FIRE DETECTION SYSTEMS. elan Fire Alarm Product Guide

Size: px
Start display at page:

Download "FIRE DETECTION SYSTEMS. elan Fire Alarm Product Guide"

Transcription

1 FIRE DETECTION SYSTEMS elan Fire Alarm Product Guide

2 elan System The unique, VES elan system is a total hardware and software solution that can provide dealers with a complete set of tools and products to grow and manage the fire alarm installation, maintenance and monitoring business. The elan product range and software tools provide real added value and cost benefits for installers and their customers along with professional, consistent and accurate reporting of the service history for the entire life of the installation. Product range: esp Business Suite - Full suite of software applications elan Panel - Analog Addressable Fire Control Panel (2 or 4 SLC loops) elan RS Panel - Analog Addressable Fire Control Panel (1 or 2 SLC loops) VESNet - Communication cards eview - Analog Addressable Serial Annunciator ematrix - Configurable floor plan Graphical Annunciators SLC Devices - Optical, heat and multi sensors. Pull stations and I/O modules Annunciation Devices - Full line of Horns & Strobes, Wall & Ceiling Ancillary Items - Fire Document Enclosure and Ancillary Enclosure VoiceAlert - Voice evacuation system

3 esp Business Suite The unique esp Business Suite is the most powerful differentiator between VES and other manufacturers. esp is a web-based service, allowing for complete control of your installations. The VES Dealer can use esp for quoting, ordering and programming the system from start to finish. Quick Quote An embedded module of esp, Quick Quote is your bidding, tracking, financial analysis and parts ordering tool. Quick Quote keeps all of your information parts, people, prices and more in one secure location. Like every other module of esp, Quick Quote is available to your employees from anywhere with an ordinary web browser. esp Discovery Discover the ease, power and savings of remote programming with esp Discovery. From a web browser, anywhere in the world, you can configure the elan panel or network with easy Drag & Drop style programming. All of your systems programming is safe, secure and backed-up in a centralized location, with redundant internet pathways. No more lost programs. No more cables or modems to maintain. You can even collaborate with co-workers anywhere in the world, via the web, to program a system. When you re ready to download, just queue it up from anywhere with internet access. esp Discovery now also supports Upload from an auto learned or existing location Virtual Panel With Virtual Panel, you re never out of touch with your elan system. A singular achievement in the industry, Virtual Panel shows you the exact display from the front of the panel with a Media Gateway. Virtual Panel works over a standard web browser from anywhere on the Local Network. This makes it an ideal solution for command centers, security offices and facilities managers. Media Gateway or Ether/DACT.

4 elan System with esp Business Suite Overview The elan system from VES is a complete, UL 9th edition and FM listed range of hardware and software tools that enables dealers to design, bid, install, service and maintain fire alarm systems using the unique and powerful esp software suite elan systems are scalable from stand-alone, singlepanel systems with 126+ devices, to fully supervised, fault tolerant networked systems utilizing up to 127 panels and over 100,000 points of protection. Because of the technological advances of our selfconfiguring VESNet network, you can now program a complete networked system as if it s a single panel. Easy Plug & Play networking allows the network to be programmed remotely with no special software or onsite computer. The VES esp Business Suite breaks the technological and training barrier to simple and secure fire systems. All of your data: quotes, programming, event logs, device sensitivity readings and much more is available anytime, on the web, from anywhere. No software or special hardware to maintain and upgrade. elan System Hardware elan Analogue Addressable Panels with support for 1, 2 or 4 SLC loops for over 500 points per panel with a single hazard networked releasing capability. SLC loop communication uses standard cable. Twisted pair or shielded is not required. Inter-panel networking uses standard CAT-5 cabling or optional Fiber Optics. World class UL Listed range of detection devices include self-calibrating optical and multisensors, heat sensors, pull stations and input/output modules. Notification devices include a full line of synchronized horns and strobes. VESNet networking allows for easy-to-install Class A communications between up to 127 control panels and remote LCD annunciators.

5 VESNet Networking The Power of Communication Each elan panel can be configured with one of three communications cards: Media Gateway, the nerve center of the networked system. NIC, for networked remote panels. Ether/DACT, for stand-alone, single panels. All inputs and outputs on all elan panels are fully programmable, enabling an entirely integrated fire system over very large areas. Integrated Modem/DACT on the elan RS panel. Complex Cause & Effect relationships are easily programmed, even between panels. No need to visit each panel on the network to configure it. The entire VESNet network is programmed at the same time, saving hours of on-site programming time. The powerful communications capability of the elan system can cut the everincreasing costs of service calls by allowing the entire system to be diagnosed remotely. Any number (up to the maximum number of nodes) of discrete VESNet LCD Networked Displays can be added, providing comprehensive indication at convenient locations.

6 elan System Schematic Loop 1 Loop 2 Loop 3 Loop 4 (if fitted) elan RS Control Panel Annunciator elan Control Panel Telco High Integrity Self-Configuring Network elan Control Panel Media Gateway Annunciator elan Control Panel eview Annunciator 24V DC ematrix

7 Monitoring Center Reduced Costs Internet Access to esp Business Suite and Access to all Installations Office Buildings Hospitals Schools / Universities Customers Hotels Apartment Complexes Improved Service Dealer Quoting Parts Ordering Maintain Customers View Service Schedules View Inspection History Produce and Store Site Configurations Configure Systems Virtual Panel Retrieve Event Log View Analog Value of Devices

8 elan Analog Addressable Fire Control Panels (2 or 4 Loops) The VF1240 and VF1220 analog addressable FACP with networked releasing, supports 2 or 4 SLC loops for a total of 500 points with a single hazard releasing capability. SLC loop communications uses standard cable twisted pair or shielded is not necessary while inter-panel networking (VESNet) uses standard CAT5 cabling. The panel may be configured with various communication cards; VF1241 and VF1221 include a Media Gateway, VF1244 and VF1224 include an Ether DACT or VF1242 and VF1222 include a NIC (Network Interface Card). Communications options support remote programming, central station monitoring, Virtual Panel, and networking. The Panel can be configured as a stand alone panel with just a few devices for a small building or Releasing System.It can also operate as the building system and Releasing System and can be part of a network with a total of 127 nodes serving a multiple building campus or a very large facility. Auto Learn capability provides a convenient method to troubleshoot new installations before final programming is loaded and remote manufacturer assistance is also available to diagnose and help correct configuration options. 2 Loops VF1220 VF1221 VF1222 VF Loops VF1240 VF1241 VF1242 VF1243 No Communicator W/ Media Gateway W/ NIC Card W/ Ether/ DACT No Communicator W/ Media Gateway W/ NIC Card W/ Ether/ DACT UL 864 9th Edition listed Multi-loop (4) analog-addressable 126 primary points per loop 500 relationships per network with 2,000 inputs and 2,000 outputs 500 primary points per panel expandable up to 800 points per panel when using devices with sub-points Up to 10,000 ft. wiring length on SLC loop 127 Panels on a Media Gateway / NIC system programmed as a single network Configurable through keypad or remotely, via esp Programmable Inputs 3 Programmable relays 5 Supervised Powered Outputs 3 Programmable Notification Appliance Circuits: 4 Power per NAC: 1.6 Amps Max Programmable outputs on SLC loop Programmable Function button on front display Fire Drill button on front display Day and night sensitivity settings Power Supply: 5.25 Amp, regulated & integrated LCD Display: 8x40 Zonal Mode: Annunciation by zone w/o individual relationships Panel Ring Modes: Common, Zonal, Stage 2 NAC Outputs programmable as Continuous, March, Temporal Program Zones as AND, OR, or Any Two (Cross Zone) Battery size: Up to 17 Ah in standard enclosure; up to 52 Ah with external cabinet Access levels: 3 Access key switch: Yes Recognized for use in High Rise One man walk test Fire Test Mode Available with semi flush trim ring Available in Red (RAL 3002) or Gray (RAL 7035) All VES controls are UL 9th Edition listed and FM approved APPROVED

9 elan RS Analog Addressable Fire Control Panels (1 or 2 Loops) elan RS is a versatile range of open protocol fire alarm control panels compatible with existing elan fire alarm panel technology. Available with one or two detection loops capable of hosting up to 250 devices. elan RS uses leading edge microprocessor based electronics to provide a flexible control system with high reliability and integrity. Suitable for all small to medium sized fire detection systems, elan RS control panels can be expanded and networked to become part of much larger systems if the need arises, therefore providing a future proof solution for any installation. With its large graphical display and ergonomic button and indicator layout, the elan RS control panel is simple and straightforward to understand for installers, commissioning engineers and end users alike. 1 Loop VF0950 VF0951 VF0952 VF0953 VF Loops VF0960 VF0961 VF0962 VF0963 VF0964 No Communicator W/ Media Gateway W/ NIC Card W/ Ether/ DACT W/ Integrated Modem/ DACT No Communicator W/ Media Gateway W/ NIC Card W/ Ether/ DACT W/ Integrated Modem/ DACT Available in Red or Gray 2 programmable NAC circuits 3 programmable relays 5.25A power supply Large graphic display Real time clock Up to 512 additional programmable I/O via I/O modules Powerful, network wide cause and effects Sensitivity adjustment and Drift Compensation Can be networked with elan control panels Compatible with eview Annunciator Same look and feel as elan range Stores 1000 last events in event log DACT connection available Compact, stylish enclosure

10 REFER TO MODEM-DACT ETHERNET INSTALLATION MANUAL WITH RELEASING VF , Rev. E02.XX AND MODEM-DACT CONFIGURATION AND REPAIR MANUAL VF , Rev.E02.XX 000AFD0002FB SIGNALING LISTED MAXIMUM POWER REQUIREMENT: ma FOR INDOOR DRY USE ONLY JACK J5 ETHERNET IS UNSUPERVISED AND POWER- LIMITED JACK 1 TELCO LINE 1 AND LINE 2 ARE SUPERVISED THIS DEVICE COMPLIES WITH PART 68 RULES FCC REG. NO.: VESAL00BVF10xx-xx REN = 00B JACK TYPE: RJ11C FIRE ALARM SUBASSEMBLY 3PBS LBL TESTED TO COMPLY WITH FCC STANDARDS THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Industry Canada Electromagnetic Compatibility, ICES-003: THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003. CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB-003 DU CANADA. REFER TO MEDIA GATEWAY INSTALLATION MANUAL WITH RELEASING VF Rev. E02.XX 000AFD0002FB SIGNALING MODEL NO.: VF MEDIA GATEWAY WITH RELEASING FIRE ALARM SUBASSEMBLY 3PBS LISTED LBL MAXIMUM POWER REQUIREMENT: 115mA FOR INDOOR DRY USE ONLY JACK J3 VESNet IS SUPERVISED AND POWER- LIMITED JACK J5 ETHERNET IS UNSUPERVISED AND POWER- LIMITED THE MEDIA GATEWAY WITH RELEASING CONTAINS A DACT AT JACK 1 TELCO LINE 1 AND LINE 2. JACK 1 TELCO LINE 1 AND LINE 2 ARE SUPERVISED TESTED TO COMPLY WITH FCC STANDARDS THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003. Industry Canada Electromagnetic Compatibility, ICES-003: CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME NMB-003 DU CANADA. THIS DEVICE COMPLIES WITH PART 68 RULES FCC REG. NO.: VESAL00BVF10xx-xx REN = 00B JACK TYPE: RJ11C REFER TO NETWORK INTERFACE CARD (NIC) INSTALLATION MANUAL WITH RELEASING VF Rev. E02.XX 000AFD0002FB SIGNALING THIS DEVICE COMPLIES WITH PART 68 RULES FCC REG. NO.: VESAL00BVF10xx-xx REN = 00B JACK TYPE: RJ11C FIRE ALARM SUBASSEMBLY 3PBS LISTED LBL MAXIMUM POWER REQUIREMENT: ma FOR INDOOR DRY USE ONLY JACK J3 VESNet IS SUPERVISED AND POWER- LIMITED THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003. Industry Canada Electromagnetic Compatibility, ICES-003: NMB-003 DU CANADA. CET APPAREIL NUMERIQUE DE LA CLASSE A EST CONFORME A LA NORME VESNet Communication and Network Options A B VESNET Ethernet Heartbeat VNet A VNet B Comm Active Comm Fault TELCO POWER J8 PRI SEC Line 1 Line 2 J7 D A T A VES, LLC 620 ALLENDALE ROAD, SUITE 175 KING OF PRUSSIA, PA PN: HW REV E VF1150 Media Gateway with Releasing Supports networking, remote monitoring, virtual display and remote programming and remote displays. A B VESNET Heartbeat VNet A VNet B Comm Active Comm Fault POWER J8 J7 D A T A VF1151 Network Interface Card (NIC) with Releasing Used for inter-panel networking and interfaces to other systems. VES, LLC 620 ALLENDALE ROAD, SUITE 175 KING OF PRUSSIA, PA MODEL NO.: VF NETWORK INTERFACE CARD (NIC) WITH RELEASING Heartbeat POWER J8 PN: HW REV E Ethernet VNet A VNet B Comm Active Comm Fault D A T J7 A VES, LLC 620 ALLENDALE ROAD, SUITE 175 KING OF PRUSSIA, PA MODEL NO.: VF MODEM-DACT ETHERNET WITH RELEASING TELCO PRI SEC Line 1 Line 2 PN: HW REV E VF1153 Ether/DACT Used for single panel installations. Supports remote monitoring, virtual display, and remote programming. Communications Installation One Communications Card per Panel 1 Plug-in Ribbon Cable, 2 CAT5 wired to RJ-45 VESNet connectors 2 RJ-11 Telephone Jacks 1 RS-232 cable to panel Ethernet RJ-45 on Media Gateway Powered from Panel VESNet communication is only available on the Media Gateway and NIC. Telephone jacks are only available on the Media Gateway and Ether/DACT. Standard Features Dual-line digital communicator with line seizure on Media Gateway and Modem DACT 33.6 Kbps modem for panel downloading Provides network-wide programming with remote and local management Remote programming via esp Discovery Transmits in SIA (SIA 8 and SIA 20) Digital Communications standard (300 bps) and Contact ID communication format All nodes report through a single Media Gateway to a central station and data center VESNet configurable for Class A or B networking Communication speed of 115 Kbps on VESNet and 10BaseT Ethernet interface Built-in Firewall with messaging through LAN connections always from within VESNet Maintenance message logging Virtual Panel ready with Media Gateway Built-in Web Server in the Media Gateway for displaying Virtual Panel Installation diagnostics at startup through esp Onboard Motorola 32 bit, 66 MHz RISC processor RJ-45 (Ethernet) port for LAN connection 2 RJ-45 VESNet ports for network connections using standard CAT 3,5,5e,6 cable 2 RJ-11 Telco ports for phone lines for connection to RJ-31X or RJ-38 Up to 126 Fire Nodes can be installed on VESNet Up to 2,000 feet between nodes on VESNet Installation diagnostics at startup

11 eview Serial LCD Annunciator The eview fire alarm annunciator provides a simple and convenient method of extending the controls and indications of the Elite fire alarm control panel to other locations. The large, graphic LCD display and high brightness LED indicators duplicate the indications on the Elite fire alarm control panel at up to 15 additional locations via a simple, two-wire serial data connection. VF Red VF Gray Available in Red or Gray Up to 15 annunciators can be connected to each elan or elan RS fire control panel Large 320 Character graphic display High brightness LED indications Internal Sounder Replicates all panel controls Simple, two-wire serial connection plus 24VDC Low power consumption Multi language options Connection supervised by elan fire control panel Flush Mounting Kit available (VF Red, VF Gray) ematrix Configurable Floor Plan Mimic Annunciator The ematrix system uses flexible, optic light guides to illuminate areas on a floor plan, laid over a high resolution grid. This unique system dispenses completely with wiring and enables indicators to be moved, removed or added on site without the need for any wiring. All indicators can be configured to operate upon any event type and at point, zone or group level via the powerful and intuitive esp Discovery. Available in Red or Gray Up to 504 LED s can be controlled from any elan panel Select up to 12 printed colors (not including background and building outline) Available in a range of standard enclosures to suit any applications Custom sized units can be made upon request Choice of Red, Green or Yellow LED s ematrix can easily be re-configured or upgraded on site with minimal cost and effort Special Order Item Enclosure sizes: AM2: 14.5 Wide x 12.2 High x 3.5 Deep, Max. number of LED s = 40 AM3: 14.5 Wide x 18.9 High x 4.25 Deep, Max. number of LED s = 72 AM4: 14.5 Wide x 24 High x 5 Deep, Max. number of LED s = 88

12 VF Channel Input/Output Board To add more I/O capablity to the extensive options already offered by the elan control panel, up to thirty two, sixteen channel I/O boards may be connected. When using a simple two wire RS485 communications protocol, these boards may be mounted locally to the control panel or distibuted on a bus up to 3,900 feet long by using a suitable cable. The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or and output. 16 channels Each channel configurable as input or output Inputs opto-isolated Outputs open collector transistor Simple 2 wire connection to control panel Up to 32 boards supported per panel (512 Input/Output Channels) Inputs and outputs configurable as per field devices Full cause and effects on all inputs and outputs Multi drop RS485 communications Can be used with other elan I/O modules on the same panel VF3033/ VF3034 Single Action and Dual Action Addressable Pull Station The VF3033 and VF3034 series pull stations are operated by pulling the handle marked PULL on the front of the station as far down as it will go. At that point, the station will lock in place and is easily visible from up to 50 feet. The activation handle is reset by opening the station with the key, placing the handle in the normal upright position and relocking the station. On the dual action, the push bar rotates inward allowing the PULL handle to be grasped and operated by a single hand. A VF5608 Mini Switch Monitor is an integrated component of this assembly allowing user flexibility in assigning its own unique Signaling Line Circuit (SLC) loop address. Single or Dual Action Gold Plated Alarm Contacts Surface or Weatherproof back boxes available. Status LED to indicate device operational state SLC wiring easily attached with screw compression plates

13 VF5600 Ionization Smoke Sensor Head 5 programmable response modes Drift compensation Address is set by X-Pert card and is stored in base Two Status LEDs for 360 visibility of alarm status VF5601 Photoelectric Smoke Sensor Head 5 programmable response modes Drift compensation Two Status LEDs for 360 visibility of alarm status Address is set by X-Pert card and is stored in base VF5602 Heat Detector Head 5 programmable response modes Address is set by X-Pert card and is stored in base Fixed point or rate of rise function Two Status LEDs for 360 visibility of alarm status Programmable Range (F) VF5603 Multisensor Detector Head 5 programmable response modes Combines photo smoke and heat value for enhanced detection performance and false alarm reduction Address is set by X-Pert addressing and is stored in the sensor base Rate of rise heat option Drift compensation Two Status LEDs for 360 visibility of alarm status

14 VF5632 E-Z Fit Base The E-Z fit base is a low profile 6 mounting base for detectors High degree of protection against unauthorized removal VF4990 Aux Powered Sounder Base Compatible panel silence functions Sync network self tests to ensure synchronized output if upstream sync signal is lost Sounders will operate in failsafe mode if the sync network is compromised Continuous or Temporal output with Sync module available to sync multiple temporal units VF5635 Low Power Relay Base The VF5635 Low Power Relay Base incorporates a low power relay to control field equipment such as automatic door closers Gives a set of voltage free contacts controlled by the remote output of a detector Draws negligible current VF5633 Isolating Base The VF5633 Isolating Base sense and detects short circuit faults on SLC loops Up to 20 devices may be installed between isolating bases XPERT addressing Accommodates a sensor head. VF5640 Blank XPERT Card A Universal address card supplied with all bases. Using a coding guide, pips are removed to set the address of the inserted detector. Simplifies and speed up installation and commissioning Used patented, proven technology Address remains the same, no matter how often detectors are replaced

15 VF5663 Input Module Three input states - normal, fault and alarm One visible LED Fast response time Mounts on 2-gang or 4x4 box VF5664 Dual Input Module Three input states per input - normal, fault and alarm Two visible LEDs Fast response time Mounts on 2-gang or 4x4 box 2 Individual inputs on one module. VF5665 Input/ Output Module Provides a single-pole output, supervised input and a non-supervised input Visible LED Fast response time Mounts on 2-gang or 4x4 box VF5666 Supervised Output Module Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off Can also be used for public address speakers Visible LED Can be used for remote NAC circuits or boosters. VF5667 Relay Output Module The Relay Output Module provides a single 2-pole changeover relay Can be placed anywhere on loop Visible LED

16 VF5608 Mini Input Module Designed for use where space is limited LED status indication (Yellow - Fault, Green - Polling, Red - Alarm) DIN Rail Mountable VF5660 Pigtail Input Module Three input states - normal, fault and alarm LED depicting module status condition Designed to fit into equipment with limited space Monitors equipment where a fast response is required Class A or Class B input capability VF5605 Isolator The VF5605 Isolator is placed at intervals on the loop and ensures that, in the case of a short circuit, only the section between the isolators will be affected. When the short circuit is removed, the isolators automatically restore power and data to the isolated section. Detects wiring short circuits using patented technology Minimizes disruption from short circuits Automatic de-isolation on short circuit removal Up to 20 devices may be installed between isolators VF5634 Isolator Base The VF5634 Isolator Base is unique and designed to only accept the Isolator Only accepts Isolators VF4992 Duct Smoke Detector Patent pending Test Port Valve allows for aerosol smoke testing without cover removal Clear cover fitted with four captive No-Tools Required thumbscrews In-line terminal block for easier wiring More wiring space than competitive models Built in alarm relay test switch Unit includes green pilot and red alarm visual indicators External mounting tabs do not require cover removal to install One set of 15A form C alarm contacts

17 VF VF VF VF Horns and Strobes The VES series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. Sleek modern aesthetics Finger slide switches Voltage test points Multiple voltages 3 audible settings 90, 95, 99 db 8 Candela settings: Wall - 15 / 1575 / 30 / 75 / 95 / 110 / 135 / 185 Ceiling - 15 / 30 / 60 / 75 / 95 / 115 / 150 / 177 Universal mounting base - Ceiling and wall mounts to 5 backbox types Environmentally friendly - Low current draw Compatible with UL Regulated Voltage using filtered DC or unfiltered VRMS input voltage VF071x Fire Document Enclosure Matches design and color scheme for standard Elite control panels Standard enclosure holds 50 sheets of paper, deep version holds 100 sheets Key lockable, Tamper included Designed for versatility Choice of small or large capacity enclosure in Red or Gray The Doc Box also doubles up as a Key Box, providing 7 easily accessible formed key hooks VF0710-xx* VF0711-xx* VF0712-xx* VF0713-xx* Standard Deep Standard w/tamper Deep w/tamper *xx = 10 (Red) or 40 (Gray) VF073x Ancillary Enclosure The Ancillary Enclosure is designed to provide an organized and secure mounting enclosure for I/O cards and SLC devices. The Ancillary Enclosure is manufactured in three different sizes, two different colours and with a tamper option. The Ancillary Enclosure is customized with mounting requirements and multiple conduit entries to fit module configurations depicted in the table below. A combination of SLC devices, I/O boards, din rail and PSU can be achieved. Available in Red (-10) or Gray (-40). VF0730-xx* 14.5 W x 12.2 H x 3.4 D VF0731-xx* 14.5 W x 18.9 H x 4.25 D VF0732-xx* 14.5 W x 24 H x 5 D * xx = 10 (Red) or 40 (Gray) VF VF VF VF VF VF VF VF VF VF VF VF Chassis plate part number: VF Auxiliary Enclosure Device Plate, Large Enclosure VF Auxiliary Enclosure Device Plate, Medium Enclosure VF Auxiliary Enclosure Device Plate, Small Enclosure Horn Strobe - Wall - Red Horn Strobe - Wall - White Horn Strobe - Ceiling - Red Horn Strobe - Ceiling - White Strobe - Wall - Red Strobe - Wall - White Strobe - Ceiling - Red Strobe - Ceiling - White Horn - Wall - Red Horn - Wall - White Horn - Ceiling - Red Horn - Ceiling - White

18 VoiceAlert Voice Evacuation System The VES VoiceAlert High Rise Evacuation System operates in conjunction with the elan Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The VoiceAlert system includes all necessary features to provide an effective voice evacuation system. The VoiceAlert can be custom configured to satisfy the needs of any high rise application. True Multiplex 6 Channel Distributed Audio Modular System - components added as needed Integrated 2 Channel Digital Message Repeater Live Microphone Page to any zone Fast RS-485 Communication Protocol Easy Installation and Operation Natural Sound Voice Recordings Built in Alarm and Alert Signals Up to 4 Minute Message Capacity Works with 12VDC or 24VDC Fire Alarm Panel Listed with for use with the elan FACP 3 Minute Message Restart on Microphone Key Fully Supervised VF9700 Master Panel Operation - Basic System includes Master Panel (VF9700) Master Mic Control 16 switch control points Dual Channel DMR High speed communication loop Optional Integrated Fire Phone Distributed Panel (VF9755)* 4 Output Zones (may be configured for 8) Dual Channel Audio Interface Dual Channel Amplification Maximum System Configuration Up to 256 Distributed Panels (VF9755) Up to 2028 monitor and control points VF9775 Distributed Panel Master Panels VF9720 VF9740 VF9722 VF9742 VF9724 VF9744 VF9726 VF9746 VF9728 VF9748 VF9730 VF9750 VF9751 VF Zones 16 Zones with Fire Phone 32 Zones 32 Zones with Fire Phone 48 Zones 48 Zones with Fire Phone 64 Zones 64 Zones with Fire Phone 80 Zones 80 Zones with Fire Phone 96 Zones 96 Zones with Fire Phone 112 Zones 128 Zones *Number of distributed panels to be determined by building specifications Distributed Panels - Single Channel VF Watt VF Watt with Fire Phone VF Watt VF Watt with Fire Phone VF Watt VF Watt with Fire Phone VF Watt, 16 Audio Channels with Fire Phone Distributed Panels - Dual Channel VF Watt VF Watt with Fire Phone VF Watt VF Watt with Fire Phone VF Watt, 4 Audio Channels with Fire Phone VF Watt, 16 Audio Channels with Fire Phone

19 VoiceAlert Fire Phone Equipment Fire Phone accessories give the VMX system two-way communication capability. Fire Phone jacks are mounted on a single gang plate. Fixed telephone and warden stations are available in surface/ semi-flush mount cabinet with a thumb-turn-latch. VF9512 Telephone Jack VF9511 Portable Handset Brushed Stainless Steel Single Gang Plate VF9514 Fire Phone Station Coil cord / Thumb Turn Latch Available in Red or Gray Size: Surface / Semi-Flush Mount 12-3/4 x 7-1/4 x 3-3/4 h-w-d VF9517 Warden Station Color - Red 6 mount in VF9510 cabinet Can be used with telephone jack plate (VF9512) Armored cable / Thumb Turn Latch Available in Red or Gray Size: Surface / Semi-Flush Mount 12-3/4 x 7-1/4 x 3-3/4 h-w-d VF9510 Telephone Cabinet Holds 6 VF9511 Available in Red or Gray Size: Surface / Semi-Flush Mount / Key Lock 27 x 14-1/2 x 4 h-w-d Speakers and Speaker/Strobes VES offer a comprehensive range of speakers and speaker strobes including wall mounted, ceiling mounted and vandal resistant versions. All models feature high efficiency sound output, with dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 2 watts. They are designed to provide a sleek, aesthetic appearance for emergency voice/alarm communications systems. VES speakers and speaker strobes mount to standard electrical boxes for ease of installation, they are also available as a surface mounted option. Approvals: UL, FM, MEA, CSFM, BFP ADA/NFPA/ANSI compliant Field selectable candela settings Field selectable taps for 25 or 70 VRMS operation from 1/8-2 watts High efficiency design for maximum output at minimum wattage Fast IN/OUT screw terminals Available in Red or Off White VF VF VF VF VF VF VF VF Wall Speaker 2 Watt Red Wall Speaker 2 Watt White Ceiling Mount Speaker 2 Watt Red Ceiling Mount Speaker 2 Watt White Wall Speaker/Strobe 2 Watt Red Wall Speaker/Strobe 2 Watt White Ceiling Speaker/Strobe 2 Watt Red Ceiling Speaker/Strobe 2 Watt White For a full list of units please see individual data sheets

20 FIRE DETECTION SYSTEMS VES LLC, 620 Allendale Road, King of Prussia, PA Tel: (Toll free) Fax: Web: Distributed by: Version /2010.

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description SFC-200 SERIES FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped

More information

Fire detection equipment

Fire detection equipment PRODUCT CATALOG Fire detection equipment www.apollo-fire.com Apollo Fire Detectors is one of the world s largest manufacturers of fire detectors, modules and notification devices. Established in 1980,

More information

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description INTELLIGENT FIRE ALARM CONTROL PANELS MR-2100/MR-2200 Intelligent Fire Alarm Control Panels Description MR-2100/MR-2200 Intelligent Fire Alarm Control Panel (shown with optional LED modules) Secutron's

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment

More information

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval. Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work GE Security Small Building Life Safety Solutions Affordable FireShield Conventional Fire Alarm Control Panels imagination at work cost Location: Environment: Solution: Flower shop Finely decorated, gentle

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10 TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified

More information

Alliance System Ordering Guide

Alliance System Ordering Guide Alliance System Ordering Guide Multiple Technologies Versatile Hardware Powerful Software One family of parts and accessories Version 12-Nov-03 Alliance System Ordering Guide Table of Contents Controllers

More information

Elite-RS Panel Installation Manual

Elite-RS Panel Installation Manual Elite-RS Panel Installation Manual Issue Date: 9/7/2010 Underwriters Laboratories (UL) File number (S 8485) Fire Alarm Equipment The VES Elite-RS Panel is suitable as follows: Local Signaling Unit Releasing

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

Life Alarm Fire Alarm Controls

Life Alarm Fire Alarm Controls FIRE SUPERVISORY SUPV SILENCED SILENCE AC POWER RESET UL, ULC Listed FM Approved MEA Approved* Life Alarm Fire Alarm Controls Fire Alarm Controls 4005 Series Fire Alarm Control Panels Eight through Thirty-Six

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

C. Conform to requirements of Americans with Disabilities Act (ADA).

C. Conform to requirements of Americans with Disabilities Act (ADA). SECTION 28 31 00 - FIRE ALARM AND DETECTION SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire alarm and detection systems 1.2 REFERENCES A. NFPA 70 - National Electrical Code B. NFPA 72 - National

More information

CB200W Water Leak Detection Panel Application Guide

CB200W Water Leak Detection Panel Application Guide Checked by: AJC Approved by: JBJ Contents CB200W Water Leak Detection Panel Application Guide 1. Cabinet Specifications... 2 2. Panel Hardware Specifications... 3 3. Panel Configuration... 4 4. Technical

More information

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12)

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions 800-09617V1 Rev A 11/12) UL864 (Commercial Fire) Compliance General Requirements The VISTA-128FBPT/VISTA250FBPT

More information

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,

More information

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need?

Fire Alarm FAQs. Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need? 5/2/2014 Fire Alarm FAQs Question Answer Q: How many zone/circuit fire alarm panel do I need? Q: What candela strobes do I need? A: The size of a fire alarm panel is determined by a number of factors,

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected

More information

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Alarm System Plans Review Checklist Property location Date of Review Fire Alarm System Plans Review Checklist Property location Date of Review 1. Is application completed in entirety? 2. Are the plans review fee submitted with the application? 3. Does floor plan include

More information

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0

More information

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems

More information

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL NOT YOUR STANDARD FIRE ALARM PANEL FLEXIBILITY, SPEED, INTELLIGENCE CyberCat the digital, peer-to-peer bi-directional, communication system that

More information

PLAN REVIEW GUIDE FOR FIRE ALARM

PLAN REVIEW GUIDE FOR FIRE ALARM PLAN REVIEW GUIDE FOR FIRE ALARM PROJECT NAME: PERMIT # PROJECT ADDRESS: CONTACT PERSON: PHONE Fire alarm system installation information shall be provided on the appropriate architectural and electrical

More information

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19 TECHNICAL SPECIFICATIONS Page 1 of 19 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC analogue addressable, electrically supervised, zone annunciated, fire detection and alarm system as

More information

SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM

SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM SECTION 13850 (28 31 00) FIRE DETECTION AND ALARM SYSTEM ENGINEERING SPECIFICATION INTELLIGENT REPORTING FIRE DETECTION SYSTEM PART 1 GENERAL 1.1 DESCRIPTION A. This specification includes the furnishing,

More information

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual P/N 315-049403-1 Siemens Building Technologies Fire Safety Table Of Contents Introduction...1 The Access levels...1 User Level...1 Maintenance

More information

EDWARDS SIGNAL SOLUTIONS www.edwards-signals.com DISTRIBUTED BY: Lee Dan Communications, Inc. www.leedan.com info@leedan.com Toll-Free: 800-231-1414

EDWARDS SIGNAL SOLUTIONS www.edwards-signals.com DISTRIBUTED BY: Lee Dan Communications, Inc. www.leedan.com info@leedan.com Toll-Free: 800-231-1414 EDWARDS SIGNAL SOLUTIONS www.edwards-signals.com DISTRIBUTED BY: Lee Dan Communications, Inc. www.leedan.com info@leedan.com Toll-Free: 800-231-1414 Fire Alarm CONTROL S y s t e m s CONVENTIONAL FIRE ALARM

More information

DTW Works Master Specification Version 2006

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section 13852 Multiplex Fire Alarm System Page 1 of 10 PART 1 GENERAL 1.1 RELATED WORK.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Procedures..3 Section 01810 Commissioning..4

More information

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs Building Solutions One Honeywell Solution for All of Your Fire Systems Needs Intelligent and Accurate Detection Fire/CO The Advanced Multi-Criteria Fire/CO is a plug-in, addressable device that provides

More information

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM

SECTION 16721 FIRE ALARM AND DETECTION SYSTEM 1. GENERAL 1.1. Related Documents: 1.2. Scope: 1.1.1. The general provisions of the Contract, including General and Supplementary Conditions and General Requirements apply to the work specified in this

More information

Life Safety Innovation Delivering energy-efficient & intelligible notification solutions

Life Safety Innovation Delivering energy-efficient & intelligible notification solutions Life Safety Innovation Delivering energy-efficient & intelligible notification solutions Notification Cooper Notification Life Safety is our Business Wheelock LED Horn Strobes, Strobes and Horns TM Lowest

More information

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals INFINITY The Intelligent 2 Wire Fire Detection System for Professionals Infinity ID 2 The intelligent 2 wire fire detection system for professionals In a nutshell Zeta Alarm Systems is proud to introduce

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

Intelligent Fire Detection & Alarm and Mass Notification System. www.mircom.com/flex-net

Intelligent Fire Detection & Alarm and Mass Notification System. www.mircom.com/flex-net Intelligent Fire Detection & Alarm and Mass Notification System www.mircom.com/flex-net The Most Versatile and Powerful Systems in the Industry FleX-Net is a next generation modular network system that

More information

SILENT KNIGHT MODEL 5207

SILENT KNIGHT MODEL 5207 SILENT KNIGHT MODEL 5207 Fire Control / Communicator Installation, Programming, and Operation Manual Part Number 150865 Rev. C, 04/03 Contents Section 1 Introduction.......................................................................1-1

More information

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000

More information

University Design Standard. Fire Alarm Systems

University Design Standard. Fire Alarm Systems University Design Standard Fire Alarm Systems 1.0 Overview This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit

More information

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS

SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat

More information

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog.

TELEPHONES Accessories. Phones. parts. Keypad Telephones Auto Dial. Courtesy Inmate Telephones. Hands-Free Telephone. Catalog. Telephones &Accessories Catalog parts Emergency Phones 2015 Hands-Free Telephone Keypad Telephones Auto Dial TELEPHONES Accessories Courtesy Inmate Telephones www.parabit.com revised as of 05.22.14 Keypad

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are

More information

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING: New Zealand made multi purpose plumbing control for Prison cells Vandal resistant controls Water saving fittings DESCRIPTION Warden 4 is a multi purpose

More information

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

Controller 5000GL Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. GGBUS L LOCAL BUS

More information

Faraday Intelligent Fire Detection Systems

Faraday Intelligent Fire Detection Systems Faraday Intelligent Fire Detection Systems Faster detection means better protection for buildings and the people in them. Greater safety and value for new and retrofit applications The right fit Fire safety

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

Conventional Fire Detection and Extinguishant Control System Specification

Conventional Fire Detection and Extinguishant Control System Specification Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release

More information

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen) Safely into a new day Advanced modular FIRE ALARM CONTROL PANEL with additional functionality NJP-400A NJP-401A I m on FIRE (Bruce Springsteen) EN 54-2, EN 54-4 Cert No. 1124a DESCRIPTION OP-400A, NJP-400A,

More information

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM PART 1.0 - GENERAL 1.1 DESCRIPTION: A. This section of the specifications includes the furnishing, installation, and connection of a multiprocessor controlled,

More information

Dialog Telephone Interface Module Installation Sheet

Dialog Telephone Interface Module Installation Sheet Dialog Telephone Interface Module Installation Sheet Description The Dialog Telephone Module (DTIM), model number 60-879- 95R, is a battery operated communication link between the security system control

More information

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM

SECTION 28 31 11 FIRE ALARM AND DETECTION SYSTEM KNOXVILLE, TENNESSEE SECTION 28 31 11 PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK SECTION 28 31 11 A. Extent of fire alarm and detection system work shall be as described in this specification, as

More information

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000 I. General A. Summary The monitoring system shall be an expandable, self-contained microprocessor-controlled IMS-4000 Host unit (hereafter referred to as

More information

Emergency voice communications Product Name

Emergency voice communications Product Name Product Name 76 EATON FIRE AND VOICE ALARM SYSTEMS CFCC2556 January 2015 Contents Contents Emergency voice communications Panels Network exchange units 78 Non network exchange units 80 Devices Outstations

More information

VEGA Analogue Addressable Control Panels

VEGA Analogue Addressable Control Panels Analogue Addressable Control Panels Representing the future of fire alarm control technology, Vega's modular concept enables the tailoring of system design for the smallest to the largest system. Designed

More information

Versatile. EST3X Life Safety Solutions. An EDWARDS brand.

Versatile. EST3X Life Safety Solutions. An EDWARDS brand. Versatile EST3X Life Safety Solutions See what s possible now. An EDWARDS brand. It does. EST3X does more than provide life safety protection. It provides a bridge between what s needed and what can be

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

D287/D288/D292/D293A/D293E

D287/D288/D292/D293A/D293E D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization

More information

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS

APPLICATION NOTE. The DMP Software Family DMP COMPUTER SOFTWARE PROGRAMS APPLICATION NOTE Contents The DMP Software Family... 1 Stand-Alone Link Software... 1 Add-on Modules for Link Software... 1 System Link End-User Panel Management Software... 2 Simple Registration and Activation...

More information

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION SECTION 16721 FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION A. This section of the specifications includes the furnishing, installation, and connection of the microprocessor-controlled

More information

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring. MediaLink IP Intercom System Two-way voice communications over an IP network Integrated microphone, speaker, and call buttons Flexible paging capabilities Classroom intercom system for two-way voice communications,

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

CATALOG NUMBER. Features. Description

CATALOG NUMBER. Features. Description VOICE EVACUATION SYSTEM QX000 SERIES Description Mircom s QX000 Series is a multichannel zoned audio system that allows the operator to selectively page from a central location to any of the system s audible

More information

Office of Integrated Security Systems Longwood University Camera System Standards

Office of Integrated Security Systems Longwood University Camera System Standards Office of Integrated Security Systems Longwood University Camera System Standards 1 GENERAL A. All equipment and materials used shall be standard components that are regularly manufactured and used in

More information

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM-10-011 Fire Alarm System plan(s) MUST be reviewed and approved by the Belmont Fire Department prior to the start of construction. The design and any changes must be fully compliant with NFPA 1, NFPA 101, NFPA

More information

Product Specification instalert Rapid Messenger Variable Message Sign

Product Specification instalert Rapid Messenger Variable Message Sign instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

IP Intercom System www.extron.com

IP Intercom System www.extron.com MediaLink IP Intercom System Two-way voice communications over an IP network Integrated microphone, speaker, and call buttons Flexible paging capabilities Classroom intercom system for two-way voice communications,

More information

Always on the Lookout Perfect Protection against Burglary

Always on the Lookout Perfect Protection against Burglary Always on the Lookout Perfect Protection against Burglary Terxon wired and hybrid alarm systems One system offers all possibilities Rely on experts With a qualified specialist installation contractor on

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

HLWLAN 802.11b/g/n Transceiver Kit

HLWLAN 802.11b/g/n Transceiver Kit 092524 RevB HLWLAN 802.11b/g/n Transceiver Kit Wireless Communications for OmniLogic Owner s Manual Contents Introduction...1 Installation...2 Configuration...6 Operation...8 Troubleshooting...9 HLWLAN

More information

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording Hardware & Installation Guide Algo Communication Products Ltd. Customer Support and Sales Tel: 1.877.884.2546 Fax: 604.437.5726 Email: sales@algosolutions.com support@algosolutions.com www.algosolutions.com

More information

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM Intelligent Fire Alarm & Emergency Communications Network MMX-LOC MMX-BBX-FXMNS Description Secutron s MMX TM Series Mass Notification System (MNS) is designed

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S7010 7165-1477:111 INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM BBX-FXMNSR Description BBX-5014R Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications.

More information

Process Alarm Solutions

Process Alarm Solutions Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical

More information

Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n

Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n Keyscan Hosted Services A C e n t r a l l y M a n a g e d A c c e s s C o n t r o l S o l u t i o n A convenient, new way Since the launch of Keyscan s Centrally Managed Access Control (CMAC), access control

More information

466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide

466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: 60-883-95R. CareGard. User Guide ) *(6HFXULW\ 466-1936 Rev E October 2004 ZZZ*(6HFXULW\FRP Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by GE Security

More information

Fire Fighter Phone System Installation Instructions

Fire Fighter Phone System Installation Instructions Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).

More information

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control

More information

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training)

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training) TX3 Series TELEPHONE/CARD ACCESS SYSTEMS System Introduction (Sales Training) The new TX3 is designed to provide the best performance and value in stand alone or fully integrated system configurations:

More information

T1 Backhaul Connectivity Solution All Products :: Application Note

T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments

More information

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE You can program online 24/7 giving you the freedom to work when and where you want. From remote bookkeeping and access, to security control on the ground

More information

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS PROPERTY ADDRESS (BRT Address Required) TESTING CONTRACTOR (Name and Address) License No. ANNUAL

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

HyperAccess Access Control System

HyperAccess Access Control System Control System We manufacture, an advanced PC based access control solution that will give you control over who has access to your building. With you can control access on hundreds of doors for up to 10,000

More information

How To Use A Fortivoice Phone On A Cell Phone On An Ipad Or Ipad (For A Sim Sim) On A Simplon (For An Ipod) On An Iphone Or Ipod (For Ipad)

How To Use A Fortivoice Phone On A Cell Phone On An Ipad Or Ipad (For A Sim Sim) On A Simplon (For An Ipod) On An Iphone Or Ipod (For Ipad) FortiFone QuickStart Guide for FON-260i FortiFone QuickStart Guide for FON-260i Revision 3 27-400-195511-20130729 Copyright 2013 Fortinet, Inc. All rights reserved. Fortinet, FortiGate, and FortiGuard,

More information

IP Box Camera ACM-5711. Ver. 081016. Hardware User s Manual

IP Box Camera ACM-5711. Ver. 081016. Hardware User s Manual IP Box Camera ACM-5711 Ver. 081016 Hardware User s Manual 0 0 PRECAUTIONS 1. Read these instructions All the safety and operating instructions should be read before the product is operated. 2. Heed all

More information