Metering Devices IQ 300
|
|
- Kristina Johnson
- 7 years ago
- Views:
Transcription
1 Metering Devices Technical Data Supersedes TD T.E pages 1 8 dated May 2001 Description Page Metering Devices General Description Features, Functions and Benefits Application Description Specifications Field Wiring Connection Diagrams Dimensions Product Selection
2 Technical Data Page 2 Effective: March 2004 Metering Devices General Description The s thin display and flexible mounting capabilities make it perfectly suited for any application where an accurate, multi-function meter is desired, such as panelboard and switchboard mains and feeders, motor control centers, and both low voltage and high voltage metal-enclosed switchgear. One provides an alternative to an assortment of individually wired and mounted ammeters, voltmeters, ammeter and voltmeter switches, wattmeters, varmeters, power factor meters, frequency meters, watthour and demand meters. ANSI C12 Class 10 revenue metering accuracy makes the an ideal choice for circuits where precise energy measurements are required. The can be easily programmed from the faceplate with display and keypad which features a two-line reverse mode LCD display with LED backlight. Auto scrolling function allows hand-free viewing of all voltages and currents. All measurements can be viewed from the local display. The can also be configured and monitored using PowerPort, free software available on the Eaton Electrical Web site, or can be used with PowerNet, the full-featured power management system software (models IQ 320 and IQ 330 only). Features, Functions and Benefits Optional I/O The IQ 330 and IQ 330M models include two digital inputs and two outputs along with a single analog input. The digital inputs can be used to show the status of an external device on the meter display and via communications. Examples include breaker position, motor starter status, protective relay trip or any other device status. The analog input accepts a standard 4 to 20 ma input, is shown on the display from 0 to 100%, and is available through communications. The analog input can be used to read transformer temperature, motor speed or any analog process signal. The two digital outputs can be remotely controlled via communications or can be programmed in either of two different alarm modes. In one mode, the output will activate based upon the measured system voltage and can act as either an over- or undervoltage relay. The second mode will enable the output to alarm on a phase loss condition. Meter Sealing The IQ 330 and IQ 330M models have a hardware seal that prohibits the changing of settings or the resetting of values. Meter Mounting The base module can be display mounted, panel mounted, DIN-rail mounted or side-mounted. The display only requires 1.50 inches (38.1 mm) behind the panel it is mounted in, including display to base cable. Bright display with eight large numeric digits along with a 10- character description of the measured value makes the ideal for switchgear mounting. Base unit can be display mounted for simple, one-hole installation. Base unit can be mounted up to 10 feet (3 m) away from display and has three mounting options. Ratings Application to 200 kv, no PTs to 600 V. CT ratios selectable from 5 to 8,000 A. Three-phase, 3- or 4-wire. Control Power Input All +/- 10%. Model IQ 310: 50/60 Hz Model IQ 320: 50/60 Hz Models IQ 330 and IQ 330M: 50/60 Hz Display Settings Display automatically switches to power saving dim mode after 5 minutes of inactivity. User-selectable settings for: Auto scroll time-out. Contrast. Application Description Monitoring of electrical parameters. Can be used on both low voltage and medium voltage assemblies. Metered/Monitored Parameters Phase currents. Voltage, L-L, L-N. Power: real, reactive, apparent. Energy: watthours, varhours, and VA hours. Frequency. Power factor. Minimum/maximum values. System demand. KYZ energy pulse output. Note: Models IQ 320 and IQ 330 only. ANSI C12.16 revenue metering accuracy (1%). Communications The IQ 320 and IQ 330 models have interface capability to computer network for data collection, storage and/or printout via the Cutler-Hammer PowerNet system. The IQ 330M model has an industry standard RS-485 multi-drop serial interface with the Modbus RTU communication protocol built-in. This interface can be used to connect the IQ 330M to a wide variety of Building Management Systems, Programmable Logic Controllers and other systems utilizing this communication network.
3 Metering Devices Technical Data Effective: March 2004 Page 3 Physical Characteristics Two-line reverse mode LED back-lit LCD display with helpful icons. Standard IQ meter cutout. Display height: inches (260.4 mm). Display width: 6.72 inches (170.7 mm). Display depth (behind panel): 0.75 inches (19.1 mm). Membrane faceplate designed and tested to meet NEMA 12, 3R and IP 52. Base unit can be mounted on the rear of the display. Three separate base mounting options. Listings/Certifications UL and CUL listed under UL 3111 CSA C22.2 # Meets IEC CE mark for applications where European compliance is required. Specifications Compatible with the following systems: Three-phase, 3-wire. Three-phase, 4-wire. Current Input (Each Channel) Nominal full scale current: 5 amperes ac. Current range: two times nominal. Overload withstand: 10 amperes ac continuous 50 amperes ac 1 second Input impedance: 0.01 ohms. Burden: VA. Voltage Input (Each Channel) Voltage range (nominal):. Overload withstand: 660 Vac continuous 800 Vac 1 second Input impedance: 2 megaohms. KYZ Output Models IQ 320, IQ 330/330M: Maximum voltage: 240 Vac/300 Vdc, 125 Vac/175 Vdc. Maximum current: 96 ma 96 ma. Isolation rating: 3750 Vrms 3750 Vrms. Digital Inputs Note: Models IQ 330 and IQ 330M only. Input voltage rating: Vdc. Maximum current rating: 96 ma. Digital Outputs Note: Models IQ 330 and IQ 330M only. Maximum voltage: 125 Vac/175 Vdc. Maximum current: 96 ma. Isolation rating: 3750 Vrms. Analog Input Note: Models IQ 330 and IQ 330M only. Value displayed: 0 100%. Minimum resolution: 1%. Nominal current rating: 4 20 ma, 30 ma. Maximum current input: 30 ma. Maximum voltage input: 6.8 V. Input impedance: 231 ohms. CT (Primary) Settings Select from 256 ratios ranging from 5:5 to 5:8,000. PT (Primary) Settings Select from 256 ratios ranging from 1.0:1 to 1690:1. Table 1. Environmental Conditions Base Operating Temperature Frequency Range 50/60 Hz. Communication Speed INCOM : 1200 or 9600 baud. Note: Models IQ 320 and IQ 330 only. RS-485: 9600 or 19,200 baud Half duplex Note: Model IQ 330M only. Electrical Standards Display C 0 50 C Storage Temperature C C Maximum Relative Humidity 80% up to 31 C decreasing linearly 50% at 50 C. UL, CUL and CSA listed. UL File Number E CE mark for applications where European compliance is required. Safety IEC Incl. Amend. 1 and 2. EN CSA C22.2 Number UL EMC Emissions FCC Part 15 Class A. CISPR 11/EN Group 1 Class A. Immunity. Electrostatic Discharge. EN /EN kv Contact Discharge. 8 kv Air Discharge. Electrical Fast Transient EN /EN kv power lines. 2 kv signal lines. Radiated Immunity EN /EN V/m. Conducted Immunity EN /EN V/m. Power Frequency Magnetic Field EN A/m. Table 2. Metered Values (Based on Full Scale up to 5 A, Reading >5 A) Metered Parameter Accuracy ac Ampere Phase Voltage Watts Vars VA kw Hours kvar Hours kva Hours Power Factor Frequency Demand Table 3. Control Power Input +/- 0.5% +/- 0.5% +/- 2.0% +/- 0.1% Input IQ 310 IQ 320/330 Vac ±10% ±10% Frequency 50/60 Hz ±10% 50/60 Hz ±10% Range ac Burden 180 ma 180 ma Vdc ±10% ±10% dc Burden 7 W 7 W
4 Technical Data Page 4 Effective: March 2004 Metering Devices Field Wiring Connection Diagrams 3-Phase, 3-Wire (Up to 600 Volts) Proper CT polarity is critical to the proper operation of the meter. LINE L3 L2 L1 VA VB VC NEU PS1 PS2 Figure 1. 3-Phase, 3-Wire (Up to 600 Volts) H2A H2B H2C H1A H1B H1C Control Power LOAD Case ground must be connected for proper operation. IQ 320/330 IQ 310 LINE N L3 L2 L1 3-Phase, 4-Wire (Up to 600 Volts) Proper CT polarity is critical to the proper operation of the meter. Figure 3. 3-Phase, 4-Wire (Up to 600 Volts) H2A H2B H2C H1A H1B H1C LOAD Case ground must be connected for VA VB VC NEU PS1 PS2 proper operation. IQ 320/330 IQ 310 Control Power 3-Phase, 3-Wire (Above 600 Volts) Proper CT polarity is critical to the proper operation of the meter. LINE L3 L2 L1 Open Delta PT Connection H2A H2B H2C H1A H1B H1C VA VB VC NEU PS1 PS2 Control Power LOAD Case ground must be connected for proper operation. IQ 320/330 IQ 310 LINE L3 L2 L1 3-Phase, 4-Wire (Above 600 Volts) Proper CT polarity is critical to the proper operation of the meter. N WYE Connection H2A H2B H2C H1A H1B H1C VA VB VC NEU PS1 PS2 Control Power LOAD Case ground must be connected for proper operation. IQ 320/330 IQ 310 Figure 2. 3-Phase, 3-Wire (Above 600 Volts) Figure 4. 3-Phase, 4-Wire (Above 600 Volts)
5 Metering Devices Technical Data Effective: March 2004 Page 5 Dimensions 6.72 (170.7).50 (12.7).39 (9.9) Normal Program (260.4) Menu Scroll Enter.35 (8.9) Figure 5. Dimensions for the Display Module (Only)
6 Technical Data Page 6 Effective: March 2004 Metering Devices 6.72 (170.7).50 (12.7) 4.01 (101.9) Normal Program IQ 220/IQ (260.4) E18559 Menu Scroll Enter Figure 6. Dimensions for the Display Module with Base (All Models)
7 Metering Devices Technical Data Effective: March 2004 Page 7.78 (19.8) 3.55 (90.2) 2.00 (50.8).25 (6.4) 5.38 (136.7) 2.69 (68.3) Slot Size Rad. (4 places) 4.55 (115.6) 8.90 (226.1) 6.68 (169.7) 9.38 (238.3) 5.05 (128.3) 4.45 (113.0) 4.69 (119.1) 2.23 (56.6).06 (1.5) R 4 Places (Optional) 2.53 (64.3) 5.06 (128.5).218 (5.5) Diameter 10 Places Figure 7. Base Mounting Hole Pattern Figure 9. Display Mounting Hole Pattern DIN Clip Base Module DIN Rail L-Bracket Figure 8. Optional Base Mounting
8 Technical Data Page 8 Effective: March 2004 Metering Devices Product Selection Table 4. Features Feature Meter Catalog Number IQ310 IQ320 IQ330 IQ330M Voltage Sensing Range ANSI C12 Accuracy Power Supply Vac Vac Vac Vac Yes Yes Yes Yes Communications No INCOM INCOM Modbus RTU KYZ Output No Yes Yes Yes Digital Inputs No No 2 2 Digital Outputs No No 2 2 Analog Input No No 1 1 Anti-Tamper Seal No No Yes Yes Table 5. Ordering Information Description IQ 310 Complete Meter with Base Module, Display, and 14-inch (355.6 mm) Cable no communications, no pulse output IQ 320 Complete Meter with Base Module, Display, and 14-inch (355.6 mm) Cable with INCOM communications and pulse output IQ 330 Complete Meter with Base Module, Display, and 14-inch (355.6 mm) Cable with INCOM communications, pulse output, 2 contact outputs, 2 digital inputs, 1 analog input and anti-tamper seal IQ 330M Complete Meter with Base Module, Display, and 14-inch (355.6 mm) Cable with RS-485 Modbus communications, pulse output, 2 contact outputs, 2 digital inputs, 1 analog input and anti-tamper seal D Display Module Only 3 feet (0.9 m) Long CAT 5 Cable 6 feet (1.8 m) Long CAT 5 Cable 10 feet (3.0 m) Long CAT 5 Cable Catalog Number IQ310 IQ320 IQ330 IQ330M IQ300D IQ23CABLE IQ26CABLE IQ210CABLE CSA is a registered trademark of the Canadian Standards Association. Modbus is a registered trademark of Modicon, a division of Schneider Electric Industries SA. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL and CUL are federally registered trademarks of Underwriters Laboratories Inc. Eaton Electrical 1000 Cherrington Parkway Moon Township, PA USA tel: Eaton Corporation All Rights Reserved Printed in USA Publication No. / Z-2347 March 2004
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationMetering Devices IQ Analyzer 6400/6600 Series
Metering Devices IQ Analyzer 6400/6600 Series Technical Data Supersedes TD.17.02A.T.E pages 1-8 dated May 2000 Description Page General Description............................................. 2 Applications....................................................
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationFP-4000 Feeder Protection
FP-4000 Feeder Protection Technical Data TD02602007E Effective September 2007 Supersedes TD02602003E Pages 1 8, Dated March 2006 FP-4000 FP-4000 Product Description........................... 2 Application
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More informationPower-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationCurrent Transformers
Supersedes December 2002 General Description Eaton s low voltage current transformers are available in both solid core and split core designs. Engineered for electronic metering applications, all solid
More informationDigital and Analog I/O
70072-0127-07 TECHNICAL NOTE 02/2007 Digital and Analog I/O This document discusses the application and configuration of digital and analog inputs/outputs (I/O). Details are for both onboard I/O and external
More informationATC-300 Automatic Transfer Switch Controller
ATC-300 Technical Data New Information Technical Data Page 2 Effective: May 2004 ATC-300 Introduction The Cutler-Hammer ATC-300 from Eaton s Electrical business is a comprehensive, multi-function, microprocessor-based
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More information3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationMultilin EPM 6000. GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.
GE Grid Solutions Multilin EPM 6000 High Accuracy Power & Energy Measurement The Multilin EPM 6000 is one of the industry s highest performance revenue grade panel meters with superior cost to performance
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More information3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationInstallation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationCruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
More informationAIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
More informationAPC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
More informationPow-R-Con Multi Function Control
37264 Pow-R-Con Multi Function Control Product Specification Product Specification 37264 Product Information DYNA Power Controls Pow-R-Con TM GENERAL The Barber-Colman Pow-R-Con TM represents an integrated
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationPOWERLOGIC Circuit Monitor Series 2000
Class POWERLOGIC Circuit Monitor Series 2000 Features True rms metering Certified ANSI C2.6 revenue accuracy High accuracy 0.2% current and voltage Power quality readings THD, k-factor, crest factor Over
More informationPower quality monitoring and analysis with reliability
Power quality monitoring and analysis with reliability PowerLogic CM4000 series circuit monitors Buildings Industry Data Center Intelligent metering and control devices Whether in offices, classrooms,
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationCentro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationEaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationMultifunction devices
devices devices devices, electronic Type Page LED multifunction displays pulse, frequency, time (DC) Codix 524 240 pulse, frequency, time (AC+DC) Codix 544 243 LCD multifunction preset counters 1 or 2
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
More informationEasily connect your switchboards to facility management solutions
Easily connect your switchboards to facility management solutions Acti 9 communication system gives your customers complete control of their installations 100% exclusive to Schneider Electric Acti 9: The
More informationPolyphase kwh Electricity Meter
Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2
More informationDIGITAL SWITCHBOARD METERS
DIITAL SWITCHBOARD METER MODELS 2491, 2492, FEATURES The Model 2491 (Single function), Model 2492 (Dual function), and Model (Triple Function) Digital Switchboard Meters were developed to provide customers
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationProduct Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
More informationGain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationApplications. Remote Display Mounting Kits
June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationTable of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
More informationSmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
More informationSmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationPIEZOMETER AIRFLOW MEASURING RING
PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationFoxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationCommunicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationSeries 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS
Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design
Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationPowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
More informationSTRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationSmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
More informationHMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
More informationSmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
More informationFrequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
More informationIndoor / Outdoor Antenna
z300 High Precision NTP Time Server Indoor / Outdoor Antenna High Precision NTP Time Server with PoE (Indoor or Outdoor use) synchronized by GPS Revision 4 ZTI / 1 boulevard d'armor / BP 20254 / 22302
More informationNRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting
NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability 4-rate, temperature-compensated
More informationC13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
More informationXFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications
The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible
More informationScan QR Code for more information. SEM 3 - Embedded Micro Metering Module. User Manual. Answers for infrastructure and cities.
Scan QR Code for more information SEM 3 - Embedded Micro Metering Module User Manual Answers for infrastructure and cities. SEM3 - Embedded Micro Metering Module The use of unauthorized parts in the repair
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationProducts and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
More informationRepeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationIndustrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationDaker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More informationIndustrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
More information