Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
|
|
- Richard Dean
- 7 years ago
- Views:
Transcription
1 . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, , 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X Number of poles 1, 3, 4, 3, 4 1, 3, 4 1, 3, 4 3, 4, 3, 4, 3, 4, 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 3, 4 Breaker Capacity (ka rms) Vac Hz NEMA, 40 Vac UL, CSA 480 Vac Vac /50 Vdc IEC Vac I cu I cs Vac I cu I cs Vac I cu I cs /50 Vdc 5 I cu I cs Ampere range A A A Trip Units F = Fixed A = Adjustable T = Thermal M = Magnetic Thermal magnetic FT-FM AT-FM 1 15 amperes is the maximum UL and CSA rating for the EG. 630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA listed rating for the LG. 3 Breaker type C, U and X are current limiting per UL EG breaker rated 600/347 Vac. 5 Two poles in series Vdc only for single-pole breakers. 7 Not suitable for DC application. Four-pole ground fault not available. FT-AM AT-AM Electronic (Digitrip RMS 310) FT-AM AT-AM Electronic (Digitrip RMS 310) Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI LSG LSIG Utilization category A A A A A A A A A A A A A A A A A A A A Volume 4 Circuit Protection CA E January V4-T-9
2 . Frames NG and RG 1 NG 1600 ampere frame is not UL or CSA listed. Not KEMA-KEUR listed. 3 IEC H.5 Annex H is not KEMA-KEUR tested. 4 Not suitable for DC application. Four-pole ground fault not available. 5 Available only on Digitrip 610 and 910 trip units. NG Maximum rated current (amperes) 800, , , , 000, , 000, 500 Breaker type S H C S U H C Number of poles, 3, 4, 3, 4, 3, , 4 3, 4 Breaker Capacity (ka rms) AC Hz NEMA, 40 Vac UL, CSA 480 Vac Vac IEC Vac I cu I cs Vac I cu I cs Vac I cu I cs Vdc I cu I cs Ampere range A A A 1600A 800A A A Trip units Electronic Electronic (Digitrip RMS 310+) (Digitrip RMS 310+, 610 and 910) Interchangeable Built-in Electronic 4 LI 5 5 LS LSI LIG 5 5 LSG LSIG ALSI ALSIG Utilization category A A A A A A A RG V4-T-10 Volume 4 Circuit Protection CA E January 013
3 . General Specifications All Frames 1 15 amperes is the maximum UL and CSA rating for the EG. 630 amperes is not a UL or CSA listed rating. 600 amperes is the maximum UL and CSA rating for the LG amperes is the maximum UL and CSA rating for the NG. 4 Thermal overload release set to the lower value. 5 Thermal overload release set to the upper value. 6 Not suitable for DC switching. EG JG LG NG RG Maximum rated current I n depending on the version 160A 1 50A 400, 630A 800, 100, 1600A , 000, 500A Rated insulation voltage U, according to IEC Main conducting paths 500 Vac 750 Vac 750 Vac 750 Vac 750 Vac Auxiliary circuits 500 Vac 690 Vac 690 Vac 690 Vac 690 Vac Rated impulse withstand voltage U imp Main conducting paths 6 kv 8 kv 8 kv 8 kv 8 kv Auxiliary circuits 4 kv 4 kv 4 kv 4 kv 4 kv Rated operational voltage U e IEC 415 Vac 690 Vac 690 Vac 690 Vac 690 Vac NEMA 600Y/347 Vac 600 Vac 600 Vac 600 Vac 600 Vac UL and CSA listed Yes 1 Yes Yes Yes 3 Yes Permissible ambient temperature 0 to 70 C 0 to 70 C 0 to 70 C 5 to 60 C 5 to 60 C Permissible load for various ambient temperatures close to the circuit breaker, related to the rated current of the circuit breaker Circuit breakers for plant protection At 40 C 100% 100% 100% 100% 100% 100% 100% 100% At 50 C 96% 9% 96% 94% 96% 91% 91% 91% At 55 C 93% 87% 94% 90% 93% 86% 85% 85% At 60 C 91% 83% 9% 87% 90% 8% 81% 81% At 70 C 86% 73% 88% 80% 84% 70% Circuit breakers for motor protection At 40 C 100% 100% At 50 C 100% 100% At 55 C 100% 100% At 60 C 100% 100% At 70 C 90% 90% Circuit breakers for starter combinations and isolating circuit breakers At 40 C 100% 100% 100% 100% 100% At 50 C 100% 100% 100% 91% 91% At 55 C 96% 96% 95% 85% 85% At 60 C 91% 8% 90% 81% 81% At 70 C 86% 88% 84% Rated short-circuit breaking capacity (DC) Not for circuit breakers for motor protection (Time constant t = 10 rms) Two conducting paths in series 4 ka max. 4 ka max. 4 ka max. 6 6 For EG to LG up to 50 Vdc NEMA (time constant t = 8 rms) Two conducting paths in series 50 Vdc 4 ka max. 4 ka max. 4 ka max. 6 6 Volume 4 Circuit Protection CA E January V4-T-11
4 . All Frames, continued EG JG LG NG RG Main switch characteristics according to IEC in combination with lockable rotary drives Yes Yes Yes Yes Yes Rated short circuit breaking capacity according to For rated short circuit breaking capacity, see Page V4-T-9. IEC (at AC 50/60 Hz) Endurance (operating cycles) 10,000 10,000 8,000 3,000 3,000 Maximum switching frequency 300 1/h 40 1/h 40 1/h 60 1/h 60 1/h Conductor cross sections and terminal types for main conductors Box terminals Box terminals Box terminals Flat bar terminals Flat bar terminals Flat bar terminals Solid or stranded.5 to 95 mm 50 to 150 mm 95 to 40 mm Finely stranded with end sleeve.5 to 50/70 mm 35 to 10 mm 70 to 150 mm Busbar 600A Optional Optional Tightening torque for box terminals 5.6 Nm 0 Nm 4 Nm 31 Nm 31 Nm Tightening torque for busbar connection pieces 5.6 Nm 15 Nm 30 Nm 6 Nm 50 Nm 0 Nm Conductor cross sections for auxiliary circuits with terminal connection or terminal strip Solid 0.75 to.5 mm 0.75 to.5 mm 0.75 to.5 mm Up to x4 mm Up to x4 mm Finely stranded with end sleeve 0.75 to.5 mm 0.75 to.5 mm 0.75 to.5 mm Up to x.5 mm Up to x.5 mm With brought-out cable ends 0.8 (AWG 18) mm 0.8 (AWG 18) mm 0.8 (AWG 18) mm 0.8 (AWG 18) mm Tightening torque for fitting screws 0.8 to 1.4 Nm 0.8 to 1.4 Nm 0.8 to 1.4 Nm 0.8 to 1.4 Nm Power loss per circuit breaker at maximum rated current l n (the power losses of the undervoltage releases ( r releases) must be observed if necessary) at three-phase symmetrical load) 400A: 600A: For plant protection 40W 45W 65W 10W 87/10W 0/70/400W As isolating circuit breaker 40W 45W 65W 10W 87/10W 0/70/400W For starter combinations 40W 45W 65W 10W For motor protection 45W 65W 10W Permissible mounting position 90 Arc spacing suitable for reverse-feed applications Yes (except HMCPE) Yes Yes Yes Yes Auxiliary Switches Rated thermal current l th 6A 6A 6A 6A 6A Rated making capacity 0A 0A 0A 0A 0A AC-14 AC-14 AC-14 AC-15 AC-15 Rated operational voltage 30/400/600V 30/400/600V 30/400/600V 600V 600V Rated operational current 6/3/0.5A 6/3/0.5A 6/3/0.5A 6A 6A DC-13 DC-13 Rated operational voltage 15/50V 15/50V 15/50V 15/50V 15/50V Rated operational current 0.5/0.15A 0.5/0.15A 0.5/0.15A 0.5/0.5A 0.5/0.5A Backup fuse 6/4/4A (4) 6/4/4A (4) 6/4/4A (4) 6/4/4A (4) 6/4/4A Miniature circuit breaker 6/4A 6/4A 6/4A 6/4A 6/4A V4-T-1 Volume 4 Circuit Protection CA E January 013
5 . All Frames, continued EG JG LG NG RG Releases Undervoltage releases ( r releases) Response voltage: Drop (breaker tripped) U s 35 70% 35 70% 35 70% 35 70% 35 70% Pickup (breaker may be switched on) U s % % % % % Power consumption in continuous operation at: 50/60 Hz 1 Vac 1.9 VA.9 VA 50/60 Hz 4 Vac 0.7 VA 3.9 VA 3.9 VA.4 VA 3.1 VA 50/60 Hz Vac VA VA VA VA VA 50/60 Hz Vac VA VA VA VA VA 50/60 Hz Vac VA VA VA VA VA 50/60 Hz Vac. 3.9 VA VA VA VA VA 50/60 Hz Vac VA VA VA 1 Vdc.6W 3.4W 4 Vdc 0.70W 3.1W 3.1W 3.6W 4.3W Vdc W.0 3.1W.0 3.1W W W Vdc W 1.6.W 1.6.W.9 3.6W W 0 50 Vdc W 3.1 4W 3.1 4W W W Maximum opening time 50 ms 50 ms 50 ms 6 ms 6 ms Shunt Trips Shunt trips ( f releases) Response voltage: Pickup (breaker tripped) U s % % % % % Power consumption in (short time) at: 50/60 Hz 4 Vac VA VA VA VA 61 VA 50/60 Hz Vac VA VA VA 4 50 VA VA 50/60 Hz Vac 50/60 Hz Vac VA VA VA VA VA 50/60 Hz Vac VA VA VA VA 50/60 Hz Vac VA 50/60 Hz Vac VA VA 19 4 VA VA 1 4 Vdc 9 10W W W W 396W Vdc W W W 67 10W W Vdc 99 11W W W W W 0 50 Vdc 40 58W 40 58W 46 55W W Maximum load duration Interrupts automatically Interrupts automatically Interrupts automatically Interrupts automatically Interrupts automatically Maximum opening time 50 ms 50 ms 50 ms 6 ms 6 ms Molded Case Switch (with High Magnetic Trip) Unfused kaic at 480 Vac (415 Vac) 65 (70) 65 (70) 65 (70) 65 (70) 65 (70) Self-protected, will trip above 150 for EG15; 1600 for EG /6300 1,500 0,000 Volume 4 Circuit Protection CA E January V4-T-13
6 . Dimensions and Weights Approximate Dimensions in Inches (mm) Frame EG, JG and LG EG JG LG H W D H W D H W D Single-pole 5.50 (139.7) 1.00 (5.4).99 (76.0) Two-pole 5.50 (139.7).00 (50.8).99 (76.0) 7.00 (177.8) 4.13 (105.0) 3.57 (87.4) Three-pole 5.50 (139.7) 3.00 (76.).99 (76.0) 7.00 (177.8) 4.13 (105.0) 3.57 (87.4) (58.0) 5.48 (140.0) 4.09 (104.0) Four-pole 5.50 (139.7) 4.00 (101.6).99 (76.0) 7.00 (177.8) 5.34 (135.6) 3.57 (87.4) (58.0) 7. (183.0) 4.09 (104.0) Frame NG and RG NG RG H W D H W D Single-pole Two-pole Three-pole (406.0) 8.5 (10.0) 5.50 (140.0) (406.0) (394.0) 9.75 (9.0) Four-pole (406.0) (80.0) 5.50 (140.0) (406.0) 0.00 (508.0) 9.75 (9.0) Approximate Shipping Weight in Lbs (kg) Frame EG, JG and LG EG JG LG NG RG Single-pole 0.85 (0.39) Two-pole 1.57 (0.71) 11.3 (5.13) Three-pole.8 (1.04) 5.06 (.30) T/M 1.36 (5.61) T/M 46.8 (1.3) (47.0) 5.31 (.41) ETU (5.9) ETU Four-pole.85 (1.9) 6.76 (3.07) T/M 7.1 (3.3) ETU 16.7 (7.39) T/M 16.9 (7.68) ETU 6.0 (8.3) (54.0) V4-T-14 Volume 4 Circuit Protection CA E January 013
7 . EG-Frame (15 15 Amperes) EG-Frame (15 15 Amperes) Product Description EG breaker is HACR rated. Contents Description Page EG-Frame (15 15 Amperes) Number Selection V4-T-16 Product Selection V4-T-17 Accessories V4-T-6 Technical Data and Specifications V4-T-7 Dimensions and Weights V4-T-7 JG-Frame (63 50 Amperes) V4-T-9 LG-Frame ( Amperes) V4-T-45 NG-Frame ( Amperes) V4-T-61 RG-Frame ( Amperes) V4-T-70 Motor Circuit Protectors (MCP) V4-T-80 Motor Protector Circuit Breakers (MPCB) V4-T ma Ground Fault (Earth Leakage) Module..... V4-T-87 Current Limiting Circuit Breaker Module V4-T-91 High Instantaneous Circuit Breaker for Selective Coordination V4-T-96 Special Features and Accessories V4-T-99 Motor Operators V4-T-106 Plug-In Blocks V4-T-108 Drawout Cassette V4-T-109 Handle Mechanisms V4-T-110 Volume 4 Circuit Protection CA E January V4-T-15
8 . Number Selection EG-Frame (15 15 Amperes) E Frame Standard/Application G = IEC/CE/UL/CSA Performance 600Y/ B E S H C K Molded case switch 1 Cannot be UL rated. Available only as 15 and 160A sizes. Number of Poles 1 = One = Two 3 = Three 4 = Four neutral 0% protected 7 = Four neutral 100% protected E G H FF G Amperes Terminations/Hardware Terminals Mounting Hardware M = Metric end caps E = Imperial end caps G = Line/load standard B = Bolt-on Metric Imperial Metric Trip Unit FF = Fixed fixed AF = Adjustable thermal fixed magnetic KS = Molded case switch V4-T-16 Volume 4 Circuit Protection CA E January 013
9 . EG Bolt-On Complete Breaker (Includes Frame, Trip Unit and Mounting Hardware) EG-Frame EG-Frame EG-Frame 18 kaic at 480 Vac Single-Pole Two-Pole Three-Pole Maximum Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Continuous Amps at 40 C Number 1 Number Number 3 15 EGB1015FFB EGB015FFB EGB3015FFB 0 EGB100FFB EGB00FFB EGB300FFB 5 EGB105FFB EGB05FFB EGB305FFB 30 EGB1030FFB EGB030FFB EGB3030FFB 35 EGB1035FFB EGB035FFB EGB3035FFB 40 EGB1040FFB EGB040FFB EGB3040FFB 45 EGB1045FFB EGB045FFB EGB3045FFB 50 EGB1050FFB EGB050FFB EGB3050FFB 60 EGB1060FFB EGB060FFB EGB3060FFB 70 EGB1070FFB EGB070FFB EGB3070FFB 80 EGB1080FFB EGB080FFB EGB3080FFB 90 EGB1090FFB EGB090FFB EGB3090FFB 100 EGB1100FFB EGB100FFB EGB3100FFB 110 EGB1110FFB EGB110FFB EGB3110FFB 15 EGB115FFB EGB15FFB EGB315FFB EG-Frame 35 kaic at 480 Vac Single-Pole Two-Pole Three-Pole Maximum Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Fixed Thermal, Fixed Magnetic Continuous Amps at 40 C Number 1 Number Number 3 15 EGS1015FFB EGS015FFB EGS3015FFB 0 EGS100FFB EGS00FFB EGS300FFB 5 EGS105FFB EGS05FFB EGS305FFB 30 EGS1030FFB EGS030FFB EGS3030FFB 35 EGS1035FFB EGS035FFB EGS3035FFB 40 EGS1040FFB EGS040FFB EGS3040FFB 45 EGS1045FFB EGS045FFB EGS3045FFB 50 EGS1050FFB EGS050FFB EGS3050FFB 60 EGS1060FFB EGS060FFB EGS3060FFB 70 EGS1070FFB EGS070FFB EGS3070FFB 80 EGS1080FFB EGS080FFB EGS3080FFB 90 EGS1090FFB EGS090FFB EGS3090FFB 100 EGS1100FFB EGS100FFB EGS3100FFB 110 EGS1110FFB EGS110FFB EGS3110FFB 15 EGS115FFB EGS15FFB EGS315FFB 1 For bulk pack 4, add suffix BP4 and order quantities of 4. For bulk pack 1, add suffix BP1 and order quantities of 1. 3 For bulk pack 8, add suffix BP8 and order quantities of 8. V4-T- Volume 4 Circuit Protection CA E January 013
Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)
9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationVL circuit breakers. Information guide. www.usa.siemens.com/circuitbreakers
VL circuit breakers Information guide www.usa.siemens.com/circuitbreakers Table of contents Technical data 2 8 DG 150A frame 9 14 FG 250A frame 15 20 JG 400A frame 21 26 LG 600A frame 27 32 MG 800A frame
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationGeneral information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
More informationMolded case circuit breakers
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationSystem pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationMiniature Circuit Breakers and Supplementary Protectors
Miniature Circuit Breakers and Supplementary Protectors Miniature Circuit Breakers and Supplementary Protectors. Industrial Circuit Breakers QUICKLAG............................................. QUICKLAG
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationThe complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
More informationBreaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationProduct Guide. Cable-in / cable-out miniature circuit breakers and supplementary protectors
Product Guide Cable-in / cable-out miniature circuit breakers and supplementary protectors Cable-in / cable-out miniature circuit breakers and supplementary protectors Eaton offers a complete line of
More informationIndex. 17 - Molded case circuit breakers. Molded case circuit breakers. Tmax UL489B Photovoltaic circuit breakers...17.67-17.70
Molded case circuit breakers Index Molded case circuit breakers - Molded case circuit breakers Formula...1 -.10 General information Introduction...1 Circuit breakers for power distribution...2 explanation...3
More informationSIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.
The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved
More informationCircuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services
Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More informationSolid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48
Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 0, RS 8 Zero switching AC Solid State Relay Direct copper bonding (DCB) technology in 25A and 0A types LED indication Clip-on IP 20 protection
More informationPrimary and Secondary Electrical Distribution Systems
Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationReverse-feed applications for circuit breakers
Technical Publication PU01200001E Contents Description Page Intoduction.......................................................................... 2 breaker classifications..........................................................
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationAlternate Methods to Short Circuit Breaker Coordination
Alternate Methods to Short Circuit Breaker Coordination Nguyen Perez, PE Senior Electrical Engineer 2600 Douglas Road, Suite 301 Coral Gables, Florida 305.529.1515 (p) www.brplusa.com Importance in Healthcare
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationProtection Equipment
Protection Equipment Price groups 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 4N1 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors/ circuit breakers up to
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationFuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationMining service breakers with true rms sensing designed specifically for trailing cable applications
Eaton mining service circuit breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications E 2 mining service
More informationBreakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM
Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationFundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers
Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Catalog 2004 Class 601 CONTENTS Description..............................................Page INTRODUCTION.............................................
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationEmergency lighting units EM powerled
M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year
More informationMEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationTmax. Molded case circuit breakers. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com. Tmax.
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationEATON I.L. 29C615E. 4.3 Short Delay/lnstantaneous Trip... 7 4.4 Ground Fault Protection... 7 5.0 Protection Settings... 7
IL 29C615E Instructions for the Digitrip RMS 310 3-Pole and 4-Pole Trip Unit Installation and Operation with L-Frame and MDL-Frame Series C Circuit Breakers Table of Contents Description Page 1 O General
More informationResidual Current Protective Devices
Residual Current Protective Devices /2 Introduction / 5SM3 RCCBs /9 SIQUENCE, 5SM3 and 5SU1 universal -sensitive RCCBs, type B and type B+ /12 Additional components /1 5SM2 RC units /18 5SU1 RCBOs /25
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationCIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit
More informationApplication Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
More informationCUSTOMER CLASS FILE. ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000
Seite 1 von 6 Certification Record CUSTOMER CLASS FILE ABB STOTZ-KONTAKT GmbH 3215-30 098793_0_000 Eppelheimer Strasse 82, SUPPLEMENTARY PROTECTORS- COMPONENT ACCEPTANCE PROGRAM Heidelberg Baden-Wurttemberg
More informationMining service breakers with true rms sensing designed specifically for trailing cable applications
Eaton Mining Service Circuit Breakers E 2 Series 15 2000 Amperes 600 and 1000 Vac Mining service breakers with true rms sensing designed specifically for trailing cable applications E 2 mining service
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationIntersection Preassembled 19-inch Rack
Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
More informationPREFACE. The products covered by this Guide are:
PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More information