30 X40 2 CAR GARAGE 3 ENTRY DOOR 2 WINDOWS 2-10 X10 GARAGE DOORS SHOP SPACE 4 CONCRETE SLAB
|
|
- Erick Cannon
- 7 years ago
- Views:
Transcription
1 30 X40 2 CAR GARAGE 3 ENTRY DOOR 2 WINDOWS 2-10 X10 GARAGE DOORS SHOP SPACE 4 CONCRETE SLAB 12 WALLS 4/12 PITCH METAL ROOF METAL SIDING ELECTRICAL PLAN
2 INDEX PAGE DESCRIPTION FRONT & RIGHT ELEVATIONS BACK & LEFT ELEVATIONS FLOOR PLAN FOUNDATION PLAN SECTION A-A, H1 INSTALLATION SECTION B-B FRAME PICTORIAL, DOOR AND WINDOW SCHEDULE SPECIFICATIONS BILL OF MATERIALS TITLE PAGE 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE NTS PAGE
3 PEAK HEIGHT CEILING HEIGHT METAL ROOFING METAL FASCIA 1' RUN 12 RISE 4 VENTED SOFFIT METAL FASCIA 1 19'-1" GRADE/FLOOR METAL CORNER TRIM EACH CORNER FRONT ELEVATION VENTED RIDGE METAL SIDING METAL ROOFING PEAK HEIGHT PER CODE METAL FASCIA CEILING HEIGHT GRADE/FLOOR 1 VENTED SOFFIT 1' 19'-1" PER CODE METAL CORNER TRIM EACH CORNER FRONT AND RIGHT ELEVATIONS 463 North State, Preston, Idaho COPYRIGHT 2003 RIGHT ELEVATION METAL SIDING SCALE 1/8" = 1' PAGE 1
4 CEILING HEIGHT METAL ROOFING METAL FASCIA 1' RUN 12 RISE 4 VENTED SOFFIT METAL FASCIA 1 19'-1" GRADE/FLOOR METAL CORNER TRIM EACH CORNER BACK ELEVATION VENTED RIDGE METAL SIDING METAL ROOFING PEAK HEIGHT PER CODE METAL FASCIA CEILING HEIGHT GRADE/FLOOR 1 VENTED SOFFIT 1' 19'-1" PER CODE METAL CORNER TRIM EACH CORNER LEFT ELEVATION METAL SIDING BACK AND LEFT ELEVATIONS 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE 1/8" = 1' PAGE 2
5 40' B B 15' 1 A A 30' 9'-5" '-7" 6'-6" 11'-6" 13' 9' FLOOR PLAN 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE 1/8" = 1' PAGE 3
6 40' 2-10" 4" CONC. SLAB REINF. W/ 6X6-6/6 WELDED WIRE MESH AND REBAR PER CODE ON 4" COMPACTED GRAVEL OR SAND 30' 3'-2" 4' " 10'-3" 10'-3" -9" 3' " FOUNDATION PLAN 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE 1/8" = 1' PAGE 4
7 WP ~~ ~~ WP WP $$ $$ ELECTRICAL PLAN 463 North State, Preston, Idaho COPYRIGHT 2003 WP $ ~~ WP BREAKER BOX 110 VOLT OUTLET, SPLIT WIRED, QUADRUPLEX 110 VOLT OUTLET, WEATHER PROOF 110 VOLT OUTLET 110 VOLT OUTLET, CEILING MOUNT 110 VOLT OUTLET, CEILING DROP CORD CEILING FAN/LIGHT FLUORESCENT LIGHT PORCH LIGHT LIGHT SWITCH GARAGE DOOR OPENER SWITCH SCALE 1/8" = 1' PAGE 5
8 ENGINEERED 24" O.C. 30 PSF LIVE LOAD 15 PSF DEAD LOAD METAL ROOFING OVER 30# FELT ON 5/8" OR THICKER EXTERIOR GRADE PLYWOOD OR EQUAL INSTALLED PER MFG.'S SPECIFICATIONS SIMPSON H1 HURRICANE TIE OR EQUAL EACH TRUSS METAL DRIP EDGE METAL FASCIA OVER 2 X 8 FASCIA BOARD VENTED SOFFITS METAL SIDING OVER HOUSE WRAP ON 1/2" OR THICKER EXTERIOR GRADE PLYWOOD OR EQUAL 1/2" X 12 J-ANCHOR SPACED PER CODE DOUBLE 2 X 6 TOP PLATE 2 X 12 HEADERS 2 X 6 HEADER 2 X 6 D.F. STD & BTR. STUDS & 16" O.C. 2 X 6 HEADER 2 X 6 ROUGH SILL 2 X 6 PRESSURE TREATED OR EQUAL MUDSILL/PLATE W/ FOAM SEAL UNDERNEATH SIMPSON H1 INSTALLATION SCALE: NTS 8" 1'-6" STEEL REBAR PER CODE IN STEM WALL AND FOOTINGS 9" 4" MIN. COMPACTED GRAVEL OR SAND 4" CONC. SLAB REINFORCE W/ 6x6-6/6 WELD WIRE MESH, AND REBAR PER CODE SECTION A-A, H1 INSTALLATION 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE 1/4" = 1' PAGE 6
9 2 X 4 NAILER 2 X 8 FLY RAFTER METAL DRIP EDGE OVER METAL FASCIA OVER 2 X 8 FLY RAFTER ENGINEERED REDUCED GABLE END TRUSS 2 X 4 O.C. ENGINEERED O.C. INSTALL BLOCKING AS REQ'D PER CODE SIMPSON H1 HURRICANE TIE OR EQUAL EACH TRUSS DOUBLE 2 X 6 TOP PLATE SOFFITS METAL SIDING OVER HOUSE WRAP ON 1/2" OR THICKER EXTERIOR GRADE PLYWOOD OR EQUAL 1/2" X 12 J-ANCHOR SPACED PER CODE DOUBLE 2 X 6 TOP PLATE 2 X 6 D.F. STD & BTR. 16" O.C. 2 X 6 PRESSURE TREATED OR EQUAL MUDSILL/PLATE W/ FOAM SEAL UNDERNEATH 2 X 12 HEADERS 2 X 6 HEADER 2 X 6 CRIPPLE 2 X 6 HEADER SLAB ON STEM DOORS STEEL REBAR PER CODE 8" IN STEM WALL AND FOOTINGS 1'-6" BACK 9" 4" CONC. SLAB REINFORCE W/ 6x6-6/6 WELD WIRE MESH, AND REBAR PER CODE 4" MIN. COMPACTED GRAVEL OR SAND FRONT SECTION B-B 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE 1/4" = 1' PAGE 7
10 NOTE: FRAME PICTORIAL IS ONLY TO GIVE A GENERAL IDEA OF HOW FRAME PARTS FIT TOGETHER IT IS NOT AN ACTUAL REPRESENTATION OF THE FINISHED FRAME. USE THE DETAILED DRAWINGS FOR ACTUAL CONSTRUCTION INFORMATION. DOOR AND WINDOW SCHEDULE SYMBOL SIZE DESCRIPTION QTY 1 3' X 6'-8" 2 10' X10' 1 4' X 3' 2 5' X 3' EXTERIOR ENTRY DOOR 1 SECTIONAL GARAGE DOOR 2 WINDOW (OWNERS OPTION) WINDOW (OWNERS OPTION) 1 1 FRAME PICTORIAL, DOOR AND WINDOW SCHEDULE 463 North State, Preston, Idaho COPYRIGHT 2003 SCALE NTS PAGE 8
11 General Specifications and Notes General: 1. Construction shall meet all applicable codes and ordinances. Site Work: 1. Make sure setbacks are in compliance with those shown on plans and local building codes. 2. All stumps, roots, and organic matter shall be removed from the soil in the area of the building. 3. Lot must be graded to insure proper drainage. This must be completed prior to final inspection. 4. Soil should not be a highly expansive soil type without having a soil report preformed by a soils engineer and receiving approval from local building department to construct building on said type soil. 5. Soil bearing capacity assumed to be 1500 psi at 2 below adjacent finished grade for design. 6. Bottom of footings shall be placed 30 minimum below existing grade and tops of stems shall be 10 minimum above finished grade or per code if greater. Concrete: 1. All slabs are to be 4 concrete over 4 gravel unless otherwise noted on the plans. 2. Concrete to be ACI , Type II cement, 2500 psi at 28 days, 5 maximum slump. 3. Reinforcing to be ASTM A615-Bars with Fy=60 ksi lap 30 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 2500 psi for quality only. 5. Anchor bolts shall be A-307 embedded 7 minimum into concrete or masonry grout. Roof Framing: 1. Fascia to be 2 x8 Douglas Fir per detail sheet unless otherwise specified. 2. For soffit size see detail sheet. 3. For spans and dimensions refer to floor plans. 4. Trusses are to be an approved truss design from the truss manufacture s engineer. 5. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection unless otherwise specified. 6. Solid blocking required between joists, rafters, and trusses. Such blocking shall be 1 ½ minimum thickness and full depth of joists, rafters, or trusses. 7. Minimum header sizes shall be according detail sheet. 8. Basis of design roof live/snow load of 30 psf, and roof dead load of 15 psf. 9. Plywood roof decking to be 5/8 thick, 24/0, CDX or equal wafer unless otherwise specified. Woods: General framing: (Douglas Fir) 1. Brace all exterior walls and cross-stud partitions at each end of building and at least every 25 of length by one of the following: a. Simpson WB 126 wall bracing with 3-16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of 3/8 inch. 3. Fire stopping: a. Fireblock stud spaces over 10 in height, furred spaces, soffits, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2 nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. PAGE 9 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs. 5. Exterior wall framing to be 2 x6 studs at 16 o.c. Interior wall, framing at non-bearing walls to be 2 x4 studs at 24 o.c. and at bearing walls 2 x4 studs at 16 o.c. with double top plate unless otherwise specified. 6. Shear wall to be 1/2 CDX plywood. 7. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates. 11. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. 13. Use pressure treated lumber or redwood any place wood contacts concrete or is closer than 8 to the soil. Thermal and Moisture Protection: 1. Metal roofing over Type 30 felt over 5/8 minimum CDX plywood or equal wafer board installed per manufacturer s instructions. 2. Install caulking compound at all penetrations in building envelope, i.e., holes drilled in top plates around windows, doors, and service entrance panel. 3. Cover the building exterior walls with house wrap. 3. Wrap all framing at exterior wall penetrations with a layer of water and ice shield to prevent damage from moisture. Doors, Windows, and Glass: 1. All exterior doors to be solid core.
12 BILL OF MATERIALS ID Size Item Count Un GN1 48 high wall Foundation 8" Concrete Stem Wall 138 ft GN2 120 high wall Metal Siding 139 ft GN /16 high wall Metal Siding 79 ft FO1 8" thick Concrete Concrete cuyd FO2 2x6" treated mud sill 138 ft FO3 1/2x6" foam sill seal 138 ft FO4 foundation bolts 29 FO5 18x9"h concrete footing 5.72 cuyd FO6 no. 4 rebar (footing) 299 ft FO7 no. 4 horiz. rebar (wall) 1493 ft FO8 no. 4 vert. rebar (wall) 560 ft FO sq ft concrete slab cuyd FO sq ft steel mesh for slab 1108 sqft F1 2x6-16ft+ fir plate 424 ft F2 2x6"-115 1/2" fir stud 99 F3 2x6"-52 3/4" fir stud 2 F4 2x6-16ft+ fir stud stock 13 ft F5 2x7-16ft+ header - lumber 16 ft F6 2x6"-8 1/2" fir stud 16 F7 2x12-16ft+ header - lumber 43 ft F8 2x11-16ft+ header - lumber 11 ft F9 2x6-16ft+ fir stud stock 259 ft F10 2x6-16ft+ fir plate 236 ft S1 36" wide Metal Siding 477 ft S2 4x8x1/2 Sheet Plywood 53 S3 house wrap 1380 sqft EX1 1x7-36" door threshold 1 EX2 1x4-16ft+ ext. door casing 18 ft EX3 7 in ext. door jamb 18 ft EX4 1x4-16ft+ exterior sill 11 ft EX5 1x4-16ft+ ext. window casing 24 ft EX6 1x4-16ft+ garage door casing 63 ft EX7 7 in garage door jamb 63 ft R1 TR-1 reduced gable end roof truss 2 R2 TR-0 roof truss 14 R3 2x8"-16'+ ridge board - lumber 31 ft R4 2x8"-3 rafters - lumber 2 R5 2x8"-23' rafters - lumber 4 R6 4x2"-16'+ rafters - lumber 68 ft R7 ridge vent 32 ft R8 ridge cap 32 ft R9 Roofing Metal 1417 sqft R10 4x8' sheets roof sheathing 45 R11 2x8" gable fascia 89 ft R12 2x8" eave fascia 64 ft R13 metal drip edge 153 ft W1 48x36 window 1 W2 60x36 window 1 CONTINUED NEXT PAGE PAGE 10
13 D1 36x80x1 3/4R ext. door hinged 1 D2 120x120 garage door 2 T1 1x2-16ft+ interior casing 40 ft T2 1x2-16ft+ window apron 10 ft T3 1x2-16ft+ sill 10 ft Warning: This is a computer generated estimate of the materials needed. It is not to be construed as an accurate or complete list of materials. For a more accurate list of materials needed, you will have to calculate it by hand. PAGE 11
Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems
P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationFree 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details
Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details Brought To You By: MyShedPlans Click Here To Download 12,000 Shed Plans >> 12 x 8 Basic Shed This 8 12-ft. shed features a simple
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationSUPER SHED. Indoor shelter for your outdoor tools.
SUPER SHED Indoor shelter for your outdoor tools. Not everyone needs a garden shed. But, if you've no more space on your garage wall for that new leaf rake, if you can't find your potting trowel because
More informationPatio Covers / Carports
Patio Covers / Carports Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationNCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationCLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
More information1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.
Formulas: Formula Letters: H= Height BCY = Bank Cubic Yards L= Length CCY = Compact Cubic Yards P= Perimeter LCY = Loose Cubic Yards LF = Linear Feet or Lineal Feet BF = Board Foot or Feet SF = Square
More informationThe better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs
The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs February 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements...................................
More informationHURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationBest Barns USA Assembly Book
Best Barns USA Assembly Book Revised November 27, 2013 the Easton - R 12'x 20' Manufactured by Reynolds Building Systems, Inc. 205 Arlington Drive Greenville, PA 16125 724-646-3775 This manual is copyrighted.
More information4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
More informationPDmB, Inc. Definitions
Page 1 of 11 Definitions S Satisfactory Meets industry standards for proper material and installation NP Not Present Condition or item was not present at time of inspection NI Not Inspected Condition or
More informationCONSTRUCTION DETAILS & LOAD DESIGN CHARTS
Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description
More information1/2" CDX PLY W/ 8d @ 6"/ 6"/ 12" 2x ROOF RAFTERS @ 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)
TYPE V CONSTRUCTION IS A CLASSIFICATION OF BUILDINGS BY CONSTRUCTION MATERIALS AND METHODS. IT IS THE LEAST RESTRICTIVE PERMITTED BY THE UNIFORM BUILDING CODE AND INCLUDES LIGHT, WOOD-FRAME CONSTRUCTION.
More informationTYPICAL PATIO COVERS 111
City of Laguna Niguel Building Division 30111 Crown Valley Pkwy Laguna Niguel, CA 92677 (949) 362-4360 FAX 362-4369 www.cityoflagunaniguel.org TYPICAL PATIO COVERS 111 PLEASE NOTE: This information Bulletin
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More informationPole Building Estimate Number: 4992 12/2/2010 NORTH SIDE-EAVE SIDE 2 ELEVATION
NORTH SIDE-EAVE SIDE 2 ELEVATION SOUTH SIDE-EAVE SIDE 1 ELEVATION WEST SIDE-GABLE SIDE 2 ELEVATION EAST SIDE-GABLE SIDE 1 ELEVATION Wheeling Centurydrain Steel Roofing Metal Drip Edge Facia Board Facia
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationCITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST
CITY OF BERKELEY DETAILED CHECKLIST This checklist will assist you in preparing plans for submittal with a building permit application. Alterations, additions and remodeling projects may not require all
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationBUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
More information8/18/14. Introduction to. Framing. Terminology and Concepts
8/18/14 Introduction to Framing Terminology and Concepts Terminology: Framing Level Two points on exactly the same horizontal plane. Square Intersecting lines or faces that form an exact 90 angle. Plumb
More informationResidential Building Inspection Policies
CONCRETE 1. A footing inspection has been called in, but a monolithic slab shows on the plans. Cancel the footing and create a slab inspection, as long as there is a Passed Plumbing Rough (05). 2. A stemwall
More informationWhitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationRESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS
RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS Johnson County Building Officials Association January 2008 Residential Foundation Guideline Foundation designs for one-and two-family dwellings may use
More informationSection A Roof Truss
Section A Roof Truss Truss Types Wisconsin Truss, Inc. can build a variety of truss types, pictured below are some common examples. Common Bobtail Scissor Mono Studio Dual Slope Cathedral Tray Vault Parallel
More informationUncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationPre-Drywall Inspection Report
SM MEDALLION INSPECTIONS helping people make informed decisions Pre-Drywall Inspection Report 5657 Garden Valley Place Milton, Georgia 30024 Prepared for Betsy and Paul Dougherty January12, 2015 Medallion
More informationLeaky Homes Financial Assistance Package (FAP) Repair plan example
LEAKY HOMES FINANCIAL ASSISTANCE PACKAGE FACT SHEET Repair Plan Example - June 2014 Page 1 Leaky Homes Financial Assistance Package (FAP) Repair plan example Introduction This repair plan example is intended
More informationREQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION
RESIDENTIAL: REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION 2 COMPLETE SETS OF PRINTS WITH ENGINEERS STAMP ON FOUNDATION PLAN INCLUDING ELECTRICAL, PLUMBING, ETC. SITE PLAN SHOWING HOUSE LOCATION
More informationNRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
More informationGeorgia Association of Home Inspectors
Georgia Association of Home Inspectors Standards of Practice for Framing Inspections OVERVIEW The purpose of the GAHI (Georgia Association of Home Inspectors) Standards of Practice for Framing Inspections
More informationThe better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationBuilding Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationNAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05)
NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES Public Works/Planning & Zoning Building & Safety AMENDED (05-02-05) NAVAJO COUNTY GOVERNMENTAL COMPLEX P.O. BOX 668 HOLBROOK, ARIZONA
More informationChapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.
Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION
More informationHow to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
More informationAttached/Detached Patio Cover/Carport
CITY OF MANTECA COMMUNITY DEVELOPMENT DEPARTMENT 1001 West Center Street Manteca, CA 95337 FAX (209) 923-8955 Building Safety Division (209) 456-8550 Community Development/Planning Division (209) 456-8500
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationSECTION 3 ONM & J STRUCTURAL ANALYSIS
Historic Boynton Beach High School Existing Building Assessment City of Boynton Beach February 10, 2011 SECTION 3 ONM & J STRUCTURAL ANALYSIS STRUCTURAL ENGINEERS SPECIAL INSPECTORS STRUCTURAL CONDITION
More informationHomeSpec REPORT SUMMARY
HomeSpec 04/25/2007 Ms. Rachel Trujeque Re: 13038 West Plum Road Lot #1225 - Peoria, AZ. 85383 - Pre Drywall Inspection Dear Ms. Trujeque, At your request, a visual pre drywall inspection of the above
More informationMUNICODE SERVICES LTD.
The Preserved Wood Foundation Guide MUNICODE SERVICES LTD. Prepared by MuniCode Services Ltd. Outline and Restrictions of this Guide The following information required for the construction of Preserved
More informationExcerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationHow To Repair A Boat Landing Deck With A Boat Bed
RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing
More informationA0 SHEET 1 OF 5 400 LOCUST STREET FRANKFORT, KANSAS 66427 FRANKFORT, KANSAS 66427 ROOF REPAIR OF THE 400 LOCUST STREET
POYNTZ AVENUE, STE 9 MANHATTAN, KS 0..0..9 FAX WEST th STREET JUNCTION CITY, KS.... FAX 0, Bruce McMillan AIA, Architects, P.A. HERITAGE TRUST FUND GRANT PROJECT NO. 0-0 ROOF REPAIR OF THE 00 LOCUST STREET
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationDEFAULT HEAT LOSS COEFFICIENTS
DEFAULT HEAT LOSS COEFFICIENTS SECTION A101 GENERAL REQUIREMENTS A101.1 Scope. The following defaults shall apply to Chapter 4 of both the (RE) and (CE) sections of the IECC. This chapter includes tables
More informationCITY OF SELMA, TEXAS Inspection Checklist: Commercial
Rev Y71004 The Permits and Inspections Department welcomes you to the City of Selma. The following information is provided to you as guidance through the inspection process. The City of Selma provides
More informationProtecting Your Home From Hurricane Wind Damage
T H E W I N D Protecting Your Home From Hurricane Wind Damage During a hurricane, homes may be damaged or destroyed by high winds and high waves. Debris can break windows and doors, allowing high winds
More informationCOMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS
COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS Permit applicants shall submit three (3) COMPLETE SETS of plans and specifications with each application for a permit. Plans and specifications
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationFormwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
More informationCALIFORNIA BUILDING CODE
CALIFORNIA BUILDING CODE NONSTRUCTURAL DESIGN REQUIREMENTS This section contains portions of the California Building Code which relate to basic minimum nonstructural design requirements for a residence.
More informationResidential Foundations and Basements
Residential Foundations and Basements Disclaimer All of the following information is based on the 2006 International Residential Code with Kentucky Amendments. As some information is paraphrased, article
More informationProtecting Your Home from Wind Damage
Protecting Your Home from Wind Damage During severe thunderstorms or hurricanes, homes may be damaged or destroyed by high winds. Debris flying through the air can break windows and doors, allowing high
More informationEngineered Wood Foundations
Engineered Wood Foundations Emeraldfoundations.com 1 EWF Planning and Installation manual This manual will serve as a guide to planning and installing an Emerald Foundation system. This system is comprised
More information2014 FLORIDA BUILDING CODE
MINIMUM REQUIREMENTS FOR NEW 1 & 2 FAMILY RESIDENTIAL STRUCTURES (ALL PLANS MUST BE 22 X 36 ) WIND BORNE DEBRIS AREA Is the proposed structure located in the wind borne debris area? If yes, one of the
More informationVA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
More informationPROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY
PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY GENERAL SPECIFICATIONS These specifications are intended to cover the construction of the
More informationINFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 June 26, 1998 (Revised June 4, 2014) City Planning & Development - Development Services City of Kansas
More informationLAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
More informationLINE OF EXISTING ADJACENT STRUCTURE 6" MIN. PROTECTION COURSE (NOT REQUIRED WHERE THERE IS NO ADJACENT BLDG. MOISTURE RESISTIVE MEMBRANE AT EXIST. AND NEW BLDG. AS OCCURS WATER STOP SLAB-ON-GRADE TERMINATION
More informationDevelopment Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings
Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings H:/forms/handouts/bldg071.docx Shed and Garage Construction
More informationRESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
More informationROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof
ROOF CONSTRUCTION The overall appearance of a building is greatly affected by the roof lines and the roofing materials. The designer has many standard designs to choose from and should be able to find
More informationVer. 2. Guide to. Inspecting Residential Brick Veneer
Ver. 2 Guide to Inspecting Residential Brick Veneer 1. A guide created by industry professionals. The knowledgeable staff at MASONPRO together with technical support from the Masonry Institute of Michigan
More informationBasic Requirements for Residential Plan Review _
Basic Requirements for Residential Plan Review _ Below you will find the basic requirements for your plan submittal. General: Drawn to scale Plan Size minimum: 9 x 12 Designer, Engineer, or Architect name,
More informationThe purpose of this document is to provide standards for persons requesting or subject to County building inspections.
STANDARD OPERATING PROCEDURE BUILDING & SITE DEVELOPMENT Number: 310.1 Approval: Yves Khawam Effective Date: December 27, 2006 Subject: Requirements for County building inspections Page 1 of 7 1.0 PURPOSE:
More informationThe minimum reinforcement for the stem wall is the placement of:
PolySteel creates an ideal insulated stem wall for concrete slabs that can make this part of your project easier and faster, in addition to making your finished project more energy-efficient. Figures 3.20
More informationCity of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures
City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures SECTION 7201 - PURPOSE The purpose of this appendix chapter is to establish minimum prescriptive standards
More informationPost and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
More informationFooting and Temporary Power Inspection
Footing and Temporary Power Inspection Address: Date: Permit #: Inspector: # General Code Sec. OK C* Number, Location and Remarks 1 Permit posted on site Local 2 Port-o-let Local 3 Setbacks - front, sides,
More informationINFORMATION BULLETIN NO.
Requirements for Plans Review Submittal, One- and Two-Family Dwellings INFORMATION BULLETIN NO. 100 (June 26, 1998, Revised March 26, 2009) City Planning & Development - Development Services City of Kansas
More informationChapter 3 FOUNDATIONS AND FOUNDATION WALLS
Chapter 3 FOUNDATIONS AND FOUNDATION WALLS This chapter discusses foundations and foundation walls constructed using the two most common foundation materials concrete and masonry. Although the IRC permits
More informationPANEL CONCEPTS LLLP.
The Small Cottage Company DO-IT-YOURSELF CABINS & COTTAGES PANEL CONCEPTS INC. PANEL CONCEPTS LLLP. 2826 Gold 331 Creek N. M-33, Road Mio, Gold Michigan Creek, Montana 4864759733 (989) 826-6511 (406) 288-8585
More informationGeneral Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout
General Approach Sketch general structural layout Determine roof loading Determine required lumber dimensions Transfer load down the structure Structure Components Plants Structure Components Top Side
More informationScrew Patterns Roof & Walls 403-279-2766 TR-36 MD-36 TSM-32. PBR-Panel
Screw Patterns Roof & Walls Overlap Underlap ¾ 9 TR-36 36 5/8 6 MD-36 36 ½ 8 TSM-32 32 1¼ 12 PBR-Panel 36 Bottom Edge Screw Pattern apply to every profile except for MD36 (1 screw beside every rib) High
More informationTABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
More informationBuilding Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
More informationSample Drawing Package for One and Two Family Dwelling Applications
Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More information