1 Qualified Partner Programme QPP R&M RJ45 Connectors Felice Guarna

2 R&M Technology: from PCB to leadframe R&Mfreenet Direct connection module R&M plug and jack Printed circuit board Easy lock RJ45 jack (OEM) R&M RJ45 Connectors / Page 2

3 R&M RJ45 evolution, PCB module (1st generation) R&M RJ45 Connectors / Page 3

4 R&M RJ45 evolution, PCB module (1st generation) NEXT ACS PCB module: [db] Frequency [MHz] R&M RJ45 Connectors / Page 4

5 R&M RJ45 evolution: DCM (2nd generation) Plug Jack R&M RJ45 Connectors / Page 5

6 R&M RJ45 evolution: DCM (2nd generation) NEXT DCM shielded: [db] Frequency [MHz] R&M RJ45 Connectors / Page 6

7 R&M RJ45 evolution: Cat. 6 (3rd generation) Plug Jack a.) b.) R&M RJ45 Connectors / Page 7

8 R&M RJ45 evolution: Cat. 6 (3rd generation) NEXT of Pairs 3,6-5, db Cat. 5 TOC 40 Cat. 6 R&M Cat. 6 MHz R&M RJ45 Connectors / Page 8

9 Driving forces behind evolutions Technical Need to short signal travelling Increase compensation as result of increased frequency Change of plug NEXT values and method of measures Redesign plug to achieve a semiautomated patch cord process Improve contact geometry Achieve interoperability and backward compatibility Economics Eliminate un-necessary costs by eliminating parts Reduce workmanship Keep all parts and processes within the company R&M RJ45 Connectors / Page 9

10 Driving forces behind evolutions Quality Reduce opportunity for errors: manufacturing and terminating Produce with automated process both jack and plug, a further step into patch cord automation Keep performance steady and high both in production and in assembly by designing simple terminations (jack and plug without pair splitting and crossovering) Eliminate all parts creating variance (PCB and manual soldering) R&M RJ45 Connectors / Page 10

11 R&M RJ45 connectors RJ45 theory R&M positioning for jack and plug Classicsystem, Cat. 5e jack Starsystem, Cat. 6 jack and plug R&M RJ45 Connectors / Page 11

12 RJ45 theory, connector system RJ 45 according to IEC X Jack (fixed connector) Plug (free connector) R&M RJ45 Connectors / Page 12

13 RJ45 theory, pin assignment of pair 2 (3, 6) Connector system Patch cord RJ Plug RJ Jack Installation cable 1 1,2 1, ,6 3, ,4 5, ,8 7,8 8 R&M RJ45 Connectors / Page 13

14 RJ45 theory, crosstalk in a connector system Inductive coupling Coupling surface 6 Capacitive Coupling Paar 2 C3 Ck = C1 + C4 - C2 - C C1 C2 C4 Paar 3 R&M RJ45 Connectors / Page 14

15 RJ45 theory, worst case pair combination 3,6-5, Pair 1 Pair 2 R&M RJ45 Connectors / Page 15

16 RJ45 theory, transmission property RJ45 NEXT in an uncompensated plug - jack combination: Cat. 5 limit 50 in db Frequenz [MHz] R&M RJ45 Connectors / Page 16

17 RJ45 theory, how does a compensation work? Balanced transmission: Pair 2 a b + Pair Crosstalk Compensation NEXT jack NEXT plug Compensation = 0 1 wavelength R&M RJ45 Connectors / Page 17

18 RJ45 theory, function zones in a connector system Plug : Jack: Connection technique: Compensation: For example: Printed circuit board IDC block R&M RJ45 Connectors / Page 18

19 RJ45 theory, key factors in compensation X S X B X K L S L B L K The main characteristics of a zone are the following: Size of compensation: X S, X B, X K phase position ( + / - ) Length of contact span: L S, L B, L K [mm] Velocity of propagation: z R&M RJ45 Connectors / Page 19

20 RJ45 theory, effect of the distributed components = = = Distributing the crosstalk over the length of the tracks and the place of origin. R&M RJ45 Connectors / Page 20

21 RJ45 theory, effect of phase shift Signal: Low frequencies High frequencies A B C Result Phase shift of the signal as a result of propagation time along the contacts. R&M RJ45 Connectors / Page 21

22 RJ45 theory, limits of compensation Amplitude variations: NEXT jack Module = db Compensation Kompensation NEXT plug 0 Compensation = db db Stecker Plug -34 db Stecker Plug -36 db Stecker Plug -38 db Stecker Plug MHz Compensated signal 20 db / decade slope R&M RJ45 Connectors / Page 22

23 RJ45 theory, limits of compensation Phase shift due to connector length: Module = -37 db Compensation Kompensation Compensation NEXT jack -20 NEXT plug db mm Modul 45 mm Modul 30 mm Modul 15 mm Modul -80 Compensated signal -100 MHz 40 db / decade rise R&M RJ45 Connectors / Page 23

24 RJ45 theory, simulation of a Cat. 5 print module Plug Connector Jack Compensation Length [mm] = Total X-Talk [db] = NVP = MHz Frequency [MHz] = 100 NEXT [db] = Phase Shift [ ] = Result R&M RJ45 Connectors / Page 24

25 RJ45 theory, example print module Simulation PCB Printmodul Modul db Simulation Effect Einfluss of Länge length Effect Einfl. Amplitude of amplit. Test Messung result -100 MHz R&M RJ45 Connectors / Page 25

26 De-embedded NEXT testing of the plug (1) 1) Measuring reference plug terminated on protruding pairs 2) Cutting off protruding ends 3) Measuring reference jack with reference plug 4) Calculating influence of reference jack jack = total - plug Total Total Reference plug Reference plug Reference jack R&M RJ45 Connectors / Page 26

27 De-embedded NEXT testing of the plug (2) 5) Measuring test object (plug) with reference jack 6) Calculating test object (plug) plug = total - jack Reference jack Total with test object Test object Total with test object R&M RJ45 Connectors / Page 27

28 Interoperability between vendors Manufacturer 1 Manufacturer 2 Manufacturer 3 Module 1 Plug 1 Module 2 Plug 2 Module 3 Plug 3 Cat. 6 Cat. 6 Cat. 6 Mix and Match Module 3 Plug 2 Cat. 6 R&M RJ45 Connectors / Page 28

29 Backwards compatibility Cat. 5e module Cat. 5 plug Cat. 5e module Cat. 6 plug Cat 5e Cat 5e Cat. 6 module Cat. 5 plug Cat. 6 module Cat. 6 plug Cat. 5e Cat. 6 R&M RJ45 Connectors / Page 29

30 Standardisation Cat. 6 - basics 60 Plug Verhalten Module Stecker Behaviour MHz Module NEXT Cat. 5 Cat. 5e Cat Stecke Plug NEXT R&M RJ45 Connectors / Page 30

31 How do we characterise R&M jacks Innovations: Unique shielding contact (patented) Absolutely tool-less Internal mechanically designed compensation Backward compatibility and full interoperability Special contact shape (Cat. 6 only) Front End Back end Technology Innovative manufacturing process assuring: cost effectiveness less parts consistent electrical performance QUALITY Know How R&M RJ45 Connectors / Page 31

32 R&M jacks (EMC) features 360 degree EMC protection Earthing bridge allows free choice of ground bonding topology Bonding by large-area (reed contact world-wide patent) Ensures the required contact pressure for an outstanding EMC performance (high frequency also) Ensures quick and reliable ground bonding Ensures clean cable tension relief Comparative tests show the superiority of shield reed contacting over conventional "clip-on" contacting PLUS SUPERIOR PERFORMANCE R&M RJ45 Connectors / Page 32

33 R&M jacks features Tool-free "Easy Lock" connection technique (IDC) Wiring label for error-free termination (both 568 A and B type) Conductors wired without pair crossover SUPERIOR PERFORMANCE Flexibility Ri-terminatable Used in any places (panel, outlet, MUTO, CP) Can accept larger conductors using special easylock Can be used in different applications: IBM GFP, keystone and special adapters Cat. 5 and Cat. 6 modules are mechanically interchangeable Limited dimension/easy interface allow usage in wide range of existing outlets R&M RJ45 Connectors / Page 33

34 R&M jacks advantages Easy Lock and patented screen contact makes R&M jack the quickest screened Rj45 jack to terminate. Absolutely no tools is required and a maximum reliability is guaranteed. The parallel pair wiring ensures optimum twisting up to the connecting point, this is reflected in the excellent transmission values. Thanks to its minimum installation depth, the module can be easily installed in the largest range of outlets or patch panels world-wide. The R&M patented shielding contact assure fool proofs bonding and reliable screening THE QUICKEST AND SAFEST SHIELD TERMINATION R&M RJ45 Connectors / Page 34

35 R&M jacks compliances Conform to Cat. 5e requirements for connection components according to ISO/IEC and EN Conform to EMC requirements according to EN 55022/class B (interference radiation) UL and CSA certified Data cables with AWG conductor diameter Comply with reliability testing according to ISO/IEC and EN R&M RJ45 Connectors / Page 35

36 R&M jack, mechanical characteristics (measured at 20 C) Number of RJ45 jacks 1 Contact material CuSn Contact surface 0.7 µm gold on 2 µm nickel Insulation material polyester, fiber glass reinforced (UL-94-VO) Mating cycles, min 1000 ISO/IEC Number of IDC terminals, 8 per element IDC contact material, CuSn, tin-plated, 2-4 µm Insulation material polyester, fiber glass reinforced (UL-94-VO) Wire diameter, 0.5 mm (AWG 24) to 0.65 mm (AWG 22) Insulation diameter, 0.8 to 1.6 mm Mating cycles, min 100 Wire strain relief, Through plastic ribs Cable strain relief, Through cables ties Shield contacting 1, Large-surface contact springs (on plug) Shield contacting 2, Shield lance (on cable) Earthing, 2 Earthing terminals 4,8 x 05 mm Shield material, CuSn, tin-plated, 2-4 µm R&M RJ45 Connectors / Page 36

37 R&M jack, electrical characteristics (measured at 20 C) Electrical data Contact resistance Contact resistance Insulation resistance Dielectric strength Dielectric strength < 50 m Ohm (conductor-conductor) < 20 m Ohm (shield-shield) > 500 M Ohm (500VDC) 1000 V, 50 Hz/1 min (conductor-conduct) 500 V, 50 Hz/1 min (conductor-shield) R&M RJ45 Connectors / Page 37

38 CLASSICsystem, Cat. 5e jack The RJ45 jack complies with the requirements of Class De, E (125/250 MHz) The jack complies with the requirements of Cat. 5e (125MHz) It is the only RJ45 module to have been certified in a channel for 250 MHz and 750 MHz by an independent test laboratory (3P). The best module worldwide for Ethernet applications in its category R&M RJ45 Connectors / Page 38

39 STARsystem, Cat. 6 jack Characteristics True Cat. 6 performance (Independent certified by 3P) Backward compatible to Cat. 5e Traceability through integrated serial number Integrated coding scheme Each module tested for NEXT R&M RJ45 Connectors / Page 39

40 STARsystem Cat. 6 jack, the new product R&M RJ45 Connectors / Page 40

41 STARsystem Cat. 6 jack, Cat. 6 the product inside Special spring bronze with Ni plating for enhanced performance and durability Contacts in one piece Gold plating in the contact area Sn plating in the IDC area Patent pending contact design Flexible contacts to fit even RJ11 Contact design to minimise the distance between plug and compensation Compensation in very small size with trimming capability Capacitive and inductive coupling R&M RJ45 Connectors / Page 41

42 STARsystem Cat. 6 jack, Cat. 6 features Meets the requirements for Cat. 6 connecting hardware standard according to latest draft release (Industry agreed) Easy and tool-less termination of all cable types (solid/stranded) Pairs stay together up to termination point Fits in all R&Mfreenet racks and outlets produced so far Special colour to differentiate from Cat. 5e Consistent electrical performance achieved through a fully automated assembly line R&M RJ45 Connectors / Page 42

43 STARsystem Cat. 6 jack, mechanical characteristic Mechanical: Nominal conductor diameter: solid; AWG stranded Nominal insulation diameter: mm Number of conductors: 1-8 Holding of conductors: IDC block (patent EP B1) Colouring scheme: type A or B possible (type A preferred) Screen Contact: tongue (patent EP671787) Screen: 360 degree shielding Conductor termination cycles: 20 Plug interface cycles: > 750 R&M RJ45 Connectors / Page 43

44 STARsystem Cat. 6, jack insertion loss Dämpfung db ,4 3,6 1,2 7,8 Limite MHz R&M RJ45 Connectors / Page 44

45 STARsystem Cat. 6 jack, return loss Return Loss db MHz 5,4 3,6 1,2 7,8 Limit R&M RJ45 Connectors / Page 45

46 STARsystem Cat. 6 jack, NEXT NEXT with a Cat. 6 plug and a Cat. 6 jack [db] ,6-5,4 1,2-5,4 5,4-7,8 1,2-3,6 3,6-7,8 1,2-7,8 Cat Frequency [MHz] R&M RJ45 Connectors / Page 46

47 Cat. 6 and Cat. 5 jack, next comparison NEXT of pairs 3,6-5,4 db MHz Cat. 5 TOC 40 Cat. 6 R&M Cat. 6 R&M RJ45 Connectors / Page 47

48 STARsystem Cat. 6 jack, Cat. 5e backward compatibility NEXT with a Cat. 5/5e plug and a Cat. 6 jack (Backward compatibility) db ,6-5,4 1,2-5,4 5,4-7,8 1,2-3,6 3,6-7,8 1,2-7,8 Cat. 5e Frequency [MHz] R&M RJ45 Connectors / Page 48

49 Cat. 6 hardware: differences from Cat. 5 Cat. 6 module difference: Test method is described in IEC The connecting hardware is measured with the plug (mated) Specific test plug are needed Advantages: Interoperability between products (plug) Full compatible to standard Backward compatibility is guaranteed R&M RJ45 Connectors / Page 49

50 Cat. 6 hardware: peculiarities Interoperability: A Cat. 6 module mated with different (vendors) Cat. 6 plugs, as defined by the standard, must produce NEXT and FEXT values above the limits for Cat. 6 Backwards compatibility: A Cat. 6 module mated with Cat. 5 plugs, as defined by the standard, must produce NEXT and FEXT values above the limits for Cat. 5e De-embedded NEXT of a plug The de-embedded NEXT procedure is a method to determine the crosstalk which is produced inside a plug only. The standard defines ranges of allowed crosstalk for each pair combination and category R&M RJ45 Connectors / Page 50

51 Cat. 6: reference standards EN second edition: (draft) Chapter 8 connecting hardware requirement mechanical and electrical according to IEC ISO/IEC second Edition: (draft) Chapter x connecting hardware requirement mechanical and electrical according to IEC and 7-5 EIA/TIA 568B R&M RJ45 Connectors / Page 51

52 Cat. 6 theory, connector standard IEC /5: Unshielded 8-way connectors for frequencies up to 250 MHz Including: Technical information: inter changeability, backward compatibility, interoperability... Common features: view contacts... Terminations Characteristics: climatic category, electrical, mechanical Test schedule Annexes: test set up s R&M RJ45 Connectors / Page 52

53 Positioning plug, flexibility Thanks to special terminal based on IDC technique, the R&M plug is one of the few available on the market allowing crimping on both solid and stranded wires with increased contact reliability The R&M plug is suitable for semi-automated patch cord production The R&M plug is only crimped in factory R&M RJ45 Connectors / Page 53

54 STARsystem Cat. 6 plug IDC contacts to connect stranded and solid wires Improved reliability compared to piercing contacts (contact resistance) Stranded: mm2 Solid: < 0.5 mm Contact zone always at the same level Parallel mounting of the wire pairs on two layers Crossing 3/6-4/5 is done in front by contacts (patent pending) Well defined crosstalk Superior process control R&M RJ45 Connectors / Page 54

55 STARsystem Cat. 6 plug R&M type Housing of tin plated brass Standard outer dimensions New strain relieve Cables are fixed 360 degree Pairs stay at the same place Better performance For screened cables additionally Screen contact 360 degree Lifetime screen contact Common type Plug outer dimension R&M RJ45 Connectors / Page 55

56 STARsystem Cat. 6 jack an plug, summary The first connecting hardware which meets the relevant Cat. 6 hardware requirement Independent lab certified: 3P First Cat. 6 module without PCB As easy as Cat. 5 to terminate Same connecting hardware at distributor and outlet side Next tested in production R&M RJ45 Connectors / Page 56

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling

More information

Accelerating Light. Copper Cabling Solutions. Category 6A

Accelerating Light. Copper Cabling Solutions. Category 6A Accelerating Light Copper Cabling Solutions Category 6A Category 6A Copper Cabling Solutions Fibernet designs and manufactures premium, high performance copper communication infrastructure and connectivity

More information

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair Presentation; Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair 5 th April 2010 Paul Mathews MInstSMM, CCNA, MIEEE Global Channel Manager Media Types Physical Layer Cabling;

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER Questions to Ask When Planning the Cabling Plant Planning a copper cabling plant to support 10Gbps transmission

More information

Ethernet Cat 5e & Cat 6 Patch Panels

Ethernet Cat 5e & Cat 6 Patch Panels Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.

Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4. Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s

More information

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug Simpler all over. Simpler all round. No special tools required for field ASSEMBLY Cat.6 A 10 GB ether. 500 MHz fully shielded Poe+ Data Voice MFP8 Cat.6 A Field assembly RJ45 plug Less fuss. More flexibility.

More information

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems) Introduction The purpose of this document is to: 1) provide background information beneficial to specifiers

More information

HSD High Speed Data interconnection

HSD High Speed Data interconnection HSD High Speed Data interconnection Fast, safe and robust Very high data bit rate up to 5 Gbit/s SSR smart strain relief enables unstressed solder joints Excellent resistance against cross-talk and RF-EMC

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes

Jack to Jack adapters Plug to Plug U-Link connectors PCB Right angle plastic PCB Right angle - metal. Ordering Codes BNC 75Ω RF CONNECTORS BNC 75Ω RF CONNECTORS To meet the need for higher performance, impedance matched cable interconnections, Amphenol offers a full line of 75 ohm BNC connectors. These connectors can

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care? White Paper Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? Cat. 6A vs. Cat. 6 A What s the Difference and Why Should I Care? TABLE OF CONTENTS 1. Introduction...3 2. Component Standards

More information

Network Design. Yiannos Mylonas

Network Design. Yiannos Mylonas Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which

More information

Copper Patch Cords. Impact On Network Performance and Reliability

Copper Patch Cords. Impact On Network Performance and Reliability Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on

More information

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved

More information

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation RTEX Cable 2015/10/1 Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation Cable and Connector Page 2 2015/10/1 Rev. 5 Motor Business Unit, AIS Company The Kind of Ethernet

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

Universal MATE-N-LOK Connectors

Universal MATE-N-LOK Connectors Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations

More information

Category 6 UTP - Cabling System

Category 6 UTP - Cabling System AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP

More information

Standards Affecting a Premise T-1 Installation

Standards Affecting a Premise T-1 Installation Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION

DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit

More information

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION ipass TM / ipass+ TM 0.8 mm PITCH I/O CONNECTOR SYSTEM EXTERNAL ipass / ipass+ of TABLE OF CONTENTS.0 SCOPE... 3.0 PRODUCT DESCRIPTION... 3. PRODUCT NAME AND SERIES NUMBER(S)... 3. DIMENSION, MATERIALS,

More information

Cat. 6 A EL Incredibly fast Get more

Cat. 6 A EL Incredibly fast Get more Cat. 6 A EL Incredibly fast Get more Productive Intuitive installation Reliable Dependable connection Flexible Wide range of applications Productive. Intuitive installation. Just a few flicks of the wrist

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission

More information

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8 Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications. Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

Ethernet Patch Cord Wiring

Ethernet Patch Cord Wiring Ethernet Patch Cord Wiring C ONTENTS Ethernet Patch Cords & RJ-45 Connectors... 2 Ethernet Patch Cords and UTP Cabling... 3 What s all the twisting about?... 4 Ethernet Applications... 5 568A & 568B Wiring

More information

White Paper. Power over Ethernet Plus Update and Cabling Considerations

White Paper. Power over Ethernet Plus Update and Cabling Considerations White Paper Power over Ethernet Plus Update and Cabling Considerations Power over Ethernet Plus Update and Cabling Considerations TABLE OF CONTENTS 1. Introduction...3 2. Application Objectives...5 3.

More information

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.

More information

INTELLIGENT INFRASTRUCTURE MANAGEMENT

INTELLIGENT INFRASTRUCTURE MANAGEMENT F/ System F/ Assemblies, 9.0 W W W. S I E M O N. C O M SECTION CONTENTS System...............................9. IM Software........................... 9. Analyzers..............................9. System

More information

AMP CO Plus Insert for Cat. 6 A Applications

AMP CO Plus Insert for Cat. 6 A Applications Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus

More information

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions. Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially

More information

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer SYSTIMAX Solutions Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer Issue 2 Draft 1 June 2010 Contents Overview 3 GigaSPEED X10D Guaranteed Channel Performance

More information

CIN::APSE MICROMINIATURE D-SUB

CIN::APSE MICROMINIATURE D-SUB INTRODUCTION CINCH has been producing filter connectors for years and has acquired an in depth knowledge of EMC protection. CINCH offers fast delivery on a wide range of standard filtered connectors and

More information

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors

More information

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges Table of contents Channel, Basic Link and Permanent Link defined....................... 2 Critical Performance Parameters......

More information

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4 This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

.093 [2.36] Commercial Pin and Socket Connectors

.093 [2.36] Commercial Pin and Socket Connectors Product Facts Polarized Cavity identification Low contact-mating force Dual locking lances Detent and positive locking Contacts available in brass and phosphor bronze with tin and gold plating Panel mounting

More information

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov. Slide Number 1

Nathan Dayton ADNET. ADNET SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov. Slide Number 1 Nathan Dayton SYSTEMS, Inc. nathan@muspin.gsfc.nasa.gov Slide Number 1 NETWORK DESIGN Slide Number 2 Previously there have been two phases in the design of a network Department Design Interconnect Design

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up

More information

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially

More information

HARTING. Electronic Connectors

HARTING. Electronic Connectors HARTING Electronic Connectors HARTING Electronic Connectors Global Innovative Technology The HARTING Technology Group has established a reputation for excellence and innovation with decades of experience

More information

Grounding Demystified

Grounding Demystified Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%

More information

Structured Cabling, Earthing & Equipotential Bonding

Structured Cabling, Earthing & Equipotential Bonding White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,

More information

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03 SICK AG WHITEPAPER Cable and connector for HIPERFACE DSL motor drive applications Information for cable manufacturers Note-2_03 Juergen Funkhaenel Application Engineer at SICK STEGMANN GmbH Donaueschingen

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Appendix A lists known cable and connector vendors, part numbers and contact information for sourcing.

Appendix A lists known cable and connector vendors, part numbers and contact information for sourcing. Recommended CAT5/5E (RJ45) Cable Assemblies For Use With Lantronix Device Servers Overview: This application note provides information for making CAT5/5E (RJ45) cable assemblies to facilitate good communications

More information

HARAX circular connector

HARAX circular connector Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor

More information

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

CABLE SPECIFICATION CAN CAB RJ45-SUBD9 CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector

More information

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

ZMR 80 STEREO MODULAR ZONER USERS MANUAL ZMR 80 STEREO MODULAR ZONER USERS MANUAL Lime Technologies http://limetechnologies.co.uk Tel: 08712 233127 ZMR80 Stereo Modular Zoner Mixer Introduction The modular construction of the ZMR80 allows it

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications WHITEPAPER Cable and Connector for Hiperface dsl motor drive applications information for cable manufacturers Version 02 Content Information for cable manufacturers...3 Communication...3 Crosstalk & shielding...3

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

I-PEX MHF4 Micro Coaxial Connector

I-PEX MHF4 Micro Coaxial Connector PRODUCT SPECIFICATION I-PEX MHF4 Micro Coaxial Connector Plug P/N 20448-001R-81 Receptacle P/N 20449-001E RF Connector, RF Cable & Antenna Manufacturer E-mail: sales@wellshow.com.tw Tel: +886-2-24239376

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

with Component Rating A Simple Perspective

with Component Rating A Simple Perspective Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America

More information

Communication, Signal & Data Cables

Communication, Signal & Data Cables Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication

More information

USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION

USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION USB 3.0 INTERNAL CONNECTOR AND CABLE SPECIFICATION Revision 1.0 August 20, 2010 2007-2010 Intel Corporation All rights reserved. Legal Disclaimers THIS SPECIFICATION IS PROVIDED AS IS WITH NO WARRANTIES

More information

The 10G wiring system

The 10G wiring system Edition 03.2010 The 10G wiring system Contents Page ITplus wiring system 2 3 Installation cables 4 5 Distribution equipment 6 7 Connecting technology 8 Connecting boxes 9 10 Patch cables 11 12 Wiring system

More information

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Cable Solutions for Servo and Variable Frequency Drives (VFD) Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect

More information

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope)

SELECTION GUIDE INPUT CHARACTERISTICS. Voltage set point accuracy. Overall voltage error. Temperature coefficient of output voltage (slope) OBSOLETE NMPD0 Series SELECTION GUIDE Order Code Nominal Input Voltage Output Voltage Efficiency (Min.) Power (Max.) V V % W NMPD003C 3. 9.50 NMPD005C 5. 9.5 NMPD0C. 0 0.00 NMPD05C 5. 9 0.00 FEATURES RoHS

More information

Enhanced Category 5 Cabling System Engineering for Performance

Enhanced Category 5 Cabling System Engineering for Performance Engineering for Performance Table of Contents 2 Introduction 2 Where Did It Come From? 2 Enhanced Category 5 Performance What to Test The Link The Channel Don t Forget the Cable Assembly 4 Performance

More information

SMARTen 24 STP Patch Panels

SMARTen 24 STP Patch Panels Features Support 24 ports per 1U High performance, supportable bandwidth up to 500MHz supporting IEEE 802.3an 10Gbps application Conform to ANSI/TIA/EIA-568-B.2-10, ISO/IEC 11801 2.1 edition and CENELEC

More information

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can

More information

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. 1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking

More information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1 BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved

More information

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

EGSTON Standard E2xFxWx 12W

EGSTON Standard E2xFxWx 12W General description The family of switchmode power supplies offers an unmatched degree of flexibility and performance fulfilling even the most stringent requirements. Highly flexible electrical configuration

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd

More information

Panduit 28 AWG Patch Cords Installation Guideline

Panduit 28 AWG Patch Cords Installation Guideline Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure

More information

HP ProCurve High-Speed Transceivers Installation Guide

HP ProCurve High-Speed Transceivers Installation Guide HP ProCurve High-Speed Transceivers Installation Guide Introduction The HP ProCurve High-Speed Transceivers can be installed into a number of HP ProCurve networking devices to provide 100 Mbps and 1000

More information

Network Engineers Everywhere:

Network Engineers Everywhere: Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable

More information

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port This app note applies to the following Lantronix Products: WiPort BG WiPort NR MatchPort BG MatchPort AR XPort Direct+

More information

Managing Connector and Cable Assembly Performance for USB SuperSpeed

Managing Connector and Cable Assembly Performance for USB SuperSpeed Whitepaper Managing Connector and Cable Assembly Performance for USB SuperSpeed Revision 1.0 February 1, 2013 Abstract USB 3.0 connector and cable assembly performance can have a significant impact on

More information

E Series. E Series. Category 6 and 5e. Features

E Series. E Series. Category 6 and 5e. Features E Series Category 6 and 5e CommScope, world leader in copper and fiber connectivity, offers the E Series product line as the ideal solution to all your infrastructure needs for safe and reliable data transmission.

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen A technology primer from NORDX/CDT By, Eric d Allmen Foreword The Telecommunications Industry Association (TIA) and the International Standards Organization (ISO/IEC) are actively engaged in the development

More information