Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Size: px
Start display at page:

Download "Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:"

Transcription

1 CPU 314C-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the CPU in encrypted form by means of S7-Block Privacy to protect the know-how of the application. Diagnostics buffer; the last 500 error and interrupt events are stored in a buffer for diagnostic purposes. Of these, the last 100 entries are retentive. Maintenance-free data backup; the CPU automatically saves all data (up to 64 KB) in case of a power failure so that the data are available again unchanged when the power returns. Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7: General: Definition of the name, plant designation and location designation. Startup; definition of the startup characteristics of the CPU and the monitoring time Synchronous cycle interrupts; setting of IO system number, process image partition number, and delay time Page 1400 Mar 2008 Siemens ITS

2 Cycle/clock memory; specification of the maximum cycle time and load. Setting of the clock memory address. Retentivity; definition of the number of retentive bit memories, counters, timers and data blocks Clock interrupts; setting the start date, start time and periodicity Watchdog interrupts; setting of periodicity System diagnostics; determining handling and scope of the diagnostic alarms Clock;setting the type of synchronization in the AS or on the MPI Protection level; specifying the access rights to program and data Communication; reservation of connection resources Web; settings for the Web server of the CPU MPI/PROFIBUS DP interface; setting the interface type. Determining node addresses. Parameterizing the operating mode and configuring the transfer areas in the case of PROFIBUS DP. Parameterizing the time synchronization PROFINET interface; setting the addresses. Parameterizing the PROFINET properties, the I-Device functionality, the type of synchronization on PROFINET, the time synchronization using NTP procedure, the media redundancy, and the KeepAlive function. Assigning parameters to Port 1 and Port 2. Digital inputs/outputs; setting of addresses, input delay and process interrupt Analog inputs/outputs; setting of addresses; Page 1401 Mar 2008 Siemens ITS

3 in the case of inputs: Setting the temperature unit, the measurement type, the measuring range, and the interference frequency; in the case of outputs: Setting the output type and output range Integrated function "counting"; setting the addresses, parameter assignment of the modes "continuous counting", "single counting", "periodic counting", "frequency measurement" and "pulse width modulation" Integrated function "positioning"; setting of addresses, parameterizing of "positioning with digital outputs" and "positioning with analog outputs" Integrated "Rules" function Display and information functions Status and error indications; LEDs indicate hardware, programming, time or I/O errors, for example, and operating statuses such as RUN, STOP and start-up. Test functions; the PG is used to indicate signal states during program execution, to modify process variables independently of the user program and to output the contents of stack memories. Information functions; you can use the PG to obtain information about the storage capacity and operating mode of the CPU as well as the current loading of the main and load memories as well as current cycle times and diagnostic buffer contents in plain text. Page 1402 Mar 2008 Siemens ITS

4 Integrated communication functions PG/OP communication Global data communication S7 basic communication S7 communication Routing Data record routing PROFIBUS DP master/slave Open communication over TCP/IP, ISO-on-TCP and UDP PROFINET IO Controller PROFINET I-Device PROFINET CBA Web server Page 1403 Mar 2008 Siemens ITS

5 Integrated functions Counters; 4 counters (up to 60 KHz) with direction-dependent comparators, and for direct connection of 24V incremental encoders 4 channels for frequency measurement; frequency measurement (up to max. 60 khz) enables, for example, speed measurement of a shaft with speed range monitoring or throughput measuring (parts per measuring time) with range monitoring. Period measurement; the period duration of the counting signal can be measured up to a counting frequency of 1 khz Pulse width modulation; 4 outputs for direct control of valves, final controlling elements, switching devices, heating equipment, etc., switching frequency 2.5 khz. The period length can be set and the pulse-pause ratio can be changed while running. Controlled positioning; an SFB integrated into the operating system enables an axis to be positioned via 2 digital outputs or one analog output. Alarm inputs (all digital inputs); the alarm inputs enable the detection of process events as well as the rapid triggering of responses. Technical specifications Page 1404 Mar 2008 Siemens ITS

6 Technical specifications 6ES EH04-0AB0 Product version Hardware product version 01 Firmware version V3.3 General information associated programming package STEP7 V5.5 or higher with HSP191 Supply voltage 24 V DC Input current Current consumption (rated value) 850 ma Current consumption (in no-load operation), 190 ma typ. Inrush current, typ. 5 A I²t 0.7 A² s from supply voltage L+, max. 850 ma Power losses Power loss, typ. 14 W Memory Work memory Page 1405 Mar 2008 Siemens ITS

7 integrated 192 Kibyte expandable No Size of retentive memory for retentive data 64 Kibyte blocks Load memory pluggable (MMC) pluggable (MMC), max. 8 Mbyte Data management on MMC (after last 10 a programming), min. Backup present ; Guaranteed by MMC (maintenancefree) without battery ; Program and data CPU-blocks Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. DB Number, max ; Number range: 1 to Size, max. 64 Kibyte FB Number, max ; Number range: 0 to 7999 Size, max. 64 Kibyte FC Page 1406 Mar 2008 Siemens ITS

8 Number, max ; Number range: 0 to 7999 Size, max. 64 Kibyte OB Size, max. 64 Kibyte Nesting depth per priority class 16 additional within an error OB 4 CPU processing times for bit operations, min µs for word operations, min µs for fixed point arithmetic, min µs for floating point arithmetic, min µs Counters, timers and their retentivity S7 counter Number 256 Retentivity adjustable 0 lower limit 255 upper limit Z 0 to Z 7 preset Page 1407 Mar 2008 Siemens ITS

9 Counting range adjustable 0 lower limit 999 upper limit IEC counter present Type SFB Number Unlimited (limited only by RAM capacity) S7 times Number 256 Retentivity adjustable 0 lower limit 255 upper limit No retentivity preset Time range 10 ms Page 1408 Mar 2008 Siemens ITS

10 lower limit s upper limit IEC timer present Type SFB Number Unlimited (limited only by RAM capacity) Data areas and their retentivity retentive data area, total All, max. 64 KB Flag Number, max. 256 byte Retentivity available ; MB 0 to MB 255 Retentivity preset MB 0 to MB 15 Number of clock memories 8; 1 memory byte Data blocks Retentivity adjustable ; via non-retain property on DB Retentivity preset Local data per priority class, max. 32 Kibyte; Max bytes per block Address area I/O address area Inputs byte Outputs byte of which, distributed Page 1409 Mar 2008 Siemens ITS

11 Inputs Outputs Process image Inputs, adjustable Outputs, adjustable Inputs, default Outputs, default Default addresses of the integrated channels Digital inputs Digital outputs Analog inputs Analog outputs Subprocess images Number of subprocess images, max. Digital channels integrated channels (DI) byte byte byte byte 256 byte 256 byte to to to to 803 1; With PROFINET IO, the length of the user data is limited to 1600 bytes Page 1410 Mar 2008 Siemens ITS

12 integrated channels (DO) 16 Inputs Outputs Inputs, of which central Outputs, of which central Analog channels Integrated channels (AI) 5; 4 x current/voltage, 1 x resistance Integrated channels (AO) 2 Inputs Outputs Inputs, of which central 253 Outputs, of which central 250 Hardware configuration Racks, max. 4 Modules per rack, max. 8; In rack 3 max. 7 Expansion devices, max. 3 Number of DP masters integrated 1 via CP 4 Number of operable FMs and CPs (recommended) FM 8 CP, point-to-point 8 Page 1411 Mar 2008 Siemens ITS

13 CP, LAN 10 Time of day Clock Hardware clock (real-time clock) battery-backed and synchronizable Deviation per day, max. 10 s; Typ.: 2 s Backup time 6 wk; At 40 C ambient temperature Behavior of the clock following POWER- Clock continues running after POWER OFF ON Behavior of the clock following expiry of Clock continues to run with the time at backup period which the power failure occurred Operating hours counter Number 1 Number/Number range 0 Range of values 0 to 2^31 hours (when using SFC 101) Granularity 1 hour retentive ; Must be restarted at each restart Clock synchronization supported to MPI, master to MPI, slave to DP, master ; With DP slave only slave clock to DP, slave in AS, master Page 1412 Mar 2008 Siemens ITS

14 in AS, slave on Ethernet via NTP ; as client Digital inputs Number/binary inputs 24 of which, inputs usable for technological 16 functions Input characteristic curve acc. to IEC 1131, Type 1 Number of simultaneously controllable inputs horizontal installation 24 up to 40 C, max. 12 up to 60 C, max. vertical installation 12 up to 40 C, max. Technological functions 50 m; at maximum count frequency shielded, max. not allowed Unshielded, max. Standard DI Page 1413 Mar 2008 Siemens ITS

15 shielded, max. Unshielded, max. Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs Parameterizable Rated value for counter/technological functions at "0" to "1", max m 600 m 24 V -3 to +5 V 15 to 30 V 8 ma ; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.) 3 ms 8 µs; Minimum pulse width/minimum pause between pulses at maximum counting Page 1414 Mar 2008 Siemens ITS

16 frequency Cable length Cable length, shielded, max m; 50 m for technological functions Cable length unshielded, max. 600 m; For technological functions: No Digital outputs Number/binary outputs 16 of which high-speed outputs 4; Notice: You cannot connect the fast outputs of your CPU in parallel Functionality/short-circuit strength ; Clocked electronically Response threshold, typ. 1 A Limitation of inductive shutdown voltage tol+ (-48 V) Lamp load, max. 5 W Controlling a digital input Output voltage for signal "1", min. L+ (-0.8 V) Output current for signal "1" rated value 500 ma for signal "1" permissible range, min. 5 ma for signal "1" permissible range, max. 0.6 A for signal "1" minimum load current 5 ma for signal "0" residual current, max. 0.5 ma Parallel switching of 2 outputs for increased power No for redundant control of a load Page 1415 Mar 2008 Siemens ITS

17 Switching frequency with resistive load, max. with inductive load, max. on lamp load, max. of the pulse outputs, with resistive load, max. Aggregate current of outputs (per group) horizontal installation up to 40 C, max. up to 60 C, max. vertical installation up to 40 C, max. Load resistance range lower limit upper limit Cable length Cable length, shielded, max. Cable length unshielded, max. Analog inputs Number of analog inputs for voltage/current measurement 100 Hz 0.5 Hz 100 Hz 2.5 khz 3 A 2 A 2 A 48 Ω 4 kω m 600 m 4 Page 1416 Mar 2008 Siemens ITS

18 Number of analog inputs for 1 resistance/temperature measurement permissible input frequency for current 5 V; Permanent input (destruction limit), max. permissible input voltage for voltage input 30 V; Permanent (destruction limit), max. permissible input current for voltage input 0.5 ma; Permanent (destruction limit), max. permissible input current for current input 50 ma; Permanent (destruction limit), max. Technical unit for temperature measurement; Degrees Celsius / degrees Fahrenheit / adjustable Kelvin Input ranges Voltage ; ±10 V / 100 kω; 0 V to 10 V / 100 kω Current ; ±20 ma / 100 Ω; 0 ma to 20 ma / 100 Ω; 4 ma to 20 ma / 100 Ω Resistance thermometer ; Pt 100 / 10 MΩ Resistance ; 0 Ω to 600 Ω / 10 MΩ Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) 100 kω Input ranges (rated values), currents 0 to 20 ma Page 1417 Mar 2008 Siemens ITS

19 Input resistance (0 to 20 ma) 100 Ω -20 to +20 ma Input resistance (-20 to +20 ma) 100 Ω 4 to 20 ma Input resistance (4 to 20 ma) 100 Ω Input ranges (rated values), resistance thermometers Pt 100 Input resistance (Pt 100) 10 MΩ Input ranges (rated values), resistors No-Load voltage, typ. 3.3 V Measured current, typ ma 0 to 600 ohms Input resistance (0 to 600 ohms) 10 MΩ Resistance thermometer (RTD) Characteristic linearization Pt 100 for resistance thermometer Characteristic linearization Parameterizable ; by software Temperature compensation Parameterizable No Cable length Cable length, shielded, max. 100 m Page 1418 Mar 2008 Siemens ITS

20 Analog outputs Number of analog outputs 2 Cable length, shielded, max. 200 m Voltage output, short-circuit protection Voltage output, short-circuit current, max. 55 ma Current output, no-load voltage, max. 14 V Output ranges, voltage 0 to 10 V -10 to +10 V Output ranges, current 0 to 20 ma -20 to +20 ma 4 to 20 ma Connection of actuators for voltage output 2-conductor connection ; Without compensation of the line resistances for voltage output 4-conductor connection No for current output 2-conductor connection Load impedance (in rated range of output) with voltage outputs, min. 1 kω with voltage outputs, capacitive load, max. 0.1 µf with current outputs, max. 300 Ω with current outputs, inductive load, max. 0.1 mh Destruction limits against externally applied Page 1419 Mar 2008 Siemens ITS

21 voltages and currents Voltages at the outputs towards MANA Current, max. Analog value creation Measurement principle Integrations and conversion time/ resolution per channel Resolution with overrange (bit including sign), max. Integration time, parameterizable permissible input frequency, max. Interference voltage suppression for interference frequency f1 in Hz Conversion time (per channel) Time constant of the input filter Basic execution time of the module (all channels released) Settling time for resistive load for capacitive load for inductive load Encoder Connection of signal encoders 16 V; Permanent 50 ma; Permanent Actual value encryption (successive approximation) 12 bit ; 16.6 / 20 ms 400 Hz 60 / 50 Hz 1 ms 0.38 ms 1 ms 0.6 ms 1 ms 0.5 ms Page 1420 Mar 2008 Siemens ITS

22 for voltage measurement for current measurement as 2-wire ; with external supply transducer for current measurement as 4-wire transducer for resistance measurement with 2- ; Without compensation of the line conductor connection resistances for resistance measurement with 3- No conductor connection for resistance measurement with 4- No conductor connection Connectable encoders 2-wire BEROS 1.5 ma permissible quiescent current (2- wire BEROS), max. Errors/accuracies Temperature error (relative to input area) +/- 0,006 %/K Crosstalk between the inputs, min. 60 db Repeat accuracy in settled status at 25 +/- 0,06 % C (relative to input area) Output ripple (based on output area, +/- 0,1 % bandwidth 0 to 50 khz) Linearity error (relative to output area) +/- 0,15 % Page 1421 Mar 2008 Siemens ITS

23 Temperature error (relative to output +/- 0,01 %/K area) Crosstalk between the outputs, min. 60 db Repeat accuracy in settled status at 25 +/- 0,06 % C (relative to output area) Operational limit in overall temperature range Voltage, relative to input area +/- 1 % Current, relative to input area +/- 1 % Impedance, relative to input area +/- 1 % Voltage, relative to output area +/- 1 % Current, relative to output area +/- 1 % Basic error limit (operational limit at 25 C) Voltage, relative to input area +/- 0,8 %; Linearity error +/ % Current, relative to input area +/- 0,8 %; Linearity error +/ % Impedance, relative to input area +/- 0,8 %; Linearity error +/- 0.2% Resistance-type thermometer, relative to +/- 0,8 % input area Voltage, relative to output area +/- 0,8 % Current, relative to output area +/- 0,8 % Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency Series mode interference (peak value of 30 db Page 1422 Mar 2008 Siemens ITS

24 interference < rated value of input range), min. Common mode interference, min. 40 db Interfaces Number of USB interfaces 0 1st interface Type of interface Integrated RS 485 interface Physics RS 485 Isolated Power supply to interface (15 to 30 V 200 ma DC), max. Functionality MPI DP master DP slave Point-to-point connection No MPI Services PG/OP communication Routing Global data communication Page 1423 Mar 2008 Siemens ITS

25 S7 basic communication S7 communication S7 communication, as client S7 communication, as server Transmission rate, max. DP master Services PG/OP communication Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Page 1424 Mar 2008 Siemens ITS No; (but via CP and loadable FBs) 12 Mbit/s No ; (I blocks only) No

26 Equidistance mode support No Isochronous mode SYNC/FREEZE Activation/deactivation of DP slaves 8 Number of DP slaves that can be simultaneously activated/deactivated, max. ; As subscriber Direct data exchange (slave-toslave communication) DPV1 Transmission rate, max. 12 Mbit/s Number of DP slaves, max. 124 Address area 2 Kibyte Inputs, max. 2 Kibyte Outputs, max. Page 1425 Mar 2008 Siemens ITS

27 User data per DP slave Inputs, max. Outputs, max. DP slave Services PG/OP communication Global data communication S7 basic communication S7 communication S7 communication, as client S7 communication, as server Direct data exchange (slave-to-slave communication) DPV1 244 byte 244 byte No No No ; Connection configured on one side only No Page 1426 Mar 2008 Siemens ITS

28 Transmission rate, max. 12 Mbit/s Automatic baud rate search ; only with passive interface Transfer memory 244 byte Inputs 244 byte Outputs Address area, max. 32 User data per address area, max. 32 byte 2nd interface Type of interface PROFINET Physics Ethernet RJ45 Isolated Integrated switch Number of ports 2 Automatic detection of transmission speed ; 10/100 Mbit/s Autonegotiation Autocrossing Media redundancy supported Switchover time on line break, typically 200 ms; PROFINET MRP Number of stations in the ring, max. 50 Change of IP address at runtime, supported Functionality Page 1427 Mar 2008 Siemens ITS

29 MPI DP master DP slave PROFINET IO Controller PROFINET IO Device PROFINET CBA PROFINET IO Controller Services No No No ; Also simultaneously with IO-Device functionality ; Also simultaneously with IO Controller functionality PG/OP communication ; With loadable FBs, max. configurable S7 communication connections: 10, max. number of instances: 32 ; OB 61 Isochronous mode ; Via TCP/IP, ISO on TCP, and UDP Open IE communication Transmission rate, max. 100 Mbit/s Number of connectable IO devices, max. 128 Max. number of connectable IO devices 128 for RT 128 Page 1428 Mar 2008 Siemens ITS

30 of which in line, max. Number of IO devices with IRT and the option "high flexibility" of which in line, max. Number of IO Devices with IRT and the option "high performance", max. of which in line, max. IRT, supported Shared device, supported Prioritized startup supported Number of IO Devices, max. Activation/deactivation of IO Devices Number of IO Devices that can be simultaneously activated/deactivated, max. IO Devices changing during operation (partner ports), supported Max. number of IO devices per tool Device replacement without swap medium Page 1429 Mar 2008 Siemens ITS

31 Send cycles Updating time Address area Inputs, max. Outputs, max. User data per address area, max. User data consistency, max. PROFINET IO Device Services PG/OP communication S7 communication Isochronous mode 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option) 250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details) 2 Kibyte 2 Kibyte byte ; With loadable FBs, max. configurable connections: 10, max. number of instances: 32 No Page 1430 Mar 2008 Siemens ITS

32 Open IE communication IRT, supported PROFIenergy, supported Shared device, supported Number of IO controllers with shared device, max. Transfer memory Inputs, max. Outputs, max. Submodules Number, max. User data per submodule, max. Open IE communication Open IE communication, supported ; Via TCP/IP, ISO on TCP, and UDP ; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I- Device byte; Per IO Controller with shared device byte; Per IO Controller with shared device byte Page 1431 Mar 2008 Siemens ITS

33 Number of connections, max. 8 Local port numbers used at the system end0, 20, 21, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, Keep-alive function, supported Communication functions PG/OP communication Data record routing Global data communication supported Number of GD loops, max. 8 Number of GD packets, max. 8 Number of GD packets, transmitter, max. 8 Number of GD packets, receiver, max. 8 Size of GD packets, max. 22 byte Size of GD packet (of which consistent), 22 byte max. S7 basic communication supported User data per job, max. User data per job (of which consistent), max. S7 communication 76 byte 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) Page 1432 Mar 2008 Siemens ITS

34 supported as server as client ; via integrated PROFINET interface and loadable FB or via CP and loadable FB User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) S5-compatible communication supported ; via CP and loadable FC Open IE communication TCP/IP ; via integrated PROFINET interface and loadable FBs 8 Number of connections, max byte Data length for connection type 01H, max byte Data length for connection type 11H, max. Several passive connections per port, supported ISO-on-TCP (RFC1006) ; via integrated PROFINET interface and Page 1433 Mar 2008 Siemens ITS

35 loadable FBs 8 Number of connections, max byte Data length, max. UDP ; via integrated PROFINET interface and loadable FBs 8 Number of connections, max byte Data length, max. Web server supported Number of HTTP clients 5 User-defined websites PROFINET CBA (at set setpoint communication load) Setpoint for the CPU communication load 50 % Number of remote interconnection partners 32 Number of functions, master/slave 30 Total of all Master/Slave connections Data length of all incoming connections byte master/slave, max. Data Page length 1434 of all outgoing connectionsmar byte Siemens ITS

36 master/slave, max. Number of device-internal and PROFIBUS 500 interconnections Data length of device-internal und byte PROFIBUS interconnections, max. Data length per connection, max byte Remote interconnections with acyclic transmission 500 ms Sampling frequency: Sampling time, min. 100 Number of incoming interconnections 100 Number of outgoing interconnections byte Data length of all incoming interconnections, max byte Data length of all outgoing interconnections, max byte Data length per connection, max. Page 1435 Mar 2008 Siemens ITS

37 Remote interconnections with cyclic transmission 10 ms Transmission frequency: Transmission interval, min. 200 Number of incoming interconnections 200 Number of outgoing interconnections byte Data length of all incoming interconnections, max byte Data length of all outgoing interconnections, max. 450 byte Data length per connection, max. HMI variables via PROFINET (acyclic) 3; 2x PN OPC/1x imap Number of stations that can log on for HMI variables (PN OPC/iMap) 500 ms HMI variable updating Page 1436 Mar 2008 Siemens ITS

38 Number of HMI variables Data length of all HMI variables, max. PROFIBUS proxy functionality supported Number of linked PROFIBUS devices byte 240 byte; Slave-dependent Data length per connection, max. Number of connections Max. total number of instances 32 usable for routing S7 message functions Number of login stations for message functions, max. Process diagnostic messages simultaneously active Alarm-S blocks, max X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. 12; Depending on the configured connections for PG/OP and S7 basic communication Page 1437 Mar 2008 Siemens ITS

39 Test commissioning functions Status/control Status/control variable Variables Number of variables, max. 30 of which status variables, max. 30 of which control variables, max. 14 Forcing Inputs, outputs, memory bits, DB, times, counters Forcing Force, variables Inputs, outputs Number of variables, max. 10 Status block ; Up to 2 simultaneously Single step Number of breakpoints 4 Diagnostic buffer present Number of entries, max. 500 No adjustable 100; Only the last 100 entries are retained Of which powerfail-proof Number of entries readable in RUN, max. 499 ; From 10 to 499 Page 1438 Mar 2008 Siemens ITS

40 adjustable preset Integrated Functions Number of counters Counter frequency (counter) max. Frequency measurement Number of frequency meters controlled positioning Integrated function blocks (closed-loop control) PID controller Number of pulse outputs Limit frequency (pulse) Isochronous mode Isochronous mode Galvanic isolation Galvanic isolation digital inputs Galvanic isolation digital inputs between the channels between the channels and the backplane bus 10 4; See "Technological Functions" manual 60 khz 4; up to 60 khz (see "Technological Functions" manual) ; PID controller (see "Technological Functions" manual) 4; Pulse width modulation up to 2.5 khz (see "Technological Functions" Manual) 2.5 khz ; For PROFINET only No Page 1439 Mar 2008 Siemens ITS

41 Galvanic isolation digital outputs Galvanic isolation digital outputs between the channels between the channels, in groups of 8 between the channels and the backplane bus Galvanic isolation analog inputs Galvanic isolation analog inputs ; common for analog I/O between the channels No between the channels and the backplane bus Galvanic isolation analog outputs Galvanic isolation analog outputs ; common for analog I/O between the channels No between the channels and the backplane bus Permissible potential difference between different circuits 75 VDC / 60 VAC between inputs and MANA (UCM) 8.0 V DC between MANA and M internally (UISO) 75 VDC / 60 VAC Isolation Isolation checked with 600 V DC Ambient conditions Operating temperature Page 1440 Mar 2008 Siemens ITS

42 Min. 0 C max. 60 C Configuration programming Programming language LAD FBD STL SCL CFC GRAPH HiGraph Command set see instruction list Nesting levels 8 Know-how protection User program protection/password protection Page 1441 Mar 2008 Siemens ITS

CPU 319-3 PN/DP. Function

CPU 319-3 PN/DP. Function CPU 319-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7313-5BF03-0AB0 Page 1 Product data sheet 6ES7313-5BF03-0AB0 SIMATIC S7-300, CPU 313C, COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO 1 PT100, 3 FAST COUNTERS (30 KHZ), INTEGRATED 24V DC POWER SUPPLY,

More information

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

6ES7314-6CG03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A 6ES7314-6CG03-0AB0 Page 1 Product data sheet 6ES7314-6CG03-0AB0 SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED

More information

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2

SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2 6ES7315-2AG10-0AB0 Page 1 Product data sheet 6ES7315-2AG10-0AB0 SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 128 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE

More information

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0

6ES7 313-6BE01-0AB0 6ES7 313-5BE01-0AB0 4 SIMATIC S7-300 Central processing units CPU 312C to CPU 317F-2 DP CPU 317F-2 DP The failsafe CPU with a large program memory and quantity framework for demanding applications For configuration of a failsaf

More information

CPUs - CPU 315-2 PN/DP

CPUs - CPU 315-2 PN/DP Overview The CPU with a medium program memory and quantity framework High processing performance in binary and floating-point arithmetic Used as a central controller on production lines with central and

More information

SIMATIC S7-300. 5/30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module

SIMATIC S7-300. 5/30 SIPLUS digital modules 5/30 SIPLUS SM 322 digital output module. 5/31 Analog modules 5/31 SM 331 analog input module /2 Central processing units /2 Standard CPUs /2 CPU 312 /2 CPU 314 /2 CPU 31-2 DP /2 CPU 31-2 PN/DP /3 CPU 317-2 PN/DP /17 Fail-safe CPUs /17 CPU 31F-2 DP /17 CPU 31F-2 PN/DP /18 CPU 317F-2 PN/DP /30 SIPLUS

More information

http://support.automation.siemens.com/ww/view/en/4067870&td=1

http://support.automation.siemens.com/ww/view/en/4067870&td=1 6ES7316-2AG00-0AB0 SIMATIC S7-300, CPU 316 Technical / CAx data nmlkji Technical Data nmlkj CAx data As of 2010-01-24 Power supply Input voltage Rated value (DC) permissible range, lower limit (DC) permissible

More information

Data sheet SLIO CPU 015 (015-CEFPR00)

Data sheet SLIO CPU 015 (015-CEFPR00) Data sheet SLIO CPU 015 (015-CEFPR00) Technical data Order no. 015-CEFPR00 SLIO CPU 015 Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max. 512 kb)

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE T I A Training Document Page 1 of 25 Module This document has been written by Siemens AG for training

More information

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules

SIMATIC S7-300 4/2 Introduction Function modules (continued) 4/4 Central processing units 4/38 SIPLUS central processing units 4/40 Digital modules /2 Introduction /2 S7-300/S7-300F / Central processing units / CPU 312C to CPU 317F-2 DP /38 SIPLUS central processing units /38 SIPLUS CPU 312C, CPU 313C, CPU 31, CPU 315-2 DP /0 Digital modules /0 SM

More information

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module

Siemens AG 2011. 3/42 Analog modules 3/42 EM 231 3/42 EM 232 3/42 EM 235 3/47 EM 231 thermocouple module 3/49 EM 231 RTD module Siemens AG 2011 /2 Introduction /4 Central processing units /4 CPU 221 /4 CPU 222 /4 CPU 224 /4 CPU 224 XP, CPU 224 XPsi /4 CPU 226 /24 SIPLUS central processing units /24 SIPLUS CPU 221 /25 SIPLUS CPU

More information

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules

SIMATIC S7-300. 4/2 Introduction. 4/4 Central processing units. 4/34 Digital modules. 4/44 Analog modules. 4/55 F digital /analog modules /2 Introduction / Central processing units /3 Digital modules / Analog modules /55 F digital /analog modules /61 Ex input/output modules /65 Function modules /65 FM 350-1 counter module /67 FM 350-2 counter

More information

Fieldbus slave modules with I/Os, DIO

Fieldbus slave modules with I/Os, DIO 140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data Standard CPUs CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 147 x 129 mm 35 x 147 x 129 mm 70 x 147 x 129 mm Spare part availability after 10 years

More information

CP 342-5. Page 1342 Mar 2008 Siemens ITS

CP 342-5. Page 1342 Mar 2008 Siemens ITS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication

More information

Main Catalog 2012/2013 for specialists in automation and control technology

Main Catalog 2012/2013 for specialists in automation and control technology Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced

More information

The CP 342-5 provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 provides access to different communication services of the PROFIBUS bus system: SIPLUS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7

More information

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten.

PROFINET the Industrial Ethernet standard. Siemens AG 2013. Alle Rechte vorbehalten. the Industrial Ethernet standard is 100% Ethernet is Ethernet Ethernet is the established standard in the IT world for fast exchange of data (IEEE 802.3) is always full duplex simultaneous communication

More information

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.

SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved. SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,

More information

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:

The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7

More information

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup.

SIMATIC. C7-621, C7-621 AS-i Control Systems. Volume 2 Working with C7 A B C D E. Contents. User Information. Introduction. Startup. Contents User Information Introduction 1 Startup 2 SIMATIC C7-621, C7-621 AS-i Control Systems Volume 2 Working with C7 Manual Controlling Controlling with the C7 CPU 3 Addessing, Parameter Assignment,

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

S7-1500/S7-1500F Technical Data

S7-1500/S7-1500F Technical Data CPU 1511-1 PN CPU 1513-1 PN CPU 1515-2 PN Type Standard CPU Standard CPU Standard CPU Dimensions 35 x 125 x 130 mm 35 x 125 x 130 mm 70 x 147 x 129 mm Spare part availability after 10 years 10 years 10

More information

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300

SIMATIC. SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 SIMATIC SM 335 High-Speed Analog Input/Output Module for the SIMATIC S7-300 Manual Preface, Contents Characteristics and Technical Specifications of the SM 335 Connecting the Inputs and Outputs of the

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

S7-1200 and STEP 7 Basic V10.5

S7-1200 and STEP 7 Basic V10.5 S7-1200 and STEP 7 Basic V10.5 S7-200 vs. S7-1200 Expandability S7-200 S7-1200 max. 7 Modules max. 3 Modules (CM) max. 8 Modules (SM) Page 2 Advantages of S7-1200, compared to S7-200 I/O Internal periphery

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3

SIMATIC NET. S7-CPs for PROFIBUS. CP 443-5 Basic. Manual Part B3 SIMATIC NET S7-CPs for PROFIBUS Manual Part B3 CP 443-5 Basic 6GK7 443-5FX02-0XE0 Version 1 and higher (firmware version V4.0 and higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs Mode selector

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Versions. Q.station Q.station T. Q.station D. Q.station DT x x Most important features: Very high data rates up to 100 khz each channel 100 khz at 16 channels, 10 khz at 128 channels 64 Q.bloxx modules connectable Ethernet interface for configuration and data output

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL PROFINET with IO Controller CPU 315F-2 PN/DP and IO Device ET 200S T I A Training Document Page 1 of

More information

PROFINET IO Diagnostics 1

PROFINET IO Diagnostics 1 PROFINET IO is a very cost effective and reliable technology. However, extensive installations can have thousands of PROFINET IO devices operating on many networks. The reliable operation of these networks

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

SOFTLINK 300. CPU Specifications. Reference Manual

SOFTLINK 300. CPU Specifications. Reference Manual SOFTLINK 300 Reference Manual This manual is part of the documentation Package with the order number 300 314-1SL01 300 314-2DP01 300 315-2DP01 Edition 04/2011 i Preface Purpose of the manual This manual

More information

NEW. EVEN MORE data acquisition and test stand automation

NEW. EVEN MORE data acquisition and test stand automation NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05 Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE PROFINET with IO-Controller CP343-1 Advanced and IO-Device ET 200S T I A Training Document Page 1 of

More information

S7 CPs for Industrial Ethernet - SIMATIC NET. S7-300 - Industrial Ethernet S7 CPs for Industrial Ethernet - CP 343-1 Advanced.

S7 CPs for Industrial Ethernet - SIMATIC NET. S7-300 - Industrial Ethernet S7 CPs for Industrial Ethernet - CP 343-1 Advanced. S7 CPs for Industrial Ethernet - CP 343-1 Advanced SIMATIC NET S7-300 - Industrial Ethernet S7 CPs for Industrial Ethernet - CP 343-1 Advanced Manual Preface Properties and services 1 Performance data

More information

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B0875-2.1 en MP85 / MP85DP Data sheet MP85 MP85DP Special features - 100% quality control of the production process - Universal twin-channel amplifier for many of the usual market sensors - Powerful algorithms for

More information

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output NTA CPU board PROCESS INTERFACES NTA is a CPU board for STAR DualBus DCS systems. NTA provides the internal bus communication, managing all I/O boards of the STAR DualBus modular system. NTA also manages

More information

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053. PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Manual 04/2007 A5E01077385-01 Safety Guidelines

More information

Cover. SEB SIMOTION Easy Basics. Collection of standardized SIMOTION basic functions. FAQ April 2011. Service & Support. Answers for industry.

Cover. SEB SIMOTION Easy Basics. Collection of standardized SIMOTION basic functions. FAQ April 2011. Service & Support. Answers for industry. Cover SEB SIMOTION Easy Basics Collection of standardized SIMOTION basic functions FAQ April 2011 Service & Support Answers for industry. 1 Preface 1 Preface The SEB is a collection of simple, standardized

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

ABB RTU560A Series CMU & Modules

ABB RTU560A Series CMU & Modules ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power

More information

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003

C7 Control Systems PLC and Operator Panel in one device. Product Brief November 2003 C7 Control Systems PLC and Operator Panel in one device Product Brief November 2003 Overview, advantages, innovation SIMATIC C7 control systems comprising SIMATIC OP & S7-300 SIMATIC OP SIMATIC S7-300

More information

Programmable Controller G Series. New. Models

Programmable Controller G Series. New. Models Programmable Controller G Series The IMO G6 is a very compact modular programmable controller offering extremely high performance. It is ideal for all applications from process control to machine control

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion

More information

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute

More information

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138. Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver

More information

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Page 1 of 13 Table of Contents 1 OVERVIEW... 3 2 INSTALLING AND CONFIGURING THE ANYBUS -X GENERIC GATEWAY AND ETHERNET

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully

More information

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC

CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules

More information

Siemens AG 2013. 6/56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module

Siemens AG 2013. 6/56 Digital modules 6/56 SM 421 digital input module 6/59 SM 422 digital output module Siemens AG 2013 SIMATIC S7-400 /2 Introduction /4 Central processing units /4 Standard CPUs /4 CPU 412 /8 CPU 414 /13 CPU 41 /18 CPU 417 /21 SIPLUS Standard CPUs /21 SIPLUS CPU 412 /22 SIPLUS CPU 414 /23

More information

SCADAPack 530E 535E. remote Programmable Automation Controller

SCADAPack 530E 535E. remote Programmable Automation Controller SCADAPack 530E 535E remote Programmable Automation Controller 1 With the SCADAPack 500E range, Schneider Electric introduces the first ever remote Programmable Automation Controller (rpac). This data sheet

More information

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

SIMATIC. S7-300 CPU 31xT. Preface. Product Overview 1. Operator controls and indicators. Setting up an S7-300 with a Technology CPU

SIMATIC. S7-300 CPU 31xT. Preface. Product Overview 1. Operator controls and indicators. Setting up an S7-300 with a Technology CPU SIMATIC S7-300 SIMATIC S7-300 Manual Preface Product Overview 1 Operator controls and indicators 2 Setting up an S7-300 with a Technology CPU 3 Communication with S7-300 4 Memory concept 5 Cycle and response

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012

Applications & Tools. Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012 Cover Configuration of Messages and Alarms in WinCC (TIA Portal) WinCC (TIA Portal) Application description December 2012 Applications & Tools Answers for industry. Siemens Industry Online Support This

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING 1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L APPLICATION NOTE AN-357 1.0 INTRODUCTION In today's highly competitive market, high quality of service, QOS, and reliability is

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se Lecture 4 Profibus Urban Bilstrup Urban.Bilstrup@ide.hh.se Profibus Outline Introduction Profibus-DP Physical Layer Link Layer Application Layer 2 Profibus Introduction Three different versions of PROFIBUS

More information

Light scene push button 8gang comfort flush-mounted 751688xx

Light scene push button 8gang comfort flush-mounted 751688xx 751688xx Documentation Product name: Light scene push button 8gang comfort Design: flush-mounting type (Up) ETS search path: Push button / Push button general / Light scene push button 8gang comfort Functional

More information

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd Overview and Applications of PROFINET Andy Verwer Verwer Training & Consultancy Ltd What exactly is PROFINET? PROFINET is an open Industrial Ethernet standard developed by the PROFIBUS Organisation. PROFINET

More information

SIMATIC NET. S7-CPs for Industrial Ethernet. CP 343-1 Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300

SIMATIC NET. S7-CPs for Industrial Ethernet. CP 343-1 Lean. Manual Part B8. Version 1 or higher (Firmware Version V1.0) for SIMATIC S7-300 / C7-300 SIMATIC NET S7-CPs for Industrial Ethernet Manual Part B8 CP 343-1 Lean 6GK7 343-1CX00-0XE0 for SIMATIC S7-300 / C7-300 Version 1 or higher (Firmware Version V1.0) LED displays TP port: 8-pin RJ-45 jack

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

PROFINET Diagnostics Software and Tools

PROFINET Diagnostics Software and Tools PROFINET Diagnostics Software and Tools Dr. Xiu Ji Static wiring test, diagnostics Live system diagnostics Basics of PROFINET Content PROFINET Diagnostics by Dr. Xiu Ji, Page 2 What is PROFINET? PROFINET

More information

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue

More information

Measuring Temperature withthermistors a Tutorial David Potter

Measuring Temperature withthermistors a Tutorial David Potter NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in

More information

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3

1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3 Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...

More information

Automating with STEP7 in LAD and FBD

Automating with STEP7 in LAD and FBD bisk Automating with STEP7 in LAD and FBD Programmable Controllers SIMATIC S7-300/400 by Hans Berger Publicis MCD Verlag Contents Indroduction 19 1 SIMATIC S7-300/400 Programmable Controller... 20 1.1

More information

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP 1. Functions An I. S. 1 fieldstation can be equipped with a primary and a redundant central unit (), whereby each has its own independent PROFIBUS

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET

PROFINET. The leading. Industrial. Ethernet. Standard. The Benefits of PROFINET PROFINET The leading The Benefits of PROFINET Industrial Ethernet Standard Automation Structure 2 ))) Automation system Industrial Ethernet Automation Structure 3 Network standard Ethernet High transmission

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0 GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...

More information

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!

MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise! Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:

More information

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols. HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter

More information

Configuring PROFINET

Configuring PROFINET CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting

More information

Ponto Series. A new concept for automation

Ponto Series. A new concept for automation Ponto Series A new concept for automation Programmable Controller Remote I/O for Field Buses Special models of I/O modules Web connection Ponto Series Programmable Controller High connectivity CPUs Direct

More information

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications

Vision OPLC. V350-35-R34/V350-J-R34 Technical Specifications. Technical Specifications Vision OPLC V350-35-R34/V350-J-R34 Technical Specifications The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3

More information

DCM. Product Brochure. Diagnostic Communication Master

DCM. Product Brochure. Diagnostic Communication Master DCM Product Brochure Diagnostic Communication Master DCM The DCM Diagnostic Communication Master is the best solution for the control of actuators from a remote control room through a two-wire transmission-mode

More information

Bellplast S.R.L. www.caipe.com Informe del Dpto. Técnico

Bellplast S.R.L. www.caipe.com Informe del Dpto. Técnico - CPU 306 EX - CPU306EX Performance Indexes K306EX-14AT K306EX-24AR CPU Program Execution DI Points DO Points Application Memory Program Backup Memory Area 16-bit industrial Typical Bool instruction time:

More information

SIMATIC. PLC S7-300, CPU Specifications CPU 312 IFM to CPU 318-2 DP A B. Preface, Contents

SIMATIC. PLC S7-300, CPU Specifications CPU 312 IFM to CPU 318-2 DP A B. Preface, Contents Preface, Contents SIMATIC PLC S7-300, CPU Specifications CPU 312 IFM to CPU 318-2 DP Reference Manual CPUs 1 CPU 31x-2 as DP Master/DP Slave and Direct Communication 2 Cycle and Reaction times 3 CPU Function,

More information

How To Sell A Talan

How To Sell A Talan The TALAN represents state-of-the-art capability to rapidly and reliably detect and locate illicit tampering and security vulnerabilities on both digital and analog telephone systems. Marketing Characteristics

More information

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-RA22/V350-J-RA22 Technical Specifications The Unitronics V350-35-RA22/V350-J-RA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information