Most Common Errors in Seismic Design under ASCE 7-10 and IBC 2012
|
|
- Stephanie Nichols
- 7 years ago
- Views:
Transcription
1 Most Common Errors in Seismic Design under ASCE 7-10 and IBC 2012 Robert B. Paullus, Jr., P.E., S.E. Paullus Structural Consultants
2 Acknowledgements Based Heavily on: The Most Common Errors in Seismic Design'And How to Properly Avoid Them NCSEA 2014 Annual Conference Proceedings By Thomas F. Heausler, PE, SE Structural Engineer Kansas City, MO 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 2
3 Preface Listing of common errors was developed by Tom Heausler and Bob Paullus during review of other engineers work Based On Experience Should not be misconstrued as a consensus document of the ASCE 7 Seismic Subcommittee May be used as a checklist for Design or Review 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 3
4 Standards Covered ASCE 7-10 IBC 2012 AISC ASIC ACI (including Chapter 21 and Appendix D) Other Standards 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 4
5 Favorite Top Ten Errors No. 10: Neglecting Additional Requirements for Chords, Collectors, & Diaphragms No. 9: Improper Distribution Base Shear over Height No. 8: Failure to multiply E by 0.7 for ASD design No. 7: Neglect of combining orthogonal Effects No. 6: R-Value - Improper Seismic System 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 5
6 Favorite Top Ten Errors No. 5: Modal Response Spectrum Analysis will Capture All Irregularities and be Conservative No. 4: Neglecting Vertical Seismic Load Effect - E v Particularly Critical on Cantilevered Elements No. 3: No or Inadequate Redundancy in System No. 2: No Continuous Load Path No. 1: I Didn t know Y all Had Earthquakes Around Here! 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 6
7 Seismic Design Category (SDC) A ASCE 7-10 Section Mapped Acceleration Parameters ASCE 7-10 Section SEISMIC DESIGN CATEGORY ASCE 7-10 Section DESIGN REQUIREMENTS FOR SEISMIC DESIGN CATEGORY A Send to Section 1.4 -General Structural Integrity Freeboard Requirements for RC IV Tanks: Section OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 7
8 Seismic Design Category (SDC) A ASCE 7-10 Section 1.4 -General Structural Integrity Should Not Use Any Of The Provisions Of Chapter 12 Instead, Use The General Structural Integrity Provisions Of Section 1.4 General Structural Integrity Provisions Have Some Loads Which May Often Be Erroneously Unaccounted For: The forces required include 1% dead load, 5% of dead plus live load for beam connections, and 20% of wall weight for wall connections Non-Structural Components in Seismic Design Category A are exempt from Seismic Design requirements, as stated in Section OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 8
9 Importance Factor ASCE 7-10 Section ,Table 1.5-2, Table IBC 2012 Table Importance Factor Is Based Upon Risk Category And The Associated Life Safety, Hazard And Essential Nature Of The Structure 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 9
10 Importance Factor Check both ASCE 7 and IBC Tables A typical building can sometimes evolve into an I e equal to 1.25 or 1.5 when occupancy or use expands. Examples: even relatively small churches (occupancy greater than 300) a building where hazardous materials are stored For Building Design I e = 1.0, 1.25, OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 10
11 Importance Factor Non-Structural Components I p = 1.0, or 1.5 only ASCE 7-10 Section I p may not equal I e, and in some instances I p may be less than I e OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 11
12 Continuous Load Path ASCE 7-10 Section Very Specific Provisions for Many Elements Collectors Connections Diaphragms Walls Others 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 12
13 Continuous Load Path ASCE 7-10 Section In Addition To The Specifics, The Engineer Is Required To Provide A Continuous Load Path For All Inertial Forces From Their Origin To The Foundation Such Load Path Shall Conform To The Relative Stiffness And Strength Of The Elements Which Exist In The Structure Deformational Compatibility 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 13
14 Response Modification Factor: R ASCE 7-10 Table and , 2 The Response Modification Coefficient, R, Is Part Of A Concept Where An Elastic Design May Be Performed But With Due Consideration Of The Overstrength And Ductility Inherent In The Lateral Force Resisting System OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 14
15 Response Modification Factor: R To Assure Reliability In The Overstrength And Ductility, Many Requirements Are Triggered With Each R Factor R Tables List The Detailing Requirements Triggered The Strings Attached To AISC R>3 Structures And ACI Chapter 21 Structures Can Be Extremely Significant 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 15
16 Overstrength Factor: Ω 0 ASCE 7-10 Table Also in ASCE 7-10 Tables , and When Diaphragms Are Flexible Allowed To Reduce Ω 0 Factor By 0.5 This Provision Is Listed In Small Print As Footnote g And Is Often Overlooked 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 16
17 Modal Response Spectrum Analysis Triggers ASCE 7-10 Section 12.3 Table Horizontal Irregularities Table Vertical Irregularities Tables Describe Various Irregularities and Trigger Specific Provisions One Such Provision Is Elimination Of The Option Of The Equivalent Lateral Force Procedure ASCE 7-10 Section 12.8 and the Need To Perform a Modal Dynamic Response Spectrum Analysis 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 17
18 Modal Response Spectrum Analysis Triggers ASCE 7-10 Section 12.3 Table and Table Tables Require Close Review To Interpret The Triggers. The ASCE Design Guide Seismic Loads: Guide To The Seismic Provisions Of ASCE 7-10 By Finley Charney Has A Listing Of The Triggers In A More User Friendly Format 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 18
19 Overstrength Factor, Ω 0,Triggers ASCE 7-10 Section Load Combinations with Ω 0 ASCE 7-10 Section Cantilever Columns ASCE 7-10 Section Collectors Light Frame, Wood Excepted ASCE 7-10 Section Columns, Beams Supporting Discontinuous Walls ASCE 7-10 Section Pile Anchorage AISC where R>3 ACI Chapter 21, Appendix D, etc OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 19
20 Overstrength Factor, Ω 0,Triggers Ω 0 Is An Amplification To The Forces In Certain Elements In The Seismic Load Path Required To Prevent A Weak Link Form Occurring Prior To The Full Energy Dissipation And Ductility Potential Of The Primary Feature Of The Lateral System 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 20
21 Overstrength Factor, Ω 0,Triggers Ω 0 Is An Amplification To The Forces For Example: In a steel braced frame system, in order for the diagonal brace to yield and dissipate energy in a controlled and reliable manner, all other portions of the load path (E.G. Connections, bolts, welds, gusset plates, anchor bolts, columns and collectors) need to be stronger than the maximum anticipated strength, or force, in the brace. Therefore, omega zero amplification and load combinations are specifically triggered in the sections mentioned above and in material standards such as AISC and ACI OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 21
22 Redundancy Rho (ρ) Rho Is A Factor That Penalizes Structures That Do Not Have Redundancy ASCE 7-10 Section Rho = 1.0 or 1.3 Rho = 1.0 for: SDC B, C, for Drift Calculations, F p (Non-structural Components) Forces, Collectors, Ω 0 Load Combinations, and Diaphragms 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 22
23 Vertical Seismic Load Effect - E v ASCE 7-10 Section Requires That A Vertical Load Effect Equal To 0.2 S DS Be Applied To Dead Load It Is Applied As A Dead Load Factor Adjustment And May Act Downward Or Upward It Is At Strength Design Level So It May Be Multiplied By 0.7 For Allowable Stress Design (ASD). No I e, I p, or Rho Is Applied To E v 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 23
24 Load Combinations and Allowable Stress Design 0.7 E For Allowable Stress Design (ASD) Load Combinations ASCE 7-10 Section Section shall be used in lieu of Sections and Earthquake Forces Are At Strength Level So For The ASD Combinations, Use 0.7 E (For LRFD Use 1.0 E) The 0.7 E Applies To F p (Non-structural Component Forces) Also 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 24
25 Orthogonal Effects Earthquake Forces Shall Be Calculated For Each Of The Two Primary Orthogonal Directions To Consider The Effects Of Earthquake Forces At Some Angle Other Than Those Two Directions, Orthogonal Effects Must Be Considered 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 25
26 Orthogonal Effects ASCE 7-10 Section 12.5 Requires That Irregular Buildings In SDC C, And Corner Columns In SDC D,E,F Be Considered With 100% Of Forces In One Directions And 30% In Other It Should Be Noted That IEEE 693 (Electrical Equipment) Applies Orthogonal Effects To All Conditions, Including Corner Anchor Bolts 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 26
27 Effective Seismic Weight ASCE 7-10 Section defines the Effective Seismic Weight, W. Except as mentioned below, live load is not included in the inertial force, however the seismic force is later combined with dead and live loads in the load combinations ASCE 7-10 Section stipulates that W shall include the following masses: 25% of Storage live load, Partitions 10 psf 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 27
28 Effective Seismic Weight ASCE 7-10 Section Industrial Operating Weight (and unbalanced conditions), 20% of snow > 30psf, and Roof Gardens OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 28
29 Period T ASCE 7-10 Section has complex methods and limits on calculating the Period T. It Is Acceptable To Use T = Ta, For Simplicity Approximate Formulas Shall Not Be Used For Non-building (Industrial) Structures, ASCE 7-10 Section OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 29
30 Distribute Base Shear over Height ASCE 7-10 Section Once The Base Shear, V, Is Calculated, It Must Be Distributed Over The Height Of The Structure For A One Story Building All Of The Base Shear Would Be Applied At The Roof For Multi-story Structures: The Base Shear Must Be Proportioned To Each Floor, Not Only In Proportion To Each Floors Mass, But Also In Proportion To The Distance Of` The Floor From The Base. A Triangular Distribution Of Force Results For Regular Multi-story Buildings OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 30
31 Distribute Base Shear over Height ASCE 7-10 Section Once The Base Shear, V, Is Calculated, It Must Be Distributed Over The Height Of The Structure For Distributed Mass Structures Like Stacks And CMU Fences, The Centroid Of The Load Should Be Applied At 2/3 Of The Height Above The Base, Not 1/2 Height Or Center Of Gravity 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 31
32 Distribute Base Shear Over Height Formula ASCE 7-10 Section (Eq ) F x = C vx V C vx = w x h xk /Sum w i *h ik Spreadsheets are often used to calculate the forces at each floor level A common mistake is to have errors within the spreadsheet logic and/or calculate C vx and then multiply it by W (total Weight) or w x weight at each floor. C vx should be multiplied by the Base Shear V, and the sum of all the F x should equal 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 32
33 Modal Response Spectrum Analysis ASCE 7-10 Section 12.9 The purpose of a Modal Response Spectrum Analysis is NOT to refine the magnitude of the Base Shear Purpose IS to more accurately perform the following: Distributes Base Shear Over Height Horizontal Torsional Effects Higher Mode Effects 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 33
34 Modal Analysis ASCE 7-10 Section Scaling Of The Results Of Modal Response Spectrum Analysis Is Required And Allowed. Especially For Buildings, The Results Of The Response Spectrum Should Be Very Similar To The Base Shear When Scaling Results, One Should Verify That R, I, g (Gravity Conversion For Mass) Factors Are Included 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 34
35 Modal Analysis ASCE 7-10 Section : Results must be scaled to within 85% of V calculated by ELF Method It is often wise to check your software results with a small regular structural model where results are predictable with hand calculations Confidence is gained to use the software on a large complex structural models OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 35
36 Accidental Torsion ASCE 7-10 Section Accidental Torsion Must Be Applied In Addition To Inherent Torsion Required This Is To Prevent Weak Torsional Resisting Arrangements As Well As Account For Unexpected Distribution Of Live Load And Unexpected Stiffness Of Structural And Non-structural Elements Provision Applies To Non-building Structures As Well As Buildings 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 36
37 Accidental Torsion ASCE 7-10 Section For Torsionally Irregular Buildings, Amplification Of The Accidental Torsion May Be Required ASCE 7-10 Section See Figure Torsional Amplification Factor, A x Very Small Drifts Should Not Trigger a Torsional Irregularity 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 37
38 Accidental Torsion ASCE 7-10 Section ASCE 7-10 Section When Checking for Type 1a or 1b Torsional Irregularity Use Table to Determine a The Following Recommendation Is Not Currently in ASCE 7 Recommendation From Presenter, Only IFThe Story Drifts At All Locations On A Level Are Less Than 0.15 a to 0.20 a, Do Not Consider A Torsional Irregularity 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 38
39 Accidental Torsion Example: Torsion w/ Very Small Drift Assume Story Height = 10 ft. (120 inches) Assume a =0.007h sx (Worst Case In Table ) 0.2*0.007(120 ) = (120 ) = If the Maximum Story Drift (δ x max )at Any Point On The Story Being Considered Is Less Than : There Really Isn t A Torsional Irregularity Issue Certain West Coast Building Officials May Argue This Point, Since It Is Not In ASCE 7 Don t Waste Time With Values to Small to Be Significant Remember, δ= C d *(Calculated Story Drift from Point Considered) I e (δ x = C d δ ex / I e ) 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 39
40 Drift Check ASCE 7-10 Section Section Drift Determination ASCE 7-10 Table Allowable Drift Limits Results from the elastic analysis must be amplified by C d to render actual expected deflections. C d is a very large value, typically a factor of about 3 to OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 40
41 Drift Check ASCE 7-10 Table Allowable Drift Limits The drift is then divided by I e, because the allowable drifts are organized into a table which considers Risk Category Be careful when using Allowable Stress Design load combinations DO NOT apply the 0.7E to drift calculations 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 41
42 Diaphragm Forces ASCE 7-10 Section Forces At Lower Floor Diaphragms May Be Higher Than Those Used For The Lateral Force Resisting System Due to Diaphragms Transferring Loads from One Vertical Lateral Resisting to Another May Also Be Due to Localized Diaphragm Discontinuities, Such As Holes in Floors 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 42
43 Diaphragm Forces ASCE 7-10 Section (Eq ) F x =C vx V This Is Due To Higher Mode Effects (I.E. Modes Higher Than The First Mode) Where The Lower Floors May Be Accelerating Higher Than Calculated In (Eq ) The Diaphragm Force Equation ASCE 7-10 Section (Eq ) Is Similar To (Eq ), However F px Minimums Of (Eq ) Often Govern For The Lower Floors 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 43
44 F p Non-structural Components Chapter 13 ASCE 7-10 (Eq ) Non-structural components may also experience higher local accelerations due to higher mode effects as well as amplification of the force within the nonstructural element itself Industrial structures often feature very large F p forces 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 44
45 F p Non-structural Components Chapter 13 ASCE 7-10 (Eq ) It Is Unlikely That The F p Forces On Two Different Floors Would Occur At The Same Point In Time One Method Of Accounting For The F p Forces In A Computer Model Is To Run Two Conditions 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 45
46 F p Non-structural Components Chapter 13 To Run Two Conditions: Run V Load Combinations With The Weight Of The Equipment Included In The Seismic Weight Of The Floor And Base Shear Distributed Over The Height Per (Eq ) Run F p On Piece Of Equipment Only To Verify An Adequate Load Path To The Vertical System And/Or Foundation 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 46
47 F p Non-structural Components Chapter 13 ASCE 7-10 Section Non-Building Structures Supported By Other Structures When the Weight of the Supported Non- Building Structure is Less than 25% of the Total Structure Mass Use Chapter 13 When Non-structural Components Get Very Large, I.E. 25% or More Of Total Structure Mass Use Section OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 47
48 Large F p Non-structural Components Chapter 15 When Non-structural Components Exceed 25% Of Total Structure Mass For These Heavy Components, A Computer Model Capturing The Stiffness And Design Coefficients Of Both The Component And The Primary Structure Must Be Considered Together Must Apply E v To F p Combinations Rho (Redundancy) = 1.0 Ω 0 Does Not Apply To F p Load Combinations Except, Ω 0 Does Apply In ACI Appendix D Calculations 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 48
49 Wall Design Wall Panels Made Of Concrete And Concrete Masonry, CMU Have Performed Poorly In Past Earthquakes ASCE 7-10 Section Wall Panels ASCE 7-10 Section Wall Connections Should Be Implemented, As Well As ACI Appendix D For Anchorage 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 49
50 Foundation Ties ACI Chapter 21: To Assure That The Foundation System Acts As An Integral Unit Prevents One Column Or Wall From Moving Appreciably with Respect to Another Applies To Pile Caps In SDC C, As Well As D,E,F, and Spread Footings for SDC E and F Can Possibly Be Integral With Slab For Lightly Load Buildings (Engineered Metal Buildings) 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 50
51 Reduction of Foundation Overturning ASCE 7-10 Section Allows for a reduction of the bearing pressures at the Soil-Foundation Interface Forces may be reduced by 25% in recognition that the first mode triangular force distribution will likely not occur without higher mode effects occurring and negating the direction of the first mode Results in reduced overall overturning moments 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 51
52 Errata ASCE 7 Website and IBC 2012 Website (ICC) have the latest errata. Significant Entries Due To Typographical Or Unintended Consequences Of Changes Are Corrected In The Errata 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 52
53 IBC 2012 Overrides IBC 2012 Section 1613 IBC 2012 Section Amendments to ASCE 7-10 IBC 2012 Materials -Chapters 18 through 23 contain amendments to the ASCE 7-10 document 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 53
54 IBC 2012 Overrides ASCE 7 is on a six year update cycle and IBC is on a three year Also technical changes to IBC often have to be approved well before the issue date Inevitably, Coordination Between The Two Suffers Material Standards Issues Must Be Coordinated, Often Through Errata, Supplements Or IBC Published Amendments. It Is Essential To Periodically Check For These Changes See Standards Such As: AISC, ACI, AISI, AWC, Etc OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 54
55 ASCE 7-10 THIRD PRINTING It Is Recommended That The User Make Use Of The ASCE 7 Expanded Seismic Commentary 135 Pages Of Valuable Background Information Incorporated In The Third Printing Of ASCE 7 Only 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 55
56 ASCE 7-10 THIRD PRINTING For Those That Own A First And Second Printing, You May Download A (_.pdf) File Of The Commentary For Free From The ASCE Website This Commentary Was Developed By The NEHRP/BSSC Provisions Update Committee and Describes The Reasons For The Individual Provisions Of The ASCE 7 Standard 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 56
57 References ASCE 7-10, Minimum Design Loads for Buildings and Other Structures, Third Printing, American Society of Civil Engineers, Reston, VA IBC 2012, International Building Code 2012, International Code Council, Country Club Hills, IL 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 57
58 References ACI , American Concrete Association, Farmington Hills, MI ASCE Charney Ph.D., P.E., Finley A.: Seismic Loads: Guide to the Seismic Provisions of ASCE 7-10, American Society of Civil Engineers, Reston, VA 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 58
59 Questions? 2015 OSEA Spring Conference ASCE 7-10 Seismic - Common Errors 59
TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION
TECHNICAL NOTE On Cold-Formed Steel Construction 1201 15th Street, NW, Suite 320 W ashington, DC 20005 (202) 785-2022 $5.00 Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006
More informationCH. 2 LOADS ON BUILDINGS
CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends
More informationNovember 20, 2013. Heather Sustersic had132@psu.edu. Dear Professor Sustersic,
November 20, 2013 Heather Sustersic had132@psu.edu Dear Professor Sustersic, The following technical report was written to fulfill the requirements specified in the Structural Technical Report 4 assignment
More informationCover. When to Specify Intermediate Precast Concrete Shear Walls. 10.10 Rev 4. White Paper WP004
Cover Introduction In regard to precast concrete systems, the addition of two new categories of Seismic Force Resisting Systems (SFRS) in IBC 2006 has created some confusion about whether to specify intermediate
More informationSEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:
SEISMIC DESIGN Various building codes consider the following categories for the analysis and design for earthquake loading: 1. Seismic Performance Category (SPC), varies from A to E, depending on how the
More informationUntopped Precast Concrete Diaphragms in High-Seismic Applications. Ned M. Cleland, Ph.D., P.E. President Blue Ridge Design, Inc. Winchester, Virginia
Untopped Precast Concrete Diaphragms in High-Seismic Applications Ned M. Cleland, Ph.D., P.E. President Blue Ridge Design, Inc. Winchester, Virginia S. K. Ghosh, Ph.D. President S. K. Ghosh Associates,
More informationChapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the
More informationFOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
More informationPrepared For San Francisco Community College District 33 Gough Street San Francisco, California 94103. Prepared By
Project Structural Conditions Survey and Seismic Vulnerability Assessment For SFCC Civic Center Campus 750 Eddy Street San Francisco, California 94109 Prepared For San Francisco Community College District
More informationNational Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination
Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)
More informationComparison of the Structural Provisions in the International Existing Building Code 2012 versus the Rhode Island State Rehabilitation Code
August 3, 2012 Existing Building Code 2012 versus the Rhode Island State By: Structural Engineers Association of Rhode Island, Building Code Committee Introduction At the request of the Building Code Standards
More informationDesign for Nonstructural Components
14 Design for Nonstructural Components Robert Bachman, S.E., John Gillengerten, S.E. and Susan Dowty, S.E. Contents 14.1 DEVELOPMENT AND BACKGROUND OF THE REQUIREMENTS FOR NONSTRUCTURAL COMPONENTS... 3
More information4B-2. 2. The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.
Shear Walls Buildings that use shear walls as the lateral force-resisting system can be designed to provide a safe, serviceable, and economical solution for wind and earthquake resistance. Shear walls
More informationSPECIFICATIONS, LOADS, AND METHODS OF DESIGN
CHAPTER Structural Steel Design LRFD Method Third Edition SPECIFICATIONS, LOADS, AND METHODS OF DESIGN A. J. Clark School of Engineering Department of Civil and Environmental Engineering Part II Structural
More informationSpecification for Structures to be Built in Disaster Areas
Ministry of Public Works and Settlement Government of Republic of Turkey Specification for Structures to be Built in Disaster Areas PART III - EARTHQUAKE DISASTER PREVENTION (Chapter 5 through Chapter
More informationThe ASCE 7 standard Minimum Design Loads for
Significant changes from ASCE 7-05 to ASCE 7-10, part 1: Seismic design provisions S. K. Ghosh This paper presents the major changes that have taken place in the seismic design provisions from ASCE (American
More informationOverhang Bracket Loading. Deck Issues: Design Perspective
Deck Issues: Design Perspective Overhang Bracket Loading Deck overhangs and screed rails are generally supported on cantilever brackets during the deck pour These brackets produce an overturning couple
More informationSteel joists and joist girders are
THE STEEL CONFERENCE Hints on Using Joists Efficiently By Tim Holtermann, S.E., P.E.; Drew Potts, P.E.; Bob Sellers, P.E.; and Walt Worthley, P.E. Proper coordination between structural engineers and joist
More informationExpected Performance Rating System
Expected Performance Rating System In researching seismic rating systems to determine how to best classify the facilities within the Portland Public School system, we searched out what was used by other
More information[TECHNICAL REPORT I:]
[Helios Plaza] Houston, Texas Structural Option Adviser: Dr. Linda Hanagan [TECHNICAL REPORT I:] Structural Concepts & Existing Conditions Table of Contents Executive Summary... 2 Introduction... 3 Structural
More informationWisconsin Building Products Evaluation
Safety & Buildings Division 201 West Washington Avenue P.O. Box 2658 Madison, WI 53701-2658 Evaluation # 200813-O Wisconsin Building Products Evaluation Material Best Management Standards for Foundation
More informationChapter 3 - Structural Design
Chapter 3 - Structural Design 3.0 General 3.0.1 Design Overview Greenhouse buildings are a complete structure including the structural support and enclosure elements. The primary structural system includes:
More informationSLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:
Reading Assignment SLAB DESIGN Chapter 9 of Text and, Chapter 13 of ACI318-02 Introduction ACI318 Code provides two design procedures for slab systems: 13.6.1 Direct Design Method (DDM) For slab systems
More informationStructural Failures Cost Lives and Time
Structural Failures Cost Lives and Time Recent failures of storage bins, silos and other structures highlight the need to increase awareness of hazards associated with these structures. Since 2010, one
More informationWhat is Seismic Retrofitting?
What is Seismic Retrofitting? SEISMIC RETROFITTING A Seismic Retrofit provides existing structures with more resistance to seismic activity due to earthquakes. In buildings, this process typically includes
More informationReinforced Concrete Design
FALL 2013 C C Reinforced Concrete Design CIVL 4135 ii 1 Chapter 1. Introduction 1.1. Reading Assignment Chapter 1 Sections 1.1 through 1.8 of text. 1.2. Introduction In the design and analysis of reinforced
More informationLoads and Load Combinations for NBCC. Outline
Loads and Load Combinations for NBCC Prepared by Dr Michael Bartlett, P.Eng University of Western Ontario Presented with minor modifications by Dr Robert Sexsmith, P.Eng. University of British Columbia
More informationDesign of Lateral Load Resisting Frames Using Steel Joists and Joist Girders
1431 Design of Lateral Load Resisting Frames Using Steel Joists and Joist Girders Authors: Perry S. Green, Technical Director, Steel Joist Institute, 196 Stonebridge Drive Unit 1, Myrtle Beach, SC, psgreen@steeljoist.org
More informationDesign of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column
Design of reinforced concrete columns Type of columns Failure of reinforced concrete columns Short column Column fails in concrete crushed and bursting. Outward pressure break horizontal ties and bend
More informationSeismic performance evaluation of an existing school building in Turkey
CHALLENGE JOURNAL OF STRUCTURAL MECHANICS 1 (4) (2015) 161 167 Seismic performance evaluation of an existing school building in Turkey Hüseyin Bilgin * Department of Civil Engineering, Epoka University,
More informationEARTHQUAKE DESIGN OF BUILDINGS
GAP.2.0.9 A Publication of Global Asset Protection Services LLC EARTHQUAKE DESIGN OF BUILDINGS INTRODUCTION Buildings in many areas of the world are susceptible to damage from moderate to severe earthquakes.
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationEVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST
EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST Abstract Camelia SLAVE University of Agronomic Sciences and Veterinary Medicine of Bucharest, 59 Marasti
More information1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
More informationCE591 Lecture 8: Shear Walls
CE591 Lecture 8: Shear Walls Introduction History, examples Benefits Disadvantages Plate Girder Analogy Behavior of Special Plate Shear Walls (SPSW) Design of SPSW Important considerations Special Plate
More informationEARTHQUAKE INDUCED AMPLIFIED LOADS IN STEEL INVERTED V- TYPE CONCENTRICALLY BRACED FRAMES
EARTHQUAKE INDUCED AMPLIFIED LOADS IN STEEL INVERTED V- TYPE CONCENTRICALLY BRACED FRAMES Bora Akşar 1, Selçuk Doğru 2, Jay Shen 3, Ferit Cakir 4, Bulent Akbas 5 1 Res.Asst,, Gebze Technical University,
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More informationNATURAL PHENOMENA HAZARDS DESIGN AND EVALUATION CRITERIA FOR DEPARTMENT OF ENERGY FACILITIES
TS NOT MEASUREMENT SENSITIVE DOE-STD-1020-2002 January 2002 DOE STANDARD Superseding DOE-STD-1020-94 April 1994 NATURAL PHENOMENA HAZARDS DESIGN AND EVALUATION CRITERIA FOR DEPARTMENT OF ENERGY FACILITIES
More informationPerforated Shearwall Design Method 1
Perforated Shearwall Design Method 1 Philip Line, P.E., Bradford K. Douglas, P.E., American Forest & Paper Association, USA Abstract Wood frame shearwalls are traditionally designed using full-height shearwall
More informationBasics of Reinforced Concrete Design
Basics of Reinforced Concrete Design Presented by: Ronald Thornton, P.E. Define several terms related to reinforced concrete design Learn the basic theory behind structural analysis and reinforced concrete
More informationEarthquakes and Data Centers
7x24 Exchange Fall Symposium September 11, 2013 Hilton Bellevue Andrew W. Taylor, Ph.D., S.E., FACI Earthquake Hazards 2 September 11, 2013 1 Cascadia Earthquake Sources Figure Credit: Craig Weaver, Pacific
More informationComputer Program for the Analysis of Loads On Buildings. Using the ASCE 7-93 Standard. Stephen E. Browning. Master of Engineering.
Computer Program for the Analysis of Loads On Buildings Using the ASCE 7-93 Standard Minimum Design Loads for Buildings and Other Structures by Stephen E. Browning Report submitted to the Faculty of Virginia
More informationREINFORCED CONCRETE. Reinforced Concrete Design. A Fundamental Approach - Fifth Edition. Walls are generally used to provide lateral support for:
HANDOUT REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition RETAINING WALLS Fifth Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering
More informationTechnical Assignment 2 TABLE OF CONTENTS
2 TABLE OF CONTENTS Executive Summary...3 Introduction..5 Gravity Loads......6 Design Codes......7 Materials..8 Existing Structural System.. 10 Existing Floor System 15 Alternate Floor Framing Systems...17
More informationCritical Facility Round Table
Critical Facility Round Table October 16, 2003 San Francisco Seismic Risk for Data Centers David Bonneville Senior Principal Degenkolb Engineers San Francisco, California Presentation Outline Seismic Risk
More informationSEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE
International Journal of Advanced Research in Biology Engineering Science and Technology (IJARBEST) Vol., Issue, April 1 SEISMIC ANALYSIS AND RETROFITTING OF R.C.C STRUCTURE M.R.NAVANEETHA KRISHNAN 1,
More informationDesigning a Structural Steel Beam. Kristen M. Lechner
Designing a Structural Steel Beam Kristen M. Lechner November 3, 2009 1 Introduction Have you ever looked at a building under construction and wondered how the structure was designed? What assumptions
More informationReport on. Wind Resistance of Signs supported by. Glass Fiber Reinforced Concrete (GFRC) Pillars
Report on Wind Resistance of Signs supported by Glass Fiber Reinforced Concrete (GFRC) Pillars Prepared for US Sign and Fabrication Corporation January, 2006 SUMMARY This study found the attachment of
More informationDESIGN DRIFT REQUIREMENTS FOR LONG-PERIOD STRUCTURES
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 3292 DESIGN DRIFT REQUIREMENTS FOR LONG-PERIOD STRUCTURES Gary R. Searer 1 and Sigmund A. Freeman 2 SUMMARY
More informationSECTION 7 Engineered Buildings Field Investigation
SECTION 7 Engineered Buildings Field Investigation Types of Data to Be Collected and Recorded A field investigator looking at engineered buildings is expected to assess the type of damage to buildings.
More informationDraft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI 318-14
Draft Table of Contents Building Code Requirements for Structural Concrete and Commentary ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318 14) Chapter 1 General 1.1 Scope of ACI 318
More informationPage & Turnbull imagining change in historic environments through design, research, and technology
DCI+SDE STRUCTURAL EVALUATIONS OFFICE BUILDING, TOOL SHED & WATER TANK, AND BLACKSMITH & MACHINE SHOP BUILDINGS SAN FRANCISCO, CALIFORNIA [14290] PRIMARY PROJECT CONTACT: H. Ruth Todd, FAIA, AICP, LEED
More informationOptimum proportions for the design of suspension bridge
Journal of Civil Engineering (IEB), 34 (1) (26) 1-14 Optimum proportions for the design of suspension bridge Tanvir Manzur and Alamgir Habib Department of Civil Engineering Bangladesh University of Engineering
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationASSESSMENT AND RETROFITTING OF EXISTING RC BUILDINGS IN VIETNAM IN TERMS OF EARTHQUAKE RESISTANCES
GEM-SEA Workshop on Seismic Vulnerability of Buildings Nanyang Technological University, Singapore 1 st July 2013 ASSESSMENT AND RETROFITTING OF EXISTING RC BUILDINGS IN VIETNAM IN TERMS OF EARTHQUAKE
More informationresearch report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute
research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 2006 American Iron and Steel Institute Residential Hip Roof Framing Using Cold-Formed Steel Members i
More informationSTRUCTURAL DESIGN CHAPTER 16
CHAPTER 16 STRUCTURAL DESIGN SECTION 1601 GENERAL 1601.1 Scope. The provisions of this chapter shall govern the structural design of buildings, structures and portions thereof regulated by this code. SECTION
More informationHow To Design A Post Tensioned Deck For A Building
SAMUEL ÁVILA STRUCTURAL OPTION FACULTY CONSULTANT: THOMAS BOOTHBY UNIVERSITY OF CENTRAL FLORIDA S ACADEMIC VILLAGES ORLANDO, FL THESIS PROPOSAL EXECUTIVE SUMMARY DECEMBER 12, 2005 Introduction: The University
More informationREVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC BUILDINGS IN JAPAN
10NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska REVISION OF GUIDELINE FOR POST- EARTHQUAKE DAMAGE EVALUATION OF RC
More informationChapter. Earthquake Damage: Types, Process, Categories
3 Chapter Earthquake Damage: Types, Process, Categories Earthquakes leave behind a trail of damage and destruction. People s lives are affected by the loss of loved ones, destruction of property, economic
More informationSeismic Design of Cast-in-Place Concrete Special Structural Walls and Coupling Beams
NIST GCR 11-917-11REV-1 NEHRP Seismic Design Technical Brief No. 6 Seismic Design of Cast-in-Place Concrete Special Structural Walls and Coupling Beams A Guide for Practicing Engineers Jack P. Moehle Tony
More informationSeismic Design of Steel Special Moment Frames:
NIST GCR 09-917-3 NEHRP Seismic Design Technical Brief No. 2 Seismic Design of Steel Special Moment Frames: A Guide for Practicing Engineers Ronald O. Hamburger Helmut Krawinkler James O. Malley Scott
More informationSEISMIC RETROFITTING OF STRUCTURES
SEISMIC RETROFITTING OF STRUCTURES RANJITH DISSANAYAKE DEPT. OF CIVIL ENGINEERING, FACULTY OF ENGINEERING, UNIVERSITY OF PERADENIYA, SRI LANKA ABSTRACT Many existing reinforced concrete structures in present
More information6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
More informationSECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED
SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED NOTE: MOMENT DIAGRAM CONVENTION In PT design, it is preferable to draw moment diagrams
More informationSEISMIC APPROACH DESIGN COMPARISON BETWEEN
IABSE ANNUAL MEETING, LONDON, 19 TH SEPTEMBER 2011 SEISMIC APPROACH DESIGN COMPARISON BETWEEN IBC AND ITALIAN DM2008 Ing. Luca Zanaica Senior Structural Engineer Ing. Francesco Caobianco Senior Structural
More informationDesign of Cold-Formed Steel Shear Walls
DESIGN GUIDE 2 Design of Cold-Formed Steel Shear Walls March 1998 The following publication was developed by R.L. Brockenbrough & Associates for the American Iron and Steel Institute (AISI), In the production
More information4A6(1) Case Study Hartford Arena Roof Collapse Group 11. 4A6(1) Case Study. Group 11: Hartford Arena Roof Collapse
4A6(1) Case Study Group 11: Hartford Arena Roof Collapse Date: Authors: 21/10/2011 Seán Keane Eoin Norton Stephen Dent- Neville Figure 1: Image of the collapsed roof Introduction The Hartford Arena was
More informationCSA S16-09 Design of Steel Structures Canada
CSA S16-09 Design of Steel Structures Canada Ed Whalen, P.Eng CISC President CSA S16-09 1 CSA Standard S16-09 Standard, Design of Steel Structures. Sets out minimum requirements used by engineers in the
More informationdetermining wind and snow loads for solar panels America s Authority on Solar
determining wind and snow loads for solar panels America s Authority on Solar Determining wind and snow loads for solar panels 1 introduction As one of the largest and most established vertically integrated
More informationFoundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
More informationARCH 331 Structural Glossary S2014abn. Structural Glossary
Structural Glossary Allowable strength: Nominal strength divided by the safety factor. Allowable stress: Allowable strength divided by the appropriate section property, such as section modulus or cross
More informationPROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)
APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL FIRE RESTORATION PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of
More informationDESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
More informationFire and Concrete Structures
Fire and Concrete Structures Authors: David N. Bilow, P.E., S.E., Director, Engineered Structures, Portland Cement Association 5420 Old Orchard Road, Skokie, IL 60077,Phone 847-972-9064, email: dbilow@cement.org
More informationContractor s Statement of Responsibility for Seismic-Force-Resisting Systems This form is to be filled out by the contractor.
SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17 2012 EDITION When Required All projects that require a SC licensed Architect or Engineer per SC Architectural and Engineering registration law. Overview The
More informationSection 5A: Guide to Designing with AAC
Section 5A: Guide to Designing with AAC 5A.1 Introduction... 3 5A.3 Hebel Reinforced AAC Panels... 4 5A.4 Hebel AAC Panel Design Properties... 6 5A.5 Hebel AAC Floor and Roof Panel Spans... 6 5A.6 Deflection...
More informationSTRUCTURAL DESIGN CHAPTER 16
CHAPTER 16 STRUCTURAL DESIGN SECTION 1601 GENERAL 1601.1 Scope. The provisions of this chapter shall govern the structural design of buildings, structures and portions thereof regulated by this code. SECTION
More informationHow to Design Helical Piles per the 2009 International Building Code
ABSTRACT How to Design Helical Piles per the 2009 International Building Code by Darin Willis, P.E. 1 Helical piles and anchors have been used in construction applications for more than 150 years. The
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More informationDesign Parameters for Steel Special Moment Frame Connections
SEAOC 2011 CONVENTION PROCEEDINGS Design Parameters for Steel Special Moment Frame Connections Scott M. Adan, Ph.D., S.E., SECB, Chair SEAONC Structural Steel Subcommittee Principal Adan Engineering Oakland,
More informationReview of Code Provisions on Design Seismic Forces for Liquid Storage Tanks
Document No. :: IITK-GSDMA-EQ1-V1. Final Report :: A - Earthquake Codes IITK-GSDMA Project on Building Codes Review of Code Provisions on Design Seismic Forces for Liquid Storage Tanks by Dr. O. R. Jaiswal
More informationDESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia
DESIGN OF SLABS Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia Introduction Types of Slab Slabs are plate elements
More informationDetailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
More informationConcrete Design Manual
The Reinforced Concrete Design Manual In Accordance with ACI 318-11 SP-17(11) Vol 2 ACI SP-17(11) Volume 2 THE REINFORCED CONCRETE DESIGN MANUAL in Accordance with ACI 318-11 Anchoring to concrete Publication:
More informationFormwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
More informationSteel Design Guide Series. Column Base Plates
Steel Design Guide Series Column Base Plates Steel Design Guide Series Column Base Plates Design of Column Base Plates John T. DeWolf Professor of Civil Engineering University of Connecticut Storrs, Connecticut
More informationCOLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP
COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP 30 x45 bay provides maximum tenant flexibility and increases leasing marketability By David E. Eckmann AIA, S.E. P.E. SURGING DEMANDS FOR RENTABLE OFFICE
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationMEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as
More informationProtecting data centers from seismic activity Understanding enclosure standards is critical to protecting equipment
Protecting data centers from seismic activity Understanding enclosure standards is critical to protecting equipment Author: Joel Young, engineer at Crenlo Abstract In the event of an earthquake, the type
More informationDESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS
8601 North Black Canyon Highway Suite 103 Phoenix, AZ 8501 For Professionals Engaged in Post-Tensioning Design Issue 14 December 004 DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS by James D. Rogers 1 1.0
More informationSEISMIC DESIGN CRITERIA
Chapter 11 SEISMIC DESIGN CRITERIA 11.1 GENERAL 11.1.1 Purpose. Chapter 11 presents criteria for the design and construction of buildings and other structures subject to earthquake ground motions. The
More informationINTRODUCTION TO BEAMS
CHAPTER Structural Steel Design LRFD Method INTRODUCTION TO BEAMS Third Edition A. J. Clark School of Engineering Department of Civil and Environmental Engineering Part II Structural Steel Design and Analysis
More informationJoist. Reinforcement. Draft 12/7/02
Joist Reinforcement Draft 12/7/02 1 JOIST REINFORCING The purpose of this CSD Design Aid is to provide procedures and suggested details for the reinforcement of open web steel joists. There are three basic
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationNew approaches in Eurocode 3 efficient global structural design
New approaches in Eurocode 3 efficient global structural design Part 1: 3D model based analysis using general beam-column FEM Ferenc Papp* and József Szalai ** * Associate Professor, Department of Structural
More informationSTRUCTURAL DESIGN CHAPTER 16
CHAPTER 16 STRUCTURAL DESIGN SECTION 1601 GENERAL 1601.1 Scope. The provisions of this chapter shall govern the structural design of buildings, structures and portions thereof regulated by this code. Exception:
More informationPERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY
Paper No. 682 PERFORMANCE BASED SEISMIC EVALUATION AND RETROFITTING OF UNSYMMETRICAL MEDIUM RISE BUILDINGS- A CASE STUDY Jimmy Chandra, Pennung Warnitchai, Deepak Rayamajhi, Naveed Anwar and Shuaib Ahmad
More information