1 ENERGY SAVING IN LIGHTING FIELD Automatic System HYBRID CONTROL GEAR HPSV/MH LAMPS: W LAMPS.. pag. 5 ELECTRONIC CONTROL GEAR HPSV/MH LAMPS: W LAMPS.. pag. 13 ELECTRONIC CONTROL GEAR Cosmopolis LAMPS: W LAMPS HID ENERGY SAVING PROGRAM ( UK )

2 INTRODUCTION The need to reduce pollution and costs of public spending is increasingly on the agenda and to that end, the whole world is developing energy solutions that lead to these results. In the segment illumination light sources that exist, while ensuring optimum levels of brightness, enabling significant energy savings. The lamps that currently meet these requirements are classified as a gas discharge, and in particular lamps are called high pressure sodium vapor (HPSV) and metal halide (MH). These lamps are joining the types LED. Currently much of the Italian public lighting uses mercury vapor light source and a first step towards saving energy would be to replace them with other sources more efficiently. This replacement bring, besides the reduction in consumption, the following benefits: Reduction of CO2 emissions in the environment (saving 1 kwh = 0.5 kg CO2 savings), this point is critical to public support for the attainment of the goals of reducing greenhouse gas emissions, as defined in climate energy package EEC ; Reduction in electricity costs; Similar economic benefits and environmental protection are achieved feeding sources HPSV and MH lamps with dimming systems. In the following pages APF sets out its proposals, starting with simple but effective applications for these types of lamps, and is preparing proposals for the LED segment. For a suitable choice of lamps dimmable systems, please consult the manuals of the manufacturers of lamps, in order to select the appropriate types. The consultation itself is also useful in reference to the alleged life of the lamps, which in most cases it is declared and reaches to hours of operation. This fact becomes significant compared to the expected life of other light sources such as LED. Energy saving lighting at night The switching on and off a lighting system at night are managed on the basis of the intensity of sunlight present at dusk and dawn. Consequently the change on road off throughout the year, following the curve of the times of sunset and sunrise. In contrast, the lighting needs, linked to attendance lit places ( such as traffic along a road ), remain constant throughout the year. From the graph in fig. 1 it is evident that the intensity of traffic daily ( week days and holidays ) falls before 50% in time of between 22 and 06. Significant energy savings can therefore be achieved through proper management of lighting at night in both public ( roads, intersections, parks, ) and private ( gardens, industrial areas, ) making sure that the power reduction of a plant with reduced lighting requirements typical of the times at which attendance is low. Several types of high pressure sodium lamps and metal halide lamp, you can control, so the savings can be made through bi power systems or power electronic hybrids that are switched to a reduced power at night, when the illumination that can be carried by operating at level of service. APF systems offer a command Intelligent and flexible, automatically adjusting power, without the presence of Line Rider, and adapting to all types of equipment ( excluding systems with centralized controllers ), switching systems using programmable or fixed. The range of production ENERGY SAVING includes: - Hybrid system with electromechanical ballast and electronic power switch coupled to programmable or fixed setting - Programmable Electronic Ballasts: programmable or fixed setting. fig.1 Traffic frequentation Operating Characteristics Each day the system through an internal timer measuring the total duration of power plant and provides the waiting time before switching. To obtain this time using an adaptive algorithm, that is able to maintain a constant, varying the total duration of the night, the switching time. How accurate can you get? Because the algorithm is based on the annual solar cycle, are not perfectly symmetrical in opposite seasons, there are differences on the switching times in different seasons. Sun reported the situation to Italy this difference is maintained ± 20 minutes. What happens to the return of summer or the sun? Automatically switching time moves one hour following the displacement of the clock. How to change the behaviour in different locations around the world? For the configuration of the algorithm for calculating the operating system is universal. Taking as reference the Italian switching latitudes there may be difference of up to ± 20 minutes using the system at the equator or near the polar circles. What if one day the system is switched to a different time than expected? In the event of a power plant run by Twilight early ( due to bad weather conditions ) the system will switch to a time earlier than the day before. In the following days, times when the power back to being normal, the system resumes normal operation. Other abnormal situations may be: Power plant for a few hours during the day ( due to extreme weather events ). The system switches to low power after the waiting time calculated ( if the power is long enough ), even though we are in broad daylight, days of operation remains unchanged. Plant shut down caused by interruption in the supply of energy. The system, the return of energy, partly in conditions of full power even if was previously under saving. In the days after the system resumes normal operation. These deviations from normal operation, however, provide a view of the effectiveness of safety and energy saving. Installation instructions The system works fine if the power plant is controlled by photoelectric switch or similar devices. To ensure correct timing of switching is desirable to avoid testing of the phases of longer than 6 hours. Otherwise the system realign its operation within 20 days after the first turn Pag. 1

3 W HPSV Lamps MH Lamps HYBRID Bi Level HID For High power Sodium vapour and Metal Halide vapour lamps ENERGY SAVING VALUES ENERGY SAVING VALUE 2350 h / anno 2930 h / anno calculated 4000 h / year at the cost of 0,17 / kwh Nominal Power W Total W CONSUMPTION kwh / year COST / year 40,8 55,76 76,84 113, , SAVING WITH PROGRAM: h reduction ( 2350 h / year ) CONSUMPTION kwh / year h x 60W 2350h x 39W 1650h x 82W 2350h x 53W 1650h x 113W 2350h x 74W 1650h x 167W 2350h x 107W 1650h x 275W 2350h x 164W 1650h x 433W 2350h x 262W / year 32,47 44,2 61,2 89,59 142,63 226,1 SAVING kwh / year / year 8,33 11,56 15,64 23,97 44,37 68,34 % 20,4 20,7 20,4 21,1 23,8 23,2 Kg. CO2 / year 24, ,5 130,5 201 SAVING PROGRAM Max. Maximum reduction ( 2930 h / anno ) Start Energy Saving h 22 NO STOP CONSUMPTION kwh / year h x 60W 2930h x 39W 1070h x 82W 2930h x 53W 1070h x 113W 2930h x 74W 1070h x 167W 2930h x 107W 1070h x 275W 2930h x 164W 1070h x 433W 2930h x 262W / year 29,92 41,31 57,46 83,64 131,75 209,27 SAVING kwh / year / year 10,88 14,45 19,38 29,92 55,25 85,17 % 26,7 25,9 25,2 26,3 29,5 28,9 Kg. CO2 / year 32 42, ,5 250,5 Pag. 2

4 50 400W BI LEVEL HYBRID RANGE Energy Saving Program Mains 230V ± 10% 50Hz % BI LEVEL PROGRAMMABLE WITH DIP SWITCH BI LEVEL NO PROGRAMMABLE Start Stop % Time h: 22/23/00/01 h: 05/06/07 /NO stop 40 Time Start h: 23 Stop h: 06 IP20 class I PRA W Pag. 5 7 Superimposed Ignitor Electromagnetic Ballast HPF Capacitor IP20 class I ( 0 / 1 fuse ) IPS W Pag. 6 7 Inside Superimposed Ignitor Timed Digital system 3,5 4,5kV / 200pF Electromagnetic Ballast HPF Capacitor IP20 class I ( 0 / 1 fuse ) PAK W Pag.8 Inside Superimposed Ignitor Timed Digital system 3,5 4,5kV / 200pF Inside Electromagnetic Ballast tw130 C Conform to the ErP EUP Directive HPF Capacitor ( 0 / 1 /2 fuse ) MB QUICK W Pag. 9 IP40 class II MB TB W Pag. 10 Inside Superimposed Ignitor Timed Digital system 3,5 4,5kV / 200pF Inside Electromagnetic Ballast tw130 C Conform to the ErP EUP Directive Inside HPF Capacitor cos > 0,90 MB GF QUICK W Pag. 11 ( 0 / 1 fuse ) IP66 class II MP FAST W Pag. 12 BF PRA W Pag. 13 Inside Superimposed Ignitor Timed Digital system 3,5 4,5kV / 200pF Inside Electromagnetic Ballast tw130 C Conform to the ErP EUP Directive Inside HPF Capacitor cos > 0,90 Pag. 3

5 W HPSV MH Lamps PR A 400 PR A Intelligent Power Switch ENERGY SAVING SYSTEM 220 / 240V 50/60Hz ta C I Sistemi Intelligent Power Switch sono abbinabili ad Alimentatori elettromagnetici ( Hybrid system ) e sono inseriti nei sistemi IP40 ON MAY 2011 THE SYSTEM HAD A RECOGNITION AT ECOHITECH AWARD IT IS THE MOST IMPORTANT RECOGNITION AWARD ANNUALLY TO COMPANIES THAT HAVE ACHIEVED SIGNIFICANT RESULTS IN TERMS OF ENVIRONMENTALLY FRIENDLY EXPLOITING INNOVATION TECHNOLOGIES. AUTOMATIC PROGRAMMABLE POWER REDUCTION System: PRA 400 Cod PRA Esclusione di ritorno a piena potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Remote control Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Remote control Peso / weigth: 0,18 Kg h ( / 20 min ) h start stop anno Factory setting : start 22h / NO stop AUTOMATIC POWER REDUCTION System: PRA Cod PRA1 Remote control Peso / weigth: 0,18 Kg Energy Saving start: 23 h ( 00 legal hour ) / 20 min Energy Saving stop after max. 7 hours Standard program 2350 h / year Energy Saving Energy Saving start: 22 h ( 23 legal hour ) / 20 min Energy Saving stop after max. 8 hours ( on requeste ) 2750 h / year Energy Saving Pag. 4

6 70 400W HPSV MH Lamps IPS Power Reduction Ignition Built in High performance electronic kit For HID lamps 230V 50Hz tc C IP 20 class I REFERENCE STANDARD Safety: EN / EN Performance: EN R.F.I. Emissions: EN Immunity: General Characteristics Hybrid System ( Electromechanical ballast ) Commutatore automatico series PRA Automatic Power Switch Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf Safety Timed Digital IGNITOR Connettore sezionabile a vite 0,5 2,5mm² Separating screw terminal Fusibile sostituibile a richiesta Ø 5 x 20mm 10A 250V T Replaceable fuse on request Production range Programmable Kit Lamps W Type / cod. Type / cod. Kg. 70 / 400 IPS IPS IPS IPS 0,18 Vedi tabella: pag :4 See table : Esclusione di ritorno a piena Potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Remote Control Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Lamps W Reference APF Electromagnetic ballast Reference HPF capacitor > 0,90 250Vl µf ( ±10% ) A ( in ) 70 (0,98A) SAPIM VST 70/ , (1,20A) SAPIM VT 100/ ,5 0, (1,80A) SAPIM VST 150/100.3 TP 18 0, (3,00A) SAPIM 250/150.3 TP 32 1, (4,40A) SAPIM 400/250.3 TP 45 2,10 Pag. 5

7 70 400W HPSV / MH Lamps 70 / 50W 100 / 70W 150 / 100W 250 / 150W 400 / 250W HIBRID Bi Level HID Energy Saving SERIE DA INCORPORARE BUILT IN TYPE Hybrid System 230V 50Hz IP 20 Class I REFERENCE STANDARD EN EN Safety EN EN Performance Harmonic Limits R.F.I. Emissions Immunity Flicker Lampade Caratteristiche generali Abbinabile a commutatore: Coupling with Power Switch : Automatici Programmabili PRA 400 / IPS 400 Automatic Programmable Automatici fissi PRA / IPS Automatic fix Alimentatore a basse perdite ( tw 130 C ) Low losses Ballast, conform to the conforme alla Direttiva ErP EUP to ErP EUP Directive, Abbinabile ad accenditori a sovrapposizione F400 / E400 / PWE400 Coupling with Superimposed IGNITOR Connettore a vite 0,75 to 2,5mm² Screw terminals Control Gear Range Control Gear Characteristics HPF Cap. Nominale ridotto Type Cod: Δt Losses λ appr. cos> 0,90 W A W K W* pf 10% A in 70 0,98 50 SAPIM VST 70/ V29 75/ ,36 0, , ,20 70 SAPIM VT 100/ V00 70/ ,41 0,39 12,5 0, , SAPIM VST 150/100.3 TP V60 75/60 17,5 13 0,40 0, , , SAPIM 250/150.3 TP / ,40 0, , , SAPIM 400/250.3 TP / ,45 0, ,10 Schema di collegamento e dimensioni Drawing and dimensions Schema con: PRA 400 / PRA Drawing. with: Schema con: IPS 400 IPS Drawing. With: W L L1 Kg W L L1 Kg , , , , ,07 Pag. 6

8 W HPSV MH Lamps 230V 50Hz 50 / 35W PAK Power Reduction Ignition Ballast 70 / 50W Built in Hybrid High performance Control Gear 100 / 70W For HID lamps 150 / 100W IP 20 class I REFERENCE STANDARD Safety: EN / EN / EN Performance: EN / EN Harmonic Limits. EN R.F.I. Emissions: EN Immunity: General Characteristics Hybrid System ( Electromechanical ballast ) Alimentatore a basse perdite conforme alla Direttiva ErP EUP tw 130 C Low losses Ballast, conform to ErP EUP Directive Connettore sezionabile a vite 0,5 2,5mm² Separating screw terminal Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse Commutatore automatico series PRA Automatic Power Switch Programmable Kit Lamps W Vedi tabella: pag :4 See table : Esclusione di ritorno a piena Potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Remote Control Remote Control Production range for Lamps HPSV with Internal Ignitor 50 / 35 PAKAP 50 / 35.3 / EF PAE PAKBT 50 / 35.3 / EF PKE 1,25 70 / 50 PAKAP 70 / 50.3 / EF PAE PAKBT 70 / 50.3 / EF PKE 1,35 Production range for Lamps required Ignitor Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf ( 1,8 2, 3 kv for 50W Lamps ) Safety Timed Digital IGNITOR Lamps W Type / cod. Type / cod. Kg. 50 / 35 PAKAP 50 / 35.3 / F PAP PAKBT 50 / 35.3 / F PAK 1,25 70 / 50 PAKAP 70 / 50.3 / F PAP PAKBT 70 / 50.3 / F PAK 1, / 70 PAKAP 100 / 70.3 / F PAP PAKBT 100 / 70.3 / F PAK 1, / 100 PAKAP 150 / / F PAP PAKBT 150 / / F PAK 2,40 Kg. PENDING APPROVAL Lamps W Nominal lamp Reduced lamp Saving Δt K λ L L1 HPF capacitor > 0,90 250Vl W W ( t ) W W ( t ) W µf ( ±10% ) A ( in ) 50 (0,53A) /45 0,33 0, ,30 70 (0,98A) /60 0,36 0, , (1,20A) /55 0,41 0, ,5 0, (1,80A) /60 0,40 0, ,78 Pag. 7

9 W HPSV MH Lamps 230V 50Hz 50 / 35W QUICK MINI BASYC Energy Saving ta C 70 / 50W Independent Hybrid High performance Control 100 / 70W Gear For HID lamps 150 / 100W IP 40 REFERENCE STANDARD Safety: EN / EN / EN / EN / EN / EN Performance: EN / EN Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN General Characteristics Hybrid System ( Electromechanical ballast ) Alimentatore a basse perdite conforme alla Direttiva ErP EUP tw 130 C Low losses Ballast, conform to ErP EUP Directive Condensatore di rifasamento HPF cosφ > 0,90 High Power Factor Capacitor Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf ( 1,8 2, 3 kv for 50W Lamps Safety Timed Digital IGNITOR Connettore sezionabile a vite 1 4,0mm² ( cable 9 11mm ) Separating screw terminal Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse Commutatore automatico series PRA Automatic Power Switch Programmable Kit Vedi tabella: pag :4 See table : Esclusione di ritorno a piena Potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Remote Control Remote Control Lamps W 50 / 35 In 0,30A 70 / 50 In 0,41A 100 / 70 In 0,53A 150 / 100 In 0,78A Programmable connector* Type / cod. MB APC 50.3 Q / F APC MB APC 70.3 Q / F APC MB APC Q / F APC MB APC Q / F APC PENDING APPROVAL Production range Type / cod. MB PRA 50.3 Q / F A MB PRA 70.3 Q / F A MB PRA Q / F A MB PRA Q / F A Kg. 2,00 2,10 2,15 2,75 * Patented Programmable connector: Il connettore consente la sostituzione del sistema mantenendo la programmazione di prima installazione o riprogrammazione The connector allow the replacement of the control gear ( hybrid or electronic ) while maintaining the original programming or changing Pag.8

10 W HPSV MH Lamps 230V 50Hz 50 / 35W TB MINI BASYC Energy Saving ta C 70 / 50W Independent Hybrid High performance Control 100 / 70W Gear For HID lamps 150 / 100W IP 40 REFERENCE STANDARD Safety: EN / EN / EN / EN / EN Performance: EN / EN Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN General Characteristics Hybrid System ( Electromechanical ballast ) Alimentatore a basse perdite conforme alla Direttiva ErP EUP tw 130 C Low losses Ballast, conform to ErP EUP Directive Condensatore di rifasamento HPF cosφ > 0,90 High Power Factor Capacitor Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf ( 1,8 2, 3 kv for 50W Lamps Safety Timed Digital IGNITOR Connettore a vite 1 2,5mm² ( cable 7 9mm ) Screw terminal Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse Commutatore automatico series PRA Automatic Power Switch Programmable Kit Vedi tabella: pag :4 See table : Esclusione di ritorno a piena Potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Remote Control Remote Control Lamps W 50 / 35 In 0,30A 70 / 50 In 0,41A 100 / 70 In 0,53A 150 / 100 In 0,78A Programmable connector* Type / cod. MB AP 50.3 TB / F AP MB AP 70.3 TB / F AP MB AP TB / F AP MB AP TB / F AP Production range Type / cod. MB PRA 50.3 TB / F A MB PRA 70.3 TB / F A MB PRA TB / F A MB PRA TB / F A Kg. 2,00 2,10 2,15 2,75 Pag. 9

11 W HPSV MH Lamps 230V 50Hz 250 / 150W MINI BASYC GF Energy Saving ta C 400 / 250W Independent Hybrid High performance Control Gear For HID lamps IP 40 REFERENCE STANDARD Safety: EN / EN / EN / EN / EN Performance: EN / EN Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN Dim. L L1 250W W General Characteristics Hybrid System ( Electromechanical ballast ) Alimentatore a basse perdite conforme alla Direttiva ErP EUP tw 130 C Low losses Ballast, conform to ErP EUP Directive Condensatore di rifasamento HPF cosφ > 0,90 High Power Factor Capacitor Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf ( 1,8 2, 3 kv for 50W Lamps Safety Timed Digital IGNITOR Connettore sezionabile a vite 1 4,0mm² ( cable 9 11mm ) Separating screw terminal Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse Commutatore automatico series PRA Automatic Power Switch Programmable Kit Vedi tabella: pag :4 See table : Esclusione di ritorno a piena Potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Remote Control Remote Control Lamps W 250 / 150 In 1,35A 400 / 250 In 2,10A Programmable connector* Type / cod. MB GF APC Q / F APC MB GF APC Q / F APC Production range Type / cod. MB GF A Q / F GA MB GF A Q / F GA Kg. 3,80 5,10 * Patented Programmable connector: Il connettore consente la sostituzione del sistema mantenendo la programmazione di prima installazione o riprogrammazione The connector allow the replacement of the control gear ( hybrid or electronic ) while maintaining the original programming or changing Pag. 10

12 W HPSV MH Lamps 230V 50Hz 50 / 35W MINI PLUS FAST Energy Saving ta C 70 / 50W Independent Hybrid High performance Control 100 / 70W Gear For HID lamps 150 / 100W IP 66 REFERENCE STANDARD Safety: EN / EN / EN / EN / EN Performance: EN / EN Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN General Characteristics Hybrid System ( Electromechanical ballast ) Alimentatore a basse perdite conforme alla Direttiva ErP EUP tw 130 C Low losses Ballast, conform to ErP EUP Directive Condensatore di rifasamento HPF cosφ > 0,90 High Power Factor Capacitor Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf ( 1,8 2, 3 kv for 50W Lamps Safety Timed Digital IGNITOR Connettore ad innesto rapido 1 2,5mm² Patented fast connection Screwless terminal Pressacavi per cavi: Ø mm type H07 RN F ( or similar ) Cable gland for cable: Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse Commutatore automatico series PRA Automatic Power Switch Programmable Kit Vedi tabella: pag :4 See table : Esclusione di ritorno a piena Potenza Energy Saving Stop per impostazione a potenza fissa ( max/min ) Exclusion of return to full power Energy Saving Stop to set at fix power ( max/min ) Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Remote Control Remote Control Lamps W 50 / 35 In 0,30A 70 / 50 In 0,41A 100 / 70 In 0,53A 150 / 100 In 0,78A Programmable connector* Type / cod. MPF AP 50.3 / F AP MPF AP 70.3 / F AP MPF AP / F AP MPF AP / F AP Production range Type / cod. MPF PRA 50.3 / F A MPF PRA 70.3 / F A MPF PRA / F A MPF PRA / F A Kg. 1,60 1,65 1,75 2,70 Pag. 11

13 W HPSV MH Lamps 230V 50Hz 250 / 150W BF PRA Energy Saving ta C 400 / 250W Independent Hybrid High performance Control Gear For HID lamps IP 66 REFERENCE STANDARD Safety: EN / EN / EN / EN / EN Performance: EN / EN Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN General Characteristics Hybrid System ( Electromechanical ballast ) Alimentatore a basse perdite conforme alla Direttiva ErP EUP tw 130 C Low losses Ballast, conform to ErP EUP Directive Condensatore di rifasamento HPF cosφ > 0,90 High Power Factor Capacitor Accenditore digitale temporizzato di sicurezza 3,5 4,5 kv 200 pf ( 1,8 2, 3 kv for 50W Lamps Safety Timed Digital IGNITOR Connettore ad innesto rapido 1 2,5mm² Patented fast connection Screwless terminal Pressacavi per cavi: Ø mm type H07 RN F ( or similar ) Cable gland for cable: Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse Commutatore automatico series PRA Automatic Power Switch Standard Program Start 23 h Stop after max. 7 h Energy Saving ( 2350 h/year ) Remote Control Lamps W 250 / 150 In 1,35A 400 / 250 In 2,10A Programmable connector* Type / cod. BF PRA PRA BF PRA PRA Production range Type / cod. 4,60 5,90 Kg. 250 / 150 In 1,35A 400 / 250 In 2,10A Pag. 12

14 MULTI LEVEL ELECTRONIC BALLAST RANGE Energy Saving Program W HPSV LAMPS / W Cosmopolis Lamps BI LEVEL PROGRAMMABLE WITH DIP SWITCH TRI LEVEL PROGRAMMABLE WITH DIP SWITCH BI LEVEL NO PROGRAMMABLE BI LEVEL PROGRAMMABLE RANGE ( La potenza minima è in funzione del tipo di ballast The minimun wattage working depending of ballast type ) TRI LEVEL PROGRAMMABLE RANGE ( La potenza minima è in funzione del tipo di ballast The minimun wattage working depending of ballast type ) % Start Stop % 100 Start Start MIN Stop MIN Stop Time h: 22/23/00/01 h: 05/06/07 /NO stop 40 Time h: 22/23 h:00/01 h: 05/06 07/NO stop Energy Saving Stop per impostazione a potenza fissa ( max/min ) Energy Saving Stop per impostazione a potenza fissa ( max/min ) Energy Saving Stop to set at fix power ( max/min ) Energy Saving Stop to set at fix power ( max/min ) Remote Control Remote Control Programmable IP20 class I PR EL 400 Programmable IP20 class I Built in PR EL 1 10V PR EL 400 PR EL 1 10V PRE 58000PR10 SWITCHED Electronic Ballast IP40 class II ( pag 16 HPSV / 18 COSMOPOLIS ) 1 10V Electronic Ballast IP40 class II ( pag 16 HPSV / 18 COSMOPOLIS ) Ballast con linea pilota Funzionamento anche senza PREL400 Ballast con linea pilota Funzionamento anche senza PREL1 10V Ballast with pilote line Ballast with pilote line Working also without PREL 400 Working also without PREL 1 10 Programmable IP40 class II ( 0/1/2 Fuse ) MB GFE DIM ( pag 16 HPSV / 18 COSMOPOLIS ) Programmable IP40 class II ( 0/1/2 Fuse ) MB GFE 1 10V ( pag 16 HPSV / 18 COSMOPOLIS ) Programmable Connector Programmable Connector % BI LEVEL RANGE ( pag 17 HPSV / 19 COSMOPOLIS ) Program CG Start 24h Stop after max. 6 h EB EXT DIM CG 24h 6h Time Start h: 23 Stop h: 06 Program CG Start 24h Stop after max. 8 h EB EXT DIM CG 22h 6h Pag. 13

15 ENERGY SAVING VALUE Electronic Bi Level HID 2100 h / anno 2750 h / anno Data at full power High performance control gear for W HPSV / MH Lamps calculated 4000 h / year at the cost of 0,17 / kwh RANGE OF LAMPS Potenza nominale / totale W 70 ( 78 W ) 100 ( 108 W ) 150 ( 163 W ) CONSUMPTION kwh / year COST / year 53,04 73,44 110,84 SAVING WITH PROGRAM: 6 h reduction ( 2100 h / year ) CG CONSUMPTION kwh / year ( 1900h x 78W 2100h x 43 ) ( 1900h x 108W 2100h x 58 ) ( 1900h x 163W 2100h x 88 ) / anno 40,46 55,59 84,15 SAVING kwh / year / year 12,58 17,85 26,69 % Kg. CO2 / year 37 52,5 78,5 SAVING WITH PROGRAM: 8 h reduction ( 2750 h / year ) CG CONSUMPTION kwh / year ( 1250h x 78W 2750h x 43 ) ( 1250h x 108W 2750h x 58 ) ( 1250h x 163W 2750h x 88 ) / anno 36,72 50,15 75,82 SAVING kwh / year / year 16,32 23,29 35,02 % Kg. CO2 / year 48 68,5 103 Data at full power High performance control gear for W Cosmo Polis Lamps calculated 4000 h / year at the cost of 0,17 / kwh RANGE LAMPADE Potenza nominale / totale W 60 ( 67 W ) 90 ( 98 W ) 140 ( 153 W ) CONSUMPTION kwh / year COST / year 45,56 66,64 104,04 SAVING WITH PROGRAM: 6 h reduction ( 2100 h / year ) CG CONSUMPTION kwh / year ( 1900h x 67W 2100h x 52 ) ( 1900h x 98W 2100h x 62 ) ( 1900h x 153W 2100h x 97 ) / anno 40,12 53,72 83,98 SAVING kwh / year / year 5,44 12,92 20,06 % Kg. CO2 / year SAVING WITH PROGRAM: 8 h reduction ( 2750 h / year ) CG CONSUMPTION kwh / year ( 1250h x 67W 2750h x 52 ) ( 1250h x 98W 2750h x 62 ) ( 1250h x 153W 2750h x 97 ) / anno 38,59 49,81 77,86 SAVING kwh / year / year 6,97 16,83 26,18 % Kg. CO2 / year 20,50 49,5 77 Pag. 14

16 W HPSV Lamps TOTAL 70 / 50W 100 / 70W 150 / 100W REFERENCE STANDARD Safety: EN / EN / EN / EN ELECTRONIC Multi level Energy Saving Independent Electronic High performance Control Gear For HID lamps ELECTRONIC 220/240V 50/60Hz ta C IP 40 Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN General Characteristics Mains V ( V ) 50 / 60 Hz Cos >0,98 Disinserzione automatica con lampada difettosa Automatic cut out with damage lamp Disattivazione in caso di sovratemperatura Switch off in case of over temperature Massima distanza alimentatore / lampada 2 m Maximum lamp / ballast distance Connettore ad innesto rapidi per cavi rigidi o flessibili 0,75 to 2,5mm² Screw less terminals EB Series NO PROGRAMMABLE Start 24h Stop after max. 6 h SWITCHED PROGRAMMABLE DIMMABLE 1 10V PROGRAMMABLE Abbinabile / Coupling PR EL 400 Abbinabile / Coupling PR EL 1 10V For programmable BI LEVEL System For programmable TRI LEVEL System Lamps W Type / cod. Type / cod. Type / cod. Kg. 70 / 35 EB EXT DIM 70 CG 24h 6h EB EXT DIM 70 CG SW EB EXT DIM 70 CG 10 0,4 In 0,35A / 50 In 0,50A 150 / 75 In 0,72A MB GF series EB EXT DIM 100 CG 24h 6h EB EXT DIM 150 CG 24h 6h EB EXT DIM 100 CG SW EB EXT DIM 100 CG 10 0,4 EB EXT DIM 150 CG SW EB EXT DIM 150 CG 10 0,5 Queste configurazioni rendono autonomo il control gear da ulteriori collegamenti With this configuration is not necessary other cables for connection 0 / 1 / 2 : Fusibile sostituibile Ø 5 x 20mm 10A 250V T 0 / 1 / 2 Replaceable fuse BI LEVEL ELECTRONIC CONTROL GEAR TRI LEVEL ELECTRONIC CONTROL GEAR DIMMABLE 1 10V ELECTRONIC BALLAST PROGRAMMABLE CONNECTOR PROGRAMMABLE CONNECTOR Lamps W Type / cod. Type / cod. Kg. 70 / 35 MB GFE APC 70 Q / F MB GFE APC 70 Q / F 10 In 0,35A 7070MBAPC 7070MBA10 0,8 100 / 50 MB GFE APC 100 Q / F MB GFE APC 100 Q / F 10 In 0,50A 7010MBAPC 7010MBA10 0,8 150 / 75 MB GFE APC 150 Q / F MB GFE APC 150 Q / F 10 In 0,72A 7015MBAPC 7015MBA10 0,9 Pag. 15

17 W COSMOPOLIS LAMPS ELECTRONIC Multi level Energy Saving Independent Electronic High performance Control Gear For HID lamps TOTAL ELECTRONIC 220/240V 50/60Hz ta C IP 40 REFERENCE STANDARD Safety: EN / EN / EN / EN Harmonic Limits: EN Immunity: R.F.I. Emissions: EN Flicker: EN General Characteristics Mains V ( V ) 50 / 60 Hz Cos >0,98 Disinserzione automatica con lampada difettosa Automatic cut out with damage lamp Disattivazione in caso di sovratemperatura Switch off in case of over temperature Massima distanza alimentatore / lampada 2 m Maximum lamp / ballast distance Connettore ad innesto rapidi per cavi rigidi o flessibili 0,75 to 2,5mm² Screw less terminals EB Series NO PROGRAMMABLE Start 24h Stop after max. 6 h SWITCHED PROGRAMMABLE DIMMABLE 1 10V PROGRAMMABLE Abbinabile / Coupling PR EL 400 Abbinabile / Coupling PR EL 1 10V For programmable BI LEVEL System For programmable TRI LEVEL System Lamps W Type / cod. Type / cod. Type / cod. Kg. 60/ 45 EB EXT DIM 60 CG 24h 6h EB EXT DIM 60 CG SW EB EXT DIM 60 CG 10 0,4 In 0,30A / 55 In 0,45A 140 / 88 In 0,68A MB GF series EB EXT DIM 90 CG 24h 6h EB EXT DIM 140 CG 24h 6h EB EXT DIM 90 CG SW EB EXT DIM 90 CG 10 0,4 EB EXT DIM 140 CG SW EB EXT DIM 140 CG 10 0,5 Queste configurazioni rendono autonomo il control gear da ulteriori collegamenti With this configuration is not necessary other cables for connection 0 / 1 / 2 : Fusibile sostituibile Ø 5 x 20mm 10A 250V T Replaceable fuse BI LEVEL ELECTRONIC CONTROL GEAR TRI LEVEL ELECTRONIC CONTROL GEAR DIMMABLE 1 10V ELECTRONIC BALLAST PROGRAMMABLE CONNECTOR PROGRAMMABLE CONNECTOR Lamps W Type / cod. Type / cod. Kg. 60/ 45 MB GFE APC 60 Q / F MB GFE APC 60 Q / F 10 In 0,30A 7060MBAPC 7060MBA10 0,8 90 / 55 In 0,45A 140 / 88 In 0,68A MB GFE APC 90 Q / F 7090MBAPC MB GFE APC 140 Q / F 7014MBAPC Pag. 16 MB GFE APC 90 Q / F MBA10 MB GFE APC 140 Q / F MBA10 0,8 0,9

18 Automatic and Programmable Power Reduction Energy Saving Program DIP SWITCH SETTING FOR PROGRAMMABLE SYSTEMS The n 1 dip switch, position 0, empowers the energy saving functions while in position ON the fixed power ones. In order to configure the Energy Saving parameters, dip switches n are to be used. In order to configure the fixed power level, the dip switch n 2 is to be used. Energy Saving program h Start NO h Stop Dip switch on Locked (w) program Max. Min. The setting ( factory setting ) corresponds to the Energy Saving function with reduction at 10p.m. and switch off during day time. Besides the programmable characteristics, the Energy Saving Systems are able to execute : 1 ) Change over control test in factory 2 ) Manual or automatic remote control 1 ) Change over control test in factory The A cycle allows to test unlimited times at the lighting fittings manufacturer. Every test has to take no more than 6 hours. After the first night working, this function is cancelled. MAX (W) Accensione Start Energy Saving ( h) Stop Energy Saving ( h) no/day light MIN (W) Time ( h ) in Energy Saving Time sec Cycle A Pag. 17

19 Remote Control Operation Energy Saving Program 2 ) Manual or automatic remote control Every energy saving system, both programmable or fixed, can vary some parameters by means of a centralized remote control, by sending a defined number of sequences and impulses on the power line. Manual control Without any further control, a switch on and off sequence is to be given during the day before the night concerned by the change. The sequence time has to be : ON ( 230V ± 10% ) t = 5 10sec OFF t = 5 8sec SEQUENCE: 3 = System checking test 4 = Setting for 1 day in maximum power 6 = Setting for 7 day in maximum power 8 = Setting for 1 day in minimum power 10 = Setting for 7 day in minimum power CANCELLATION OF REMOTE PROGRAMMING ON = N 12 t = 5 10sec N 1 t = > 30 sec OFF t > 4 sec. We advise not to use the manual control too often in order to avoid useless switch on and off of lamps, caused by the impulses sequence of power line. Programmable automatic control Sequences are given automatically thanks to a control panel. By this means it is possible to exclude the starting working program. Besides easiness and flexibility, the voltage value is less than 150V avoiding useless switch on and off of the lamp. There are two kinds of remote control panel. 1 With selector for the above mentioned functions ( automatic sequence) 2 With yearly programmatore allowing a daily, weekly and monthly selection and fixing the working in maximum or minimum power. The aim is to fit the system with the various seasons and their different needs. In some part of the year, a working with minimum power has to be preferred while in some others, a working with maximum power. Advantages are safety, saving and pollution prevention. By means of the control panel, it is possible to program in place or thanks to a transferred program with USB support. Apart from the program, a push button will allow the automatic test of the whole system reporting the correct working. Technical and dimensional characteristic will follow in the shortest time. Pag.18

20 APF S.r.l. Via Edison, 3 Burago di Molgora ( MI ) ITALY Tel r.a Fax r.a info@apfitalia.com HID ENERGY SAVING PROGRAM ( IT )

AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER

AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER AMDx4 INTERFACE CONTROL PANEL FOR AUTOMATIC SOFTENERS AM/D METER INSTRUCTIONS MANUAL INSTRUCTIONS FOR INSTALLATION OPERATION & MAINTENANCE WARNING! The equipment must be used only for the utilization for

More information

High Pressure Mercury

High Pressure Mercury High Pressure Mercury E27 B Product Description Mixed Light lamps Product Features High-pressure mercury tube in series with a tungsten filament Runs on mains voltage without additional gear Combines a

More information

Rated Lumen [lm] Nominal. Volts [V] [lm]

Rated Lumen [lm] Nominal. Volts [V] [lm] GE Lighting rcstream Metal Halide lamps Tubular Clear 25W and W Elliptical Diffuse 25W DT SHEET Product information High brightness, high quality white light with good colour rendition and energy efficiency

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5 T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim

More information

DuroSite TM High Bay Lighting

DuroSite TM High Bay Lighting DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5 F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via

More information

n N e E 0 m A R sr S l 10.2015 230/01

n N e E 0 m A R sr S l 10.2015 230/01 N 0 E A R n e msrls 10.15 230/01 Cablaggi LED LED wiring NEM s.r.l. ha nella propria gamma di prodotti due diversi cablaggi per LED. In its product range, NEM s.r.l. offers two different LED wirings. 051

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

ConstantColor CMH MR16

ConstantColor CMH MR16 GE Lighting ConstantColor CMH MR16 Reflector Ceramic Metal Halide Lamps W and 35W DATA SHEET Product information ConstantColor CMH lamps combine HPS technology (providing stability, efficiency & uniformity)

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Heating Controller. Building Technologies HVAC Products

Heating Controller. Building Technologies HVAC Products 2 474 Heating Controller RVP300 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones with or

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

POMPE ROTOMEC. ELETTROPOMPE SOMMERGIBILI Submersible pumps. IMPIEGO - Application. DESCRIZIONE - Description. DATI ELETTRICI - Electric data

POMPE ROTOMEC. ELETTROPOMPE SOMMERGIBILI Submersible pumps. IMPIEGO - Application. DESCRIZIONE - Description. DATI ELETTRICI - Electric data POMPE ROTOMEC ELETTROPOMPE SOMMERGIBILI Submersible pumps UNI EN ISO 9-8 serie 5 TR.6 H (m) GIRANTE VORTEX - Vortex impeller 96 Giri / - R.P.M. Curve secondo ISO 996 Liv: (P).... 5 5 6 7 5 5 l/sec Q m³/h

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Alimentatori LED LED drivers

Alimentatori LED LED drivers Alimentatori LED LED drivers ALimentatori LED LED drivers Alimentatori disponibili in diverse potenze e dimensioni con caratteristiche tecniche specifiche per settore di utilizzo Alimentatori per applicazioni

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

LED Power. Power Supplies for constant current HI-POWER LEDs 350/700mA Alimentatori per LED in corrente costante HI-POWER 350/700mA 82206/700

LED Power. Power Supplies for constant current HI-POWER LEDs 350/700mA Alimentatori per LED in corrente costante HI-POWER 350/700mA 82206/700 LED Power The power supplies and accessories showed in this section are designed to achieve the best lighting and long lasting performances for LED fixtures. A particular attention has been dedicated to

More information

Applications. Architectural

Applications. Architectural GE Lighting Arcstream Single Ended Metal Halide lamps 7W and 15W DATA SHEET Product information Arcstream Single Ended lamp consists of a compact high pressure metal halide discharge operating in a quartz

More information

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5 E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or

More information

MINI CONTATTORI / MINI CONTACTORS

MINI CONTATTORI / MINI CONTACTORS Informazioni generali / General information pag. 54 Caratteristiche tecniche / Technical datas pag. 57 Codici di ordinazione / Ordering product codes pag. 60 53 CONTTTORI TRIPOLRI CIRCUITO DI COMNDO C..

More information

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag. 1-48 Product selection. Caratteristiche tecniche pag. 1-51 Tecnical data

INDICE MINI-CONTATTORI / CONTENTS MINI-CONTACTORS. Criteri di scelta pag. 1-48 Product selection. Caratteristiche tecniche pag. 1-51 Tecnical data Indice Contents CONTROLLO MOTORE MOTOR CONTROL INDICE MINICONTTTORI / CONTENTS MINICONTCTORS Criteri di scelta pag. 8 Product selection Caratteristiche tecniche pag. Tecnical data 77 Criteri di scelta

More information

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5 EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

EC DECLARATION OF CONFORMITY FOR MACHINES

EC DECLARATION OF CONFORMITY FOR MACHINES EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) Manufacturer: Address: Declares that: FAAC S.p.A. Via Benini, 1-40069 Zola Predosa BOLOGNA - ITALY 770 mod. operator is built to be integrated

More information

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

REVO-LB. REVO LB (Low Bay Industrial Luminaires) REVO-LB REVO LB (Low Bay Industrial Luminaires) LOW BAY INDUSTRIAL LUMINAIRES The REVO-LB luminaires have been developed as a new series to be used on low ceilings (Low Bay) adding to our successful energy-saving

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag.

CONTENTS. 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. 2. DESCRIPTION pag.12. 3. TECHNICAL SPECIFICATIONS pag.13. 4. INSTALLATION pag. CONTENTS 1. CE DECLARATION OF CONFORMITY FOR MACHINES pag.11. DESCRIPTION pag.1 3. TECHNICAL SPECIFICATIONS pag.13 4. INSTALLATION pag.13 5. TESTING THE AUTOMATED SYSTEM pag.19 6. MANUAL OPERATION pag.19

More information

Dimensions in mm. www.lampsandgear.philips.com. S10 Starter in white canister. S2 Starter in white canister FLUORESCENT LAMPS & CONTROL GEAR 3.

Dimensions in mm. www.lampsandgear.philips.com. S10 Starter in white canister. S2 Starter in white canister FLUORESCENT LAMPS & CONTROL GEAR 3. Fluorescent TL starter Starters for Fluorescent Lamps S10 Starter in white canister B Product Description Premium-quality glow switches range for igniting conventional electromagnetic fluorescent lamps

More information

THERMAL ENERGY METER MC 108/ET

THERMAL ENERGY METER MC 108/ET USCITE CONTATORE DI CALORE CONVERTITORE SENSORE ELETTROMAGN. EUROMAG CONTATORE DI ENERGIA TERMICA PORTATA: SENSORE ELETTROMAGN. uscite: TEMPERATURE: Pt 100 4-20 ma potenza termica 4-20 ma temperatura ta

More information

GE ConstantColor CMH Precise MR16 20 & 35W

GE ConstantColor CMH Precise MR16 20 & 35W GE Lighting GE ConstantColor CMH Precise MR16 2 & 35W DATA SHEE T TECHNOLOGY ConstantColor CMH lamps combine HPS technology (providing stability, efficiency & uniformity) and Metal Halide Technology (providing

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Light First Social innovation through lighting

Light First Social innovation through lighting Wow Clever Light 1 2 Light First Social innovation through lighting Socially engaged iguzzini is an international community at the service of architecture and the development of the culture of lighting,

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

BURNER WATER CONTROL UNIT

BURNER WATER CONTROL UNIT BURNER WATER CONTROL UNIT Energy Saving Technology MODELS AQUAMATIC 1 A / B AQUAMATIC 2 A / B LB 1003 04.12.98 TABLE OF CONTENTS: TECHNICAL SPECIFICATIONS FOR AQUAMATIC CONTROL UNITS.... pag. 4 WATER

More information

ALIMENTATORI LED DRIVER LED

ALIMENTATORI LED DRIVER LED ALIMENTATORI LED DRIVER LED BDF6 Super slim LED Driver in corrente costante 350mA classe II, morsetti a vite Super-slim 350mA constant current LED driver, class II, screw terminal I POWER Input Input H

More information

Via dell' Industria, 25-31020 S. Vendemiano (TV) Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it e-mail Acquisti@elettrolab.

Via dell' Industria, 25-31020 S. Vendemiano (TV) Tel. 0438 470047 Fax. 0438 470100 - www.elettrolab.it e-mail Acquisti@elettrolab. EDB300 Electronic Digital Ballast 300W DSP controlled Features: Electronic digital ballast suitable for 300W HID lamps Built-in PFC (pf>0.98 90-260 Vac full range). EMI filter inside. Compact shape, low

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Frequency selective monitoring and logging of environmental electromagnetic fields

Frequency selective monitoring and logging of environmental electromagnetic fields FREQUENCY SELECTIVE EMF AREA MONITOR AMS-8060 Frequency selective monitoring and logging of environmental electromagnetic fields Up to 20 fully programmable frequency bands Real built-in spectrum analyser

More information

Urban lighting luminaire ECOLO. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

Urban lighting luminaire ECOLO. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato) Urban lighting luminaire ECOLO Registered models - Design Massimo Sacconi NERO e GRIGIO per marchi piccoli Ecolo is a versatile and multifunctional solution designed to enhance the most different urban

More information

C Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz

C Series. 16(5)A at 250V A.C 50Hz. 3A at 30V D.C. L/R=5ms 10 milioni di operazioni a 1 Hz / million operations at 1Hz 1250Vrms at 50Hz C Series Il microinterruttore della serie C é un trasduttore elettromeccanico capace di commutare carichi fino a 20A, è dotato di lunga vita, bassa corsa differenziale, alta ripetibilità e buona resistenza

More information

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions DAI DIM/COVERTER COTRO (DC V) 1 10V (0-10 V) analog DAI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions Dim-and Switch Functions: The DAI Dim/Converter Control DC V is suitable

More information

Stove Guard Kit User Manual

Stove Guard Kit User Manual Stove Guard Kit User Manual Innohome improves the Safety of your Home. inno home www.innohome.com Stove Guard Kit User Manual Stove Guard Kit User Manual Congratulations! You now own one of the most intelligent

More information

Digital gear for fluorescent lamps

Digital gear for fluorescent lamps Catalogue 2000/2001 Digital gear for fluorescent lamps Comprehensive range of literature available: Magnetic control gear for fluorescent lamps Control gear for high pressure discharge lamps Transformers

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Transmitter Actuator 230V wave UP 560. Operation

Transmitter Actuator 230V wave UP 560. Operation Transmitter ctuator 230V wave UP 560 5WG3 560-201 Product- and pplication Description Diagram The transmitter actuator 230V wave UP 560 (Diagram ) is a flush-mounted device with radio communication for

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch

More information

DUAL FUEL BURNERS GAS/HEAVY OIL

DUAL FUEL BURNERS GAS/HEAVY OIL M A D E I N I TA LY SERIE KN 750/M_1000/M EL DUAL FUEL BURNERS GAS/HEAVY OIL BRUCIATORI MISTI GAS/OLIO COMBUSTIBILE All purpose heating solutions Soluzioni integrate per il riscaldamento All purpose heating

More information

TCR easy Plus Alarm. Operating Instructions

TCR easy Plus Alarm. Operating Instructions TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611 DT1-IK 2CSM204275R0611 DT1-IK/24V 2CSM204285R0611 DT1-IK/DCF 2CSM204295R0611 DT2-IK 2CSM204325R0611 System pro M GB -1- WEEKLY DIGITAL TIME SWITCH + PROGRAMMING KEY I -11- INTERRUTTORE ORARIO DIGITALE

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

RELAYS E ACCESSORI FUSIBILI E PORTAFUSIBILI

RELAYS E ACCESSORI FUSIBILI E PORTAFUSIBILI 6 RELAYS E ACCESSORI FUSIBILI E PORTAFUSIBILI relays and accessories fuses and fuseholders 103 MICRO RELAYS 12V. PER AUTO 12V micro relays for cars DIMENSIONI / dimensions: 26x15x23 mm COD. ART. 201006

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

LIGHTING and LIGHTING SYSTEMS

LIGHTING and LIGHTING SYSTEMS LIGHTING and LIGHTING SYSTEMS Introduction Lighting is an important area of opportunity for energy savings, since it is a large fraction of use of electricity in residential and commercial buildings. Lighting

More information

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com DuroSite TM Series LED High Bay Brochure for Industrial & Commercial Applications.dialight.com 1 DuroSite TM Series LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours Up to 79lm/

More information

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA

13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA 13/30 SERIES / SERIE 13/30 EIA 1 5/8 SERIES / SERIE EIA 1 5/8 EIA 1 5/8 CONNECTORS CONNETTORI EIA 1 5/8 2 Main Characteristics - Low reflection coefficient (up to 3 GHz) - Low IMD3 value (-162dBc) - Inner

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0

Technical Data. back-up time in minutes 100% load 6 7 0 5 6 0 5 0 50% load 15 18 0 15 16 0 15 0 The protectoq is a On-Line double conversion UPS-system according to IEC / EN 62040-3 (VFI-SS-111) with sinus wave output voltage in each operation mode, LCDindication, RS232 interface, USB-connection,

More information

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Fixed - Over/Under voltage limits, (0.75...1.2) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits Features 71.11.8.230.0010 71.11.8.230.1010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay

More information

SL42-xx SL42: Smart lighting controllers installation in the pole

SL42-xx SL42: Smart lighting controllers installation in the pole SL42: Smart lighting controllers installation in the pole SL42 controllers can drive electronic ballasts (DALI or 1 10V), magnetic ballasts in ON/OFF or in dimming. Based on LonWorks protocol, open and

More information

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES

English AUTOMATION SYSTEMS FOR SLIDING GATES. Operating and installation instructions SLIDE SERIES English AUTOMATION SYSTEMS FOR SLIDING GATES Operating and installation instructions SLIDE SERIES v.0 Rev /202 INDEX ) General Safety Regulations... pág. 0 2) Description... pág. 02 3) Technical Specifications...

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors

analog SENSORI INDUTTIVI ANALOGICI inductive analog sensors Sensori di prossimità induttivi con uscita analogica Inductive proximity sensors with analogue output a Caratteristiche principali Main features > Ampia scelta di dimensioni: M, M2 e M > Wide choice of

More information

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION

KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION KRONOS GA11 WEEKLY-PROGRAMMING DIGITAL CHRONOTHERMOSTAT FOR THE REMOTE CONTROL OF HOT AIR GENERATORS THROUGH BRAHMA INTERFACE BOARD APPLICATION The digital chronothermostat Brahma Kronos series integrates

More information

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch 2 Wire Electronic Time Delay Switch Cat No. DS1 2 Wire Slave Switch Cat No. DSS 3 Wire Electronic Time Delay Switch Cat No. DS2 Installation & Operating Instructions DS1/DSS Instructions for Installation

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

The most sustainable lighting solution. QL 85W Induction Lighting System

The most sustainable lighting solution. QL 85W Induction Lighting System The most sustainable lighting solution QL 85W Induction Lighting System QL Induction Lighting Systems QL induction lighting is used for professional, general and special lighting applications because of

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy. Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810 AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810 This Manual and the information contained therein is the property of AMI Marine (UK) Ltd. It must not be reproduced

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

T5 LongLast. GE Lighting DATA SHEET

T5 LongLast. GE Lighting DATA SHEET GE Lighting T5 LongLast DATA SHEET Linear Fluorescent Lamps T5 LongLast High Efficiency 14W, 21W, 28W, 35W T5 LongLast High Output 24W, 39W, 49W, 54W, 8W Product information T5 LongLast lamps are triphosphor

More information

PLA 44. Power quality analyzer. User and service manual. BMR trading

PLA 44. Power quality analyzer. User and service manual. BMR trading PLA 44 Power quality analyzer User and service manual version 1.2 BMR Lipovka 17 516 01 Rychnov n. Kn. 1 Tel: +420 774 415 703 Fax: +420 494 533 602 Content 1. Front panel...3 5.6.1. List of events...8

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

ENERGY EFFICIENT LIGHTING

ENERGY EFFICIENT LIGHTING ENERGY EFFICIENT LIGHTING Prof. Suryanarayana y Doolla IIT Bombay Dept. of Energy Science & Engineering Content 2 Basics of Illumination Types of light source, lighting Comparison of commercial lamps Energy

More information