Advanced hotel systems

Size: px
Start display at page:

Download "Advanced hotel systems"

Transcription

1 Advanced hotel systems

2 AVE Since 1904, the days of my great grandfather, we have been key players in uncountable technological evolutions. However, 2008 definitely marked a turning point, the beginning of a new era. The object you are holding in your hands right now is the fruit of a journey characterised by research, innovation, investments and passion which bore DOMINA HOTEL. DOMINA HOTEL marks an important development with respect to hotel industry standards. DOMINA HOTEL represents cutting-edge research solutions and advanced design flexibly fully meeting hotel management needs ranging from small hotels to the large multinational hotel chains. An Ave tagged revolution, I am proud to say, entirely made in Italy. Welcome to Ave. Dott. Alessandro Belli President of AVE s.p.a. 2

3 A totally innovative solution based on invisible modules sensitive to touching the surface of the glass plate, provided with LEDs and tactile sensors. pag 4 Series characterised by design evolution and various technological features, available in a wide range of aesthetic properties. pag 8 Series conceived in the spirit of traditional and functional design, with technological solutions suitable for any environment, currently incorporating all System 44 innovations. Technical catalogue pag 10 pag 14 3

4 AVE patents n AVE TOUCH Just one touch to step into a new era, the past fades away, simply outlived. Ave Touch comes in an awesome range of products adorning the most advanced technology with physical beauty, tactile. Ave touch obeys your orders, turning dreams into desires. Touch, listen and watch the environment you yearned for finally takes shape. AVE TOUCH With sliding cover for sockets AVE TOUCH Sign with graphic step-marker function, interchangeable and customizable with hotel logo. 4

5 Customizable room access client card. AVE TOUCH 3+3 With room transponder reader customizable with room number and hotel logo 5

6 AVE patents n AVE TOUCH switches With interchangeable and customizable symbols Customizable with hotel logo AVE TOUCH signs With interchangeable and customizable symbols Customizable with hotel logo 6

7 AVE TOUCH Wall-lined installation A special box allows perfect wall-lined installation, leaving only the magnificent Ave Touch surface exposed. AVE TOUCH switches With regulation of sensitivity to touch Customizable with hotel logo 7

8 AVE patents n 196 LIFE 44 Choice and appreciation are innate traits of human beings. Ave Life 44 meets this need by combining technology with design and selected materials. An authentic treat for your eyes. LIFE 44 Extractable emergency lamp Glass VERA 44 front plate customizable with hotel logo 8

9 Switches Fibre optics illuminated frame Glass VERA 44 front plate Ideal combination with AVE TOUCH devices Customizable with hotel logo. The glass plate that ushers a touch of elegance into any room. Metal ZAMA 44 front plate Paintable and customizable with hotel logo. Classy frame for breathtaking environments. LIFE 44 Electronic thermostat 9

10 AVE patents n 196 Switches PERSONAL 44 front plate customizable with software Programmable thermostat 10

11 External sign PERSONAL 44 front plate Customizable with software Sockets PERSONAL 44 front plate customizable with software 11

12 Brevetti AVE n DOMUS 100 Gratifying simplicity. Combining a wide range of colours and functionalities DOMUS 100 is the perfect key to a lively and blissful system. Step-marker PERSONAL 44 front plate customizable with software Personal 44 with modern design, comes in a wide range of technological colours and with mirror effect, also available in transparent version with customizable graphic and colours. Graphic customization may also be performed by the end client by means of a software available at our website www. ave.it free of charge. Extractable emergency lamp Glass VERA 44 front plate customizable with hotel logo Switch Metal ZAMA 44 front plate Customizable with hotel logo 12

13 Dimmer 44 MOULDED front plate Customizable with hotel logo 44 Moulded suitable for any environment, it also incorporates all the System 44 innovations. Consumer unit Coordinated with the System 44 front platess Customizable with hotel logo VERA 44 for round box Best for restoration Customizable with hotel logo Shaver socket Glass VERA 44 front plate Customizable with hotel logo 13

14 14

15 Elettricità Evoluta dal 1904 Technical catalogue contents Stand-alone system: 125kHz technology... page 20 MIFARE technology... page kHz and MIFARE technology common products... page 32 Network system: MIFARE technology... page 38 Network and stand-alone systems common products... page 48 Codes summary: Stand-alone system... page 52 Network system... page 53 Compatibility with S45... page 54 Installation examples: Stand-alone systems... page 58 network systems... page 62 Hotel room radio components... page 66 Electrical Schematics... page 70 15

16 Domina Hotel, one system RELIABILITY AVE hotel system is not just about aesthetic, it is also reliability. Each room can be monitored by a central computer at the reception. However, in case of computer failure, the whole system operates as usual, losing only the remote room monitoring while awaiting repair of the failure. The system is at its best when it operates in its entirety but each device continues operating independently even in case of failure of the other components. Furthermore, the islands system, wherein each room not only operates independently but is also connected to the main network, ensures that no independent failure brings the entire hotel system to a standstill. TECHNOLOGY AVE hotel management products use the contactless Mifare and 125kHz technology. The access cards are entirely safe and clone-proof thus leaving you and your clients entirely sure that no ill-intentioned person will have an easy time in your premises. The possibility to integrate e-money systems (not provided by AVE) allows you to offer your clients an entirely new range of services, accessible through the same card which shall also serve as a payment system. AESTHETIC TOUCH: The plates are entirely customizable and configurable to suit your needs. Furthermore, they can bear, depending on the model, your hotel logo, room number and any other indication adding a personalised and unique classy touch to your hotel. Plates and devices made of various material and finishing are available. 16

17 Elettricità Evoluta dal 1904 for all hotel needs EFFICIENCY AND ENERGY SAVING Constant monitoring from the reception shall keep you constantly informed, allowing you to intervene promptly to curb poor quality services. Furthermore, Domina Hotel allows optimising management and keeping energy consumption under control allowing considerable saving. This implies greater customer satisfaction, a more efficient hotel and lower running costs. SCALABILITY AVE Domina Hotel systems suits all needs, both in terms of costs and performance. We have a simple and inexpensive system for small hotel operators, extremely suitable for an environment not requiring particularly sophisticated solutions. The bigger the hotel the more our system meets your ever-growing needs up to providing a complete network system for monitoring the rooms and any type of environment, even in big hotels. If you expect to expand with time, no need to worry we have the right solution for you. As a matter fact, the AVE Domina Hotel system requires just a few updates to match the growth of your business without forcing you to start from scratch, helping you preserve your investments over time. COMFORT AVE hotel devices are client-oriented, offering utmost comfort during his stay at your hotel. The thermostat, which is easy to use and intuitive, allows regulating the room temperature. The signalling system allows the client to decide when and whether to be disturbed. The room service personnel cannot ring the doorbell or open the door by mistake while the client is in the room. The remote control allows the client to operate the devices (loads) comfortably from his seat. 17

18 18

19 Elettricità Evoluta dal 1904 Hotel management stand-alone 19

20 Stand-alone system with 125kHz technology 53GA72-T External reader 441GA01-T 442GA01-T External readers are devices which, by means of a transponder card, allow controlling access to hotel rooms and premises. These readers are capable of independently managing their entries and exits in such a manner to be able to operate even without requiring other devices of the same hotel series. The devices may be configured for access to 4 different types of areas: ROOMS: access allowed for all enabled client cards and for the service personnel cards at given conditions (e.g. the room service personnel card operates only when the room is not occupied). SERVICE ROOMS: access allowed for service personnel cards but not for the client cards. COMMON AREAS: access allowed both for service personnel and client cards SCALABLE GND A B 12V ACCESS: access allowed BUS AVE GND ARMBUS for enabled service DISTURB personnel cards. For BATT access, client cards require sufficient credit BUS consisting in a number of accesses. The device updates the card reducing the credit at PROG each access. 53GA72-T Made in Italy BATTERY 3V CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT FEM Clima Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Blue LED light for identification in the dark Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. Transponder Technology Means: ISO7816 (credit card format) Transponder: RFID 125kHz Opt64 Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN Ver (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN Ver ( ) - ETSI EN Ver ( ) - EN : A1: A2:2007 LVD 2006/95/EEC. In compliance with EN :2006 harmonised standards Auxiliary relay outputs Maximum applicable load (resistive A.C.): 250Vac (cosϕ 1) Maximum applicable load (CC): 30Vdc Maximum applicable load (inductive A.C.): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency: cycles/hr. OVERALL DIMENSIONS 441GA01-T DISTURB 8 45 mm 7 Made in Italy (3)A 230V~ Court. 2 Court V BUS 6 mm B A 20 67,5 mm 55,5 mm

21 Stand-alone system with 125kHz technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA01-T Transponder-equipped external reader - 125kHz 3 Domus 100 series 442GA01-T Transponder-equipped external reader - 125kHz 3 Life44 series 441GA01-T 442GA01-T DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green A RS B Green B RS Black - Supply (Common inputs) + Black + Supply V 1 Green Room status Input Made in Italy 5(3)A 230V~ Court. Court. BUS 2 Green Courtesy Light Input 3 e 4 Green Courtesy Light Output 6 mm B A 5 Green Common for Terminals 6, 7 and 8 6 Green Electric Lock Output 7 Green Bell Output 8 Green Guest In Output 21

22 Stand-alone system with 125kHz technology 53GA72-T 441GA01-T Internal reader (room) 441GA30-T 442GA30-T Internal readers are devices to be positioned inside the premises to be managed to allow 1actuation of 5 room 6 7loads 8 9 and 10 services + GND A B 12V only in presence of an enabled card. Such BUS AVE GND ARMBUS DISTURB readers are capable of independently managing their inputs and outputs in such a BATT BUS manner to be able to operate even without requiring the other devices of the same hotel PROG series. Furthermore, they BATTERY are 3Vcapable of communicating 53GA72-Twith other devices such as room CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT control Made in Italyunit, transponder card external reader (for access to premises), FEM Clima environment thermostat and 11transponder card 15 16program- mer. 17 The readers are provided with two auxiliary inputs for detecting the state of dry contacts (voltage free contacts) and with four output relays (still for dry contact). Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): DISTURB _ 80mA Maximum absorption (@ +12Vdc): _ 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): _ 200mArms Maximum absorption (@ 12Vac): _ 250mArms OVERALL DIMENSIONS Mechanical features Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: poles 12A -250V Programming connector: JFemale stereo jack d=2.5mm Blue LED light for identification in the dark Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. Transponder technology Means: ISO7816 (credit card format) Transponder: RFID 125kHz Opt64 Compliance with standards 1999/5/EC Directive Made of Class 1. In compliance with ETSI EN Ver (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN Ver ( ) - ETSI EN Ver ( ) - EN : A1: A2:2007 LVD 2006/95/EEC. In compliance with EN :2006 harmonised standards Auxiliary relay output Maximum applicable load (resistive A.C.): 250Vac (cosϕ 1) Maximum applicable load (CC): 30Vdc Maximum applicable load (inductive A.C.): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electric) frequency: 12V 1200 cycles/hr5(3)a 230V~ Court. Court. Duration of contact (mechanical): Made in Italy manoeuvres 6 mm Maximum switching (mechanical) B frequency cycles/hr. + - BUS A 441GA30-T DISTURB DISTURB A B 45 mm BUS 12V Made in Italy 6 mm Clima FEM DISTURB 5(3)A 230V~ ,5 mm 55,5 mm

23 Stand-alone system with 125kHz technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA30-T Transponder-equipped external reader with pocket 3-125kHz Domus 100 series 442GA30-T Transponder-equipped external reader with pocket 3-125kHz Life44 series 441GA30-T V 442GA30-T 5(3)A 230V~ Court. Court. BUS Made in Italy 6 mm B A DESCRIPTION OF TERMINAL BOARD A B BUS 12V - + Made in Italy 6 mm Clima FEM DISTURB 5(3)A 230V~ Terminal Colour Description A Green A RS-485 B Green B RS Black - Supply (Common inputs) + Black + Supply 1 Green Room Light Input 2 Green Window Contact Input 3 e 4 Green Room Light Output 5 Green Common for Terminals 6, 7 and 8 6 Green Air Conditioner Enabling Input 7 Green Load Control Output (EMF) 8 Green DISTURB Output 23 A B Made in Italy 6 mm

24 Stand-alone system with 125kHz technology Card programmer SCR-ALB04 Item SCR-ALB04 is a transponder card programmer (125KHz) capable of communicating with the hotel series devices. SCR-ALB04 is provided with a USB interface (compatible with 1.1 and 2.0 USB specifications), which allows directly interfacing the programmer to a monitoring PC for programming the transponder card and/or programming all 125kHz hotel management devices. In order for item SCR-ALB04 to operate, it is required to be connected to a PC provided with a special card programming software supplied as a kit. There are two types of software: the first basic one intended for the end user and a more technical one meant for installers and/or technical assistance centres. Light signals (LEDs) L1 (Red): NOT EXEC Indicates that the last command sent has not been executed correctly. L2 (Green): EXECUTED Indicates that the last command sent has been executed correctly L3 (Yellow): WAIT Indicates that the programmer is free and ready to receive new commands (blinking) Card 44339CHM-T 44339CHU-T The 125kHz cards used for hotel management are provided with a rewritable memory equivalent to 1kb CHM-T Card master The system is conceived to use a Master card in order to be able to perform any card preparation and/or programming operation. This Master card has its own unambiguous code called Hotel Code which is transferred to the reader through the same Master in the direct programming step alongside any other required data and a 24 or that it is completing the execution of a previous command (fixed light). L4 (Yellow): TX Indicates that a communication from the SCR-ALB04 programmer to the PC through interface is in progress. L5 (Yellow): RX Indicates that a communication from the PC to the SCR-ALB04 programmer through interface is in progress. Electrical features Supply voltage (DC): +5Vdc ±10% self supplied through USB port Stand-by absorption (@ +5Vdc): 50mA Maximum absorption (@ +5Vdc): 100mA USB interface compatibility: USB1.1/2.0 Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. Progressive Room Code automatically increased by the reader after the first configuration. Systems divided into several zones and/or several sub-systems may be built. In this case, the system must be provided with a Master card for each of the predetermined combinations (e.g. 3 zones and 2 subsystems = 6 Master cards). NOTE: The Master card (or Master cards) serves as an identification for the system and it should be preserved with care for possible future configurations. The system code received by the Master card (alongside the sub-system code and zone code), is memorised by the reader and, during the client and/or service per- Mechanical features Container: 123 l x 30 h x 68 d mm Material: ABS (UL 94 HB) Colour: Black (Ral 9005) Degree of protection: IP40 PC interface: USB 1.1/2.0 (Type B connector) ARMBus interface: Stereo Jack 2.5mm Compatible with all 125kHz hotel system elements Operating mode The SCR-ALB04 transponder card reader/programmer may be used both as a simple device for programming transponder cards used for 125kHz hotel management (alongside a user software) and in combination with a further software (meant for technicians and/or installers), as a programmer for all modules made for hotel management. As a matter of fact, it allows updating management firmware and/or modifying configuration parameters of the various devices of the 125kHz hotel series. Furthermore, it allows monitoring traffic both on the room Bus (Sniffer) bearing all the messages and/or commands circulating in the Bus itself. sonnel card programming step, it is transferred on all the programmed cards through the reader itself. In case of failure or lack of the SCR-ALB04 programmer, all the access card programming operations may be performed by using the Master card, following procedures outlined in the reader instructions CHU-T User card User cards allow access to or use of a service. These cards are of the following types: CLIENT, ROOM SERVICE PER- SONNEL, MAINTENANCE PERSONNEL, PASSEPARTOUT, SUPER-GUEST, SUB-MASTER, MASTER COPY, ERASER.

25 Stand-alone system with 125kHz technology Elettricità Evoluta dal 1904 Cod. Description Modules SCR-ALB04 Transponder card programmer 125kHz - SFW-ALB04 software included SFW-ALB04 Card generation software Generates a 125kHz or MIFARE card depending on - the programmer used SCR-ALB04 SFW-ALBTECSystem configuration software for technicians and installers - EXAMPLES OF SCREENSHOTS ROOM STATUS: AVE stand-alone system software allows a constant update on which rooms are reserved and for how long. Management of the rooms allows monitoring the situation and avoiding unpleasant inefficiency for the clients as well creating client cards with expiry dates.. PERSONNEL MANAGEMENT: Personnel management allows constant monitoring of the situation and generating premises access cards allowing the hotel personnel to perform its duties in an easy manner. The room service personnel may enter the rooms for cleaning and tidying, but only when the room is not occupied by the client hence avoiding unpleasant inconveniences. The maintenance personnel shall have access to all premises without restrictions except for the rooms occupied by the clients. Cod. Description Modules 44339chm-t 125kHz Master Transponder Card - Card format: ISO chm-t 44339chU-t 125kHz User Transponder Card - Card format: ISO chU-t 25

26 Stand-alone system with MIFARE technology 53GA72-T External reader (room) 441GA01-M 442GA01-M External readers are devices which, through the use of MIFARE cards, allow controlling access to the hotel rooms and premises, and they are capable of operating even without requiring other devices of the same hotel series. MIFARE technology allows generating cards having higher security level and integrating advanced services (e-money) therein with topmost level reading performance. The devices may be configured for access to 4 different types of areas: ROOMS: access allowed for all enabled client cards and for the service personnel cards at given conditions (e.g. the room service personnel card operates only when the room is not occupied). SERVICE ROOMS: access allowed for service personnel cards but not for the client + cards. GND A B 12V AVE BUS GND ARMBUS COMMON AREAS: access allowed both BATT for service personnel and DISTURB BUS client cards. SCALABLE ACCESS: access allowed PROGfor enabled service personnel cards. For access, CR2032 client cards require BATTERY ONLY 3V sufficient 53GA72-Tcredit consisting in a number UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT Made in Italy of accesses. The device updates the FEM Clima card reducing the credit at each access Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) for the Domus 100 series and Life44, while the AveTouch 442GA02-M code is beneath the components wire Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: poles 12A - 250V Programming connector: Female Stereo Jack d=2.5mm Blue light for identification in the dark MIFARE technology Means: ISO7816 (Credit card format) Transponder: 13.56MHz MIFARE RFID (ISO type A standard) Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. Auxiliary relay outputs Maximum applicable load (resistive A.C.): 250Vac (cosϕ1) Maximum applicable load (CC): 30Vdc Maximum applicable load (inductive A.C.): 250Vac (cosϕ0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency cycles/hr. Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN Ver (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN Ver ( ) - ETSI EN Ver ( ) - EN : A1: A2:2007 LVD 2006/95/EEC. In compliance with the EN :2006 harmonised standards OVERALL DIMENSIONS OVERALL DIMENSIONS 441GA01-T DISTURB mm Made in Italy (3)A 230V~ Court. 2 Court V BUS 6 mm B A 26 67,5 mm 55,5 mm

27 Stand-alone system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA01-M External reader MIFARE 3 Domus 100 series 442GA01-M External reader MIFARE 3 Life44 series 441GA01-M 442GA02-M External reader AVETouch MIFARE 3 AVETouch series 442GA01-M 442GA02-M 442GA02-M application examples Available upon request DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green A RS B Green B RS Black - Supply (Common inputs) V + Black + Supply 1 Green Room Status Input Made in Italy 5(3)A 230V~ Court. Court. BUS 2 Green Courtesy Light Input 3 e 4 Green Courtesy Light Output 6 mm B A 5 Green Common for Terminals 6, 7 and 8 6 Green Electric Light Output 7 Green Bell Enabling Output 8 Green Guest IN Output 27

28 Stand-alone system with MIFARE technology Internal reader (room) 53GA72-T 441GA01-T 441GA30-M + GND A B 12V AVE BUS ARMBUS 442GA30-M DISTURB Internal BATT readers are devices to be positioned inside BUS the premises to be managed to allow actuation of room loads and services only in presence of an enabled card. Such readers PROG are capable of operating even without requiring other CR2032 BATTERY devices ONLY 3V of the same hotel 53GA72-T series. MIFARE Made in Italy technology allows generating cards FEM Clima having higher security level and integrating advanced services 11 12(e-money) therein with topmost level reading performance. Furthermore, they are capable of communicating with other devices such as room control unit, external reader, environment thermostat and MIFARE card programmer. The readers are provided with two auxiliary inputs for detecting the state of dry contacts (voltage free contacts) and with four output relays (still dry contact). Electrical features DISTURB With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms Mechanical features Container: 3 S44 modules GND UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of low-absorption high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: poles 12A - 250V Programming connector: Female Stereo Jack d=2.5mm Blue light for identification in the dark Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. MIFARE technology Means: ISO7816 (Credit Card format) Transponder: 13.56MHz MIFARE RFID (ISO type A standard) Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. According to ETSI EN Ver (2006-4) harmonised standards EMC Directive 2004/108/EC. According to the following harmonised standards: - ETSI EN Ver ( ) - ETSI EN Ver ( ) - EN : A1: A2:2007 LVD 2006/95/EEC. According to EN :2006 harmonised standards: Auxiliary relay outputs Maximum applicable load (resistive A.C.): 250Vac (cosϕ 1) Maximum applicable load (CC): 30Vdc Maximum applicable load (inductive A.C.): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency cycles/hr. 8 7 Made in Italy 6 mm (3)A 230V~ Court. 2 Court BU B OVERALL DIMENSIONS 441GA30-T DISTURB DISTURB 45 mm A B BUS 12V Made in Italy 6 mm Clima FEM 5(3)A 230V~ ,5 mm 55,5 mm

29 Stand-alone system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA30-M Internal reader with pocket - MIFARE 3 Domus 100 series 442GA30-M Internal reader with pocket - MIFARE 3 3 Life44 series 441GA30-M V 442GA30-M 5(3)A 230V~ Court. Court. BUS Made in Italy 6 mm B A DESCRIPTION OF TERMINAL BOARD A B BUS 12V - + Made in Italy 6 mm Clima FEM DISTURB 5(3)A 230V~ Terminal Colour Description A Green A RS-485 B Green B RS Black - Supply (Common inputs) + Black + Supply 1 Green Room Light Input 2 Green Window Contact Input 3 e 4 Green Room Light Output 5 Green Common for Terminals 6, 7 and 8 6 Green Air Conditioner Enabling Input 7 Green Load Control Output (EMF) 8 Green DISTURB Output 29 A B Made in Italy 6 mm

30 Stand-alone system with MIFARE technology Card programmer SCR-ALBM1 Item SCR-ALBM1 is a MIFARE card programmer capable of communicating with the hotel series devices. SCR-ALBM1 is provided with a USB interface (compatible with 1.1 and 2.0 USB specifications), which allows directly interfacing the programmer to a monitoring PC for programming cards and/or for monitoring and/or programming all MIFARE hotel management devices. In order for item SCR-ALBM1 to operate, it is required to be connected to a PC provided with a special card programming software supplied as a kit. There are two types of software: the first basic one intended for the end user and a more technical one meant for installers and/or technical assistance centres Light signals (LEDs) L1 (Red): NOT EXEC Indicates that the last command sent has not executed correctly. L2 (Green): EXECUTED Indicates that the last command sent has been executed correctly L3 (Yellow): WAIT Indicates that the programmer is free and ready to receive new commands (blinking) or that it is completing the execution of a Card 44339CHM-M 44339CHU-M MIFARE cards used for hotel management are provided with a rewritable memory equivalent to 1kb CHM-M Card master The system is conceived to use a Master card in order to be able to perform any card preparation and/or programming operation. This Master card has its own unambiguous code called Hotel Code which is transferred to the reader through the same Master in the direct programming step alongside any other required data and a 30 previous command (fixed light). L4 (Yellow): TX Indicates that a communication from the SCR-ALBM1 programmer to the PC through interface is in progress L5 (Yellow): RX Indicates that a communication from the PC to the SCR-ALBM1 programmer through interface is in progress. Electrical features Supply voltage (DC): +5Vdc ±10% self supplied through USB port Stand-by absorption (@ +5Vdc): 50mA Maximum absorption (@ +5Vdc): 100mA USB interface compatibility: USB1.1/2.0 Climatic conditions Temperatura ed umidità relativa di riferimento: 25 C UR 65% Range operativo di temperatura: 0 C +40 C Umidità Relativa massima: +35 C Altitudine massima: 2000m s.l.m. Mechanical features Container: 123 l x 30 h x 68 d mm Progressive Room Code automatically increased by the reader after the first configuration. Systems divided into several zones and/or several sub-systems may be built. In this case, the system must be provided with a Master card for each of the predetermined combinations (e.g. 3 zones and 2 subsystems = 6 Master cards). NOTE: The Master card (or Master cards) serves as an identification for the system and it should be preserved with care for possible future configurations. The system code received by the Master card (alongside the sub-system code and zone code), is memorised by the reader and, during the client and/or service per- Material: ABS (UL 94 HB) Colour: Black (Ral 9005) Degree of protection: IP40 PC interface: USB 1.1/2.0 (Type B connector) ARMBus interface: Stereo Jack 2.5mm Operating mode The SCR-ALBM1 transponder card programmer may be used as a simple device for programming cards used for MIFARE hotel management, both in stand-alone and in network mode or in combination with a further software (meant for technicians and/or installers), as a programmer for all modules made for hotel management. As a matter of fact, it allows updating management firmware and/or modifying configuration parameters (resident in EEPROM) of the various devices of the MIFARE hotel series. Furthermore, it allows monitoring traffic both on the room Bus (Sniffer) bearing all the messages and/or commands circulating in the Bus itself. sonnel card programming step, it is transferred on all the programmed cards through the reader itself. In case of failure or absence of SCR-ALBM1 programmer, all the access card programming operations may be performed by using the Master card, following procedures outlined in the reader instructions CHU-M User card User cards allow access to or use of a service. These cards are of the following types: CLIENT, ROOM SERVICE PER- SONNEL, MAINTENANCE PERSONNEL, PASSEPARTOUT, SUPER-GUEST, SUB- MASTER, MASTER COPY, ERASER

31 Stand-alone system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules SCR-ALBM1 MIFARE card programmer - SFW-ALB04 software included SFW-ALB04 Card generation software Generates a 125kHz or MIFARE card depending - on the programmer used SCR-ALBM1 SFW-ALBTEC System configuration software for technicians and installers - Notes : - the encoder and MIFARE cards operate both in stand-alone systems and in network modes -for further details on SFW-ALB04 software see page 25 Cod. Description Moduli 44339chm-M MIFARE Master Card - Card format: ISO chU-M MIFARE User Card - Card format: ISO chm-M 44339chU-M 31

32 Thermostat Stand-alone system 125kHz and MIFARE technology common products 441GA52-T 442GA52-T The thermostat is used for detecting environment temperature and management of the thermoregulation of a hotel room or other premises in general. The thermostat is capable of independently managing its inputs and outputs. Furthermore, the thermostat is capable of communicating with the other devices such as the room control centre, external reader, internal reader and card both 125kHz and MIFARE programmer. This device is provided with two live analogic auxiliary inputs (+5Vdc) for detecting resistive values (room/window status and water temperature) and with four dry contact relay outputs. In addition, it is capable of managing both heaters and fan-coils. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 50mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 75mArms Maximum absorption (@ 12Vac): 200mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 6.5 mm (from plate wire) Degree of protection: IP40 Terminal boards: poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Compatible with all System 44 elements. Temperature detection Measurement range: from 0 C to 40 C Regulation range: 30 C (from 5 C to 35 C) Reproducibility error: 0.2 C (max) Consistency: 0.3 C (max) Thermostat differential: from 0.2 C to 2,5 C to 2.5 C adjustable Display in C or F Compliance with standards IEC/EN : automatic electrical controls for household and similar use (Part 1 - general requirements) IEC EN : automatic electrical controls for household and similar use (Part Particular requirements for control devices sensitive to temperature) Auxiliary relay output Maximum applicable load (resistive): 250Vac (cosϕ 1) Maximum applicable load (inductive): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electrical) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency: cycles/ hr. DESCRIPTION OF DISPLAY ARMBUS ADDRESS: used only during programming step NIGHT SAVING: thermostat in night saving mode 32 OVERTEMPERATURE: overtemperature control enabled ANTIFREEZE: antifreeze control enabled BUS: system connected to Bus KEY LOCK ENABLED SUMMER: thermostat in summer mode. If blinking it means the window is open INTERMEDIATE : mild season mode. If blinking it means the window is open WINTER: winter mode. If blinking it means the window is open SAVING MODE: foperating time controlled by external clock FAN COIL: air conditioner enabled (fan symbol). The vertical bar indicates the fan-coil speed. OFF REGULATION: thermoregulation disabled manually. Antifreeze and overtemperature functions remain enabled ANTIFREEZE: antifreeze function enabled (valve open and fan speed 1) TEMPERATURE MEASUREMENT UNIT: C = degrees Celsius F = degrees Fahrenheit E = temperature out of range

33 V BUS 5(3)A 230V~ Court. Court. Stand-alone Made in Italy 6 mm system 125kHz and MIFARE technology common products B A Elettricità Evoluta dal 1904 A B BUS 441GA52-T 12V Made in Italy 6 mm 5(3)A 230V~ Clima FEM Cod. Description Modules 441GA52-T Saving thermostat with fan-coil or heaters regulation for stand-alone hotel management system 3 - Domus 100 series 442GA52-T Saving thermostat with fan-coil or heaters regulation for stand-alone hotel management system 3 - Life44 series DISTURB Note: 8 by connecting the 53GA91-T temperature probe to the thermostat, you obtain the automatic summer/winter switching GA52-T DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green A RS-485 A B Made in Italy 6 mm B Green B RS Black - Supply (Common inputs) BUS 12V 2(2)A 230V~ Black + Supply 1 Green Window Contact/Room status Input 2 Green Water Probe Input 3 e 4 Green Valve Output Green Common for Terminals 6, 7 and 8 6 Green Fan Coil Speed 1 Output 7 Green Fan Coil Speed 2 Output 8 Green Fan Coil Speed 3 Output DESCRIPTION OF THE BUTTON PANEL Enables/disables environment thermoregulation Decreasing the temperature set-point by 0.1 C steps Increasing the temperature set-point by 0.1 C steps Regulates the fan-coil speed 33

34 Room Control Unit Stand-alone system 125kHz and MIFARE technology common products 53GA72-T Article 53GA72-T is a room control unit to complete the transponder stand-alone hotel range of products. 53GA72-T is capable of independently managing its outputs and inputs as well communicating with various slave devices of the same hotel series (external reader, internal reader and environment thermostat) or with a possible master device (monitoring PC connected to the Bus through the SCR-ALB04 or SCR- ALBM1 programmer. The 53GA72-T room control unit is provided with four auxiliary imputs for detecting the state of dry contacts and of four relay outputs. It is provided with an internal clock (RTC or REAL TIME CLOCK) with lithium buffer battery which allows complete management of a clock/calendar required in case one wants to use the expiry function of the cards and/or the night saving function of the thermostat. The control unit has two LEDs at the front. The LEDs indicate the following: LED green (BATT): supply status of the device. If ON with fixed light it indicates that all is OK. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 75mA Maximum absorption (@ +12Vdc): 200mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 150mArms Maximum absorption (@ 12Vac): 300mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l Mechanical features Container: 4 S44 modules (69.5 l x 89.5 h x 65 d) mm Degree of protection: IP40 Terminal boards: 10 poles + 8 poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Compliance with standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards - EN : A1: A2:2007 LVD 2006/95/EEC. In compliance with the EN :2006 harmonised standards OVERALL DIMENSIONS GND A B 12V ARMBUS AVE BUS DISTURB GND BATT BUS PROG 89,5 mm 53GA72-T 53GA72-T Made in Italy BATTERY 3V CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT FEM Clima ,5 mm 65 mm

35 Stand-alone system 125kHz and MIFARE technology common products Elettricità Evoluta dal 1904 Cod. Description Modules 53GA72-T Room control unit for stand-alone systems 4 DIN GA-RTC Portable device for setting date and time - 53GA72-T TERMINAL BOARD Terminal Colour Description GND A B 12V ARMBUS BATT BUS AVE BUS DISTURB GND 1 Green - Supply 2 Green A RS Green B RS Green + Supply 5 Green AveBus + 6 Green Electric Lock Input 53GA72-T PROG 53GA72-T Made in Italy BATTERY 3V CR2032 ONLY UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT FEM Clima Green Room Light 2 Input 8 Green DISTURB Input 9 Green Air Conditioner 2 Enabling Input 10 Green Common Inputs and AVEBus (GND) 11 e 12 Green Electric Lock command Output 13 Green Room Light 2 command Output 14 Green Loads (EMF) 2 Switch Output 15 Green Air Conditioner 2 Enabling Switch Output NC contact 16 Green Air Conditioner 2 Enabling Switch Output NO contact 17 Green Common for Terminals 13, 14, 15 and GA01-T DISTURB 8 7 Made in Italy (3)A 230V~ Court. 2 Court V BUS 6 mm

36 36

37 Elettricità Evoluta dal 1904 Network hotel management 37

38 Network system with MIFARE technology 53GA72-T External reader 441AR01-M 442AR01-M The external readers in network are devices which, by means of MIFARE card, allow controlling access to rooms and hotel premises. External readers are capable of communicating with the room control unit, and they are driven by the latter through a monitoring central station. Such readers are provided with two auxiliary inputs for detecting the status of the dry contacts (voltage free) and four relay inputs (still dry contact). External readers are provided with a non-volatile memory for personalising some operating parameters (e.g. duration of the electric locking command) GND A B 12V AVE BUS ARMBUS DISTURB Electrical features With DC BATTpower supply Supply BUS voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA PROG With AC power supply CR2032 Supply voltage: BATTERY ONLY 12Vac 3V ±30% 53GA72-T Allowed supply frequency: 50 60Hz UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT Made in Italy Stand-by absorption (@ 12Vac): 200mArms FEM Clima Maximum absorption (@ 12Vac): 250mArms GND Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) for the Domus 100 and Life44 series, while the AveTouch 442GA02-M code is beneath the components wire. Active area lighting: by means of high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: poles 12A - 250V Programming connector: Female Stereo Jack d=2.5mm Compatible with all System 44 elements Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. MIFARE technology Means: ISO7816 (Credit card format) Transponder: 13.56MHz MIFARE RFID (ISO type A standard) Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN Ver (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN Ver ( ) - ETSI EN Ver ( ) - EN : A1: A2:2007 LVD 2006/95/EEC. In compliance with the EN :2006 harmonised standards. Auxiliary relay outputs Maximum applicable load (resistive A.C.): 250Vac (cosϕ 1) Maximum applicable load (CC): 30Vdc Maximum applicable load (inductive A.C.): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency cycles/hr. OVERALL DIMENSIONS 441GA01-T DISTURB mm Made in Italy (3)A 230V~ Court. 2 Court V BUS 6 mm B A 38 67,5 mm 55,5 mm

39 Network system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA01-M External reader MIFARE 3 Domus 100 series 442GA01-M External reader MIFARE 3 Life44 series 441GA01-M 442GA02-M External reader AVETouch MIFARE 3 AVETouch series 442GA01-M 442GA02-M 442GA02-M Application examples Available upon request DESCRIPTION OF TERMINAL BOARD Terminal Colour Description A Green Pole A Line RS B Green Pole B Line RS Black Negative Supply (Common Inputs) V + Black Positive Supply 1 Green Input (e.g. Room status detection) 5(3)A 230V~ BUS 2 Green Input (e.g. Courtesy Light) Made in Italy 3 e 4 Green Output (e.g. Courtesy Light) 6 mm B A 5 Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Electric lock) 7 Green Output (e.g. Bell) 8 Green Output (e.g. Guest In ) 39

40 Network system with MIFARE technology Internal reader (room) 53GA72-T 441GA01-T 441AR30-M + GND A B 12V AVE BUS ARMBUS 442AR30-M DISTURB Internal BATT readers in network are devices to be positioned BUS inside the premises to be managed to allow actuation of room loads and services only in presence of an PROG enabled card. External readers are capable of communicating BATTERY 3V with the room 53GA72-T control unit, and they are driven by CR2032 ONLY the latter through a monitoring central Made in Italy station. FEM Clima Such readers 11are 12 provided with 16 two 17 auxiliary inputs for detecting the status of dry contacts (voltage free) and four relay outputs (still dry contact). Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 80mA Maximum absorption (@ +12Vdc): 150mA With AC power supply DISTURB Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 200mArms Maximum absorption (@ 12Vac): 250mArms GND UNITA' CONTROLLO CAMERA / ROOM CONTROL UNIT Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 9 mm (from plate wire) Active area lighting: by means of high-efficiency blue LEDs Degree of protection: IP 40 Terminal boards: poles 12A - 250V Programming connector: Female Jack Stereo d=2.5mm Compatible with all System 44 elements Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. MIFARE technology Means: ISO7816 (Credit card format) Transponder: 13.56MHz MIFARE RFID (ISO type A standard) Compliance with standards R&TTE 1999/5/EC Directive Made of class 1. In compliance with ETSI EN Ver (2006-4) harmonised standards EMC Directive 2004/108/EC. In compliance with the following harmonised standards: - ETSI EN Ver ( ) - ETSI EN Ver ( ) - EN : A1: A2:2007 LVD 2006/95/EEC. In compliance with EN :2006 harmonised standards Auxiliary relay outputs Maximum applicable load (resistive A.C.): 250Vac (cosϕ 1) Maximum applicable load (CC): 30Vdc Maximum applicable load (inductive A.C.): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electric) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency 5(3)A 230V~ cycles/hr. Made in Italy 6 mm Court. 3 2 Court BU B OVERALL DIMENSIONS 441GA30-T DISTURB DISTURB 45 mm A B BUS 12V Made in Italy 6 mm Clima FEM 5(3)A 230V~ ,5 mm 55,5 mm

41 Network system with MIFARE technology Elettricità Evoluta dal 1904 Cod. Description Modules 441GA30-M Internal reader with pocket - MIFARE 3 Domus 100 series 442GA30-M Internal reader with pocket MIFARE 3 Life44 series 44GA30-M V 442GA30-M Made in Italy 5(3)A 230V~ BUS 6 mm B A CONTACT BOARD DESCRIPTION Terminal Colour Description A Green Pole A Line RS-485 A B Made in Italy 6 mm B Green Pole B Line RS Black Negative Supply (Common Inputs) BUS 5(3)A 230V~ + Black Positive Supply 1 Green Input (e.g. Room status detection) 12V Green Input (e.g. Courtesy Light) 3 e 4 Green Output (e.g. Courtesy Light) Green Common for Terminals 6, 7 and 8 6 Green Output (e.g. Electric lock) 7 Green Output (e.g. Bell) 8 Green Output (e.g. Guest In ) 41 A B Made in Italy 6 mm

42 Network system with MIFARE technology 42 Termostat 441AR52-M 442AR52-M The thermostat is used for detecting environment temperature and management of the thermoregulation of a hotel room or other premises in general. The thermostat is capable of communicating with the room control unit, and it is driven by the latter through the monitoring central station, hence allowing remote control of the temperature. This device is provided with two live analogue auxiliary inputs (+5Vdc) for detecting resistive values (room/window status and water temperature) and with four dry contact relay outputs. Electrical features With DC power supply Supply voltage: +12Vdc ±25% Stand-by absorption (@ +12Vdc): 50mA Maximum absorption (@ +12Vdc): 150mA With AC power supply Supply voltage: 12Vac ±30% Allowed supply frequency: 50 60Hz Stand-by absorption (@ 12Vac): 75mArms DESCRIPTION OF DISPLAY OVERTEMPERATURE: overtemperature control enabled ANTIFREEZE: antifreeze control enabled BUS: system connected to Bus KEY LOCK ENABLED Maximum absorption (@ 12Vac): 200mArms Climatic conditions Reference relative temperature and humidity: 25 C RH 65% Operating temperature range: 0 C +40 C Maximum relative humidity: +35 C Maximum altitude: 2000m a.s.l. Mechanical features Container: 3 S44 modules (67.5 l x 45 h x 55.5 d) mm Max extension from components wire: 6.5 mm (from plate wire) Degree of protection: IP40 Terminal boards: poles 12A - 250V Programming connector: Female stereo jack d=2.5mm Compatible with all System 44 elements Temperature detection Measurement range: from 0 C to 40 C Regulation range: 30 C (from 5 C to 35 C) Reproducibility error: 0.2 C (max) Consistency: 0.3 C (max) Thermostat differential: from 0.2 C to 0.2 C to 2.5 C adjustable Display in C or F Compliance with standards ARMBUS ADDRESS: used only during programming step SUMMER: thermostat in summer mode. If blinking it means the window is open INTERMEDIATE : mild season mode. If blinking it means the window is open WINTER: winter mode. If blinking it means the window is open SAVING MODE: operating time controllerd by external clock IEC/EN : automatic electrical controls for household and similar use (Part 1 - general requirements) IEC EN : automatic electrical controls for household and similar use (Part 2-9 Particular requirements for control devices sensitive to temperature) Auxiliary relay output Maximum applicable load (resistive): 250Vac (cosϕ 1) Maximum applicable load (inductive): 250Vac (cosϕ 0.4) Duration of contact (electric): manoeuvres maximum load) Maximum switching (electrical) frequency: 1200 cycles/hr Duration of contact (mechanical): manoeuvres Maximum switching (mechanical) frequency: cycles/hr. NIGHT SAVING: thermostat in night saving mode FAN COIL: air conditioner enabled (fan symbol). The vertical bar indicates the fancoil speed. OFF REGULATION: thermoregulation disabled manually. Antifreeze and overtemperature functions remain enabled ANTIFREEZE: antifreeze function enabled (valve open and fan speed 1) TEMPERATURE MEASURE- MENT UNIT: C = degrees Celsius F = degrees Fahrenheit E = temperature out of range

Advanced hotel systems

Advanced hotel systems www.ave.it +39 030 24981 Advanced hotel systems sta118-sett08-i AVE Since 1904, the days of my great grandfather, we have been key players in uncountable technological evolutions. However, 2008 definitely

More information

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation R001 Room Control Unit TG650 Summary TG650 Microprocessor Room Control Unit is designed to manage and control hotel room services. The Room Unit automatically manages the electric system validation on

More information

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCR3.2/.. Chipcard reader HOTEL SOLUTION s 6 332 HOTEL SOLUTION Chipcard reader HCR3.2/.. Chipcard reader for hotel room access control Reads access code on chipcard Transfers access code to room controller Built-in optical display of messages

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

HOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW

HOTEL ROOM MANAGEMENT SYSTEM - specifications OVERVIEW OVERVIEW The purpose of this this specification document is to define the main features and guide lines for the Hotel Room Management System, which includes Access Control, Guest Management, & Building

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

Controller board and power supply for vivimat III systems

Controller board and power supply for vivimat III systems Controller board and power supply for vivimat III systems Ref: VIVIMAT-3.0 The controller board and power supply vivimat 3.0, is the central core of the vivimat III home automation system. The vivimat

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Passion for KNX innovation

Passion for KNX innovation Passion for KNX innovation Touch-MyDesign 2 Touch-MyDesign is a KNX switch with capacitive buttons that satisfies the design requirements of any building thanks to its total customization: Everyone can

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS

More information

Hotel System Management The Hotel Smartest Solution

Hotel System Management The Hotel Smartest Solution Hotel System Management The Hotel Smartest Solution Apice Hotel System is a natural evolution of the Building Automation line; it integrates a number of highly technological products, specifically designed

More information

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TX GSM SMS Auto-dial Alarm System. Installation and User Manual TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses

More information

Thermostat with display

Thermostat with display H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

ACR880 GPRS Portable Smart Card Terminal

ACR880 GPRS Portable Smart Card Terminal ACR880 GPRS Portable Smart Card Terminal Technical Specifications Subject to change without prior notice Table of Contents 1.0. Introduction... 3 2.0. Features... 4 3.0. Supported Card Types... 5 3.1.

More information

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1 Public 1 (13) User Manual Access Touch 3.1 Version Date Author Description 1.00 30.09.2011 Pah First version Public 2 (13) 1. Purpose of this user manual... 3 2. Description of Access Touch 3.1... 3 3.

More information

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012 Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012 OPUS A3 Standard Full Landscape OPUS A3 Standard Full Neutral 1 Order Numbers OPUS A3 STANDARD Full Wachendorff Projektor Landscape

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

USB Plus+ RFID Reader Setup Guide

USB Plus+ RFID Reader Setup Guide 875-0042-03 RevA USB Plus+ RFID Reader Setup Guide 1 Government Limited Rights Notice: All documentation and manuals were developed at private expense and no part of it was developed using Government funds.

More information

F454. Web Server. User Manual 05/12-01 PC

F454. Web Server. User Manual 05/12-01 PC F454 Web Server User Manual 05/2-0 PC 2 Web Server Contents Introduction and basic functions 5. Connection modes 6.. Connection to the data network 6..2 Remote connection 6.2 Using the Web Server with

More information

MultiViu Flex 7 Data Sheet

MultiViu Flex 7 Data Sheet Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,

More information

Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.

Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02. +3 # Version Date Author Description 1.00 19.07.2010 Jpo First version 1.01 21.12.2010 Jpo FET output descriptions made clearer 1.02 04.02.2011 Jpo Reset button added 1. Purpose of this user manual...

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution

More information

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply 1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,

More information

Central Monitoring and Control Software for GRMS & Access Control

Central Monitoring and Control Software for GRMS & Access Control Central Monitoring and Control Software for GRMS & Access Control (GRMS) is to provide convenience to the guest, enhance the operator s management control and provide energy savings. GRMS is based on an

More information

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-220 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL For Use in 208 to 240 Volts Single and 3 Phase ATS Systems With 110Volt AC or DC Control Motors and selenoids 4501 NW 27 ave Miami FL 33142

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Read carefully

More information

Transponder reader CÉLIANE TECHNICAL GUIDE

Transponder reader CÉLIANE TECHNICAL GUIDE CÉLIAE TECHICAL GUIDE Description The transponder reader is a device that activates when the appropriate badge is placed in front of it (1-2 cm). The badge is the transponder. The signal generated by placing

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product Information S N O. Portable VIP protection CCTV & Alarm System 2 Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-A

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

MANUAL PC1000R INFO@APART-AUDIO.COM

MANUAL PC1000R INFO@APART-AUDIO.COM MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

NGSS Data Consolidator (DC)

NGSS Data Consolidator (DC) NGSS Data Consolidator (DC) The Data Consolidator (DC) facilitates system configuration, monitors network status, and supervises long-term data storage and remote data transmission. The DC consists of

More information

The house is a machine for living. Le Corbusier, Toward an Architecture, 1923

The house is a machine for living. Le Corbusier, Toward an Architecture, 1923 black Cyan 100% White The house is a machine for living. Le Corbusier, Toward an Architecture, 1923 is a brand we believe in the technology that makes life easier. We build devices that make simpler gestures

More information

Integrated Building Management and Security System. Building Automation & Security. www.coba-group.com

Integrated Building Management and Security System. Building Automation & Security. www.coba-group.com Integrated Building Management and Security System Building Automation & Security www.coba-group.com INTEGRATED BUILDING MANAGEMENT AND SECURITY SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3

More information

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK Security Door Controls 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP

More information

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE Technical Teaching Equipment Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE EDIBON SCADA System Teaching Technique used 4 5 2 Data Acquisition Board Cables and

More information

Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012

Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012 Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012 OPUS A6 STANDARD Basic Landscape OPUS A6 STANDARD Basic Landscape/Portrait 1 Order Numbers OPUS A6 STANDARD Full Wachendorff Projektor

More information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM Flexible, Expandable, Economical. The i-pass system comprises of the i-pass controller built with state of the art technology to provide reader access for up to 16 doors and 32 elevator

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: sec.electronics@siol.net http://www.secelectro.com SEC Electronics

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

IntesisBox KNX - LON

IntesisBox KNX - LON IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,

More information

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users. BIBUS VOP Advice for use: large blocks of flats with switchboard and mixed mainly audio systems Ideal for door phone systems with up to 250 users VOP technology Easy creation of mixed audio and video door

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

GSM COMMUNICATORS CATALOGUE

GSM COMMUNICATORS CATALOGUE COMMUNICATORS CATALOGUE ( ) 870020/B - 07/2007 - Daitem - ATRAL SYSTEM S.A.S. - R.C.S. Grenoble 311 586 382 The services and product data presented in this document may be modified without prior notice

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

Business/Home GSM Alarm System. Installation and User Manual

Business/Home GSM Alarm System. Installation and User Manual Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET: SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the

More information

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments The MSITel module family allows your ground console to be everywhere while balloon experiments run everywhere MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

More information

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM MAKING SMART TOWNS, BUILDING SMART COMMUNITIES WHY PANASONIC? RESIDENTIAL STORAGE BATTERY SYSTEM The next evolution in solar energy solutions. Panasonic

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology: //DATASHEET XS4 Mini Cutting-edge design + Amazing technology: Stylish design is a SALTO trademark and with the XS4 Mini, we raise the bar on this already high standard thanks to the XS4 Mini s small,

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

VTO6xxx. IP door stations. User manual

VTO6xxx. IP door stations. User manual VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor

More information

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: WWW.BRITEQ-LIGHTING.COM TABLE OF CONTENTS STGE COO 48 Preliminary User Guide Official version will follow soon on: WWW.BITEQ-IGHTIG.COM TBE OF COTETS 1. Safety Instruction 2. Technical Specification 3. How To Set The Unit 4. How To Control The

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

Controls for fan coil units and cassettes

Controls for fan coil units and cassettes Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11

More information

FT-1000/GPS-N. System of remote monitoring and control of physical

FT-1000/GPS-N. System of remote monitoring and control of physical FT-1000/GPS-N System of remote monitoring and control of physical Localization of vehicles during transport by sending the values of temperature, RH%, etc.. with relative alarm threshold is exceeded. Send

More information

PK5500 v1.1 Installation Instructions

PK5500 v1.1 Installation Instructions PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Installation manual. Version 1.1. www.videx-security.com

Installation manual. Version 1.1. www.videx-security.com Installation manual Version 1.1 www.videx-security.com 2 Table of Contents MANUAL INTRODUCTION... 4 SYSTEM INTRODUCTION... 4 SYSTEM COMPONENTS... 5 CONTROLS... 6 3.5A 13.8Vdc PSU... 6 CONTROL PCB... 6

More information

Well-Contact Suite Client Software Guidelines and precautions

Well-Contact Suite Client Software Guidelines and precautions 01592 Well-Contact Suite Client Software Guidelines and precautions INDEX SECTION A: Guidelines for the creation of the ETS project 2 Rules to follow for the ETS project 2 Parameters to set on the transponder

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company

USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output Introduction: VE02AL, VE05AL is designed for VGA +Stereo Audio signal over cost effective CAT5 cable to instead of VGA and

More information

CISA esigno Contactless Lock

CISA esigno Contactless Lock CISA esigno Contactless Lock Innovative Security Solution for Hotels & Resorts Seamless Contactless Wireless esigno Contactless lock CISA esigno is the latest addition to our range of security solutions

More information