SILENT KNIGHT 5000 Series
|
|
|
- Virginia Gibson
- 10 years ago
- Views:
Transcription
1 SILENT KNIGHT 5000 Series Entry System Installation and Operation Manual Part Number D, 01/03
2 Content Section 1 Overview User Features What s In the Box About this Manual Terminology Section 2 Telephone Requirements Before Connecting The Control Panel INDUSTRY CANADA WARNINGS AVIS D INDUSTRIE CANADA Section 3 Installation Instructions Model 5083/84 Parts Keypad and LCD Main Control Board Main Control Board Components Description Main Power Switch Programming Dip Switch Battery Connector AC Power Input Terminals Door and Auxiliary Relay Terminals The Door and Auxiliary Reset Terminals SBUS Terminals Phone line Terminals Board Components Description Mounting Instructions Flush Mount Surface Mount Wiring Instructions Power Requirements Installing the AC Transformer Transient Protection For 5083/5084 Panels How to Verify Earth Ground Battery Connections SBUS Wiring Calculating Wiring distance for SBUS modules Wiring and Configuring Master and Satellite Units Wiring a Satellite to the Master unit Connecting Multiple Satellites to the Master Unit i
3 Series 5000 Entry System Installation/Operation Manual Configuring Master and Satellite Unit IDs Installing DC Doorstrike Installing an AC Doorstrike Doorstrike Reset Switch Installing Phone Lines Using Ground Start Installing a Mail Carrier Lock panel Installing a Sonalert/Piezo to the Alarm Output Model 5076 Heater Kit To Install the 5076 Heater Section 4 Operation Modes Entering, Changing Options and Exiting Operating Modes To enter an operating mode: If The Access Code Is Not Known: To Change a Selection To Skip a Selection To Exit Any Operating Mode Operating Modes Operation Mode 0: System Options Operation Mode 1 User Information Add User Information Edit User Information Delete User Information Operating Mode 2 Time Set Operating Mode 3 Activate Door Relay Operating Mode 4 Activate Auxiliary Relay Operating Mode 5 Telephone Operating Mode 6 Memory Clear Quick Chart Section 5 Testing and Troubleshooting /5084 Field Test Test the Doorstrike Operation Test the Dialing Operation Satellite Field Test Test the Doorstrike Operation Test the Dialing Operation Troubleshooting To Avoid Problems Standby Electrical Voltages System Messages ii
4 Content Section 6 User Operation Visitor Operation Tenant Access Operation Auxiliary Door Access Operation Postal Access Operation Door Attendant Notification Operation Section 7 Programming information record System Options Record User Information Record iii
5 Series 5000 Entry System Installation/Operation Manual iv
6 Section 1 Overview The Silent Knight Models 5083 Handsfree and 5084 Handset make up a family of entry security systems which provide reliable entry control for large multi-tenant buildings. 1.1 User Features Only resident-side telephones will open doors Door-strike time lengths are programmable to fit the installation requirements Programmable user codes for keyless entry (4 to 6 digits) All tenant phone numbers remain confidential Optional automatic enable/disable times for auxiliary relay Optional touch-tone auxiliary relay activation from user phone Rotary or DTMF dialing 20-digit phone numbers Audio On or Off option when dialing 1,000 user capacity Ground start telephone systems Call length seconds User number length 1-8 digits Dial through PBX systems Door open time seconds Selectable system messages Modular design for multiple door access points
7 Series 5000 Entry System Installation/Operation Manual 1.2 What s In the Box Table 1-1 describes what you will find when you open the box of the 5083/5084 Entry System Control Panel. Table 1-1: What s in the Box Item P/N Where to Find Stainless steel cabinet with control inside 5083/5084 Section 3.4 Wall Mount Bracket Section 3.3 Keys (in small envelope) 1347 Battery 6912 Section Transformer 9220 Section Transient Protector 7890 Section N5401 Diode N/A Section Series 5000 Installation Manual About this Manual This manual explains the installation and operation procedures for the 5000 Series System. Section 2 describes telephone company requirements and other specifications that must be met before installing the system. Section 3 provides installation instructions. The Programming sequence and operating procedures are described in Section 4. Section 5 describe field test procedures and troubleshooting concerns. Section 6 describes user and visitor operation of the system Terminology In this manual the term User refers to any one that will be using the system such as a tenant or resident of the facility using the 5000 series entry system
8 Section 2 Telephone Requirements This section contains information about the telephone companies installation requirements and should be reviewed prior to system installation. 2.1 Before Connecting The Control Panel The following information must be provided before connecting this system to the phone lines if it is requested by the telephone company. Manufacturer Silent Knight Model Number 5083 & 5084 FCC Registration Ringer Equivalence Type of jack AC6USA MT-T 0.4B AC and 0.3 DC RJ11X This device may not be directly connected to coin telephone or party line service. Under certain circumstances the telephone company may temporarily discontinue service and/ or make changes in its facilities and services that may affect the operation of this device. However, the telephone company is required to give adequate notice in writing of such changes or interruptions. **Important Notice** Due to wide variations in telephone company exchange switching equipment, Silent Knight can no longer guarantee that the 5000 Series Apartment Entry System will function properly when used to decode the digit 6 from rotary (dial type) telephones. For those exchanges where rotary phones will not work, each apartment must have a Touch-Tone telephone
9 Series 5000 Entry System Installation/Operation Manual 2.2 INDUSTRY CANADA WARNINGS NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. NOTICE: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Number of all the devices does not exceed
10 Telephone Requirements AVIS D INDUSTRIE CANADA AVIS: L étiquette d Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n assure toutefois pas que le matériel fonctionnera à la satisfaction de l utilisateur. Avant d installer ce matériel, l utilisateur doit s assurer qu il est permis de le raccorder aux installations de l entreprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée de raccordement. L abonné ne doit pas oublier qu il est possible que la comformité aux conditions énoncées ci-dessus n empêche pas la dégradation du service dans certaines situations. Les réparations de matériel homologué doivent être coordonnées par un représentant désigné par le fournisseur. L entreprise de télécommunicationspeut demander à l utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l utilisateur ou à cause de mauvais fonctionnement. Pour sa propre protection, l utilisateur doit s assurer que tous les fils de mise à la terre de la source d énergie électrique, des lignes téléphoniques et des canalisations d eau métalliques, s il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement: L utilisateur ne doit pas tenter de faire ces raccordements luimême; il doit avoir recours à un service d inspection des installations électriques, ou à un électricien, selon le cas. AVIS: L indice d équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d une interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition quela somme d indices d équivalence de la sonnerie de tous les dispositifs n excède pas
11 Series 5000 Entry System Installation/Operation Manual
12 Section 3 Installation Instructions This section describes the different parts of the 5000 Series Entry System circuit board. 3.1 Model 5083/84 Parts Figure 3-1 and Figure 3-2 show the printed circuit boards of the 5083 and 5084 main module. These printed circuit boards contain the switches, LCD, keypad and terminals required to run the main control system Keypad and LCD The LCD is used for prompting the user and reflecting the numbers pressed on the keypad. When the user sees that the correct data is displayed, pushing the key will enter the data into memory. Figure Keypad Board Assembly
13 Series 5000 Entry System Installation/Operation Manual Main Control Board The main control board contains the circuitry for charging the standby battery, dialing and controlling a maximum of four Remote Satellite Units (5083/5084). Programming Dip Switch Main Power Switch Battery Connector AC Power Input Door/Aux Relays Door/Aux Reset SBUS Terminals Phone Line Terminals Figure (Hands Free) and (Handset) Board Assembly Main Control Board Components Description This section describes the components on the main control board as shown in Figure Main Power Switch The main power switch, in the On position applies power to the main control panel. In the Off position power is removed from the main control panel and all system options and user information is stored in Flash memory Programming Dip Switch The programming dip switch is used to configure the unit as a master unit or as a satellite unit. Each satellite unit requires a unique unit ID number. See also Section Battery Connector The battery connector is used to connect the systems backup battery to the control panel. See Section for backup battery installation instructions
14 Installation Instructions AC Power Input Terminals The AC power input terminal are used to connect the AC transformer to the control panel. See Section for AC transformer wiring instructions Door and Auxiliary Relay Terminals The door and auxiliary relay terminal can be used to connect a AC or DC door strike which is control by the control panel. The maximum allowable draw from a doorstrike is 250 1A The Door and Auxiliary Reset Terminals The Door and Auxiliary Reset Terminals are used to connect a door reset switch to the control panel. See Section for more information SBUS Terminals The SBUS terminals are used to connect satellite units to the master control unit in a system. See Section for more information Phone line Terminals The phone line terminals are used to connect the system phone line to the control panel. See Section for more information
15 Series 5000 Entry System Installation/Operation Manual Board Components Description Table 3-1: Terminal Descriptions Terminal No. Name Description 1 AC 1 2 AC 2 AC power input connections. 3 EARTH 4 COM Door Relay connections. 5 NO 6 COM Auxiliary relay connections. 7 NO 8 DOOR Door reset. 9 AUX Aux reset Positive ma used for alarm output. 11 GND 12 + SBUS for satellite connections. 13 A 14 B 15 RING Telephone line connections. TIP 3.2 Mounting Instructions This section contains information necessary to properly mount the 5083, and 5084 panels. Avoid installing the 5083 and 5084 in a high noise environment such as a noisy lobby or outside where there is a large amount of traffic or airplane noise. Do Not mount the 5000 series units in locations subject to high temperatures, such as over a lobby heater. Be sure to seal any openings into the entry system back box that connect to the interior walls. This is to prevent water damage that could occur if warm moist air entered the back box and condensed on the board surfaces. The operating temperature range must be between 0 C and +50 C (32 F and +120 F) or humidity outside the range of 10%-85% at 86 F (30 C) non-condensing. With the addition of the model 5076 Heater Kit, the operating temperature range can be extended to between -28 C and +50 C (-20 F and +120 F). (See Section ) Note: The 5000 Entry System is designed for use in a sheltered outdoor environment and the system circuitry will operate normally in the temperature ranges listed
16 Installation Instructions 3.3 Flush Mount Note: In order to flush mount the unit, the wall must be at least 3-1/2 inches thick. 1. Make a hole in the wall near a stud at the desired location. This hole should be 11-1/4 inches wide and 11 inches high. 2. If the studs are farther apart than the width required, attach some shims to the stud inside the wall so that the shims and the first stud are the right width. 3. Screw the back box to the stud on one side and the shims on the other. Three holes are provided in each side flange of the back box (see Figure 3-3). Figure 3-3 Flush Mounting
17 Series 5000 Entry System Installation/Operation Manual 3.4 Surface Mount 1. Make a cardboard template to locate the hole positions. When mounting on interior walls, use appropriate screws and anchors in plaster. When mounting on concrete, especially where moisture is present, attach a piece of 3/4 inch plywood to the concrete surface. 2. Slide the unit into the wall adapter. 3. Mount to the wall through the 4 holes in the back of the box (see Figure 3-4). Figure 3-4 Surface Mount
18 Installation Instructions 3.5 Wiring Instructions The following section contains information necessary to properly wire the Model 5000 Entry System Power Requirements The 5083 and 5084 main units are powered from a UL listed Class II, 16.5 VAC 40 VA transformer that plugs directly into a 120 VAC 60Hz wall outlet. The transformer provides power for the 5083 and 5084 main units and charging current for the 12 VDC backup battery. In the event of a power outage, the 12 VDC, 1.2 AH battery (shipped with the unit) will provide enough current to run the system for a minimum of 2 hours. The actual time will depend on how much the system is used. All programmed data will be stored in Flash memory if AC power is lost and the backup battery becomes depleted Installing the AC Transformer Wire the transformer (Model 9220) to terminals 1 and 2 on the 5083 and 5084 printed circuit board. Use 16-gauge or larger (14, 12, etc.) shielded wire. Ground the shield to terminal #3 on the 5083 or 5084 and to the center screw terminal on the transformer as shown in Figure 3-5. Also verify that the outlet is a non-switching circuit. Figure 3-5 AC Transformer Wiring Diagram
19 Series 5000 Entry System Installation/Operation Manual Transient Protection For 5083/5084 Panels The AC lines are the most common source of transient or lighting damage in electronics. The transient protection on the 5083 and 5084 control panel will only work if the panel is correctly earth grounded. Warning: To avoid risk of electrical shock, you may wish to have a licensed electrician ground the electrical outlet How to Verify Earth Ground To verify earth ground at the AC outlet the 5083/5084 control panel is powered from, use the following steps: 1. Measure the AC voltage between the center ground post and each side of the outlet (see A & B in Figure 3-6). You should read approximately 120 VAC at measurement point B and nominal VAC at measurement point A. Figure 3-6 Outlet Voltage Measurement Points 2. Measure the voltage between the two slotted holes. It should be equal to the voltage reading at measurement point B. (See Figure 3-6.) If these voltages are not equal, the outlet does not have a proper earth ground. 3. Ground the outlet by running a wire (18 gauge or higher) to a good earth ground. The wire should be of equal or greater diameter to the wires used to feed the outlet. It may be necessary to have a licensed electrician ground the outlet
20 3.5.5 Battery Connections Installation Instructions The transformer provides power for the 5083 and 5084 main units and charging current for the 12 VDC backup battery. In the event of a power outage, the 12 VDC, 1.2 AH battery (shipped with the unit) will provide enough current to run the system for a minimum of 2 hours. The actual time will depend on how much the system is used. All programmed data will be stored in Flash memory if AC power is lost and the backup battery becomes depleted. To connect the backup battery (Model 6912). 1. Connect the black battery cable to the minus (-) terminal of the battery. (See Figure 3-7 for battery cable location.) 2. Connect the red battery cable to the positive (+) terminal of the battery. Battery Wiring Harness Provided Figure 3-7 Backup Battery Connection
21 Series 5000 Entry System Installation/Operation Manual SBUS Wiring This section contains information on calculating SBUS wire distances and the types of wiring configurations Calculating Wiring distance for SBUS modules The following instructions will guide you in determining the type of wire and the maximum wiring distance that can be used with control panel SBUS accessory modules. To calculate the wire gauge that must be used to connect SBUS modules to the control panel, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. The individual worst case values are shown in the table below. Note: Total worst case current draw on a single SBUS cannot exceed 1 amp. Model Number amps amps Worst Case Current Draw After calculating the total worst case current draw, Table 3-2 specifies the maximum distance the modules can be located from the panel on a single wire run. The table insures 2.0 volts of line drop maximum. In general, the wire length is limited by resistance, but for heavier wire gauges, capacitance is the limiting factor
22 Installation Instructions (The formula used to generate this chart is shown in the note below). Table 3-2: Wire Distances Per Wire Gauge Wiring Distance: SBUS Modules to Panel Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge ft ft ft ft ft. 781 ft ft ft ft. 521 ft. 829 ft ft ft. 391 ft. 622 ft. 984 ft ft. 313 ft. 498 ft. 787 ft ft. 260 ft. 415 ft. 656 ft ft. 223 ft. 355 ft. 562 ft ft. 195 ft. 311 ft. 492 ft ft. 174 ft. 276 ft. 437 ft (Max) 62 ft. 156 ft. 248 ft. 394 ft. Note: The following formulas were used to generate the wire distance chart: Maximum Resistance (Ohms) = 2.0 Volts Total Worst Case Current Draw (amps) Maximum Wire Length (Feet) = Maximum Resistance (Ohms) (6000 feet maximum) Rpu where: Rpu = Ohms per 1000 feet for various Wire Gauges (see table below) * 500 Table 3-3: Typical Wire Resistance Per 1000 ft. Wire Gauge Ohms per 1000 feet (Rpu)
23 Series 5000 Entry System Installation/Operation Manual Wiring Distance calculation example: Suppose a system is configured as follows: as the Master unit satellite units The total worst case current is calculated as follows: Two 5083 satellite units = 2 x.200 amps =.400 amps Total Worst Case Current Draw =.400 amps Using this value, and referring to the Wiring Distance table, it can be found that the available options are: 154 feet maximum using 22 Gauge wire 391 feet maximum using 18 Gauge wire 622 feet maximum using 16 Gauge wire 984 feet maximum using 14 Gauge wire
24 Installation Instructions Wiring and Configuring Master and Satellite Units This Section describes how to properly wire and configure satellite units to the master unit in an installation. In installations where users have access to more than one entry point a satellite units can be installed. Each 5083 or 5084 can be configured as a master or a satellite unit (see Section ). Only one unit in the system can be the master unit Wiring a Satellite to the Master unit Connect a satellite to the master unit as shown in Figure 3-8. Figure 3-8 Connecting a Satellite to the Master Unit Note: Satellite units Do Not require a separate transformer. Satellite power is provided by terminals 11 & 12 of the master unit. Do Not connect backup batteries to the satellite unites
25 Series 5000 Entry System Installation/Operation Manual Connecting Multiple Satellites to the Master Unit In installations requiring more than one satellite unit in the system, connect multiple satellites as shown in Figure 3-9. Master Unit Satellite 1 Satellite 3 Satellite 2 Satellite 4 Figure 3-9 Multiple Satellites Connected to Master Unit Note: Phone lines must be run to each satellite unit. The phone lines can be run in parallel from the master unit
26 Installation Instructions Configuring Master and Satellite Unit IDs For the system to communicate properly between the master unit and the satellite units, the master unit must be be identified and each satellite unit must have its own ID number. Refer to Table 3-4 to properly configure the dip switches on each unit in your installation. Table 3-4: Dip Switch Configurations Unit Name Dip Switch Number Master ON ON For Handsfree Any OFF For Handset Position Any Position Satellite 1 OFF ON OFF For Handsfree For Handset ON ON Satellite 2 OFF ON OFF For Handsfree For Handset ON OFF Satellite 3 OFF ON OFF For Handsfree For Handset OFF ON Satellite 4 OFF ON OFF For Handsfree For Handset OFF OFF
27 Series 5000 Entry System Installation/Operation Manual Installing DC Doorstrike 1. Install the electric doorstrike in the door frame according to the manufacturer s specifications. Figure 3-10 DC Doorstrike Wiring Diagram 2. For a DC power doorstrike place a jumper wire between terminals 5 and 12 (see Figure 3-10). 3. Connect the doorstrike to terminals 4 and 11 (see Figure 3-10). Note: Only ONE doorstrike per system can be installed this way. Any additional doorstrikes must be AC-driven or powered by a separate power supply. 4. Install a reverse bias diode (1N5401 supplied with the 5083 and 5084 panels) across the DC doorstrike coil to suppress arcing and electrical noise. (See Figure 3-10.) Caution: The maximum allowable current to operate a DC doorstrike is 1A. Damage to the power supply and to the battery charging circuit will occur if this is exceeded
28 Installation Instructions Installing an AC Doorstrike 1. Install the electric doorstrike in the door frame according to the manufacturer s specifications. Figure 3-11 AC Doorstrike Wiring Diagram 2. Wire a transformer (24 VAC maximum) in series with the door strike opener, to terminals 4 and 5. (See Figure 3-11.) Note: Do Not use the transformer that powers the 5083 or 5084 control panel. All AC doorstrikes must be powered by a separate AC transformer. The maximum voltage rating of the door strikes contacts is 1A. Do Not install a reverse bias diode across the coil Doorstrike Reset Switch In installation sites requiring a magnetic contact to re-lock a door prior to the expiration of the programmed time ( DOOR TIME see section step 22) use the following steps. 1. Wire the contact to terminals 8 and 11. (See Figure 3-10 or Figure 3-11.) 2. The contact must be in the open state when the magnet is next to it
29 Series 5000 Entry System Installation/Operation Manual Installing Phone Lines The 5000 Series Entry System requires a RJ11X or RJ11W telephone jack to be installed by the phone company. Wire the phone lines to 5083 or 5084 control panel terminals 15 and 16. (See Figure 3-12.) Figure 3-12 Telephone Wiring Diagram Using Ground Start If the phone system at the installation site is a ground start system, the auxiliary relay must be programmed for Ground Start (See step 28 for instruction on Auxiliary relay programming). See Figure Figure 3-13 Ground Start Telephone Wiring Diagram
30 Installation Instructions Installing a Mail Carrier Lock panel. Note: The mail carrier lock is optional and is supplied by the Post Office. 1. Remove the Mail Carrier Lock hole plug. (See Figure 3-14.) Model 5084 Mail Carrier Lock Model 5083 Hole Plug Figure 3-14 Mail Carrier Lock Hole Plug Location 2. Install the lock on the 4 posts on the inside of the door. Use the the #8-32 nuts and lock washers (both supplied) to secure the mail carrier lock (see Figure 3-15). Figure 3-15 Inside view of 5083/5084 Control Panel
31 Series 5000 Entry System Installation/Operation Manual 3. Remove the red cap from the mail carrier lock button. (See Figure 3-15 for red cap location.) 4. Adjust the push-button switch so that the button is completely out when the mail carrier key is turned in the lock. Note: If the mail carrier lock is not used, do not remove the red cap from the mail carrier button Installing a Sonalert/Piezo to the Alarm Output In installation sites requiring an alarm output when the door access codes are tampered with, a sonalert/piezo (12 VDC, 100 ma maximum) can be installed. Follow these instructions to install a sonalert to the control panel. 1. Connect a sonalert across terminals 7 and 10. (See Figure 3-16.) Figure 3-16 Sonalert/Piezo to 5083/5084 Control Panel Wiring Diagram 2. Connect a jumper wire across terminals 6 and 11. (See Figure 3-16.) 3. Set the auxiliary relay to the ALARM selection in System Options in programming. (See Section step 28.) Note: 5083 and 5084 installations using a secondary touch-tone relay or a ground start telephone system CAN- NOT use the alarm output
32 Installation Instructions 3.6 Model 5076 Heater Kit The Model 5076 Heater Kit can be used with the Model 5083/5084 Control Panel. It is designed to maintain the temperature inside the cabinet above 32 F when the outside temperature is -20 F. The heater uses a self-regulating positive temperature coefficient (PTC) material for the heating element. The heater is powered by a 16.5 VAC, 50VA Class II transformer. The heater bracket is electrically insulated from the heater element To Install the 5076 Heater 1. Remove the four #6 nuts that retain the keypad circuit board. (See Figure 3-17.) Figure 3-17 Keypad Circuit Board Retaining Nuts 2. Replace them with the threaded stand-offs. 3. Mount the 5076 on the threaded stand-offs with the #6 nuts and lock-washer provided. (See Figure 3-18.) 4. Connect the 16.5 VAC Class II transformer to the two terminals on the 5076 Heater. (See Figure 3-18.)
33 Series 5000 Entry System Installation/Operation Manual Figure 3-18 View of 5076 Mounted
34 Section 4 Operation Modes Operating modes are used to program tenant and time information and to select system operating features such as telephone, etc. Table 4-1 shows the seven different operating modes and a description of each. (See 4.2 for more information about operation modes.) Table 4-1: Operation Modes and Descriptions Operation Mode Description Comments 0 1 Programs System Options. The following information can be programmed in the System Options : Rotary dialing (yes/no), USA rotary (yes/no), Speaker on (yes/no), Ground start (yes/no), * before 6 (yes/no), PBX number, apartment number length, Call length, Door time, Speaker Volume, Hide Codes (yes/no), Aux Time, and System Message. System Messages select the message displayed to visitors and tenants at the entry system. Choose either ENTER APT#, ENTER SUITE #, or ENTER UNIT #, ENTER CODE #. User Options. This mode is used to add, edit and remove a user from the system. Each user has the following data fields which may be programmed in this mode; user number, user code, phone number, dial PBX, door enabled, aux enabled. Time Set. Used to set the real time clock and the auxiliary enable/disable 2 times. 3 Open Door Relay. Activates the door relay. 4 Activate Auxiliary Relay. Used to activate auxiliary door relays at any time. 5 6 Telephone. Make the r 5084 a normal telephone so it can be used to make a phone call outside the complex system. CLR Memory? Deletes all programmed system and user information. These operating modes are used to program the system. Theses operating modes are system features and do not perform any system programming. This operation mode resets the system to factory defaults
35 Series 5000 Entry System Installation/Operation Manual 4.1 Entering, Changing Options and Exiting Operating Modes This section contains information that will help you enter, exit and change different selections in the various operating modes To enter an operating mode: 1. Press * followed by the operating mode number (0 through 6). See Table 4-1 for choices. The display will show ACCESS #. 2. Enter the 6-digit access code. (Factory default is ) 3. Press * If The Access Code Is Not Known: 1. Turn the power switch to the off position. 2. Press and hold the 0 key on the keypad while turning the power switch back to the on position. The system will power up in the programming mode. The display will show ACCESS # (see section 4.1.1) To Change a Selection. 1. Press # to clear display. 2. Enter new data. If the programming field your in has pre-selected choices, press any number key (0-9) to toggle through the selections. 3. When the display shows the choice you want, Press * To Skip a Selection. To skip a step without changing the selection of the option: Press * To Exit Any Operating Mode. 1. Press # #
36 Operation Modes 4.2 Operating Modes This section gives step-by-step instructions for each mode. It is recommended that you read through Section 4.1 and the Operating Mode steps once to become familiar with the procedure. After you are familiar with the procedure you may find the Quick Chart easier to use. (See Section 4.3.) Operation Mode 0: System Options In Operation Mode 0 system options can be programmed. System options are; access code, rotary dialing, usa rotary, speaker on/off, hide codes, * before 6, PBX access #, user number length, call length, door time, aux time, system message, CIC #, aux relay enable/disable and aux time window enable/disable. To enter Operation Mode 0: 1. Press * then 0. The display will show ACCESS #. 2. Enter the 6-digit access code. (Factory default is ) The display will show SYSTEM OPTIONS 3. Press *. 4. The display will show ACCESS CODE XXXXXX. (X = a number from 0-9.) 5. Enter new 6-digit access code then *. If you don t wish to change the access code just press *. 6. Display shows ROTARY DIALING? YES or NO. YES = rotary dialing NO = TouchTone dialing 7. Press any key other than * or # to toggle between yes or no. 8. Press *. The display shows USA ROTARY? YES or NO. YES = USA rotary standards NO = EURO rotary standards 9. Press any key other than * or # to toggle between yes or no. 10. Press *. The display shows SPEAKER ON? YES or NO. YES = speaker is on while dialing NO = speaker off during dialing
37 Series 5000 Entry System Installation/Operation Manual 11. Press any key other than * or # to toggle between yes or no. 12. Press *. The display shows HIDE CODES? YES or NO. YES = Hide access & keyless entry codes while entering them NO = Show access code & keyless entry code while entering them 13. Press any key other than * or # to toggle between yes or no. 14. Press *. The display shows * BEFORE 6 YES or NO YES = visitor must press * before tenant can open door by pressing 6. NO = tenant just needs to press 6. This feature is used to prevent unauthorized entry using a TouchTone beeper to activate doorstrike. 15. Press any key other than * or # to toggle between yes or no. 16. Press *. The display will show PBX ACCESS # XX. X = a number from Enter the number (up-to two digits) necessary to access a PBX system. This may be necessary for phone lines that are run through a PBX system. 18. Press *. The display shows USER # LENGTH X. X = a number from 1-8 which is the number of digits to be used on the user directory. 19. Enter 1, 2, 3, or 4 depending on the number of digits to be used on the user directory. 20. Press *. The display shows CALL LENGTH This is how much time is allowed between the time the system is finished dialing and the time it automatically hangs-up, seconds. 21. Enter the Call Length time. 22. Press *. The display shows DOOR TIME This selects the length of time (1-255 seconds) the door relay will be activated for entry. 23. Enter the Door Time. 24. Press *. The display shows AUX TIME This selects the length of time (1-255 seconds) the auxiliary relay will be activated. If aux relay is programmed as Alarm or Ground Start, aux time is ignored. 25. Enter the auxiliary relay time
38 Operation Modes 26. Press *. The display shows SYSTEM MESSAGES ENTER APT # This selects the display message that the user will see during normal operation. 27. Press any number to toggle through the display message choices. (See Table 4-2 for list of choices.) 28. Press *. The display shows AUX RELAY DISABLED If enabled the aux relay is operational as a secondary tone or rotary controlled relay. If Alarm is selected the auxiliary will be used as an alarm output. If ground start is selected the auxiliary relay will be used for phone systems that use ground start phone operations. If disable the auxiliary relay will not operate. If ring detect is selected the control panel will activate a sounding device connected to the auxiliary relay, that will notify an attendant that there is an incoming call to the control panel (see Section 6.5 for operation). 29. Press any number to toggle the display between ENABLE, ALARM, GROUND START, RING DETECT or DISABLE. 30. Press *. The display shows AUX TIME WINDOW ENABLED This option enables or disables the programmed auxiliary time window which is programmed in operating mode 2 Time Set. If Aux Time Window is enabled and Aux Relay is enabled, then the aux relay will only be enabled during the programmed time window. If Aux Time Window is disabled and Aux Relay enabled, then the auxiliary can be used anytime (see Section 6.3 for Auxiliary Door Access Operation). If Aux Relay is disabled, then Aux Time Window will not function. If the continuous option is chosen then the auxiliary relay will be energized for the entire aux time window. 31. Press any number to toggle the display between ENABLE, DISABLE and CONTINUOUS. 32. Press *. The display shows SPEAKER VOLUME The speaker volume can be set to low, medium, or high. 33. Press any number to toggle to the desired choice. 34. Press *. The display shows ANSWER RINGS Enter the number of rings before the entry system will automatically pick up to communicate with the up/down loading computer. Range from 0 to 15. Note: If 0 is selected for Answer Rings the control panel will never begin communication with up/down loading software
39 Series 5000 Entry System Installation/Operation Manual Operation Mode 1 User Information Operation Mode 1 is used to program the User Information. Operation Mode 1 can be used to add, edit or delete user information. To program user information: 1. Press * then 1. The display showsaccess # 2. Enter the 6-digit access code. (Factory default is ) The display shows USER OPTIONS USER # At this point you can choose to Add Edit or Delete a user. To Add a user, refer to Section To Edit a user, refer to Section To Delete a user refer to Section Add User Information To add a user: 1. Do steps 1 through 2 of Section Enter the new user number. This the number that appears next to the user s name on the directory. The user number can be 1 to 8 digits in length and is set in system options (see section step 18 for step-by-step instructions for User # Length). 3. Press *. The display shows USER PHONE 4. Enter the users phone number. Up to 20 digits in length. 5. Press *. The display will show USER CODE ( is the default user code) The user code is the code the user will enter into the system to gain keyless entry. The user must press # and then their user code to gain keyless entry. 6. Enter the user code number. The user code must be 4 to 6 digits in length. 7. Press *. The display shows DIAL PBX YES or NO If the system needs to dial the programmed PBX access number (see for information about PBX access number) before dialing this users phone number then set this option to YES. 8. Press any key to toggle between Yes or No
40 Operation Modes 9. Press *. The display shows DOOR ACCESS YES or NO This feature allows the user a keyless enter option. If programmed yes the tenant can enter # followed by their user code to gain keyless entry to the building. If programed no the tenant must use a key to enter building. 10. Press any key to toggle between Yes or No. 11. Press *. The display shows AUX ACCESS YES or NO This feature allows the user to active the auxiliary relay by pressing 9 when a visitor calls. 12. Press * Edit User Information To change a users information: 1. Do steps 1 through 2 of Section Enter the number of the user you wish to edit. 3. Press *. The display shows USER PHONE 4. Enter the users phone number. Up to 20 digits in length. 5. Press *. The display will show USER CODE (the default user code is blank) The user code is the code the user will enter into the system to gain keyless entry. The user must press # and then their user code to gain keyless entry. 6. Enter the user code number. The user code must be 4 to 6 digits in length. 7. Press *. The display shows DIAL PBX YES or NO If the system needs to dial the programmed PBX access number (see for information about PBX access number) before dialing this users phone number then set this option to YES. 8. Press any key to toggle between Yes or No. 9. Press *. The display shows DOOR ACCESS YES or NO This feature allows the user a keyless enter option. If programmed yes the tenant can enter # followed by their user code to gain keyless entry to the building. If programed no the tenant must use a key to enter building. 10. Press any key to toggle between Yes or No
41 Series 5000 Entry System Installation/Operation Manual 11. Press *. The display shows AUX ACCESS YES or NO This feature allows the user to active the auxiliary relay by pressing 3 when a visitor calls. 12. Press * Delete User Information To delete a user from the system: 1. Do steps 1 through 2 of Section Enter the number of the user you wish to delete. 3. Press # to clear the user number. 4. Press *. 5. Press ## to exit Operating Mode 2 Time Set Operating Mode 2 is used to set the real-time clock and the auxiliary relay enable/disable times. To set the real-time clock and auxiliary enable/disable times: 1. Press * then 2. The display will showaccess #. 2. Enter the 6-digit access code. (Factory default is ) The display shows TIME SET 3. Press *. The display shows SET SYSTEM TIME XX:XX X = a time based on a 24 hour clock (military time). 4. Enter the correct time in military time. Example 1:00 pm in military time = 13: Press *. The display shows 12 hour time? YES or NO This feature selects whether the time will be displayed in a 12 -hour (with am & pm) or 24-hour (military) format. Yes = 12-hour display. No = 24-hour display. 6. Press any key to toggle between Yes or No. 7. Press *. The display shows AUX ENABLE TIME XX:XX X = a number from 0-9. Enter time based on a 24 hour clock (military time). This feature sets the beginning time of the auxiliary relay time window
42 Operation Modes 8. Enter the time you wish to enable the auxiliary door relay. 9. Press *. The display shows AUX DISABLE TIME XX:XX. X = a number from 0-9. Enter time based on a 24 hour clock (military time). This feature sets the ending time of the auxiliary relay time window. 10. Enter the time you wish to disable the auxiliary door relay. 11. Press * Operating Mode 3 Activate Door Relay Operating Mode 3 activates door relay for the time set in Door Time of the system options (see step 22 for step-by-step instructions on how to set Door Time). To activate door relay use the following procedure: 1. Press * then 3. The display will showaccess # 2. Enter the 6-digit access code. (Factory default is ) The display shows DOOR IS OPEN. The door relay stays active for the door time Operating Mode 4 Activate Auxiliary Relay Operating Mode 4 activates the auxiliary relay when Aux Relay is programmed as Enabled (see also Section step 28 for Aux relay programming). To activate the auxiliary relay: 1. Press * then 4. The display will showaccess # 2. Enter the 6-digit access code. (Factory default is ) The display shows DOOR IS OPEN. The auxiliary door remains open for door time
43 Series 5000 Entry System Installation/Operation Manual Operating Mode 5 Telephone Operating Mode 5 is used to make the 5083 or 5084 control panel act as a normal phone. To use the control panel as a normal phone: 1. Press * then 5. The display will showaccess #. 2. Enter the 6-digit access code. (Factory default is ) 3. Enter the phone number you wish to call. 4. Press *. 5. Press # to hang-up. 6. Press # again to exit Operating Mode 6 Memory Clear Operating Mode 6 deletes all user information and resets the system options back to factory defaults. To clear the control panel memory: 1. Press * then 6. The display will show ACCESS #. 2. Enter the 6-digit access code. (Factory default is ) The display shows 3. Press any key to toggle between Yes or No. When the display shows 4. Press * 5. Press # # to Exit. CLR MEMORY? NO XX:XX (current time) CLR MEMORY? YES
44 Operation Modes 4.3 Quick Chart The Quick chart is to be used once your have become familiar with the programming procedures discussed in Sections 4.1 and 4.2. Table 4-2: Quick Chart Operating Mode 0 Display Shows/ Feature ACCESS CODE ROTARY DIALING? USA ROTARY? SPEAKER ON? HIDE CODES? * BEFORE 6 PBX ACCESS # USER # LENGTH CALL LENGTH DOOR TIME AUX TIME Choices Default Comments Enter a six digit number to access any operation mode See Section step 4 for step-by-step instructions.) YES or NO NO Yes = Rotary dialing. No = TouchTone dialing. (See Section step 6 for step-by-step instructions.) YES or NO YES Yes = USA rotary dialing standards. No = EURO rotary dialing standards. (See Section step 8 for step-by-step instructions.) YES or NO NO Yes = Speaker will remain on while dialing. No = Speaker will be off while dialing (See Section step 10 for step-by-step instructions.) YES or NO NO Yes = Hide Access and Keyless Entry codes at the display when entering them. No = Don t hide Access and Keyless Entry codes at the display when entering them. (See Section step 12 for step-by-step instructions.) YES or NO NO Yes = * must be dialed before 6 to gain access No = * not necessary. (See Section step 14 for more information). Enter the one or two digit number needed to access the PBX system. Enter any digit from 1 to Seconds 255 seconds Blank The system will dial the number programmed for PBX access before the phone number is dialed. (See Section step 16 for step-by-step instructions.) 4 Specify the number of digits to be used in the apartment directory. (See Section step 18 for step-by-step instructions.) How much time is allowed between the time the system is finished dialing and the time it automatically hang up. (See Section step 20 for step-by-step instructions.) Seconds 5 seconds The length of time the door relay will be activated for visitor entry. (See Section step 22 for step-by-step instructions.) seconds 5 seconds The length of time the auxiliary relay will be activated for entry. (See Section step 24 for step-by-step instructions.)
45 Series 5000 Entry System Installation/Operation Manual Operating Mode 0 (Cont.) Display Shows/ Feature SYSTEM MESSAGE AUX RELAY AUX TIME WINDOW SPEAKER VOLUME ENTER APT # ENTER SUITE # ENTER UNIT # ENTER CODE # Enabled, Alarm, Ground Start or Disabled Enabled, Disabled, or Continuous LOW MEDIUM HIGH ENTER APT # Disabled Disabled LOW Change the display message to accommodate the installation site. (See step 26 for step-by-step instructions.) If enabled the aux relay is operational. If Alarm is selected the auxiliary will be used as an alarm output. If ground start is selected the auxiliary relay will be used for phone systems that use ground start phone operations. If disable the auxiliary relay will not operate. (See step 28 for step-by-step instructions.) If this feature is enabled the system will make the auxiliary relay operable during the programmed time window. The time window On/Off times are programmed in the Operating Mode 2 Time Set. (See Section step 30 for step-by-step instructions.) Continuous means that the relay will be energized for the entire Aux Time Window. This feature selects the volume of the system speaker. This allows you to adjust the speaker volume to facilitate the installation environment This feature set the number of rings before the ANSWER RINGS control panel will answer the phone to begin communication with the up/down loading software. USER NUMBER Blank Enter the number of the user as listed on user directory. See Section for step-by-step procedure. USER PHONE Blank Enter the phone number to the user s office/ apartment. See Section for step-by-step procedure. USER CODE Blank Enter the code the user will use for keyless entry. See Section for step-by-step procedure. 1 User Options DIAL PBX No If the user s phone number requires a PBX access number (see Operating Mode 0) dialed before dialing select Yes. See Section for step-by-step procedure. DOOR ACCESS No Yes, enables keyless entry for the user being programmed. No, disables keyless entry for that user. See Section for step-by-step procedure. AUX ACCESS No Yes, allows the user to energize the aux. relay with a 9 from user phone. 2 Time Set Sets the real-time clock and auxiliary enable /disable times. See Section for step-by-step procedure. 3 Activate Door Relay See Section for step-by-step procedure. 4 Activate Auxiliary Disabled See Section for step-by-step procedure. Relay 5 Telephone operation Enter number of location you wish to call. Press # to hang up. Table 4-2: Quick Chart Choices Default Comments N/A Makes the 5083/5084 Control Panel into a normal telephone. See Section for step-by-step procedure. 6 CLR MEMORY Yes or No No See Section for step-by-step procedure
46 Section 5 Testing and Troubleshooting This section contains information on how to test and trouble shoot both the 5083 and 5084 Control Panels /5084 Field Test This section describes the procedures to field test a 5083 and 5084 Control Panel. **Important Notice** Due to wide variations in telephone company exchange switching equipment, Silent Knight can no longer guarantee that the 5000 Series Apartment Entry System will function properly when used to decode the digit 6 from rotary (dial type) telephones. For those exchanges where rotary phones will not work, each apartment must have a Touch-Tone telephone Test the Doorstrike Operation To test the doorstrike operation on a 5083 or 5084 control panel: 1. Press #. 2. Enter a valid user access code (programmed in section step 5.) Note: Keyless entry will only operate if the Door Access feature has been selected as yes in Section step 9. The display shows DOOR IS OPEN. Verify the door is open. The door relay will remain active for the Door Time (see Section step 22) Test the Dialing Operation This test will require the assistance of a resident caretaker or tenant (referred to as the assistant in the following procedure). To test the dialing operation: 1. At the message prompt enter the correct user number of the assistant. 2. When the assistant answers, identify yourself. The phone will automatically hang up when the Call Length has expired (see Section step 20). Both the tenant and the visitor will hear a short warning beep 15 seconds before the system hangs up. 3. The assistant will then press or dial 6 on the telephone. The door strike will remain open for the programmed Door Time (see Section step 22). Note: The tenant (assistant) can disconnect the phone, before entering 6, by pressing #
47 Series 5000 Entry System Installation/Operation Manual 5.2 Satellite Field Test This section describes the procedures to field test Remote Satellite Units Test the Doorstrike Operation To test the doorstrike operation on a satellite control panel: 1. Press #. 2. Enter a valid user access code (programmed in Section step 5). Note: Keyless entry will only operate if the Door Access feature has been selected as yes in Section step 9. The display shows DOOR IS OPEN. Verify the door is open. The door relay will remain active for the Door Time (see Section step 22) Test the Dialing Operation This test will require the assistance of a resident caretaker or tenant (referred to as the assistant in the following procedure). To test the dialing operation: 1. At the message prompt enter the correct user number of the assistant. 2. When the assistant answers, identify yourself. The phone will automatically hang up when the Call Length has expired (see Section step 20). Both the tenant and the visitor will hear a short warning beep 15 seconds before the system hangs up. 3. The assistant will then press or dial 6 on the telephone. The door strike will remain open for the programmed Door Time (see Section step 22). Note: The tenant (assistant) can disconnect the phone, before entering 6, by pressing #
48 Testing and Troubleshooting 5.3 Troubleshooting This section contains information that will help avoid problems down the road in an installation site as well as standby voltage readings and error messages To Avoid Problems Telephones without polarity protection will operate the system 50% of the time. The telephone company will correct this problem after you contact them. Any TouchTone phones manufactured before 1975 may be affected. Telephone systems using a concentrator will not generate a large enough pulse to be decoded when using rotary telephones. If these symptoms occur call the telephone company to verify if a concentrator is being used. Do not share telephone lines when using the 5000 Entry System. Wire runs to satellite units from the master unit should not exceed guide lines described in Section Satellite Satellite Master Unit Satellite Satellite Figure 5-1 Block diagram of the 5000 Entry System Hub Never connect the remote satellite units while power is supplied to the control panel. If an attempt is made to install a satellite with hot wires, the equipment may be damaged. Only one unit in the system can be used as a Master unit all other units must be programmed as a satellite unit (see Figure 5-1). Each satellite unit must use a unique SBUS ID. (See Section for wiring and configuring a master and satellite panels.) All connections made between the control panel and the remote satellites must be tight. Any loose connections WILL cause problems. Any splice points should be soldered not crimped. Four Satellites Max. If frequent or lengthy power outages are expected, it may be necessary to add more battery capacity. This will increase the time the system will operate without AC power
49 Series 5000 Entry System Installation/Operation Manual Standby Electrical Voltages Table 5-1 shows the correct standby voltages for the various terminals on the 5083/5084 Control Panel. Table 5-1: 5083/5084 Standby Voltages Between Terminals Voltage 1 to VAC 8 to VDC 9 to VDC 10 to VDC 11 to VDC 11 to VDC 11 to VDC System Messages This section lists the possible error massages that may be seen at the 5083/5084 Control Panel. (See Table 5-2.) Table 5-2: Error Messages and Meanings System Message TRY AGAIN NO ROOM TO ADD NOT AUTHORIZED SYSTEM TIMEOUT INVALID CODE!!CODE TAMPER!! Meaning This message will display during programming, if the entered data is out of range, or has too many or to few characters. During user operation this message will appear to indicate that a user is not found. User information memory location is full. System can have up to 1000 users. This message will appear during user operation if the user code or aux relay is not enabled and it is attempted to be used. This message indicates the call time length has expired. If an incorrect user or access code is entered this message will display. If four consecutive invalid access or user codes have been entered the alarm relay will energize and this message will be displayed
50 Section 6 User Operation 6.1 Visitor Operation 1. Visitors locate the user number next to the name of the tenant/resident they wish to visit. 2. When Enter Apt. # (see Section step 26 to change display message) is indicated by the LCD display, they enter the number on the keypad. The tenant is automatically dialed. After the visitor has spoken with the tenant, the tenant can remotely activate the doorstrike by pressing or dialing a 6 on his or her phone. The tenant may also hang up the 5083/84, before entering 6, by pressing or dialing #. **Important Notice** Due to wide variations in telephone company exchange switching equipment, Silent Knight can no longer guarantee that the 5000 Series Apartment Entry System will function properly when used to decode the digit 6 from rotary (dial type) telephones. For those exchanges where rotary phones will not work, each apartment must have a Touch-Tone telephone. If the tenant has not pressed a valid key, the user must press # to hang up the phone. 6.2 Tenant Access Operation The tenant can operate the doorstrike directly from the keypad in the lobby without using a building door key by: Pushing #, then entering their user access code. The user access code is programmed by the caretaker or installer. If the code entered is valid the doorstrike will open. the display will show: DOOR IS OPEN XX:XX PM (Where XX:XX is the system time.) If the access code is invalid an INVALID CODE will be displayed. If there are four consecutive errors the ALARM output will activate for programmed Aux Time to discourage tampering
51 Series 5000 Entry System Installation/Operation Manual 6.3 Auxiliary Door Access Operation The auxiliary door may be programmed to be active during certain hours of the day. It may only be activated during the time that the Aux Time Window. When a visitor calls a tenant, the user can press a 9 to activate the Auxiliary relay. The auxiliary relay may also be activated by entering operation mode 4 (see Section 4.2.5). If the Auxiliary Relay is programmed for Continuous then the auxiliary relay will remain active for the entire duration of the Aux Time Window (see Section step 7 through step 10 to set Aux time window parameters). 6.4 Postal Access Operation Turning the postal key in the lock will automatically open the door. The mail carrier then has access to the mail boxes inside the building. 6.5 Door Attendant Notification Operation In installations where a door attendant is stationed at the control panel, a tenant can call the attendant to inform him that they will have a guest arriving and provide the attendant with the visitors name, and the approximate time of arrival. When the tenant wishes to contact the door attendant they dial the phone number to the control panel. When the control panel detects ring voltage the auxiliary relay activates a sounding device (see Section for installation example of sounding device) to notify the attendant of an incoming phone call. When the sounding device activates the attendant presses the 5 button to answer. The attendant can hang up the phone by pressing the * button
52 Section 7 Programming information record This section is used to record and store the programmed system options and the user information. Table 7.1 System Options Record Use the following Table 7-1 to record the programmed System Options. Table 7-1: System Options Record Programming Option ACCESS CODE ROTARY DIALING? USA ROTARY? SPEAKER ON? HIDE CODES? * BEFORE 6 PBX ACCESS # USER # LENGTH CALL LENGTH DOOR TIME AUX TIME SYSTEM MESSAGE SPEAKER VOLUME AUX RELAY AUX TIME WINDOW Your Selection Notes
53 Series 5000 Entry System Installation/Operation Manual 7.2 User Information Record Table 7-2 has spaces for ten user s information, make as many copies of this table as necessary to record all system user information. Table 7-2: User Information Record User Name Programmable Options USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS Selection Notes
54 Programming information record Table 7-2: User Information Record User Name Programmable Options Selection Notes USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS
55 Series 5000 Entry System Installation/Operation Manual
56 Silent Knight Fire Product Warranty and Return Policy General Terms and Conditions All new fire products manufactured by Silent Knight have a limited warranty period of 18 months from the date of manufacture against defects in materials and workmanship. See limited warranty statement for details. This limited warranty does not apply to those products that are damaged due to misuse, abuse, negligence, exposer to adverse environmental conditions, or have been modified in any manner whatsoever. Repair and RA Procedure All products that are returned to Silent Knight for credit or repair require a RA (Return Authorization) number. Call Silent Knight Customer Service at or between 8:00 A.M. and 4:45 P.M. CST, Monday through Friday to obtain a return authorization number. Silent Knight Technical Support is available at between 8:00 A.M. and 6:00 P.M. CST, Monday through Friday. RA number must be prominently displayed on the outside of the shipping box. See return address example under Advanced Replacement Policy. Include a packing slip that has the RA number, a content list, and a detailed description of the problem should be included with each return. All products returned to Silent Knight must be sent freight pre-paid. After product is processed, Silent Knight will pay for shipping product back to customer via UPS ground. Return the Silent Knight product circuit board only. Products that are returned in cabinets will be charged an additional $50 to cover the extra shipping and handling costs over board only returns. Do not return batteries. Silent Knight has the authority to determine if a product is repairable. Products that are deemed un-repairable will be returned to the customer. Product that is returned that has a board date code more than 18 months from date of manufacture will be repaired and the customer will be assessed the standard Silent Knight repair charge for that model. Advanced Replacement Policy Silent Knight offers an option of advance replacement for fire product printed circuit boards that fail during the first 6 months of the warranty period. For advance replacement of a defective board contact your local Silent Knight Distributor or call Silent Knight at or to obtain a RA (Return Authorization) number and request advanced replacement. Customers without a Silent Knight account must use a MasterCard, Visa, or American Express credit card to get an advance replacement.
57 A new or refurbished board will be shipped to the customer. The customer will initially be billed for the replacement board but a credit will be issued after the repairable board is received at Silent Knight. All returned products must comply with the guidelines described under General Terms and Conditions. The defective board must be returned within 30 days of shipment of replacement board for customer to receive credit. No credit will be issued if the returned board was damaged due to misuse or abuse. Repairs and returns should be sent to: Silent Knight Attn: Repair Department 7550 Meridian Circle Suite 100 Maple Grove, MN RA Number: Limited Warranty Silent Knight warrants that the products of its manufacture shall be free from defects in materials or workmanship for 18 months from the manufacturing date code on the printed circuit board, if such goods have been properly installed, are subject to normal proper use, and have not been modified in any manner whatsoever. Upon return of the defective product, Silent Knight will at its sole discretion, either repair or replace, at no cost, such goods as may be of defective material or workmanship. Customers outside the United States are to return products to their distributor for repair. Silent Knight SHALL NOT UNDER ANY CIRCUMSTANCES BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM LOSS OF PROPERTY OR OTHER DAMAGE OR LOSSES OWING TO THE FAILURE OF Silent Knight PRODUCTS BEYOND THE COST OF REPAIR OR REPLACEMENT OF ANY DEFECTIVE PRODUCTS. Silent Knight MAKES NO WARRANTY OF FITNESS OR MERCHANTABILITY AND NO OTHER WARRANTY, ORAL OR WRITTEN, EXPRESS OR IMPLIED, BEYOND THE 18 MONTH WARRANTY EXPRESSLY SPECIFIED HEREIN.
58 7550 Meridian Circle Maple Grove, MN Fax: Silent Knight Part Number D, 01/03
Instruction Manual PC55O. With PC5OORK Keypad. 1996, 2002 Digital Security Controls Ltd. Toronto, Canada Printed in Canada 29000534 R3
Instruction Manual 1996, 2002 Digital Security Controls Ltd. Toronto, Canada Printed in Canada 29000534 R3 PC55O With PC5OORK Keypad Industry Canada Notice NOTICE: The Industry Canada label identifies
INSTRUCTION MANUAL PC15OO/155O WITH LED615 KEYPAD
INSTRUCTION MANUAL PC15OO/155O WITH LED615 KEYPAD Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that
Serial Adapter Module. Supplement. Part No. 303124-A Rev 01 November 1998. *303124-A Rev 01*
Serial Adapter Module Supplement Part No. 303124-A Rev 01 November 1998 *303124-A Rev 01* 4401 Great America Parkway 8 Federal Street Santa Clara, CA 95054 Billerica, MA 01821 Copyright 1998 Bay Networks,
Instruction Manual. version 1.0
Instruction Manual version 1.0 Table of Contents About Your ADT Security System 1 Fire Detection 1 Testing 1 Monitoring 1 General System Operation 1 System Information 2 Access Codes 4 Arming the System
Operation Manual Software Version 1.1
Operation Manual Software Version 1.1 W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer.
First Data FD130 Terminal. Quick Set-up Guide
First Data FD130 Terminal Quick Set-up Guide Thanks for choosing a First Data Terminal. First Data Terminals are some of the fastest, most secure point-of-sale terminals available. Installation is quick
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
Simon Security System. User Guide. Technical Manuals Online! - http://www.tech-man.com. 466-1871-01 Rev A June 2004. Part No: 60-875 600-1012
) *(6HFXULW\ 466-1871-01 Rev A June 2004 ZZZ*(6HFXULW\FRP Part No: 60-875 600-1012 Doors & Windows Motion Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time
Simon Security System. User Guide. 466-1871 Rev F September 2002. Part No: 60-875 ZZZ*(,QWHUORJL[6HFXULW\FRP. System Status HOME SECURITY
) 466-1871 Rev F September 2002 *(,QWHUORJL[ ZZZ*(,QWHUORJL[6HFXULW\FRP Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion
Simon Security System. User Guide. 466-1871 Rev J May 2003. Part No: 60-875 ZZZ*(,QWHUORJL[FRP. System Status HOME SECURITY. Windows Sensors.
) 466-1871 Rev J May 2003 *(,QWHUORJL[ ZZZ*(,QWHUORJL[FRP Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor On
Simon Security System. User Guide. 466-1871 Rev H April 2003. Part No: 60-875 ZZZ*(,QWHUORJL[FRP. System Status HOME SECURITY. Windows Sensors.
) 466-1871 Rev H April 2003 *(,QWHUORJL[ ZZZ*(,QWHUORJL[FRP Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2 3/4 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX
ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX INSTALLATION INSTRUCTIONS Step 1. Determine the position for the Hands-free phone in the elevator phone
WARNING NT9010 www.dsc.com
WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
GSM Door Phone System
GSM Door Phone System System Installation, Setting and Operation Manual User Manual (263-S V1) Please read this user manual completely before operating this system and keep it in a safe place for future
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Owner s Manual. 1803, 1808, 1810 Telephone Entry Systems
Owner s Manual 1803, 1808, 1810 Telephone Entry Systems DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1800-060 REV S, 3/14
Group Videoconferencing Systems
Group Videoconferencing Systems MediaConnect 8000 Series Rollabout and Compact Systems Getting Started Guide DOC01161 Rev. 2.0 12.01 2001 VCON Ltd. All Rights Reserved. Information in this document is
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Tek-ENTRY Telephone Entry System
IL573 SECTION A Rev. 12-12/2009 Tek-ENTRY Telephone Entry System Phone-Line Version Operation, Installation and Service Manual Alpha Communications 42 Central Drive Farmingdale, NY 11735-1202 Phone: (631)
Dialog Telephone Interface Module Installation Sheet
Dialog Telephone Interface Module Installation Sheet Description The Dialog Telephone Module (DTIM), model number 60-879- 95R, is a battery operated communication link between the security system control
DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS
Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short
466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide
) *(6HFXULW\ 466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
PagePac PAGEPAL V-5335700
PagePac Issue 3 by PAGEPAL V-5335700 INTRODUCTION The PagePal unit interfaces most telephone systems (PBX, KTS, Centrex) to virtually any public address audio system. In addition, PagePal furnishes inputs
PagePac Door Phone Controller V-5324001 Installation and Operation Manual
PagePac by ISSUE 1 PagePac Door Phone Controller V-5324001 Installation and Operation Manual 947177 Contents 1 Introduction 1-1 Using This Manual 1-2 The PagePac Door Phone Controller 1-3 Features 1-3
Installation & Operation Instructions
Tel-A-Greeter 204 Installation & Operation Instructions Please leave these instructions with the unit at all times Tel-A-Greeter 204 Rev. 04/19/2000 Table of Contents Limited Warranty and Limitation of
Auto Dialer. Manual E-921APQ E-921GPQ
Troubleshooting: Auto dialer will not arm/disarm Auto dialer will not dial out Unit doesn t respond to a call-back Difficulty in activating room monitor by telephone remote control Make sure that you have
Operating Guide Manuel de l utilisateur
Operating Guide Manuel de l utilisateur Model RF-110 Modèle RF-110 English Thank you for purchasing this Ringmaster; please read this operating guide carefully before use and keep it for future reference.
-Helping to make your life betterwww.person-to-person.net
Household Telephone Management System Built on Interceptor ID Technology Owner/Operation Manual Telephone Management System- Model P2P101 Call Receiver - Model P2P301 (Receiver may be sold separately)
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS
EHD TRACK LEVEL, (SET LEVEL ON PLASTIC HEADER. DO NOT PLACE LEVEL ON ALUMINUM TRACK.) TRACK IS FLUSH WITH TOP OF HEADER JUNCTION BOX IDLER PULLEY LOCATOR PINS LOCATOR PINS OPERATOR DOOR STOP JUNCTION BOX
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
VPP T1250 Emergency Telephones Installation & Operation Manual
VPP T1250 Emergency Telephones Installation & Operation Manual T1250B T1250S T1250E Janus is a brand of Avire Avire Inc 415 Oser Avenue, Suite Q, Hauppauge, New York 11788 Phone: 631 864 3699 Toll Free:
Installation & Operation Manual for EC-8 Phone Line Consolidator
Installation & Operation Manual for EC-8 Phone Line Consolidator For Use With Talk-A-Phone Hands-Free Emergency Phones Section Page Getting Started 2 Hardware Installation 3 Software Programming 5 Operation
3 Slot Payphone Controller
5A2 3 Slot Payphone Controller The 3 Slot Payphone -- Part of American History Building a Coin Relay Controller Version S1BX Instruction Manual and Safety Precautions It is very important that for your
AT&T. PARTNER Plus Door Phone. Installation and Operation Manual
AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a
FD200 Ti Terminal. quick Set-Up Guide
FD200 Ti Terminal quick Set-Up Guide Thanks for choosing a First Data FD200 Ti Terminal. First Data Terminals are some of the fastest, most secure point-of-sale terminals available. Installation is quick
BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell
Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault
11/16/92 AT&T. AT&T Door Phone Controller. Installation and Operation Manual
11/16/92 AT&T AT&T Door Phone Controller Installation and Operation Manual 1992, AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-315 0II722050-055 Issue 3, November 1992 NOTICE Every effort was
Emergency Dialer DIAL-ALERT MODEL: AD-105. www.skylinkhome.com
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-105 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :
Direct AC Wiring Option Installation Guide
Revision A Direct AC Wiring Option Installation Guide The direct AC wiring option enables you to wire AC power directly in to the ADP InTouch. The option kit contains the following parts. 25mm 12mm Caution:
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)
HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT
FBII Security System. User Guide. N9939V5 4/04 Rev. A
FBII Security System OMNI 400/OMNI 600 OMNI 624/OMNI 848 User Guide N9939V5 4/04 Rev. A Table Of Contents QUICK REFERENCE... 3 INTRODUCTION... 6 SYSTEM REFERENCE...7 ARMING THE SYSTEM... 10 DISARMING THE
LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers 11-580, 11-581, 11-582, 11-583, 11-585,11-586 and 11-589
LINE POWERED ADA TELEPHONE USER S MANUAL Use With Part Numbers 11-580, 11-581, 11-582, 11-583, 11-585,11-586 and 11-589 6200 Brent Drive, Toledo, Ohio 43611 Phone: 800-837-1066 Fax: 419-729-5764 Email:
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
Simon Security System. Installation Instructions. 466-1873 Rev F September 2002. Part No: 60-875 60-910 (Not investigated for use by UL)
) 466-1873 Rev F September 2002 *(,QWHUORJL[ ZZZ*(,QWHUORJL[6HFXULW\FRP Part No: 60-875 60-910 (Not investigated for use by UL) Doors & Motion Windows Sensors System Status HOME SECURITY Arm Disarm 1/2
B100. single-line business telephone
users guide B100 single-line business telephone B100 TELEPHONE DIAGRAM TABLE OF CONTENTS 1) FEATURES......2 1.1 FLASH 1.2 LAST NUMBER REDIAL 1.3 MUTE 1.4 HANDSET VOLUME CONTROL 1.5 DATA PORT 1.6 HEARING
Product Documentation on the World Wide Web
Hotwire M/SDSL Standalone Termination Units Models 7974-A2, 7975-A2, and 7976-A2 Installation Instructions Document Number 7900-A2-GN11-00 August 2000 Product Documentation on the World Wide Web We provide
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
ADEMCO LYNXR-I Security Systems
K14117 3/06 Rev. A ADEMCO LYNXR-I Security Systems Quick Start Guide UL LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA)
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
PHONE ACCESS USER'S GUIDE
PHONE ACCESS USER'S GUIDE For Security Systems With Ademco s V I P (VISTA Interactive Phone) U.S. PATENT No. 4791658 N6432V2 9/94 TABLE OF CONTENTS INTRODUCTION... 4 General Information... 4 Type of Telephone
About the HotWire 7900 10-Slot Standalone Shelf
TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed
8 Channel Status Input Panel model SIP-8
Description The Sine Systems model SIP-8 Status Input Panel is to be used with the RFC-1/B Remote Facilities Controller. It consists of a long PC board mounted on a 1.75 inch (1U) rack panel. The SIP-8
No Phone Line II-48 System
Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
V-2901 UNIVERSAL DOOR ANSWERING SYSTEM
VSP-V-2901 Issue 6 V-2901 UNIVERSAL DOOR ANSWERING SYSTEM INTRODUCTI The V-2901 is a Universal Door Answering System for use with any single line telephone, electronic or 1A2 key system, or PABX. These
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone
SECTION 7 - REPAIR/REPLACEMENT PROCEDURES
SECTION 7 - REPAIR/REPLACEMENT PROCEDURES INTRODUCTION Although the modular power system is designed to give long, troublefree service, some components may need to be replaced periodically. This section
SILENT KNIGHT MODEL 5207
SILENT KNIGHT MODEL 5207 Fire Control / Communicator Installation, Programming, and Operation Manual Part Number 150865 Rev. C, 04/03 Contents Section 1 Introduction.......................................................................1-1
PCM2000 Configuration Guide
2000 Configuration Guide 2012 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54501901C 1209 2 Contents SECTION I APPLICATION CONFIGURATIONS...431 Configuration
User's Manual 4110DL/4110XM
S e c u r i t y S y s t e m User's Manual 4110DL/4110XM N5100V5 9/96 TABLE OF CONTENTS SYSTEM OVERVIEW... 4 Keypads... 4 Zones... 4 Alarms... 5 Fire Protection... 5 Burglary Protection... 5 Memory of Alarm...
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access
CSP Combined Series Telephone Door Entry with Proximity Keyfob Access PD-094 Issue 3 General Description The CSP series systems are combined Door Entry Telephone and Proximity Access Systems. The entrance
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual
United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual Patents Pending INTRODUCTION Thank you for purchasing United Security Products Model AVD-45b, the single
FortiFone QuickStart Guide for FON-670i and FON-675i
FortiFone QuickStart Guide for FON-670i and FON-675i FortiFone QuickStart Guide for FON-670i and FON-675i Revision 2 September 25, 2015 Copyright 2015 Fortinet, Inc. All rights reserved. Fortinet, FortiGate,
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack
RC930 Manual 6/10/99 1:23 PM Page 1 Wireless Modem Jack Table of Contents Safety Precautions...1 Important Notes...4 Getting Started...5 System Installation...5 Connecting to Computer...6 Trouble Shooting...7
OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT
OM2260VW2 USER MANUAL VERIZON WIRELESS HOME PHONE CONNECT Welcome to Verizon Wireless Thank you for choosing Verizon Wireless Home Phone Connect. You re now connected to the power of America s most reliable
WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER
BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.
Quick Reference Guide
Quick Reference Guide Model No. KX-T7710 Attention When using the KX-T7710, keep the following conditions in mind. If there is any problem, unplug the extension line and connect a known working phone.
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE
SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
Customer Service: 1-800-288-6794 (for U.S. and Canada) Customer Service E-mail: [email protected]
Customer Service: 1-800-288-6794 (for U.S. and Canada) Customer Service E-mail: [email protected] 3 Before you begin This guide is designed to introduce you to the various installation and operational
HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
Customer Service: 1-800-288-6794 (for U.S. and Canada) Customer Service E-mail: [email protected]
Customer Service: 1-800-288-6794 (for U.S. and Canada) Customer Service E-mail: [email protected] 3 Before you begin This guide is designed to introduce you to the various installation and operational
GERONIMO ANALOGUE HEAVY DUTY TELEPHONE
GERONIMO ANALOGUE HEAVY DUTY TELEPHONE Installation and Connection Instructions K a l i k a L t d., I n n o v a t i o n H o u s e, A l e x a n d e r B e l l C e n t r e, H o p k i n s o n Wa y, A n d o
DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0
Form No. 74-00-4001 S168-195-001 Revision E DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS 52 635.0 INTRODUCTION Allied Healthcare Products, Inc. s Digital Alarm
VIDEO DOOR PHONE SYSTEM
ENGLISH VIDEO DOOR PHONE SYSTEM USER MANUAL Manual covers IH-692 Master and IH-692 Slave Monitors PRECAUTIONS BEFORE INSTALLATION Connect this unit ONLY to other compatible units. Do not connect it to
Setting Up the Cisco Unified IP Phone
CHAPTER 3 This chapter includes the following topics, which help you install the Cisco Unified IP Phone on an IP telephony network: Before You Begin, page 3-1 Understanding the Cisco Unified IP Phone 7962G
READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION
UR Series LED Upgrade Kit Includes: 48" Linear Option IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL
2 WIRE video door entry system
J J N P CLASSE 00 VE WIRE video door entry system 5 Description Front view WIRE handsfree colour video handset with inductive loop, preset for different types of installations, depending on the accessories
Control/Communicator Installation Manual
DAS NETWORX NX-8 Control/Communicator Installation Manual Page General Description... 2 Ordering Information... 2 Option Definitions... 2 Programming the LED Code Pads... 4 Programming the NX-8... 8 Types
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
LOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
PiSector Home security systems
PiSector Home security systems User Manual (ALM-S02) Read manual fully before use. PiSector Inc., USA, www.pisector.com Thank you for purchase this alarm system, For proper use and your safety, please
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
