users can be managed in Groups or Access lists. The difference between Groups and Access lists are that Groups are established in the operating system on the Digi CM unit and privileges are predefined such as Root or Admin and are used most often for configuration. Access lists allow access to the ports and are created by defining the privileges of the lists. Access Lists manage rights of multiple users at the same time. Multiple users with the same rights are associated with an access list. This allows the administrator to simplify the overall administrative process. Procedure 1. Access the web interface. 2. Under System administration, choose Users administration. The following screen appears. Note: The username on the Digi CM unit is case sensitive. 3. Do one of the following: To... Add a user Do the Following Click Add. 2. Fill in the attribute fields. See the table that follows for information on attribute fields. 3. Click Add. Chapter 7 69

70 Administering Users To... Edit a user Remove a user Create an Access list Do the Following Click on the username. 2. Fill in the attribute fields. See the table that follows for information on attribute fields. 3. Click Submit. 1. Check the box that corresponds to the user you want to remove. 2. Click Remove. 3. Choose OK at the prompt. 1. Under System administration, click Access List. 2. Enter the name of the Access List and click Add. 3. Click on the access list name to add users 4. Add the users to the access list Note: The name field in the Access list allows you to add users that are not locally configured on the Digi CM unit but use a centralized authentication method like RADIUS, LDAP etc.. To change the privileges of an Access list, see "Change the Privileges of an Access List" on page Click Apply changes. To Add an Access List to the Digi CM Unit 1. Access the web interface of the Digi CM unit. 2. Under System Configuration choose Access Lists 3. Enter the access list name into the edit-box and click [ADD]. A pop-up windows will appear confirming the successful addition of an access list. Now you can add users to the access list by: 1. Click the name of the access list; a configuration windows will open 2. Add one user at a time to the list by: Entering the name into the edit-box and clicking on [ADD]. Note: Caution! Spelling is not verified against the local user database. This allows you to add externally configured users that only exist in the RADISU, LDAP or other central databases. 70 Chapter 7

71 User Administration After an access list has been added to the system, port rights can be associated with it. See chapter 8. User Fields Field User name Select group Password Confirm password Shell program SSH public key authentication SSH public key to use Select new SSH public key version Select new SSH public key file Description Name for the user, which must be between 3 and 29 characters and cannot include colons (:), less than or greater than signs (< >), ampersand (&), spaces, or quotation marks. The at and period. are acceptable. The username on the Digi CM unit is case sensitive. Group to which the user is assigned. Groups include Root, System Admin, Port Admin and User. See "User Groups" on page 15 for more information Password to assign to the user. This must conform to the rules stipulated above for a user name. Confirms the password. Interface presented to the user when he/she logs on to the system from a Telnet or SSH connection. Alternative method of identifying yourself to a login server. More secure than just a password. Current public file key or create a new public file key SSH1 only supports one type of key SSH2 supports both RSA and DSA key types Location for the SSH public key file Chapter 7 71

72

73 Configuring Security and Authentication Chapter 8 f Configuring Security and Authentication Introduction The Digi CM unit provides four methods for controlling access to the network and the devices on the network: Restricting or permitting IP filtering This method allows or prevents users with specific IP addresses from accessing devices or serial ports on the network. IP filtering can be permitted or restricted for all ports globally or per port. Restricting or permitting specific users You easily can add users to or remove them from a list of restricted or permitted users list. Enabling sniff session access This method allows multiple users to access a single port. Using a central point (System administration > Security profile) where you establish security parameters per network, port, or password. The Digi CM unit supports several authentication methods, including: Local RADIUS TACACS+ LDAP Kerberos (The Kerberos module is not part of the normal firmware because of memory constraints. You can download the module from and place onto /usr2/ if required. To copy files to /usr2/, use a scp tool such as WinSCP.) Custom PAM. You can configure authentication so that a secondary method is attempted if the primary method fails. Configuring Network IP Filtering The Digi CM unit offers built-in firewall functionality to limit TCP/IP traffic to and from certain networks, TCP ports, and interfaces. The functionality implemented is based on the Linux tool IP tables. Chapter 8 73

74 Configuring Network IP Filtering The next scenario shows that access to the device connected to the Digi CM is allowed only on the.1 subnet. The device at can access the device connected to the Digi CM because it is in the range allowed by the IP Filter rule. Filter IP: Filter Mask: serial It is also possible to enable or disable specific services of the Digi CM unit by creating IP Filtering rules: Telnet console (TCP/IP port 23) SSH console (TCP/IP port 22) Web configuration (TCP/IP port 80) The fields are described next: Interface -The name of the network interface through which a packet is received. The name can be one of these values: eth0: the default Ethernet interface of the Digi CM unit eth1: the secondary interface added by using a PC card or wireless card all: both interfaces 74 Chapter 8

75 Configuring Security and Authentication Option - Determines that the rule will be applied to the IP address/mask specified or its inverse; that is, the rule will be applied to all except those specified. Normal: applied to the hosts that are included Invert: applied to the hosts that are excluded IP address/mask - Specifies the host range by entering base host IP address followed by / and subnet mask. The host range can be one of the following scenarios by changing the value: Only one host of a specific IP address Hosts on a specific subnet Any host Specified host range Input format Any host / / ~ / ~ / ~ / ~ / Protocol - - The protocol that is being accepted on or dropped from the port: TCP UDP ICMP Port - - A TCP/IP port on the Digi CM unit that other hosts try to access. You can specify either one port, using a single value, or a range of ports in this form : port1:port2 where port1 defines the lowest port and port2 the highest port. Chain rule - Determines whether access from the hosts is allowed: ACCEPT: Access allowed DROP: Access not allowed To add a new IP filtering rule, enter the values for the parameters and click the Add button on the right side of the table. To remove a rule, click the Remove button. After you finish editing the table, save the settings to flash: To save your changes, use the Save to flash button. To save and apply your changes, use the Save & apply button. Chapter 8 75

76 Configuring Network IP Filtering Be aware that you must apply the changes to make them active. This screen shows five established IP rules. This table describes the rules. Rule #1 #2 #3, 4, 5 Description Defines SSH access to the Digi CM unit (port 22). The Normal option specifies that the rule applies to all addresses listed. The rule says to Accept traffic from these addresses for Port 22. Defines Telnet access to the Digi CM unit (port23). The Invert option specifies that the rule applies to all addresses except those listed. The rule says to Drop traffic from all addresses not listed. Define access to the Digi CM unit using HTTP (port 80). Rule 3 blocks all traffic. Rule 4 allows access from IP address Rule 5 allows access from IP address Allowable Hosts Input format Base Host IP Address Subnet mask Any host Chapter 8

77 Configuring Security and Authentication Configuring User Access Control Another method for controlling access to the serial ports on the Digi CM unit is the User Access Control configuration. You can set up this configuration either globally (using the All Ports option) or per port. It is not necessary to have users added to the system to assign rights. However, for the permissions or restrictions to be enforced, the username must match exactly. The username is case sensitive, and the application does not recognize misspellings. To add users, click on "System administration > Users administration". For details about adding users, see "Administering Users" on page 69. Note: Users do not need to be authenticated locally; they can be users on any configured authentication server. Using Access lists, you can add rights to a single user or to multiple users at the same time. In addition, you can group multiple users and assign one, some, or all these rights: Port access rights Port monitor rights Power management rights to an access list. For more information, see "Create an Access list" on page 70. This scenario shows a configuration with a restricted user: Joe does not have access to the Sun server, while Mike does. MIKE JOE Your strategy for assigning rights to a port can include: Allowing <<Everyone>> access to a port and then restricting access to certain users -or- Specifying each individual user and their specific rights to a port Chapter 8 77

78 Configuring User Access Control Adding a user to an established group (Access list) with preconfigured rights to a port. If you check <<Everyone>>, all users, whether they are configured locally or are using a remote authentication (such as LDAP or Kerberos), have access to this port. If you do not check <<Everyone>>, no users are allowed to access this port unless they are individually listed. When you enter usernames for access permissions or restrictions, you must enter the username exactly as the username on the remote authentication server or configured locally. The username is case-sensitive. In the next example, three users are configured on the Digi CM unit: Jeff, Tim and Paul. To give Tim and Paul read/write access and power access to this port, you could either: Grant rights to Paul and Tim Restrict Jeff s rights Add users to an Access list (in this example. sun-users) found under System administration > Access list. For more information, see "Create an Access list" on page Chapter 8

79 Configuring Security and Authentication Configure User Access Privileges To configure user access privileges: 1. Select Serial Port Configuration > All Ports (or Port #) 2. Click User access mode 3. Enter the users and their privileges, and click Add user. Restrict a User s Privileges To restrict user access: 1. Under Port configuration > User access control 2. Enter privileges for <<Everyone>>. 3. Enter restricted user s name (Here it is Jeff). 4. Enter the privileges this user has. (Notice that <<Everyone>> has more access than Jeff does.) Chapter 8 79

80 Configuring User Access Control Note: The usernames and passwords on the Digi CM unit are case-sensitive. Notice <<Everyone>> has access to Port, Monitor, and Power, while Jeff has access to only Monitor, with no Port or Power access. Change the Privileges of an Access List 1. On the same screen shown in the previous procedure, select an access list from the drop-down box. 2. Click the Add access button, and then click and the Save & apply button. When you add the access list, it will include Paul and Tim. In this screen, the "sun-users" Access group has access to Port, Monitor, and Power, while any other users (<<Everyone>>) do not have access. 80 Chapter 8

81 Configuring Security and Authentication Type of Users Access Types How to Permit or Restrict Only specific users have access "Permitted Users" All users have access except for a few "Restricted Users" Access type is unchecked for Everyone (meaning All other users) does not have access Everyone has access to everything by checking the access types. If an access type is unchecked, all users are restricted from that access type. By listing specific users and checking the access types - (Permitting them access) By listing users and unchecking the access type they are restricted from using Sniff Session A sniff session enables multiple users to access a single serial port for viewing the data stream. Anyone who is registered for a sniff session can access a specific serial port even if someone else is using the port. The Digi CM unit supports multiple concurrent sniff sessions. serial log in port 3 Sniff Session (Read only access) Port 3 Network (Ethernet) log in port 3 Sniff session mode has four options: disabled, input, output, and both. You configure the sniff session modes per port from the serial port configuration page. Enable/Disable sniff mode Main Session (Read/write access) Disabled - No one can enter a sniff session after the first user logs on. Enabled - Allows all users with access the following options in sniff mode: Chapter 8 81

82 Security Profile Sniff session display mode server output - View all data to a serial port from a remote connection user input - View all data from a serial port to a remote connection both - See all data transmitted or received through a serial port Display data direction arrows Enable/Disable - Displays arrows to indicate the direction of data to or from the server. When the second user accesses the port, the global "Port escape menu" is displayed. See "Port Escape Menu" on page 21. Permit monitor only mode Enable: A user with Monitor" permissions can only connect to the port in read only mode any time. Disable: A user with Monitor" permissions can connect if a read/write user has a connection to the port. A read-only session is automatically disconnected if the main user (read/write session) disconnects from the port. Security Profile The Security Profile tab, available under System Administration > Security Profile, provides a centralized access for enforcing site-appropriate, minimum security parameters on the CM. These are the available control mechanisms: System Security Password Security (Force heightened) System Security SNMP The CM allows you to use Get and Set commands for easy remote configuration and monitoring. You can configure Get and Set individually using the Network > SNMP Configuration interface. This option gives you a simple method for globally disabling any SNMP queries. (Traps always can be sent if they are configured). In the Default configuration, SNMP is disabled. Discovery (ADDP) Enables/disables the discovery protocol. While this is convenient for initial discovery of units on the network, this service is often disabled when the system is ready for production, unless the system is deployed on a controlled LAN. Telnet Disabled by default, this feature can be enabled afterward if the customer does not plan to use network security. SSH Usually remains enabled; in some environments, however, access is allowed only by a totally out-of-band connection (hard-wired serial, dial-up modem, or both). In such situations, the Ethernet connection is used only for reports and alerts. 82 Chapter 8

83 Configuring Security and Authentication SSHv1 SSHv1 (Secure Shell Version 1). SSHv1 uses server and host keys to authenticate systems. This service is disabled by default. HTTP Enables/disables access to the Digi CM using the Web interface. By default, HTTP is redirected to HTTPS. HTTPS Enables/disables access to the Digi CM using the Web interface. This service is enabled by default. If, however, the unit will be deployed outside a controlled LAN, HTTPS is often disabled to limit the number of services available. All Ports Enables/disables access to all ports using any protocol. Set all ports to Specifies the protocol to be used on all ports. The default is Telnet. Stealth Mode Makes the Digi CM invisible on the network and exposes only ports that are used to provide access. In Stealth Mode, the CM does not reply to pings or traceroutes and does not respond to communication attempts on unused TCP/UDP sockets. Password Security To enhance password security, you can use these settings: Minimum password length - Allows passwords that are 3 to 255 characters long; also allows spaces in passwords Maximum password age - Specified in days. To disable this setting, enter 0. Enforce password complexity - Cannot include all or part of a user s account name. Passwords must be at least eight characters long. If you enable Minimum Password Length, passwords can be characters long and must include three of these four categories of characters: English uppercase characters (A-Z) English lowercase characters (a-z) Base 10 digits (0-9) Non-alphabetic characters (!, $, #, %, and so on) Enforce password history - Cannot reuse the last nine passwords Chapter 8 83

84 Authentication Authentication The Digi CM unit supports multiple methods of user authentication, including local, TACACS+, RADIUS, RADIUS Down-Local, LDAP, Kerberos, and Custom PAM. The authentication protocol you use depends on your environment. 4. Access granted Server 1. Connection request 2. Query User ID PC 3. Accept User ID Authentication server Configuring Authentication Methods for Port Access You can choose between having a single authentication method, such as RADIUS, or an authentication method where a Local authentication service is used in addition to the RADIUS, LDAP, TACACS+ server, or Kerberos. These options are listed when you configure the Digi CM unit for authentication. To configure the Digi CM unit for authentication, do the following: 1. Access the web interface. 2. Under the Serial port heading, choose Configuration. 3. Choose All or an Individual port > Authentication. 84 Chapter 8

85 Configuring Security and Authentication 4. From the drop-down menu, choose an authentication method. A configuration screen for the authentication method you choose is displayed. This figure displays the options for setting up a RADIUS server as the primary authentication server and Local authentication if the primary authentication method fails. Note: Remote authentication to Port access menu can be obtained from Serial port > Configuration > Port access Menu 5. Fill in the applicable fields. 6. Choose Save & apply changes. Configuring Authentication for the Web Server 1. Access the web interface. 2. Choose Network > Web server configuration. This screen opens. 3. Choose an authentication method and then Save & apply. When you are using remote authentication for the web server, such as RADIUS, RADIUS Down-local, TACACS+, LDAP, Kerberos, or Custom PAM, you must also be added to the local database. The user password must be different from local authentication; otherwise, the CM will authenticate against the local database instead of the remote one. For details, see "Administering Users" on page 69. Chapter 8 85

86 Configuring Authentication for the Web Server When your password is approved by the authentication server, the Digi CM unit uses the local permission rights to provide access privileges for you to ports and the configuration. LDAP Authentication The Digi CM unit supports authenticating against an LDAP-based database, including LDAP systems running on Linux servers as well as Microsoft Active Directory together with the LDAP gateway ADAM (Active Directory Application Mode). If the Digi CM unit authenticates against an LDAP directory, all users must be configured in one container. The Digi CM unit will extend the username using the LDAP search base and authenticate the user. In the next example, the domain is called dilbert.com, the LDAP server is at , and all users with access to the Digi CM unit are located in the container: USA Users Configure the LDAP authentication as shown here: Authentication method: LDAP server First LDAP Server Second LDAP Server LDAP search base: ou=users,ou=usa,dc=dilbert,dc=com Domain name for active directory: If your LDAP database resides on a Microsoft system you also have to configure the Domain name for the active directory (dilbert.com in the above example). Do not use this setting if you are using a non-microsoft system as it changes the LDAP to comply with Microsoft syntax. Custom PAM Module The Digi CM unit supports custom PAM modules for remote authentication. This allows you to create your own authentication schema or use any other third party PAM module. The module must o be compiled for the Digi CM unit s environment. Digi offers an SDK for the Digi CM family. To download the SDK, contact technical support at support.wizards@digi.com 1. Place the custom PAM modules onto: /usr/2 on the Digi CM unit. 2. Use an scp client (like WinSCP) to copy data to the /usr2 directory, or download the ftp client for the Digi CM unit from support.digi.com. 3. Make sure the module is flagged to be executable (chmod ) Note: To activate the custom PAM module it has to be configured in the custom file located in /etc/pam.d 4. Create a file called: /etc/pam.d/custom and add these lines: auth required /usr2/my_pam _auth.so session required /usr2/my_pam_ auth.so (with the my_pam_auth.so being the "custom pam" module s name) 86 Chapter 8

87 Configuring Security and Authentication 5. To keep this file permanently copy it to /usr2 and add a line to /usr2/rc.user. Cp /usr2/custom /etc/pam.d/ Example of an rc.user file: #!/bin/bash # # rc.user : Sample script file for running user programs at boot time # #PATH=/bin:/usr/bin:/sbin:/usr/sbin # Add shell command to execute from here cp /usr2/custom /etc/pamd/ exit 0 Chapter 8 87

88

89 Custom and Default Menus Chapter 9 Custom and Default Menus Introduction The Digi CM unit has several default menus for easy configuration and access by different users. Depending on access privileges, the menus available are the Web Interface, Configuration Menu, and Port Access Menu. A Custom Menu feature for creating menus is also available through the web interface. The Custom Menu feature enables system administrators to create menus for specific users; in other words, system administrators can create a customized interface to selected ports. Custom menus can only be configured via the web however, they can only be accessed via the shell (command line). Making Custom Menus Before making custom menus, plan the kind of menus and menu items you want available to your users. A good plan would include the following: 1. Add users to the system. 2. Create a menu name with sort and display features. 3. Add menu items and submenus to the new menu. 4. Assign users to the menus. Adding Users You cannot assign users to a menu until you have added users to the system. To add users, do the following: 1. Access the web interface. 2. System administration > Users administration > Add Chapter 9 89

90 Making Custom Menus 3. Enter the User name and User group from the drop down menu.select Custom menu from the drop down menu for the Shell program. 4. Click Add to add the user. 5. Continue to add users as needed. Note: You do not need to Save to flash or Apply changes to add users. Creating Menu Names To make a custom menu, do the following: 1. Access the web interface. 2. Custom Menu > Configuration. 3. Enter the Menu Name to assign and click the Add Menu button. The menu is added. 4. Click the hyperlink to the menu you just created. 5. From the drop down menu, select the way to Sort and Display items. 6. Click Save & apply. 7. Repeat as required to create additional menus. 90 Chapter 9

91 Custom and Default Menus Adding Menu Items Once you have defined a menu name and added users, you can then add menu items. To add menu items, do the following: 1. Custom Menu > Configuration > Menu Name hyperlink for the menu you want to configure. 2. Choose Menu Items > Add Item. The following screen appears. 3. Fill in the desired parameters. The parameters are: Key - Assign any letter or number except a value already used by another menu item. Label - Assign a label or name for the menu item. Create new submenu - Assign a name for a new submenu that this menu item will be assigned or linked to. Go to existing submenu - Choose an existing submenu from the drop down menu that this menu item will be assigned or linked to. Connect to serial port - Connects you to a specified port. Connect to clustered serial port - Connects you to a clustered port. Telnet to a remote host - Enter a remote host s IP address or hostname. SSH (Secure Shell) to a remote host - Enter the hostname or IP address of a remote host and the remote username. Execute a custom command - Enter a customized command that is any valid command on the command line with acceptable user privileges. Chapter 9 91

92 Default Menu 4. Choose Apply. 5. Repeat this procedure to add more menu items. Note: To add or configure submenus, select the Submenus hyperlink on the Menu Configuration page. Assigning Users to a Menu Once a menu has been created, users can be assigned to the menu by doing the following: 1. Access the web interface. 2. Configuration > Custom Menu > Menu Users. A list of available users is displayed. 3. Choose a menu for a user by selecting a menu from the drop down Assigned Menu list. 4. Choose Save & apply. Default Menu Port Access Menu The Port Access menu is a flat (one level) menu showing all ports, port titles and the mode of each port. Using the Port Access menu you have a complete overview of all ports and can initiate a connection to any of them. When you choose to connect to a specific port, you are prompted again for the username and password. 92 Chapter 9

93 Custom and Default Menus There are multiple ways to access the PortAccess menu: Assigned IP address (see "Configuring Host Mode" on page 54) TCP/IP port 7000 TCP/IP port 22 or 23 if the Shell program is set to port access menu for this specific user (see chapter "Administering Users" on page 69) By calling portaccessmenu from the command line The PortAccess menu allows simple access to each port. By typing the number of the port to connect to, the Digi CM unit initiates a connection to this port using the appropriate protocol (Telnet of SSH). You can also change your own password by using the P Key. If the Digi CM unit is configured to be the master in a master-slave scenario, the S key will bring up a list of all slaves. Selecting a slave will then spawn a connection to the Port Access Menu of the slave. When using a Digi CM 48, not all ports can be displayed on one screen. Ports can be viewed after hitting the <Enter> key. Chapter 9 93

94

95 Microsoft SAC Support Chapter 10 Microsoft SAC Support About the Digi CM Unit s Support for Microsoft Windows Server 2003 The Digi CM unit provides a browser-based user interface to Microsoft s textbased Special Administration Console (SAC), an integral part of Windows Server 2003 Emergency Management Services (EMS). Both the English and Japanese versions of SAC are now supported. When a server running Windows Server 2003 is connected to the Digi CM unit s serial port, key SAC functions--normally accessed from the command line--are available from a graphical user interface (GUI). SAC features accessible from this interface include: Reset and shutdown Show performance values like memory utilization Show and configure IP settings per interface Show the process list and kill processes Note: While the EMS port is available at all times using Telnet or SSH, the special GUI is available only while SAC is active. Chapter 10 95

96 Setup Overview Setup Overview Setup for the Digi CM unit SAC support is a three-step process: 1. Set up the Windows Server 2003 for SAC support. To do this, ensure that the COM port used for console traffic is properly set up. This includes designating a COM port for console communication and setting the port speed (baud) appropriately. For further information please refer to Setting Up the Windows Server 2003 Port below. 2. Cable the console port on the Windows Server 2003 to the Digi CM unit s port. See the cabling information in Chapter. 3. Set up the Digi CM unit for SAC support. See "Setting Up the Digi CM Unit for SAC Support" on page 96. Setting Up the Windows Server 2003 Port 1. Sign on to the Windows Server 2003 as the administrator. 2. Access the command line. 3. Use the bootcfg command to redirect console traffic to the correct COM port. The following is the command syntax and an example. See the Microsoft documentation for additional information on the SAC feature. Command Syntax bootcfg /ems on /port com# /id # /baud where: com# is the COM port to which console traffic will be redirected. # is the is the number of the boot entry. The port speed is set to the recommended rate (although you can use any rate supported by Windows Server 2003). Command Example In this example, console output is redirected to COM 2, the boot entry is specified as 1, and the port speed set to bootcfg /ems on /port com2 /id 1 /baud Setting Up the Digi CM Unit for SAC Support To set up a serial port to provide access to the Windows Server 2003 console port, do the following: 1. Access the web interface. 2. Choose Serial port > Configuration. 3. Choose a port. 4. Choose Host mode configuration. The Host mode configuration page appears. 5. Set the Host mode to Console server and the Type of console server to MS SAC -English (or Japanese) console as shown in the following figure. 96 Chapter 10

97 Microsoft SAC Support 6. Set other fields as appropriate. 7. Click Save & apply. 8. Configure serial port communication settings, by doing the following: a. Choose Serial port parameters from the menu. b. Adjust settings as required. This includes ensuring that the Baud rate matches the setting on the Windows Server 2003 serial port and Flow control is set to None. Ignore the DTR behavior field. c. Click Save & apply. Chapter 10 97

98 Accessing the Windows Server 2003 Console Port from the Digi CM Unit s GUI Accessing the Windows Server 2003 Console Port from the Digi CM Unit s GUI To access the Windows Server 2003 console port, do the following: 1. Access the web interface. 2. Choose Serial port > Connection. A screen similar to the following appears. 3. Click on the title of the port to which the Windows Server 2003 console port is connected. Note: If support for "Windows Server 2003" and "Rackable Systems Management Card" is selected a menu will appear and you must choose between the two functions. A screen similar to the following appears. 4. Use the Digi CM unit s GUI to perform SAC functions. The following table describes attributes of the controls on the GUI. 98 Chapter 10

99 Microsoft SAC Support Field Connect Description Connects to the SAC console port via the command line interface. Restart Reboots the Microsoft Server Shutdown Performance Process Serial Port Log IP Settings Shuts down the Microsoft Server Caution! This switches off the server and you can no longer access it remotely. Provides access to Microsoft Server 2003 status information. Provides access to the process list, which allows you to view and kill active processes. Provides access to port logging information. Provides access to IP settings, enabling you to verify and change settings. Chapter 10 99

100

101 Configuring Virtual KVM Chapter 11 Configuring Virtual KVM Introduction The Digi CM provides a method for gaining access to the graphical interface of a system using the network. Using this method, Virtual KVM, you specify a connection method and IP address to use to reach the system. Supported methods include: Microsoft Remote Desktop Protocol VNC XManager for X Window System A user-defined option An Example Configuration This diagram shows the Digi CM managing a Linux SuSE 9.2 system, a Windows 2003 system, and an HPUX system. Virtual KVM Protocols This table lists the Virtual KVM protocols and the client software with which each protocol has been tested. Virtual KVM Protocol Remote Desktop VNC X Window System Tested Client Software Windows 2000, XP, 2003 Remote Desktop Client Linux: rdesktop Windows: tightvnc, realvnc, UltraVNC Linux: vncviewer Windows: Xmanager Linux/Unix: X Window System Chapter

102 Using Virtual KVM with Remote Desktop Protocol The rest of this chapter describes how to set up Virtual KVM with each of the supported methods and connect to a system through Virtual KVM. Using Virtual KVM with Remote Desktop Protocol This section describes how to: Configure Virtual KVM with Remote Desktop Protocol Connect to a system through Virtual KVM using Remote Desktop Protocol Configuring To set up Virtual KVM with Remote Desktop protocol, follow this procedure: 1. Access the Digi CM Web interface and log in. 2. Choose Serial Port > Configuration. This window opens: 3. Choose the port you want to configure, and then select the Virtual KVM tab. (In this example, port 1 is selected.) 102 Chapter 11

103 Configuring Virtual KVM A window similar to this one opens, showing the serial port number and title: 4. Click Virtual KVM configuration. This window opens: 5. From the drop-down list next to Virtual KVM configuration, select Enable. Then, from the Client program drop-down list, select Windows remote desktop connection. 6. If you are not using IP automatic detection, enter the IP address. 7. Click the Save & Apply button. Note: If you are using Remote Desktop configuration and you want to use automatic IP address detection, configure the host mode for the port to MS SAC console before you configure the Virtual KVM feature for the port. For more information, see "Setting Up the Digi CM Unit for SAC Support" on page 96. Chapter

104 Using Virtual KVM with Remote Desktop Protocol Connecting to a system through Virtual KVM using Remote Desktop Protocol When you connect through the Connection window, and a Virtual KVM connection is configured, you now see: The terminal monitor button, which connects to the raw ASCII SAC console A mouse button (next to the monitor icon), which connects to the Virtual KVM graphical interface The manage button, which connects to the SAC GUI screen To connect through Virtual KVM using Remote Desktop, follow these steps: 1. Click on the mouse icon. 2. Click OK in each of the three Java confirmation request windows. The applet first checks whether the optional Virtual KVM Assistant is installed on the system. Then: If the applet is installed, it starts Virtual KVM Assistant to manage the connection. If the applet is not installed, the attempt to launch the Virtual KVM assistant fails, and the applet tries to launch the connection directly. If the Virtual KVM Assistant is not installed, a message indicates that the first connection attempt failed. A second message indicates that the second connection attempt succeeded. This is normal behavior if the applet does not find the Virtual KVM Assistant. (For more information, see "Virtual KVM Assistant" on page 112.) 104 Chapter 11

105 Configuring Virtual KVM The application starts and you see a message that the connection succeeded: This login screen opens: 3. Enter your user name and password, and then click OK. If the application does not start, check to make sure that the application is in the search path on your server. See "Installing Programs for Virtual KVM" on page 113. Using Virtual KVM with VNC Protocol This section describes how to: Configure Virtual KVM with VNC Protocol Connect to a system through Virtual KVM using VNC Protocol Configuring To configure Virtual KVM with VNC protocol, follow this procedure: 1. Access the Digi CM Web interface and log in. 2. Choose Serial Port > Configuration. Chapter

106 Using Virtual KVM with VNC Protocol This window opens: 3. Double-click the port you want to configure. A window similar to this one opens, showing the serial port number and title: 4. Select the Virtual KVM tab. 106 Chapter 11

107 Configuring Virtual KVM This window opens: 5. From the Virtual KVM connection drop-down list, select Enable. Then, from the Client program drop-down list, choose the VNC Client program. 6. Adjust the VNC socket/screen number, if necessary (the default is 1). 7. Click on the Save & Apply button. Connecting to a system through Virtual KVM using VNC When you connect through the Connection window, and a Virtual KVM connection is configured, you now see: The terminal monitor button, which connects to the serial console A mouse button (next to the monitor icon), which connects to the Virtual KVM graphical interface Chapter

108 Using Virtual KVM with VNC Protocol To connect through Virtual KVM using VNC: 1. Click on the mouse button. 2. Click OK in each of the three Java confirmation request windows. The applet first checks whether the optional Virtual KVM Assistant is installed on the system: If the applet is installed, it starts Virtual KVM Assistant to manage the connection. If the applet is not installed, the attempt to launch the Virtual KVM assistant fails, and the applet tries to launch the connection directly. If the Virtual KVM Assistant is not installed, a message indicates that the first connection attempt failed, and then another message indicates that the second connection attempt succeeded. This is normal behavior if the applet does not find the Virtual KVM assistant. The application starts, and you see a message that the connection succeeded: The Virtual KVM VNC Connection opens: 3. Enter your user name and password, and click Login. If the application does not start, check to make sure that the application is in the search path on your server. See "Installing Programs for Virtual KVM" on page Chapter 11

109 Configuring Virtual KVM Using Virtual KVM with X Window System Protocol and XManager Software This section describes how to: Configure Virtual KVM with X Window System Protocol and XManager Software Connect to a system through Virtual KVM with X Window System Protocol and XManager Software Configuring To set up Virtual KVM with X Window System Protocol and XManager Software, follow this procedure. 1. Access the Digi CM Web interface and log in. 2. Choose Serial Port > Configuration. You see this window: 3. Choose the port you want to configure. Chapter

110 Using Virtual KVM with X Window System Protocol and XManager Software A window similar to this one opens, showing the serial port number and title: 4. Choose Virtual KVM configuration. This window opens: 5. From the Virtual KVM connection drop-down list, select Enable. Then, from the Client program drop-down list, choose the Xmanager program. 6. Click Save and Apply. Connecting to a system through Virtual KVM using Xmanager When you connect through the Connection window, and a Virtual KVM connection is configured, you now see: The terminal monitor button, which connects to the serial console A mouse button (next to the monitor icon), which connects to the Virtual KVM graphical interface 110 Chapter 11

111 Configuring Virtual KVM To connect through Virtual KVM using X Window System Protocol and XManager Software: 1. Click on the mouse icon. 2. Click OK for each of the three Java requests in pop-up windows. The applet first checks to see if the optional Virtual KVM Assistant is installed on the system: If the applet is installed, it starts Virtual KVM Assistant to manage the connection. If the applet is not installed, the attempt to launch the Virtual KVM assistant will fail, and the applet tries to launch the connection directly. If the Virtual KVM Assistant is not installed, a message indicates that the first connection attempt failed, and then another message indicates that the second connection attempt succeeded. This is normal behavior if the applet does not find the Virtual KVM assistant. (For more information, see "Virtual KVM Assistant" on page 112.) The application starts, and you see a message that the connection succeeded: Chapter

112 Virtual KVM Assistant The Virtual KVM VNC Connection comes up: 3. Enter your user name and password, and click OK. If the application does not start, check to make sure that the application is in the search path on your server. See "Installing Programs for Virtual KVM" on page 113. Virtual KVM Assistant Digi provides an optional tool, Virtual KVM Assistant, that can be loaded on a Windows or Linux system. When the Virtual KVM Assistant is loaded, it registers itself with the browser so it can manage requested connections. It creates a drop-down list of the available Virtual KVM sessions and provides a floating dashboard, shown here: The floating dashboard allows fast access, without going through the Web UI, to the: Serial Console Serial Console Log Power Controller, if it is configured How the Virtual KVM Assistant Works Users access the remote desktop of Windows Servers using the CM web page. Virtual KVM Assistant appears on the screen: 112 Chapter 11

113 Configuring Virtual KVM Serial Console Console Log Power Control To switch between multiple connections, choose the item from the dropdown list. To view the console logs, connect to the serial console, or cycle the power, use the buttons on the dashboard. User Client PC platforms Supported Windows XP/2000/NT Linux Users need to download the program to use it. The Digi CM java applet automatically detects the program if it is present and in your path. Installing Programs for Virtual KVM Virtual KVM relies on software installed on the client system to provide access to the target system. This section is for troubleshooting common issues that may come up as you use Virtual KVM. Because the Virtual KVM is launched by a Java applet, you must have Java installed on your Workstation and in your browser. Regardless of the software package you use, make sure that the server has support for that package enabled. Remote Desktop Protocol Software Needed Remote Desktop Client software is provided as part of the standard installation of Windows for Windows 2000, 2003, and XP systems. Generally, there are no issues, because it is installed in the windows\system32\ directory. A Remote Chapter

114 Installing Programs for Virtual KVM Desktop Client program is standard in major Linux distributions and is available as an open source package that can be installed if it s not already present. Make sure the Remote Desktop Client is in your user path on your Linux/Unix server. Usage Notes You can perform applications management and most diagnostics from the standard Remote Desktop connection. On Windows Server 2003, however, note that there are actually two different types of connection one for general access and one to take over the primary VGA data stream. Some applications may require access to the VGA data. Windows systems prior to Server 2003 provide the VGA facility on the standard data stream. To get to the VGA video stream, do either of these steps: Install additional software (tsmmc.msc) on your XP system. At the command line, change the command in Virtual KVM from: $RDC$ to: tsmmc.msc The VGA video stream is available for WinXP in the Win 2K3 administrative service pack for Win2K3, on the Windows Server 2003 CD, or online from: f4b0e7e02e.mspx or Make a standard remote desktop connection to the W2k3 server and then run the tsmmc command remotely on the target W2k3 server. The advantage of this method is that it doesn t require any additional software to be loaded onto Windows systems, and it works equally well with Remote Desktop Client from Linux and Unix workstations. To reach the VGA data stream from within an existing RDP connection: 1. Log in with RDP. 2. Choose Start > Programs > Administrative Tools > Remote Desktops. 3. Under Console Root, right-click on Remote Desktops > Add New Connection > Use IP Address Right-click on > New Window From Here > Log In. To enable Remote Desktop on your Windows Server 2003 System, choose My Computer > Right Click > Properties > Remote > Enable Remote Desktop on this Computer. VNC Viewer Client Software Needed Windows: TightVNC from RealVNC software from UltraVNC from Chapter 11

115 Configuring Virtual KVM Linux: vncviewer from the VNC client software package for your distribution. Make sure that vncviewer is installed into a folder in your standard Windows or Linux/Unix path. On Windows systems, as a secondary option, you can copy the vncviewer.exe file to your c:\windows directory. Usage Notes Follow the distribution-specific instructions for enabling VNC support on your Unix or Linux Server. Xmanager Client Software Needed The Xmanager software is available for free 30 day evaluation download from Usage Notes Install the client software in a directory in the PATH of the Windows system; otherwise, you must update path to include the base directory for the Xmanager software. Make sure that X Window System is configured to allow for remote connections from your Client workstation s IP address. Full documentation of Xmanager capabilities is included with the evaluation download. Chapter

116

117 Rackable Systems Management Card Chapter 12 Introduction Rackable Systems Management Card Rackable Systems manufactures a management card that is built into some of their servers. It interfaces between the Digi CM unit and the server s serial port. In normal mode, it allows transparent communication between the Digi CM unit and the server. After detecting an escape sequence, it allows you to control functions from the server independently of the main processor. The controllable functions are listed below: Switching power on or off Rebooting Turning the status LED on or off Programming the LCD panel Reading the temperature from inside the server Setting the power on delay The Digi CM unit offers a graphical web based user interface to manage the Rackable Systems Management Card. Set up Setup of the Digi CM Unit to Support the Rackable Systems Management Card To set up the serial port to provide access to the Rackable Systems Management console, do the following: 1. Access the Digi CM unit s web interface. 2. Under the Serial Port heading choose Configuration. 3. Choose a port. 4. Choose Host mode configuration. The Host mode configuration page appears. 5. Set the Host mode to Console server. 6. Set the Rackable Systems Mgmt Card support to Enable. 7. Click Save & apply. Configure Serial Port Communication Settings: 1. Choose Serial port parameters from the menu. 2. Adjust the settings as required. The defaults for the Rackable Systems Management Card are identical to these of the Digi CM unit: Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None Chapter

118 Set up DTR behavior 3. Click Save & apply. High when open Assign a Port Name: 1. Choose port title from the menu. 2. Enter a port title. 3. Click Save & apply. Accessing the Rackable Systems Management Card from the Digi CM Unit s User Interface 1. Access the Digi CM unit s web interface. 2. Under the Serial Port heading choose Connection. A screen similar to the following appears. 3. Click on the icon in the M (Manage) column or on the title of the port to which the Rackable Server is connected. A screen similar to the following appears. 118 Chapter 12

119 Rackable Systems Management Card 4. Use the Digi CM unit s user interface to perform Rackable Systems Management Card functions. The following describes attributes of the user interface controls.. Field Control Power status Reboot Connect LED Mgmt LED Management LCD Mgmt Currently displayed message Erase Save Description The first column shows the current state. Three buttons are available to initiate an action to either, power on, power off or restart the server. Dependant on the current status Power on or Power off is disabled. Reboot the Rackable Server by sending a 500ms reset signal to the server. Spawn the Java Telnet applet or the local Telnet/SSH application to connect directly to the port. To control the LED in the front of the Rackable Server. The first columns shows the current status of the LED. Three buttons are available to select the activity of the status LED: turn on, turn off and blinking. Either of these buttons is disabled. Shows the message that is currently displayed on the LCD display. This function clears the LCD display. The saved message stays saved to flash. Save currently displayed message to flash memory. Chapter

120 Set up Field Show saved LCD message upon startup Contrast Phantom Properties Temperature Power delay Power sense Communication settings Baud Rate Description The first columns shows the current status: Yes or No. This parameter defines which message is displayed upon startup of the server, either the saved message or the standard: Rackable Systems Phantom Vx.xx. Set a contrast for the LCD panel. The default is 50, the range is Indicates current temperature inside the Rackable Systems Server. Time in seconds before the server starts up after applying power (0-98 seconds, 99 means no power on delay). The power sense option toggles between sensing server power on the reset header or on the J7 connector. Most applications will use the Reset option. This option should be set before shipping from Rackable Systems, but may need to be reset if somehow changed after shipping. Configure the baud rate used to communicate with the Rackable Systems Management Card. For this change to become effective reset or power-cycle the Management card, and be sure to switch the port settings in the Digi CM unit s port settings. 120 Chapter 12

121 Configuring Remote Dial-In Access Chapter 13 Configuring Remote Dial-In Access Introduction The Digi CM unit supports dial-in connections from remote sites for out-ofband access. In this configuration, the Digi CM unit has serial ports configured for external modems and waits for dial-in connections from remote sites. If you dial-in using a terminal application, the Digi CM unit accepts the connection and displays a menu of available serials ports. In a dial-in terminal server mode, the Digi CM unit makes a TCP connection with either a Telnet or SSH client to a pre-defined server. RawTCP is also an option for dial-in users. For more information on the different types of Host mode configuration, see "Host Mode Configuration" on page 52. Configuring for Dial-In Modem Access To configure a serial port for a dial-in modem, enter the values for these fields: Host mode, Modem init string, and Inactivity timeout. To access the Host mode configuration screen, do the following: 1. Access the web interface. 2. Under the Serial port heading, choose Configuration. 3. Choose a specific port under Individual port configuration and then choose Host mode configuration. 4. Select Dial-in modem for the Host mode in the drop down menu. 5. Fill in the appropriate fields as they apply to your configuration. Modem init string - Chapter 13 The default modem init string is q1e0s0=2. The init string 121

122 Configuring for Dial-In Modem Access sets the modem to quiet mode, echo off, and Auto Answer on two rings. The modem init string is used for initializing an external modem attached to the Digi CM unit s serial port. See your modem user manual for more information. Callback - For security reasons, the callback feature can be activated. If callback is enabled, the Digi CM unit does not accept any incoming calls. After the incoming call is rejected, a callback is initiated to the phone number configured in the Dial-in modem callback phone number. Modem test - To ensure the proper functionality of the modem, the Digi CM unit has the ability to test the modem connection in a configurable interval. The modem test allows you to specify a phone number and an interval. 122 Chapter 13

123 Configuring Remote Dial-In Access After the system has booted, the interval has elapsed, and the modem is not in use, the specified dial number is called. The modem trains and receives a login prompt from the other side (normally another Digi CM unit). If the login-in prompt (login:) is detected the line is disconnected again and the modem test is considered successful. Two ports can call each other using this modem test procedure. Please be aware that the tests will fail if the other modem is in use. There are multiple ways to review the information about the mode test: syslog in the Digi CM unit: :45:01 > Port #16 - Modem Test started. Calling to :45:22 > Modem connected through Port # :45:22 > Port #16 - Modem Test succeeded In this example a modem connected to port 16 is calling another modem connected to port 15. Any errors occurring are captured in the syslog file as well. based notification The Alert configuration dialog of the port configuration, contains multiple settings: The title of the and the address can be configured. To be able to configure notifications, a primary SMTP server has to be configured under Network > SMTP configuration. SNMP configuration It is also possible to receive notifications using SNMP traps. When using SNMP traps the global settings for IP address, Community Chapter

124 Adding a PC Modem and Version can be used, or specified separately. The Trap MIB can be downloaded from support.digi.com (select your product and go to Diagnostics, Utilities and MIBs). 6. Click Save & apply. Adding a PC Modem A PC card slot is provided on the front panel of the Digi CM unit. The graphic below has an arrow indicating the PC card slot. PC card slot To install and configure the PC modem on the Digi CM unit, do the following. 1. Insert the card into the PC slot. 2. Access the web interface. 3. From the menu, choose Configuration under the PC card heading. 4. Choose Discover a new card. The Digi CM unit searches for a PC card and displays a configuration menu. 5. Enter the appropriate parameters in the configuration menu. 6. Click Save & apply. Configuring for Dial-In Terminal Server Access The host mode Dial-In Terminal Server is identical to the host mode Terminal Server but allows you to configure a modem init string. In this mode an incoming modem connection is automatically connected to an IP address. To configure a serial port for a dial-in terminal server access, enter the values for these fields: Host mode, Destination IP, Base Port, Protocol, Inactivity timeout, and Modem init string. To access the Host mode configuration screen, do the following: 1. Access the web interface. 2. Under the Serial port heading, choose Configuration. 3. Choose a specific port under Individual port configuration and then choose Host mode configuration. 4. Select Dial-in terminal server for the Host mode from the drop down menu. 5. Fill in the appropriate fields as they apply to your configuration. Digi CM 32 shown Destination IP - The IP address of the system that you will be automatically 124 Chapter 13

125 Configuring Remote Dial-In Access connected to when you access the port. Destination port - The TCP port that will be used when the port you accessed is automatically connected to a system on the network. Protocol - The protocol that will be used to establish the connection to Destination IP: port. The options are SSH, RawTCP, and Telnet. Inactivity timeout - The timeout length ranges from 1 to 3600 seconds; 0 is unlimited timeout. Modem init string - Use the default string or enter your own string. 6. Click Save & apply. Chapter

126

127 Power Controller Chapter 14 Introduction Power Controller The Power Controller feature allows the administrators of the Digi CM unit to use console management to control power functions. Power control consists of three basic functions: on, off, and reboot (power cycle). There are two typical scenarios when using a power controller. The simplest scenario is a non-serial device connected to a power controller (for example, an environmental sensor controller or a tape backup device). The power controller is configured and accessed through the Digi CM unit. This illustration shows the a power controller configured through the Digi CM unit for non-serial devices. The second scenario is a serial device (such as a router or server) managed through a port on the Digi CM unit with its power supply mapped through the power control feature. After configuration is complete, you need only reference the console management port on the Digi CM unit to also manage power. The Power Controller feature handles the relationship of a specific outlet to a serial device as if the power supply was also connected to the same port as the serial device. In other words, you don t need to see the physical connection or remember which outlet controls a specific serial device after configuration - the Digi CM unit does that for you. Chapter

128 Installing Power Controller The following illustration shows a Sun server configured through a serial port connection on the Digi CM 32. Installing Power Controller To connect the Digi RPM power controller to the Digi CM unit use the straightthru cable provided with the Digi RPM unit. Plug one side into the Console port of the Digi RPM unit and the other into any port of the Digi CM unit. If you plan to connect multiple power controllers, set up all of them as described before proceeding. For details on how to configure the Digi RPM unit for cascading refer to "Cascading Multiple Digi RPM Units" on page 136. If you are using any other manufacturer of power controllers, please refer to "About Serial Port Cabling" on page 185 for more information. Before proceeding, plug the power controller into an appropriate power source and turn it on. Note: The DIP switches on the Digi RPM unit are used for cascading. Make sure that the dip switches of the first unit are set to off. For more information about cascading refer to "Cascading Multiple Digi RPM Units" on page 136. Configuring Power Controller Only system administrators can add a power controller although authorized users may reconfigure outlets or serial ports. Configure the Serial Port Parameters to Match the Power Controller 1. Log in to the Digi CM unit (username root, password dbps). 2. Click Serial port > Configuration. 3. Select the port number of the serial port you want to connect to the power controller. 4. Select the Serial port parameters: Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control None DTR behavior High when open 5. Click Save & apply. 6. Continue by adding the power controller. 128 Chapter 14

129 Power Controller Add the Power Controller 1. Log in to the Digi CM unit (username root, password dbps). 2. Click Power Controller > Configuration. 3. Select the port number of the serial port you want have connected to the power controller(s), the manufacturer of the power controller, and the number of units to be cascaded (1 means that one unit will be connected (no cascading)). Note: The number of cascaded units cannot be changed later, so make sure you have all power controllers connected before proceeding. The default title is the manufacturer brand and the port number it is connected to. You have the ability to change this title in step 5 if needed. 4. Click Add controller. 5. After the controller is detected automatically, you can correct the number of ports if necessary or edit the port title. 6. Click Save & apply. 7. Continue by setting the alarms and thresholds. Chapter

130 Setting Alarms and Thresholds Setting Alarms and Thresholds Power Controller allows administrators to set an alert via notification or an SNMP trap when environmental conditions exceed specifications. 1. Under Power Controller click Alarms & thresholds. 2. Enter the appropriate parameters. Select the condition(s) for an alert and enter the information for the alert ( or SNMP trap or select both). Note: If multiple power management units are cascaded, the alarm threshold is set for the sum of all outlets. Note: To set up an alert it is assumed that the mail server has already been set up. If not, go to "Configuring SMTP Alerts" on page 62. If the SMTP server is not set up, the option will not be available. 3. Click Save & apply 4. Continue by configuring the outlets. 130 Chapter 14

131 Power Controller Outlet Configuration The following procedure allows you to setup the power supplied to your device from the power controller. 1. From Power controller, click Outlets. 2. Click the outlet number to configure. 3. Select the serial port number that controls the device connected to the Digi CM unit (if any). If the port number has a title, it will appear. Note: If you want to add a title or change the existing title, go to Serial port > Configuration and select the port number that you want to add or change the title. Enter the title and click Save & apply. Go back to Power Controller > Configuration > Title > Outlets and select the outlet you are configuring to continue. 4. If you are not selecting a serial port number, you can modify a user s access on this screen. Enter the User Access Control parameters - see "User Access for Power Controller" on page Click Save to flash and repeat steps 2-4 for each outlet you want to configure. 6. Click Save & apply. Chapter

132 User Access for Power Controller Note: The screen above shows that serial port one on the Digi CM unit is connected to a Sun Server that is supplied power from outlets 1 and 2 on the power controller. In the example above, Gilligan has access to the power outlets. 7. To select the parameters for the User Access Control, click the User Access link. You may grant specific users permission to access an outlet or restrict access for specific users from an outlet. For more information see "User Access for Power Controller" on page 132. User Access for Power Controller The Digi CM unit can be configured to allow all users or specific users access to the power controller feature as well as restricting specific users to the power controller feature. User Access is configured on an outlet by outlet basis. Note: User Access to a serial device that is connected to the power controller in configured under Serial Port > Configuration > Port # > User Access Configuring to Allow Specific Users Access To configure the Digi CM unit for specific users, you must deselect <<Everyone s>> access and add the specific user and access as in the following steps. 1. Log in to the Digi CM unit (username root, password dbps) 2. Click Power Controller > Configuration > Outlets > Select the outlet # to configure. 3. Select the port to configure to the outlet. If it is a non-serial device select None. 4. Edit the outlet title. If there is a serial port, the port title will appear and cannot be edited from this screen. 5. Click Save & apply. 132 Chapter 14

133 Power Controller 6. Under Everyone uncheck the Access type and click Save to flash. 7. Enter the user that will have access and check the Access type. Note: Port is access to the port. Monitor is access to sniff. Power is access to the power management. 8. Click Save to flash. Repeat steps 7 and 8 for additional users. 9. Click Save & apply after all users have been entered. Note: The screen above shows outlets 1 & 2 control power to the Sun Server configured on port 1 of the Digi CM unit. Outlets 3 and 4 are not serial devices. Gilligan has been designated the specific user to control outlet # 3. Configuring to Restrict Specific Users To restrict specific users, you must select access for << Everyone>> and add the restricted user by deselecting his or her access. 1. Log in to the Digi CM unit (username root, password dbps). 2. Click Power Controller > Configuration > Outlets > Select the outlet # to configure. 3. Select the port to configure to the outlet. If it is a non-serial device select None. 4. Edit the outlet title. If there is a serial port, the port title will appear and cannot be edited from this screen. 5. Click Save & apply. 6. Check Everyone and click Save to flash. 7. Enter the username that will NOT have access, uncheck the Access types that are restricted, and click Add. Chapter

134 Power Controller Management Note: Port is access to the port. Monitor is access to sniff. Power is access to the power management. 8. Click Save to flash and repeat steps 7 and 8 for additional users. 9. When all users have been added Click Save & apply. Note: Gilligan does not have access to Outlet # 4. Power Controller Management The Power Controller Management option allows you to change outlet settings or get a quick update of the power controller status. 1. Under Power Control click Management. The Power controller management screen gives a quick view of all the power controllers and the current status of the connection. The Port # and Manufacturer fields are a link to the specific power controller statistic page, which displays information for the power controller. If the status is Disconnected the links are inactive. 134 Chapter 14

135 Power Controller 2. Click either the Port # or the power controller title. The Power controller statistics screen appears to show the Alarm threshold, Current temp, Circuit breaker condition, RMS voltage, RMS current, and Max current detected. The Clear button will reset the Max current detected to 0.0 amps. From this screen click Outlets. 3. Select the outlet number that you would like to manage. Note: The screen below shows that all the outlets are powered On and outlet 3 is Rebooting, therefore the Backup Tape Device is power cycling. 4. Click Power on, Power off, or Reboot depending on what you want the outlet to do. Chapter

136 Cascading Multiple Digi RPM Units Cascading Multiple Digi RPM Units The Digi RPM power controllers can be cascaded when used with the Digi CM unit. The DIP switches on the front panel of the Digi RPM allow configuring unique identities (ID) to the Digi RPMs so they can be identified. In a cascaded environment each unit has to be configured to a unique ID. To cascade the Digi RPM units, connect a serial port of the Digi CM unit to the Console Port of the first Digi RPM unit using a straight-thru cable. Connect the Cascade Port of the first Digi RPM unit to the Console Port of the second. Following an example of two cascaded Digi RPM units connected to a Digi CM unit. Please note that the ID for the first unit is set to 0 and for the second unit it is set to 1. The next table shows all possible IDs that can be configured on the Digi RPM. 136 Chapter 14

137 Power Controller Chapter

138

139 Port Clustering Chapter 15 Port Clustering Introduction Port clustering is the ability to manage many serial ports on one or multiple slave devices from one master device using a single IP address. For instance, the Digi CM unit can manage up to 16 slave devices or a maximum 816 serial ports with one Master device. Ports can be configured either collectively or individually depending on user preference. Each master and slave device is configured separately; they cannot be configured from one master console. A secondary IP address can be specified to put all slaves on a private network. The secondary IP option can be found under Network > IP configuration. To set up the Digi CM unit for port clustering you will need to: Configure all the Digi CM serial ports Assign one Digi CM unit as the master clustering device; all other Digi CM units default to slave devices. Import slave configuration to the Digi CM unit s master device Remote PC Master Ports Local Slave Slave 2 IP Telnet Port 5 Server Slave Slave Chapter

140 Configuring Port Clustering Configuring Port Clustering Assigning Master Clustering Mode To assign a Digi CM unit as the master cluster device, do the following: 1. Access the Digi CM unit through the web interface. This Digi CM unit needs to be the unit you want as the Master. 2. Under the Clustering heading, choose Configuration. 3. Choose Master from the drop down menu. Subsequent units will be configured in Slave mode by default. 4. Choose Save & apply. Configure Slaves to Join a Cluster Digi CM units can be configured as basic slaves without any additional configuration. Two additional settings, however, enhance the clustering capability. Authentication mode -Local authentication is the slave independently authenticating all port access. Master authentication is the master performs port authentication. Users do NOT need to be defined on the slave unit. Password verification will be done by the master unit. Update Master on Changes -Automatically updates port name changes, port settings, and user permission settings to the master unit. Generally, Update Master on changes should be yes. 140 Chapter 15

141 Port Clustering Select the appropriate settings then click Save and apply. Advanced Clustering Configuration To refine a cluster environment, use the following parameters for advanced configuration of a cluster. To access the Advanced menu follow the proceedure listed below. 1. Select Clustering > Configuration > Master >Save & apply. 2. Select the port number > Enable > Save & apply. 3. Select Advanced from the Clustering >Master mode. Enable - This shows whether the port is enabled or disabled. All ports are enabled by default. Slave unit address - IP address of slave. No. of ports -Number of ports on slave. Chapter

142 Configuring Port Clustering Slave authentication mode - To specify if your database is controlled by the master unit, or locally by the slaves themselves. Update Master on Changes -Automatically updates port name changes, port settings, and user permission settings to the master unit. Generally, Update Master on changes should be yes. Connect to slave unit to change configuration - A quick access method to connect to the slave. Source port - This is the port number that you would access to get to the slave on the master unit. The first slave port defaults to 7100 for the port access menu and the port numbers increase according to the number of ports on the Digi CM unit. Destination port - The destination port is the corresponding port number on the slave unit. On a 32-port slave unit, the destination port numbers range from 7001 to Protocol - The four options are N/A (not available), SSH, Telnet, and RawTCP. Base source port -If you choose not to use AutoConfig, you can set these ports manually. Base source port is the first port number on a master unit. By default the base source port on the master unit is The base source ports extend the master s ports via the slave ports. For example, starting the base source port number with 7101 results in a 32-port unit being numbered from 7101 to Port number 7100 is the port access menu of the slave. If you configure the device manually, the port access menu must also be configured separately. Base destination port - The physical port numbers of the slave device. Note: However, you can change the base source port number to another number and the rest of the ports on the unit will be sequentially numbered from the base source port. 142 Chapter 15

143 Port Clustering Accessing the Cluster Ports You can connect to the slave port using the web, Telnet or SSH client. You can access the port access menu or custom menu of each slave device or connect directly to each slave port. Web Access 1. Click Clustering > Connection > Port number. 2. Log in to the port 3. Enter the port escape sequence (listed on page) Telnet 1. Telnet to the IP and the port number of the device. telnet Login and enter your password root dbps 3. Enter the port escape sequence (listed on page). SSH 1. Click on the port with SSH protocol 2. Login Chapter

144 Configuring Port Clustering 3. Enter the port escape sequence (listed on the page) Depending on your access rights you can sniff (read only) or monitor (read/ write), or manage power of the ports. 144 Chapter 15

145 System Administration Chapter 16 System Administration Introduction This chapter describes how to perform tasks performed either by root or the system administrator. These tasks fall under the general heading of system administration and include firmware upgrades, saving configurations, resetting the unit to defaults, and disaster recovery procedures. Upgrading the Firmware Web Interface The web interface allows you to download the latest firmware version to the Digi CM unit. The latest firmware can be found at: Do the following to upgrade the firmware: 1. Access the web interface. 2. Under the System administration heading, choose Firmware upgrade. 3. Select Local machine or CF card (if configured) 4. Choose the Browse button and locate the firmware download. 5. Choose Upgrade. The Digi CM unit will automatically reboot when the upgrade is complete. Note: Do not power cycle the unit for five minutes after the firmware upgrade is completed, as the unit is writing the firmware to flash! Chapter

146 Configuration Management Configuration Management Configuration management allows you to save all or parts of your configuration. You can also establish the time frame to save the configuration either periodically or 10 minutes after the latest changes. The Digi CM unit saves all configurations when the Save & apply button is used or the Apply changes link is used. These configurations are saved to the loca ldigi CM unit in /tmp/cnf directory by default. Manage these configurations by exporting the files to your location of choice. 1. Click System administration > Configuration management. The Configuration management screen appears. 2. Under Configuration Export, select the file locations that you wish to save enter a name and click Export. Automatically Saving the Configuration Further down the screen are the options for automatically saving the configuration either periodically or 10 minutes after the latest changes. The following list contains the parameter descriptions. Automatic backup option Disable - if you do not want to use an automatic save option Periodic - used to set the save option per your time frame 10 minutes after last change - as described Location CF card, Primary NFS server, User space, Send via - options for where to save the configuration Encrypt Yes - file will be encrypted (.syscm) No - file will not be encrypted (.tar.gz) in a tar and a gzip d format File Name The name of the configuration file 146 Chapter 16

147 System Administration Backup interval The periodic hourly interval to back up the configuration files. Recipient s address The address to send the configuration file. To setup the automatic backup option follow the procedure. 1. Select Periodic or 10 minutes after latest change from the drop down menu. 2. Select the location to save the file. 3. Select Yes or No to encrypt and enter the file name. 4. Enter the number of hours for the backup interval (if periodic) 5. Enter the recipient s address to send the configuration file (if the location is sent via ). 6. Click Save & apply. Automatically Upgrading the Digi CM Unit s Firmware or Configuration using TFTP The Digi CM unit supports upgrading the firmware, configuration, or any other files in the file system using a TFTP-based mechanism. During boot, the Digi CM unit can verify a hash file and determine if it needs to download upgrades from the TFTP server. There are multiple ways to configure the TFTP upgrade function. DHCP The DHCP server can automatically assign a TFTP upgrade server and file to the Digi CM unit during boot. The options implemented are: (66) TFTP server address (67) TFTP filename (this is the filename of the hash file) To enable DHCP firmware upgrade: 1. Click System administration > Firmware upgrade. Chapter

148 Automatically Upgrading the Digi CM Unit s Firmware or Configuration using TFTP 2. Set Automatic firmware and configuration upgrade at boot time to Enable. 3. Set Use DHCP option for remote server and hash file to Yes. 4. Click Save & apply. The next time the Digi CM unit reboots, it will analyze the hash file and upgrade the firmware, configuration, or other files if required. Directly Configure the TFTP Server and the Name of the hash File To configure the IP address of the TFTP server and the filename of the hash file on the Digi CM unit, follow the steps below: 1. Click System administration > Firmware upgrade. 2. Set Automatic firmware and configuration upgrade at boot time to Enable. 3. Set Use DHCP option for remote server and hash file to No. 4. Configure the IP address of remote server. 5. Configure the Hash file name". 6. Click Save & apply. The next time the Digi CM unit reboots, it will analyze the hash file and upgrade the firmware, configuration, or other files if required. If you have trouble with the TFTP upgrade process, please verify that the hash file and the other files are accessible using TFTP. The Structure of the Hash File The hash file is an ASCII configuration file with one line per entry. Each entry defines one upgrade action. There are 3 actions defined: 1. Upgrade firmware 2. Upgrade configuration 3. Upgrade any file 4. Execute an application. The action is the first entry in the line and it also defines the syntax of the line. Syntax for action 1: firmware upgrade <image name>,<model name>,<version> <image name>. specifying the path and the filename of the firmware on the TFTP server <model name>. specifying the product name especially the port count e.g. DigiCM48, DigiCM32, DigiCM16 or DigiCM8 This allows you to have one hash file for different models. <version>. the version number of the firmware The Digi CM unit will download the firmware if the version number of the running firmware is different than the firmware version in the hash file (the current firmware version is saved in file /tmp/cnf/version). Note: Make sure the firmware version in the hash file matches the firmware version on the FTP directory, otherwise you will start a continuous upgrade process. Example: cm48.img,digicm48,v Chapter 16

149 System Administration After the firmware was upgraded the Digi CM unit boots again. Syntax for action 2: configuration upgrade <image name>,<model name>,<version> <image name>. specifying the path and the filename of the configuration file on the TFTP server <model name>. specifying the product name especially the port count e.g. DigiCM48, DigiCM32, DigiCM16 or DigiCM8 This allows you to have one hash file for different models. <version>. the version number of the firmware The Digi CM unit will download the configuration if the version in the hash file is different from the version saved in the file /tmp/cnf/.cnfversion. This file does not exist until you do the first automatic configuration upgrade. It is also deleted if the unit is reset to factory defaults. If the /tmp/cnf/.cnfversion file does not exist, no download will occur. The file /tmp/cnf/.cnfversion is a hidden file. Example: config.tar.gz,digicm48,v After the firmware configuration is upgraded the Digi CM unit boots again. A sample hash file can be downloaded from: Syntax for action 3: file upgrade <file name>,<options>,<destination> <file name>. specifying the path and the filename of the file on the TFTP server <options>. - F: forced copy (override existing file) - X: decompress - Z: unzip - U: default option for file uploading <destination>. directory on the Digi CM unit to place the file These files are downloaded every time the Digi CM unit boots and there is no reboot after downloading. Example: snmpd.conf,fu,/tmp/cnf. The file snmpd.conf is copied from the TFTP server and placed into /tmp/cnf. The file is used as is and the previous version is overwritten. Syntax for action 4: execute a command <command> <parameters> <command>. any application resigin on the Digi CM unit that is executalbe by root <parameter>. all parameters this application requires Example: touch /tmp/test Chapter

150 Resetting Factory Defaults Resetting Factory Defaults There are two ways to reset the unit to the factory defaults. The quickest and simplest method is to push and hold the hardware factory default reset button until the Ready light on the front panel goes out. The reset button is located on the back panel of the unit next to the Ethernet port. The arrow points to the reset button s location. Factory reset button Digi CM 32 shown The alternative method to reset the unit is through the web interface. The web interface provides the option of retaining the IP settings. To use the web interface to reset the Digi CM unit, do the following: 1. Access the web interface. 2. System administration > Configuration management 3. Under Configuration import select Factory default.. 4. Select the Configuration factory default options you want to restore from the checklist. 5. Click Import. The Digi CM unit will automatically reboot. The following are the default values when the Digi CM unit is reset to the factory defaults. Static IP Address: Port Access Menu IP Address: Port Access Menu TCP Port Number: Chapter 16

151 System Administration Serial Port IP Address: Serial Port TCP Port Number: Setting Date and Time The Digi CM unit provides two options for keeping system time. The first is by using an NTP server and the other is through an internal battery backup. To configure the Digi CM unit for date and time, do the following: 1. Access the web interface. 2. System administration > Date and time. 3. To use an NTP server, choose Enable, the NTP server s IP address, the Time offset, and the Date and Time fields. or To use the internal battery, fill in the Date and Time fields only. Note: If you change your time zone, you must go back and reconfigure your time for the time zone change to be effective. 4. Choose Save & apply. Configuring a Host Name The system administrator can assign a Host name to the Digi CM unit. This is often helpful for administration purposes to locate a specific Digi CM unit on the network. To assign the Digi CM unit a device name, do the following: 1. Access the web interface. Chapter

152 Configuring a Host Name 2. System administration > Device name. 3. Enter the name you want to assign the Digi CM unit. 4. Choose Save & apply. 152 Chapter 16

153 Command Line Interface Chapter 17 Command Line Interface Introduction The Digi CM unit runs the embedded Hard Hat Linux operating system. The command line interface for configuration purposes is accessible only by the root user. The system administrator has read only privileges from the command line. By default the root user is connected to the CLI (command line interface) when accessing the Digi CM unit through Telnet or SSH. To gain access to the command prompt, the root user uses the username root and the root password. The default root password is dbps. This chapter includes the Linux commands available on the embedded Linux operating system and the location of files useful to the root user for administrative purposes. Note: The root user should be aware that deleting or corrupting files may prevent the Digi CM unit from booting properly. Before editing any files, be sure to back up your configuration files. Linux Commands The purpose of this section is to list the various Linux commands available on the Digi CM unit. This is simply a listing of commands and does not detail what the commands do or give their particular parameters. If you need more information, see the man pages on a Linux system. Two commands that are very important for saving and applying changes to the configuration files are: saveconf: The saveconf command saves the configuration files to flash memory. applyconf: The applyconf command immediately applies the configuration changes. The configuration files are located in /tmp/cnf directory. Two system utility menus that are important for accessing and configuring the Digi CM unit and the serial ports are the portaccessmenu and configmenu. portaccessmenu: This menu allows the user to access the serial ports on the Digi CM unit. configmenu: This menu enables the system administrator to configure the Digi CM unit. It has essentially the same functionality as the web interface for configuring a unit with the exception of the ability to create custom menus. portreset #: This command allows the user to reset a specific port. It restarts all processes associated with the port. Chapter

154 Important File Locations Shell and Shell Utilities sh ash bash echo sed env false grep more which pwd File and Disk Utilities ls cp mv rm mkdir rmdir ln mknod chmod touch sync gunzip gzip zcat tar dd df du find cat vi tail mkdosfs mke2fs e2fsck fsck mount umount scp System Utilities date free hostname sleep stty uname reset insmod rmmod lsmod modprobe kill killall ps half shutdown poweroff reboot telnet init useradd userdel usermod whoami who id su Network Utilities ifconfig iptables route telnet ftp ssh ping Important File Locations The Digi CM unit has several files that are important for administrative use. Below is a brief listing of some files that the root user or system administrator might desire to either monitor or edit. Default Script The default script file is executed whenever the Digi CM unit is booted. The file is /usr2/rc.user and can be modified with the vi editor. The modified script becomes effective when the system is rebooted. Booting Sequence When the Digi CM unit boots, it decompresses the /cnf/cnf.tar.gz file to /tmp/ cnf/* and unmounts the /cnf file. If the configuration files are modified in the / tmp/cnf file and the configuration is saved to flash (saveconf), the unit mounts the /cnf file and compresses the /tmp/cnf/* to /cnf/cnf.tar.gz. 154 Chapter 17

155 Command Line Interface Config Files All config files are in /tmp/cnf and /tmp/cnf subdirectories. The following table lists the filenames and a brief description. File Name active_detect chap-secrets client.pem./cluster/cluster.conf./cluster/unit#.conf.cnfversion dhcpd.opt ez-ipupdate.conf group host.cnf hosts interfaces krb5.conf./keywords./menu pap-secrets passive.detect passwd./power/power.cnf pppoe.conf redirect.cnf resolv.conf server.pem shadow snmpd.conf./.ssh Description Active auto detection of serial devices Chap authentication information when using PPPoE Web certificate Cluster Master port information Cluster Slave port information Version of current configuration. Used for TFTP update only DHCPD information Dynamic DNS information for IP assigning User group information Host name look up order Host name table Basic loopback (lo) and ethernet interface (eth0) information (IP, gateway, etc.) Kerberos information Keywords for alert configuration All custom menu information,.xml files PAP auth via PPPoE Passive auto detection of serial devices User password file Power management configuration Config file for PPPoE Basic port and portaccessmenu config information DNS information Private key for SSH with key certification information Secure password file SNMP information Directory for SSH information Chapter

156 Example Scripts File Name system.cnf timezone./.usracctl Description Basic network config information (IP, gateway, etc.) Time zone configuration Directory containing user access control information version User Storage Space The Digi CM unit comes with 1 megabyte of user storage space. This storage space can be used to store custom scripts. The location is /usr2. Custom scripts such as simple commands, are simply dropped into /usr2. If a file needs to be edited, copy the file into usr2/rc.usr, kill the process, then restart the process from the new file. Scripts from the user storage may be created to run during boot after the network is up. The following are some examples of various ways to create a script stored in the user storage space. Saving IP tables options permanently Changing radius socket ports Limiting root access to the console on Digi CM products Sending a break Example Scripts Example Script: -Saving IP tables options permanently Add the following command in the '/usr2/rc.user' script file just above "exit 0". Disabling Telnet is just shown as one example. 1. Create a new script file '/usr2/run.user' that includes the commands you want. iptables -A INPUT -p tcp --dport 23 -j DROP 2. Run the following command to make the script executable chmod 755 /usr2/run.user 3. Add the following command in the '/usr2/rc.user' script, just above "exit 0" ln -s /usr2/run.user /etc/rc.d/rc2.d/s60runuser 4. Reboot reboot Note: If you factory default the unit, the '/usr2/rc.user' script file is moved to '/usr2/ rc.user.old#' and the default rc.user file will be restored. Example Script: -Changing radius socket ports The radius client obtains the radius socket ports to use via the '/etc/services' file. The client only looks up the lines starting with 'radius' and 'radacct'. 1. Modify the /etc/services file as follows. Change lines starting with 'radius' and 'radacct' to the socket numbers you wish. For example: radius 1645/tcp radius 1645/ucp radacct 1646/tcp radacct 1646/ucp Firmware version 156 Chapter 17

157 Command Line Interface 2. After editing /etc/services copy it to /usr2 cp /etc/services /usr2 3. Edit /usr2/rc.user and add the following line just above "exit 0": cp -a /usr2/services /etc/services 4. Reboot reboot Note: If you factory default the unit, the '/usr2/rc.user' script file is moved to '/usr2/ rc.user.old#' and the default rc.user file will be restored. Example Script: -Limiting root access to the console on Digi CM products (for SSH only) This prevents root access from any means except physically logging in on the Digi CM console. 1. Modify '/etc/inetd.conf' and append -f /usr2/sshd_config to the sshd line. cp /etc/inetd.conf /usr2/inetd.conf 2. Edit '/etc/ssh/sshd_config'. Change "PermitRootLogin" to no. cp /etc/ssh/sshd_config /usr2 3. Add the following commands in the '/usr2/rc.user' script. Add these commands just above "exit 0": cp -a /usr2/inetd.conf /etc/inetd.conf while killall inetd 2>/dev/null; do sleep 5; done /usr/sbin/inetd 4. Reboot reboot Note: If you factory default the unit, the '/usr2/rc.user' script file is moved to '/usr2/ rc.user.old#' and the default rc.user file will be restored. Example Script: -Sending a break from an existing session with the Digi CM unit from a Telnet session If the Telnet was initiated from a UNIX command line Telnet client. Issuing the Telnet escape sequence '^]' (control-right_square_bracket) will take you to the 'telnet>' prompt. telnet>send brk Note: Other Telnet clients often have a "send break" option. From an ssh session - Type the [tilde-break] which is the default ssh break characters. ~break The ssh break can changed from the Web UI or config menu under Serial ports > Configuration > Host mode configuration > SSH break sequence Chapter

158 User Administration Additional binaries or applications can be added to /usr2 such as: crontab netstat fuser To download these utilities go to: User Administration Add, edit or delete users with the Digi CM unit s command line interface. Add user Example: useradd -d /tmp [-g groupid] [-s shellprogram] [username] groupid = Options are: Sys admin, Port admin, or Standard User. 500 = Sys admin 501 = Port admin 502 = Standard User These are the three types of groups supported by the Digi CM unit. You must use one of these. shellprogram = Options are: CLI (Command Line Interface), Config menu, Port access menu, or Custom menu. /bin/bash = CLI /bin/editconf = Configuration menu /bin/vts.master = Port access menu /bin/menu = Custom menu These are the four types of shells supported by the Digi CM unit. You must use one of these four. passwd [username] saveconf applyconf Modify user Example: usermod -d /tmp [-g groupid] [-s shellprogram] [username] Syntax is the same as it is for useradd mentioned above. saveconf applyconf Delete user Example: userdel[username] saveconf applyconf 158 Chapter 17

159 Command Line Interface Locator LED Script The Find Me LED on the Digi CM 48 can be deactivated and reactivated with the following file and command. Note: All other Digi CM units have the locator feature without a Find Me LED. To identify another Digi CM unit, all the LEDs blink when the feature is activated. The file and syntax for the locator LED is /bin/blinkled [start stop] Example to stop and start locator LEDS - root@mankato:~# /bin/blinkleds stop root@mankato:~# /bin/blinkleds start Chapter

160

161 Configuration Menu Chapter 18 Configuration Menu Introduction to the Configuration Menu The configuration menu presents the same functionality in configuring the Digi CM unit as does the web interface, excluding the creation of custom menus. The configuration menu is navigated by using the number representing the menu item and the ESC key to return to earlier menus. Telnet to the Digi CM unit, log in (username root, password dbps) and enter configmenu to start any configuration. If you log in as admin, the configuration menu will automatically appear. Accessing the Configuration Menu The configuration menu is available through a Telnet or SSH session to the root user, system administrator, or port administrator. (Port administrator can only change serial port parameters.) The configuration menu enables the authorized users to configure the Digi CM unit with the same functionality as is available with the web interface. The only functionality missing from the configuration menu is the ability to create custom menus. 1. Telnet into the Digi CM unit. The root user, by default, is connected from a Telnet session to the Linux command line. 2. Enter configmenu at the command prompt. The configuration menu follows the layout of the web interface. Choices for the configuration menu are made by selecting the number of a menu item. The ESC key allows you to move back a menu each time it is Chapter

162 Configuring SSH selected. Sometimes only one menu item is presented; however, that single menu item has two or more options that have to be configured. Configuring SSH 1. Choose Serial Port Configuration and then an individual port number or 0 (zero) for all ports. The Save changes option saves changes to flash memory only. 2. Choose Host mode configuration > Protocol > SSH. Choose Exit and apply changes when you have made all your changes. 3. Use the ESC key to return to the main configuration menu. 4. Choose Exit and apply changes. 162 Chapter 18

163 Configuration Menu Adding, Editing, and Removing Users 1. Choose System administration > User administration and then choose an operation to perform (Add, Remove, or Edit) 2. Configure the user as required. 3. Use the ESC key to return to the main configuration menu. 4. Choose Exit and apply changes. Adding and Configuring a PC Card To add a modem card, compact-flash card, wireless LAN card, or a network card to the Digi CM unit using the configuration menu, do the following: 1. Access the configuration menu. 2. Choose PC Card configuration 3. Configure the card by choosing Change card configuration. Note: The system searches for the card and displays information on the product model number and type of card. 4. Use the ESC key to back out to the main configuration menu. 5. Choose Save Changes. Host Mode Configuration 1. Access the configuration menu. Chapter

164 Port Parameters 2. Choose Serial Port Configuration > an individual port number or 0 (zero) for all ports > Host Mode Configuration. 3. Enter the desired parameters for each menu item. 4. Use the ESC key when all parameters are entered to return to the main menu. 5. Choose Save changes. Port Parameters 1. Access the configuration menu. 2. Choose Serial Port Configuration > an individual port number or 0 (zero) for all ports. 3. Enter the desired parameters for each menu item. 4. Use the ESC key when all parameters are entered to return to the main menu. 5. Choose Save changes. Port Access Menu Another default menu is the Port Access Menu, which is available to all users. 1. Access Configuration menu 2. Select Serial Port Configuration. 3. Select 0 for all ports. 4. Select Port access menu configuration. 164 Chapter 18

165 Configuration Menu You can access this menu through a Telnet or SSH session using the IP address of the Digi CM unit followed by the port number 7000 as in the following example: telnet By default root is connected to the command line interface and the preceding option allows the root user access to the port access menu. System Logging System logging is a two part process. First, the device being used to record the system logs must be configured. Secondly, system logging must be configured for the system under System status and log. System logs can be saved to the Digi CM unit s system memory (there is no need to configure the memory), a compact-flash card, an NFS server, or a SYSLOG server. Configure the System Log Device To configure the compact-flash card for system logging, see "Adding a Compact-flash Card" on page 31. Adding a Compact-flash Card For an NFS or SYSLOG server, do the following: 1. Access the configuration menu. 2. Choose Network configuration > NFS or SYSLOG server configuration. Chapter

166 Configuring SNMP 3. Disable or enable the server. 4. Use the ESC key when all parameters are entered to return to the main menu. 5. Choose Save changes. Configure System Logging 1. Access the configuration menu. 2. Choose System Status & log > System logging. Configuring SNMP 3. Enter the desired parameters for the menu items. 4. Use the ESC key when all parameters are entered to return to the main menu. 5. Choose Save changes. To configure SNMP from the configuration menu, do the following: 1. Access the configuration menu. 2. Choose Network Configuration > SNMP configuration. 3. Enter the desired parameters for the menu items. 4. Use the ESC key when all parameters are entered to return to the main menu. 5. Choose Save changes. Configuring SMTP To configure SMTP from the configuration menu, do the following: 166 Chapter 18

167 Configuration Menu 1. Access the configuration menu. 2. Choose Network configuration > SMTP configuration. 3. Enter the desired parameters for the menu items. 4. Use the ESC key when all parameters are entered to return to the main menu. 5. Choose Save changes. Network IP Filtering To configure the Digi CM unit for Network IP filtering, do the following: 1. Access the configuration menu. 2. Choose Network configuration > IP filtering. s 3. Choose a menu item and enter the desired parameters for the menu items. Chapter

168 Port IP Filtering 4. Use the ESC key to return to the main menu. 5. Choose Save changes. Port IP Filtering To configure the Digi CM unit for Port IP filtering, do the following: 1. Access the configuration menu. 2. Choose Serial port configuration. 3. Choose an individual port number or 0 (zero) for all ports > IP filtering. 4. Choose a menu item and enter the desired parameters for the menu items. 5. Use the ESC key when all parameters are entered to return to the main menu. 6. Choose Save changes. Sniff Sessions To configure a port or all ports for sniff users, do the following: 1. Access the configuration menu. 2. Choose Serial port configuration. 3. Choose an individual port number or 0 (zero) for all ports > User access control. 4. Choose User Access Control. 5. Choose Enable/Disable Sniff Mode. 168 Chapter 18

169 Configuration Menu 6. Choose a menu item and enter the desired parameters. 7. Use the ESC key when all parameters are entered to return to the main menu. 8. Choose Save changes. For information on entering a sniff session, see the next section, "Viewing A Sniff Session" on page 169. Viewing A Sniff Session A sniff user enters a sniff session by starting a Telnet session on a specified port. In the following example, a sniff user telnets to port 7 of the Digi CM unit. From the command prompt enter the following command: telnet Log in and enter your password 2. Enter the port escape sequence. When sniff users login to a port from a Telnet session, a sniff session menu is Chapter

170 Sniff Sessions displayed with your permitted options. The first user (with port access rights) to login to the port is in the main session. The next user (with port access rights) to enter the port will be given the option to take over the main session. This user is given the option to take over the main session by either terminating the first user or switching the first user to sniff (read only). Field Descriptions for Sniff Sessions Escape Sequence Ctrl+ m s Description of Action take over main session (read/write) enter as a slave session (read only) Occurrence only presented to users with read/write access upon entering a session only presented to users with read/write access upon entering a session b send break not functional for sniff users l show last 100 lines of log buffer must enable logging for this option d disconnect a sniff session only functional to admin a send message to port user(s) not available to sniff users r p reboot device using power-switch power device on/off only if power management is available on this port (show only on or off) only if power management is available on this port 170 Chapter 18

171 Configuration Menu Escape Sequence Ctrl+ x Description of Action close current connection to port Occurrence closes the sniff session connection Authentication 1. Access the configuration menu. 2. Choose Serial port configuration. 3. Choose an individual port number or 0 (zero) for all ports > Authentication. 4. Choose Authentication type. Upload Server Certificate 5. Use the ESC key to return to the main menu. 6. Choose Save changes. To upload your own certificate, you can use one of following two methods, 1. Use Upload Server Certificate menu. But please note that this menu is displayed only when you run configmenu on the serial console of the Digi CM unit. (configmenu run on CLI via Telnet Chapter

172 Upload Server Certificate or SHI will not display this menu) 2. Copy your own server.pem file to /tmp/cnf/ using scp. Please don't forget to run saveconf command in CLI if you want to keep this change permanently. You can use your own certificate for your Digi CM unit after replacing the original server.pem on /tmp/cnf/ with your server.pem. The following procedure is to import an SSL certificate for the HTTPS interface. OpenSSL(SSLeay) Simple CA Usage - Install Openssl 1. Download latest openssl package 2. Install openssl package # cd /work/ # tar -xvzf openssl-0.9.7c.tar.gz # cd openssl-0.9.7c #./config # make # make test # make install Make Root CA (Certificate Authority for Self-signed) 1. Edit openssl configuration file Note: # vi /usr/share/ssl/openssl.cnf Modify [req_distinguished_name] section of "openssl.cnf" Please refer to sample openssl.conf file(openssl.conf.digi). Modify [req_attributes] section of "openssl.cnf" challengepassword_min =0 challengepassword_max =0 2. Make self-signed Root CA(Certificate Authority) # cd /work/openssl-0.9.7c/ # mkdir CA # cd CA # sh /usr/local/ssl/misc/ca.sh -newca CA certificate filename (or enter to create) ; (Press Enter to use default value) Making CA certificate... ; openssl is called here as follow from CA.sh ; openssl req -new -x509 -keyout./democa/private/./cakey.pem \ ; -out./democa/./cacert.pem -days Use configuration from /usr/local/ssl/lib/ssleay.cnf 4. Generate a 1024 bit RSA private key Chapter 18

173 5. Write new private key to './democa/private/./cakey.pem' 6. Enter PEM pass phrase: ; CA Password (Enter passsword and remember this) Verify password - Enter PEM pass phrase: ; CA Password Note: The following information will be incorporated into your certificate. Configuration Menu You will enter text for a field call Distinguished Name or a DN. Although there are many fields, some can be left blank, use a default, or enter. and the field will be left blank ; CA's Information Country Name (2 letter code) [AU]: US State or Province Name (full name) [Your-State]: Minnesota Locality Name (eg, city) []: Minneapolis Organization Name (eg, company): Digi International Organizational Unit Name (eg, section) [](Enter) Common Name (eg, YOUR name) []: Bob Alou Address []:(Enter) # 7. Verify the CA key file(democa/private/cakey.pem) and CA certificate (democa/cacert.pem) is generated # ls democa/ cacert.pem certs crl index.txt newcerts private serial # ls democa/private cakey.pem Making a Certificate Request To make new certificates, you should make a certificate request first. 1. Enter the following # cd /work/openssl-0.9.7c/ca 2. Run the following commands: # openssl genrsa -out key.pem 1024 # openssl req -new -key key.pem -out req.pem It is assumed that you are using sample configuration file - "openssl.conf.digi" ) 3. Use configuration from /usr/share/ssl/openssl.cnf You are about to be asked to enter information that will be incorporated into your certificate request. What you are about to enter is what is called a Distinguished Name or a DN. There are quite a few fields but you can leave some blank For some fields there will be a default value, If you enter '.', the field will be left blank Note: The following information will be incorporated into your certificate. Chapter

174 Upload Server Certificate You will enter text for a field call Distinguished Name or a DN. You may enter a default or. to leave the field blank ; CA's Information Country Name (2 letter code) [AU]: US State or Province Name (full name) [Your-State]: Minnesota Locality Name (eg, city) []: Minneapolis Organization Name (eg, company): Digi International Organizational Unit Name (eg, section) [](Enter) Common Name (eg, YOUR name or your server s hostname) []: Digi CM Address []:(Enter) Enter the following 'extra' attributes to be sent with your certificate request A challenge password []:(Press Enter - Do not enter any other characters) An optional company name []:(Press Enter - Do not enter any other characters) Signing a Certificate Request 1. To sign a certificate request, enter the following: # cd /work/openssl-0.9.7c/ca # cp req.pem newreq.pem # sh /usr/local/ssl/misc/ca.sh -sign Use configuration from /usr/share/ssl/openssl.cnf 2. Enter PEM pass phrase: CA Password (Enter CA Password from "Make Root CA (Certificate Authority for Self-signed)" on page Check that the request matches the signature Signature ok The Subjects Distinguished Name is as follows countryname :PRINTABLE:'US' stateorprovincename :PRINTABLE:'Minnesota' localityname :PRINTABLE:'Minneapolis' organizationname :PRINTABLE:'Digi International' commonname :PRINTABLE:'Digi CM' Certificate is to be certified until Oct 6 09:39: GMT (3653 days) Sign the certificate? [y/n]:y 1 out of 1 certificate requests certified, commit? [y/n]y Write out database with 1 new entries Data Base Updated Certificate: Data: Version: 3 (0x2) Serial Number: 1 (0x1) Signature Algorithm: md5withrsaencryption Issuer: C=US, ST=Minnesota, L=Minneapolis, O=Digi International, CN=Digi International Validity Not Before: Oct 6 09:39: GMT Not After : Oct 6 09:39: GMT 174 Chapter 18

175 Configuration Menu Subject: C=US, ST=Minnesota, L=Minneapolis, O=Digi International, CN=Digi CM Subject Public Key Info: Public Key Algorithm: rsaencryption RSA Public Key: (1024 bit) BEGIN CERTIFICATE END CERTIFICATE----- Signed certificate is in newcert.pem 4. Verify signed certificate(newcert.pem) is generated. # ls democa key.pem newcert.pem newreq.pem req.pem Make Certificate for the Digi CM Unit 1. Removing headings in newcert.pem file # cd /work/openssl-0.9.7c/ca # cp newcert.pem server.pem # vi server.pem Certificate: Data: Version: 3 (0x2) Serial Number: 1 (0x1) Signature Algorithm: md5withrsaencryption Issuer: C=US, ST=Minnesota, L=Minneapolis, O=Digi International, CN=Digi CM Validity Not Before: Oct 6 09:39: GMT Not After : Oct 6 09:39: GMT Subject: C=US, ST=Minnesota, L=Minneapolis, O=Digi International, CN=Digi CM Subject Public Key Info: Public Key Algorithm: rsaencryption RSA Public Key: (1024 bit)... == Removing above lines === -----BEGIN CERTIFICATE END CERTIFICATE Concatenating key.pem file to server.pem # cat key.pem >> server.pem Dial-in Modem Access Individual serial ports on the Digi CM unit can be configured for dial-in modem access. To use dial-in modem mode, an external modem is first attached to a serial port and then the serial port is configured for dial-in modem access. In the illustration below, port 7 is configured for a dial-in modem. Chapter

176 Dial-in Terminal Server Access To configure a serial port for a dial-in modem, do the following: 1. Access the configuration menu. 2. Choose Serial Port Configuration. 3. Choose an individual port number and then Host Mode Configuration. 4. Select Host mode and then Dial-in modem. 5. Use the ESC key to return to the main menu. 6. Choose Save changes. Dial-in Terminal Server Access Individual serial ports on the Digi CM unit can be configured for a dial-in terminal server access. To use dial-in terminal server access, an external modem is first attached to a serial port on the Digi CM unit and then the serial port is configured for dial-in terminal server mode. In the illustration below, port 7 is configured for dial-in terminal server mode. In terminal server mode, you are connected directly to a server. To configure a serial port for a dial-in terminal server, do the following: 1. Access the configuration menu. 2. Choose Serial port configuration. 3. Choose an individual port number and then Host Mode Configuration. 176 Chapter 18

177 Configuration Menu 4. Choose Dial-in Terminal Server and configure the other configuration parameters. 5. Use the ESC key to return to the main menu. 6. Choose Save changes. Clustering By default clustered slave devices are configured using the Telnet protocol and port parameters of the following: bps=9600, data bits=8, parity=none, stop bits=1, flow control=none. When the master device autoconfigures a slave device, it simply imports the information from the slave unit. If you want other protocols or other port parameters, you should configure your slave unit first with those parameters before autoconfiguring. Before you start this configuration procedure, the slave units should already be configured unless you want them set to the default values. To set up the Digi CM unit for clustering, do the following: 1. Access the configuration menu. 2. Choose Clustering configuration > Unit position. 3. Assign the unit as the master device. A new screen is displayed. 4. Enter the number 1 for the first slave unit. 5. Choose Enable/Disable unit clustering > Enable. 6. Enter the values for Slave Unit IP, No. of ports, and Port configuration. Chapter

178 Firmware Upgrade 7. Select the port number to configure or 0 for all ports. 8. Select Enable configuration 9. Select Auto Configuration 10. Choose Exit and apply changes. Firmware Upgrade Before upgrading firmware from the configuration menu you should have: Downloaded the firmware to a system on the same subnet Set up a terminal emulation program that supports Zmodem transfer protocol To upgrade the firmware with the configuration menu, do the following: 1. Access the configuration menu. 2. Choose System administration. 3. Choose Firmware upgrade. Enter y for Yes when asked if you want to upgrade the firmware. If the firmware upgrade is successful, the Digi CM unit will reboot automatically. If a Firmware upgrade failed! Warning appears, do not reboot the unit but repeat the upgrade process. 178 Chapter 18

179 Configuration Menu Restoring Factory Defaults You have two choices to restore the unit to its factory defaults. The options are restoring all factory defaults or restoring all factory defaults except IP settings. To restore your unit to the factory defaults, do the following: 1. Access the configuration menu. 2. Choose System administration. 3. Select Configuration import. 4. Select Location 5. Select Factory Default. The system will restore factory defaults, and the unit will automatically reboot. Note: Use System Administration to save your configuration in case you need to reload it later or onto another system. See "Adding and Configuring a PC Card" on page 163 for more information. Setting Date and Time Date and time on the Digi CM unit can either be kept internally or by an NTP server. To set the parameters for date and time on the Digi CM unit, do the following: 1. Access the configuration menu. 2. Choose System administration. 3. Choose Date and Time. 4. Enter the desired parameters. 5. Choose Save changes. Accessing the Boot Loader Program The Boot Loader program can be accessed during the boot process. The main function of the program is to provide a backup means for restoring the firmware if the Digi CM unit will no longer boot. It also provides a hardware Chapter

180 Accessing the Boot Loader Program testing module that detects and tests hardware components on the unit. To access the Boot Loader program, do the following: 1. Connect the Ethernet cable from the console port on the rear panel of the Digi CM unit to a serial port on a workstation. Use the Ethernet cable packaged with the Digi CM unit and attach the DB-9 adapter. The arrow in the following graphic points to the Console Port. Console Port back of Digi CM 32 shown 2. Set up a terminal emulation program, such as HyperTerminal, using the following port parameters: bps=9600, data bits=8, parity=none, stop bits=1, and flow control=none. 3. Turn the power on to the unit. 4. Press ESC within 3 seconds of booting the unit to get Boot Loader menu. Hardware Test Menu The Boot Loader program provides a hardware test for detecting and testing hardware components on the Digi CM unit. From the Boot Loader menu, choose the number 3 to access the Hardware test. Options for several components appear. Disaster Recovery The Digi CM unit provides a disaster recovery procedure in the event the configuration data is destroyed or corrupted. The Digi CM unit automatically restores a corrupted configuration file system to the factory default settings. However, if the Digi CM unit fails to boot in spite of being reset to the factory default settings, the firmware can be restored by using the Boot Loader program. To restore the Digi CM unit to the factory default configuration settings, you will need to use a TFTP or BOOTP server. To use the Boot Loader program to flash new firmware, do the following: 1. Connect the console port on the rear panel of the Digi CM unit to a serial port on a workstation. Use an Ethernet cable with a DB-9 adapter. 2. Set up a terminal emulation program such as HyperTerminal. Use the following port parameters: bps=9600, data bits=8, parity=none, stop bits=1, flow control=none 3. Reboot or power on the Digi CM unit. 4. Press the ESC key within three seconds of applying power to the device. The following screen appears. 180 Chapter 18

181 Use the ESC key to return to an earlier menu screen. 5. Choose Firmware upgrade by entering 3. The following screen appears. 6. Enter the information for the first menu items. Protocol: The choices are BOOTP or TFTP IP address assigned: Enter the IP address of the Digi CM unit Server s IP address: The IP address of the BOOTP or TFTP server Firmware File Name: The filename for the firmware Note: Use the ESC key to back up to earlier menu screens. 7. Choose Start firmware upgrade. The firmware upgrade will take several minutes to process. This will factory default the unit. 8. When the upgrade process is complete, choose ESC to return to the main menu. 9. Choose Exit and boot from flash.

182

183 Hardware Information Chapter 19 Introduction Hardware Information This chapter provides information on Digi CM hardware. Among the topics covered are the hardware specifications, LED descriptions, pinouts for the Ethernet cable, pinouts for the cable adapters, and rack mounting specifications. Hardware Specifications Digi CM 48 Attribute Hardware Specifications Value AC Powered Value DC Powered Operating temperature 40 F to 120 F (5 C to 50 C) 40 F to 120 F (5 C to 50 C) Storage temperature -20 F to 140 F (-29 C to 60 C) -20 F to 140 F (-29 C to 60 C) Humidity 10% to 90% non-condensing 10% to 90% non-condensing Power supply Power consumption Internal, VAC, 50/60 Hz, 1.2A (max) 0.37A /120VAC, 45W (typical), 150W (max) Internal, Vdc, 1.2A (max) 0.4A /48Vdc, 19W (typical), 40W (max) Fuse (internal) FUSE (Type L) AC250V, 2A Fuse (Type L) 250V, 5A Operating system Linux Hard Hat embedded Linux Hard Hat embedded SDRAM 256 megabytes 256 megabytes Flash memory 16 megabytes 16 megabytes Dimensions: unpackaged Dimensions: packaged 17.5 x 10.0 x 1.75 (44.5 x 25.4 x 4.5 cm) x x 4.75 (517.5 mm mm x mm) 17.5 x 10.0 x 1.75 (44.5 x 25.4 x 4.5 cm) x x 4.75 (517.5 mm mm x mm) Weight: unpackaged Weight: packaged 6.5 lbs (2.95 kg) 6.7 lbs (3.05 kg) 9.95 lbs (4.51 kg) 10.2 lbs (4.61 kg) Chapter

184 Hardware Specifications Digi CM 16 and Digi CM 32 Attribute AC Powered Value DC Powered Value Operating temperature 40 F to 120 F (5 C to 50 C) 40 F to 120 F (5 C to 50 C) Storage temperature -20 F to 140 F (-29 C to 60 C) -20 F to 140 F (-29 C to 60 C) Humidity 10% to 90% non-condensing 10% to 90% non-condensing Power supply Power consumption Fuse (internal) Operating system Internal, VAC, 50/60 Hz, 1.2A (max) 0.1A /120VAC (type), 12W (typical), 40W (max) FUSE (Type L) AC250V, 2A Linux Hard Hat embedded Internal, Vdc, 1.2A (max) 0.25A /48Vdc, 12W (typical), 40W (max) Linux Hard Hat embedded SDRAM 64 megabytes 64 megabytes Flash memory 8 megabytes 8 megabytes Dimensions: unpackaged Dimensions: packaged 17 x 8.5 x 1.75 (431.8 cm x cm x 44.5 cm) x x 4.75 (517.5 cm cm x cm) 17 x 8.5 x 1.75 (431.8 cm x cm x 44.5 cm) x x 4.75 (517.5 cm cm x cm) Weight: unpackaged Weight: packaged 5.8 lbs (2.63 kilograms) 5.8 lbs (2.63 kilograms) 8.6 lbs (3.9 kilograms) 8.6 lbs (3.9 kilograms) Digi CM 8 AC Powered Attribute Operating temperature Storage temperature Humidity Power supply Power consumption Operating system SDRAM Flash memory Dimensions Weight 40 F to 120 F (5 C to 50 C) -20 F to 140 F (-29 C to 60 C) 10% to 90% non-condensing Value External, VAC, 50/60 Hz, 1.0A (max) AC input: 0.05A /120VAC, 6W (typical), 12W (max) DC input: 0.8A/5VAC, 4.5 W (typical), 8W (max) Linux Hard Hat embedded 64 megabytes 8 megabytes 9.5 x 6.25 x 1.25 (241.3 cm x cm) 2.5 lbs (1.13 kilograms) 184 Chapter 19

185 Hardware Information LED Indicators Use the LED indicators to confirm your attachment to the network and that the Digi CM unit is able to send and receive data. LED Power Function On when power is supplied System Ethernet Serial port* Ready PC 100Mbps LINK Act In use Rx/Tx On when system is ready to run On when a PC device is running On when 100Base-TX connection is detected On when connected to an Ethernet network Blinks when there is activity on the Ethernet port On when the serial port is ready to run Blinks when there is traffic on the serial port *Not available on the Digi CM 48 About Serial Port Cabling The Digi CM unit simplifies cabling. The RJ-45 8-pin configuration matches all SUN and Cisco RJ-45 console port configurations, enabling CAT 5 cabling without pinout concerns. Three DB-25 and one DB-9 adapters come in the package. A DB-25 male, a DB-25 female, and a DB-9 adapter support console management applications. A DB-25 male adapter provides a modem connection. See the cable adapter information that follows later in this chapter. Serial Port Pinouts Note: The cable length restrictions common to RS-232 cables apply to the Digi CM serial cable as well. The Digi CM unit uses an RJ-45 connector for serial ports. Pin assignments are listed in the following table. Pin Description 1 CTS 2 DSR 3 RxD 4 GND 5 DCD Note: Inbound signal can also be used as a second ground. 6 TxD 7 DTR 8 RTS Chapter

186 Cable Adapters Cable Adapters The Digi CM unit comes with four cable adapters. The following illustrations show cable adapter pin outs. Additional adapters can be purchased from Digi in quantities of 8. DB-25 Male Console Adapter (Digi 8-pack reorder P/N ) Pin #1 Pin #13 Pin #25 DB-25 Male to RJ-45 Connector Pin Assignments RJ-45 Signal DB-25M Signal 1 CTS Connected to 4 RTS 2 DSR 5 DCD Connected to 20 DTR 3 RxD Connected to 2 TxD 4 GND Connected to 7 GND 6 TxD Connected to 3 RxD 7 DTR Connected to 6 DCD 8 DSR 8 RTS Connected to 5 CTS 186 Chapter 19

187 Hardware Information DB-9 Female Console Adapter (Digi 8-pack reorder P/N ) Pin #5 Pin #1 Pin #1 Pin #6 DB-9 Female to RJ-45 Pin Assignments Pin #8 RJ-45 Signal DB-9F Signal 1 CTS Connected to 7 RTS 2 DSR 5 DCD Connected to 4 DTR 3 RxD Connected to 3 TxD 4 GND Connected to 5 GND 6 TxD Connected to 2 RxD 7 DTR Connected to 1 DCD 6 DSR 8 RTS Connected to 8 CTS Chapter

188 Cable Adapters DB-25 Female Console Adapter (Digi 8-pack reorder P/N ) Pin#13 Pin #1 Pin#25 DB-25 Female to RJ-45 Pin Assignments RJ-45 Signal DB-25M Signal 1 CTS Connected to 4 RTS 2 DSR 5 DCD Connected to 20 DTR 3 RxD Connected to 2 TxD 4 GND Connected to 7 GND 6 TxD Connected to 3 RxD 7 DTR Connected to 6 DCD 8 DSR 8 RTS Connected to 5 CTS 188 Chapter 19

189 Hardware Information DB-25 Male Modem Adapter (Digi 8-pack reorder P/N ) Pin #1 Pin #13 Pin #25 DB-25 Male Modem to RJ-45 Pin Assignment RJ-45 Signal DB-25M Signal 1 CTS Connected to 5 CTS 2 DSR Connected to 6 DSR 3 RxD Connected to 3 RxD 4 GND Connected to 7 GND 5 DCD Connected to 8 DCD 6 TxD Connected to 2 TxD 7 DTR Connected to 20 DTR 8 RTS Connected to 4 RTS Chapter

190 Ethernet Pinouts DB-9 Male Modem Adapter (Digi 8-pack reorder P/N ) (Available but not included) Pin #1 Pin #5 Pin #1 Pin #6 Pin #8 DB-9 Male Modem to RJ-45 Pin Assignment RJ-45 Signal DB-9M Signal 1 CTS Connected to 8 CTS 2 DSR Connected to 6 DSR 3 RxD Connected to 2 RxD 4 GND Connected to 5 GND 5 DCD Connected to 1 DCD 6 TxD Connected to 3 TxD 7 DTR Connected to 4 DTR 8 RTS Connected to 7 RTS Ethernet Pinouts The Digi CM unit uses a standard Ethernet connector, that is a shielded and compliant with AT&T 258 specifications. Pin Description 1 Tx+ 2 Tx- 3 Rx+ 4 NC 5 NC 6 Rx- 7 NC 8 NC 190 Chapter 19

191 Hardware Information Rack Mounting Installation Rack shown in illustration is not included with the Digi CM unit. 1. Attach enclosed bracket ears to rack as shown in illustration. 2. Follow safety precautions when placing the Digi CM unit on the rack. Rack Mounting Safety Precautions Distribute weight evenly in the rack to avoid overloading. Ensure proper ventilation with at least 12 inches (30 centimeters) of clearance on all sides. Check equipment nameplate ratings before connecting to the supply circuit to avoid overloads that may damage over-current protection devices and supply wiring. Maintain reliable earthing for rack-mounting equipment, especially for supply connections. Install equipment in Restricted Access Areas only (dedicated equipment rooms/closets) in accordance with Articles , , and of the National Electrical Code, ANSI/NFPA 70. Connect equipment to a DC supply source (reliably earthed) that is electrically isolated from the AC source. Directly connect the equipment chassis to the DC supply system-grounding electrode conductor or a bonding jumper from a grounding terminal bar (or bus) that is connected to the DC supply system grounding electrode conductor. Contain equipment that has a connection between the grounded conductor of the same DC supply circuit, the grounding conductor, and also the point of grounding of the DC system in the same immediate area. Do not ground the equipment elsewhere. Chapter

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset) Version: 1.4 Table of Contents Using Your Gigabyte Management Console... 3 Gigabyte Management Console Key Features and Functions...

More information

ZyWALL 5. Internet Security Appliance. Quick Start Guide Version 3.62 (XD.0) May 2004

ZyWALL 5. Internet Security Appliance. Quick Start Guide Version 3.62 (XD.0) May 2004 ZyWALL 5 Internet Security Appliance Quick Start Guide Version 3.62 (XD.0) May 2004 Introducing the ZyWALL The ZyWALL 5 is the ideal secure gateway for all data passing between the Internet and the LAN.

More information

3.5 EXTERNAL NETWORK HDD. User s Manual

3.5 EXTERNAL NETWORK HDD. User s Manual 3.5 EXTERNAL NETWORK HDD User s Manual Table of Content Before You Use Key Features H/W Installation Illustration of Product LED Definition NETWORK HDD Assembly Setup the Network HDD Home Disk Utility

More information

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005 Vantage RADIUS 50 Quick Start Guide Version 1.0 3/2005 1 Introducing Vantage RADIUS 50 The Vantage RADIUS (Remote Authentication Dial-In User Service) 50 (referred to in this guide as Vantage RADIUS)

More information

Addonics T E C H N O L O G I E S. NAS Adapter. Model: NASU2. 1.0 Key Features

Addonics T E C H N O L O G I E S. NAS Adapter. Model: NASU2. 1.0 Key Features 1.0 Key Features Addonics T E C H N O L O G I E S NAS Adapter Model: NASU2 User Manual Convert any USB 2.0 / 1.1 mass storage device into a Network Attached Storage device Great for adding Addonics Storage

More information

Connecting the DG-102S VoIP Gateway to your network

Connecting the DG-102S VoIP Gateway to your network Contents of Package: DG-102S VoIP Station Gateway Power adapter CD-ROM, including User s Manual Quick Install Guide Requirements: RS-232 Console Cable Two RJ-45 CAT-5 Straight-Through Cables For more information

More information

Release Notes for Dominion SX Firmware 3.1.6

Release Notes for Dominion SX Firmware 3.1.6 Release Notes for Dominion SX Firmware 3.1.6 Release Notes Version: 4.0 Release Notes Date: December 4, 2008 Effective: Immediately Applicability: The 3.1.6 Release is applicable to the Dominion SX. SX

More information

Chapter 4 Management. Viewing the Activity Log

Chapter 4 Management. Viewing the Activity Log Chapter 4 Management This chapter describes how to use the management features of your NETGEAR WG102 ProSafe 802.11g Wireless Access Point. To get to these features, connect to the WG102 as described in

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

SCS3205/4805 Quick Start Guide

SCS3205/4805 Quick Start Guide Secure Console Server Quick Start Guide 2003 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-287 Rev. B 8/03 QUICK START CONTENTS System Overview.......................................................2

More information

Chapter 6 Using Network Monitoring Tools

Chapter 6 Using Network Monitoring Tools Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under

More information

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business Quick Start Guide Cisco Small Business WRV210 Wireless-G VPN Router with RangeBooster Package Contents WRV210 Router Ethernet Cable Power Adapter Product CD-ROM Quick Start Guide Welcome Thank you for

More information

Chapter 3 Management. Remote Management

Chapter 3 Management. Remote Management Chapter 3 Management This chapter describes how to use the management features of your ProSafe 802.11a/g Dual Band Wireless Access Point WAG102. To access these features, connect to the WAG102 as described

More information

Environmental Monitoring Unit

Environmental Monitoring Unit Environmental Monitoring Unit AP9312TH AP9312THi User s Guide Contents Environmental Monitoring Unit Managing the Unit............................ 1 Introduction.................................. 1 Available

More information

Digi Passport User s Guide

Digi Passport User s Guide Digi Passport User s Guide 90000767_F Digi International Inc. 2013. All rights reserved. Digi, Digi International, the Digi logo, Digi Passport, Digi One, and RealPort are trademarks or registered trademarks

More information

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400 PePWave Surf Outdoor Series: Surf AP 200/400-X, PolePoint 400-X, Surf 400-DX User Manual Document Rev. 1.2 July 07 COPYRIGHT & TRADEMARKS

More information

Dominion KX II-101-V2

Dominion KX II-101-V2 Dominion KX II-101-V2 Quick Setup Guide Thank you for your purchase of the Dominion KX II-101-V2, the economical, full-featured, single-port digital KVM-over-IP device. For details on using the KX II-101-V2,

More information

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide Prestige 324 Intelligent Broadband Sharing Gateway Version 3.60 January 2003 Quick Start Guide 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100 Mbps

More information

Quadro Configuration Console User's Guide. Table of Contents. Table of Contents

Quadro Configuration Console User's Guide. Table of Contents. Table of Contents Epygi Technologies Table of Contents Table of Contents About This User s Guide... 3 Introducing the Quadro Configuration Console... 4 Technical Specification... 6 Requirements... 6 System Requirements...

More information

Pharos Control User Guide

Pharos Control User Guide Outdoor Wireless Solution Pharos Control User Guide REV1.0.0 1910011083 Contents Contents... I Chapter 1 Quick Start Guide... 1 1.1 Introduction... 1 1.2 Installation... 1 1.3 Before Login... 8 Chapter

More information

Chapter 6 Using Network Monitoring Tools

Chapter 6 Using Network Monitoring Tools Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items

More information

Gigabyte Content Management System Console User s Guide. Version: 0.1

Gigabyte Content Management System Console User s Guide. Version: 0.1 Gigabyte Content Management System Console User s Guide Version: 0.1 Table of Contents Using Your Gigabyte Content Management System Console... 2 Gigabyte Content Management System Key Features and Functions...

More information

Network-Enabled Devices, AOS v.5.x.x. Content and Purpose of This Guide...1 User Management...2 Types of user accounts2

Network-Enabled Devices, AOS v.5.x.x. Content and Purpose of This Guide...1 User Management...2 Types of user accounts2 Contents Introduction--1 Content and Purpose of This Guide...........................1 User Management.........................................2 Types of user accounts2 Security--3 Security Features.........................................3

More information

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem

c. Securely insert the Ethernet cable from your cable or DSL modem into the Internet port (B) on the WGT634U. Broadband modem Start Here Follow these instructions to set up your router. Verify That Basic Requirements Are Met Assure that the following requirements are met: You have your broadband Internet service settings handy.

More information

NMS300 Network Management System

NMS300 Network Management System NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate

More information

your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Configuring Installing

your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Configuring Installing your Gateway Windows network installationguide 802.11b wireless series Router model WBR-100 Installing Configuring Contents 1 Introduction...................................................... 1 Features...........................................................

More information

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev. Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of

More information

WEB CONFIGURATION. Configuring and monitoring your VIP-101T from web browser. PLANET VIP-101T Web Configuration Guide

WEB CONFIGURATION. Configuring and monitoring your VIP-101T from web browser. PLANET VIP-101T Web Configuration Guide WEB CONFIGURATION Configuring and monitoring your VIP-101T from web browser The VIP-101T integrates a web-based graphical user interface that can cover most configurations and machine status monitoring.

More information

Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5

Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5 Contents Network Management Card Wizard--1 Introduction....................................... 1 Using the Network Management Card Wizard................ 5 File Transfers--10 Introduction......................................

More information

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide Prestige 324 Intelligent Broadband Sharing Gateway Version V3.61(JF.0) May 2004 Quick Start Guide 1 1 Introducing the Prestige The Prestige is a broadband sharing gateway with a built-in four-port 10/100

More information

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,

More information

Broadband Router ESG-103. User s Guide

Broadband Router ESG-103. User s Guide Broadband Router ESG-103 User s Guide FCC Warning This equipment has been tested and found to comply with the limits for Class A & Class B digital device, pursuant to Part 15 of the FCC rules. These limits

More information

How To Check If Your Router Is Working Properly

How To Check If Your Router Is Working Properly Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Dual Band Wireless-N Router WNDR3300. You can access these features by selecting the

More information

Wireless Cable Gateway CG3100Dv3

Wireless Cable Gateway CG3100Dv3 Wireless Cable Gateway CG3100Dv3 User Manual 350 East Plumeria Drive San Jose, CA 95134 USA October 2011 202-10942-01 v1.0 2011 NETGEAR, Inc. All rights reserved No part of this publication may be reproduced,

More information

QUICK START GUIDE. Cisco C170 Email Security Appliance

QUICK START GUIDE. Cisco C170 Email Security Appliance 1 0 0 1 QUICK START GUIDE Email Security Appliance Cisco C170 303357 Cisco C170 Email Security Appliance 1 Welcome 2 Before You Begin 3 Document Network Settings 4 Plan the Installation 5 Install the Appliance

More information

User s Guide. SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A

User s Guide. SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A WARRANTY REGISTRATION: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty User s Guide SNMPWEBCARD Firmware Version 12.06.0062 through 12.06.0065 Revision A

More information

IP Power Stone 4000 User Manual

IP Power Stone 4000 User Manual IP Power Stone 4000 User Manual Two Outlet Remote AC Power Controller Multi Link, Inc. 122 Dewey Drive Nicholasville, KY 40356 USA Sales and Tech Support 800.535.4651 FAX 859.885.6619 techsupport@multi

More information

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The 1-bay NAS User Guide INDEX Index... 1 Log in... 2 Basic - Quick Setup... 3 Wizard... 3 Add User... 6 Add Group... 7 Add Share... 9 Control Panel... 11 Control Panel - User and groups... 12 Group Management...

More information

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I-00453 Rev B User s Manual UPS SERIES Network Interface Card UPS-IPCARD I-00453 Rev B TABLE OF CONTENTS INTRODUCTION............................................................. 3-4 INSTALLATION GUIDE.......................................................

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3 SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,

More information

Chapter 8 Router and Network Management

Chapter 8 Router and Network Management Chapter 8 Router and Network Management This chapter describes how to use the network management features of your ProSafe Dual WAN Gigabit Firewall with SSL & IPsec VPN. These features can be found by

More information

Chapter 1 Configuring Basic Connectivity

Chapter 1 Configuring Basic Connectivity Chapter 1 Configuring Basic Connectivity This chapter describes the settings for your Internet connection and your wireless local area network (LAN) connection. When you perform the initial configuration

More information

OnCommand Performance Manager 1.1

OnCommand Performance Manager 1.1 OnCommand Performance Manager 1.1 Installation and Setup Guide For Red Hat Enterprise Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Digicom Remote Control for the SRT

Digicom Remote Control for the SRT Digicom Remote Control for the SRT To operate the SRT remotely, use Remote Desktop; this is available free for Linux, Mac OS-X (from Microsoft), and is included with Windows XP and later. As RD uses a

More information

WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 10/2015

WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 10/2015 WAP3205 v2 Wireless N300 Access Point Version 1.00 Edition 2, 10/2015 Quick Start Guide User s Guide Default Login Details Web Address http://zyxelsetup Password www.zyxel.com 1234 Copyright 2014 ZyXEL

More information

How to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29

How to Log On... 15 Main Screen... 18 Control Console Menus... 21. How to Log On... 24 Summary Page... 27 Navigation Menu... 29 Contents Introduction--1 Product Description.................................. 1 Access Procedures.................................... 3 How to Recover From a Lost Password..................... 6 Upgrading

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems SNMP Web card User s Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 3 1.1 Introduction... 3 1.2 Features... 3 1.3 Overlook... 3 1.4 Installation and

More information

QUICK START GUIDE. Cisco S170 Web Security Appliance. Web Security Appliance

QUICK START GUIDE. Cisco S170 Web Security Appliance. Web Security Appliance 1 0 0 0 1 1 QUICK START GUIDE Web Security Appliance Web Security Appliance Cisco S170 303417 Cisco S170 Web Security Appliance 1 Welcome 2 Before You Begin 3 Document Network Settings 4 Plan the Installation

More information

SecureLinx Spider Duo Quick Start Guide

SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...

More information

Securely manage data center and network equipment from anywhere in the world.

Securely manage data center and network equipment from anywhere in the world. LES1516A LES1532A LES1548A Secure Server with Cisco Pinout Securely manage data center and network equipment from anywhere in the world. To download the user manual, this quick start guide, and software

More information

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking

How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking Chapter 7 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax NEXT Wireless Router WNR854T. These features can be found by clicking on the Maintenance

More information

Chapter 4 Managing Your Network

Chapter 4 Managing Your Network Chapter 4 Managing Your Network This chapter describes how to perform network management tasks with your ADSL2+ Modem Wireless Router. Backing Up, Restoring, or Erasing Your Settings The configuration

More information

WHICH INTERFACE: USB OR ETHERNET?... 3 CONNECTING NAS DRIVE USING USB...

WHICH INTERFACE: USB OR ETHERNET?... 3 CONNECTING NAS DRIVE USING USB... Revision 1.2 INTRODUCTION... 1 CONTROLS, CONNECTORS AND INDICATORS... 1 Front Panel Area... 1 Rear Panel Area... 2 ABOUT THE HARD DISK... 2 LOCATING NAS DRIVE ON YOUR DESK... 3 WHICH INTERFACE: USB OR

More information

A More Secure and Cost-Effective Replacement for Modems

A More Secure and Cost-Effective Replacement for Modems A More Secure and Cost-Effective Replacement for Modems Lantronix, Inc. 15353 Barranca Parkway Irvine, CA 92618 Tel: +1 (800) 422-7055 Fax: +1 (949) 450-7232 www.lantronix.com Abstract For companies, service

More information

USER S GUIDE Switched Rack PDU

USER S GUIDE Switched Rack PDU Contents Introduction--1 Product Description....................................... 1 Access Procedures....................................... 3 Recover From a Lost Password..............................

More information

File Transfers. Contents

File Transfers. Contents A File Transfers Contents Overview..................................................... A-2................................... A-2 General Switch Software Download Rules..................... A-3 Using

More information

BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE

BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE BASIC INSTRUCTIONS TO CONFIGURE ZYXEL P8701T CPE USING THE WEB INTERFACE 12/11/2012 Index 1 INTRODUCTION... 1-1 2 FACTORY DEFAULT SETTINGS... 2-1 3 CPE BASIC OPERATIONS... 3-1 3.1 PASSWORD MODIFICATION...

More information

Protecting the Home Network (Firewall)

Protecting the Home Network (Firewall) Protecting the Home Network (Firewall) Basic Tab Setup Tab DHCP Tab Advanced Tab Options Tab Port Forwarding Tab Port Triggers Tab DMZ Host Tab Firewall Tab Event Log Tab Status Tab Software Tab Connection

More information

Starting a Management Session

Starting a Management Session Management Software AT-S63 Starting a Management Session AT-S63 Version 2.2.0 for the AT-9400 Layer 2+ Switches AT-S63 Version 3.0.0 for the AT-9400 Basic Layer 3 Switches 613-000817 Rev. A Copyright 2007

More information

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. www.pesa.com August 2014 Phone: 256.726.9200. Publication: 81-9059-0703-0, Rev. C

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. www.pesa.com August 2014 Phone: 256.726.9200. Publication: 81-9059-0703-0, Rev. C USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION Publication: 81-9059-0703-0, Rev. C www.pesa.com Phone: 256.726.9200 Thank You for Choosing PESA!! We appreciate your confidence in our products. PESA produces

More information

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide Symantec Database Security and Audit 3100 Series Appliance Getting Started Guide Symantec Database Security and Audit 3100 Series Getting Started Guide The software described in this book is furnished

More information

Dominion PX. General Questions. What is Dominion PX (PX)?

Dominion PX. General Questions. What is Dominion PX (PX)? Dominion PX Question General Questions What is Dominion PX (PX)? Is Raritan new to the rack power distribution unit market? Can the PX be used as a stand-alone device? Does PX work with Raritan s CommandCenter

More information

Configuring and Using AMT on TS140 and TS440

Configuring and Using AMT on TS140 and TS440 Configuring and Using AMT on TS140 and TS440 Lenovo ThinkServer TS Series Servers Lenovo Enterprise Product Group Version 1.0 September 17, 2013 2013 Lenovo. All rights reserved. LENOVO PROVIDES THIS PUBLICATION

More information

Chapter 1 Configuring Internet Connectivity

Chapter 1 Configuring Internet Connectivity Chapter 1 Configuring Internet Connectivity This chapter describes the settings for your Internet connection and your wireless local area network (LAN) connection. When you perform the initial configuration

More information

N300 WiFi Range Extender

N300 WiFi Range Extender Model EX2700 User Manual July 2014 202-11395-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on

More information

Broadband Router ALL1294B

Broadband Router ALL1294B Broadband Router ALL1294B Broadband Internet Access 4-Port Switching Hub User's Guide Table of Contents CHAPTER 1 INTRODUCTION... 1 Broadband Router Features... 1 Package Contents... 3 Physical Details...

More information

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400

User Manual. PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400. PePWave Mesh Connector Indoor Series: MC 200, E200, 400 User Manual PePWave Surf / Surf AP Indoor Series: Surf 200, E200, AP 200, AP 400 PePWave Mesh Connector Indoor Series: MC 200, E200, 400 PePWave Surf AP Series: Surf AP 200-X, E200-X, 400-X PePWave Surf

More information

,QVLJKW3RZHU 6103,3Y IRU

,QVLJKW3RZHU 6103,3Y IRU Save This Manual This manual contains important instructions and warnings that you should follow during the installation, operation, storage and maintenance of this product. Failure to heed these instructions

More information

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012 Quick Note 32 Using Digi RealPort with a Digi TransPort Router UK Support September 2012 1 Contents 1 Introduction... 3 1.1 Outline... 3 1.2 Assumptions... 3 1.3 Version... 3 2 Configuration & scenario...

More information

Maintaining the Content Server

Maintaining the Content Server CHAPTER 7 This chapter includes the following Content Server maintenance procedures: Backing Up the Content Server, page 7-1 Restoring Files, page 7-3 Upgrading the Content Server, page 7-5 Shutting Down

More information

BLACK BOX Advanced Console Server

BLACK BOX Advanced Console Server BLACK BOX Advanced Console Server Installation, Administration, and User s Guide Software Version 2.6.0 BLACK BOX Corporation 1000 Park Drive Lawrence, PA 15055-1018 877-877-2269 http://www.blackbox.com

More information

MN-700 Base Station Configuration Guide

MN-700 Base Station Configuration Guide MN-700 Base Station Configuration Guide Contents pen the Base Station Management Tool...3 Log ff the Base Station Management Tool...3 Navigate the Base Station Management Tool...4 Current Base Station

More information

DRO-210i LOAD BALANCING ROUTER. Review Package Contents

DRO-210i LOAD BALANCING ROUTER. Review Package Contents DRO-210i LOAD BALANCING ROUTER Review Package Contents Make sure that the package contains the following items. DRO-210i Load Balancing Router 2 Straight Ethernet Cables 1 Cross Over Ethernet Cable 1 Power

More information

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2 NetProbe Lite Web Based 8 Channel Sensor Collector User Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

Remote Supervisor Adapter II. User s Guide

Remote Supervisor Adapter II. User s Guide Remote Supervisor Adapter II User s Guide Remote Supervisor Adapter II User s Guide Note: Before using this information and the product it supports, read the general information in Appendix B, Notices,

More information

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version 1.1. 613-000368 Rev. B Management Software AT-S84 User s Guide For the AT-9000/24 Layer 2 Gigabit Ethernet Switch Version 1.1 613-000368 Rev. B Copyright 2006 Allied Telesyn, Inc. All rights reserved. No part of this publication

More information

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 -

PREFACE http://www.okiprintingsolutions.com 07108001 iss.01 - Network Guide PREFACE Every effort has been made to ensure that the information in this document is complete, accurate, and up-to-date. The manufacturer assumes no responsibility for the results of errors

More information

XMS Quick Start Guide

XMS Quick Start Guide 812-0055-002D XMS Quick Start Guide Overview of Quick Start Steps This guide will quickly get you up and running with the Xirrus Management System (XMS). It includes instructions for setting up the XMS

More information

Compuprint 4247 Serial Matrix Printers

Compuprint 4247 Serial Matrix Printers Compuprint 4247 Serial Matrix Printers Remote Printer Management Utility for Serial Matrix Printers MAN10300-00.00 First edition (October 2011) This edition applies to the Compuprint 4247 printers and

More information

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS MODEL ATC-2000 TCP/IP TO RS-232/422/485 CONVERTER User s Manual 1.1 Introduction The ATC-2000 is a RS232/RS485 to TCP/IP converter integrated with a robust system and network management features designed

More information

Coolmax CN-590 Network Storage Solution

Coolmax CN-590 Network Storage Solution Coolmax CN-590 Network Storage Solution Model Name Controller hip CPU OS Memory Interface CN-590 S2892 150MHz RTOS 8MB SDRAM / 1MB NOR Flash LAN Standard 10/100Base-TX Auto MDI/MDI-X Connector Type RJ-45

More information

Configuration Manual English version

Configuration Manual English version Configuration Manual English version Frama F-Link Configuration Manual (EN) All rights reserved. Frama Group. The right to make changes in this Installation Guide is reserved. Frama Ltd also reserves the

More information

Chapter 9 Monitoring System Performance

Chapter 9 Monitoring System Performance Chapter 9 Monitoring System Performance This chapter describes the full set of system monitoring features of your ProSafe Dual WAN Gigabit Firewall with SSL & IPsec VPN. You can be alerted to important

More information

LotWan Appliance User Guide USER GUIDE

LotWan Appliance User Guide USER GUIDE LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document

More information

DPXR4X1A-16NP, DPXS20A-16AU-M,

DPXR4X1A-16NP, DPXS20A-16AU-M, - 1 - Release Notes for Dominion PX Software Version 1.3.5 (firmware version will be displayed as 01.03.05 in the GUI after an upgrade) Version: DPX 1.3.5 Release Notes, Revision 1.1 Date: June 8, 2009

More information

Unified Access Point Administrator's Guide

Unified Access Point Administrator's Guide Unified Access Point Administrator's Guide Product Model: DWL-3600AP DWL-6600AP DWL-8600AP Unified Wired & Wireless Access System Release 2.0 November 2011 Copyright 2011. All rights reserved. November

More information

SkyIPCam 250W Wireless Network Camera. Model # AIC250W. User s Manual

SkyIPCam 250W Wireless Network Camera. Model # AIC250W. User s Manual SkyIPCam 250W Wireless Network Camera Model # AIC250W User s Manual Ver. 1B Table of Contents 1. Introduction... 4 2. Getting Started... 5 3. Installing the Setup Wizard... 6 4. Gathering Information...

More information

Allworx Installation Course

Allworx Installation Course VPN Hello and welcome. In the VPN section we will cover the steps for enabling the VPN feature on the Allworx server and how to set up a VPN connection to the Allworx System from your PC. Page 1 VPN The

More information

Internet Access to a DVR365

Internet Access to a DVR365 Configuration Details : Internet Access to DVR365 Page : 1 Internet Access to a DVR365 These instructions will show you how to connect your DVR365 to the internet via an ADSL broadband modem/router. The

More information

Chapter 3 Connecting the Router to the Internet

Chapter 3 Connecting the Router to the Internet Chapter 3 Connecting the Router to the Internet This chapter describes how to set up the router on your Local Area Network (LAN) and connect to the Internet. It describes how to configure your DG834GT

More information

Environmental Management System

Environmental Management System Contents Introduction--1 Product Description.................................. 1 Access Procedures................................... 3 How to Recover from a Lost Password..................... 6 Upgrading

More information

User s Manual Network Management Card

User s Manual Network Management Card User s Manual Network Management Card RMCARD202 Intelligent Network Management Card allows a UPS system to be managed, monitored, and configured Version 1.0 E-K01-SNMP005-0 TABLE OF CONTENTS Introduction

More information

LevelOne. User Manual. FBR-1430 VPN Broadband Router, 1W 4L V1.0

LevelOne. User Manual. FBR-1430 VPN Broadband Router, 1W 4L V1.0 LevelOne FBR-1430 VPN Broadband Router, 1W 4L User Manual V1.0 Table of Contents CHAPTER 1 INTRODUCTION... 1 VPN BROADBAND ROUTER FEATURES... 1 Internet Access Features... 1 Advanced Internet Functions...

More information

MasterSwitch Power Distribution Unit

MasterSwitch Power Distribution Unit MasterSwitch Power Distribution Unit AP9211 AP9212 AP9217 AP9218 User s Guide Contents MasterSwitch Power Distribution Unit Introduction................................. 1 Product Description.............................

More information

Multifunctional Broadband Router User Guide. Copyright Statement

Multifunctional Broadband Router User Guide. Copyright Statement Copyright Statement is the registered trademark of Shenzhen Tenda Technology Co., Ltd. Other trademark or trade name mentioned herein are the trademark or registered trademark of above company. Copyright

More information

DSL-2600U. User Manual V 1.0

DSL-2600U. User Manual V 1.0 DSL-2600U User Manual V 1.0 CONTENTS 1. OVERVIEW...3 1.1 ABOUT ADSL...3 1.2 ABOUT ADSL2/2+...3 1.3 FEATURES...3 2 SPECIFICATION...4 2.1 INDICATOR AND INTERFACE...4 2.2 HARDWARE CONNECTION...4 2.3 LED STATUS

More information

LevelOne WAP - 0005. User s Manual. 108 Mbps Wireless Access Point

LevelOne WAP - 0005. User s Manual. 108 Mbps Wireless Access Point LevelOne WAP - 0005 108 Mbps Wireless Access Point User s Manual TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 Features of your Wireless Access Point... 1 Package Contents... 3 Physical Details... 3 CHAPTER

More information

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business Quick Start Guide Cisco Small Business RV 120W Wireless-N VPN Firewall Package Contents Wireless-N VPN Firewall Ethernet Cable Power Adapter Quick Start Guide Documentation and Software on CD-ROM Welcome

More information