1 VE VXG Series Electronic Three-way s Technical Instructions Document No P25 VE VXG-1 Description The VE VXG electronic three-way valve controls the flow of water or glycol solutions. The electronic actuator requires a 24 Vac supply and receives a 0 to 10 Vdc control signal to control the 7/32-inch (5.5 mm) nominal stroke valve. Features Maintenance free actuator with reversible motor Application Selector plug on actuator permits selection of linear or equal percentage flow characteristics Reduced seat diameter produces reduced Cv (Kvs) in 1/2-inch valve bodies 0 to 10 Vdc or 0 to 1000 ohms signal input Position output signal 0 to 10 Vdc Available with union or sweat end connections (1/2 and 3/4-inch) Double O-ring packing with Teflon wiper Manual override knob with indication of stroke allows for repositioning of the valve in power-off conditions (SQS65U only) Spring return closes flow port in power-off condition (SQS65.5U only) The VE VXG valve can be used as a control and shutoff valve in small to medium HVAC installations for hot water and chilled water applications. Use only as a mixing valve. Use in closed circuits only. NOTE: This valve is not designed for steam applications. See body specifications for details. Product Numbers and Ordering Information Order the valve and actuator separately. See Table 1 for product information.
2 Technical Instructions VE VXG Electronic Three-way s Nominal Size Inches (mm) Cv (Kvs) Body only with External Threads Product Number Union Table 1. Product Information. Sweat Actuator Product Number Non- Spring Return Spring Return 0.5 (15) 0.47 (0.40) VXG VXG U VXG S SQS65U SQS65.5U (15) 0.74 (0.63) VXG VXG U VXG S SQS65U SQS65.5U (15) 1.17 (1.0) VXG VXG U VXG S SQS65U SQS65.5U (15) 1.87 (1.6) VXG VXG U VXG S SQS65U SQS65.5U (15) 2.92 (2.5) VXG VXG U VXG S SQS65U SQS65.5U (15) 4.68 (4) VXG VXG U VXG S SQS65U SQS65.5U (20) 7.37 (6.3) VXG VXG U VXG S SQS65U SQS65.5U (25) 11.7 (10) VXG VXG U SQS65U SQS65.5U (32) 18.7 (16) VXG VXG U SQS65U SQS65.5U (40) 29 (25) VXG VXG U SQS65U SQS65.5U 100 Max P * = Maximum recommended differential pressure for modulating service. Specifications Actuator Power Requirements Functional Operation Control Characteristics Spring and Non-Spring Return Range- Ability Operating Voltage 60 Hz 24 Vac, +20%, -15% 50 Hz 24 Vac, ±20% Power Consumption SQS65U 4.5 VA SQS65.5U 7 VA Running Time At 60 Hz 30 seconds At 50 Hz 35 seconds Close-Off psig (kpa) 43.5 (300) 29 (200) 14.5 (100) Spring Return (SQS65.5U only) 8 seconds Nominal Stroke 7/32-inch (5.5 mm) Nominal Force 67 lb (300 N) Control Signal (Y) Voltage 0 to 10 Vdc Current 0.1 ma Input Impedance 100K ohms Control Signal (R) Resistance 0 to 1000 ohms Position Output (U) Voltage 0 to 10 Vdc Current 0.5 ma maximum Flow Characteristic Linear or equal percentage Max P * psig (kpa) 43.5 (300) 29 (200) 14.5 (100) Page 2
3 VE VXG Electronic Three-way s Specifications, Continued Technical Instructions Environmental Ambient Temperature Operating 5 to 122 F (-15 to 50 C) Conditions Transport and storage -13 to 149 F (-25 to 65 C) Agency Approvals UL UL873 C-UL Certified to Canadian Standards CSA C22.2 No Physical Characteristics Weight SQS65U SQS65.5U 1.1 lb (0.5 kg) 1.3 lb (0.6 kg) Dimensions See Figure 8 Composition Body Style Globe Body Bronze Connections Union with brass nut, composite gasket, forged bronze tail piece with internal NPT or Sweat end for use in 7/8-inch O.D. copper tubing Trim Upper Seat 1/2-inch and 3/4-inch Stainless Steel 1-inch to 1-1/2 inch Bronze Lower Seat Bronze Packing Double O-ring Body Rating ANSI 125 (PN 16) Operating Conditions Physical Characteristics Line Size/Capacity See Tables 1 and 2 Medium Water, glycol to 50% Rangeability See Table 1 Flow Characteristics II to I and III to I Field selectable. See Start-up section. Leakage Rate 0.02% of Cv Medium Temperature 36 to 248 F (2 to 120 C) Maximum Inlet Pressure 232 psig (1600 kpa) Maximum Pressure Differential for Modulating Service See Table 1 Close-Off Pressure See Table 1 Weight See Figure 8 Dimensions See Figure 8 Page 3
4 Technical Instructions VE VXG Electronic Three-way s Table 2. Maximum Water Capacity US Gallons per Minute. Pressure Differential (psi) 1 Kvs Cv 1/2 (15) 0.47 (0.40) /2 (15) 0.74 (0.63) /2 (15) 1.17 (1.0) /2 (15) 1.87 (1.6) /2 (15) 2.92 (2.5) /2 (15) 4.68 (4.0) /4 (20) 7.37 (6.3) (25) 11.7 (10) /4 (32) 18.7 (16) /2 (40) 29 (25) Warning/Caution Notations WARNING: CAUTION: Personal injury/loss of life may occur if you do perform a procedure as specified. Equipment damage may occur if you do not perform a procedure as specified. Operation The arrow on the valve indicates the direction of flow. As a mixing valve, the direction of flow is always from II (A) to I (AB). See Figure 1. Figure 1. VXG Direction of Flow. With the valve stem down, the valve opens from II (A) to I (AB) and closes III (B) to I (AB). With the valve stem up, the valve closes from II (A) to I (AB) and opens III (B) to I (AB). An electronic motor actuator positions the valve. A continuous 0 to 10 Vdc signal controls the actuator. The valve provides a linear flow characteristic. A selector plug on the SQS actuator allows selection of linear or equal percentage flow characteristic. The valve stroke is proportional to the control signal with linear flow selected. See Figure 6. Page 4
5 VE VXG Electronic Three-way s Operation, Continued Technical Instructions A zero voltage control signal returns the valve to its 0 position. In the event of a power failure, the SQS65U holds its last position, and the SQS65.5U returns the valve to its fail-safe position. The position output 0 to 10 Vdc signal U produces position feedback to the field panel. An additive control input at R for 0 to 1000 ohms allows control by either a low temperature detector or a remote setting unit. Installation The valve assembly can be installed in the supply or return line. NOTE: For hot water installations, it is recommended to place the valve in the return line because the temperature is lower. Match the direction of flow with the symbol cast on the valve body. See Figure 1. Allow 8 inches (200 mm) of clearance for installation and service. Mount the assembly in any position except with the actuator beneath the valve. See Figure 2 for allowable mounting positions. CAUTION: Dirt in the piping system can cause valve problems. Before starting-up and troubleshooting the valve, make certain that the piping system is free of dirt and foreign particles. Figure 2. Mounting Positions. Before installing the actuator, use a protective plastic cap (Figure 1) to manually position the valve. The plastic cap opens up to 80% flow from II (A) to I (AB) and closes down to 20% flow from III (B) to I (AB). Port III (B) can not be completely closed using the plastic cap. NOTE: Do not discard the plastic cap. It may be needed during troubleshooting or for emergency valve operation. Page 5
6 Technical Instructions Wiring WARNING: VE VXG Electronic Three-way s On valve actuator wiring code, G is 24 Vac HOT, not ground. Figure 3. Terminal Connections in Actuator. G, G0 24 Vac operating voltage G = System potential G0 = System neutral Y 0 to 10 Vdc control signal R M U Input for 0 to 1000 ohms remote setting unit or low temperature detection unit Measuring neutral Output for 0 to 10 Vdc position indication Figures 4 and 5 show wiring diagrams for the APOGEE field panels. All units that connect to terminals Y and U, together with the SQS65U, must connect to the same G0. When wiring the position output to AI terminations, connect terminal U to SIG and terminal G0 to COM. The factory-fitted link across terminals R and M can be removed only if a unit connects between these terminals. Figure 4. Field Panel Series Wiring. Figure 5. Field Panel Parallel Wiring. Page 6
7 VE VXG Electronic Three-way s Technical Instructions Start-Up Remove the actuator cover and verify the selector plug is set for the desired flow characteristic. See Figure 6. Position A-C C-B Flow Characteristics Equal Percentage (Factory Setting) Linear Equal Percentage Linear O O A C B A C B V = Volumetric flow 1 to 100% YU = 0 to 10 Vdc control signal YR = 0 to 1000 ohm resistance signal Figure 6. Selector Plug Setting for Flow Characteristic. Troubleshooting Check wiring for appropriate connections (Figures 4 and 5). Check selector plug for proper flow characteristic. Check valve operation. Thread plastic valve cap (Figure 1) onto top of valve. Turn it to adjust valve position. Stem Packing Figure 7. VXG Construction. Service If either valve or actuator is inoperative, replace that unit. WARNING: To avoid personal injury, do not attempt to repair the valve. Page 7
8 Technical Instructions VE VXG Electronic Three-way s Dimensions Nominal Size 1/2 (15) 3/4 20) 1 (25) A AA B BB 3-15/16 (100) 3-15/16 (100) 4-5/32 (105) 1-1/4 (32) 4-5/32 (105) 1-1/2 (40) 5-1/8 (130) 5-13/16 (148) 5-29/32 (150) 6-5/16 (160) 6-11/16 (170) 7-13/16 (198) 1-31/32 (50) 1-31/32 (50) 2-1/16 (52.5) 2-1/16 (52.5) 2-9/16 (65) 2-29/32 (74) 2-15/16 (75) 3-5/32 (80) 3-3/8 (85) 3-29/32 (99) C Metric Thread G 1" 11/32 (8.5) G 1-1/4" 3/8 (9) G 1-1/2" 3/8 (9) G 2" 7/16 (11) G2-1/2" 1/4 D H J M N 7/16 (11) 2-1/2 (63) 3-1/16 (78) 3-3/16 (81) 3-7/16 (87.5) 3-9/16 (90.5) 2-3/32 (53) 2-11/16 (68) 2-25/32 (71) 3-1/16 (77.5) 3-3/16 (80.5) 1 (25) 1-1/4 (32) 1-1/2 (38) 1-7/8 (47) 2-3/32 (53) 1-5/8 (41) 1-31/32 (50) 2-5/32 (55) 2-3/4 (70) 2-31/32 (75) Figure 8. Dimensions for SQS65U Actuator and VXG 44. P NPT for Union S Solder Cup for Sweat Weight of lbs. (kg) 1/2" 7/8" 1.1 (0.50) 3/4" 7/8" 1.9 (0.85) 1" (1.20) 1-1/4" (1.60) 1-1/2" Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. APOGEE is a registered trademark of Other product or company names mentioned herein may be the trademarks of their respective owners Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Document No P25 Printed in the USA Page 8
Powers Controls TH 192 S Single Temperature Room Thermostat
Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional
More informationVG7000 Series Bronze Control Valves
VG7000 Series Bronze Control Valves Product Bulletin VG7000 Series Code No. LIT-977140 Issued November 15, 2013 Supersedes March 29, 2013 VG7000 Series Bronze Control Valves are designed primarily to regulate
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More information2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.
2012 Valve & Valve Actuator Catalog For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.com/hvac Our dynamic duos provide comprehensive control. Fast installation
More informationIntroduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac
Introduction Angle/Flared/Sequence/Changeover Service D-193 In this section, you will find flared, angled, sequence and changeover valves for use in service applications. D-194 Need additional assistance?
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More informationSKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
More information4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
More informationVG2000 Series Cast Iron Flanged Globe Valves
VG2000 Series ast Iron Flanged Globe Valves Installation Instructions Part No. 14-1161-106, Rev. Issued November 15, 2013 Supersedes June 15, 2007 pplications VG2000 Series ast Iron Flanged Globe Valves
More informationBaumann 24003 3 Way Bronze or Stainless Steel Control Valve
Product Bulletin D1039X012 24003 Valve Baumann 24003 3 Way Bronze or Stainless Steel Control Valve 3 Way Rugged Industrial Control Valve For Mixing and Diverting Applications The Baumann 24003 3 way control
More information2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
More informationPowers Controls TH 192 HC Heating/Cooling Room Thermostat
Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional
More informationDOUBLE SEAT BRONZE BODY HIGH CAPACITY
PS593DB HEAVY DUTY BRONZE GLOBE CONTROL VALVES DB DOUBLE SEAT BRONZE BODY HIGH CAPACITY 1, 1-1/4, 1-1/2, and 2 Union Ends ANSI Class 250 Body Rating ANSI Class II Close off Bronze or Stainless Steel Trim
More informationRC 195 Multiple Input Receiver-Controller
Document No. 129-230 RC 195 Multiple Input Receiver-Controller Product Description The RC 195 Multiple Input Receiver-Controller is a pneumatic instrument that can be used as a one input (DA or RA), two
More informationPOWERS CONTROL RC 195 Single Input Receiver-Controller
Document No. 155-119P25 RC 195-4 POWERS CONTROL RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,
More informationBaumann 24000 Little Scotty Bronze Control Valve
24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature
More informationTECHNICAL BULLETIN. Kämmer LinedFlow - 132000 Corrosive Application Valves. Experience In Motion FCD KMENTB3221-01 04/12
TECHNICAL BULLETIN Kämmer LinedFlow - 132000 Corrosive Application Valves FCD KMENTB3221-01 04/12 Experience In Motion Description ¼-inch NPT test port Large guided stem area Bellows seal eliminates stem
More information% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power
.55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More informationBERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features
Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationValve and Valve Actuator Selection Guide
www.sbt.siemens.com/hvp/components Building Technologies Building Technologies Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel 847 215 1000 Siemens Building
More informationSubmersion/Insertion Toroidal Sensor
Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS
More informationAssisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
More informationSpira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationKämmer Series 185000 Laboratory Valves
flowserve.com Kämmer Series 185000 Laboratory Valves Description Kämmer microflow series 185000 / 285000 and 187000 / 287000 are ½" laboratory valves designed for precision controlling. The bodies in stainless
More informationTechnical Instructions Document No. 155-021P25 ET 141-5 September 28, 2004. ET 141 High Limit Control Thermostat. Description.
Document No. 155-021P25 ET 141-5 ET 141 High Limit Control Thermostat Description Application The ET 141 high limit control thermostat is duct mounted and has a rigid bulb, bi-metal rod and tube construction.
More information2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications
Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?
More informationToroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
More informationTechnote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.
Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on
More informationI nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
More informationOPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...
OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS INTRODUCTION...1 Scope...1 Description...1 Valve Identification...2 1.0 VALVE INSTALLATION...2 2.0 VALVE MAINTENANCE...3 Actuator Disassembly...3
More information2- and 3-port valves with flanged connections, PN 10
4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey
More informationSeated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange
Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The
More informationVSO MAX HP High Flow Proportional Valve
VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties
More informationRAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationXE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY
XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationP70, P72, and P170 Series Controls for Dual Pressure Applications
P70, P72, and P170 Series Controls for Dual Pressure Applications Product Bulletin Code No. LIT-125455 Issued August 30, 2012 Supersedes September 1, 2000 The P70, P72, and P170 controls for dual pressure
More informationS GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR
MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,
More informationElectrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)
Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports
More informationVC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES
VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge
More informationHVAC Valves and Actuators Catalogue
HVAC Valves and Actuators Catalogue Issue: September 2008 Make the most of your energy TAC the Single Source for all your Valve and Actuator Needs This catalogue presents the comprehensive HVAC Valve and
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationFisher 657 and 667 Diaphragm Actuators
657 and Actuators Product Bulletin Fisher 657 and Diaphragm Actuators Fisher 657 and spring-opposed diaphragm actuators position the valve plug in the valve in response to varying controller or valve positioner
More informationMP8000 Series Pneumatic Valve Actuators
14-1161- 9, Rev. A Technical Bulletin MP8000 Issue Date March 2016 MP8000 Series Pneumatic Valve Actuators Pre-Assembly Details Page 3 MP8000 Actuator Components 3 Tools Required to Assemble an MP8000
More informationCCI 100 DPC DRAG Wellhead Production Choke Valve
CCI 100 DPC DRAG Wellhead Production Choke Valve 2 Severe service DRAG choke valve delivers precise wellhead pressure control with superior reliability and life. Improves well production time Enhances
More informationFloat and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationAir Conditioning & Refrigeration Master Catalog. Catalog CIC-2003-1/USA April 2003
Air Conditioning & Refrigeration Master Catalog Catalog CIC-2003-1/USA April 2003 Table of Contents Table of Contents Service Valves Frontseating Valves... page 115 RB01 Series Ball Valves... page 117
More informationTYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationFlow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting
Data sheet Flow controller with integrated control valve (PN 16, 5, 40*) AFQM, AFQM 6 - return and flow mounting Description AFQM 6 DN 40, 50 AFQM DN 65-15 AFQM DN 150-50 AFQM(6) is a self-acting flow
More informationBaumann 87000 Flexsleev Sanitary Control Valve
Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found
More informationBURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS
BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief
More informationTABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationV47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
More informationBERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
More informationVALVES FOR REFRIGERATING SYSTEMS
VALVES FOR REFRIGERATING SYSTEMS FROM QUALITY OUR NATURAL DEVELOPMENT Achieved the goal of fi fty years working in the industry of Refrigeration and Air Conditioning, Castel Quality Range of Products is
More informationType 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
More informationREGULATORS D& HD Series
Watson McDaniel reserves the right to change the designs and/or materials of its products out notice. 2002 Watson McDaniel Company Ductile Iron body - HD Series Full port strainer & blowdown valve on pilot
More informationType 3353 Angle Seat Valve
Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat
More informationSITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationSeries 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
More informationProduct Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description
Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR
More informationModel 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
More informationRADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS
RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS MANIFOLD ASSEMBLIES ONE-PIPE Compatible with most radiators on the market, this pre-assembled manifold for one-pipe radiator systems delivers balancing
More informationSelf-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationINSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
More informationModel 111 Mass Flow Instruments
111 Mass Instruments Porter Mass products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design
More informationGS-General Service Control Valves
GS-General Service Control Valves GS-General Service Valves The GS-General Service Valves continue Copes-Vulcan s tradition of designing and manufacturing control valves that provide both exceptional service
More informationIOM SERIES 820-E/P Electro-Pneumatic Positioner
FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationResidential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
More information3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
More informationThermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16) Description RAVK can be combined with: - 2-way valves RAV-/8, VMT-/8, VMA, or - 3-way valves
More informationOWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
More informationP66 Series Electronic Fan Speed Controls
P66 Series Electronic Fan Speed Controls Product Bulletin Code No. LIT-125465 Issued September 30, 2009 Supersedes March 23, 2006 The P66 Series Electronic Fan Speed Controls are refrigerant pressure actuated,
More informationQLM and QLD Series Three-port Control Valves
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationTHERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
More informationFisher 377 Trip Valve
377 Trip Valve Product Bulletin Fisher 377 Trip Valve Fisher 377 pressure sensing trip valves are for control applications where a specific valve/actuator action is required when supply pressure falls
More informationButterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationTA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.
TA-FUS1ON Fully adjustable Kvs control and balancing valves. That s just two good. Supported by the Reece hvac-r network. Through our 36 stores around Australia, Reece hvac-r is committed to supporting
More informationThermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)
- for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special
More informationFisher D3 Control Valve
D3 Valve Product Bulletin Fisher D3 Control Valve The Fisher D3 control valve is a compact, rugged valve designed for on/off or throttling control, and utilizes FloPro technology, using either pneumatic
More informationMBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationThe Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationneedle valves Needle Valves Index At a Glance 1
Needle Valves Index At a Glance 1 1700 Series 5 Forged Body, Integral Bonnet Needle Valves 2100 Series 8 Bar Stock, Screwed Bonnet Needle Valves 2200 Series 12 Bar Stock, Screwed Bonnet Needle Valves 2219
More informationSelf-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F
Self-operated Temperature Regulators Type 1 to Type 9 PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Edition April 2012 Information Sheet T 2010 EN Self-operated
More informationValve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)
Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL
More informationPNEUMATIC CONTROLS Selection and Description
PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent
More informationTechnical Data. Installation
Technical Services: Tel: (800) 81-91 / Fax: (800) 791-5500 Model 51 (1) Riser Manifold 1-1/ thru 6 Inch (DN40 thru DN150) For NFPA 1 Sprinkler Systems General Description The Figure 51 (1) Riser Manifolds
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More information