Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test

Size: px
Start display at page:

Download "Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test"

Transcription

1 Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test Application of ASTM Standard Test Method F FSTC Report Food Service Technology Center Manager: Don Fisher Final Report, December 1999 Prepared by: Todd Bell Daniel Yap Fisher-Nickel, Inc. Danville, CA Prepared for: Peter Turnbull Pacific Gas and Electric Company Customer Energy Management Department San Francisco, California The information in this report is based on data generated at Pacific Gas & Electric Company s Food Service Technology Center.

2 Acknowledgments The establishment of a Food Service Technology Center reflects Pacific Gas and Electric Company s commitment to the food service industry. The goal of the research project is to provide Pacific Gas and Electric Company s customers with information to help them evaluate technically innovative food service equipment and systems and make informed equipment purchases regarding advanced technologies and energy sources. The project was the result of many people and departments working together within Pacific Gas and Electric Company and the support of the commercial equipment manufacturers who supplied appliances for testing. Pacific Gas and Electric Company s Food Service Technology Center is supported by its National Advisory Group, which includes California Café Restaurant Corporation California Energy Commission (CEC) California Restaurant Association (CRA) Darden Restaurants, Inc. Electric Power Research Institute (EPRI) Enbridge/Consumer Gas Gas Appliance Manufacturers Association (GAMA) Gas Research Institute (GRI) International Facility Management Association (IFMA) McDonald s Corporation National Restaurant Association Round Table Pizza Safeway, Inc. Underwriters Laboratories (UL) University of California, Berkeley (UC Berkeley) University of California, Riverside (CE-CERT) Policy on the Use of Food Service Technology Center Test Results and Other Related Information The Pacific Gas and Electric Company s Food Service Technology Center (FSTC) is strongly committed to testing food service equipment using the best available scientific techniques and instrumentation. The FSTC does not endorse equipment tested at the facility; test results reported herein should not be construed or interpreted as an endorsement of the equipment tested. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source. FSTC test results are made available to the general public through both Pacific Gas and Electric Company technical research reports and publications and are protected under U.S. and international copyright laws. In the event that FSTC data are to be reported, quoted, or referred to in any way in publications, papers, brochures, advertising, or any other publicly available documents, the rules of copyright must be strictly followed, including written permission from Pacific Gas and Electric Company in advance and proper attribution to Pacific Gas and Electric Company and the Food Service Technology Center. In any such publication, sufficient text must be excerpted or quoted so as to give full and fair representation of findings as reported in the original documentation from FSTC. Specific appreciation is extended to Kurt Creamer and Southbend Products for supplying the Food Service Technology Center with the Simple Steam, Model EZ-3, electric steamer for controlled testing in the appliance laboratory. Legal Notice This proprietary report was prepared by Pacific Gas and Electric Company. Neither Pacific Gas and Electric Company nor any of its employees: (1) makes any written or oral warranty, expressed or implied, including, but not limited to those concerning merchantability or fitness for a particular purpose; (2) assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, process, method, or policy contained herein; or (3) represents that its use would not infringe any privately owned rights, including, but not limited to, patents, trademarks, or copyrights This program is funded by the California utility customers and administrated by Pacific Gas and Electric Company under the auspices of the California Public Utilities Commission.

3 Contents Page Executive Summary... iii 1 Introduction Background Objectives Appliance Description and Operation Methods Setup and Instrumentation Revisions to the ASTM Test Method Measured Energy Input, Preheat and Idle Rate Ice Pans Full- and Light Load Efficiency Tests Green Peas Full- and Light Load Efficiency Tests Red Potatoes Full- and Light Load Efficiency Tests Results Manufacturer s Rated Input and Maximum Input Energy Rate Preheat and Idle Tests Cooking Tests Conclusions References Appendix A Glossary Appendix B Appliance Specifications Appendix C Results Reporting Sheets Appendix D Cooking Energy Efficiency Data i

4 Contents Tables: Page ES-1 Summary of the Performance... iv 1-1 Appliance Specifications Average Input, Preheat and Idle Test Results Cooking Energy Efficiency and Production Capacity Test Results Figures: Page ES-1 Steamer Cooking Energy Efficiency Under Full- and Light-Load Scenarios... v ES-2 Steamer Production Capacity... v 1-1 Southbend Simple Steam, model EZ The Simple Steam, EZ-3 Instrumented For Testing Products For Steamer Tests Hotel Pan with Thermocouple Probe for Bulk Temperature Determination Preheat and Idle Characteristics Steamer Cooking Energy Efficiency Under Full- and Light Load Scenarios Steamer Production Capacity ii

5 Executive Summary The Simple Steam by Southbend is one of the newest breed of self-contained steamers to hit the market. This countertop unit operates without a condensate drain and a water feed and features a near, closed-system design. The insulated cavity traps the steam and recycles the condensate, minimizing water usage and energy loss associated with condensate removal. Steam is generated on an as-need basis. The Food Service Technology Center (FSTC) tested the Simple Steam, model EZ-3, under the tightly controlled conditions of the American Society for Testing and Materials (ASTM) Standard Test Method for the Performance of Steam cookers. 1 Steamer performance is characterized by preheat energy consumption and duration, idle energy rate, cooking energy efficiency, production capacity, water consumption and condensate temperature from product testing. The spectrum of test products includes: full-load ice pans, light-load ice pans, full-load frozen green peas, light-load frozen green peas, full-load red potatoes and light-load red potatoes. Since the Simple Steam is without a condensate drain, the measurement of condensate temperature was not applied. In general, water usage was less than 2.5 gallons per test day. A summary of the test results is presented in Table ES-1. Figure ES-1 illustrates the Simple Steam, Model EZ-3, cooking energy efficiency for different cooking scenarios. The production capacities are shown in Figure ES-2. FSTC Manager Senior Program Manager iii

6 Executive Summary Table ES-1. Summary of the Performance: Southbend Simple Steam, Model EZ-3. Preheat and Idle Rated Energy Input Rate (kw) 8.3 Measured Energy Input Rate (kw) 8.0 Preheat Time (min) 8.7 Preheat Energy (kwh) 1.2 Idle Energy Rate (kw) 0.9 Full-Load Ice Pans (3 pans) Cook Time (min) 20.3 Cooking Energy Efficiency (%) 89.5 Production Capacity (lb/h) 71.0 Light-Load Ice Pans (1 pan) Cook Time (min) 8.3 Cooking Energy Efficiency (%) 85.9 Full-Load Frozen Green Peas (3 pans) Cook Time (min) 21.4 Cooking Energy Efficiency (%) 86.7 Production Capacity (lb/h) 67.2 Light-Load Frozen Green Peas (1 pan) Cook Time (min) 11.8 Cooking Energy Efficiency (%) 74.5 Full-Load Red Potatoes (3 pans) Cook Time (min) 23.5 Cooking Energy Efficiency (%) 69.0 Production Capacity (lb/h) 61.4 Light-Load Red Potatoes (1 pan) Cook Time (min) 21.6 Cooking Energy Efficiency (%) iv

7 Executive Summary Ice Pans 89.5% Peas 86.7% Ice Pan 85.9% Figure ES-1 Steamer Cooking Energy Efficiency Under Full- and Light Load Scenarios. Efficiency (%) Potatoes 69.0% Peas 74.5% Potatoes 41.5% 0 Full Load (3 pans) Light Load (1 pan) Figure ES-2. Steamer Production Capacity. Production Capacity (lb/h) lb/h 67.2 lb/h 61.4 lb/h 0 Ice Pans Peas Potatoes v

8 1 Introduction Background Steaming provides a fast-cook option for preparing large quantities of food while retaining vital nutrients in the cooked product. Beyond the capital cost, steamers should be evaluated with regard to long-term performance and operational costs characterized by cooking energy efficiency, production capacity and water consumption. With support from the Electric Power Research Institute (EPRI) and the Gas Research Institute (GRI), Pacific Gas and Electric Company s Food Service Technology Center (FSTC) developed a uniform testing procedure to evaluate the performance of gas and electric steam cookers. This test procedure was submitted to the American Society for Testing and Materials (ASTM) and accepted as a standard test method in December In keeping with ASTM s policy that a standard be periodically reviewed, the FSTC revised the steamer test method in February 1999 under the Designation F (originally published as F ). Modification to the test method includes replacing the ice load test with frozen green peas to capture real-world application and reducing the three loading scenarios to two. Pacific Gas & Electric Company s Development and Validation of a Uniform Testing Procedure for Steam Cooker documents the developmental procedures and test results of several gas and electric steamers. 3 The Simple Steam, model EZ-3, is a countertop steamer manufactured by Southbend, a Middleby Company. The steamer features a self-contained design that eliminates external water hookup and condensate drain. Benefit claims include ease in installation, portability, and reduction in operational cost from water usage, energy usage and maintenance

9 Introduction Objectives The objective of this report is to examine the operation and performance of the Southbend Simple Steam, model EZ-3, under the controlled conditions of the ASTM Standard Test Method. The scope of this testing is as follows: 1. Verify that the appliance is operating at the manufacturer s rated energy input. 2. Determine the preheat duration and energy consumption of the steamer. 3. Measure the idle energy rate. 4. Determine the cooking energy efficiency under six scenarios: full-load ice pans (3 pans), light-load ice pans (1 pan), full-load frozen green peas (3 pans), light-load frozen green peas (1 pan), full-load red potatoes (3 pans) and light-load red potatoes (1 pan). 5. Determine the production capacity, water consumption rate and condensate temperature of each loading scenario. Appliance Description and Operation The Simple Steam is a stainless-steel, pressureless steamer powered by an 8- kw electric heating element. The steamer does not require water connections, only an electrical connection. The cooking chamber can accommodate six 12" x 20" x 1" pans, three 12" x 20" x 2½" pans or two 12" x 20" x 4" pans. The unit is turned on and water is manually added at the beginning of the day. Steam is generated within the food compartment on an as-need basis. During non-cooking events, the unit maintains a low-power idle. At the end of the day, the unit can be turned off and drained. The glossary in Appendix A provides a quick reference to the terms used in this report. Appliance specifications are listed in Table 1-1, and the manufacturer s literature is in Appendix B

10 Introduction Table 1-1. Appliance Specifications. Manufacturer Southbend, a Middleby Company. Model Generic Appliance Type Rated Input Technology Controls Construction Compartment Capacity Dimensions Simple Steam, EZ-3. 1-compartment, pressureless, electric, steamer. 8 kw Boiler-less steamer with naturalconvection. Main ON / OFF lever. 60-Minute Timer. Automatic Operation. Check Water Level Light. Exterior: Type 304 Stainless Steel with #4 Sanitary Finish. Interior: Type 304 Stainless Steel. 12 (12" x 20" x 1" ) pans 3 (12" x 20" x 2½" ) pans 2 (12" x 20" x 4" ) pans 16" x 21" x 28 3 / 8 " (W H D) Figure 1-1. Southbend Simple Steam, model EZ

11 2 Methods Setup and Instrumentation The steamer was installed in accordance with the manufacturer s instruction on a metal table under a 4-foot-deep canopy hood, with the lower edge of the hood 6 feet, 6 inches above the floor and a minimum of 6 inches inside the vertical front edge of the hood. The exhaust ventilation operated at a nominal rate of 150 cfm per linear foot of hood with the ambient temperature maintained between 75 ± 5 F. All test apparatus were installed in accordance with Section 9 of the ASTM test method. 1 Power and energy were measured with a watt/watt-hour transducer that generated an analog signal for instantaneous power and a pulse for every 10 Wh. The transducer and thermocouples were connected to a computerized data acquisition unit that recorded data every 5 seconds. A voltage regulator, connected to the steamer, maintained a constant voltage for all tests. Figure 2-1 shows the Simple Steam instrumented with the data acquisition system and voltage regulator during an actual test. Figure 2-1. The Simple Steam EZ-3 Instrumented For Testing

12 Methods Revisions to the ASTM Test Method The steam cooker test method, originally published as F , has been revised as F The ice-load test, due to its simplicity, repeatability, and reproducibility, was applied during the developmental phase of the test procedure as a quick indicator of steamer efficiency and productivity. However, ice-load test results do not always mirror the results of food products, particularly with respect to real-world cook times and associated production capacities. The F test method lists the ice-load test as an optional procedure. The potato tests remain in the test method with two modifications. The method specified whole, U.S. No. 1, size B, red potatoes with an average weight of 0.14 ± 0.02 lb. Repetition of tests showed a higher average weight of around 0.16 lb. The revised test method calls for red potatoes weighing 0.16 ± 0.02 lb. The prescribed cook temperature of 205 F is high since the maximum attainable temperature of steam under atmospheric pressure is 212 F. Qualitative tests, using texture, taste, and consistency as criteria, showed that potatoes are cooked to an acceptable doneness at 195 F. The temperature of 195 ± 2 F was adopted as the potato cook temperature. The three-loading scenarios described in the test method have been reduced to two scenarios (full- and light-load tests). The full-load test determines the steamer s peak cooking energy efficiency and production capacity while the light-load test (1 pan) evaluates partial-load performance. Full- and light-load tests of frozen green peas are incorporated into the ASTM test method as a replacement for the ice-load tests. Since probing proves difficult and erroneous in measuring temperature of the small-sized green peas, a water-bath calorimeter is utilized to measure the final bulk temperature of the cooked green peas Figure 2-2 shows the spectrum of products tested on the Simple Steam: ice pans, frozen green peas, and red potatoes

13 Methods Figure 2-2. Products For Steamer Tests: Ice Pans (Optional), Frozen Green Peas and Red Potatoes. Measured Energy Input, Preheat and Idle Rate The energy input rate was determined by measuring the energy consumed by the steamer during a full preheat cycle. The maximum power draw during this period was reported as the measured energy input rate. Preheat tests recorded the time and energy required for the steamer to reach operating temperature from a cold start, as when turned on for the first time in a day. Recording began when the steamer was turned on and ended when it s elements first cycled off. An hour after the preheat cycle, idle energy consumption was monitored for a 2-hour period. Ice Pans Fulland Light Load Efficiency Tests Standard, solid, stainless-steel hotel pans (12" x 20" x 2½") provided the vessel for ice-pan testing. The ice/water temperature was measured with a type-t thermocouple probe welded to the center of the pan with the tip of the probe 5 / 8 " from the bottom (see Figure 2-3). Eight pounds of water (± 0.2 lb) were placed into each thermocoupled pan and frozen to 0 ± 5 F. Ice pans were loaded according to the loading scenario outlined by Table 1 of the ASTM steamer test method. Ice/water temperatures, energy input rate, Watt-hours, water consumption, and condensate temperature were monitored during the cooking process. The test ended when the average temperature of the ice pans reached 180 F

14 Methods Figure 2-3. Hotel Pan With Thermocouple Probe for Bulk Temperature Determination. Green Peas Fulland Light Load Efficiency Tests Individually flashed-frozen, grade A green peas represented one of two food products for steamer performance testing. Standard, perforated, stainlesssteel hotel pans (12" x 20" x 2½") are specified for cooking the green peas. The Simple Steam required 3 pans of green peas for a full load, while 1 pan, placed on the center rack of the steamer cavity, is required for a light load, each pan containing 8.0 ± 0.2 lb of green peas. Pre-weighed green peas in perforated pans were stored in sealed plastic bags at 0 ± 5 F for at least 24 hours. The pans of peas were transferred into an insulated box and transported to the testing location where the plastic bags were removed, and the pan(s) of green peas were loaded into the steamer according to the loading time prescribed in section of the ASTM test method

15 Methods Red Potatoes Full- and Light Load Efficiency Tests Freshly packed, size B, red potatoes served as the second food product for steamer performance testing. Again, the Simple Steam required 3 pans of red potatoes for a full load and 1 pan for a light load, each pan containing 8.0 ± 0.2 lb. The red potatoes were loaded into perforated pans prior to the test and stabilized to a room temperature of 75 ± 5 F. The potatoes were cooked to 195 ± 2 F using a predetermined cook time. The final bulk temperature was determined by randomly probing potatoes using a hand-held digital thermocouple meter within 3 minutes after cooking was terminated. For the food-load scenarios, iterative cooking time determination tests were required to establish the time necessary for the food product to reach the doneness temperature of 180 ± 2 F (for frozen green peas) and 195 ± 2 F (for red potatoes). The testing process followed this sequence: three replicates full-load green pea test, three replicates of the light-load green pea test, three replicates full-load red potatoes test and three replicates of the light-load red potatoes test. The replicates ensured that the reported cooking energy efficiency and production capacity results had an uncertainty of less than ±10%. The results from each test run were averaged, and the absolute uncertainty was calculated based on the standard deviation of the results. The ASTM results reporting sheets appear in Appendix C, and the cooking energy efficiency data sheets appear in Appendix D

16 3 Results Manufacturer s Rated Input and Maximum Energy Input Rate Measured energy input rate and the manufacturer s nameplate value were compared prior to any testing to ensure that the steamer was operating within its specified parameters. The Simple Steam drew a maximum input rate of 8.02 kw, 3.4% lower than the nameplate rate of 8.3 kw, but within the 5% tolerance of the ASTM standard. Preheat and Idle Tests Preheat Energy and Time The cavity was manually filled with 2.5 gallons of water at 70 ± 5 F. The preheat consumed 1.8 kwh during the 8.7 min period. Idle Energy Rate Following the preheat period, the steamer stabilized for one hour. Thereafter, the energy consumption was monitored over a 2-hour period and the idle energy rate was calculated to be 0.9 kw. Test Results Figure 3-1 shows the energy input rate in conjunction with the compartment temperature during the preheat and idle test. At cold-start, full energy input was applied to the bring the steamer up to ready-to-cook mode. During the idle, the heating element periodically powered-up to maintain the cooking compartment temperature at around 212 F

17 Results Figure 3-1. Preheat and Idle Characteristics. Energy Input Rate (kw) Energy Input Rate 225 Compartment Temperature Time (min) Compartment Temperature ( F) Rated energy input, preheat energy and idle rate test results are summarized in Table 3-1. Table 3-1. Average Input, Preheat and Idle Test Results. Rated Energy Input Rate (kw) 8.3 Measured Energy Input Rate (kw) 8.02 Preheat Time (min) 8.7 Energy (kwh) 1.8 Idle Energy Rate Energy Rate (kw)

18 Results Cooking Tests The steamer was tested with three test products under two loading scenarios: full-load ice pans (3 pans), light-load ice pan (1 pan), full-load green peas (3 pans), light-load green peas (1 pan), full-load red potatoes (3 pans), and light-load red potatoes (1 pan). The energy consumption, elapsed cook time, ambient temperature and product temperature were monitored for the duration of each test at five-second intervals. The Simple Steam does not employ a separate boiler, water connection or drain. Therefore, water consumption and condensate temperature were not monitored. Two and a half gallon of water was poured into both the trough above the door and the bottom of the cooking compartment before testing began. The steamer was emptied at the end of the day as directed by the manufacturer s instructions. Typical water usage was 2.5 gallons per test day. Full- and Light-Load Ice-Pan Test The ice-pan tests were intended to emulate cooking frozen vegetables, while better meeting three essential testing criteria (repeatability, reproducibility, and simplicity). For a full load, the Simple Steam heated the three ice pans to an average temperature 180 F with a cook time of 20.3 minutes, delivering 89.5% energy efficiency and 71.0 lb/h production capacity. Typically, steamers are not loaded to full capacity. The light-load test emulates such a cooking scenario with a single pan placed in the middle rack of the compartment. The cook time for a single ice pan was reduced to a repeatable 8.3 minutes. The one-pan loading scenario also reduced cooking energy efficiency and productivity, 85.9% and 57.9 lb/h, respectively

19 Results Full- and Light-Load Green Peas Test Moisture content of the frozen green peas was 81% by weight corresponding to specific heats (Cp) of 0.44 Btu/lb F for frozen and 0.85 Btu/lb F for thawed peas. 3 The Simple Steam required 21.4 minutes to cook the full load of frozen green peas with a cooking energy efficiency of 86.7% and production capacity of 67.2 lb/h. The light-load test required an average of 11.8 minutes when cooking a single pan of frozen green peas. Cooking energy efficiency and productivity were determined to be 74.5% and 40.8 lb/h, respectively. Full- and Light-Load Potatoes Test The red potatoes contained 84% moisture by weight with the specific heat (Cp) of 0.87 Btu/lb F. 3 A full-load of potatoes averaged 23.5 minutes to reach a bulk cook temperature of F. The cooking efficiency and production capacity were 69.0% and 61.4 lb/h, respectively. The single pan of red potatoes needed 21.6 minutes to achieve an average bulk temperature of F. The light-load potato test lowered the energy efficiency to 41.5% and productivity to 22.3 lb/h. Result Discussion The rate at which steam condenses on food depends on the surface temperature and area of the food. Therefore, frozen green peas (at 0 F) and red potatoes (at room temperature) represent two extremities in steam cooking. Frozen green peas, having large surface area to weight ratio, promote condensation. The energy transfer from steam to frozen food is high, resulting in greater cooking energy efficiency and productivity. Potatoes are tough to cook due to the slow nature of condensation

20 Results For both the full- and light-load scenarios, a large reduction in steamer cooking efficiencies were observed when comparing frozen green peas to fresh red potatoes: full load (86.7% % = 17.7%) and light load (74.5% % = 33.0%). Appendix D lists the physical properties and measured values of each test run. Using the detailed equations provided in section 11 of the steamer ASTM Standard Test Method, the cooking energy efficiencies can readily be calculated. Table 3-2 summarizes the Simple Steam s performance. Figures 3-2 and 3-3 compare these results in a graphical format. Table 3-2. Cooking Energy Efficiency and Production Capacity Test Results. Full-Load Ice Pans Light-Load Ice Pans Full-Load Peas Light-Load Peas Full-Load Potatoes Light-Load Potatoes Number of Pan(s) Cook Time (min) Energy Input Rate (kw) Energy Efficiency (%) Production Rate (lb/h)

21 Results Ice Pans 89.5% Peas 86.7% Ice Pan 85.9% Efficiency (%) Potatoes 69.0% Peas 74.5% Potatoes 41.5% Figure 3-2. Steamer Cooking Energy Efficiency Under Full- and Light Load Scenarios Full Load (3 pans) Light Load (1 pan) Production Capacity (lb/h) lb/h 67.2 lb/h 61.4 lb/h Figure 3-3. Steamer Production Capacity Ice Pans Peas Potatoes

22 4 Conclusions The Southbend Simple Steam, Model EZ-3, is amongst the top energy efficient countertop steamers tested at the Food Service Technology Center. By eliminating the water feed and condensate drain, water usage and energy consumption is greatly reduced. Steam is forced to condense on the food product instead of escaping down the drain. The lack of a separate boiler eliminates calcium carbonate problems and expensive chemical costs. The EZ-3 is highly efficient in transferring energy into fast-cook food product such as frozen green peas. For a full load, 86.7% of the total consumed energy went into heating the food and for a light load, 74.5%. Also, the EZ-3 performed well in steaming hard-to-cook product such as whole red potatoes: 69.0% for full load and 41.5% for light load

23 5 References 1. American Society for Testing and Materials Standard Test Method for the Performance of Steam Cookers. ASTM Designation F , in Annual Book of ASTM Standards, Philadelphia: American Society for Testing and Materials. 2. American Society for Testing and Materials Standard Test Method for the Performance of Steam Cookers. ASTM Designation F , in Annual Book of ASTM Standards, Philadelphia: American Society for Testing and Materials. 3. Food Service Technology Center Development and Application of a Uniform Testing Procedure for Steam Cookers. Report Product and Services Department. San Francisco, California: Pacific Gas and Electric Company. 4. American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc ASHRAE Handbook. Refrigeration Systems and Applications. I-P Edition. Chapter 25: Commodity Storage Requirements. Atlanta, Georgia. 5. Foodservice Equipment Reports. Lab Time! 3 Steamers Take the Test. October Vol. 1. No. 10. Pp Gill Ashton Publishing, L.L.C, Ill

24 A Glossary Boiler Self-contained electric, gas, or steam coil powered vessel wherein water is boiled to produce steam for the steam cooker. Also called a steam generator. Boiler Idle Energy Rate Idle Energy Rate Idle Rate Idle Energy Consumption Rate Rate of energy consumed by the steam cooker while maintaining boiler operating pressure or temperature with no cooking taking place. Boiler Preheat Preheat Process of bringing the boiler water from potable supply temperature to operating temperature (pressure). Boiler Preheat Duration Preheat Time Preheat Period Total time required for preheat, from preheat initiation at controls to when the steam cooker is ready to cook. Boiler Preheat Energy Preheat Energy Consumption Amount of energy consumed by the steam cooker during a preheat. Boiler Preheat Energy Rate Preheat Energy Rate The rate of appliance energy consumption while it is preheating to a predetermined temperature. Condensate A mixture of condensed steam and cooling water, exiting the steam cooker and directed to the floor drain. Condensate Temperature The temperature at which the condensate enters the floor drain. Cooking Energy Efficiency Energy Efficiency Quantity of energy imparted to the specified food product expressed as a percentage of energy consumed by the steam cooker during the cooking event. Cooking Energy Rate Cooking Energy Consumption Rate Average rate of energy consumption (kbtu/h or kw) during the cooking energy efficiency test. Refers to any loading scenario in the ice, pea or potato load tests. Cook Time Cooking Period The period of time that the steamer is used for cooking. Energy Input Rate Peak rate at which a steamer consumes energy, typically reflects during preheat. Frozen Green Peas Load 12 x 20 x 2½ in. (300 x 500 x 65 mm) hotel pan filled with 8.0±0.2 lb (3630±90 g) of frozen, grade A, green peas subsequently frozen to 0±5 F (-18±2 C). One of two food product used to determine cooking energy efficiency and production capacity A-1

25 Glossary High-Pressure Steam Cooker Steam cooker wherein cooking compartment operates between 10 and 15 psig (ASTM F Classification Type III). Idle Energy Consumption Idle Energy Use The amount of energy consumed by an appliance operating under an idle condition over the duration of an idle period. Ice Load 12 x 20 x 2½ in. (300 x 500 x 65 mm) hotel pan filled with 8.0±0.2 lb (3630±90 g) of water and subsequently frozen to 0±5 F (-18±2 C). This is used to simulate a food product load in the ice load cooking energy efficiency and production capacity test. Low-Pressure Steam Cooker Steam cooker wherein cooking compartment operates between 3 and 9.9 psig (ASTM F Classification Type II). Maximum energy input rate Measured Energy Input Measured Peak Energy Input Rate Peak Rate of Energy Input Peak rate at which an appliance consumes energy. Potato Load 12 x 20 x 2½ in. (300 x 500 x 65 mm) hotel pan filled with 8.0±0.2 lb (3.6±0.1 kg) of fresh, whole, US No. 1, size B, red potatoes. One of two food product used to determine cooking energy efficiency and production capacity. Pressureless Steam Cooker Steam cooker wherein cooking compartment operates between 0 and 2.9 psig (ASTM F Classification Type I). Production Capacity Maximum rate (lb(kg)/h) at which steam cooker can bring the specified food product to a specified "cooked" condition. Production Rate Rate (lb(kg)/h) at which steam cooker brings the specified food product to a specified "cooked" condition. Rated Energy Input Rate Input Rating (ANSI definition) Nameplate Energy Input Rate Rated Input The maximum or peak rate at which an appliance consumes energy as rated by the manufacturer and specified on the nameplate. Steam Cooker Cooking appliance wherein heat is imparted to food in a closed compartment by direct contact with steam. The compartment can be at or above atmospheric pressure. The steam can be static or circulated. Water Consumption Water consumed by the steam cooker. Includes both water used in the production of steam and cooling water (if applicable) for condensing/cooling unused steam A-2

26 B Appliance Specifications Appendix B includes the product literature for the Southbend Simple Steam, model EZ-3, steamer B-1

27 COUNTERTOP STEAMER A Middleby Company SIMPLE STEAM - 3 AND 5 PAN Standard Features - Stainless Steel Construction - Available in 3 and 5 Pan - Boilerless Design - Requires no routine maintenance - No Water Connection - Equipped with Drain pan - NO drain required - Low Water and Energy Usage - Simple ON/OFF Controls - Front Serviceable - No routine deliming - Field reversible door - Zero side clearance - Produces steam on demand required by product being cooked - One year Parts and Labor Warranty EZ-3 EZ-3 (3 Pan); EZ-5 (5 Pan) EZ-5 Job Item# Exterior Finish: 304 stainless steel finish with #4 sanitary finish. Interior Finish: 304 Stainless steel. Fully Insulated cooking compartment Power Source: Electric. One power source for controls and elements as well as one ground wire. A positive ground connection is essential. Controls: ON/OFF Lever: In the OFF position the power is off and the drain valve is open. In the ON position, the power is on ad the drain valve is closed. STANDARD CONSTRUCTION SPECIFICATIONS 60-Minute Timer: Time can be set between 1 and 60 minutes. When the time expires, buzzer sounds. Buzzer can be disabled by turning knob to manual position. Timer has no effect on the operation of the steamer. Automatic Operation: Steam in only generated when required by food being cooked. With no food in the cavity, the unit idles at operating temperature. CHECK WATER LEVEL Light: Indicates that the cavity does not have sufficient water. Water can be added through the trough over the door without opening the door, if desired. Legs: 4 stainless steel adjustable legs WATER QUALITY STATEMENT Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines: Total dissolved solids - less than 60 PPM Total alkalinity - less than 20 PPM Silica - less than 13 PPM Chlorine -less than 1.5 PPM ph Factor Water which fails to meet these standards should be treated by installation of water conditioner. FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY Form EZ A Middleby Company 07/04 Printed in USA

28 Models: EZ-3 EZ-5 2-1/2" (63) 16-1/2" (419) 30-1/2" (775) Height (see table below) 2" (51) 4" Adjustable Legs Dimensions: in (mm) FRONT VIEW SIDE VIEW TOP VIEW = Electrical Connection Terminal Block M odel Height* I nterior Dimensions Pan Capacity* * Width Depth H eight 1 " 2.5" 4" Width Crate Dimensions Depth Height Crate Volume Crated Weight EZ-3 21" (533) 13.5" (343) 22" (559) 9.5" (241) " (495) 31.5" (800) 28.5" (724) 10.1 cu. ft cu. m. 150 lbs. 68 kg. EZ " (689) 13.5" (1067) 22" (559) 15.5" (394) " (508) 34" (864) 38" (965) 15.1 cu. ft cu. m. 175 lbs kg. * Add 4 to height if 4 adjustable legs are used ** Pan Capacity is the number of 1, 2.5, or 4 high standard pans (12 wide x 20 deep) that the steamer will hold IMPORTANT: UNIT MUST BE LEVEL FOR PROPER OPERATION. WARRANTY WILL BE VOIDED FOR IMPROPER INSTALLATION. UTILITY INFORMATION MISCELLANEOUS Total Connected Amps Max. Amps per Line EZ-3 EZ-5 1-Phase 3-Phase 1-Phase 3-Phase - Check local codes for fire and sanitary regulations. 208V 60Hz V 50-60HZ V 60Hz /220V 50Hz /240V 50Hz V 60Hz Electric: EZ-3 - Total kw: 8; EZ-5 - Total kw: 11 - One fuse electrical connection is required to the terminal block of the steamer. All units are shipped per customer order, three or single phase. (A kit is available for field conversion to three phase or single phase.) The fused connection must be wired for the required voltage and maximum amperage as listed in the above chart. NOTICE: Southbend has a policy of continuous product research and improvement. We reserve the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment. - SS-6 Stand - SS-36 Stand - SS-44 Stand OPTIONS AND ACCESSORIES - Pan guides for stands - Table mount stand - 208V or 240V - 220V 50/60Hz, 3-phase - 480V 60Hz, 3-phase Form EZ INTENDED FOR COMMERCIAL USE ONLY. NOT FOR HOUSEHOLD USE Old Honeycutt Rd., Fuquay-Varina, NC

29 C Results Reporting Sheets Manufacturer: Southbend, A Middleby Company Model: Simple Steam, model EZ-3 Date: September 1999 Section 11.1 Test Steam Cooker ASTM F 1216 Classification (check one for each classification) Type I - Zero to 2.9 psig compartment pressure Type II - Three to 9.9 psig compartment pressure Type III - Ten to 15 psig compartment pressure Size One Compartment, 3 full-size pan capacity Size One Compartment, 4 full-size pan capacity Size One Compartment, 5 full-size pan capacity Size One Compartment, 6 full-size pan capacity Size One Compartment, 6 full-size pan capacity Size Two Compartment, 8 full-size pan capacity Size Two Compartment, 10 full-size pan capacity Size Two Compartment, 12 full-size pan capacity Size Two Compartment, 16 full-size pan capacity Size Three Compartment, 12 full-size pan capacity Size Three Compartment, 15 full-size pan capacity Size Three Compartment, 18 full-size pan capacity Size Three Compartment, 24 full-size pan capacity Style A - Counter mounted Style B - Floor mounted on an open stand Style C - Floor mounted on a cabinet base Style D - Wall Mounted Class A - Direct connection to potable external steam source Class B - Self-contained steam coil steam generator Class C - Self-contained gas fired steam generator Class D - Self-contained electric steam generator C-1

30 Results Reporting Sheets Description of operational characteristics: The ON/OFF lever is placed in the ON position, and two and a half gallons of water is manually poured into the trough above the door and the bottom of the cooking compartment. The heating element fires up when the door is closed. Water is manually drained at the end of the day or after a cooking event. Section 11.2 Apparatus The steamer was installed on a metal table under a 4-foot-deep canopy hood that was 6 feet 6 inches above the floor. The hood operated at a nominal exhaust rate of 150 cfm per linear foot of hood. There was at least 6 inches of clearance between the vertical plane of the steamer and the edge of the hood. The steamer was instrumented with an electric transducer to measure power and energy; a voltage regulator was used to maintain within 5 percent range of 208 V for all tests. A computerized data acquisition system recorded test information at 5-seconds intervals. All test apparatus were installed in accordance with Section 9 of the ASTM test method. Section 11.4 Energy Input Rate Test Voltage 208 ± 5.2 V Measured 8.02 kw Rated 8.3 kw Percent Difference between Measured and Rated 3.4 % Section 11.5 Boiler Preheat Energy Consumption and Duration Test Voltage 208 ± 5.2 V Energy Consumption 1.8 kwh Duration 8.7 min Section 11.6 Boiler Idle Energy Rate Test Voltage Idle Energy Rate 208 ± 5.2 V 0.92 kw C-2

31 Results Reporting Sheets Section 11.7 Ice Pan Cooking Time, Energy Efficiency, Energy Rate, Production Capacity, and Water Consumption Rate Full Load: Test Voltage 208 ± 5.2 V Cooking Time 20.3 min Cooking Energy Efficiency 89.5 ± 1.9 % Cooking Energy Rate 7.3 ± 0.1 kw Production Capacity 71.0 ± 1.7 lb/h Water Consumption Rate <2.5 gal/h Light Load: Test Voltage 208 ± 5.2 V Cooking Time 8.3 min Cooking Energy Efficiency 85.9 ± 2.7 % Cooking Energy Rate 6.2 ± 0.1 kw Production Rate 57.9 ± 2.2 lb/h Water Consumption Rate <2.5 gal/h Section 11.8 Frozen Green Peas Cooking Time, Energy Efficiency, Energy Rate, Production Capacity, and Water Consumption Rate Full Load: Test Voltage 208 ± 5.2 V Cooking Time 21.4 min Cooking Energy Efficiency 86.7 ± 0.9 % Cooking Energy Rate 6.1 ± 0.4 kw Production Capacity 67.2 ± 4.4 lb/h Water Consumption Rate <2.5 gal/h C-3

32 Results Reporting Sheets Light Load: Test Voltage 208 ± 5.2 V Cooking Time 11.8 min Cooking Energy Efficiency 74.5 ± 1.4 % Cooking Energy Rate 4.2 ± 0 kw Production Rate 40.8 ± 0.5 lb/h Water Consumption Rate <2.5 gal/h Section 11.9 Whole Red Potatoes Cooking Time, Energy Efficiency, Energy Rate, Production Capacity, and Water Consumption Rate Full Load: Test Voltage 208 ± 5.2 V Cooking Time 23.5 min Cooking Energy Efficiency 69.0 % Cooking Energy Rate 2.9 kw Production Capacity 61.4 lb/h Water Consumption Rate <2.5 gal/h Light Load: Test Voltage 208 ± 5.2 V Cooking Time 21.6 min Cooking Energy Efficiency 41.5 ± 3.1 % Cooking Energy Rate 1.8 ± 0.1 kw Production Rate 22.3 ± 0.6 lb/h Water Consumption Rate <2.5 gal/h C-4

33 D Cooking Energy Efficiency Data Table D-1. Preheat and Idle Data Measured Values Replication 1 Replication 2 Replication 3 Preheat Time (min) Preheat Energy (kwh) Idle Time (min) Idle Energy (kwh) Calculated Values Preheat Energy Rate (kw) Idle Energy Rate (kw) Idle Factor (%) D-1

34 Cooking Energy Efficiency Data Table D-2. Full-Load Ice Pan Data Measured Values Replication 1 Replication 2 Replication 3 Number of Pan(s) Cook Time (min) Initial Temperature of Ice Final Temperature of Ice ( F) Weight of Stainless-Steel Pans (lb) Weight of Ice (lb) Condensate Temperature ( F) n/a n/a n/a Water Consumption (gal/h) n/a n/a n/a Calculated Values Cooking Energy (kwh) Energy Consumed by Ice (Btu) Energy Consumed by Pans (Btu) Energy of Boiler Re-init (Btu) Energy Consumed by the Steamer (Btu) Cooking Energy Rate (kw) Productivity (lb/h) Energy Efficiency (%) D-2

35 Cooking Energy Efficiency Data Table D-3. Light-Load Ice Pan Data Measured Values Replication 1 Replication 2 Replication 3 Number of Pan(s) Cook Time (min) Initial Temperature of Ice Final Temperature of Ice ( F) Weight of Stainless-Steel Pans (lb) Weight of Ice (lb) Condensate Temperature ( F) n/a n/a n/a Water Consumption (gal/h) n/a n/a n/a Calculated Values Cooking Energy (kwh) Energy Consumed by Ice (Btu) Energy Consumed by Pans (Btu) Energy of Boiler Re-init (Btu) Energy Consumed by the Steamer (Btu) Cooking Energy Rate (kw) Productivity (lb/h) Energy Efficiency (%) D-3

36 Cooking Energy Efficiency Data Table D-4. Full-Load Peas Data Measured Values Replication 1 Replication 2 Replication 3 Number of Pan(s) Cook Time (min) Initial Water Temperature ( F) Final Water Temperature ( F) Frozen Food Temperature ( F) Weight of Empty Calorimeter (lb) Weight of Full Calorimeter (lb) Weight of Calorimeter Water (lb) Weight of Cooked Food (lb) Weight of Frozen Food (lb) Weight of Stainless-Steel Pans (lb) Moisture Content (%) Condensate Temperature ( F) n/a n/a n/a Water Consumption (gal/h) n/a n/a n/a Calculated Values Moisture Weight in Green Peas(lb) Final Food Temperature ( F) Cooking Energy (kwh) Energy Consumed by Green Peas (Btu) Energy Consumed by Pans (Btu) Energy of Boiler Re-init (Btu) Energy Consumed by the Steamer (Btu) Cooking Energy Rate (kw) Productivity (lb/h) Energy Efficiency (%) D-4

37 Cooking Energy Efficiency Data Table D-5. Light-Load Peas Data Measured Values Replication 1 Replication 2 Replication 3 Number of Pan(s) Cook Time (min) Initial Water Temperature ( F) Final Water Temperature ( F) Frozen Food Temperature ( F) Weight of Empty Calorimeter (lb) Weight of Full Calorimeter (lb) Weight of Calorimeter Water (lb) Weight of Cooked Food (lb) Weight of Frozen Food (lb) Weight of Stainless-Steel Pans (lb) Moisture Content (%) Condensate Temperature ( F) n/a n/a n/a Water Consumption (gal/h) n/a n/a n/a Calculated Values Moisture Weight in Green Peas(lb) Final Food Temperature ( F) Cooking Energy (kwh) Energy Consumed by Green Peas (Btu) Energy Consumed by Pans (Btu) Energy of Boiler Re-init (Btu) Energy Consumed by the Steamer (Btu) Cooking Energy Rate (kw) Productivity (lb/h) Energy Efficiency (%) D-5

38 Cooking Energy Efficiency Data Table D-6. Full-Load Potatoes Data Measured Values Replication 1 Replication 2 Number of Pan(s) 3 3 Cook Time (min) Temperature of Uncooked Potatoes ( F) Temperature of Cooked Potatoes ( F) Weight of Stainless-Steel Pans (lb) Weight of Potatoes (lb) Total Potato Count Moisture Content (%) Condensate Temperature ( F) n/a n/a Water Consumption (gal/h) n/a n/a Calculated Values Moisture Weight in Potatoes (lb) Average Weight of Each Potatoes (lb) Cooking Energy (kwh) Energy Consumed by Potatoes (Btu) Energy Consumed by Pans (Btu) Energy of Boiler Re-init (Btu) 0 0 Energy Consumed by the Steamer (Btu) Cooking Energy Rate (kw) Productivity (lb/h) Energy Efficiency (%) D-6

39 Cooking Energy Efficiency Data Table D-7. Light-Load Potatoes Data Measured Values Replication 1 Replication 2 Replication 3 Number of Pan(s) Cook Time (min) Temperature of Uncooked Potatoes ( F) Temperature of Cooked Potatoes ( F) Weight of Stainless-Steel Pans (lb) Weight of Potatoes (lb) Total Potato Count Moisture Content (%) Condensate Temperature ( F) n/a n/a n/a Water Consumption (gal/h) n/a n/a n/a Calculated Values Moisture Weight in Potatoes (lb) Average Weight of Each Potatoes (lb) Cooking Energy (kwh) Energy Consumed by Potatoes (Btu) Energy Consumed by Pans (Btu) Energy of Boiler Re-init (Btu) Energy Consumed by the Steamer (Btu) Cooking Energy Rate (kw) Productivity (lb/h) Energy Efficiency (%) D-7

2007 GFEN Blue Flame Product of the Year Award Form

2007 GFEN Blue Flame Product of the Year Award Form 2007 GFEN Blue Flame Product of the Year Award Form Please e-mail this form to GFEN with supporting documentation: photo(s), specification sheets, brochures, etc. to GFEN. Entries must be submitted no

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Electric Conveyor Toaster APW Wyott ECO4000-500E Test Report FSTC Report # 501311117 Application of ASTM Standard Test Method F2380 April 2012 Prepared by: Denis Livchak

More information

Food Service Technology Center

Food Service Technology Center Food Service Technology Center Electric Conveyor Toaster APW Wyott ECO4000-350E Test Report FSTC Report # 501311118 Application of ASTM Standard Test Method F2380 April 2012 Prepared by: Denis Livchak

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

Middleby Marshall, Model PS570 Conveyor Oven Performance Test

Middleby Marshall, Model PS570 Conveyor Oven Performance Test Middleby Marshall, Model PS570 Conveyor Oven Performance Test Application of ASTM Standard Test Method F 1817-97 CKVL Report 0011107 April 2003 Prepared by: Rich Swierczyna Paul Sobiski Architectural Energy

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

9 Steam Kettles. Introduction. Cooking Process

9 Steam Kettles. Introduction. Cooking Process 9 Steam Kettles Introduction Steam kettles are an improved, self-contained version of the large stockpot used for range top cooking. And they are put to many of the same tasks. Steam kettles are often

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

On-Site Energy Monitoring of a Two-Group Espresso Machine Special Report

On-Site Energy Monitoring of a Two-Group Espresso Machine Special Report On-Site Energy Monitoring of a Two-Group Espresso Machine Special Report FSTC Report 5011.00.91 Food Service Technology Center Manager: Don Fisher Final Report December 2000 Prepared by: Richard Young

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

8 Steamers. Introduction

8 Steamers. Introduction 8 Steamers Introduction Commercial steamers provide an easy, fast way to prepare large quantities of food. Steaming offers good nutrient retention, short cook times, and ease of preparation; little attention

More information

Traulsen Two-Door Reach-In Refrigerator Performance Test

Traulsen Two-Door Reach-In Refrigerator Performance Test Traulsen Two-Door Reach-In Refrigerator Performance Test In accordance with ASHRAE 117-1992R Method of Testing Closed Refrigerators FSTC Report 5011.99.73 Food Service Technology Center Final Report, December

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

Recover Heat from Boiler Blowdown Water

Recover Heat from Boiler Blowdown Water Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC and its contractor, Southern California Gas

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks

More information

VAV Laboratory Room Airflow The Lowdown on Turndown

VAV Laboratory Room Airflow The Lowdown on Turndown Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx

More information

Model: Model: Description: Voltage: Amps: 15.3. Ice Type: Unit Weight:

Model: Model: Description: Voltage: Amps: 15.3. Ice Type: Unit Weight: Model MIM452 Project Name: Location: Item: Qty: Modular Ice Maker FEATURE LIST MIM452 Description: Modular Ice Maker Voltage: 120V/60Hz/1Ph, 220V/50Hz/1Ph Amps: 15.3 Model MIM452 (Shown on bin, model MIB400,

More information

Energy Efficiency Business Rebates Natural Gas Catalog

Energy Efficiency Business Rebates Natural Gas Catalog Energy Efficiency Business Rebates Natural Gas Catalog RECENT NATURAL GAS CHANGES A new table has been added to the process boiler section. Please review to ensure your product meets all efficiency requirements.

More information

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL ANI-64S-xRU Single Section Wall Cabinet INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com A-Neutronics.com SAFETY

More information

French Door Refrigerator E23BC78IPS professional series

French Door Refrigerator E23BC78IPS professional series French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units 2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units ANSI/AHRI Standard 540 (formerly ARI Standard 540) IMPORTANT SAFETY RECOMMENDATIONS ARI does not

More information

Beverage-Air Refrigerator Performance Testing

Beverage-Air Refrigerator Performance Testing Beverage-Air Refrigerator Performance Testing Application of ASHRAE 117-2002 FSTC Report # 5011.03.01 Final Report, January 2003 Prepared by: Fred Wong David Zabrowski David Cowen Fisher-Nickel, Inc. Contributor:

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

ThermoSorb Desiccant Dryers

ThermoSorb Desiccant Dryers ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression

More information

Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting

Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting FSTC Report 501310087 Food Service Technology Center September 2011 Prepared by: Angelo Karas David Cowen Don

More information

Ceiling Mount Air Handler Manual

Ceiling Mount Air Handler Manual www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Improving Rack Cooling Performance Using Airflow Management Blanking Panels Improving Rack Cooling Performance Using Airflow Management Blanking Panels By Neil Rasmussen White Paper #44 Revision 3 Executive Summary Unused vertical space in open frame racks and rack enclosures

More information

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined

More information

steam centre of excellence Steam Boiler System Optimization

steam centre of excellence Steam Boiler System Optimization Steam Boiler System Optimization Introduction Gas Cost Metering Fluids Fuel, Water, Steam Steam Costs Boiler House Stack Losses Boiler Waterside Surfaces Blowdown Current Natural Gas Cost Projected Cost

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

FOXAIR 60/50 ALL MODELS

FOXAIR 60/50 ALL MODELS FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,

More information

Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers. FINAL REPORT June 2005. Angelo Karas Victor Kong Don Fisher

Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers. FINAL REPORT June 2005. Angelo Karas Victor Kong Don Fisher Evaluating the Water Savings Potential of Commercial Connectionless Food Steamers FINAL REPORT June 2005 Prepared by: Angelo Karas Victor Kong Don Fisher Fisher-Nickel, inc. Food Service Technology Center

More information

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

DOUBLE SEAT BRONZE BODY HIGH CAPACITY PS593DB HEAVY DUTY BRONZE GLOBE CONTROL VALVES DB DOUBLE SEAT BRONZE BODY HIGH CAPACITY 1, 1-1/4, 1-1/2, and 2 Union Ends ANSI Class 250 Body Rating ANSI Class II Close off Bronze or Stainless Steel Trim

More information

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

VACUUM REFRIGERATION SYSTEMS

VACUUM REFRIGERATION SYSTEMS VACUUM REFRIGERATION SYSTEMS CHILL VACTOR The Croll-Reynolds CHILL-VACTOR is a chiller that uses a vapor flashing process. Water has a pressure-temperature relationship which is its boiling point. If its

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Some Criteria for Choosing a Steam Boiler for a Microbrewery

Some Criteria for Choosing a Steam Boiler for a Microbrewery Some Criteria for Choosing a Steam Boiler for a Microbrewery Jack Coe Rite Engineering and Manufacturing Corporation Breweries rely on steam heating for a number of functions, primarily to heat the brew

More information

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank

Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank Overview of Heat Recovery Boiler Systems and Operating Costs Factors Effecting Blowdown Blowdown Heat Recovery The Energy Tank Unbiased, Third-Party, Water & Energy Management Consulting Firm: - Not affiliated

More information

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Improving Rack Cooling Performance Using Airflow Management Blanking Panels Improving Rack Cooling Performance Using Airflow Management Blanking Panels White Paper 44 Revision 4 by Neil Rasmussen > Executive summary Unused vertical space in open frame racks and rack enclosures

More information

Approval Standard for Plastic Suspended Ceiling Panels

Approval Standard for Plastic Suspended Ceiling Panels Approval Standard for Plastic Suspended Ceiling Panels Class Number 4651 February 1978 2002 FM Approvals LLC. All rights reserved. Foreword The FM Approvals certification mark is intended to verify that

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Case Studies in Restaurant Water Heating

Case Studies in Restaurant Water Heating Case Studies in Restaurant Water Heating Donald Fisher, Fisher-Nickel, Inc. William Pietrucha, Pacific Gas and Electric Company ABSTRACT This paper presents an overview of hot water use and the associated

More information

Access Server Rack Cabinet Compatibility Guide

Access Server Rack Cabinet Compatibility Guide Access Server Rack Cabinet Compatibility Guide A Guide to the Selection and Evaluation of Access Server Rack Cabinets for Compatibility and Use with Third Party Server Chassis Kalkenstraat 91-93 B-8800

More information

Commercial Gas Water Heaters

Commercial Gas Water Heaters CYCLONE Mxi MODULATING MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide years of dependable

More information

Arapahoe County Residential Water Heater Installation and Inspection Guide

Arapahoe County Residential Water Heater Installation and Inspection Guide Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however

More information

Climate chamber with illumination

Climate chamber with illumination KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

User Manual THR840DUK Digital Thermostat

User Manual THR840DUK Digital Thermostat User Manual THR840DUK Digital Thermostat 50051982-001 Rev. A WARNING: This product must be correctly installed and configured to work properly (see pages 12-24). If you are not experienced in wiring electrical

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

MINNESOTA STATE COLLEGES AND UNIVERSITIES ST. CLOUD STATE UNIVERSITY

MINNESOTA STATE COLLEGES AND UNIVERSITIES ST. CLOUD STATE UNIVERSITY F.Y.: 2014 Cost Center: Obj. Code: Amount: Vendor #: Bid #: 141304 MINNESOTA STATE COLLEGES AND UNIVERSITIES ST. CLOUD STATE UNIVERSITY Contact Person: Lisa Sparks, Director of Purchasing St. Cloud State

More information

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in

More information

G234X-55 Conventional Gas Boiler

G234X-55 Conventional Gas Boiler Engineering Submittal Sheet Boiler Overview C US Engineering Specifications There shall be provided and installed a quantity of Buderus G234X-55 fl oor standing hot water boiler(s), suitable with natural

More information

Session 2: Hot Water Supply

Session 2: Hot Water Supply MEBS6000 Utility Services http://www.hku.hk/mech/msc-courses/mebs6000/index.html Session 2: Hot Water Supply Dr. Benjamin P.L. Ho Department of Mechanical Engineering The University of Hong Kong E-mail:

More information

F9MXE. Product Specifications

F9MXE. Product Specifications 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports

More information

WARMER or COOKER/WARMER

WARMER or COOKER/WARMER WARMER or COOKER/WARMER Use & Care Manual FW-S500 WARMER 3138365 Conforms to: UL STD: 197 3138365 Conforms to: NSF STD.4 FW-S600 COOKER / WARMER Model Description Size Voltage Hz Wattage FW-S500 Electric

More information

Scotch-Weld PUR Easy 250 Adhesive Applicator

Scotch-Weld PUR Easy 250 Adhesive Applicator Scotch-Weld September, 2014 Product Description PUR Easy 250 Applicator is a self contained pneumatic applicator designed to dispense 1/10 th gallon(300ml) cartridges of 3M PUR adhesives. PURs are a family

More information

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This

More information

HOSHIZAKI AMERICA, INC.

HOSHIZAKI AMERICA, INC. Item #40096 10/27/2014 1 HOSHIZAKI AMERICA, INC. Hoshizaki America has built a legacy of quality design, reliability and customer commitment. In our Commercial Series refrigeration line, you ll see solutions

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana Architectural Testing TEST REPORT Report No.: D0162.02-201-44 Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana PRODUCT TYPE: Pressure Equalized Rainscreen SERIES/MODEL: 4 mm Composite

More information

GenStore Archive Cabinet

GenStore Archive Cabinet GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4

More information

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications

More information

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480 Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions

More information

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com

ARMSTRONG AIR HEAT PUMPS www.armstrongair.com INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7

More information

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH Centauri Condensing Fire Tube Water Boiler 399 to 1000 MBH Pre-mix surface burner with up to a 7-to-1 turndown NOx levels as low a 5 ppm at full rate Operates on 4" gas pressure shown with optional gauges

More information

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers Peerless Boilers Series GM Residential/Commercial Gas Boilers The Series GM cast iron, hot water boiler is ideal for use in large residences or commercial applications. This gas-fired, atmospheric boiler

More information

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Boiler & Pressure Vessel Inspection discrepancies and failures

Boiler & Pressure Vessel Inspection discrepancies and failures Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:

More information

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Thru-the-wall AIR CONDITIONERS COOL ONLY HEAT PUMPS ELECTRIC HEAT

Thru-the-wall AIR CONDITIONERS COOL ONLY HEAT PUMPS ELECTRIC HEAT Thru-the-wall AIR CONDITIONERS 2009 COOL ONLY HEAT PUMPS ELECTRIC HEAT THRU-THE-WALL 27 sleeve Friedrich thru-the-wall air conditioners are ideal for new construction, retrofits and remodels 8,000 to 15,800

More information

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book USERS GUIDE LOGIC Heat 12, 15, 18, 24, 30 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

Performance Rating of Room Fan- Coils

Performance Rating of Room Fan- Coils ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS

More information

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS

FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS FOOD ESTABLISHMENT GUIDE FOR DESIGN, INSTALLATION, AND CONSTRUCTION RECOMMENDATIONS PART 9 - HOT WATER SUPPLY REQUIREMENTS The hot water supply shall be sufficient to satisfy the continuous and peak hot

More information

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,

More information

PLP - TERMS AND CONDITIONS

PLP - TERMS AND CONDITIONS PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia

More information

Engineers Edge, LLC PDH & Professional Training

Engineers Edge, LLC PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown Boiler Blowdown Even with the best pretreatment programs, boiler feedwater often contains some degree of impurities, such as suspended and dissolved solids. The impurities can remain and accumulate inside

More information

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM

More information

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers For Industrial Heating Equipment and Boilers Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC

More information

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

HOW TO SELECT A LOW VOLUME (L.V ) BOILER HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement

More information

Dehumidifier Users manual. For Models: DH45S DH65S

Dehumidifier Users manual. For Models: DH45S DH65S Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor