Series Sump and Sewage Systems
|
|
- Noah Hall
- 7 years ago
- Views:
Transcription
1 Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13
2 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column Type Sump & Sewage Pumps. Built from the highest quality engineered components, these pumps can be supplied as replacement pumps or as part of a new installation. Armstrong systems are available with control panel, level controls, and sump pit cover plate. Sewage Series 0 & 2 Armstrong sump pumps are offered in two designs, engineered to handle a wide range of waste water pumping requirements. 0 Standard Features centerless ground stainless steel shaft Enclosed-type bronze impeller, keyed to shaft Cast iron inlet strainer Flexible coupling Plate-mounted alemite grease fittings Intermediate grease-lubricated bronze guide bearings for pit depths over ft. (1.2m) 2 Standard Features 1¼" (32mm) heavy-duty carbon steel shaft Heavy-duty grease-lubricated bronze guide bearings Enclosed-type bronze impeller Cast iron inlet strainer Flexible coupling Raised thrust bearing mounted in a dirt and moisture resistant housing Plate-mounted alemite grease fittings Intermediate grease-lubricated bronze guide bearings for pit depths over ft. (1.m) Flanged pump column pipe 2 Optional Features Pump conversion for condensate service consisting of water lubricated graphite pump bearings, stainless steel shaft and bronze impeller Water lubricated cutless rubber bearings stainless steel shaft Armstrong sump pump designs address the specific requirements for light-duty or heavyduty commercial applications such as: elevator pits, electrical tunnels, loading docks, drain tiles, laundry facilities, floor drains and condensate returns.
3 Sewage Series 0 Armstrong 0 Series sewage pumping systems for building, municipal and industrial applications provide a top-quality, reliable and long-lasting product. Sewage Series 0 Pumps Armstrong sewage pumps feature a screenless design, capable of handling waste material and sewage up to 2½" (mm) solids. Standard Features 1¼" (32mm) carbon steel shaft Gas-tight construction Raised thrust bearing mounted in a dirt and moisture resistant housing Cast iron 2-vane open-type impeller Floor plate mounted alemite grease fittings Grease-lubricated bronze guide bearings for pit depths over ft. (1.m) Flanged pump and column pipe Optional Features Water-lubricated cutless rubber bearings Water-lubricated graphite bearings stainless steel shaft
4 Series 000 Controls & Accessories Choose Armstrong pumping systems for reliability, efficiency and quality engineered products. Control Panel Armstrong Sump & Sewage systems are available with a variety of starting equipment choices. Features nema 1 control panel enclosure ul 0 or csa approved Main disconnect Thermal and short circuit protection using internal circuit breakers Failure protection with automatic transfer to nonoperating pump (duplex system) Control transformer with fused primary (ul 0) Power-on and pump-run indicating lights Hand-Off-Automatic selector switch Optional Features nema 2, 3,, x or 7 enclosure High level buzzer or " (1mm) bell, indicating light and silence reset push button Overload pilot lights Elapsed time meters Individual disconnect switches Electrical alternation (duplex system) Level Controls Ball and rod type float switch governs the control of pump operation based on sump liquid level. Level controls are mounted on a cast iron pedestal and bolted to sump cover plate. Features Copper ball, brass float rod and stops, float guide pipe and cast iron pedestal Mechanical alternator with emergency start position is supplied with duplex units Optional Features High level alarm devices are mounted on sump cover plate and can be provided in two types: a) nema 1 compression type switch with integral buzzer and alarm contract b) Ball & rod float switch, to be wired to separate alarm panel or alarm bell nema or nema 7 enclosure Bulb-type level controls supplied with mounting plate, electrical connectors, and level control support Cover Plate and Curb Frame Circular or square sump cover plate and curb frame can be supplied with openings for simplex or duplex pump configurations. Cover plate includes 3" (7mm) npt threaded vent and inspection cover. Senses static head pressure between media and bellows in the switch enclosure As liquid level rises, trapped air in compression pipe causes bellows to expand and trips the microswitch activating an external circuit as well as an integral alarm compression high water switch float switch
5 Composite Charts 170 rpm capacity - L/s 1 3 total head - feet E-3 0-1KB E-9 2-1KE E D E-3 2-2D E-3 2-2KE E-1 0-3D E E total head - meters E- 0 -D curve no. pump size max. solid size E-3 0 1A/bh Bilge Water only E D Bilge Water only E-3 2 2D Bilge Water only E-9 2 1KE Bilge Water only E-3 2 2KE Bilge Water only E-1 0 3D 2" (0mm) dia. E- 0 D 2AA/db" (mm) dia. E-71 0 E 2AA/db" (mm) dia. capacity - USgpm capacity - L/s E-0 2-1KE E- 2-2KE rpm total head - feet 9 E-3 0-2D E- 2 2D E-2 0-3D E-72 0-E 7 E- 0 -D curve no. pump size max. solid size E-3 0 2D Bilge Water only E- 2 2D Bilge Water only E-0 2 1KE Bilge Water only E- 2 2KE Bilge Water only total head - meters 3 E-2 0 3D 2 (0mm) dia. E- 0 D 2AA/db (mm) dia. E-72 0 E 2AA/db" (mm) dia capacity - USgpm
6 Series 000 Section & Parts List Series 0 Sump Pump Series 2 Sump Pump Series 0 Sewage Pump item no. description item no. description item no. description 1 Volute 12 Discharge Pipe Screw & Washer 332 Grease Fitting 2 Impeller 1 Cover Plate & Lower Bearing 333 Lock Nut 3 Lower Discharge Elbow 2 Cover Plate Screw 33 Shaft Volute Screw Motor Support 3 Impeller Key Discharge Flange 7 Motor Screw 31 Coupling Key 7 Discharge Flange Gasket 223 Support Screw 33 Pipe Nipple Flange Nut 22 Column Pipe 3 Pipe Coupling 9 Flange Bolt 2 Intermediate Bearing Screw 3 Tube Connector 11 Impeller Nut 22 Intermediate Bearing Nut 3 Elbow 11 Impeller Washer 3 Ball Bearing 37 Lubrication Tube 123 Strainer Intermediate Bearing Assembly 3 Bearing Collar 12 Discharge Pipe 31 Snap Ring 39 Bearing Frame Screw 1 Strainer Screw 321 Oil Seal 1 Coupling 12 Suction Plate 331 Grease Fitting 01 Motor 127 Discharge Elbow 03 Floor Plate
7 Dimensional Data round square round square cover plates - simplex units inches (mm) a sump size b motor frame size inches (mm) cover plates - duplex units inches (mm) pump size inches (mm) e 1½b 2d 2d 1½e 2½e 3d d e 2 () 2 (711) 3 (7) 3 (7) 1N (32) 1N (32) 1O () 1 () N () N () (72) 3 () (2) (2) 1O () 1O () 1N (32) (2) 2O (70) 2O (70) 3 (91) (1) (3) (3) 3O (9) 3O (9) 3N (3) (2) O (121) O (121) 2 (7) (11) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1219) (1372) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1372) 0 (2) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 0 (2) (17) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 72 (129) 7 (191) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 2 () 2 (711) 3 (7) 3 (7) 1N (32) 1N (32) 1O () 1 () N () N () (72) 3 () (2) (2) 1O () 1O () 1N (32) (2) 2O (70) 2O (70) 3 (91) (1) (3) (3) 3O (9) 3O (9) 3N (3) (2) O (121) O (121) 2 (7) (11) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1219) (1372) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) (1372) 0 (2) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 0 (2) (17) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 72 (129) 7 (191) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) series c 13tc 1tc 12tc 1tc 213tc 2tc tc tc 0 H (approx.) 2 & 0 H (approx.) a sump size b 1X (22) 21K () 1K (19) 22 (9) 17K () 22 (9) O (7) K () e 2N (7) 27O (70) 2O (7) ½b 2d 2d 1½e 2-1/2e 3d d e 3 (91) (1) 2 (1) 2 (1) 2N (7) 2N (7) 2O (70) 0 (0) 1O () 1O () 2 (7) (11) (2) (2) 1O () 1O () 1N (32) (2) 2O (70) 2O (70) (1219) (1372) 9 (229) 9 (229) O (121) O (121) N () 7 (17) O (1 O (1 12 (1372) 0 (2) () () O (1) O (1) N (133) (3) O (171) O (171) 1 0 (2) (17) () () O (1) O (1) N (133) (3) O (171) O (171) 1 72 (129) 7 (191) 12 () 12 () 7O (197) 7O (197) 7N (1) () O (222) O (222) 1 3 (91) (1) (3) (3) 3O (9) 3O (9) 3N (3) (2) O (121) O (121) 2 (7) (11) 9 (229) 9 (229) O (121) O (121) N () 7 (17) O (1) O (1) 11 (1219) (1372) 11 (279) 11 (279) O (171) O (171) N (9) 9 (229) 7O (197) 7O (197) 12 (1372) 0 (2) () () O (1) O (1) N (133) (3) O (171) O (171) 1 0 (2) (17) () () O (1) O (1) N (133) (3) O (171) O (171) 1 72 (129) 7 (191) 13 (3) 13 (3) O (222) O (222) N (2) 11 (279) 9O (2) 9O (2) 1 sump depth in feet (m) no. of intermediate bearings 0 to 3. (0 to 1.07) (0) 0 0 to. (0 to 1.) (2+0) 0 to (1.2 to 1.9) (0) 1 to (1. to 2.) (2+0) 1. to (2 to 2.) (0) 2 9 to 12 (2.7 to 3.7) (2+0) 2 (0) 3 pump size 0 1½b 0 2d 2 2d 2 1½e 2 2½e 0 3d 0 d 0 e ½ (1) 7 (17) 11V (23) N (20) 11N (2) 9 (229) Y (27) 11Y (2) O f g pump discharge K (11) (127) 2N (7) 3 (7) 3 (7) (9) 7N (1) 7N (1) Screwed 1½" npt Screwed 2" npt Screwed 2" npt Screwed 1½" npt Screwed 2½" npt Screwed 3" npt Flanged " 1#asa Flanged " 1#asa k note 1: High water alarm furnished only when specified. note 2: Sump depth determined by actual job requirements. note 3: Series 0 and 2 have Vertical Discharge. Series 0 has Elbow Discharge. *Dimensions f, g, & h apply to both Simplex and Duplex units. Denotes minus dimension as centerline of pump is left of cover plate center.
8 Typical Specifications Furnish and install, as illustrated on the plans & specifications, an Armstrong Series 000 simplex or duplex pumping system. pumps - 0 Sump Pump shall be Model: 0 vertical centrifugal, flexible coupled for sump service. Each pump shall provide USgpm at feet of tdh at a speed of rpm. Pump length will be suitable for a pit depth of feet. The pump casing shall be cast iron with a bronze enclosed impeller complete with a cast iron inlet strainer. Pump shaft shall be one piece centerless ground stainless steel. Pump shaft shall be guided by grease lubricated upper ball bearing and intermediate bronze sleeve type column bearing(s). Pump column assembly is constructed of threaded steel schedule 0 pipe. Intermediate bearing(s) are greased by a lubrication system consisting of ¼" (.3mm) copper grease lines and Alemite fittings terminating at floor plate. pumps - 2 Sump Pump shall be Model: 2 vertical centrifugal, flexible coupled for sump service. Each pump shall provide USgpm at feet of tdh at a speed of rpm. Pump length will be suitable for a pit depth of feet. The pump casing shall be cast iron with a bronze enclosed impeller complete with a cast iron inlet strainer. Pump shaft shall be one piece 1¼" (32 mm) diameter carbon steel or turned and polished stainless steel. Pump Shaft shall be guided by grease lubricated upper ball bearing and intermediate bronze sleeve type column bearing(s). Flanged steel column assembly is complete with register fit guide bearing housings to ensure proper alignment. The upper bearing(s) will be ball type, heavy duty grease lubricated, mounted in a raised bearing housing to prevent moisture, and dust and dirt contact. Intermediate and lower bearing(s) are greased by a lubrication system consisting of ¼" (.3 mm) copper grease lines and Alemite fitting(s) terminating at floor plate. pumps - 0 Sewage Pump shall be Model: 0 vertical centrifugal, flexible coupled for sewage service. Each pump shall provide USgpm at feet of tdh at a speed of rpm. Pump length will be suitable for a pit depth of feet. Pump shall be capable of passing solids sizes of 2" (1 mm) and 2½" ( mm). The pump casing shall be cast iron complete with a non-clog cast iron 2 vane open type impeller. Pump shaft shall be one piece 1¼" (32 mm) diameter carbon steel or turned and polished stainless steel. Pump shaft shall be guided by grease lubricated upper ball bearing(s) and intermediate bronze sleeve type column bearing(s). Flanged steel column assembly is complete with register fit guide bearing housings to ensure proper alignment. Packing seal provides GAS TIGHT construction. The upper bearing(s) will be a ball type, heavy duty grease lubricated, mounted in a raised bearing housing to prevent moisture, and dust and dirt contact. Intermediate and lower bearing(s) are greased by a lubrication system consisting of ¼" (.3 mm) copper grease lines and Alemite fitting(s) terminating at floor plate. motor Pump motor shall be a vertical type round body design. Motor horsepower shall be not less than hp, volts, phase, 0 Hz. Motor Enclosure shall be odp, tefc or Explosion Proof. optional construction: 2 & 0 pumps Cutless Rubber Lower & Intermediate Sleeve Bearings: Cutless Rubber Lower & Intermediate Sleeve Bearings are provided to handle abrasive liquids without scoring or damaging the shaft. A separate fresh water line connection is provided for connection to outside source with solenoid valve (supplied by others) to be energized when pump motor operates. Pumps are complete with stainless steel shaft for longer bearing life. Graphite Lower & Intermediate Bearings: Graphalloy intermediate and lower bearings are provided to handle liquids above 0 f ( c). Pump is complete with stainless steel shaft for longer bearing life. For condensate applications, pump is complete with bronze impeller. pump control Pump control shall be ball & rod mechanical float switch. Unit consists of copper ball, brass rod & stops. Float switch is mounted on a cast iron pedestal and bolted to sump cover plate. Duplex unit with mechanical alternating float switch complete with high level emergency start position turning on both pumps in case of high liquid level. high level alarm System shall include compression type high water alarm complete with alarm buzzer and additional contact for remote signaling. Alarm shall be housed in a nema 1 enclosure and mounted on sump cover plate. control panel Armstrong series 000 systems shall include nema 1 Control Panel with the following Standard Features: ul 0 or csa approved Main Disconnect Thermal and Short Circuit Protection using Internal Circuit Breakers Failure Protection with Automatic Transfer to Non-Operating Pump (Duplex System) Control Transformer with Fused Primary (ul 0 only) Power-On and Pump-Run Indicating Light Hand-Off-Automatic Selector Switch optional control features nema 2, 3,, x or 7 Enclosure High Level Buzzer or " (1 mm) Bell, Indicating Light and Silence Reset Push Button Overload Pilot Lights Elapsed Time Meters Individual Disconnect Switches cover plate and curb frame Circular or square sump cover plate and curb frame shall be supplied with openings for simplex and duplex pump configurations. Cover plate includes 3" (7 mm) npt threaded vent and inspection cover. S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: F: Armstrong Pumps Inc. 93 East Avenue North Tonawanda, New York U.S.A., 11-9 T: F: Armstrong Integrated Limited Wenlock Way Manchester United Kingdom, M12 JL T: + (0) 1 1 F: + (0) 1 1 S. A. Armstrong Limited 13 For Armstrong locations worldwide, please visit
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationMODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationSJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
More informationVERTICAL TURBINE AND PROPELLER PUMPS
VERTICAL TURBINE AND PROPELLER PUMPS INTRODUCTION Vertical Turbine and Propeller Pumps Model 7000 Series Turbine Pump Model 800 Series Axial Flow Propeller Pump Model 800 Series Mixed Flow Propeller Pump
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationJOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationFire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
More informationVertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
More informationItem No. Name of Part Item No. Name of Part Item No. Name of Part
www.cranepumps.com Parts for Fig. 4001 Bulletin Item No. Name of Part Item No. Name of Part Item No. Name of Part 1 2 6 9 11 *13 *16 17 *18 19 24 *29 32 37 40 46 Casing Impeller Pump Shaft Suction Cover
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationPumps SELECTION OF A PUMP
Pumps SELECTION OF A PUMP A water system needs to move the water produced from the source to its customers. In almost all cases in Minnesota, the source is at a lower elevation than the user so the water
More information4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
More informationBOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.
SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION
More informationFAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
More informationWilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
More information5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationNumber Wheeler P/N Description Set Rex P/N Notes 1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8)
1 603500 Base 1 J001 2 603501 Support, Right 1 J002 3 603502 Support, Left 1 J003 4 600328 Nut (M8) 4 5 600130 Spring Washer (8mm) 4 6 600344 Roll Pin (M6x30) 4 7 600129 Socket Hd Cap Screw (M8x25) 4 8
More informationNumber Wheeler P/N Description Set Rex P/N Notes
1 604041 Base 1 4041 2 604042 Base Cover 1 4042 3 608849 Washer (M5) 2 4 600124 Spring Washer (M5) 2 5 600329 Rd Hd Machine Screw (M5x8) 2 6 604047 Strainer 1 4047 7 600204 Rd Hd Machine Screw (M6x10)
More informationVertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
More informationMultistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
More informationService Instructions Manual 2110.802B Chicago Pump type VOS and VPM non-clog pumps
Service Instructions Manual 2110.802B Chicago Pump type VOS and VPM non-clog pumps Frames: LL4, OL4, LM4, OM4, OMC6, LMC6, OS6, LS6, LSC8, OS8, LS8, OSC10, OLC10, LLC10 and OLC12 UPON RECEIPT OF PUMP EQUIPMENT:
More informationModel 413 AURORA. 410 Series SINGLE STAGE SPLIT CASE PUMPS WWW.AURORAPUMP.COM
Model Model AURORA Series SINGLE SAGE SPLI CASE PUMPS WWW.AURORAPUMP.COM SINGLE SAGE SPLI CASE PUMPS AURORA Series Single Stage Split Case Pumps Capacities to 00 GPM (0 m /hr) Heads to Ft. (0 m) emperatures
More informationSERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
More informationAxial and Mixed Flow Pumps for Large Volume Pumping
Vertical Industrial and Process Axial and Mixed Flow for Large Volume Pumping Encased (Can ) Water and Process Liquid Vertical Turbine for Water Supply from Drilled Wells Vertical close coupled single
More informationDry Pit Solids Handling Pumps
Dry Pit Solids Handling Pumps A Time-Tested Leader Chicago Pump Dry Pit Solids Handling Pumps have an established reputation of efficiency, long life and reliable operation First in: Quality 3Reliability
More informationThe conditions below apply to the curves shown on the following pages.
GENERAL INFORMATION STAINLESS STEEL, SILVERLINE, EVERGREEN & GOLDLINE SERIES PERFORMANCE CURVE CONDITIONS The conditions below apply to the curves shown on the following pages. a. The Performance curves
More informationSRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List
SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List For MG, WG, WGL, and Grinder Pumps for Effluent & Sewage CAUTION! Read these safety warnings first before
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More informationSeries 1510 Centrifugal Pumps Technical Bulletin. Bulletin B-207G Bell & Gossett
Bulletin B-7G Bell & Gossett Series 1 Centrifugal Pumps Technical Bulletin For hydronic heating and cooling systems, industrial, pressure boosting and general pumping applications High efficiency, low
More informationKESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850 Product advantages Automatic float switch as water
More informationHorizontal Split Case Fire Pumpset Diesel Engine Driven
SERIES Horizontal Split Case Fire Pumpset Diesel Engine Driven Selected Models INTRODUCTION Lubi offers LHCD series state-of-the-art fire pumpset with diesel engine driven, horizontal split case pump.
More informationCDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100
CONTENTS Page - CONTENTS 100 - SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 70 202 PERFORMANCE CHART 90 203 PERFORMANCE CHART 120 204 PERFORMANCE CHART 200 205 - CONSTRUCTIONS 300 SECTIONAL
More informationModel 763 AURORA. 750/760 Series APCO-PM CONSTANT PRESSURE BOOSTER SYSTEMS WWW.AURORAPUMP.COM
Model 763 AURORA 750/760 Series APCO-PM AURORA-PC CONSTANT PRESSURE BOOSTER SYSTEMS WWW.AURORAPUMP.COM 2 AURORA 750/760 Series Constant Pressure Booster Systems Introduction Constant Pressure Pumping Ever
More informationBERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
More informationHorizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz
SERIES Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz Selected Models INTRODUCTION Lubi offers LHCE series state-of-the-art fire pumpset with electric motor driven, horizontal split case
More informationWhat Does A Sump Pump Do?
Wastewater Products Automatic submersible cast iron sump pump Ideal for high volume water removal applications Heavy duty cast iron construction For years of service and reliability Clog-resistant design
More informationTrash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001
Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001 Specifically designed pumps for heavy duty applications Handles solids with eas and simple to open and clean Standard roll
More informationGoulds Water Technology
APPLICATIONS Specifically designed for: Homes Farms Cottages Booster service SPECIFICATIONS Pump: Pipe connections: 1¼" NPT suction, 1" NPT discharge, 1" NPT drive (pressure) Pressure switch: AS4 preset
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationBERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationConstantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
More informationMDT5N25 & MTD5N40 SERVICE PARTS
MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts
More informationPump and Valve Components and Maintenance
Pump and Valve Components and Maintenance Outline: 1. Split case and End Suction pumps, industry in the 21 st century, cost of ownership, and performance tips 2. Split case Pumps features, maintenance,
More informationThe Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
More informationWATER pressure. Issue 3 / 2014. Clear water pumps for domestic and commercial applications
Issue 3 / 214 WATER pressure PUMPS AND washdown transfer pumps Clear water pumps for domestic and commercial applications Email: enquiries@dlmwallace.co.nz Web: www.dlmwallace.co.nz Auckland: Maurice Road,
More informationBOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
More informationGE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping
GE Oil & Gas Texsteam * Pumps: precise chemical injection pumping 2 With a wide range of capacities and operating pressures, GE s versatile Texsteam pumps can handle challenging chemical pumping requirements
More informationBSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
More informationNumber Wheeler P/N Description Set Rex P/N Notes
1 607051 Base 1 A050 2 607052 Motor Cover 1 A052 3 600778 Socket Hd Cap Screw (M8x60) 2 4 607053 Scrap Receiver 1 A053 5 607054 Tank Upper Cover 1 A054 6 607055 Oil Pot 1 A055 7 607056 Strainer 1 A056
More informationSIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: sigmahra@sigmahra.cz
More informationSIGMA GROUP a. s. Divize průmyslová čerpadla
SIGMA GROUP a. s. Divize průmyslová čerpadla SIGMA GROUP a. s. INDUSTRIAL PUMP DIVISION Jana Sigmunda 79, 783 50 LUTÍN SEWAGE PUMPS NFPH, NFVH, NFJH, NFRH, NFPV, NFVV, NFJV, NFRV, NFPW NFVW Tel.: +420
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationSunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
More informationTECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS
TECHNICAL BROCHURE BAQUABII * Available up to 1 GPM systems Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS FEATURES The AB2 variable speed pump controller and complete booster package kits, provide
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationFULL PRODUCT GUIDE. performance quality service trust
FULL PRODUCT GUIDE performance quality service trust Vertical Turbine, Lineshaft & Submersible Pumps 6 & Larger Delivering Vertical Turbine Pump Reliability, Quality and Service Since 1969 Pump Type 6-30
More informationINSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
More informationIF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
More informationMÁQUINAS AGRÍCOLAS JACTO S.A. EDITION
AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: export@jacto.com.br
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More information3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide
", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,
More informationTown House 11265 Center Highway North Huntingdon, PA 15642
APPENDIX C SPECIFICATIONS FOR THE CONSTRUCTION OF BUILDING LATERAL SANITARY SEWERS DECEMBER 2004, INCLUDING AMENDMENTS ADOPTED ON FEBRUARY 6, 2008 AND APRIL 2, 2008; EFFECTIVE ON MAY 1, 2008 Town House
More information2" & 3" Poly Wet Seal Pump Instruction Manual
Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction
More informationD Youville College July 31, 2008 New Academic Building Cannon Design Project No. 002935.00
SECTION 22 6119 - COMPRESSED-AIR EQUIPMENT FOR LABORATORY AND HEALTHCARE PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged, oilless scroll air compressors. 1.2 DEFINITIONS A. Actual Air: Air
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationGROENEVELD AUTOMATIC GREASING SYSTEMS
GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991
More information- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationMaxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME
TM Maxi-Stamper 200 to 1,000 Tons STAMPING OUT DOWNTIME Standard Features Steel Fabricated Construction Drive Capacity Rated 1/2 Above Bottom of Stroke Self-Diagnostic Solid State Controller Moveable Operator
More informationBell & Gossett Parts List DHP-650-PL. Replacement Parts for Hoffman Series VBF & Hoffman Series HBF. Boiler Feed Units
Bell & Gossett Parts List DHP-650-PL Replacement Parts for Hoffman Series VBF & Hoffman Series HBF Boiler Feed Units SERIES VBF & HBF Index How to use this Parts List...Page 3 30 VBF (Part number 161024
More informationAFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationInnovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves
A Tradition of Excellence With the development of the first rubber seated butterfly valve more than 70 years ago, the Henry Pratt Company became a trusted name in the flow control industry, setting the
More information300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
More informationDTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
More informationModel: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering
Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety
More informationPower Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
More informationALIGNMENT. Pump and Driver Alignment
ALIGNMENT Pump and Driver Alignment Alignment Subject: Pump and Driver Alignment In the pump business alignment means that the centerline of the pump is aligned with the centerline of the driver. Although
More informationOwner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE
Owner s Manual Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE WARNING!! Installation & Operating Instructions Self-Priming Centrifugal Pump DO NOT
More informationBERMAD Fire Protection
Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around
More informationPipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More informationINDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED
INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING
More informationPump Division MNR MND. Absorber Recirculation Pumps. Bulletin PS-10-32 (E)
MNR MND Absorber Recirculation Pumps Bulletin PS-10-32 (E) Pump Supplier To The World Flowserve is the driving force in the global industrial pump marketplace. No other pump company in the world has the
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
More informationSUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014
SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014 ASSEMBLY and OPERATING INSTRUCTIONS Drain Water From Basements, Boats, Wells, Shafts, Containers and More! Diagrams within this manual may not be drawn
More informationIndex 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationREGULATORS 175/153 Series
175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed
More informationINSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS PARTS LIST
12501 Telecom Drive, Tampa Florida 33637 INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS PARTS LIST 90/4.5.1 Rev.1 CONSTANTEMP LOW PRESSURE STEAM-WATER HEATERS Models E-1500L, E-1520L, E-300L, E-320L,
More informationSUPER-TITAN. Split-case pumps with power, performance and reliability for a world of applications
SUPER-TITAN Split-case pumps with power, performance and reliability for a world of applications The Prestige. The Performance. SUPER-TITAN PUMPS Features The TKL Super-Titan pump makes a significant contribution
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationLOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
More information