1 Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel , Fax Ordered by: AMK-Collectra AG Bahnweg Nord 16 CH-9475 Sevelen Tel. +41 (081) Fax: +41 (081) Test Report No. C926LPEN Performance test according to EN :2006, Paragraph 6 Content: page 1 Description of Collector Technical Data of the Sample Sketch of Collector Specifications on Elements Photo of Collector Sketch of Collector Mounting Test Methods and Results Test of Thermal Performance Schematic of the Test Loop Power Output Incident Angle Factor Time Constant Effective Thermal Capacity Pressure Drop Observed Failures Remarks...12 page 1 of 12 pages
2 1 Description of Collector 1.1 Technical Data of the Sample Product information Manufacturer AMK-Collectra AG Model OPC 10 Type Evacuated tube collector Flow Direct flow Serial product Yes A complete set of technical Drawing number drawings is filed at the test institute Serial number Date of manufacture Physical parameters Gross length m Gross width m Gross heigth m Gross area m² Aperture area m² Absorber area m² Weight empty 33.0 kg Fluid capacity 1.4 l Construction Type Number of absorber elements Absorber pitch Number of hydraulically parallel tubes Number of thermally serial glazings Material of glazing(s) Thickness of glazing(s) Evacuated tube collector mm 10 1 Borosilicate glass 1.6 mm Heat transfer fluid (manufacturers recommendation) Type Water-antifreeze Specifications -- Flow range (manufacturers recommendation) Flow range l/h Rated flow rate 45 l/h Absorber Absorber element Evacuated double glass tube Length of absorber element mm Width of absorber element 36.8 mm Thickness of absorber element 1.6 mm Coating Cermet AlN / SS on Al Flowed through element Copper U-pipe Joining technique Heat conducting aluminum sheets Joining seam -- Installation On tilted roof In tilted roof On flat roof On flat roof with stand Facade Yes No No Yes Yes Casing and insulation Casing material Aluminium Sealing material -- Insulation material Glass wool Thickness (in mm) 30 Aperture dimensions m * m Limitations (manufacturer information) Max. temperature Not specified Max. operating pressure 10 bar Other -- Remarks on collector design -- Test schedule Test procedure EN12975:2006, Outdoor test Sample received Start of test End of test page 2 of 12 pages
3 1.2 Sketch of Collector 1.3 Specifications on Elements 1 Glazing Material: Borosilicate glass Thickness [mm]: Vacuum 3 Absorber Absorber element: Evacuated double glass tube Flow-through element: Copper U-pipe Length of element [mm]: 1437 Width of element [mm]: 36.8 Flow type: Parallel 3 Absorber coating Description: 4 Heat-conducting metal sheet Description: 5 U-tube Description: Cermet AlN / SS on Al Aluminum Copper 6 CPC reflector page 3 of 12 pages
4 1.4 Photo of Collector 1.5 Sketch of Collector Mounting page 4 of 12 pages
5 2 Test Methods and Results 2.1 Test of Thermal Performance Tests carried out according to EN : Deviations from this standard are indicated by the same formatting that is used for this clause. The reasons for the deviations are mentioned. 2.2 Schematic of the Test Loop Fig. 2.1: Test loop for efficiency measurements. page 5 of 12 pages
6 2.3 Power Output General Flow rate during test Fluid for tests Test method Geographical position of test site l/h 33.3 Vol-% ethylene glycol stationary (steady state) 47.2 N / 8.8 O, 417 m NN Collector tilt angle tracked (45±5) Collector azimuth angle tracked (0±48) Definition of efficiency η = Q A G Thermal output power of collector Q & Reference area Solar irradiance Solar irradiance on reference area Efficiency equation Temperature at collector inlet Temperature at collector outlet Ambient temperature A G A G η = η T in T ex T a * * 2 0 a1 Tm a2 G Tm Mean collector temperature T = ( T T ) 2 m in + Reduced collector temperature T = ( T T ) G * m m ex a Solar irradiance for efficiency diagrams G = 800 W/m² page 6 of 12 pages
7 2.3.2 Power output per collector unit Peak power Peak power W peak per collector unit for normal incident irradiation of 1000 Wm -2. W peak = 865 [W] Diagram 1000 Power output per collector unit for G = 1000 W/m T m - T a [K] Fig. 2.2: Power output per collector unit at irradiance G = 1000 W/m² Power output per collector unit Global irradiance G T m - T a G=400 W/m² G=700 W/m² G=1000 W/m² 10 K 329 W 589 W 848 W 30 K 294 W 554 W 813 W 50 K 257 W 516 W 776 W page 7 of 12 pages
8 2.3.3 Efficiency curve The efficiency curves with reference to the absorber-, aperture- and gross areas are indicated in addition to the requirements of the norm Collector efficiency for G = 800 W/m 2 Absorber Aperture Gross T m * [Km 2 /W] Fig. 2.3: Efficiency diagram for G = 800 W/m² Parameters for efficiency equation Reference area Absorber area Aperture area Gross area η 0 (-) a 1 (W/m²K) a 2 (W/m²K²) From repetitive measurements of a reference collector, we estimate the following dispersion for the efficiency measurement (standard deviation of the mean, multiplied with a coverage factor 2): At T m *=0.02: 0.27 Efficiency-%, at T m *=0.05: 0.44 Efficiency -%, at T m *=0.08: 0.62 Efficiency -%. page 8 of 12 pages
9 2.4 Incident Angle Factor Table of the Incidence Angle Modifier (IAM) K Θ (longitudinal) K Θ (transversal) Diagram of the Incidence Angle Modifier Incident Angle Modifier IAMT IAML Angle [ ] Fig. 2.4: Incident angle modifiers page 9 of 12 pages
10 2.5 Time Constant τ C = 250 s 2.6 Effective Thermal Capacity Determination according to EN :2006, Annex G.3 Determination based on transient behaviour of the collector. C eff,g3 = 59.9 kj/k (Effective thermal capacity of collector filled with fluid) Additional information: The thermal capacity was measured with the properties of Antifrogen N. For other fluids, the thermal capacity is calculated as follows: C eff,g3 = 1.4 l * density * specific heat capacity of fluid kj/k Determination according to EN :2006, Section Estimation based on material properties. C eff,6162 = 14.4 kj/k (Effective thermal capacity of collector filled with fluid) Additional information: The thermal capacity was measured with the properties of Antifrogen N. For other fluids, the thermal capacity is calculated as follows: C eff,6162 = 1.4 l * density * specific heat capacity of fluid kj/k page 10 of 12 pages
11 2.7 Pressure Drop Diagram 4500 Pressure drop in Pa C Fig. 2.5: Pressure drop as a function of volume flowrate Flowrate [l/h] Pressure drop at rated flowrate Conditions: T m = 20 C and dv/dt = 45 l/h p = 240 Pa Table of pressure drop data in Pa Conditions: T m = 20 C Flow rate [l/h] Pressure drop [Pa] page 11 of 12 pages
12 2.8 Observed Failures Details about failures that are rated as major failures according to paragraph of EN :2006. Absorber leakage or such deformation that permanent contact between absorber and cover is established. Breaking or permanent deformation of cover or cover fixing. Breaking or permanent deformation of collector fixing points or collector box. Loss of vacuum or low pressure (applicable for vacuum or subatmospheric collectors) Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Passed Passed Passed Passed Passed No major failures according to paragraph of EN :2006 were found for this collector. 3 Remarks This report must not be copied except in full. The test methods applied fulfil the requirements of EN12975:2006. The test results only refer to the tested collector sample. This test report is made according to the requirements of EN12975:2006. This test report fulfils the requirements of ISO Rapperswil, Dr. Andreas Bohren Head of SPF Testing Dipl.-Ing. Walter Gubler Test engineer page 12 of 12 pages
Test Report No. C1319LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Thermics S.r.l. Via dell'olmo
More informationTest Report No. C908LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Changzhou He Jia Solar Energy
More informationTest Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
More informationCollector test according to EN 12975-1,2:2006
Test Report: KTB Nr. 2007-07-en Collector test according to EN 12975-1,2:2006 for: Jiangsu sunrain solar energy co. ltd, P.R. China Brand name: TZ58-1800 Responsible for testing: Dipl.-Ing. (FH) K. Kramer
More informationUniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu
UniPlate Solar Collectors SOLAR SYSTEMS www.solarico.eu keep the sun in mind Solar energy has by far the highest theoretical potential of the earth s renewable energy sources. It is the most abundant energy
More informationHarness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector
NOW AVAILABLE! the new ASW-58A-22/30 Solar Thermal Collector The ASW-58A-22/30 series of collectors are available in 22 and 30 tube units. Other sizes are available upon request. Each unit comes complete.
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationCollector test according to EN 12975-1,2:2006
Test Report: KTB Nr. 2006-35-k-j-en Collector test according to EN 12975-1,2:2006 for: IMMERGAS S.p.A., Italia Brand name: Series Collettore Solare Piano CP4M and Collettore Solare Piano CP2M Responsible
More informationVITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
More informationData Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
More informationSOLAR POWERING OF HIGH EFFICIENCY ABSORPTION CHILLER. Final Report. Randy C. Gee
SOLAR POWERING OF HIGH EFFICIENCY ABSORPTION CHILLER Final Report Randy C. Gee SOLAR COOLING, LLC 1378 Charleston Drive P.O. Drawer 10 Sanford, NC 27331-0010 November 2004 PREPARED FOR THE U.S. DEPT. OF
More informationA comparison of three different collectors for process heat applications
A comparison of three different collectors for process heat applications S. Brunold, R. Frey, U. Frei SPF-ITR Solarenergie Prüf- und sstelle Ingenieurschule ITR Oberseestr. 10; CH-8640 Rapperswil Tel.:(+41)
More informationUNDERSTANDING AND USING COLLECTOR TEST STANDARD EN 12975
UNDERSTANDING AND USING COLLECTOR TEST STANDARD EN 12975 CONTENTS SUMMARY... 1 STANDARDIZATION REQUIREMENTS AND BENEFITS... 2 Standardized tests... 2 Random selection of test samples... 2 Requirements
More informationPRODUCTION OF DOMESTIC HOT WATER WITH SOLAR THERMAL COLLECTORS IN NORTH-EUROPEAN APARTMENT BUILDINGS
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 1, Jan-Feb 2016, pp. 58-66, Article ID: IJMET_07_01_007 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=1
More informationIntroduction to solar thermal technology
Introduction to solar thermal technology M.Sc. Research and Testing Centre for Thermal Solar Systems (TZS) Institute for Thermodynamics and Thermal Engineering (ITW) University of Stuttgart Pfaffenwaldring
More informationSolar thermal collectors for medium temperature applications: a comprehensive review and updated database
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 00 (2015) 000 000 www.elsevier.com/locate/procedia SHC 2015, International Conference on Solar Heating and Cooling for Buildings
More informationVIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal
More informationProfessional Report. Map section. Location of the system. Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m
Puulämmitys 6 x SF3 Location of the system Map section Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m This report has been created by: Samppa Takala Samppa Takala Nyrhintie 14 28760 Pori
More informationQuality Assurance in Solar Heating and Cooling Technology A GUIDE TO THE STANDARD EN 12975
Quality Assurance in Solar Heating and Cooling Technology A GUIDE TO THE STANDARD EN 12975 Quality Assurance in solar thermal heating and cooling technology keeping track with recent and upcoming developments
More informationPrice List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.
Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS
More information8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D. 2,391.9 kwh
Solar Colwood 2013 8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D Location of the system Canada Victoria Longitude: -123.37 Latitude: 48.42 Elevation: 40 m This report has been created by: MD Miroslav Danielka
More informationVicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.
Vicot Solar Air Conditioning V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.cn Cooling, heating, and domestic hot water. Return on investment
More informationVIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate
More informationEnergy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
More informationActive Solar Thermal Energy Applications in Buildings (Part 1)
Active Solar Thermal Energy Applications in Buildings (Part 1) Yerevan State University of Architecture and Construction INOGATE Programme New ITS Project, Ad Hoc Expert Facility (AHEF) Task AM-54-55-56
More informationSOLAR WATER HEATER USER AND INSTALLATION MANUAL
SOLAR WATER HEATER USER AND INSTALLATION MANUAL SOLAR WATER HEATER USER AND INSTALLATION MANUAL Non-pressure series solar water heater SZ58/1800-10 SZ58/1800-15 SZ58/1800-18 SZ58/1800-20 Index System
More informationINSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE
SUN & HEAT SOLAR PRODUCTS INSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE SOLAR DOMESTIC WATER HEATER THERMOSIPHON 150/2.5 (TYPICAL INSTRUCTIONS FOR A CLOSED LOOP THERMOSIPHONIC SYSTEM ON A FLAT
More informationDomestic Water Heating with Flat Collector
Domestic Water Heating with Flat Collector Dr. K.Boedecker This manual must be kept by the unit. Before operating the unit: - Read this manual. - All participants must be instructed on handling of the
More informationSOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER
SOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER SPF Institut für Solartechnik Prüfung Forschung HSR Hochschule Rapperswil, PF 1475, CH-8640 Rapperswil Tel.:
More informationV5001S. Kombi-S Shutoff Valve. Product specification sheet
V5001S Kombi-S Shutoff Valve Product specification sheet Application The V5001S Kombi-S shutoff valve is used to shutoff pipelines in residential or commercial hydronic heating and cooling systems. It
More informationECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
More informationALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device
Project No TREN/FP7EN/218952 ALONE small scale solar cooling device Collaborative Project Small or Medium-scale Focused Research Project DELIVERABLE D5.2 Start date of the project: October 2008, Duration:
More informationBER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric
More informationProcess Heat Collectors
IEA SHC-Task 33 and SolarPACES-Task IV: Solar Heat for Industrial Processes State of the Art within Task 33/IV Editors: Werner Weiss Matthias Rommel AEE - Institute for Sustainable Technologies Fraunhofer
More informationDispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationSolar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
More informationTechnical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace
Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace TECHNICAL SPECIFICATION Model RSK 2503(Z)-06A IR Belt Solar Cell Firing Furnace Temperature Range 1. Max Temperature.
More informationPerformance Test of Solar Assisted Solid Desiccant Dryer
Performance Test of Solar Assisted Solid Desiccant Dryer S. MISHA 1,2,*, S. MAT 1, M. H. RUSLAN 1, K. SOPIAN 1, E. SALLEH 1, M. A. M. ROSLI 1 1 Solar Energy Research Institute, Universiti Kebangsaan Malaysia,
More informationPRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)
PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold
More informationDistributed Solar-Thermal-Electric Generation and Storage Seth R. Sanders, Artin Der Minassians, Mike He EECS Department, UC Berkeley
Distributed Solar-Thermal-Electric Generation and Storage Seth R. Sanders, Artin Der Minassians, Mike He EECS Department, UC Berkeley Technology: rooftop solar thermal collector + thermal energy storage
More informationMap section. 87,390 kbtu
Closed-loop Solar System Closed-loop Solar Preheat with Back-Up Heater Location of the system Map section Richmond Longitude: -77.52 Latitude: 37.582 Elevation: 217 ft This report has been created by:
More informationCFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER
International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)
More informationDesign qualification and type approval of PV modules
Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance
More informationProfessional Report. US Solar Network Evanston residential DHW. 1 Gobi 410 001 Helio-Pak 2-4 persons. Map section. Location of the system
US Solar Network Evanston residential DHW 1 Gobi 410 001 Helio-Pak 2-4 persons Location of the system Map section Evanston, IL Longitude: -87.694 Latitude: 42.055 Elevation: 597 ft This report has been
More informationInstallation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
More informationSELECTIVE GLAZING FOR SUN CONTROL
SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level
More informationPERFORMANCE OPTIMIZATION OF HYBRID SOLAR HEATING SYSTEM USING THERMOELECTRIC GENERATOR
International Journal of Advanced Research in Engineering and Technology (IJARET) Volume 7, Issue 2, March-April 216, pp. 9-2, Article ID: IJARET_7_2_2 Available online at http://www.iaeme.com/ijaret/issues.asp?jtype=ijaret&vtype=7&itype=2
More informationPERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING LI CHUNYING DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG FEBRUARY 2012 CITY UNIVERSITY OF HONG KONG 香 港 城 市 大 學 Performance Evaluation of Water-flow
More informationEuropean technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationSOLAR HOT WATER SOLUTIONS stainless steel roof systems
SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationSolar Water Heaters. Three types of solar collectors are used for residential applications:
Solar Water Heaters Solar water heaters also called solar domestic hot water systems can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationLarge Scale Solar Thermal Systems Design Handbook
Large Scale Solar Thermal Systems Design Handbook First Edition - December 2009 A joint publication between Master Plumbers and Mechanical Services Association of Australia and Sustainability Victoria
More informationPV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY
PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY John Hollick Conserval Engineering Inc. 200 Wildcat Road Toronto Ontario jhollick@solarwall.com ABSTRACT PV modules generate electricity, but the electrical
More informationTesting and Performance of the Convex Lens Concentrating Solar Power Panel Prototype
Testing and Performance of the Convex Lens Concentrating Solar Power Panel Prototype Ankit S. Gujrathi 1, Prof. Dilip Gehlot 2 1 M.tech (2 nd Year), 2 Assistant Professor, Department of Mechanical Engg.,
More informationU.S. Department of Energy CSP Program Review
U.S. Department of Energy CSP Program Review Award Number: DE-FC36-08GO18035 Speaker: Amanda Steindorf Flagsol LLC May 17 19, 2011 Overview Project Objectives Project Summary to Date Project Impact on
More informationEnhancement of heat transfer of solar air heater roughened with circular transverse RIB
Enhancement of heat transfer of solar air heater roughened with circular transverse RIB Gurpreet Singh 1, Dr. G. S. Sidhu 2 Lala Lajpat Rai Institute of Engineering and Technology, Moga Punjab, India 1,2
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationExperimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window
Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Ahsan Iqbal #1, Alireza Afshari #2, Per Heiselberg *3, Anders Høj **4 # Energy and Environment, Danish Building Research
More informationTask 49/IV. Solar. Solar Process Heat for Production and Advanced Applications
Task 49/IV Process Heat for Production and Advanced Applications Operating Agent IEA SHC: Christoph Brunner AEE INTEC Gleisdorf, Austria c.brunner@aee.at PACES Contact: Klaus Hennecke DLR Research Köln,
More informationTesting Rules for Thermal Conductivity October 2015
Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.
More informationAMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun
AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun American Solar Water Heating Systems The American solar thermal system is more than just a solar water heater - it s the
More informationSection 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01
Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal
More informationThe following are just a few of the advantages that Techno-Solis offers you as a solar contractor: Contact Us!
Techno-Solis Solar Pool Heaters The Techno-Solis collector is the most durable solar panel on the market today. In production since 1976, our panels have been installed by Authorized Techno-Solis Dealers
More informationSmall-Scale Solar Heating and Cooling Systems
Contact Austria: AEE INTEC (www.aee-intec.at) France: Tecsol (www.tecsol.fr) Germany: Fraunhofer ISE (www.ise.fraunhofer.de) Greece: CRES (www.cres.gr) Italy: EURAC (www.eurac.edu) University of Bergamo
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationSolar Dehydration. Figure 2: Multiple Views of the Appalachian Solar Food Dryer
Dennis Scanlin, Marcus Renner, David Domermuth, & Heath Moody 1999 Dennis Scanlin, Marcus Renner, David Domermuth, and Heath Moody Above, Photo 1: Three identical solar food dryers for testing against
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationType 3353 Angle Seat Valve
Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat
More informationSolar Thermal Systems
Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationTANKJKT. Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS. Copyright 2015. By chemengsoftware.com
TANKJKT Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS Copyright 2015 By chemengsoftware.com Visit http://www.pipesizingsoftware.com/ for further information and ordering The following page
More informationDrain Back systems Made in Germany
Drain Back systems Made in Germany State-of-the-art technology Made in Germany Besides high-performance flat plate collectors the company STI also manufactures Drain Back systems. Many years of experience
More informationTECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)
TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC) Prepared by Committee for Technology Assessment and Analyzing the installation of Solar Water Heater Systems in Government
More informationThermostatic valve Type AVTA
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The
More informationTest Report. Nr. 1370-001-12 dated 16.02.2012. Sound Absorption Coefficient in the Reverberation Room. Lammengatan 2 SE-360 30 Lammhult Sweden
Test Report Nr. 1370-001-12 dated 16.02.2012 Sound Absorption Coefficient in the Reverberation Room Customer: Abstracta AB Lammengatan 2 SE-360 30 Lammhult Sweden Test Object: Arrangement of Acoustic Panels
More informationDouble Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.
Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationPeltier Application Note
Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationPerformance analysis of a Gamma type Stirling engine using three different solar concentrators
Performance analysis of a Gamma type Stirling engine using three different solar concentrators Krishanu Ganguly 1, Bhushan Dewangan *2, Sumit Banerjee 3, Rajeev Kumar 4 1 Krishanu Ganguly 2 Bhushan Dewangan
More informationHOT WATER SYSTEMS. www.thermann.com.au
HOT WTER SYSTEMS www.thermann.com.au GS HOT WTER SYSTEM The Thermann 4 star Gas hot water heater can suit almost any family type. With an adjustable thermostat for safety and efficiency it allows you to
More informationPassive and Active Solar Domestic Hot Water Systems
SOLAR CENTER INFORMATION NCSU Box 7401 Raleigh, NC 27695 (919) 515-3480 Toll Free 1-800-33-NC SUN Introduction Passive and Active Solar Domestic Hot Water Systems Solar hot water heaters can provide households
More informationstainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationEuropean test facilities for solar combisystems and heat stores
European test facilities for solar combisystems and heat stores A Report of IEA SHC - Task 26 Solar Combisystems December 2002 Harald Drück Peter Kovács Rodolphe Morlot Huib Visser Peter Vogelsanger European
More informationChapter 8: Heat Exchangers
Chapter 8: Heat Exchangers Section 8.1: Introduction to Heat Exchangers 8.1-1 (8-1 in text) Dry air at T a,in = 30 C, and atmospheric pressure is blown at V a = 1.0 m 3 /s through a cross-flow heat exchanger
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
More informationComparison of two calculation methods used to estimate cooling energy demand and indoor summer temperatures
Comparison of two calculation methods used to estimate cooling energy demand and indoor summer temperatures Kai Sirén and Ala Hasan Helsinki University of Technology, Finland Corresponding email: kai.siren@tkk.fi
More informationInstallation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
More informationCALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB
Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices
More informationSOLAR HEATING SYSTEMS. www.orkli.com
SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationFederalDemocratic RepublicofEthiopia
FederalDemocratic RepublicofEthiopia EDICTOFGOVERNMENT± Inordertopromotepubliceducationandpublicsafety, equaljusticeforal,abeterinformedcitizenry,therule oflaw,worldtradeandworldpeace,thislegaldocumentis
More informationbuilding applications copper - redefined
building applications copper - redefined copper - redefined The task The development of an innovative tube for the future: economical, environmentally friendly, ecological, completely safe and easy to
More informationField test of a novel combined solar thermal and heat pump system with an ice store
Field test of a novel combined solar thermal and system with an ice store Anja Loose Institute for Thermodynamics and Thermal Engineering (ITW), Research and Testing Centre for Thermal Solar Systems (TZS),
More information