Gauges and Thermometers

Size: px
Start display at page:

Download "Gauges and Thermometers"

Transcription

1 Technical Guide Gauges and Sprinkler Gauges Industrial Gauges Ancillary Equipment

2 Introduction Pressure gauges in this catalogue are activated by a responsive metal element which deforms under the effect of the pressure being measured. The following British and European Standards form the basis of the design and manufacture of the Jet range Series of pressure gauges and of these guidelines. They should also be the source of reference for additional information: BS EN 837- : 998 Jet range has a wide selection of gauges and thermometers, which are used to monitor critical elements that must be controlled in order to achieve desired performance. This guide will allow you to select the most appropriate product to meet a variety of requirements. The Jet range encompasses: Safety The range of the pressure gauge should be selected such that the maximum working pressure does not exceed 75% of the full-scale value when measuring constant pressure, or 65% for fluctuating pressure. The criteria for the selection of a gauge are a function of four factors.. The pressure range (up to 25 bar, or, over 25 bar) 2. The dial size 3. Whether the gauge is Dry or liquid (eg glycerine) filled 4. The state of the material under pressure (as a liquid, or, as gas or steam) Storage Bourdon Tube Dimensions, Metrology, requirement and testing BS EN : mm, 00mm, and 50mm diameters in a variety of pressure settings Pressure gauges should be kept in dry, clean conditions within a temperature range of -40 to +60 C and should be protected from impact damage. Installation 2 Selection and Installation recommendations for pressure gauges. BS EN : 998 Diaphragm and Capsule - Dimensions, Metrology, requirement and testing - 00mm and 50mm diameter bi-metal thermometers - Clip on pipe thermometer - Electronic digital thermometer It is advisable to install the gauge with an isolating cock or valve that facilitates removal of the gauge for maintenance or replacement. On installation a leak tight seal should be achieved. If using sealing materials ensure these do not prevent the fluids entering the gauge. Gauges should be mounted vertically unless designed (and marked) otherwise. Gauges fitted with a blow out device must have at least 20mm clearance from any obstacle to permit the blow out device to operate correctly. Installation should take account of the ambient temperature conditions and should these affect the gauge adversely (eg cause the medium to freeze within the pressure element, then the gauge should be located remotely. A pressure gauge should not be installed in contact with fluids whose temperature is outside -30 to +60 C. Under these conditions a syphon should be installed or a suitably remote location selected, where the temperature conditions are more suitable. 3 The thermometers in this catalogue have circular dials and are actuated by a bimetal strip element, linked to the pointer. The following British and European Standard forms the basis of the design and manufacture of the Jet range series of thermometers and of their guidelines. The standard should also be the source of reference for additional information: Altitude and Sprinkler Gauges - 80mm combined altitude gauge and thermometer - Altitude gauges up to 40 metres - Sprinkler gauges are glycerine filled with two pressure options to choose from Safety The Jet range series of pipeline thermometers are supplied, as standard, with solid brass pockets with a process connection of 2" BSP. The pockets are produced as an interference fit on the brass stem to ensure a high degree of sensitivity. The thermometers should not be installed without these, or other pockets. BS EN 390 : 200 Dial Industrial Gauges Storage Contents page 4 5 Clip on Pipe Thermometer 5 Electronic Digital Thermometer 5 Altitude & Combined Gauges 6 Industrial Gauges 7 8 Order Form 9 Ancillary Equipment - Bourdon Tube for Standard Industrial Applications (Accuracy Class.0) - Bourdon Tube for Standard Industrial Applications (Accuracy Class.6) - Stainless Steel Bourdon Tube for Chemical Applications (Accuracy Class.6) - Pressure gauges - Altitude gauges - Bi-metallic dial thermometers should be kept in dry, clean conditions within a temperature range of -20 to +60 C and should be protected from impact damage. Installation will only measure the temperature experienced by the sensor probe. It is important, to achieve correct readings, that the probe is fully immersed into the flow of the pipeline or vessel. Correct nominal range and stem lengths must be selected before a thermometer is installed. Introduction

3 50mm Diameter Bourdon tube copper alloy 4" BSP bottom or back entry male connection Dual scale bar and psi Accuracy class 2.5 to BS EN 837-:998 00mm and 50mm Diameter Bottom and back entry 50mm or 00mm immersion length c/w BSP 2" pocket Pocket for 00mm dial - push fit Pocket for 50mm dial - screw fit Dual scale ºC and ºF 00mm and 50mm Diameter 00mm and 50mm Diameter Bourdon tube copper alloy Accuracy class to BS EN 390:200 Materials The standard pockets supplied with these thermometers are machined from solid brass and are suitable for pressures up to 25 bar. Alternative materials such as stainless steel can be supplied. Customers uncertain of the suitability of the standard pockets should contact a member of staff. 4 00mm Pressure Gauge 5 Materials Those parts of a pressure gauge which are in contact with the fluid being measured (the wetted parts ) are, as standard, made from alloys of copper (brass and phosphor bronze) but can be stainless steel or other more exotic materials. If doubt exists as to the suitability of the standard gauge, please contact a member of our sales staff. 3 entry male connection Dual scale bar and psi Accuracy class.6 to BS EN 837-:998 00mm 50mm N20700 N2060 N2070 N206 N20702 N2062 N20703 N2063 N20704 N20620 Thermometer 0-20ºC c/w 50mm pocket bottom entry Thermometer 0-20ºC c/w 00mm pocket bottom entry Thermometer 0-20ºC c/w 50mm pocket back entry Thermometer 0-20ºC c/w 00mm pocket back entry Thermometer ºC c/w 50mm pocket bottom entry 00mm 50mm N20706 N20622 N20707 N20623 N2070 N20956 N20957 Thermometer ºC c/w 50mm pocket back entry Thermometer ºC c/w 00mm pocket back entry 50mm Spare brass screwed pocket, 50mm dial 50mm Spare brass push fit pocket, 00mm dial 00mm Spare brass screwed pocket, 50mm dial N20705 N2062 Thermometer ºC c/w 00mm pocket bottom entry N mm Spare brass push fit pocket, 00mm dial for 50mm Diameter for 00/50mm Diameter Note: Push fit gauges can be installed into an existing screw fit pocket Cat. No. 00mm 50mm Clip on Pipe Thermometer Electronic Digital Thermometer N2050 Pressure gauge 0-6 bar & psi bottom entry N20590 Pressure gauge bar & psi 66mm case size Data hold function N205 Pressure gauge 0-6 bar & psi back entry N2059 N20605 Pressure gauge 0-4 bar & psi Comes complete with fixing spring Large digital display 50mm Pressure Gauge N2052 N2053 Pressure gauge 0-6 bar & psi bottom entry Pressure gauge 0-6 bar & psi back entry N20592 N20593 N20594 N20595 N20955 N20606 Pressure gauge 0-6 bar & psi N20603 Pressure gauge 0-0 bar & psi Pressure gauge 0-6 bar & psi Pressure gauge 0-25 bar & psi Back flange for 00mm dia pressure gauge Clip on Pipe Magnetic attachment Resolution 0. C (between -9.9 C and +99 C, otherwise C) 500mm cable with stainless steel probe N2295 N2296 Temperature range 0 to +20ºC -40 to +40ºC Temperature range N ºC to +200ºC Electronic Digital Thermometer

4 Industrial Gauges Industrial Gauges Bourdon type copper alloy Bourdon Tube for Standard Industrial Applications (Accuracy Class.0) Conforms to BS EN 837- Loose red pointer 3 8 " BSP bottom connection Dry or glycerine filled Phosphor bronze/brass wetted parts Glycerine N2005 N2035 Pressure Gauge 0-30 PSI/bar N2006 N2036 Pressure Gauge 0-60 PSI/bar N2007 N2037 Pressure Gauge 0-00 PSI/bar Dual scale metres and feet Accuracy class.6 to BS EN 837-:998 Direct vertical brass mounting 3 8" BSP male connection Glass window N2008 N2038 Pressure Gauge 0-60 PSI/bar N2009 N2039 Pressure Gauge PSI/bar N200 N2040 Pressure Gauge PSI/bar N20 N204 Pressure Gauge PSI/bar Stainless steel bayonet type bezel N202 N2042 Pressure Gauge PSI/bar Bourdon Tube Pressure Gauge N20525 N20526 Altitude Gauge 0-0 mtr & 30Ft Altitude Gauge 0-5 mtr & 50Ft Bourdon Tube for Standard Industrial Applications (Accuracy Class.6) 6 2" BSP bottom connection Scale 0/20ºC & 0/30 metre Altitude Gauge 80mm Combined Thermometer & Altitude Gauge N20527 N20528 Altitude Gauge 0-25 mtr & 80Ft Altitude Gauge 0-40 mtr & 30Ft Conforms to BS EN mm diameter Phosphor bronze/brass wetted parts Direct vertical brass mounting 4" BSP male connection Direct vertical or horizontal brass mouting Plastic window Glycerine N285 N225 Pressure Gauge 0-60 PSI/bar N286 N226 Pressure Gauge 0-00 PSI/bar N287 N227 Pressure Gauge 0-60 PSI/bar N288 N228 Pressure Gauge PSI/bar N289 N229 Pressure Gauge PSI/bar N290 N2220 Pressure Gauge PSI/bar N29 N222 Pressure Gauge PSI/bar N292 N2222 Pressure Gauge PSI/bar N293 N2223 Pressure Gauge PSI/bar Bourdon Tube Pressure Gauge (Glycerine Filled) 7 Sprinkler Gauges Phosphor bronze/brass wetted parts Direct vertical brass mounting 3 8 " female x 2" male BSPT self seal leakproof connector Accuracy class.0 Glass window Stainless steel bayonet type bezel Glycerine filled Altitude Gaues & Sprinkler Gauges Component N mm Combined Thermometer & Altitude Gauge Combined Therm and Altitude Gauge Sprinkler Gauge N2246 Sprinkler pressure gauge 0-0 bar N2247 Sprinkler pressure gauge 0-6 bar Stainless Steel Bourdon Tube for Chemical Applications (Accuracy Class.6) For all process apllications (except direct hygienic) where the medium is damaging to brass/ bronze alloys Conforms to BS EN 837- Stainless steel wetted parts 3 8" or 2" BSP male connection Direct vertical or stainless steel mouting Stainless steel bayonet type bezel Laminated safety glass window For further options see page 3 8 " BSP N2255 N2256 N2257 N2258 N2259 N2260 N226 N2262 N2263 Pressure Gauge 0-5 PSI/bar Pressure Gauge 0-30 PSI/bar Pressure Gauge 0-60 PSI/bar Pressure Gauge 0-00 PSI/bar Pressure Gauge 0-60 PSI/bar Pressure Gauge PSI/bar Pressure Gauge PSI/bar Pressure Gauge PSI/bar Pressure Gauge PSI/bar 2 " BSP N2285 N2286 N2287 N2288 N2289 N2290 N229 N2292 Bourdon Tube Pressure Gauge (Stainless Steel) Pressure Gauge bar Pressure Gauge bar Pressure Gauge 0-4 bar Pressure Gauge 0-6 bar Pressure Gauge 0-0 bar Pressure Gauge 0-6 bar Pressure Gauge 0-25 bar Pressure Gauge 0-40 bar

5 XXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXX Jet Jet range logo gauges give you the customer the opportunity to use your company logo or emblem on your own tailor-made gauge. This service is available on a select range of pressure gauges, thermometers and altitude gauges, adhering to the same standards and quality of the standard Jet range gauges which are all covered by a 2 month guarantee. All Jet range Logo gauges feature black steel cases, acrylic windows and chrome plated bezels. Order Form Logo Gauge 00mm diameter - Vertical 50mm diameter - Vertical 00mm and 50mm diameter N20740 N bar 0-4 bar N20750 N bar 0-6 bar Bourdon Tube copper alloy N20742 N20743 N bar 0-0 bar 0-6 bar N bar 3 entry male connection 8 N bar Dual scale (bar and PSI) Accuracy class to BS EN 837:998 9 WOLSELEY DOCUMENT REFERENCE NO. Logo Gauge Cat. No. N20760 N2076 N20762 N metre 0-5 metre 0-25 metre 0-40 metre Bourdon Tube copper alloy 3 entry male connection Dual scale (metric and imperial) Accuracy class to BS EN 837:998 LOGO NAME: (Caps) TOTAL NO.OF GAUGES: MIN ORDER QTY - 25 UNITS TOTAL IF LESS THAN 25 ARE REQUIRED THERE WILL BE A 25 SET UP CHARGE Please send high resolution image of new logo with Wolseley document reference no. (300dpi) to: jet.gauges@wolseley.co.uk Bi-Metallic Dial Quality bi-metallic movement Bottom or back entry options available 50mm or 00mm immersion lengths Comes with brass pocket 2" BSP x 2mm Dual Scale (ºC and ºF) Accuracy class to BS EN 390: mm diameter - Vertical N20768 N20770 N20772 N ºC and L = 50mm ºC and L = 00mm 0+20ºC and L = 50mm 0+20ºC and L = 00mm 00mm diameter - Horizontal N20776 N20778 N20780 N ºC and L = 50mm ºC and L = 00mm 0+20ºC and L = 50mm 0+20ºC and L = 00mm 50mm diameter - Vertical N ºC and L = 50mm N ºC and L = 00mm N ºC and L = 50mm N ºC and L = 00mm 50mm diameter - Horizontal N ºC and L = 50mm N ºC and L = 00mm N ºC and L = 50mm N ºC and L = 00mm L = Pocket length CUSTOMER NAME: TEL. NUMBER: WOLSELEY CONTACT NAME: BRANCH ADDRESS: TEL. NUMBER: CUSTOMER SIGNATURE: SIGNATURE: FAX: Note: Wolseley staff member to fill in details on front and reverse of form with customer present and fax to: +44 (0)

6 Ancillary Equipment 00mm diameter Order Indicate order quantity in below box. Ancillary Equipment Jet range offers a variety of ancillary equipment to support the gauges and thermometers in the range. Cat. No. Pressure range psi N N N N N N mm diameter Cat. No. Pressure range psi N N N mm diameter 4" 3 8" 2 " N6052 N60522 N60523 Brass F x F Gauge Cock N6900 K69002 N69003 Jet Lever Operated Ball Valve N2090 N20902 N20903 U-Syphon: Mild steel - N U-Syphon: Brass N20908 N20909 N2090 Ring-Syphon: Mild Steel N209 N2092 N2093 Ring Syphon: Brass - N Ring-Syphon: Stainless Steel N20920 N2092 N20922 Brass M/F Snubber (used to eliminate surge and pressure pulsation to pressure gauges) 0 Altitude range Cat. No. (Ft) (M) N N N N Bi-metal 00mm diameter Cat. No. Temperature range Immersion length (mm) Connection type N ºC to +60ºC 50 bottom connection N ºC to +60ºC 00 bottom connection N to +20ºC 50 bottom connection N to +20ºC 00 bottom connection N ºC to +60ºC 50 back connection N ºC to +60ºC 00 back connection N to +20ºC 50 back connection N to +20ºC 00 back connection 50mm diameter Options for Industrial Gauges Industrial Applications (Accuracy Class.0) Options 2" BSP vertical male connection 60mm diameter gauges Back flange for surface mounting Ranges: compound, vacuum and up to 5,000 PSI/bar Industrial Applications (Accuracy Class.6) Options Suitable for Panel Mounting Ranges: Compound, Vacuum and up to 0,000 PSI/Bar Chemical Applications (Accuracy Class.6) Options Back flanges for surface mounting Ranges: compound, vacuum and up to 0,000 PSI/Bar LOOK OUT for other Jet range brochures Cat. No. Temperature range Immersion length (mm) Connection type N ºC to +60ºC 50 bottom connection N ºC to +60ºC 00 bottom connection N to +20ºC 50 bottom connection N to +20ºC 00 bottom connection N ºC to +60ºC 50 back connection N ºC to +60ºC 00 back connection N to +20ºC 50 back connection N to +20ºC 00 back connection

7 Pipe Center is the specialist supplier of commercial heating plant and pipe systems. Branches offer a range of products including boilers, water heaters, radiators, pump and commercial showers. Pipe Center also stock the widest ranges of pipes, fittings and valves in: Carbon steel Copper Brass Pressure plastics Stainless steel Bronze Branch locations For further information about Jet range products, please visit or contact Some products also available from: Whilst every care has been taken to ensure that the information included in this document was accurate at the time of printing, we reserve the right to change specifications at any time. The photographs reproduced in this publication are within the constraints of the printing process and are NOT to be used for matching purposes. E&OE. Catalogue Number: Y98056 ref:4569

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

79 GAUGE / THERMOMETER H N O

79 GAUGE / THERMOMETER H N O 79 GAUGE / TERMMETER plastic-housing 80 A 100 - D 40 Centre back entry and are not aggressive to copper alloys. Design: E 837-1. Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure

More information

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories Commercial / HVAC / Plumbing Specification Guide For Pressure & Temperature Instruments & Related Accessories Prepared for Consultant, Design & Specification Engineers Gauges Contractor Gauge (PCT, PCT-LF)

More information

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

SOLFRUNT Pressure Gauges and Other Products for the Process Industries A1 SOLFRUNT Pressure Gauges and Other Products for the Process Industries AMETEK s line of high quality process gauges are specifically designed to meet the demanding needs of the chemical and petroleum

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications Page 1 of 12 TI-S21-07 CH Issue 1 Cert. No. LRQ 0963008 ISO 9001 2-Port Self-acting Temperature Control Valve Selection How to select a system Valve selection: 1. Is the application for heating or cooling?

More information

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503 1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix

More information

Bimetal thermometer Model 52, industrial series

Bimetal thermometer Model 52, industrial series Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Thermometer in stainless steel with capillary and switch contacts

Thermometer in stainless steel with capillary and switch contacts Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

BB-18 Black Body High Vacuum System Technical Description

BB-18 Black Body High Vacuum System Technical Description BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

ORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

ORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar Chiavari (Ge) - Italia Tel.: Italia + 0185 + 38.50.10 Fax: Italia + 0185 + 38.50.11 e-mail: orlando@orlando.it Http://www.orlando.it M R 50...: Radial pressure gauge ø 50 ( available scale in bar: 4, 6,10,12,16

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Steam System Best Practices Condensate System Piping

Steam System Best Practices Condensate System Piping Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum

More information

API Flanged Safety Relief Valves Series 526 CATALOG

API Flanged Safety Relief Valves Series 526 CATALOG API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL

SIMPLAIR PIPING. www.irtools.com 1-800-376-TOOL SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Technical Information

Technical Information Technical Information This section of the catalogue provides technical information that will help specify, install and maintain Surelock McGill devices and components. The topics are listed below: Blast

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

How To Replace A Reverse Osmosis Water Tank

How To Replace A Reverse Osmosis Water Tank ALL MODELS REVERSE OSMOSIS WITH NONAIRGAP FAUCET 1. Read all instructions carefully before starting installation. 2. Find the cold water line beneath your sink. The cold water is typically on the right.

More information

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement Boilers Compressors Chillers Pipe Systems HVAC & Refrigeration Applications Pressure and Temperature Measurement R Mechanical Pressure Refrigeration Gauge WIKA s type 111.11RF 2½ gauges, which have an

More information

CONTENTS 1. INTRODUCTION...1 2. METHODOLOGY...2 3. RESULTS & FINDINGS...9 APPENDIX

CONTENTS 1. INTRODUCTION...1 2. METHODOLOGY...2 3. RESULTS & FINDINGS...9 APPENDIX Load Testing of Balustrade Systems Test Report No. S365 CONTENTS 1. INTRODUCTION...1 2. METHODOLOGY...2 2.1 BALUSTRADE LOAD ASSESSMENTS... 2 2.2 TEST SYSTEMS... 3 2.3 TEST PROCEDURE... 8 3. RESULTS & FINDINGS...9

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog 9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G Catalog January 07 Contents Commercial Pressure Switches Pressure Switches b Selection..............................................

More information

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description. Worldwide Contacts www.tyco-fire.com Series Multiple Jet Controls DN20, DN25, DN40, and DN50, 2 bar BSPT Inlet & Outlets Threads General Description The TYCO Series Multiple Jet Controls are control valves

More information

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com. Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

Baumann 87000 Flexsleev Sanitary Control Valve

Baumann 87000 Flexsleev Sanitary Control Valve Product Bulletin D103345X012 Baumann 87000 Flexsleev Sanitary Control Valve The Baumann 87000 control valve (figures 1 and 2) is excellent for throttling high purity liquid or gaseous media commonly found

More information

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS THERMOMETERS BIMETA THERMOMETERS (DIN 1 1 - PART 2) TYPE: MBT 7 2 4 8 1 12 C APPICATION This thermometer is designed for indication of oil temperature in both transformers with epansion conservator or

More information

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G EN 215-1 HD 1215-2 Application RA 2910 built-in sensor RA 2920 tamperproof RA 5062 remote sensor temperature adjuster RA-FN

More information

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project: PLATE HEAT EXCHANGER Installation Manual Customer Name: Serial number: Purchase order number: Project: Table of Contents ----------------------------------------------------------------- Page: 2 3 Name

More information

Laddomat 21-60 Charging unit

Laddomat 21-60 Charging unit Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the

More information

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES 01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

Cylinder head gasket, replacement

Cylinder head gasket, replacement "VCC065612 EN 20110604" 1(7) Cylinder head gasket, replacement Special tools: 999 5098 Disconnect battery earth lead Drain coolant Remove heat shield over exhaust manifold. (Only the two bottom bolts on

More information

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

Vacuum. How It Relates to Refrigeration And Air Conditioning Service Vacuum How It Relates to Refrigeration And Air Conditioning Service Moisture In A Refrigeration System Visible Moisture Water Droplets Uncommon, but it can occur Invisible Moisture Water Vapor Found in

More information

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Coolflo Safe Touch Shower Mixing Valve ST20015CP Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

Spare Parts List M96A.24SM/B M96A.28SM/B

Spare Parts List M96A.24SM/B M96A.28SM/B *16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.

More information

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges)

Introduction to vacuum gauges. Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges) Introduction to vacuum gauges Vacuum Gauges where the Pressure Readings are Independent of the Type of Gas (Mechanical Vacuum Gauges) BOURDON Vacuum Gauge The inside of a tube which is bent into a circular

More information

SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / info@superyachtspares.com / +31 183 639193

SUPERYACHT SPARES. Nozzles and portable monitors. www.superyachtspares.com / info@superyachtspares.com / +31 183 639193 Nozzles and portable monitors Rosenbauer - Nozzles and portable monitors EN Maximum extinguishing effect. Minimal water consumption. The Rosenbauer nozzle enables the manual adjustment of the water flow

More information

series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N

series 5350 5351 Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN 12165 CW617N Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM ISO 9 No. CLEFFI / GB replaces / GB Function Pressure reducing valves are devices which, when installed

More information

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2 Instruction Manual Dew Point Tester The CVS Dew Point Tester is a chilled mirror apparatus, which operates by attaining the conditions necessary by the definition of dew point. When a gas is cooled out

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Newloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists

Newloc Acetal. Plastic Push-to-Connect Fittings. Fluid Transfer Specialists Newloc Acetal Plastic Push-to-Connect Fittings Fluid Transfer Specialists Newloc Acetal Extremely easy to install no tools necessary Certified by the National Sanitation Foundation (NSF-1 and NSF-1) Instant

More information

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap 1263050/6 IM-P126-07 ST Issue 6 BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation

More information

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk

Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk 1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Application Integrated valves, type RA-N (013G0372) and RA- U (013G0373), with built-in presetting are designed for incorporation

More information

A99B Series Temperature Sensors

A99B Series Temperature Sensors FANs 125, 121, 930, 930.5 Product/Technical Bulletin A99 Issue Date 0615 A99B Series Temperature s The A99B Series Temperature s are passive PTC (Positive Temperature Coefficient) sensors. The A99B sensors

More information

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application Integrated valves, type RA-N (013G1382) and RA- U (013G1383), with built-in presetting are designed for

More information

Quick response concealed horizontal sidewall sprinkler

Quick response concealed horizontal sidewall sprinkler January 1, 2011 Sprinkler 63a 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK408 is a small solder link and lever spray sprinkler designed for installation on concealed

More information

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18 ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

STABITHERM INSTALLATION & SERVICE BOOKLET

STABITHERM INSTALLATION & SERVICE BOOKLET STABITHERM INSTALLATION & SERVICE BOOKLET TABLE OF CONTENTS Introduction...3 Warranty...3 Product Range and Physical Description...4 Method of Operation...5 Recommended Pressures and Temperatures...6 Flow

More information

Description of functions

Description of functions Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Automatic control equipment for HVAC systems

Automatic control equipment for HVAC systems Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts

More information

Product catalogue, pipe and sewer cleaning systems

Product catalogue, pipe and sewer cleaning systems Product catalogue, pipe and sewer cleaning systems Nozzles Rotorjet trolley Hose reels Cleaning devices www.hammelmann.com Contents (Navigation via Bookmarks) Rotorjet trolley Rotary joints, spray pipes

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Submersion/Insertion Toroidal Sensor

Submersion/Insertion Toroidal Sensor Instruction Sheet PN 51A-228/rev.P December 2010 Model 228 Submersion/Insertion Toroidal Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION SENSOR/PROCESS

More information

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions. B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary

More information

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF) Please read these instructions thoroughly before installation and ensure they are passed

More information

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1 Visage Digital Digital diverter TM Installation guide Visage Digital diverter installation instructions Page 1 Visage Digital diverter Visage Digital concealed with adjustable and fixed head Visage Digital

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications. The

More information

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480

Installation and Service Instructions. Neutralization System Part no. 7441823 Grünbeck part no. 410480 Installation and Service Instructions for use by heating contractors Neutralization System Part no. 7441823 Grünbeck part no. 410480 Safety and Installation Requirements Please ensure that these instructions

More information