WatchGuard XCSv Setup Guide

Size: px
Start display at page:

Download "WatchGuard XCSv Setup Guide"

Transcription

1 WatchGuard XCSv Setup Guide All XCSv Editions

2 Copyright and Patent Information Copyright WatchGuard Technologies, Inc. All rights reserved. WatchGuard, the WatchGuard logo, LiveSecurity, and any other mark listed as a trademark in the Terms of Use portion of the WatchGuard Web site that is used herein are either registered trademarks or trademarks of WatchGuard Technologies, Inc. and/or its subsidiaries in the United States and/or other countries. All other trademarks are the property of their respective owners. Printed in the United States of America. Revised: October 15, 2013 Complete copyright, trademark, patent, and licensing information can be found in the WatchGuard product documentation. You can find this document online at: Notice to Users Information in this guide is subject to change without notice. Updates to this guide are posted at: Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this guide may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of WatchGuard Technologies, Inc. ABOUT WATCHGUARD WatchGuard offers affordable, all-in-one network and content security solutions that provide defense-in-depth and help meet regulatory compliance requirements. The WatchGuard XTM line combines firewall, VPN, GAV, IPS, spam blocking and URL filtering to protect your network from spam, viruses, malware, and intrusions. The new XCS line offers and web content security combined with data loss prevention. WatchGuard extensible solutions scale to offer right-sized security ranging from small businesses to enterprises with 10,000+ employees. WatchGuard builds simple, reliable, and robust security appliances featuring fast implementation and comprehensive management and reporting tools. Enterprises throughout the world rely on our signature red boxes to maximize security without sacrificing efficiency and productivity. For more information, please call or visit ADDRESS 505 Fifth Avenue South Suite 500 Seattle, WA SUPPORT U.S. and Canada All Other Countries SALES U.S. and Canada All Other Countries ii WatchGuard XCSv

3 The WatchGuard XCS is an easy-to-use, all-inclusive and web appliance that provides security and privacy of inbound and outbound traffic. The WatchGuard XCS provides content security that enables data loss prevention, encryption, and content filtering with integrated threat prevention for viruses, spam, spyware, phishing, and malware attacks, all in a secured appliance. WatchGuard XCSv is a new and web security solution that provides all the security features of our WatchGuard XCS technology optimized for a VMware or Microsoft Hyper-V virtual machine environment. You can use the WatchGuard XCS Web UI to manage an XCSv device just as you manage any other WatchGuard XCS device. This guide introduces the WatchGuard XCSv and provides detailed information on how to configure your virtual environment and install the XCSv software. WatchGuard XCSv Documentation You can use the online help manual for the majority of your documentation needs. To access the online help, from the Web UI, select Support > Online Manual. You can view and download the most current documentation for the WatchGuard XCS on the WatchGuard Product Documentation page: Setup Guide 1

4 WatchGuard XCSv Licensing XCSv devices are licensed in several editions that provide different levels of scalability and performance: Small Office Edition Medium Office Edition Large Office Edition Large Office XC Edition When you activate your XCSv device, you receive a feature key that enables the WatchGuard XCS capabilities for the XCSv edition you have licensed. You can upgrade from one XCSv edition to another. Note To activate your device in the Setup Wizard, you must have the device serial number (V2C9xxxxxxxxx). You cannot use the serial number V2C DC79, which is the default serial number for an new unactivated device. For a full description of the features and capabilities of each XCSv edition, see the Products & Services section of the WatchGuard web site at Get a Feature Key from LiveSecurity A feature key is a license that enables you to activate your purchased feature set on your WatchGuard XCSv. You must register the device serial number on the WatchGuard LiveSecurity web site and retrieve your feature key before adding it to the WatchGuard XCSv. To retrieve a feature key from the LiveSecurity web site: 1. Open a web browser and go to: 2. If you have not already logged in to LiveSecurity, the LiveSecurity Log In page appears. You can create an account if this is your first time logging in. 3. Enter your LiveSecurity user name and password. 4. The Activate Products page appears. 5. Enter the serial number for the product, including the hyphens. For example, V2C9xxxxx-xxxx. 6. Click Continue. 7. Follow the prompts to activate your device. 8. Copy the feature key to a text file and save it on your computer. 9. Click Finish. 2 WatchGuard XCSv

5 Installation Prerequisites VMware These sections describe the installation prerequisites for XCSv on VMware and Microsoft Hyper-V. You must install the XCSv virtual device in a VMware environment that meets these requirements. VMware To install an XCSv virtual device, you must have a VMware vsphere Hypervisor/ESXi v4.1 Update 2 (or later version) host installed on any supported server hardware. Note Make sure your VMware vsphere/esxi software is updated to the latest patch level. You must also install the VMware vsphere Client on a supported Windows computer to manage the virtual machines on your VMware host. VMware Tools is installed by default with the XCSv virtual device. VMware Tools is a suite of utilities that enhances and improves the performance and management of the virtual machine, and includes the ability to cleanly power off or reset the guest operating system software from the host system. Hardware The hardware requirements for XCSv are the same as the hardware requirements for VMware vsphere Hypervisor/ESXi. For information about VMware hardware compatibility, see the VMware Compatibility Guide at: WatchGuard XCSv requires that your host hardware supports Intel Virtualization Technology (Intel VT) or AMD Virtualization (AMD-V) and has these options enabled in the host system BIOS. For more information about Intel VT compatibility, see the Intel Virtualization Technology List at: AMD-V is supported in all K8 AMD (Athlon 64) processors from revision F, and all newer processors support AMD-V technology. Features Not Supported These features are not supported for use with WatchGuard XCSv on VMware: Network storage disks for the virtual host are not supported. XCSv does not support vmotion for virtual device migration between VMware hosts. XCSv console options: Serial console This feature is redundant with the physical host system serial console. UPS configuration UPS communications must be configured on the physical host system. Setup Guide 3

6 Microsoft Hyper-V You must install the XCSv virtual device in a Hyper-V environment that meets these requirements. Hyper-V Hyper-V role on Windows Server 2008 R2 or Windows Server 2012, or stand-alone version of Hyper-V Server 2008 R2 or Hyper-V Server Make sure your Windows Server or Hyper-V Server software is updated to the latest patch level. You can use the Hyper-V Manager on Windows Server 2012 to deploy, configure, and provision the XCSv virtual machine in the Hyper-V environment. You can also use System Center Virtual Machine Manager (VMM) interface, or a Hyper-V role on a client computer instead of Hyper-V Manager. Hardware The hardware requirements for XCSv are the same as the hardware requirements for Hyper-V on Windows Server 2008 R2 or Windows Server Network You can configure a maximum of 8 interfaces. Features Not Supported These features are not supported for use with WatchGuard XCSv on Hyper-V: XCSv does not support the dynamic memory setting on Hyper-V. The Data Exchange and Volume Backup features are not supported. Time synchronization is not supported. We recommend you use an NTP server in the XCSv network configuration. XCSv console options: Serial console This feature is redundant with the physical host system serial console. UPS configuration UPS communications must be configured on the physical host system. 4 WatchGuard XCSv

7 Recommended Resource Allocation WatchGuard XCSv performance is heavily dependent on CPU, memory, and disk resources. Resources are shared between all virtual machines on a virtual host, and you must make sure that enough resources are available to the XCSv virtual machine. To enable all functionality and provide optimal performance for your XCSv edition, you must allocate these resources to the XCSv virtual machine: Small Office Edition Medium Office Edition Large Office Edition Large Office XC Edition Virtual CPUs Memory 2 GB 2 GB 4 GB 8 GB Network Adapters OS Disk space 24 GB 24 GB 24 GB 24 GB (Fixed) Data Disk Space 40 GB 80 GB 160 GB 256 GB For information about how to add resources for a VMware virtual machine, see VMware Virtual Machine Resource Allocation on page 12. For information on monitoring VMware resource usage, see Resource Monitoring on VMware on page 43. For information about how to add resources for a Hyper-V virtual machine, see Hyper-V Virtual Machine Resource Allocation on page 20. For information on monitoring Hyper-V resource usage, see Resource Monitoring on Hyper-V on page 45. Setup Guide 5

8 Deployment The WatchGuard XCSv is designed to be situated between internal servers and clients, and external servers on the Internet so that there are no direct connections between external and internal systems. The WatchGuard XCSv is typically installed in one of these locations: On the DMZ (Demilitarized Zone) of a network firewall Behind the existing firewall on the internal network In parallel with a network firewall Messaging traffic is redirected from either the external interface of the network firewall or from the external router to the WatchGuard XCSv. When the WatchGuard XCSv accepts and processes a message, the device initiates a connection to the internal mail servers to deliver the messages. WatchGuard XCSv deployed on the DMZ of the network firewall The secure architecture of the hardware appliance-based WatchGuard XCS eliminates the risk associated with deploying a physical appliance on the perimeter of a network. Because the WatchGuard XCSv is installed as a virtual machine on a host where the host operating system can be vulnerable to security issues, we recommend you install the virtual host and XCSv virtual machine on the DMZ of your network firewall or behind your network firewall for greater security. See the WatchGuard XCS User Guide for detailed information on the advantages and disadvantages of each type of deployment. Cluster Support Clustering provides a scalable, redundant messaging security infrastructure that enables two or more XCSv devices to act as a single logical unit for processing messages for redundancy and high availability benefits. You can use multiple instances of XCSv in a cluster. To provide proper hardware redundancy, we recommend you run clustered XCSv devices on separate virtual host systems. If you run multiple XCSv devices on the same virtual host hardware, you can provide software redundancy in the event a specific XCSv device is unavailable, but this does not provide redundancy if the virtual host hardware or software fails. For more information on configuring XCSv clustering with a virtual host, see Cluster Configuration on page WatchGuard XCSv

9 VMware Installation Before You Begin To prepare for your installation, make sure you have these items: VMware vsphere Hypervisor/ESXi 4.1 Update 2 (or later version) host installed on a supported server platform. VMware vsphere 4.1 (or later version) client installed on a Windows computer WatchGuard XCSv device serial number You receive the serial number when you purchase the XCSv virtual device. Your WatchGuard XCSv feature key You receive the feature key when you activate your device on the LiveSecurity web site. WatchGuard XCSv OVF template The file name is xcsv-<version>.ova, where <version> is the XCS version. Download the XCSv OVF template file from the Articles and Software section of the WatchGuard Portal at Installation Overview To complete initial installation you must perform these procedures described in the subsequent sections: 1. In the VMware vsphere client, deploy the XCSv OVF template file to the VMware host. 2. Perform any resource allocation (CPU, memory, disk, network) modifications on the VMware host based on your XCSv edition. 3. Power on the XCSv virtual device. 4. Connect to the XCSv device to run the Setup Wizard. Network Considerations When you deploy the XCSv OVF template to the VMware virtual device, it is initially configured for the Medium Office Edition with three active interfaces. You must map each of these interfaces to a physical destination network on your VMware host. After you configure the XCSv device, you can enable and configure additional XCSv device interfaces or remove interfaces if you need fewer interfaces. The maximum number of interfaces you can enable in VMware is 10. For information about how to add resources to the device, see VMware Virtual Machine Resource Allocation on page 12. Time Synchronization Considerations The WatchGuard XCSv OVF template automatically installs the VMware Tools utility software. VMware Tools is a suite of utilities for managing your virtual device, and includes a time synchronization service that synchronizes with the host system time. This service is disabled by default. We recommend that you use the WatchGuard XCSv NTP settings to configure an NTP server, and keep the VMware Tools time synchronization service disabled. These services must not be enabled and running at the same time. Note The WatchGuard XCSv NTP settings must be configured if you are setting up an XCSv cluster. Setup Guide 7

10 Installation Perform the following steps to install WatchGuard XCSv on a VMware host Install the VMware vsphere Client To install the vsphere client: 1. Launch a web browser on your computer and type the IP address or host name of the VMware host server as the URL in the location bar. 2. To download and install the vsphere Client, click Download vsphere Client. Connect to the VMware Host To connect to the VMware host: 1. Launch the VMware vsphere Client. 2. Type the IP address, User name, and Password for the VMware host, then click Login. 8 WatchGuard XCSv

11 Deploy the XCSv OVF File To create the XCSv virtual device, you must deploy the XCSv OVF template in the vsphere client. 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. In the vsphere client, select File > Deploy OVF Template. 3. Browse to the location where you saved the WatchGuard XCSv OVF template file, xcsv-<version>.ova. Click Next. The XCSv OVF Template Details page appears. 4. Click Next. The End User License Agreement appears. 5. Review the End-User License Agreement. Click Accept. Click Next. The Name and Location page appears. 6. In the Name text box, type a name for this virtual device. Setup Guide 9

12 7. Select a resource pool within which to deploy this template. Click Next. The Disk Format page appears. 8. Select the format to store the virtual disks. We recommend that you select Thick provisioned format to allocate all storage immediately. 9. Click Next. The Network Mapping page appears. 10 WatchGuard XCSv

13 10. In the Destination Networks column, select the networks to map to each network interface. 11. Click Next. The Ready to Complete page appears. 12. Review the settings. Click Back to change any settings, if necessary. 13. Click Finish to deploy the template. The virtual appliance is deployed. This can take a few minutes. The deployed virtual device appears in the vsphere Inventory in the selected resource pool. Setup Guide 11

14 VMware Virtual Machine Resource Allocation The default WatchGuard XCSv OVF template installation is configured for a Medium Office Edition resource environment with two virtual CPUs, 2 GB memory, three network adapters, and 80 GB data disk space. If your feature key is for a different edition, such as Small or Large edition, you must modify your VMware host resources for virtual processors, memory, and disk space to properly support your licensed software edition. For information on recommended resource settings for each XCSv edition, see Recommended Resource Allocation on page 5. Configure Virtual CPUs By default, the XCSv virtual machine is allocated two virtual CPUs. For optimal performance, configure the virtual machine to use the recommended number of CPUs for your XCSv edition. To configure CPU resources: 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. Make sure your XCSv virtual machine is powered off. 3. In the vsphere inventory tree, right click the XCSv virtual machine. 4. Select Edit Settings. 5. In the Hardware list, select CPUs. 6. From the Number of virtual sockets drop-down list, select the number of virtual processors recommended for your XCSv edition. 7. Click OK. Configure Memory Resources By default the XCSv virtual machine is allocated 2 GB of memory. For optimal performance, configure the virtual machine to use the recommended amount of memory for your XCSv edition. To configure memory resources: 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. Make sure your XCSv virtual machine is powered off. 3. In the vsphere inventory tree, right click the XCSv virtual machine. 4. Select Edit Settings. 5. In the Hardware list, select Memory. 6. In the Memory Size text box, type or select the memory size recommended for your XCSv edition. 7. Click OK. Configure Hard Disk Resources By default the XCSv virtual device is allocated two hard drives, a primary fixed OS system disk (Hard Disk 1, 24 GB), and a data disk for messages, logs, reports, and any other data (Hard Disk 2, 80 GB for default XCSv Medium Edition). For optimal disk space allocation, configure the virtual machine to use the recommended amount of disk space for your specific XCSv edition and allow for any requirements for additional data disk space for logs and reports. Caution Do not modify the Hard Disk 1. This disk is a fixed size and contains the OS for the XCSv. 12 WatchGuard XCSv

15 To increase the size of the Hard Disk 2 data disk for other XCSv editions (160 GB Large and 256 GB Large XC): 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. Make sure your XCSv virtual machine is powered off. 3. In the vsphere inventory tree, right click the XCSv virtual machine. 4. Select Edit Settings. 5. In the Hardware list, select Hard disk In the Disk Provisioning section, modify the Provisioned Size setting to the required value (160 GB Large or 256 GB Large XC). 7. Click OK. To decrease the size of the Hard Disk 2 data disk for the XCSv Small Edition, you must remove Hard Disk 2 and add a new hard disk with a recommended size of 40 GB. 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. Make sure your XCSv virtual machine is powered off. 3. In the vsphere inventory tree, right click the XCSv virtual machine. 4. Select Edit Settings. 5. In the Hardware list, select Hard disk Click Remove. 7. Select Remove from virtual machine and delete files from disk. 8. Click OK. 9. Right click the virtual machine, select Edit Settings. 10. Click Add. 11. Select Hard Disk and click Next. 12. Select Create a new virtual disk and click Next. 13. Set the Disk Size to 40 GB. 14. In the Disk Provisioning section, select Thick Provisioned Lazy Zeroed. 15. Select Store with the virtual machine and click Next. 16. In the Advanced Options, leave the default settings and click Next. 17. Click Finish. 18. Click OK. Add Network Adapters When you deployed the XCSv OVF template, you selected networks to map to the XCSv device interfaces that are active by default. To enable other interfaces, you must add network adapters to the XCSv device. To add a network adapter: 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. Make sure your XCSv virtual machine is powered off. 3. In the vsphere inventory tree, right click the XCSv virtual machine. 4. Select Edit Settings. 5. In the Hardware tab, click Add. 6. Select Ethernet Adapter as the type of device you want to add. Click Next. 7. From the Type drop-down list, select the type of virtual network adapter to use. The recommended type, E1000, is selected by default. 8. From the Network label drop-down list, select the name of the virtual network to add. 9. Click Next. Setup Guide 13

16 10. Review the selected options. Click Finish. Repeat these steps for each network adapter you want to add. When you power on the XCSv device the additional network adapter is connected. Start your XCSv Virtual Device 1. In the vsphere Client Inventory tree, select the virtual device. 2. Click the Summary tab. 3. In the Commands section, select Power on. The WatchGuard XCSv virtual device is powered on with factory default settings. 4. Click the Console tab to view the installation process. Note The WatchGuard XCSv performs an automatic installation. Do not interrupt the installation process. 14 WatchGuard XCSv

17 Microsoft Hyper-V Installation Before You Begin To prepare for your installation, make sure you have these items: Hyper-V role on Windows Server 2008 R2 or Windows Server 2012, or stand-alone version of Hyper-V Server 2008 R2 or Hyper-V Server WatchGuard XCSv device serial number You receive the serial number when you purchase the XCSv virtual device. Your WatchGuard XCSv feature key You receive the feature key when you activate your device on the LiveSecurity web site. WatchGuard XCSv Hyper-V package The file name is XCSv-<version>-HyperV.zip where <version> is the XCS version. The file contains a EULA, a README file, and two virtual hard disk (.vhd) files, xcs-1.vhd (system) and xcs-2.vhd (data). Download the XCSv Hyper-V package from the Articles and Software section of the WatchGuard Portal at Installation Overview To complete initial installation you must perform these procedures described in the subsequent sections: 1. In Hyper-V, create your virtual machine for the XCSv software. 2. Perform any resource allocation (Processors, memory, disk, network) modifications on the Hyper-V host based on your XCSv edition. 3. Power on the XCSv virtual machine. 4. Connect to the XCSv virtual machine to run the Setup Wizard. Network Considerations When you deploy the XCSv software to the Hyper-V virtual device, it is initially configured with a single network interface. You must add a network adapter for each XCSv network interface you require. You must map each of these interfaces to a physical destination network on your Hyper-V virtual host. After you configure the XCSv device, you can enable and configure additional XCSv device interfaces or remove interfaces if you need fewer interfaces. The maximum number of interfaces you can enable in Hyper- V is 8. Time Synchronization Considerations The use of the Hyper-V Time synchronization feature is not supported. We recommend you use an NTP server in the XCSv network configuration. WatchGuard XCSv NTP settings must be configured if you are setting up an XCSv cluster. Setup Guide 15

18 Installation Perform the following steps to install WatchGuard XCSv on a Hyper-V host. Create the XCSv Virtual Machine To create the XCSv virtual machine on the Hyper-V host: 1. Extract the contents of the Hyper-V zip file to a suitable location on your Hyper-V host where your virtual hard disks are stored. 2. In Hyper-V Manager, select Action > New > Virtual Machine. 3. Type a Name for your virtual machine and specify a Location. You can use the default location, or select a new location for the virtual machine on your Hyper-V host. 16 WatchGuard XCSv

19 4. Specify the amount of Startup memory to assign to the virtual machine. This value must be a minimum of 2GB (2000 MB) and depends on which XCSv edition you want to install and your available resources. (Small - 2GB, Medium - 2GB, Large - 4GB, Large XC - 8GB). Caution Do not enable the Use Dynamic Memory for this virtual machine option. This option is not supported for XCSv. Setup Guide 17

20 5. From the Connection drop-down list, select Not Connected. Later in the installation you will configure virtual network adapters and map them to the network interfaces on your Hyper-V host. 6. Select the Use an existing virtual hard disk option. Click Browse, then select the location of the xcs-1.vhd file. 18 WatchGuard XCSv

21 7. Click Finish to complete the wizard. Setup Guide 19

22 Hyper-V Virtual Machine Resource Allocation You must now edit the settings of your XCSv virtual machine to configure the resources based on your XCSv edition. 1. In Hyper-V Manager, select your virtual machine, then select Settings. 2. Select Processor, and configure the number of processors based on your XCSv edition. (Small - 1, Medium - 2, Large - 4, Large XC - 8). 3. Select the IDE Controller 0 where the xcs-1.vhd hard drive is located. 20 WatchGuard XCSv

23 4. Select Hard Drive then click Add. Setup Guide 21

24 5. If you want to use the default 80GB size as a data drive for XCSv Medium edition, select Virtual Hard Disk, click Browse, then select the location of the xcs-2.vhd file. You can also define a new drive with the proper size for your specific XCSv edition (Small - 40GB, Medium - 80GB, Large - 160GB, Large XC - 256GB). Caution Do not adjust or delete the xcs-1.vhd hard drive as this is the system disk. 22 WatchGuard XCSv

25 6. Select the default Network Adapter and edit the settings. Connect the adapter to the required network on your virtual host. 7. Click Add Hardware. Setup Guide 23

26 8. Add additional Network Adaptors connected to the required networks on your virtual host. 9. Click OK to apply the settings to the virtual machine. 10. Power on the XCSv virtual machine. For instructions on how to install XCSv, see Install WatchGuard XCSv on page WatchGuard XCSv

27 Install WatchGuard XCSv Default Network Settings The default network settings for the WatchGuard XCSv after installation are: IP address: Netmask: Gateway: If you want to connect to the XCSv device with the default IP address, go to Connect to the Setup Wizard on page 27. You can change the default IP address of the XCSv and assign the IP addresses of your additional network interfaces before you connect to the Setup Wizard. This allows you to assign IP addresses to the XCSv based on the networks already available on your virtual host system. Note The Setup Wizard will skip the first three steps (Introduction, Regional Settings, and Network Configuration) if you modify the default network settings and IP address from the XCSv console. To modify the default IP address of your XCSv before running the Setup Wizard: 1. In the vsphere Client Inventory tree, select the XCSv virtual device. 2. Click the Console tab. 3. Press Enter to display the login screen. 4. Type the default Username and Password. When you access the system for the first time after installation, the default settings are admin for the username, and admin for the password. Setup Guide 25

28 5. On the XCSv console menu, select Admin > Configure Interfaces. You can configure these options: Hostname Type the hostname for the device. For example, if your fully qualified domain name is hostname.example.com, type hostname. Domain Type your domain. For this example, type example.com. Gateway Type the gateway (typically the router) for your network. For this example, type DNS Server Type the IP address of your primary and secondary DNS Name Servers. For this example, type NTP Server Type the IP address or hostname of your primary and secondary NTP servers. For this example, type Select OK. 7. For each network interface, you can configure these options: IP Address Type IP address for this interface. For this example, type Subnet Mask Type the netmask. For this example, type Admin Login Allow administrative access on this interface. You must set this option to ON for the interface you will use to access the Setup Wizard. 8. Select OK. 9. Select Yes to reboot the system. 10. Select Yes to confirm. 26 WatchGuard XCSv

29 Connect to the Setup Wizard Wait at least five minutes for the system to initialize before you try to connect to the WatchGuard XCSv with a web browser. Ping is enabled on the configured network interface. You can ping the IP address of the XCSv to check connectivity before you connect with a web browser. Note We recommend that you clear your web browser cache before you start the Setup Wizard. 1. Launch a web browser on your computer and type the IP address of the WatchGuard XCSv as the URL in the location bar. For example, The login page appears. Note A security certificate notification appears in the browser because the system uses a self-signed certificate. It is safe to ignore the warning (Internet Explorer) or to add a certificate exception (Mozilla Firefox). 2. Type the default Username and Password. When you access the system for the first time after installation, the default settings are admin for the username, and admin for the password. Setup Guide 27

30 3. The Setup Wizard introduction page appears. Click Continue to start the installation. Make sure you register your device serial number with the WatchGuard LiveSecurity web site and receive a feature key before you proceed with the installation process. 4. In the Regional Settings page, configure these options: Time Settings Type the current Time and Date. For the time, use 24-hour format hh:mm:ss. For the date, use this format, YYYY-MM-DD. Time Zone Select the closest city to your location and time zone. Keyboard Select the keyboard layout for your location. 5. Click Continue. 28 WatchGuard XCSv

31 6. On the Networks Settings page, configure the first network interface. You can configure these options: Hostname Type the hostname for the device. For example, if your fully qualified domain name is hostname.example.com, type hostname. Domain Type your domain. For this example, type example.com. Gateway Type the gateway (typically the router) for your network. For this example, type Name Server Type the IP address of your DNS Name Server. For this example, type Name Server 2 Type the IP address of a secondary DNS name server. For this example, type NTP Server Type the IP address or hostname of your NTP server. For this example, type IP Address Type the IP address for this interface. For this example, type Netmask Type the netmask. For this example, type External Proxy Server If your network uses a proxy server to access the Internet, you must set this option to Enabled and enter your external proxy server configuration. The WatchGuard XCSv requires access to the Internet through the proxy server to retrieve licensing information and software updates. If you do not use an external proxy server, leave this option set to Disabled. Setup Guide 29

32 Server Address Type the IP address of your external proxy server. Server Port Type the server port used by the external proxy server. The default is TCP port 80. User Name If your proxy server requires authentication, type the user name to login to the proxy server. Password Type and confirm a password. 7. Click Continue. If you make any network changes, you must restart the device and reconnect to the WatchGuard XCSv with the new IP address you assigned to the network interface. Note Make sure your computer is configured to access the new IP address settings on the WatchGuard XCSv. 8. On the Customer Information page, type the Organization Name and Server Admin . Device alerts and notifications are sent to the Server Admin address. 9. Click Continue. 10. On the Change Password page, type and confirm a new admin password. We recommend that you choose a secure password of at least 8 characters in length and include a mixture of upper and lowercase letters, numbers, and special characters. 11. Click Continue. 30 WatchGuard XCSv

33 12. On the Product Serial page, type your XCSv serial number. Note The serial number cannot be changed after it has been entered and saved. If you enter the wrong serial number or need to enter a different one, you must reinstall the XCSv from the OVF template file. 13. On the Feature Key page, select one of these options to add your feature key: Click Manual Update to manually add a feature key. You must paste your feature key into the text box and click Apply. Click Download to automatically download and apply your feature key from the WatchGuard LiveSecurity service. This option requires an Internet connection and an existing LiveSecurity account. Make sure you can access the Internet if the device is installed behind a network firewall or connects through an external proxy server. Click Enter Feature Key Later to manually add the feature key after the installation. To enter the feature key manually, from the Web UI, select Administration > System > Feature Key. If you encounter errors when you add your feature key, check the following: For Automatic Update: Make sure you have a valid LiveSecurity account and you have registered your device serial number You must have an Internet connection to retrieve your feature key Make sure communications are not blocked by a network firewall For Manual Update: Make sure you cut and paste the entire feature key text The first line must be Serial Number: V2C9xxxxx-xxxx The last line is a long line starting with Signature: Setup Guide 31

34 14. On the Mail Configuration page, enter your mail domain and server details, and the initial status of the WatchGuard XCSv security scanning features. In the Domain text box, type the domain for which the WatchGuard XCSv processes messages. For example, example.com. In the Internal Mail Server text box, type the IP address of the internal mail server that receives and sends mail through the WatchGuard XCSv. The WatchGuard XCSv automatically configures a mail route for the domain and internal mail server you enter on this page. To configure additional domains for mail routing after the installation is complete, from the Web UI, select Configuration > Mail > Routing. The WatchGuard XCSv also automatically configures a Specific Access Pattern to trust your internal mail server address to allow the mail server to relay mail outbound through the WatchGuard XCSv. Mail originating from the internal mail server is also trusted for Anti-Spam processing. To configure Specific Access Patterns after the installation is complete, from the Web UI, select Configuration > Mail > Access. 15. Click Continue. 32 WatchGuard XCSv

35 16. In the Security Settings section of the Mail Configuration page, you can enable or disable Intercept Anti-Spam, Anti-Virus, and the Attachment Control features. If you enable these features in the setup wizard, mail scanning is active when the installation is complete and mail processing is started. This table describes the default Intercept settings when you enable Intercept Anti-Spam: Feature Reject on ReputationAuthority Reputation Reject on infection (ReputationAuthority) Reject connections from dial-ups (ReputationAuthority) Reject on DNSBL Threat Prevention Reject on unknown sender domain Reject on missing sender MX Reject on non FQDN sender Reject on unauth pipelining Reject on missing addresses Reject on missing reverse DNS Default Setting Enabled (Threshold: 90) Enabled Enabled Enabled Enabled Enabled This table describes the default settings for the Intercept Anti-Spam features: Intercept Option Default Setting Certainly Spam Reject (Threshold: 99) Probably Spam Modify Subject Header: [SPAM] (Threshold: 90) Maybe Spam Just Log (Threshold: 60) Decision Strategy Heuristic 1 Spam Rules Enabled Spam Words Enabled Mail Anomalies Enabled DNS/URL Block List Enabled ReputationAuthority Enabled Token Analysis Enabled SPF Enabled DKIM Disabled DomainKeys Enabled Backscatter Disabled 17. Click Continue. Setup Guide 33

36 18. If you have purchased the Web Scanning option, a Web Configuration page appears. From the HTTP/HTTPS drop-down list, enable or disable HTTP/HTTPS scanning. In the Internal Mail Server text box, type the IP address of the internal mail server that receives and sends mail through the WatchGuard XCS. Note The Internal Mail Server field only appears if you did not configure a mail server in the previous step. In the Security Settings section of the Web Configuration page, you can enable or disable URL Categorization, Reputation Enabled Defense, and the Anti-Virus features. If you enable these features in the Installation Wizard, web scanning is active when the installation is complete and message processing is started. If you enable URL Categorization, the feature will not be enabled until after the initial control list is downloaded. 19. Click Continue. 20. From the Messaging System drop-down list, select Enabled to start message traffic processing after the installation is complete. If you select Disabled, you can start message processing manually from Activity > Status > Status/ Utility after the installation is complete. 21. Click Continue. 34 WatchGuard XCSv

37 22. Click Done to complete the installation. This process can take up to a minute to complete. XCSv CPU Performance Settings To make sure the XCSv software is configured properly for the number of CPU cores you have allocated to your virtual machine, you must reboot the system after you complete the setup wizard. This reboot is required to allow the XCSv to adjust its CPU performance settings according to your configuration to provide optimal performance. To reboot the XCSv, from the Web UI, select Administration > System > Reboot & Shutdown, then click Reboot. Update Anti-Virus Pattern Files If licensed, the Anti-Virus service is automatically enabled and started. After the initial installation of the WatchGuard XCSv, it may take up to the default of one hour to update your Anti-Virus pattern files to the most recent version. We recommend you update your pattern files immediately after installation. To update your pattern files: 1. Select Security > Anti-Virus > Anti-Virus. 2. Go to the Virus Pattern Files section. 3. Click Get Pattern Now. Setup Guide 35

38 Cluster Configuration Clustering provides a highly scalable, redundant messaging security infrastructure that enables two or more WatchGuard XCSv virtual devices to act as a single logical unit for processing messages for redundancy and high availability benefits. When you configure multiple XCSv virtual devices in a cluster, message traffic flow is never interrupted because of individual device failures. Cluster Network The XCSv virtual devices participating in the cluster communicate through a network interface connected to a separate network called the Cluster Network. The Cluster Network is a dedicated, secure subnet, and the devices communicate clustering information with each other through this network. You can add or remove devices from the cluster network without interruption to message processing. XCSv Cluster Deployment To set up multiple XCSv virtual devices in a cluster, you must configure a dedicated virtual network switch on the virtual host system to ensure that no data can leak to other virtual machines running on your virtual host. This virtual switch must be mapped to actual physical network interfaces on the virtual host system if you are clustering with XCSv devices on another physical virtual host. We recommend that if you set up multiple XCSv devices in a cluster, you should install your XCSv virtual devices on separate virtual hosts for hardware and software redundancy in the event an issue affects the virtual host. 36 WatchGuard XCSv

39 If your clustered XCSv devices are hosted on the same virtual host system, the virtual switch does not have to be mapped to physical network interfaces and you can configure the switch as an internal logical switch. Note If you install clustered XCSv devices on the same virtual host, this configuration only provides software redundancy in the event one of the XCSv virtual devices fails. If a hardware or software issue affects the virtual host, your entire XCSv cluster will be affected. Setup Guide 37

40 Add a Virtual Switch on the Virtual Host These sections describe how to add a virtual switch to a VMware or Hyper-V virtual host. Add a Virtual Switch on the VMware Host To add a virtual switch on your VMware host: 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. In the vsphere inventory tree, select your XCSv virtual machine. 3. Select the Configuration tab. 4. In the Hardware section, click Networking. 5. Click Add Networking... The Add Network wizard appears. 6. Select Virtual Machine, then click Next. 7. Select a physical network adapter to use with the virtual switch, or deselect all adapters to create a logical virtual switch. 8. Click Next. 9. In the Network Label text box, type a name for this switch network. For example, type Cluster Network. 10. Click Next, then click Finish. 38 WatchGuard XCSv

41 Add a Virtual Switch on Hyper-V To add a virtual switch on your Hyper-V host: 1. Launch Hyper-V Manager. 2. Select Virtual Switch Manager. 3. Select New Virtual Network Switch. 4. Select Private, then click Create Virtual Switch. 5. Type a name for the virtual switch. For example, type Cluster. 6. Click OK to apply the settings to virtual machine. Setup Guide 39

42 Assign an XCSv Network Interface to the Virtual Cluster Switch You must now map a network interface from the XCSv to the virtual cluster switch you created in the previous step. Assign a Cluster Interface on VMware To assign a cluster interface to a virtual switch on VMware: 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. Make sure your XCSv virtual machine is powered off. 3. In the vsphere inventory tree, select your XCSv virtual machine. 4. Select Edit Settings. 5. Select the Hardware tab. 6. Select the network adapter you want to use for the cluster. 7. From the Network Label: drop-down list, select Cluster Network, or the name you assigned to the cluster network in the previous section. 8. Click OK to apply the settings to the virtual machine. 40 WatchGuard XCSv

43 Assign a Cluster Interface on Hyper-V To assign a cluster interface to a virtual switch on Hyper-V: 1. Launch Hyper-V Manager. 2. Select your virtual machine, and click Settings. 3. Select the Network Adapter that you want to connect to the cluster switch. 4. From the Virtual Switch drop-down list, select the cluster virtual switch you created in the previous step. 5. Click OK to apply the settings to the virtual machine. Setup Guide 41

44 Configure Clustering on an XCSv Virtual Device When you have setup the virtual switch for use with your cluster network, you can now enable clustering and configure a network interface on each XCSv virtual device to connect to this cluster network. To configure clustering on each XCSv device participating in the cluster: 1. Log in to the XCSv Web UI. 2. Select Configuration > Network > Interfaces. 3. Select the network interface connected to the cluster network. This interface must not be configured with an IP address. The interface is automatically configured for exclusive use on the cluster network. 4. From the Interface Mode drop-down list, select Cluster. Note Make sure that an NTP time server is configured on each device, and add additional NTP servers for redundancy. You cannot enable clustering until you configure an NTP server. The time server synchronizes all cluster devices from a common time source. 5. Click Apply. You must restart the system. More more details on cluster configuration, see the current WatchGuard XCS Help or User Guide. 42 WatchGuard XCSv

45 Resource Monitoring Your virtual host system may host other virtual machines in addition to the WatchGuard XCSv. To ensure that your virtual host resources are properly allocated, you must regularly monitor the resource usage and performance of your virtual host system and your XCSv virtual machine. Resource Monitoring on VMware To monitor the resource usage of your VMware host and virtual machines: 1. Launch the vsphere client and log in to the VMware host with administrator credentials. 2. In the vsphere inventory tree, select your VMware host system at the top of the list. 3. Select the Virtual Machines tab. You can view the disk space, CPU usage, and memory utilization of each virtual machine hosted on your VMware system. 4. Select the Resource Allocation tab. 5. You can switch between CPU, Memory, and Storage view for a more detailed examination of the resources used by your virtual machines on the VMware host. Setup Guide 43

46 6. Select the Performance tab for a customized chart view of the VMware host performance. 7. In the vsphere inventory tree, select your XCSv virtual machine. 8. Select the Resource Allocation tab. You can examine the resources in use specifically by the XCSv virtual machine. 9. Select the Performance tab for a customized chart view of the XCSv virtual machine performance. 44 WatchGuard XCSv

47 Resource Monitoring on Hyper-V To monitor the resource usage of your Hyper-V host and virtual machines: 1. Launch Hyper-V Manager. 2. From the Virtual Machines list, you can view the current status of the virtual machine, the CPU usage, assigned memory, and system uptime. 3. Select a specific virtual machine. In the Summary section, you can view information including an overall summary of the virtual machine, the original and assigned memory usage, and networking status. Setup Guide 45

48 46 WatchGuard XCSv

Configuration Example

Configuration Example Configuration Example Use Public IP Addresses Behind an XTM Device Example configuration files created with WSM v11.7.2 Revised 3/22/2013 Use Case There are several reasons to use publicly routable IP

More information

F-Secure Messaging Security Gateway. Deployment Guide

F-Secure Messaging Security Gateway. Deployment Guide F-Secure Messaging Security Gateway Deployment Guide TOC F-Secure Messaging Security Gateway Contents Chapter 1: Deploying F-Secure Messaging Security Gateway...3 1.1 The typical product deployment model...4

More information

Virtual Appliance Setup Guide

Virtual Appliance Setup Guide Virtual Appliance Setup Guide 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property of their respective

More information

Configuration Example

Configuration Example Configuration Example Set Up a Public Web Server Behind a Firebox Example configuration files created with WSM v11.10.1 Revised 7/21/2015 Use Case In this configuration example, an organization wants to

More information

Barracuda Message Archiver Vx Deployment. Whitepaper

Barracuda Message Archiver Vx Deployment. Whitepaper Barracuda Message Archiver Vx Deployment Whitepaper Document Scope This document provides guidance on designing and deploying Barracuda Message Archiver Vx on VMware vsphere Document Scope, and Microsoft

More information

Configuration Example

Configuration Example Configuration Example Use WatchGuard Application Control with Your Existing Firewall Example configuration files created with WSM v11.10.1 Revised 7/21/2015 Use Case An organization wants to block the

More information

RSA Authentication Manager 8.1 Virtual Appliance Getting Started

RSA Authentication Manager 8.1 Virtual Appliance Getting Started RSA Authentication Manager 8.1 Virtual Appliance Getting Started Thank you for purchasing RSA Authentication Manager 8.1, the world s leading two-factor authentication solution. This document provides

More information

Virtual Web Appliance Setup Guide

Virtual Web Appliance Setup Guide Virtual Web Appliance Setup Guide 2 Sophos Installing a Virtual Appliance Installing a Virtual Appliance This guide describes the procedures for installing a Virtual Web Appliance. If you are installing

More information

Configuration Example

Configuration Example Configuration Example Use NAT for Public Access to Servers with Private IP Addresses on the Private Network Example configuration files created with WSM v11.7.2 Revised 5/10/2013 Use Case In this use case,

More information

Virtual Appliance Setup Guide

Virtual Appliance Setup Guide The Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda Web Application Firewall hardware appliance. It is designed for easy deployment on

More information

Virtual Managment Appliance Setup Guide

Virtual Managment Appliance Setup Guide Virtual Managment Appliance Setup Guide 2 Sophos Installing a Virtual Appliance Installing a Virtual Appliance As an alternative to the hardware-based version of the Sophos Web Appliance, you can deploy

More information

F-Secure Internet Gatekeeper Virtual Appliance

F-Secure Internet Gatekeeper Virtual Appliance F-Secure Internet Gatekeeper Virtual Appliance F-Secure Internet Gatekeeper Virtual Appliance TOC 2 Contents Chapter 1: Welcome to F-Secure Internet Gatekeeper Virtual Appliance.3 Chapter 2: Deployment...4

More information

Configuration Information

Configuration Information This chapter describes some basic Email Security Gateway configuration settings, some of which can be set in the first-time Configuration Wizard. Other topics covered include Email Security interface navigation,

More information

Barracuda Message Archiver Vx Deployment. Whitepaper

Barracuda Message Archiver Vx Deployment. Whitepaper Barracuda Message Archiver Vx Deployment Whitepaper Document Scope This document provides guidance on designing and deploying Barracuda Message Archiver Vx on VMware vsphere Document Scope, and Microsoft

More information

CommandCenter Secure Gateway

CommandCenter Secure Gateway CommandCenter Secure Gateway Quick Setup Guide for CC-SG Virtual Appliance - VMware, XEN, HyperV This Quick Setup Guide explains how to install and configure the CommandCenter Secure Gateway. For additional

More information

WatchGuard Dimension v1.1 Update 1 Release Notes

WatchGuard Dimension v1.1 Update 1 Release Notes WatchGuard Dimension v1.1 Update 1 Release Notes Build Number 442674 Revision Date March 25, 2014 WatchGuard Dimension is the next-generation cloud-ready visibility solution for our Unified Threat Management

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.7.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

PHD Virtual Backup for Hyper-V

PHD Virtual Backup for Hyper-V PHD Virtual Backup for Hyper-V version 7.0 Installation & Getting Started Guide Document Release Date: December 18, 2013 www.phdvirtual.com PHDVB v7 for Hyper-V Legal Notices PHD Virtual Backup for Hyper-V

More information

RealPresence Platform Director

RealPresence Platform Director RealPresence CloudAXIS Suite Administrators Guide Software 1.3.1 GETTING STARTED GUIDE Software 2.0 June 2015 3725-66012-001B RealPresence Platform Director Polycom, Inc. 1 RealPresence Platform Director

More information

Deployment and Configuration Guide

Deployment and Configuration Guide vcenter Operations Manager 5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions

More information

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual

Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual Hillstone StoneOS User Manual Hillstone Unified Intelligence Firewall Installation Manual www.hillstonenet.com Preface Conventions Content This document follows the conventions below: CLI Tip: provides

More information

Installing and Configuring vcenter Support Assistant

Installing and Configuring vcenter Support Assistant Installing and Configuring vcenter Support Assistant vcenter Support Assistant 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced

More information

Server Software Installation Guide

Server Software Installation Guide Server Software Installation Guide This guide provides information on...... The architecture model for GO!Enterprise MDM system setup... Hardware and supporting software requirements for GO!Enterprise

More information

Sophos for Microsoft SharePoint startup guide

Sophos for Microsoft SharePoint startup guide Sophos for Microsoft SharePoint startup guide Product version: 2.0 Document date: March 2011 Contents 1 About this guide...3 2 About Sophos for Microsoft SharePoint...3 3 System requirements...3 4 Planning

More information

SonicWALL SRA Virtual Appliance Getting Started Guide

SonicWALL SRA Virtual Appliance Getting Started Guide COMPREHENSIVE INTERNET SECURITY SonicWALL Secure Remote Access Appliances SonicWALL SRA Virtual Appliance Getting Started Guide SonicWALL SRA Virtual Appliance5.0 Getting Started Guide This Getting Started

More information

WatchGuard Certified Training Partner (WCTP) Program

WatchGuard Certified Training Partner (WCTP) Program WatchGuard Certified Training Partner (WCTP) Program Revised: April 2012 Overview The WCTP program is a mutually beneficial partnership between WatchGuard and our most highly qualified business partners.

More information

provides several new features and enhancements, and resolves several issues reported by WatchGuard customers.

provides several new features and enhancements, and resolves several issues reported by WatchGuard customers. WatchGuard XCS v10.0 Update 1 Release Notes WatchGuard XCS Build 140312 Revision Date 11 November, 2014 Introduction WatchGuard is pleased to announce the release of WatchGuard XCS v10.0 Update 1. This

More information

F-SECURE MESSAGING SECURITY GATEWAY

F-SECURE MESSAGING SECURITY GATEWAY F-SECURE MESSAGING SECURITY GATEWAY DEFAULT SETUP GUIDE This guide describes how to set up and configure the F-Secure Messaging Security Gateway appliance in a basic e-mail server environment. AN EXAMPLE

More information

GX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER

GX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER Quick Start Guide GX-V VIRTUAL GMS SERVER Microsoft Hyper-V Hypervisor 2012 Silver Peak Systems, Inc. Before You Begin Windows 2008 server installed and Hyper-V is running Hyper-V management software is

More information

SevOne NMS Download Installation and Implementation Guide

SevOne NMS Download Installation and Implementation Guide SevOne NMS Download Installation and Implementation Guide 5.3.X 530 V0002 Contents 1. Get Started... 3 2. SevOne Download Installation... 6 3. Appliance Network Configuration... 9 4. Install License and

More information

EMC Data Domain Management Center

EMC Data Domain Management Center EMC Data Domain Management Center Version 1.1 Initial Configuration Guide 302-000-071 REV 04 Copyright 2012-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes

More information

Installing and Configuring vcloud Connector

Installing and Configuring vcloud Connector Installing and Configuring vcloud Connector vcloud Connector 2.0.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

Getting Started Guide

Getting Started Guide Getting Started Guide Sophos Firewall Virtual Appliance Document Date: November 2015 November 2015 Page 1 of 20 Contents Preface...3 Minimum Hardware Requirement...3 Installation Procedure...3 Configuring

More information

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing

More information

Unitrends Virtual Backup Installation Guide Version 8.0

Unitrends Virtual Backup Installation Guide Version 8.0 Unitrends Virtual Backup Installation Guide Version 8.0 Release June 2014 7 Technology Circle, Suite 100 Columbia, SC 29203 Phone: 803.454.0300 Contents Chapter 1 Getting Started... 1 Version 8 Architecture...

More information

Configuration Example

Configuration Example Configuration Example BOVPN Virtual Interface Load Balancing with OSPF Example configuration files created with WSM v11.10 Revised 5/22/2015 Use Case In this configuration example, an organization has

More information

Getting Started with ESXi Embedded

Getting Started with ESXi Embedded ESXi 4.1 Embedded vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

Virtual Appliance Setup Guide

Virtual Appliance Setup Guide The Barracuda SSL VPN Vx Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda SSL VPN hardware appliance. It is designed for easy deployment

More information

VMware Identity Manager Connector Installation and Configuration

VMware Identity Manager Connector Installation and Configuration VMware Identity Manager Connector Installation and Configuration VMware Identity Manager This document supports the version of each product listed and supports all subsequent versions until the document

More information

Installing and Using the vnios Trial

Installing and Using the vnios Trial Installing and Using the vnios Trial The vnios Trial is a software package designed for efficient evaluation of the Infoblox vnios appliance platform. Providing the complete suite of DNS, DHCP and IPAM

More information

Product Version 1.0 Document Version 1.0-B

Product Version 1.0 Document Version 1.0-B VidyoDashboard Installation Guide Product Version 1.0 Document Version 1.0-B Table of Contents 1. Overview... 3 About This Guide... 3 Prerequisites... 3 2. Installing VidyoDashboard... 5 Installing the

More information

Unified Threat Management

Unified Threat Management Unified Threat Management QUICK START GUIDE CR35iNG Appliance Document Version: PL QSG 35iNG/96000-10.04.5.0.007/250121014 DEFAULTS Default IP addresses Ethernet Port IP Address Zone A 172.16.16.16/255.255.255.0

More information

How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall

How To Set Up A Firewall Enterprise, Multi Firewall Edition And Virtual Firewall Quick Start Guide McAfee Firewall Enterprise, Multi-Firewall Edition model S7032 This quick start guide provides high-level instructions for setting up McAfee Firewall Enterprise, Multi-Firewall Edition

More information

Polycom RealPresence Resource Manager System Getting Started Guide

Polycom RealPresence Resource Manager System Getting Started Guide [Type the document title] Polycom RealPresence Resource Manager System Getting Started Guide 8.0 August 2013 3725-72102-001B Polycom Document Title 1 Trademark Information POLYCOM and the names and marks

More information

Configuration Information

Configuration Information Configuration Information Email Security Gateway Version 7.7 This chapter describes some basic Email Security Gateway configuration settings, some of which can be set in the first-time Configuration Wizard.

More information

A Guide to New Features in Propalms OneGate 4.0

A Guide to New Features in Propalms OneGate 4.0 A Guide to New Features in Propalms OneGate 4.0 Propalms Ltd. Published April 2013 Overview This document covers the new features, enhancements and changes introduced in Propalms OneGate 4.0 Server (previously

More information

Managing Multi-Hypervisor Environments with vcenter Server

Managing Multi-Hypervisor Environments with vcenter Server Managing Multi-Hypervisor Environments with vcenter Server vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.0 This document supports the version of each product listed and supports all subsequent

More information

WatchGuard SSL Web UI 3.2 User Guide

WatchGuard SSL Web UI 3.2 User Guide WatchGuard SSL Web UI 3.2 User Guide WatchGuard SSL Web UI 3.2 User Guide WatchGuard SSL 100 WatchGuard SSL 560 About this User Guide The WatchGuard SSL Web UI User Guide is updated with each major product

More information

WatchGuard Training. Introduction to WatchGuard Dimension

WatchGuard Training. Introduction to WatchGuard Dimension WatchGuard Training Introduction to WatchGuard Dimension Introduction to WatchGuard Dimension What is WatchGuard Dimension? Deploy WatchGuard Dimension Configure WatchGuard Dimension Use WatchGuard Dimension

More information

WatchGuard SSL Web UI 3.1.3 User Guide

WatchGuard SSL Web UI 3.1.3 User Guide WatchGuard SSL Web UI 3.1.3 User Guide WatchGuard SSL Web UI 3.1.3 User Guide WatchGuard SSL 100 WatchGuard SSL 560 About this User Guide The WatchGuard SSL Web UI User Guide is updated with each major

More information

Configuration Guide. Websense Web Security Solutions Version 7.8.1

Configuration Guide. Websense Web Security Solutions Version 7.8.1 Websense Web Security Solutions Version 7.8.1 To help you make the transition to Websense Web Security or Web Security Gateway, this guide covers the basic steps involved in setting up your new solution

More information

Rally Installation Guide

Rally Installation Guide Rally Installation Guide Rally On-Premises release 2015.1 rallysupport@rallydev.com www.rallydev.com Version 2015.1 Table of Contents Overview... 3 Server requirements... 3 Browser requirements... 3 Access

More information

User Guide. Cloud Gateway Software Device

User Guide. Cloud Gateway Software Device User Guide Cloud Gateway Software Device This document is designed to provide information about the first time configuration and administrator use of the Cloud Gateway (web filtering device software).

More information

Cyberoam Virtual Security Appliance - Installation Guide for VMware ESX/ESXi. Version 10

Cyberoam Virtual Security Appliance - Installation Guide for VMware ESX/ESXi. Version 10 Cyberoam Virtual Security Appliance - Installation Guide for VMware ESX/ESXi Version 10 Document Version 10.6.2-16/04/2015 Contents Preface... 4 Base Configuration... 4 Installation Procedure... 4 Cyberoam

More information

Configuration Example

Configuration Example Configuration Example Centralized Branch Office VPN Architecture (Hub & Spoke) Example configuration files created with WSM v11.10.1 Revised 7/24/2015 Use Case In this configuration example, an organization

More information

Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks

Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks Set Up Panorama Palo Alto Networks Panorama Administrator s Guide Version 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara, CA 95054 www.paloaltonetworks.com/company/contact-us

More information

OnCommand Performance Manager 1.1

OnCommand Performance Manager 1.1 OnCommand Performance Manager 1.1 Installation and Administration Guide For VMware Virtual Appliances NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408)

More information

Core Protection for Virtual Machines 1

Core Protection for Virtual Machines 1 Core Protection for Virtual Machines 1 Comprehensive Threat Protection for Virtual Environments. Installation Guide e Endpoint Security Trend Micro Incorporated reserves the right to make changes to this

More information

Cyberoam Virtual Security Appliance - Installation Guide for XenServer. Version 10

Cyberoam Virtual Security Appliance - Installation Guide for XenServer. Version 10 Cyberoam Virtual Security Appliance - Installation Guide for XenServer Version 10 Document Version 10.6.1-01/07/2014 Contents Preface... 4 Base Configuration... 4 Installation Procedure... 4 Cyberoam Virtual

More information

RSA Authentication Manager 8.1 Setup and Configuration Guide. Revision 2

RSA Authentication Manager 8.1 Setup and Configuration Guide. Revision 2 RSA Authentication Manager 8.1 Setup and Configuration Guide Revision 2 Contact Information Go to the RSA corporate website for regional Customer Support telephone and fax numbers: www.emc.com/domains/rsa/index.htm

More information

Web Application Firewall

Web Application Firewall Web Application Firewall Getting Started Guide August 3, 2015 Copyright 2014-2015 by Qualys, Inc. All Rights Reserved. Qualys and the Qualys logo are registered trademarks of Qualys, Inc. All other trademarks

More information

Veeam Backup Enterprise Manager. Version 7.0

Veeam Backup Enterprise Manager. Version 7.0 Veeam Backup Enterprise Manager Version 7.0 User Guide August, 2013 2013 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may

More information

WatchGuard Certified Training Partner (WCTP) Program

WatchGuard Certified Training Partner (WCTP) Program WatchGuard Certified Training Partner (WCTP) Program Revised: July 2010 Overview The WCTP program is a mutually beneficial partnership between WatchGuard and our most highly qualified business partners.

More information

VMware vcenter Log Insight Getting Started Guide

VMware vcenter Log Insight Getting Started Guide VMware vcenter Log Insight Getting Started Guide vcenter Log Insight 1.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by

More information

DOWNTIME CAN SPELL DISASTER

DOWNTIME CAN SPELL DISASTER DOWNTIME CAN SPELL DISASTER Technical Brief Ensure Network Uptime: High Availability with XTM FireCluster August 2010 Network downtime is expensive for businesses in today s 24/7 global economy. Any malfunctions

More information

Altor Virtual Network Security Analyzer v1.0 Installation Guide

Altor Virtual Network Security Analyzer v1.0 Installation Guide Altor Virtual Network Security Analyzer v1.0 Installation Guide The Altor Virtual Network Security Analyzer (VNSA) application is deployed as Virtual Appliance running on VMware ESX servers. A single Altor

More information

BaseManager & BACnet Manager VM Server Configuration Guide

BaseManager & BACnet Manager VM Server Configuration Guide BaseManager & BACnet Manager VM Server Configuration Guide For Self-Hosted BaseManager & BACnet Manager Servers Deployed as Virtual Machines August 27, 2015 Customer Service 1-866-294-5847 i Baseline Inc.

More information

Hyper-V Server 2008 Setup and Configuration Tool Guide

Hyper-V Server 2008 Setup and Configuration Tool Guide Hyper-V Server 2008 Setup and Configuration Tool Guide Microsoft Corporation Published: October 2008 Author: Cynthia Nottingham Abstract This guide will help you set up and configure Microsoft Hyper-V

More information

GRAVITYZONE HERE. Deployment Guide VLE Environment

GRAVITYZONE HERE. Deployment Guide VLE Environment GRAVITYZONE HERE Deployment Guide VLE Environment LEGAL NOTICE All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including

More information

1 You will need the following items to get started:

1 You will need the following items to get started: QUICKSTART GUIDE 1 Getting Started You will need the following items to get started: A desktop or laptop computer Two ethernet cables (one ethernet cable is shipped with the _ Blocker, and you must provide

More information

Storage Sync for Hyper-V. Installation Guide for Microsoft Hyper-V

Storage Sync for Hyper-V. Installation Guide for Microsoft Hyper-V Installation Guide for Microsoft Hyper-V Egnyte Inc. 1890 N. Shoreline Blvd. Mountain View, CA 94043, USA Phone: 877-7EGNYTE (877-734-6983) www.egnyte.com 2013 by Egnyte Inc. All rights reserved. Revised

More information

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.0 July 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing Disaster Recovery Version 7.0 July

More information

Virtual Appliances. Virtual Appliances: Setup Guide for Umbrella on VMWare and Hyper-V. Virtual Appliance Setup Guide for Umbrella Page 1

Virtual Appliances. Virtual Appliances: Setup Guide for Umbrella on VMWare and Hyper-V. Virtual Appliance Setup Guide for Umbrella Page 1 Virtual Appliances Virtual Appliances: Setup Guide for Umbrella on VMWare and Hyper-V Virtual Appliance Setup Guide for Umbrella Page 1 Table of Contents Overview... 3 Prerequisites... 4 Virtualized Server

More information

Configuration Example

Configuration Example Configuration Example Use a Branch Office VPN for Failover From a Private Network Link Example configuration files created with WSM v11.10.1 Revised 7/22/2015 Use Case In this configuration example, an

More information

Backup & Disaster Recovery Appliance User Guide

Backup & Disaster Recovery Appliance User Guide Built on the Intel Hybrid Cloud Platform Backup & Disaster Recovery Appliance User Guide Order Number: G68664-001 Rev 1.0 June 22, 2012 Contents Registering the BDR Appliance... 4 Step 1: Register the

More information

Installing GFI MailSecurity

Installing GFI MailSecurity Installing GFI MailSecurity Introduction This chapter explains how to install and configure GFI MailSecurity. You can install GFI MailSecurity directly on your mail server or you can choose to install

More information

Symantec Messaging Gateway 10.0 Installation Guide. powered by Brightmail

Symantec Messaging Gateway 10.0 Installation Guide. powered by Brightmail Symantec Messaging Gateway 10.0 Installation Guide powered by Brightmail The software described in this book is furnished under a license agreement and may be used only in accordance with the terms of

More information

Installing and Configuring vcenter Multi-Hypervisor Manager

Installing and Configuring vcenter Multi-Hypervisor Manager Installing and Configuring vcenter Multi-Hypervisor Manager vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.1 This document supports the version of each product listed and supports all subsequent

More information

Configuring PA Firewalls for a Layer 3 Deployment

Configuring PA Firewalls for a Layer 3 Deployment Configuring PA Firewalls for a Layer 3 Deployment Configuring PAN Firewalls for a Layer 3 Deployment Configuration Guide January 2009 Introduction The following document provides detailed step-by-step

More information

VMware vcenter Support Assistant 5.1.1

VMware vcenter Support Assistant 5.1.1 VMware vcenter.ga September 25, 2013 GA Last updated: September 24, 2013 Check for additions and updates to these release notes. RELEASE NOTES What s in the Release Notes The release notes cover the following

More information

How to Test Out Backup & Replication 6.5 for Hyper-V

How to Test Out Backup & Replication 6.5 for Hyper-V How to Test Out Backup & Replication 6.5 for Hyper-V Mike Resseler May, 2013 2013 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication

More information

eprism Email Security Suite

eprism Email Security Suite Guide eprism 2505 eprism Email Security Suite 800-782-3762 www.edgewave.com 2001 2012 EdgeWave. All rights reserved. The EdgeWave logo is a trademark of EdgeWave Inc. All other trademarks and registered

More information

Quick Start Guide. for Installing vnios Software on. VMware Platforms

Quick Start Guide. for Installing vnios Software on. VMware Platforms Quick Start Guide for Installing vnios Software on VMware Platforms Copyright Statements 2010, Infoblox Inc. All rights reserved. The contents of this document may not be copied or duplicated in any form,

More information

SILVER PEAK ACCELERATION WITH EMC VSPEX PRIVATE CLOUD WITH RECOVERPOINT FOR VMWARE VSPHERE

SILVER PEAK ACCELERATION WITH EMC VSPEX PRIVATE CLOUD WITH RECOVERPOINT FOR VMWARE VSPHERE VSPEX IMPLEMENTATION GUIDE SILVER PEAK ACCELERATION WITH EMC VSPEX PRIVATE CLOUD WITH RECOVERPOINT FOR VMWARE VSPHERE Silver Peak Abstract This Implementation Guide describes the deployment of Silver Peak

More information

vrealize Air Compliance OVA Installation and Deployment Guide

vrealize Air Compliance OVA Installation and Deployment Guide vrealize Air Compliance OVA Installation and Deployment Guide 14 July 2015 vrealize Air Compliance This document supports the version of each product listed and supports all subsequent versions until the

More information

QUICK START GUIDE. Cisco C170 Email Security Appliance

QUICK START GUIDE. Cisco C170 Email Security Appliance 1 0 0 1 QUICK START GUIDE Email Security Appliance Cisco C170 303357 Cisco C170 Email Security Appliance 1 Welcome 2 Before You Begin 3 Document Network Settings 4 Plan the Installation 5 Install the Appliance

More information

CYAN SECURE WEB APPLIANCE. User interface manual

CYAN SECURE WEB APPLIANCE. User interface manual CYAN SECURE WEB APPLIANCE User interface manual Jun. 13, 2008 Applies to: CYAN Secure Web 1.4 and above Contents 1 Log in...3 2 Status...3 2.1 Status / System...3 2.2 Status / Network...4 Status / Network

More information

Microsoft Hyper-V Server 2008 R2 Getting Started Guide

Microsoft Hyper-V Server 2008 R2 Getting Started Guide Microsoft Hyper-V Server 2008 R2 Getting Started Guide Microsoft Corporation Published: July 2009 Abstract This guide helps you get started with Microsoft Hyper-V Server 2008 R2 by providing information

More information

Clearswift SECURE Exchange Gateway Installation & Setup Guide. Version 1.0

Clearswift SECURE Exchange Gateway Installation & Setup Guide. Version 1.0 Clearswift SECURE Exchange Gateway Installation & Setup Guide Version 1.0 Copyright Revision 1.0, December, 2013 Published by Clearswift Ltd. 1995 2013 Clearswift Ltd. All rights reserved. The materials

More information

GlobalSCAPE DMZ Gateway, v1. User Guide

GlobalSCAPE DMZ Gateway, v1. User Guide GlobalSCAPE DMZ Gateway, v1 User Guide GlobalSCAPE, Inc. (GSB) Address: 4500 Lockhill-Selma Road, Suite 150 San Antonio, TX (USA) 78249 Sales: (210) 308-8267 Sales (Toll Free): (800) 290-5054 Technical

More information

Release Notes for Websense Email Security v7.2

Release Notes for Websense Email Security v7.2 Release Notes for Websense Email Security v7.2 Websense Email Security version 7.2 is a feature release that includes support for Windows Server 2008 as well as support for Microsoft SQL Server 2008. Version

More information

Installing, Uninstalling, and Upgrading Service Monitor

Installing, Uninstalling, and Upgrading Service Monitor CHAPTER 2 Installing, Uninstalling, and Upgrading Service Monitor This section contains the following topics: Preparing to Install Service Monitor, page 2-1 Installing Cisco Unified Service Monitor, page

More information

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client.

The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client. WatchGuard SSL v3.2 Release Notes Supported Devices SSL 100 and 560 WatchGuard SSL OS Build 355419 Revision Date January 28, 2013 Introduction WatchGuard is pleased to announce the release of WatchGuard

More information

Enterprise Manager. Version 6.2. Installation Guide

Enterprise Manager. Version 6.2. Installation Guide Enterprise Manager Version 6.2 Installation Guide Enterprise Manager 6.2 Installation Guide Document Number 680-028-014 Revision Date Description A August 2012 Initial release to support version 6.2.1

More information

Extreme Control Center, NAC, and Purview Virtual Appliance Installation Guide

Extreme Control Center, NAC, and Purview Virtual Appliance Installation Guide Extreme Control Center, NAC, and Purview Virtual Appliance Installation Guide 9034968 Published April 2016 Copyright 2016 All rights reserved. Legal Notice Extreme Networks, Inc. reserves the right to

More information

E-MAIL AND SERVER SECURITY

E-MAIL AND SERVER SECURITY E-MAIL AND SERVER SECURITY DEPLOYMENT GUIDE 1 E-MAIL AND SERVER SECURITY Deployment Guide 2 CONTENTS 1. Overview 3 1.1 How the product works 3 1.2 Product contents 4 2. Deployment scenarios 5 2.1 Stand-alone

More information

E-MAIL AND SERVER SECURITY

E-MAIL AND SERVER SECURITY E-MAIL AND SERVER SECURITY DEPLOYMENT GUIDE 1 E-MAIL AND SERVER SECURITY Deployment Guide 2 CONTENTS 1. Overview 3 2. Deployment scenarios 5 2.1 Stand-alone server 5 2.2 Deploying the product with F-Secure

More information

Installation Guide for Pulse on Windows Server 2012

Installation Guide for Pulse on Windows Server 2012 MadCap Software Installation Guide for Pulse on Windows Server 2012 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software

More information

Quick Setup Guide. 2 System requirements and licensing. 2011 Kerio Technologies s.r.o. All rights reserved.

Quick Setup Guide. 2 System requirements and licensing. 2011 Kerio Technologies s.r.o. All rights reserved. Kerio Control VMware Virtual Appliance Quick Setup Guide 2011 Kerio Technologies s.r.o. All rights reserved. This document provides detailed description on installation and basic configuration of the Kerio

More information

CommandCenter Secure Gateway

CommandCenter Secure Gateway CommandCenter Secure Gateway Quick Setup Guide for CC-SG Virtual Appliance and lmadmin License Server Management This Quick Setup Guide explains how to install and configure the CommandCenter Secure Gateway.

More information