Timber stud Traditional stud partitions and walls with single or twin frames

Size: px
Start display at page:

Download "Timber stud Traditional stud partitions and walls with single or twin frames"

Transcription

1 Traditional stud partitions and walls with single or twin frames 0

2 Traditional stud partitions and walls with single or twin frames db mins The traditional form of plasterboard partition mainly used in residential applications, both in new housing and refurbishment. separating or compartment walls are specified as fire and sound resisting walls in residential units such as flats and apartments to meet the requirements of national Building Regulations. Sector Office / commercial Educational Residential Healthcare Leisure Industrial Timber studs Key facts Can be loadbearing Twin frame and Gypframe RB Resilient Bar constructions to meet sound resisting separating wall requirements Achieves high levels of fire resistance Achieves Part E sound resisting internal partition requirements 0

3 System components Framing s Typically 6, 75 or 89mm depth; 8mm width Gypframe RB Length Resilient Bar 000mm For improved acoustic performance Fixing and finishing products Gyproc Drywall Timber Screws For fixing boards to normal softwoods, super-dried timber and engineered I beams. Gyproc Drywall Screws For fixing boards to Gypframe RB Resilient Bars, and Gypframe RB Resilient Bars to softwood timber framing. Timber battens As required Gyproc Sealant Sealing air paths for optimum sound insulation. Gyproc and Glasroc board products Gyproc WallBoard Thickness.5, 5mm Width 900, 00mm Gyproc SoundBloc Thickness.5, 5mm Width 00mm Gyproc Plank Thickness 9mm Width 600mm Gyproc FireLine Thickness.5, 5mm Width 900, 00mm Glasroc MultiBoard Thickness 6, 0,.5mm Width 00mm Gyproc edge beads Protecting and enhancing board edges. Thistle Board Finish or Thistle Multi-Finish To provide a plaster skim finish. Gyproc jointing materials For seamless jointing. Isowool APR 00 5, 50 and 00mm, for improved acoustic performance. Isowool General Purpose Roll 00mm, for improved acoustic performance. Moisture resistant boards are specified in intermittent wet use areas e.g. shower cubicles. Also available in DUPLEX grades where vapour control is required. 04

4 T F E bgtechnical.enquiries@bpb.com Installation overview Run of partition Timber framing is fixed to the perimeter, abutments, and to frame any openings, using suitable fixings. s are fixed at specified centres. Where Gypframe RB Resilient Bars are required, these are fixed horizontally to the timber studs to one or both sides as specified. Additional framing is installed as required to support heavy fixtures. Boards are screw-fixed to all supports to form the lining. Horizontal board end joints are backed with timber noggings / Gypframe RB Resilient Bars as required. Openings Door openings are formed by fixing full height studs to each side, together with a timber head piece. Door facings are then fixed to the timber ground. Services Services are installed normally after one side is boarded. Timber noggings are fixed to support recessed switch boxes / socket outlets. Table - Gyproc or Glasroc board fixed to timber supports Board type Thickness Width Recommended stud centres mm mm mm Gyproc WallBoard Gyproc FireLine Gyproc Plank Gyproc SoundBloc Glasroc MultiBoard For full installation details, refer to the British Gypsum SiteBook or visit 05

5 Performance ( EN Refer to - Basic principles of system design) Table a 75mm timber stud partitions One layer of board each side of timber studs at 600mm centres. Insulation and board lining as in table. Two layers of board each side of timber studs at 600mm centres. Insulation and board lining as in table. Remedial treatment on one side of existing plasterboard partition (minimum x.5mm plasterboard each side of 75mm x 8mm studs at 600mm centres) using 50mm x 50mm timber battens at 600mm centres, with 50mm Isowool APR 00 between the studs with Gypframe RB Resilient Bar at 600mm centres (fixed horizontally). Insulation and board lining as in table. Detail Board Lining Wall Stud Load ratio Sound insulation R w System type thickness thickness size Without With reference insulation insulation mm mm mm db db New-build 0 minutes fire resistance EN WallBoard x x 8 60% A0600/6 SoundBloc x x 8 60% A0604/7 60 minutes fire resistance EN FireLine x x 8 60% A0608/9 MultiBoard x x 8 60% 8 - G minutes fire resistance EN FireLine x x 8 00% A0600/ MultiBoard x x 8 60% 7 - G06005 Remedial treatment 60 minutes fire resistance EN SoundBloc x x 8 non-loadbearing - 5 A0540 Loadbearing partitions at 60% of the permissible ratio (C4 grade timber maximum). Loadbearing partitions at 00% of the permissible ratio (C4 grade timber maximum). Stud sizes quoted are minimum; larger sizes will enhance performance. 4 5mm Isowool APR 00 insulation NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings and G0 s 06

6 T F E bgtechnical.enquiries@bpb.com BS Table b - 75mm, 89mm and 00mm timber stud partitions One layer of board each side of timber studs at 600mm centres. Insulation and board lining as in table. Two layers of board each side of timber studs at 600mm centres. Insulation and board lining as in table. Remedial treatment on one side of existing plasterboard partition (minimum x.5mm plasterboard each side of 75mm x 8mm studs at 600mm centres) using 50mm x 50mm timber battens at 600mm centres, with 50mm Isowool APR 00 between the studs with Gypframe RB Resilient Bar at 600mm centres (fixed horizontally). Insulation and board lining as in table. Detail Board Lining Wall Stud Load ratio Sound insulation R w System type thickness thickness size Without With reference insulation insulation mm mm mm db db New-build 0 minutes fire resistance BS MultiBoard x x 8 non-loadbearing 4 - G0600 WallBoard x x 8 non-loadbearing 5 6 A0600/005 SoundBloc x x 8 non-loadbearing 8 40 A060/06 SoundBloc x x 8 non-loadbearing 40 4 A0604/07 60 minutes fire resistance BS MultiBoard x x 50 non-loadbearing 4 - G0600 FireLine x x 50 55% 8 - A060 WallBoard x x 8 non-loadbearing 8 4 A0600/007 MultiBoard x x 50 00% 8 - G06004 SoundBloc x x 8 non-loadbearing A0605/08 SoundBloc x x 8 non-loadbearing - 5 A minutes fire resistance BS MultiBoard x x 5 80% 7 - G06005/9 Remedial treatment 0 minutes fire resistance BS FireLine x x 50 55% 4 - A0605 Stud sizes quoted are minimum 5mm Isowool APR 00 insulation 50mm Isowool APR 00 insulation NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings and G0 s 07

7 Performance ( EN Refer to - Basic principles of system design) Table a - 6mm non-loadbearing timber stud partitions One layer of board each side of timber studs at 600mm centres. Lining as in table. One layer of board each side of timber studs at 600mm centres and 5mm Isowool APR 00 in the cavity. Lining as in table. Detail Board Lining Wall Stud Sound insulation R w System type thickness thickness size reference mm mm mm db 0 minutes fire resistance EN WallBoard x x 8 40 A0600 SoundBloc x x 8 40 A06008 SoundBloc x x 8 40 A06009 Stud sizes quoted are minimum. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings and G0 s 08

8 T F E bgtechnical.enquiries@bpb.com BS Table b - 6mm non-loadbearing timber stud partitions One layer of board each side of timber studs at 600mm centres. Lining as in table. One layer of board each side of timber studs at 600mm centres and 5mm Isowool APR 00 in the cavity. Lining as in table. Detail Board Lining Wall Stud Sound insulation R w System type thickness thickness size reference mm mm mm db 0 minutes fire resistance BS WallBoard x x 8 40 A0600 SoundBloc x x 8 40 A06008 SoundBloc x x 8 40 A06009 Stud sizes quoted are minimum. NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings and G0 s 09

9 Performance ( EN Refer to - Basic principles of system design) Table 4a - 75mm and 89mm timber stud compartment / sound resisting walls Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 00mm Isowool APR 00 between the studs on one side. Lining as in table. Two layers of board each side of 75mm x 8mm timber studs at 600mm centres with Gypframe RB Resilient Bars fixed horizontally to one side at 600mm centres. 50mm Isowool APR 00 in the cavity. Lining as in table. Two layers of board each side of 75mm x 8mm timber studs at 600mm centres with Gypframe RB Resilient Bars fixed horizontally to both sides at 600mm centres. 50mm Isowool APR 00 in the cavity. Lining as in table. Detail Board Lining Wall Load ratio Sound insulation R w System type thickness thickness (R w + Ctr) reference mm mm db 60 minutes fire resistance EN SoundBloc x.5 4 Non-loadbearing 56 (48) ) A SoundBloc x.5 57 Non-loadbearing 59 (5) A Plank + FireLine % 6 (5) A0600 Loadbearing partitions at 60% of the permissible ratio (C4 grade timber maximum). NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings and G0 s 0

10 T F E bgtechnical.enquiries@bpb.com BS Table 4b - 75mm and 89mm timber stud compartment / sound resisting walls 4 Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 5mm Isowool APR 00 between the studs on one side. Lining as in table. Two separate timber frames spaced 50mm apart, consisting of 89mm x 8mm timber studs at 600mm centres with noggings. Two layers of board each side. 00mm Isowool General Purpose Roll between the studs on one side. Lining as in table. Two layers of board each side of 75mm x 8mm timber studs at 600mm centres with Gypframe RB Resilient Bars fixed horizontally to one side at 600mm centres. 50mm Isowool APR 00 in the cavity. Lining as in table. Two layers of board each side of 75mm x 8mm timber studs at 600mm centres with Gypframe RB Resilient Bars fixed horizontally to both sides at 600mm centres. 50mm Isowool APR 00 in the cavity. Lining as in table. Detail Board Lining Wall Load ratio Sound insulation R w System type thickness thickness (R w + Ctr) reference mm mm db 60 minutes fire resistance BS 4 SoundBloc x.5 0 minutes fire resistance 4 Non-loadbearing 56 (48) A SoundBloc x.5 57 Non-loadbearing 59 (5) A SoundBloc x % 6 (5) A0600 Plank + FireLine % 6 (5) A minutes fire resistance BS 4 4 SoundBloc x 5 5 Non-loadbearing 58 (5) A Plank + SoundBloc Non-loadbearing 59 (5) A0460 SoundBloc x 5 67 Non-loadbearing 60 (5) A NB The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. NBS work section K0 - Plasterboard drylinings / partitions / ceilings and G0 s

11 Design Planning - key factors The position of services and heavy fixings should be predetermined and their installation planned into the frame erection stage. If a plastered finish is specified, the thickness of the door or glazing frame must allow for the thickness of the plaster finish. To minimise the risk of cracking at the plasterboard joints, seasoned timber with a moisture content not exceeding that recommended in BS 568: Part : 99 should be used. The contractor should ensure that timber supports are accurately spaced, aligned, and levelled. Fixing to super-dried timber It has been established by test that Gyproc Drywall Timber Screws are the best solution for fixing to standard softwood or super-dried timber (approximately % moisture content). Nail popping Loosening of nails in timber can occur through timber shrinkage, or as a result of fixing boards to misaligned or twisted framing. To reduce the risks, boards should be fixed tight to framing members. To minimise any risk of fixing defects occurring, use Gyproc Drywall Timber Screws. Please contact the British Gypsum Drywall Academy Advice Centre for a copy of Technical Information Sheet TI-008 Fixing specification for Gyproc plasterboard to timber framed ceilings and walls. Alternatively visit Cavity fire barriers Cavity barriers may be required to satisfy the requirements of national Building Regulations. Refer to 7 Cavity fire barriers. Services Penetrations Penetrations of fire resistant constructions for services need careful consideration to ensure that the integrity of the element is not impaired and also that the services themselves do not act as the mechanism of fire spread. Refer to.5 Service installations. Electrical Electrical and other small service runs can be routed within the timber stud cavity. The installation of electrical services should be carried out in accordance with the recommendations of the Institution of Electrical Engineers. Switch boxes and socket outlets can be supported from timber stud noggings. Load ratio Loadbearing partitions listed in Tables a, b and 4a, 4b have been tested at the quoted load ratio. Refer to.. Fire protection, structural fire precautions for an explanation of load ratio in the fire limit state. Fixtures Lightweight fixtures can be made directly to the partitions. Medium weight, or heavy fixtures such as cisterns, radiators or wash basins, can be made directly into the timber supports. Additional studs or timber noggings should be installed as appropriate. Board finishing Refer to 0 Finishing systems and decorative effects. Strength and robustness Timber should be aligned and level, and should meet the requirements of BS 568: Part : 99. The dimensions and assembly of timber supports should be sufficient to allow positive fixing of plasterboard without bounce or undue deflection because of the nailing, screwing, or other applied force. When the above fixing conditions cannot be met, a timber batten should be securely fixed to the side of the timber support to increase the bearing surface. Where boards are fixed at maximum centres in adverse conditions, the standard of lining can be affected. Adverse conditions can generally be described as conditions where high humidity occurs, principally in the cold, damp, autumn / winter period. They also refer to buildings under construction over this period, where both the structure and wet applications such as plastering and screeding are subject to slow drying conditions. Partition junctions At a T junction, a ladder frame should be constructed between studs to provide fixing points for the abutting partition, and to support the lining (see Construction details - ). The horizontal members of the frame should be at 600mm maximum centres. Please refer to - Basic principles of system design for general guidance.

12 T F E bgtechnical.enquiries@bpb.com Construction details Head and base T junction Door jamb 4 Corner junction 5 4 Gyproc plasterboard Timber framing Gyproc Sealant Timber ladder frame (ladder members at 600mm max centres) Door frame Skirting Bulk filled with Gyproc jointing materials

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,

More information

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com

FireWall. High performance fireresistant. FireWall. www.british-gypsum.com FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations

More information

British Gypsum Guide to Timber Frame Construction. March 1998

British Gypsum Guide to Timber Frame Construction. March 1998 British Gypsum Guide to Timber Frame Construction March 1998 Timber frame construction has a centuries long tradition in the UK, however, over the last 80 years it has continuously evolved to meet the

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction C09. S0. P0 P Including C09. S0. P0 P08 Sound absorbing solutions introduction C09 Sound absorbing solutions Introduction Sound absorbing solutions This section details sound absorbing solutions which

More information

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com

Guide to domestic building renovation. Telephone: 0844 800 1991 Fax: 0844 561 8816 Email: bgtechnical.enquiries@bpb.com BRITISH GYPSUM A BUSINESS SUPERBRAND SINCE 2008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor:

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge

Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge For Walls 1 Cover: Houghton Estate, luxury residential estate This page: Protea Hotel, Umhlanga Ridge Mass per m 2 CTN BPN Overview Description Gyproc RhinoBoard is manufactured according to the ISO 9001

More information

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb.

Finishing guide. For Thistle plaster and Gyproc plasterboard. Telephone: 08705 456123 Fax: 08705 456356 Email: bgtechnical.enquiries@bpb. BUSINESS SUPERBRAND SINCE 008 Gyproc, Thistle, Gypframe and Glasroc are all registered trade names of BPB United Kingdom Limited. Isover is a registered trade name of Saint-Gobain. Proprietor: BPB United

More information

Glasroc F multiboard Five high performances in one board

Glasroc F multiboard Five high performances in one board Glasroc F multiboard Five high performances in one board Glasroc F multiboard is non-combustible and depending on which of the three thickness you use can give you up to 120 minutes fire resistance. Great

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603 E PL SA M Wet Area Construction Carpentry - Residential Construction Product Code: 5603 Publishing details: Second Edition 2012 TAFE NSW Training and Education Support, Industry Skills Unit Orange and

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

FIRE RATED GLAZING System Guide

FIRE RATED GLAZING System Guide SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST 0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Report Number BTC 17755F

Report Number BTC 17755F Leics. LE NP Tel () 4 Fax () 4 Email btc.testing@saintgobain.com Report Number BTC 77F A FIRE RESISTANCE TEST ON A LOADBEARING TIMBER JOIST FLOOR INCORPORATING 4mm x 7mm x 47mm SOLID JOISTS PROTECTED BY

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength. INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS Multi-Layer Technology provides increased strength. Specifically designed for interior applications. Compatible with most internal

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail

Ecojoist. Practical benefits of Ecojoist. www.eleco.com/gang-nail Ecojoist Practical benefits of Ecojoist. www.eleco.com/gang-nail Gang-Nail Systems, an Eleco plc company, offer integrated solutions f the timber engineering industry which assist in reducing design, production

More information

How To Certify The Scottsdale Construction System

How To Certify The Scottsdale Construction System BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction

More information

Steel-framed Walls. Insulation

Steel-framed Walls. Insulation Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.) Gyproc Plasters The cracks in cement sand plaster are an inherent feature which cannot be completely prevented but can only be controlled and

More information

Post and Beam Construction

Post and Beam Construction Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Clad Direct Glaze Window Installation Instructions

Clad Direct Glaze Window Installation Instructions Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully

More information

CertainTeed. Shaftliner For A rea Separation Firewalls

CertainTeed. Shaftliner For A rea Separation Firewalls CertainTeed Shaftliner For A rea Separation Firewalls M2Tech Shaftliner Type X for Area Separation M2Tech Shaftliner is a specially formulated product for applications where enhanced mold resistance is

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 Riyadh, Saudi Arabia E-mail: riyadhsales@usgme.com Fax: +966 1 4772734 +966 1 4772734 Jeddah, Saudi

More information

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011

GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein

More information

Foundation. Foundation

Foundation. Foundation Moisture Aside from structural concerns, the most important consideration for foundation design is moisture. No client wants a wet basement. No client wants a damp basement. No client wants mold in their

More information

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING IMPORTANT NOTICES AND INFORMATION Read these instructions in their entirety prior to installing windows. Any local building code requirements

More information

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS INFORMATION PAPER IP 21/10 FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS Tom Lennon and Danny Hopkin The use of Structural Insulated Panel (SIP) systems in construction in the UK has increased

More information

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system

More information

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37

Contents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37 Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details

More information

Installation Instructions and Ordering Information

Installation Instructions and Ordering Information The Flush Finish Trimless Door Frame Installation Instructions and Ordering Information CLEAN LINES! The Flush Finish Door Jamb System Manufactured by STUDCO Building Systems Step 1 Verify if you are using

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

TECHNICAL RECOMMENDATION

TECHNICAL RECOMMENDATION TECHNICAL RECOMMENDATION NO: 9 DESIGN OF LIGHT TIMBER FRAMED WALLS AND FLOORS FOR FIRE RESISTANCE Peter Collier Contents Design of Light Timber Framed Walls and Floors for Fire Resistance Relevance Acceptance

More information

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS CONTENTS Introduction 2 Applications 3 Advantages 3 Components 3 6 Design Considerations 7 8 System Features 10 Typical installation Sequence

More information

GreenGuard Housewrap Installation Guide

GreenGuard Housewrap Installation Guide 000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org

Rev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

7. Installation. installation 7.1.1. CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME 7. Installation Window involves the fixing of window frame at an earlier construction stage and subsequent of the window sashes. This is a highly workmanship dependent process. Only trained and approved

More information

Sports Buildings: budget costs for the Flood Relief Fund

Sports Buildings: budget costs for the Flood Relief Fund Sports Buildings: budget costs for the Flood Relief Fund The list below provides typical costs for flood insurance works, typically required by sports clubs or facilities. The list is not exhaustive but

More information

Fire safety in timber buildings

Fire safety in timber buildings Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to

More information

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

NRG 75 CRF NRG GREENBOARD WALL SYSTEM NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark

More information

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS NOISE TECHNICAL FACT SHEET FACT SHEET 5 SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS The sound insulation of exterior walls and roof-ceiling systems refers to their ability to reduce external

More information

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage: Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial

More information

CasoLine QUICK-LOCK grid systems

CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK grid systems CasoLine QUICK-LOCK T grid 90-0mm up to 000-00mm Tile edge details swg CasoLine QUICK-LOCK T/8 000mm CasoLine QUICK-LOCK T/8 600mm A Gyprex / Gyptone CasoLine QUICK-LOCK

More information

Internal wall insulation in existing housing

Internal wall insulation in existing housing Energy Efficiency Best Practice in Housing Internal wall insulation in existing housing A guide for specifiers and contractors Cost-effective External wall appearance maintained Easier to install and maintain

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

Gypsum Board Systems Manual

Gypsum Board Systems Manual CertainTeed Gypsum Board Systems Manual Fire Resistance and Sound Control Design Manual Division 09 GYPSUM BOARD SYSTEMS MANUAL TABLE OF CONTENTS Introduction General Fire Resistance...1 Sound Control...3

More information

Lightweight Partition Design for Residential and Commercial Buildings

Lightweight Partition Design for Residential and Commercial Buildings Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation

More information

Residential Refurbishment. September 2012. ThermoShell Internal Wall Insulation System Design Guide

Residential Refurbishment. September 2012. ThermoShell Internal Wall Insulation System Design Guide Residential Refurbishment September 2012 ThermoShell Internal Wall Insulation System Design Guide The importance of wall insulation in houses Buildings account for 40% of our energy consumption and in

More information

SYSTEM PLATON PLATON MULTI

SYSTEM PLATON PLATON MULTI Isola AS, Platon Factory Lienfossveien 5 N-3678 Notodden Norway Tel: 00 47 35 57 57 00 Fax: 00 47 35 02 75 55 e-mail: isola@isola.no website: www.isola.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Homeowner s Handbook

Homeowner s Handbook Homeowner s Handbook Congratulations on buying your new home This booklet will provide you with important information on the warranty cover for your new home which has been arranged by your developer.

More information

Technical Data Sheet W13. Edition 2005-03. Knauf Fire Walls

Technical Data Sheet W13. Edition 2005-03. Knauf Fire Walls Technical Data Sheet W13 Edition 2005-03 Knauf Fire Walls Knauf Fire Wall A2 - GKF two/ three layer cladding Knauf Fire Wall A1 - Fireboard two layer cladding The structural, statical properties, and characteristic

More information

Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance

Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance Homeowners Handbook Contents Who is Premier Guarantee? Your Structural Warranty What to look out for in your New Home Running in your New Home DIY and Maintenance Structural Warranty Cover This booklet

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

Chapter 2 Basis of design and materials

Chapter 2 Basis of design and materials Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural

More information

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance

More information

Residential Inspection Guidelines

Residential Inspection Guidelines Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

Module 3.7. Thermal bridging

Module 3.7. Thermal bridging Module 3.7 Thermal bridging Learning Outcomes On successful completion of this module learners will be able to - Describe construction details which influence thermal bridging. 2 Introduction to thermal

More information

The FIRE BOOK. Passive fire protection solutions

The FIRE BOOK. Passive fire protection solutions The FIRE BOOK Passive fire protection solutions The importance of providing effective fire protection to buildings cannot be over-emphasised. The consequences of a fire occurring in a building, without

More information

INSTALLATION OF WYKAMOL MEMBRANE PRODUCTS

INSTALLATION OF WYKAMOL MEMBRANE PRODUCTS Wykamol Group Unit 3 Boron Court Network 65 Business Park Hapton Burnley Lancs BB11 5TH Tel: 0845 400 6666 INSTALLATION OF WYKAMOL MEMBRANE PRODUCTS CM8 & KONTRACT 8 1.1 PREPARATION Wykamol wall membrane

More information

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP CONTENTS WHAT IS RISING DAMP STEP 1 SURVEY STEP 2 METER READINGS STEP 3 CONCLUSION STEP 4 PREPARATION FOR TREATMENT STEP 5 TYPE OF TREATMENT STEP 6

More information

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling. i This instruction sheet describes the proper methods for installing Eucatex decorative wall paneling. Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in

More information

Mold Preventing I nterior System

Mold Preventing I nterior System interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal

More information

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market Ian Stewart Passive installer scheme manager September 2011 Introduction to BRE Global Research,

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

Water Resistant Plasterboard

Water Resistant Plasterboard Water Resistant OCTOBER 2012 water resistant plasterboard Water Resistant Wet area application Australian Owned & Manufactured www.bgc.com.au/plasterboard BGC HISTORY & MISSION BGC Fibre Cement and is

More information

IMPACT DAMAGE RESISTANT WALL SYSTEMS

IMPACT DAMAGE RESISTANT WALL SYSTEMS IMPACT DAMAGE RESISTANT WALL SYSTEMS CONTENTS Introduction 2 Advantages 2 2 Material Specifications 2 Design Considerations 3 Framing 5 Plasterboard Installation 5 Health, Safety & Warranty 6 Contact Details

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

- 5 - Table1. Maximum Compartment Volumes

- 5 - Table1. Maximum Compartment Volumes - 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,

More information

Building Control Guidance Note

Building Control Guidance Note Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you

More information

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare? Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.

More information

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM P r o d u c t a p p l i c a t i o n s a n d t e c h n i c a l i n f o r m a t i o n 2 below and above ground V OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM V The flexible, fast and cost-effective answer

More information

Ultimate Acoustic Solutions for Floors & Ceilings

Ultimate Acoustic Solutions for Floors & Ceilings Ultimate Acoustic Solutions for Floors & Ceilings Uniclass L586+L542:N372 EPIC E42+E512:Y45 CI/SfB (43)+(45) R+T (P2) Contains SRS Ltd s Rigorous Standard Details for: Building Regulations Approved Document

More information

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls. Improving the flood resistance of your home Advice sheet 4: Flood-resilient walls. This sheet provides guidance on identifying different types of wall, and reducing the flow of floodwater through them

More information

Code of Standard Practice for Timber Frame Structures

Code of Standard Practice for Timber Frame Structures TFEC 2-2013 Code of Standard Practice for Timber Frame Structures August 2013 Preface This Code is intended to represent a reasonable consensus of what constitutes ordinary and acceptable practice within

More information

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003) NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:

More information