Test Report No. C1319LPEN
|
|
- Amie Foster
- 8 years ago
- Views:
Transcription
1 Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel , Fax Ordered by: Thermics S.r.l. Via dell'olmo 47 IT Varmo Tel Fax: Test Report No. C1319LPEN Performance test according to EN :2006, Paragraph 6 Content: page 1 Description of Collector Technical Data of the Sample Sketch of the Collector Construction Specifications on Elements Photo of Collector Sketch of Collector Mounting Test Methods and Results Test of Thermal Performance Schematic of the Test Loop Power Output Incident Angle Factor Time Constant Effective Thermal Capacity Pressure Drop Observed Failures Remarks page 1 of 12 pages
2 1 Description of Collector 1.1 Technical Data of the Sample Product information Manufacturer Model Type Flow Serial product Drawing number Thermics S.r.l. 10 DTH-CPC Evacuated tube collector Direct flow Yes A complete set of technical drawings is filed at the test institute Serial number Date of manufacture Absorber Absorber element Length of absorber element Width of absorber element Thickness of absorber element Coating Flowed through element Joining technique -- Joining seam -- Evacuated double glass tube mm 47.0 mm 1.50 mm Cr-Al-N/Cu Coaxial copper pipe Physical parameters Gross length m Gross width m Gross heigth m Gross area m² Aperture area m² Absorber area m² Weight empty 49.0 kg Fluid capacity 2.4 l Construction Type Number of absorber elements Absorber pitch Number of hydraulically parallel tubes Number of thermally serial glazings Material of glazing(s) Thickness of glazing(s) Evacuated tube collector mm 10 1 Borosilicate glass 2.2 mm Heat transfer fluid (manufacturers recommendation) Type Water-Propyleneglycol Specifications -- Flow range (manufacturers recommendation) Flow range l/h Rated flow rate 120 l/h Installation On tilted roof In tilted roof On flat roof On flat roof with stand Facade Casing and insulation Casing material Sealing material Insulation material Yes No No Yes Yes Aluminium Silicone Rockwool compressionmoulded Thickness (in mm) 30 Aperture dimensions m * m Limitations (manufacturer information) Max. temperature Not specified Max. operating pressure 6 bar Other -- Remarks on collector design -- Test schedule Test procedure EN12975:2006, Outdoor test Sample received Start of test End of test page 2 of 12 pages
3 1.2 Sketch of Collector 1.3 Specifications on Elements 1 Glazing Material: Borosilicate glass Thickness [mm]: Heat-conducting metal sheet Description: 3 Coaxial tube Description: Aluminum Copper 4 Vacuum 5 Absorber Absorber element: Evacuated double glass tube Flow-through element: Coaxial copper pipe Length of element [mm]: 1741 Width of element [mm]: 47 Flow type: Parallel 5 Absorber coating Description: 6 CPC reflector Description: Cr-Al-N/Cu Aluminum page 3 of 12 pages
4 1.4 Photo of Collector 1.5 Sketch of Collector Mounting page 4 of 12 pages
5 2 Test Methods and Results 2.1 Test of Thermal Performance Tests carried out according to EN : Deviations from this standard are indicated by the same formatting that is used for this clause. The reasons for the deviations are mentioned. 2.2 Schematic of the Test Loop Fig. 2.1: Test loop for efficiency measurements. page 5 of 12 pages
6 2.3 Power Output General Flow rate during test Fluid for tests Test method Geographical position of test site l/h 33.3 Vol-% ethylene glycol stationary (steady state) 47.2 N / 8.8 O, 417 m NN Collector tilt angle tracked (45±5) Collector azimuth angle tracked (0±48) Definition of efficiency η Q A G Thermal output power of collector Q Reference area Solar irradiance Solar irradiance on reference area Efficiency equation Temperature at collector inlet Temperature at collector outlet Ambient temperature A G A G T in T ex T a * * 2 0 a1 Tm a2 G Tm Mean collector temperature T T T 2 Reduced collector temperature T T T G m * m in m ex a Solar irradiance for efficiency diagrams G = 800 W/m² page 6 of 12 pages
7 2.3.2 Power output per collector unit Peak power Peak power W peak per collector unit for normal incident irradiation of 1000 Wm -2. W peak = 1282 [W] Diagram 1400 Power output per collector unit for G = 1000 W/m T m - T a [K] Fig. 2.2: Power output per collector unit at irradiance G = 1000 W/m² Power output per collector unit T m - T a Global irradiance G G=400 W/m² G=700 W/m² G=1000 W/m² 10 K 485 W 869 W 1254 W 30 K 424 W 809 W 1193 W 50 K 359 W 743 W 1128 W page 7 of 12 pages
8 2.3.3 Efficiency curve The efficiency curves with reference to the absorber-, aperture- and gross areas are indicated in addition to the requirements of the norm Collector efficiency for G = 800 W/m 2 Absorber Aperture Gross T m * [Km 2 /W] Fig. 2.3: Efficiency diagram for G = 800 W/m² Parameters for efficiency equation Reference area Absorber area Aperture area Gross area 0 (-) a 1 (W/m²K) a 2 (W/m²K²) From repetitive measurements of a reference collector, we estimate the following dispersion for the efficiency measurement (standard deviation of the mean, multiplied with a coverage factor 2): At T m *=0.02: 0.27 Efficiency-%, at T m *=0.05: 0.44 Efficiency -%, at T m *=0.08: 0.62 Efficiency -%. page 8 of 12 pages
9 2.4 Incident Angle Factor Table of the Incidence Angle Modifier (IAM) K (longitudinal) K (transversal) Diagram of the Incidence Angle Modifier Incident Angle Modifier IAMT IAML Angle [ ] Fig. 2.4: Incident angle modifiers page 9 of 12 pages
10 2.5 Time Constant C = 502 s 2.6 Effective Thermal Capacity Determination according to EN :2006, Annex G3 Determination based on transient behaviour of the collector. C eff,g3 = kj/k (Effective thermal capacity of collector filled with fluid) Additional information: The thermal capacity was measured with the properties of Antifrogen N. For other fluids, the thermal capacity is calculated as follows: C eff,g3 = 2.4 l * density * specific heat capacity of fluid kj/k Determination according to EN :2006, Section Estimation based on material properties. C eff,6162 = 24.3 kj/k (Effective thermal capacity of collector filled with fluid) Additional information: The thermal capacity was measured with the properties of Antifrogen N. For other fluids, the thermal capacity is calculated as follows: C eff,6162 = 2.4 l * density * specific heat capacity of fluid kj/k page 10 of 12 pages
11 2.7 Pressure Drop Diagram 4000 Pressure drop in Pa C Fig. 2.5: Pressure drop as a function of volume flowrate Flowrate [l/h] Pressure drop at rated flowrate Conditions: T m = 20 C and dv/dt = 120 l/h p = 955 Pa Table of pressure drop data in Pa Conditions: T m = 20 C Flow rate [l/h] Pressure drop [Pa] page 11 of 12 pages
12 2.8 Observed Failures Details about failures that are rated as major failures according to paragraph of EN :2006. Absorber leakage or such deformation that permanent contact between absorber and cover is established. Breaking or permanent deformation of cover or cover fixing. Breaking or permanent deformation of collector fixing points or collector box. Loss of vacuum or low pressure (applicable for vacuum or subatmospheric collectors) Accumulation of humidity in form of condensate on the inside of the transparent cover of the collector exceeding 10% of the aperture area Passed Passed Passed Passed Passed No major failures according to paragraph of EN :2006 were found for this collector. 3 Remarks This report must not be copied except in full. The test methods applied fulfil the requirements of EN12975:2006. The test results only refer to the tested collector sample. This test report is made according to the requirements of EN12975:2006. This test report fulfils the requirements of ISO Rapperswil, Dr. Andreas Bohren Head of SPF Testing Dipl.-Ing. Walter Gubler Test engineer page 12 of 12 pages
Test Report No. C926LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: AMK-Collectra AG Bahnweg Nord
More informationTest Report No. C908LPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Changzhou He Jia Solar Energy
More informationTest Report No. C829QPEN
Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,
More informationCollector test according to EN 12975-1,2:2006
Test Report: KTB Nr. 2007-07-en Collector test according to EN 12975-1,2:2006 for: Jiangsu sunrain solar energy co. ltd, P.R. China Brand name: TZ58-1800 Responsible for testing: Dipl.-Ing. (FH) K. Kramer
More informationUniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu
UniPlate Solar Collectors SOLAR SYSTEMS www.solarico.eu keep the sun in mind Solar energy has by far the highest theoretical potential of the earth s renewable energy sources. It is the most abundant energy
More informationHarness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector
NOW AVAILABLE! the new ASW-58A-22/30 Solar Thermal Collector The ASW-58A-22/30 series of collectors are available in 22 and 30 tube units. Other sizes are available upon request. Each unit comes complete.
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationCollector test according to EN 12975-1,2:2006
Test Report: KTB Nr. 2006-35-k-j-en Collector test according to EN 12975-1,2:2006 for: IMMERGAS S.p.A., Italia Brand name: Series Collettore Solare Piano CP4M and Collettore Solare Piano CP2M Responsible
More informationVITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
More informationData Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list
VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol
More informationSOLAR POWERING OF HIGH EFFICIENCY ABSORPTION CHILLER. Final Report. Randy C. Gee
SOLAR POWERING OF HIGH EFFICIENCY ABSORPTION CHILLER Final Report Randy C. Gee SOLAR COOLING, LLC 1378 Charleston Drive P.O. Drawer 10 Sanford, NC 27331-0010 November 2004 PREPARED FOR THE U.S. DEPT. OF
More informationPrice List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.
Price List Rev.2 2010 AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza 50.006 (Spain) Tel.: 976302135 Fax: 976468085 www.aguidrovert.com info@aguidrovert.com SOMMARIO INDEX SOLAR SYSTEMS... page 10 COMPONENTS
More informationA comparison of three different collectors for process heat applications
A comparison of three different collectors for process heat applications S. Brunold, R. Frey, U. Frei SPF-ITR Solarenergie Prüf- und sstelle Ingenieurschule ITR Oberseestr. 10; CH-8640 Rapperswil Tel.:(+41)
More informationPRODUCTION OF DOMESTIC HOT WATER WITH SOLAR THERMAL COLLECTORS IN NORTH-EUROPEAN APARTMENT BUILDINGS
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 1, Jan-Feb 2016, pp. 58-66, Article ID: IJMET_07_01_007 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=1
More informationVIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collectors for the utilisation of solar energy Datasheet Part no. and prices: see pricelist VITOSOL 200-F Type SV2A/B and SH2A/B Flat-plate collector for vertical or horizontal
More informationUNDERSTANDING AND USING COLLECTOR TEST STANDARD EN 12975
UNDERSTANDING AND USING COLLECTOR TEST STANDARD EN 12975 CONTENTS SUMMARY... 1 STANDARDIZATION REQUIREMENTS AND BENEFITS... 2 Standardized tests... 2 Random selection of test samples... 2 Requirements
More informationQuality Assurance in Solar Heating and Cooling Technology A GUIDE TO THE STANDARD EN 12975
Quality Assurance in Solar Heating and Cooling Technology A GUIDE TO THE STANDARD EN 12975 Quality Assurance in solar thermal heating and cooling technology keeping track with recent and upcoming developments
More informationProfessional Report. Map section. Location of the system. Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m
Puulämmitys 6 x SF3 Location of the system Map section Valkkinen Longitude: 23.667 Latitude: 61.267 Elevation: 89 m This report has been created by: Samppa Takala Samppa Takala Nyrhintie 14 28760 Pori
More informationSolar thermal collectors for medium temperature applications: a comprehensive review and updated database
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 00 (2015) 000 000 www.elsevier.com/locate/procedia SHC 2015, International Conference on Solar Heating and Cooling for Buildings
More informationVicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.
Vicot Solar Air Conditioning V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: 86-531-8235 5576 Fax: 86-531-82357911 Http://www.vicot.com.cn Cooling, heating, and domestic hot water. Return on investment
More informationVIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy
VIESMANN VITOSOL 200-F Flat-plate collector for the utilisation of solar energy Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 13 VITOSOL 200-F Type SV2 and SH2 Flat-plate
More informationEnergy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
More informationINSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE
SUN & HEAT SOLAR PRODUCTS INSTRUCTIONS FOR USE, MAINTENANCE AND INSTALLATION OF THE SOLAR DOMESTIC WATER HEATER THERMOSIPHON 150/2.5 (TYPICAL INSTRUCTIONS FOR A CLOSED LOOP THERMOSIPHONIC SYSTEM ON A FLAT
More information8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D. 2,391.9 kwh
Solar Colwood 2013 8ah: 2xBlue-B ST300L 2.919MW SF56.5% 225L/D Location of the system Canada Victoria Longitude: -123.37 Latitude: 48.42 Elevation: 40 m This report has been created by: MD Miroslav Danielka
More informationIntroduction to solar thermal technology
Introduction to solar thermal technology M.Sc. Research and Testing Centre for Thermal Solar Systems (TZS) Institute for Thermodynamics and Thermal Engineering (ITW) University of Stuttgart Pfaffenwaldring
More informationV5001S. Kombi-S Shutoff Valve. Product specification sheet
V5001S Kombi-S Shutoff Valve Product specification sheet Application The V5001S Kombi-S shutoff valve is used to shutoff pipelines in residential or commercial hydronic heating and cooling systems. It
More informationActive Solar Thermal Energy Applications in Buildings (Part 1)
Active Solar Thermal Energy Applications in Buildings (Part 1) Yerevan State University of Architecture and Construction INOGATE Programme New ITS Project, Ad Hoc Expert Facility (AHEF) Task AM-54-55-56
More informationDomestic Water Heating with Flat Collector
Domestic Water Heating with Flat Collector Dr. K.Boedecker This manual must be kept by the unit. Before operating the unit: - Read this manual. - All participants must be instructed on handling of the
More informationInstallation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized
Installation Manual Gravity Solar Water Heater Evacuated Tube Integrated (Direct) System, unpressurized Gravity Solar System Installation Manual: This manual explains how to install a system of evacuated
More informationSolar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
More informationSOLAR WATER HEATER USER AND INSTALLATION MANUAL
SOLAR WATER HEATER USER AND INSTALLATION MANUAL SOLAR WATER HEATER USER AND INSTALLATION MANUAL Non-pressure series solar water heater SZ58/1800-10 SZ58/1800-15 SZ58/1800-18 SZ58/1800-20 Index System
More informationECOplus Solar Cylinder
TECHNICAL INFORMATION Solar Cylinder Wagner& Co Connection Options for CONVECTROL II The Effective Convection Brake Technically and fluidically optimized barriers separate the water cooled in the pipes
More informationPRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)
PRO-CLEAN Product description Specifications Technical Description Max. backup operating pressure Max. service water operating pressure 3 bar 6 bar Hot water connection " female thread* V4A (no..4) Cold
More informationALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device
Project No TREN/FP7EN/218952 ALONE small scale solar cooling device Collaborative Project Small or Medium-scale Focused Research Project DELIVERABLE D5.2 Start date of the project: October 2008, Duration:
More informationCFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER
International Journal of Advancements in Research & Technology, Volume 1, Issue2, July-2012 1 CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER ABSTRACT (1) Mr. Mainak Bhaumik M.E. (Thermal Engg.)
More informationBER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric
More informationDispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.
Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationPERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING
PERFORMANCE EVALUATION OF WATER-FLOW WINDOW GLAZING LI CHUNYING DOCTOR OF PHILOSOPHY CITY UNIVERSITY OF HONG KONG FEBRUARY 2012 CITY UNIVERSITY OF HONG KONG 香 港 城 市 大 學 Performance Evaluation of Water-flow
More informationArt.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
More informationSolar Thermal Systems
Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann
More informationSolar Water Heaters. Three types of solar collectors are used for residential applications:
Solar Water Heaters Solar water heaters also called solar domestic hot water systems can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationTechnical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace
Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace TECHNICAL SPECIFICATION Model RSK 2503(Z)-06A IR Belt Solar Cell Firing Furnace Temperature Range 1. Max Temperature.
More informationU.S. Department of Energy CSP Program Review
U.S. Department of Energy CSP Program Review Award Number: DE-FC36-08GO18035 Speaker: Amanda Steindorf Flagsol LLC May 17 19, 2011 Overview Project Objectives Project Summary to Date Project Impact on
More informationPerformance Test of Solar Assisted Solid Desiccant Dryer
Performance Test of Solar Assisted Solid Desiccant Dryer S. MISHA 1,2,*, S. MAT 1, M. H. RUSLAN 1, K. SOPIAN 1, E. SALLEH 1, M. A. M. ROSLI 1 1 Solar Energy Research Institute, Universiti Kebangsaan Malaysia,
More informationProcess Heat Collectors
IEA SHC-Task 33 and SolarPACES-Task IV: Solar Heat for Industrial Processes State of the Art within Task 33/IV Editors: Werner Weiss Matthias Rommel AEE - Institute for Sustainable Technologies Fraunhofer
More informationDistributed Solar-Thermal-Electric Generation and Storage Seth R. Sanders, Artin Der Minassians, Mike He EECS Department, UC Berkeley
Distributed Solar-Thermal-Electric Generation and Storage Seth R. Sanders, Artin Der Minassians, Mike He EECS Department, UC Berkeley Technology: rooftop solar thermal collector + thermal energy storage
More informationDesign qualification and type approval of PV modules
Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance
More informationSOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER
SOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER SPF Institut für Solartechnik Prüfung Forschung HSR Hochschule Rapperswil, PF 1475, CH-8640 Rapperswil Tel.:
More informationVdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationTask 49/IV. Solar. Solar Process Heat for Production and Advanced Applications
Task 49/IV Process Heat for Production and Advanced Applications Operating Agent IEA SHC: Christoph Brunner AEE INTEC Gleisdorf, Austria c.brunner@aee.at PACES Contact: Klaus Hennecke DLR Research Köln,
More informationProfessional Report. US Solar Network Evanston residential DHW. 1 Gobi 410 001 Helio-Pak 2-4 persons. Map section. Location of the system
US Solar Network Evanston residential DHW 1 Gobi 410 001 Helio-Pak 2-4 persons Location of the system Map section Evanston, IL Longitude: -87.694 Latitude: 42.055 Elevation: 597 ft This report has been
More informationExperimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window
Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Ahsan Iqbal #1, Alireza Afshari #2, Per Heiselberg *3, Anders Høj **4 # Energy and Environment, Danish Building Research
More informationPERFORMANCE OPTIMIZATION OF HYBRID SOLAR HEATING SYSTEM USING THERMOELECTRIC GENERATOR
International Journal of Advanced Research in Engineering and Technology (IJARET) Volume 7, Issue 2, March-April 216, pp. 9-2, Article ID: IJARET_7_2_2 Available online at http://www.iaeme.com/ijaret/issues.asp?jtype=ijaret&vtype=7&itype=2
More informationSELECTIVE GLAZING FOR SUN CONTROL
SUN CONTROL GLAZING SELECTIVE GLAZING FOR SUN CONTROL Sun Factor 1st level performance for direct solar energy Solar energy control Solar control coating Only if the glass is exposed to sun rays! 2nd level
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationDrain Back systems Made in Germany
Drain Back systems Made in Germany State-of-the-art technology Made in Germany Besides high-performance flat plate collectors the company STI also manufactures Drain Back systems. Many years of experience
More informationSOLAR HOT WATER SOLUTIONS stainless steel roof systems
SOLAR HOT WATER SOLUTIONS stainless steel roof systems RHEEM. SINCE 1937. Rheem has been manufacturing in Australia since 1937. Over seventy-five years later, Rheem is a household name and is as much a
More informationEuropean technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
More informationPassive and Active Solar Domestic Hot Water Systems
SOLAR CENTER INFORMATION NCSU Box 7401 Raleigh, NC 27695 (919) 515-3480 Toll Free 1-800-33-NC SUN Introduction Passive and Active Solar Domestic Hot Water Systems Solar hot water heaters can provide households
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationDouble Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.
Double Glazing Glass Energy Saving Solutions Harris Silicones & Glass (Pvt.) Company Introduction Pioneers of Silicone Sealants in Pakistan Manufacturing in collaboration with Momentive Performance Materials
More informationPV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY
PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY John Hollick Conserval Engineering Inc. 200 Wildcat Road Toronto Ontario jhollick@solarwall.com ABSTRACT PV modules generate electricity, but the electrical
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationHorizontal Pond Domestic Hot Water Heater
Horizontal Pond Domestic Hot Water Heater This is an experimental concept for a solar domestic water heater. It consists of a horizontal pond of water that is glazed on top and insulated on the bottom
More informationPeltier Application Note
Peltier Application Note Early 19th century scientists, Thomas Seebeck and Jean Peltier, first discovered the phenomena that are the basis for today s thermoelectric industry. Seebeck found that if you
More informationHOT WATER SYSTEMS. www.thermann.com.au
HOT WTER SYSTEMS www.thermann.com.au GS HOT WTER SYSTEM The Thermann 4 star Gas hot water heater can suit almost any family type. With an adjustable thermostat for safety and efficiency it allows you to
More informationstainless steel pre-assembled manifolds
TECHNICAL CATALOGUE stainless steel pre-assembled manifolds TEC ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationEnhancement of heat transfer of solar air heater roughened with circular transverse RIB
Enhancement of heat transfer of solar air heater roughened with circular transverse RIB Gurpreet Singh 1, Dr. G. S. Sidhu 2 Lala Lajpat Rai Institute of Engineering and Technology, Moga Punjab, India 1,2
More informationLarge Scale Solar Thermal Systems Design Handbook
Large Scale Solar Thermal Systems Design Handbook First Edition - December 2009 A joint publication between Master Plumbers and Mechanical Services Association of Australia and Sustainability Victoria
More informationMap section. 87,390 kbtu
Closed-loop Solar System Closed-loop Solar Preheat with Back-Up Heater Location of the system Map section Richmond Longitude: -77.52 Latitude: 37.582 Elevation: 217 ft This report has been created by:
More informationAMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun
AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun American Solar Water Heating Systems The American solar thermal system is more than just a solar water heater - it s the
More informationCALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB
Compact automatic flow rate regulator with polymer cartridge 127 series REGISTERED BS EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01166/09 GB Function The AUTOFLOW devices
More informationErgo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More informationThe following are just a few of the advantages that Techno-Solis offers you as a solar contractor: Contact Us!
Techno-Solis Solar Pool Heaters The Techno-Solis collector is the most durable solar panel on the market today. In production since 1976, our panels have been installed by Authorized Techno-Solis Dealers
More informationInstallation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
More informationKONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
More informationAluminium as Construction Material in Ammonia Refrigeration Cycles
Aluminium as Construction Material in Ammonia Refrigeration Cycles Experiences With Aluminium Compared to other metals, aluminium has only a brief history as an engineering material. While, about 150 years
More informationSOLAR HEATING SYSTEMS. www.orkli.com
SOLAR HEATING SYSTEMS www.orkli.com // 2 Orkli is one of the main European manufacturers of components for household appliances and innovative solutions for the comfort sector. Its corporate activity is
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationTANKJKT. Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS. Copyright 2015. By chemengsoftware.com
TANKJKT Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS Copyright 2015 By chemengsoftware.com Visit http://www.pipesizingsoftware.com/ for further information and ordering The following page
More informationField test of a novel combined solar thermal and heat pump system with an ice store
Field test of a novel combined solar thermal and system with an ice store Anja Loose Institute for Thermodynamics and Thermal Engineering (ITW), Research and Testing Centre for Thermal Solar Systems (TZS),
More informationSolar Absorption Cooling / Heating System for the Intelligent Workplace
Solar Absorption Cooling / Heating System for the Intelligent Workplace Ming Qu Sophie Masson Dr. David Archer IWESS Workshop Oct.4,2006 page1 Introduction IW solar cooling/heating system One -axis solar
More informationINSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360
INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360 IMPORTANT SAFETY INSTRUCTIONS WARNING! To reduce the risk of injury or death it is important to closely follow all of the following instructions.
More informationTest Report. Nr. 1370-001-12 dated 16.02.2012. Sound Absorption Coefficient in the Reverberation Room. Lammengatan 2 SE-360 30 Lammhult Sweden
Test Report Nr. 1370-001-12 dated 16.02.2012 Sound Absorption Coefficient in the Reverberation Room Customer: Abstracta AB Lammengatan 2 SE-360 30 Lammhult Sweden Test Object: Arrangement of Acoustic Panels
More informationTransient Analysis of Integrated Shiraz Hybrid Solar Thermal Power Plant Iman Niknia 1, Mahmood Yaghoubi 1, 2
Transient Analysis of Integrated Shiraz Hybrid Solar Thermal Power Plant Iman Niknia 1, Mahmood Yaghoubi 1, 2 1 School of Mechanical Engineering, Shiraz University, Shiraz, Iran 1, 2 Shiraz University,
More informationDevelopment of High-Speed High-Precision Cooling Plate
Hironori Akiba Satoshi Fukuhara Ken-ichi Bandou Hidetoshi Fukuda As the thinning of semiconductor device progresses more remarkably than before, uniformity within silicon wafer comes to be strongly required
More informationTesting and Performance of the Convex Lens Concentrating Solar Power Panel Prototype
Testing and Performance of the Convex Lens Concentrating Solar Power Panel Prototype Ankit S. Gujrathi 1, Prof. Dilip Gehlot 2 1 M.tech (2 nd Year), 2 Assistant Professor, Department of Mechanical Engg.,
More informationEXPERMENTATIONAL DATA ANALYSIS OF CHIMNEY OPERATED SOLAR POWER PLANT
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 1, Jan-Feb 2016, pp. 225-231, Article ID: IJMET_07_01_023 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=1
More informationsolarplus solar systems general features
SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationRules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force
More informationTechnical guide. Solar thermal systems
Technical guide Solar thermal systems Technical guide Solar thermal systems Viessmann Werke D-35107 Allendorf (Eder) Tel. +49 6452 70-0 Fax +49 6452 70-2780 www.viessmann.com 9449 829 GB 05/2009 Subject
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More information