No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.
|
|
- Octavia Young
- 8 years ago
- Views:
Transcription
1 No.1 DM368 6½ digits Digital Multimeter Real 6 ½ digits readings resolution Up to 1 K rdgs/s of measurement speed and 512 K rdgs Nonvolatile Memory TrueRMS AC Voltage Current measuring Builtin 1 groups data storage,1 groups setup storage Standard temperature Sensor, builtin Thermcouple compensate in Cold terminal, support three types of temperature sensors: TC, RTD and THERM Clone or backup all the configurations within instrument into otherdm368 via Udisc UltraSensor software: Easy, convenient and flexible to support "Any sensor" measurements Real time Trend and Histogram Display functions Standard interface: USB Device, USB Host, LAN, RS232, GPIB, support Udisc storage and Web remote control (LXIC) Remote control with SCPI commands LCD Support double display, waveform display, Chinese and English menu Pushhelp makes information acquire more easier File management (support for Udisc and local storage) DM368 is a digital multimeter designed with 6 ½ digits readings resolution especially fitting to the needs of highprecision, multifunction and automatic measurement. It adopts many today's new technologies to achieve high performance, abundant features in the same class. It's designed to aim at the requirements of the largest DMM market from the research, education,industrial electronics,consumer electronics and automotive industries with its innovative technology,industry leading specifications,powerful measurement functions and broad analysis capabilities. RIGOL TECHNOLOGIES, INC.
2 DM368 6½ Digits Digital Multimeter LCD Display Navigation Key Run Control Inputs Function Keys Other Functions Size (W H D):231.6 mm 17. mm 29.5 mm Weight: ~3.2 kg (Without package) Standard interfaces: USB Host,USB Device,RS232,GPIB,LAN(LXIC) Features and Benefits Real 6½ digits readings resolution Easy to measure AC signal with double display Standard Capacitor measurement function 1 groups Preset function
3 Any sensor function Support multiple temperature sensors Support multiple commands File management (support for Udisc and local storage) Math function Statistic function Histogram display Trend display Application example Use the histogram function searching for abnormal signal : Min. Avg. Max. The small signal that scope couldn t see White Noise Histogram Submerged Pulse Noise Histogram Use Trend graphics to detect temperature trends during a long time: Long term trends
4 Abundant basic measurement functions: PERIOD SENSOR DCV DCI FREQ CONT Basic Measurements ACV ACI DIODE CAP 4WR 2WR Extended Measurement Ranges Real Time statistic analysis functions REL P/F Maximum Minimum dbm Real Time statistic analysis functions Average db Realtime Histogram Trend Graphics Standard deviation LXI Certificate and Web remote control UltraSensor Software for any types of electrical sensor measurements
5 Specifications DC Characteristics Function DC Voltage DC Current Resistance [6] Diode Test Continuity Test Range [2] 2.mV 2.V 2.V 2.V 1.V [4] 2.uA 2.mA 2.mA 2.mA 2.A 1.A [5] 2.Ω 2.kΩ 2.kΩ 2.kΩ 1.MΩ 1.MΩ 1.MΩ 2.V [7] 2.Ω Test Current or Burden Voltage <.3V <.25V <.7V <.7V <.12V <.6V 1uA 1uA 2uA 2nA 2nA 1MΩ 24 Hour [3] T CAL ± Day T CAL ± Accuracy Specifications: ± ( % of reading + % of range) [1] 1 Year Temperature Coefficient T CAL ± 5 to (T CAL 5 ) (T CAL + 5 ) to [1] Specifications are for 9minute warmup and 1NPLC integration time. For integration time <1NPLC, add the appropriate RMS Noise Adder listed in the following table. [2] 1% overrange on all ranges except DCV 1V and DCI 1A range. [3] Relative to calibration standards. [4] For each additional volt over ± 5 V, add.3mv error. [5] For continuous current > 7A DC or 7A AC RMS, 3 seconds ON and 3 seconds OFF. [6] Specifications are for 4 wire resistance measurement or 2 wire resistance measurement using REL operation. Without REL operation, add.2 Ω additional error in 2wire resistance measurement. [7] Accuracy specifications for the voltage measured at the input terminal only. 1 ma test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction. Performance Versus Integration Time 5 Hz (6 Hz) Powerline Frequency Integration Time Resolution [1] NMRR [2] Readings/s [3] RMS Noise Adder [4] (% of Range) Number of Power line Cycles (NPLC) (ppm Range) (db) Hz Hz DCV 2V DCV 2V 2V Resistance 2 kω 2 kω DCV 1 V DCI 2 ma 2 ma DCV 2 mv Resistance 2 Ω DCI 1 A [1] Typical value. Resolution is defined as the typical 2V range RMS noise (using auto zero Once ). [2] Normal mode rejection ratio for powerline frequency ±.1%. For powerline frequency ± 1%, subtract 2 db. For ± 3%, subtract 3dB. [3] Maximum rate for DCV, DCI, 2wire resistance and 4wire resistance functions. [4] The basic DC accuracy specifications include RMS noise at 1 NPLC. For <1 NPLC, add RMS Noise Adder to the basic DC accuracy specifications.
6 SFDR & SINAD [1] Function DCV DCI Range 2 mv 2 V 2 V 2 V 1 V 2 ua 2 ma 2 ma 2 ma 2 A SpuriousFree Dynamic Range (SFDR) [1] Typical value. 1dBFS, 1kHz single tone. 1 us aperture time, zero trigger delay, auto zero off and 496 samples. SignaltoNoiseandDistortion (SINAD) Measuring Characteristics DC Voltage Input Resistance Input Protection Input Offset Current CMRR (common mode rejection ratio) Resistance Measurement Method Opencircuit Voltage Max. Lead Resistance (4wire) Input Protection Offset Compensation DC Current Shunt Resistor Input Protection 2 mv, 2 V, 2 V ranges: Selectable 1 MΩ or > 1 GΩ (For these ranges, input beyond ±26V are clamped through 16 kω (typical) 2 V and 1 V ranges: 1 MΩ ± 1% 1 V 5 pa, at 25, typical 14 db for 1 kω unbalance in LO lead, ± 5 VDC peak maximum Selectable 4wire or 2wire resistance Current source referenced to LO input Limited to < 1V 1% of range per lead for 2 Ω, 2 kω ranges, 1 kω per lead on all other ranges 1 V on all ranges Available on 2 Ω, 2kΩ and 2 kω ranges 1 Ω for 2 ua, 2 ma 1 Ω for 2 ma, 2 ma.1 Ω for 2 A, 1 A Externally accessible 5 ma, 25 V fast blow fuse at the rear panel for 2 ua, 2 ma, 2 ma and 2 ma ranges. Internal 1 A, 25 V slow blow fuse for 2 A and 1 A ranges Continuity/Diode Test Response Time Continuity Threshold Autozero OFF Operation (typical value) 3 samples/sec, with audible tone Adjustable from 1 Ω to 2 Ω Following instrument warmup at the environment temperature ±1 and <5 minutes, add.1 % range + 2 uv for DCV and 2 mω for resistance. Settling Time Considerations Reading settling times are affected by source impedance, cable dielectric characteristics and input signal changes. The default measurement delay is selected to give first reading right for most measurements. Measurement Considerations Telon or other highimpedance, lowdielectric absorption wire insulation is recommended for these measurements.
7 AC Characteristics Accuracy Specifications: ±(% of reading + % of range) [1] Function True RMS AC Voltage [4] True RMS AC Current [8] Range [2] 2. mv 2. V 2. V 2. V 75. V [5] 2. ua 2. ma 2. ma 2. ma 2. A 1. A [6] Frequency Range 5Hz 1Hz 1Hz 2kHz 2kHz 5kHz 5kHz 1kHz 1kHz 3kHz 5Hz 1 Hz 1Hz 2kHz 2kHz 5kHz 5kHz 1kHz 1kHz 3kHz 5Hz 1Hz 1Hz 2kHz 2kHz 5kHz 5kHz 1kHz 1kHz 3kHz 5Hz 1Hz 1Hz 2kHz 2kHz 5kHz 5kHz 1kHz 1kHz 3kHz 5Hz 1Hz 1Hz 2kHz 2kHz 5kHz 5kHz 1kHz 1kHz 3kHz 5Hz1Hz 1Hz5kHz 5kHz1kHz 5Hz 1Hz 1Hz 5kHz 5kHz 1kHz 5Hz 1Hz 1Hz 5kHz 5kHz 1kHz 5Hz 1Hz 1Hz 5kHz 5kHz 1kHz 5Hz 1Hz 1Hz 5kHz 5kHz 1kHz 5Hz 1Hz 1Hz 5kHz 24 Hour [3] T CA L ± Day T CAL ± Year T CAL ± Temperature Coefficient to (T CAL 5 ) (T CAL + 5 ) to
8 Additional Low Frequency Errors (% of reading) Additional Crest Factor Errors (nonsinewave) [7] Frequency AC Filter Crest Factor Error (% of reading) Slow Medium Fast 1Hz 2Hz 2Hz 4Hz 4Hz 1Hz 1Hz 2Hz 2Hz 1kHz >1kHz [1] Specifications are for 9minute warmup, slow ac filter and sinewave input. [2] 1% overrange on all ranges except ACV 75 V and ACI 1 A ranges. [3] Relative to calibration standards. [4] Specifications are for sinewave input >5% of range. For inputs within 1% and 5% of range and <5 khz, add.1% of range additional error. For 5kHz to 1kHz, add.13% of range additional error. [5] ACV 75 range limited to 8x17 VoltHz. For input over 3V rms, add.7mv error for each additional volt. Measuring Characteristics True RMS AC Voltage Measurement Method Crest Factor Input Impedance Input Protection AC Filter Bandwidth CMRR (common mode rejection ratio) True RMS AC Current Measurement Method Crest Factor Max. Input Shunt Resistor Input Protection [6] For continuous current > DC 7A or AC RMS 7A, 3 seconds ON and 3 seconds OFF. [7] For frequency blow 1 Hz, the specification of slow filter is only for sinewave input. [8] Specifications are for sinewave input >5% of range. For inputs within 1% to 5% of range, add.1% of range additional error. Specifications are typical values for 2uA and 2mA, 2A and 1A ranges when frequency >1kHz. ACcoupled TrueRMS measurement with up to 4 V DC of bias at on any range. 5 at full range 1MΩ ± 2% in parallel with <15pF capacitance on any range 75V rms on all ranges Slow: 3 Hz 3 khz Medium: 2Hz 3kHz Fast: 2 Hz 3 khz 7 db, for the 1 kω unbalance in LO lead, < 6 Hz, ± 5 VDC peak maximum Direct coupled to the fuse and shunt; ACcoupled True RMS measurement (measure the AC component only). 3 at full range DC + AC current peak value < 3% of range. The RMS current < 1 A rms including the DC component. 1Ω for 2uA, 2mA 1Ω for 2mA, 2mA.1Ω for 2A, 1A Externally accessible 5mA, 25V fast blow fuse at the rear panel for 2uA, 2mA, 2mA and 2mA ranges. Internal 1A, 25 V slow blow fuse for 2A and 1A ranges. Settling Time Considerations The default measurement delay is selected to give first reading right for most measurements. Make sure the RC circuit of input terminal has been fully settled (about 1s) before accurate measurement. Applying > 3 Vrms (or > 5Arms) will cause selfheating in signalconditioning components and these error are included in the instrument specifications. Internal temperature changes due to selfheating may cause additional error on lower ac voltage ranges. The additional error will be lower than.2% of reading and will generally dissipate within a few minutes. Frequency and Period Characteristics Function Frequency, Period Range 2 mv to 75 V Frequency Range 3 Hz 5 Hz 5 Hz 1 Hz 1 Hz 4 Hz 4 Hz 3 khz 3 khz 1 MHz 24 Hour [3] T CAL ± Day T CAL ± Accuracy Specifications: ±(% of reading) [1][2] 1 Year Temperature Coefficient T CAL ± to (T CAL 5 ) (T CAL +5 ) to Frequency 3 Hz5Hz 5 Hz1Hz 1 Hz4Hz 4 Hz1Hz 1 Hz3Hz 3 Hz1 khz >1kHz 1 s (.1ppm).1 s (1ppm) Gate Time (Resolution).1 s (1ppm) Additional Low Frequency Errors: (% of reading).1 s (1ppm) [1] Specifications are for 9 minutes warmup, using 1s gate time. [2] For frequency 3 khz, the specification is the 1% to 11% of range of the AC input voltage. For frequency > 3 khz, the specification is the 2% to 11% of range of the AC input voltage. The maximum input is limited to 75V rms or 8 17 VoltsHz (whichever is less). 2 mv range is full range input or input that is larger than the full range. For 2mV to 2mV, multiply % of reading error 1. [3] Relative to calibration standards.
9 Measuring Characteristics Frequency and Period Measurement Method Input Impedance Input Protection Capacitance Characteristics Function Range [2] Test Current Capacitance 2.nF 2.nF 2.nF 2.uF 2.uF 2.uF 2.mF 2.mF 1.mF Measuring Characteristics Capacitance Measurement Measurement Method Connection Type Reciprocalcounting technique, ACcoupled input using the AC voltage function. 1 MΩ ± 2% in parallel with < 15 pf capacitance on any range 75 V rms on all ranges Measurement Considerations All frequency counters are susceptible to error when measuring low voltage, low frequency signals. Shielding inputs from external noise pickup is critical for minimizing measurement errors. Settling Time Considerations Errors will occur when attempting to measure the frequency or period of an input following a dc offset voltage change. Make sure the RC circuit of input terminal has been fully settled (about 1s) before accurate measurement. 2nA 2uA 1uA 1uA 1 Year T CAL ± Apply constant current into the capacitance, and measure the voltage changing rate. 2wire Measurement Considerations Since small capacitance measurements are susceptible to the external noise, shielding inputs from external noise pickup is critical for minimizing measurement errors. Accuracy Specifications: ± (% of reading + % of range) [1][2] Temperature Coefficient to (T CAL 5 ) (T CAL +5 ) to [1] Specifications are for 9 minutes warm up and using REL operation. Additional errors may be caused by non film capacitors. [2] Specifications are the 1% to 11% of range on 2nF range and 1% to 11% of range on all other ranges. Temperature Characteristics Function Temperature Probe Type RTD [2] (R is within 49 Ω and 2.1 kω) Thermal Resistance Thermocouple [3] Type α =.385 α =.389 α =.391 α = kω 3 kω 5 kω 1 kω 3 kω B E J K N R S T [1] Specifications are for 9 minutes warmup. Exclusive of sensor error. [2] Specification is for 4WR sensor measurement or 2WR measurement using REL operation. Optimum Range 2 to 66 2 to 66 2 to 66 2 to 66 4 to 15 4 to 15 4 to 15 4 to 15 4 to 15 to to 1 21 to to to to to to 4 1 Year T CAL ± Accuracy Specifications [1] Temperature Coefficient to (T CAL 5 ) (T CAL +5 ) to [3] Relative to cold junction temperature, accuracy is based on ITS9. Builtin cold junction temperature refers to the temperature inside the banana jack and its accuracy is ± 2.5. Measuring Characteristics Measurement Considerations The builtin cold junction temperature tracks the temperature inside the banana jack. The change of the temperature in banana jack might cause additional error. When using the builtin cold junction compensation, connect the sensor terminal of the thermocouple to the banana jack and warm it up for more than 3 minutes to minimize the error.
10 Measurement Rate Function DC Voltage DC Current 2 wire Resistance 4 wire Resistance AC Voltage AC Current [2] Frequency and Period [4] Capacitance [5] Setting.6 NPLC Integration Time.2 NPLC.6 NPLC.2 NPLC 1 NPLC 2 NPLC 1 NPLC 1 NPLC 3 Hz AC Filter 2 Hz 2 Hz 2 Hz 1 s Gate Time.1 s.1 s.1 s [1] Auto trigger, zero trigger delay, auto zero off, auto range off, math function off and external interface off. [2] Use the default trigger delay setting. [3] The maximum rate available when trigger delay is set to. Integration Time 1 (1) us 4 (333) us 1.2 (1) ms 4 (3.33) ms 2 (16.7) ms 4 (33.3) ms 2 (167) ms 2 (1.67) s Readings/s 5Hz (6Hz) 1 (1) 25 (3) 833 (1) 25 (3) 5 (6) 25 (3) 5 (6).5 (.6) [3] [4] 2 V range, fast filter, 1kHz input. [5] Measure 2 nf capacitance on 2 nf range. The measurement period changes with the capacitance under test. The maximum measurement period on 1mF is 4 s (typical value). Other Measurement Characteristics Triggering and Storage Trigger Time Base Resolution Trigger Delay Sample Timer Internal Trigger Level Accuracy Reading Hold Sensitivity Single Trigger Samples External Trigger Input VMC Output Pretrigger or Postrigger, Internal Trigger or External Trigger, Rising Edge Trigger or Falling Edge Trigger us,.1% Accuracy to 36 s available (about 33 μs step size) to 36 s available (about 33 μs step size) ± 1% of range.1%,.1%, 1% or 1% of reading 1 to 5 Level: 5 V TTL compatible Impedance: > 3 kω in parallel with 5 pf Delay: < 5 μs Jitter: < 5 μs (ACV, ACI, FREQ and PREIOD < 2ms) Polarity: selectable rising edge or falling edge Maximum Rate: 3/s Minimum Pulse Width: 2 μs Level: 5 V TTL compatible Output Impedance: 1 Ω, typical Output Polarity: Falling Edge Pulse Width: about 2μs History Record and Storage Volatile Memory Nonvolatile Memory 512 k reading history data record 1 sets history data storage (5 readings/group) 5 sets sensor data storage (5 readings/group) 1 sets instrument setup storage 5 sets Anysensor setup storage Support USB flash device backup data and setting.
11 General Specifications Display Power Supply Power Consumption Working Environment Storage Temperature Operation Altitude Safety EMC Weight Dimension Remote Interface Programming Language LXI Compatibility Warmup Time LCD, dual display, graphical menu, selectable Chinese or English, online help. AC 1 V 12 V, 45 Hz 44 Hz AC 2 V 24 V, 45 Hz 66 Hz Detect the powerline frequency automatically at poweron, 4Hz defaults to 5Hz 25 VA Max Full accuracy for to 5 Full accuracy to 4, 8% R.H., Noncoagulation 4 to 7 Up to 2 m IEC 6111; EN 6111; UL 6111; CAN/CSAC22.2 No Measurement CAT I 1 V/CAT II 3 V Pollution Degree 2 EN About 3.2 kg (without package) (height width length): 17.mm 231.6mm 29.5mm GPIB, 1/1 Mbit LAN, USB 2. Full Speed Device & Host (support USB flash device), RS232C SCPI LXI Class C, Version minutes DM368 Ordering Information Model Standard Accessories Optional Accessories Description DM368 (6 ½, dualdisplay) Power Cord conforming to the standard of the country Two Test Leads (black and red) Two Alligator Clips (black and red) USB Cable Four Spare Fuses (two kinds): 2 AC, 25 V, T25 ma fuses 2 AC, 25 V, T125 ma fuses Quick Guide Resource CD (User s Guide and Application Software) Kelvin Test Clip RS232 Cable Rack Mount Kit Order Number DM368 CBUSB15 RMDM3 NOTE: All the standard or optional accessories can be ordered from you local RIGOL Office.
12 No For further information, please contact Rigol local Distributors
2000 6½-Digit Multimeter
13 built-in measurement functions 2000 readings/second at 4½ digits Optional scanner cards for multipoint measurements IEEE-488 and RS-232 interfaces Fluke 8840/42 command set Ordering Information 2000
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationAgilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet
Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price Data Sheet Features 120000 counts resolution 16 built-in measurement functions including temperature and
More informationFluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
More informationFluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter
Fluke 2638A Hydra Series III Data Acquisition System/ Digital Multimeter Technical Data Price-performance breakthrough in a stand-alone data acquisition system The Fluke Hydra Series III continues the
More informationAgilent U1230 Series Handheld Digital Multimeters (DMMs)
Agilent U1230 Series Handheld Digital Multimeters (DMMs) Data Sheet Retool your expectations with the new Agilent U1230 Series Handheld DMMsthe first to combine a built-in LED flashlight, both audible
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
More informationPICOTEST. M3500A 6.5 Digit Digital Multimeter. User s Manual
PICOTEST M3500A 6.5 Digit Digital Multimeter User s Manual Printed date: 02/2009 M3500A DMM 2 User s Manual Table of Contents 1 GENERAL INFORMATION... 6 1.1 FEATURE OVERVIEW... 6 1.2 WARRANTY INFORMATION...
More informationDataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain
DataSheet SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806 Application Domain Outdoor measure Circuit measure Wind power, PV power and other new energy equipment test Automotive
More informationUser's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationAPSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer
APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is
More informationDual Display Digital Multimeter
Dual Display Digital Multimeter GDM-8246 GW INSTEK PART NO. 82DM-82460MG1 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual
More informationU1602A Handheld Oscilloscopes, 20 MHz
Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product
More informationDP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.
DP800 Programmable Linear DC Power Supply DP832A/832:3 Outputs, CH CH2,CH3,Total Power up to 95W DP83A:3 Outputs, CH CH2,CH3,Total Power up to 60W DP8A: Output, 40V/5A or 20V/0A, with Remote Sense, Total
More information1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
More informationTechnical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More information72-7730 72-7732 Intelligent Digital Multimeters
72-7730 72-7732 Intelligent Digital Multimeters Model 72-7730/72-7732 OPERATING MANUAL TABLE OF CONTENTS CHAPTER TITLE PAGE 1. Before You Start Overview Inspection Safety Information Rules For Safe Operation
More informationAgilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
More informationAgilent E5100A Network Analyzer
Agilent E5100A Network Analyzer Data Sheet These specifications are the performance standards or limits against which the instrument is tested. When shipped from the factory, the E5100A meets the specifications
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
More informationHigh Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
More informationSL Series AC and DC Electronic Loads
SL Series AC and DC Electronic Loads Applications AC & DC Power Supply Testing Rechargeable batteries and chargers Fuel cell test - cells and stacks PFC circuit test Pulsed LED Test and Burn-in Laser Diode
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationDigital Clamp-on DMMs with uncompromising performance
Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy
More informationLoop Calibration and Maintenance
Loop Calibration and Maintenance Application Note Introduction Process instrumentation requires periodic calibration and maintenance to ensure that it is operating correctly. This application note contains
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationAgilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
More informationFluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
More informationLM118/LM218/LM318 Operational Amplifiers
LM118/LM218/LM318 Operational Amplifiers General Description The LM118 series are precision high speed operational amplifiers designed for applications requiring wide bandwidth and high slew rate. They
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationR&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
More information5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument
5320A Multifunction Electrical Tester Calibrator Verify and calibrate electrical test tools with a single instrument 2 5320A Multifunction Electrical Tester Calibrator: Wide workload coverage with a single
More informationPhysical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
More informationModel UT71A/B OPERATING MANUAL
Model UT71A/B OPERATING MANUAL CHAPTER TITLE PAGE 1. 2. Before You Start Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Getting Acquainted Turning
More informationDataSheet. SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062. Features & Benefits
DataSheet SHS1000 Series Handheld Digital Oscilloscope SH1102/SHS1062 Features & Benefits SHS1000 Series have 2 channels; provide functions as Oscilloscope, Multimeter and Recorder (TrendPlot and waveform
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More information5000V Graphical Megohmmeter Model 5070
5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated
More informationRIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design
RIGOL Data Sheet DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D Product Overview DS1000E, DS1000D series are kinds of economical digital oscilloscope with high-performance.
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
DCS Series 1 kw, 1.2 kw, & 3 kw AVAILABLE WITH LXI STANDARD COMPLIANT ETHERNET Applications Automotive Electronics Rackmount ATE System Battery Charging DCS Series DCS Series: 1 kw, 1.2 kw, & 3 kw DCS
More informationAgilent U1270 Series Handheld Digital Multimeters
Agilent U1270 Series Handheld Digital Multimeters Be Ready for Winter Data Sheet NEW Features OLED display with 2000:1 contrast ratio and 160 degrees viewing angle 3,4 30,000-count resolution Measure up
More informationwww.elektroexpressz.hu
www.elektroexpressz.hu 2013 1 UT10 SERIES / UT20 SERIES Modern Pocket - Size Digital Multimeters Pocket-Size Digital Multimeters UNI-T UT10A UT10A DC Voltage 400mV/4V/40V/300 ±(0.8%+1) AC Voltage 4V/40V/300V
More informationwww.jameco.com 1-800-831-4242
Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. LF411 Low Offset, Low Drift JFET Input Operational Amplifier General Description
More informationPIN CONFIGURATION FEATURES ORDERING INFORMATION ABSOLUTE MAXIMUM RATINGS. D, F, N Packages
DESCRIPTION The µa71 is a high performance operational amplifier with high open-loop gain, internal compensation, high common mode range and exceptional temperature stability. The µa71 is short-circuit-protected
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationMulti-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
More informationUT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
More informationOne Port Network Analyzer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test
More informationElectronic Measurement Instruments. Selection Guide
Electronic Measurement Instruments Selection Guide Digital Oscilloscopes DS6000 DS6104/DS6102 (1GHz) DS6064/DS6062 (600MHz) 5GSa/s Real-time Sample Rate 140Mpts Memory Depth (Std.) 2 or 4 channels Up to
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationFFT Spectrum Analyzers
FFT Spectrum Analyzers SR760 and SR770 100 khz single-channel FFT spectrum analyzers SR760 & SR770 FFT Spectrum Analyzers DC to 100 khz bandwidth 90 db dynamic range Low-distortion source (SR770) Harmonic,
More informationUsers Manual. ProcessMeter
787 ProcessMeter Users Manual April 1997, Rev.3, 12/01 1997, 1898, 2000, 2001 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies. LIMITED
More informationAgilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More informationKONSTANTER SPL 250-30 / SPL 400-40 Programmable Electronic Load
3-349-701-03 1/1.13 4 operating modes: constant current, constant voltage, constant load, constant power High speed sequence and transient measurement, short-circuit proof, battery discharging and other
More informationModel 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
More informationProgrammable Single-/Dual-/Triple- Tone Gong SAE 800
Programmable Single-/Dual-/Triple- Tone Gong Preliminary Data SAE 800 Bipolar IC Features Supply voltage range 2.8 V to 18 V Few external components (no electrolytic capacitor) 1 tone, 2 tones, 3 tones
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationR&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
More informationManual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
More information3522-50/3532-50 LCR HiTESTER Components measuring instruments
Improved with Faster Measurement! 3522-50/3532-50 LCR HiTESTER Components measuring instruments 2001 Improved 3522-50 / 3532-50 further shortens line tact time with its high-speed measuring power High
More informationM 140i. Multifunction Calibrator. Operation Manual
M 140i Multifunction Calibrator Operation Manual M-140i Multifunction Calibrator MEATEST, s.r.o. 2 Operation Manual v33 MEATEST, s.r.o. M-140i Multifunction Calibrator Content Operation Manual... 1 Basic
More informationSeries AMLDL-Z Up to 1000mA LED Driver
FEATURES: Click on Series name for product info on aimtec.com Series Up to ma LED Driver Models Single output Model Input Voltage (V) Step Down DC/DC LED driver Operating Temperature range 4ºC to 85ºC
More informationLM1036 Dual DC Operated Tone/Volume/Balance Circuit
LM1036 Dual DC Operated Tone/Volume/Balance Circuit General Description The LM1036 is a DC controlled tone (bass/treble), volume and balance circuit for stereo applications in car radio, TV and audio systems.
More informationR&S ZVA Vector Network Analyzer Specifications
www.atecorp.com 8-44-ATEC (2832) R&S ZVA Vector Network Analyzer Specifications ZVA_dat-sw_en_523-568-22_v_cover.indd Data Sheet. E stablished 98 Advanced Test Equipment Rentals Test & Measurement 4.5.22
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationAgilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm
More informationCond-IS RF Conducted Immunity System
Cond-IS RF Conducted Immunity System About RF Conducted Immunity In the global contest of EMC testing for residential and industrial EUTs (Equipments Under Test) RF Conducted Immunity compliance verification
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationUser Guide. Model 380260 Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
More informationMODEL 1211 CURRENT PREAMPLEFIER
MODEL 1211 CURRENT PREAMPLEFIER Phone: (607)539-1108 Email: info@dlinstruments.com www.dlinstruments.com The Model 1211 Current Preamplifier was designed to provide all of the features required of a modern
More informationDATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS. 1996 Jan 08
INTEGRATED CIRCUITS DATA SHEET power amplifier with diagnostic facility Supersedes data of March 1994 File under Integrated Circuits, IC01 1996 Jan 08 FEATURES Requires very few external components High
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationVoltech DC1000. Precision DC Bias Current Source
DC1000 Precision DC Bias Current Source DC1000 Precision DC Bias Current Source TM Integral Rack Mount Lugs High Contrast Green LED Display Easy Control Rotary Knob Output LED Indicator DC 1000 OUTPUT
More informationDesigning the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station +82-2-578-6516 І sales@wonatech.
ZIVE Electrochemical Workstations ZIVE SP2 Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station +82-2-578-6516 І sales@wonatech.com www.wonatech.com
More informationDDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
More informationLM101A LM201A LM301A Operational Amplifiers
LM101A LM201A LM301A Operational Amplifiers General Description The LM101A series are general purpose operational amplifiers which feature improved performance over industry standards like the LM709 Advanced
More informationHow To Use A Sound Card With A Subsonic Sound Card
!"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+
More informationMODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C
ADS1000C & CA Series DIGITAL STORAGE OSCILLOSCOPE 25MHz / 60MHz / 100MHz / 150MHz FEATURES 500MSa/s & 1GSa/s Sampling Rate 2 Channels 5.7in LCD Color USB Host/Device: Support USB Printer and USB Flash
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationThe table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationBaseband delay line QUICK REFERENCE DATA
FEATURES Two comb filters, using the switched-capacitor technique, for one line delay time (64 µs) Adjustment-free application No crosstalk between SECAM colour carriers (diaphoty) Handles negative or
More informationSELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)
OBSOLETE NMPD0 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Efficiency (Min.) Power (Max.) V V % W NMPD003C 3. 9.50 NMPD005C 5. 9.5 NMPD0C. 0 0.00 NMPD05C 5. 9 0.00 FEATURES RoHS
More informationCA723, CA723C. Voltage Regulators Adjustable from 2V to 37V at Output Currents Up to 150mA without External Pass Transistors. Features.
CA73, CA73C Data Sheet April 1999 File Number 788. Voltage Regulators Adjustable from V to 37V at Output Currents Up to 1mA without External Pass Transistors The CA73 and CA73C are silicon monolithic integrated
More informationOp Amp Circuit Collection
Op Amp Circuit Collection Note: National Semiconductor recommends replacing 2N2920 and 2N3728 matched pairs with LM394 in all application circuits. Section 1 Basic Circuits Inverting Amplifier Difference
More informationwww.keithley.com LLM 6 th Edition Low Level Measurements Handbook Precision DC Current, Voltage, and Resistance Measurements
www.keithley.com LLM 6 th Edition Low Level Measurements Handbook Precision DC Current, Voltage, and Resistance Measurements Low Level Measurements Handbook Precision DC Current, Voltage, and Resistance
More informationTLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009
May 2009 TLI4946 High Precision Hall Effect Latches for Industrial and Consumer Applications TLI4946K, TLI4946-2K, TLI4946-2L Datasheet Rev. 1.0 Sense and Control Edition 2009-05-04 Published by Infineon
More informationNEW PRODUCT ANNOUCEMENT
URRllEN TECHNOLOGY NEW PRODUCT ANNOUCEMENT ADS1000CL+ / CML DSO Series 25MHz ~ 200MHz We are glad to introduce to our global customers our new series of Digital Storage Oscilloscope under ADS1000 CL+ &
More information