Fire Protection. Global Fire Suppression Solutions & Services. Safer.Smarter.Tyco.
|
|
- Britney Marshall
- 7 years ago
- Views:
Transcription
1 Fire Protection Global Fire Suppression Solutions & Services Safer.Smarter.Tyco.
2 Tyco has designed and developed a wide range of internationally approved solutions for Life Safety & Asset Integrity protection are a single source supplier in the provision of life safety and asset integrity solutions worldwide. We are the industry leader with a track record for providing long term sustainable fire suppression systems in some of the harshest environments imaginable. During the past forty years, we have protected virtually every type of Business / Process Critical Area ensuring your life safety and asset integrity systems are fit for purpose. Where we work Offshore Installations Petrochemical Plants Marine Chemical Plants Military Vessels Industrial Military Sites Power Plants Industrial Complexes Renewable Energy Sites We have achieved this recognition by ensuring that the working life of all types of fire suppression systems that we provide has been safeguarded against replacement from potential future changes in Health & Safety and Environmental Legislation. We have dedicated design engineers and project management teams working exclusively in preferred supplier partnerships around the world. Our continued success is reflected by the large number of global partnerships we maintain with some of the world s top 100 companies within the industrial, commercial, marine, oil & gas and power generation market sectors. Fire protection systems we provide Gaseous Watermist Waterspray Foam Portable equipment Areas we protect Tank storage Galley Helideck Services we provide Workshop support Offshore servicing Integrated maintenance
3 Individual customer requirements are met through tailored service agreements Gaseous Fire Suppression INERGEN INERGEN has been extensively used throughout the world as a preferred gaseous fire suppression agent for over 16 years and remains the longest surviving Halon replacement on the market to date. INERGEN is a mixture of three inert, naturally occurring gases: 52% nitrogen, 40% argon, 8% carbon dioxide. The discharge mixture of INERGEN makes it unique as no other inert gas has the unique ability to rapidly extinguish a fire yet at the same time provide a safe environment for any person within the occupied area by actually decreasing cardiac distress and maintaining arterial blood oxygenation and mental performance in low oxygen levels. As INERGEN is derived from gases present in the earth s atmosphere, it exhibits a no ozone depleting potential, nor does it contribute to global warming. Unlike some chemical gaseous fire suppression agents, INERGEN does not, and could never create a reaction with a fire to create extremely harmful toxic or corrosive by-products. Novec1230 Novec1230 is the next generation of chemical fire suppressant in place of FM200. Novec 1230 systems are designed to extinguish fires involving flammable liquids, gases and electrical equipment. As a clean agent, it leaves no residue, it is ideally suited to protect applications where high margins of safety and long term sustainability are considered important. The Global Warming Potential (GWP) of Novec 1230 is 1 (relative to CO 2 ). Novec 1230 is supplied in lightweight cylinders with a small footprint that requires minimal storage space. It has a boiling point of 49 C and therefore exists as a liquid at room temperature. Super-pressurised with nitrogen to 25bar it rapidly extinguishes a fire through a combination of heat absorption (its main action) and some chemical interference with the flame. Novec 1230 vaporises easily upon discharge, making it an effective total flooding agent for a variety of hazards. CO 2 Systems Carbon dioxide is the original clean agent that is traditionally used for total flooding applications to suppress fires in unmanned areas involving deep seated Class A fire risks. CO 2 is the original clean agent that suppresses fire without leaving behind an agent to damage sensitive equipment. Tyco can provide high pressure cylinder systems and low pressure tank systems for the protection of engine rooms, pump rooms and machinery spaces. It is essential that all personnel be trained on CO 2 systems to ensure their safety. They must be warned not to enter the hazard area during discharge or until the area is cleared. Watermist Fire Fighting System Watermist is a versatile and highly efficient fire-fighting medium. What differentiates Watermist from traditional water based systems is its reduced droplet size. When a droplet of water vaporises, it expands by some 1,600 times. Because heat absorption is a function of surface area and not volume, smaller droplets mean more surface area and therefore faster heat absorption. Watermist has the unique ability to deliver water as a fine atomised mist. This mist is quickly converted to steam that smothers the fire and prevents further oxygen from reaching it. At the same time, the evaporation creates a significant cooling effect of combustion gases and blocks the transfer of radiant heat. In this way, Watermist combines the fire suppression properties of both conventional water-based deluge or sprinkler systems and gaseous fire suppression systems. Branded as ProtectoMist Low Pressure Water Mist and MicroDrop High Pressure Water Mist, Tyco have designed and developed both systems to deliver droplet momentum to the seat of the fire.
4 Waterspray Fire Fighting System Tyco introduced, pioneered and developed the world s first medium and high velocity waterspray systems under the brand names of ProtectoSpray and MulsiFyre. Both systems are designed to extinguish oil fires and fires involving flammable liquids and gases by the use of water only. ProtectoSpray Medium Velocity This system is ideal for the protection of indoor process areas involved in the production, storage and loading of highly inflammable and flammable liquids and gases. Medium Velocity waterspray nozzles can also be used with low expansion foam for small storage tank bund protection, to suppress hazardous chemical vapours that may occur as a result of storage tank rupture. MulsiFyre High Velocity Waterspray This system is extensively used throughout industry to protect a wide variety of plant equipment and hazardous materials involving oils with a flash point above 66 C. Typical applications include boiler feed pumps, diesel engines, hydraulic oil systems and steel mills. The MulsiFyre system applies water in the form of a conical spray consisting of droplets of water travelling at high velocity. These droplets bombard the surface of the oil to form a mixture of oil and water. This mixture significantly cools the fire reducing the rate of liquid vaporisation. While the water droplets are passing through the flame zone, some of the water is formed into steam that dilutes the air feeding the fire and creates a smothering effect to extinguish the fire. Foam Fire Fighting System Depending on the type of fire risk and working environment involved, Tyco can provide a wide range of foam systems designed to the latest British Standard and NFPA approvals including: Low expansion system High expansion system Foam enhanced sprinkler system Hot foam system Our commitment to the development of best practice foam system design ensures the most rapid, fire knockdown using the minimum amount of water. This in turn ensures that the amount of hazardous fire effluent is significantly reduced and that the subsequent cost of legislative firewater run off containment is also significantly reduced. Each type of foam concentrate has various features and benefits, applications and limitations. The right choice means bringing together considerations of the hazard, the fuels involved, proportioning and discharge devices used, codes and standards, maintainability and associated costs. Tyco offer a full range of high quality fire fighting foam of both synthetic and protein base. Our Platinum Fire Fighting Foam is tested & approved in accordance with EN1568 Part 3 and is fully compatible with all dry chemical powders and can be used in powder/foam twin agent systems in any proportions. Tyco also offer a foam testing service to ensure that your foam is fully compliant with legislation and meets your needs. Portable Equipment In the field of fire, safety and lifesaving equipment, there can be no substitute for quality and performance. Tyco hold accredited agencies with the majority of principle manufacturers in the fire and safety field. We offer products to the highest technical specification, recognisable in the industry as leading in their field. Our product inventory contains over 1,000 products including: Breathing apparatus Extinguishers Deluge sprinklers Fire clothing Fire detectors Fire hydrants/couplings Fire pumps Foam and water throwing equipment Gas detection GRP containers Hose reels & hose reel cabinets
5 Area Protection Tank Storage Protection Developed as the first line of defence against fire in floating roof oil storage tanks, Nimbus operates automatically on fire detection and discharges FFFP foam to the affected segment of the rimseal. Ideal for new installations and environmentally friendly replacement for existing halon systems. The detection and discharge system uses pressurised nitrogen routed through firetrace detection tubing and triggered via a pilot operated valve connected to the main flow port. The pilot line pressure is maintained at 16 bar from the propellant cylinder. A pressure drop causes the nitrogen valve to trip and pressurise the water storage tank effecting discharge at a set rate through the discharge pipework. The in-line foam inductor induces film forming foam at a 6% ratio. Detection tube ruptures when exposed to fire. Water/FFFP discharges for 30 second duration. The resulting foam solution flows through the distribution pipework to the nozzles where it is discharged as an expanded foam solution onto the affected area. Galley Fire Fighting System A galley fire can be highly dangerous. It can quickly spread and turn a galley into a blazing inferno. The Ansul R102 system uses a specially formulated aqueous solution of organic salts designed for fast knockdown and suppression of grease related fires. Agent storage life expectancy is twelve years. Helideck Fire Fighting System Tyco can provide a wide range of fire suppression agents and equipment to prevent, contain and extinguish a fire. Systems and equipment suitable for the protection of the helideck area include: Dry chemical and twin agent skids High, medium and low expansion foams Foam generators Foam monitors c/w localised foam tanks and self-inducting nozzles Hand portable and wheeled extinguishers Self-contained working pressure vessel system Diff pop-up nozzle system Offshore Servicing and Integrated Maintenance Integrated Maintenance Service provides life cycle maintenance for the majority of fixed and portable fire fighting equipment. This ensures that this life saving equipment is in the best possible operating condition at all times meeting all statutory and regulatory requirements. Tyco s extremely competent and experienced technicians service the equipment offshore and are supported by a 24 hour onshore workshop and technical support. In addition we track and manage the maintenance record via our integrated maintenance database. This can operate alongside or independently from the clients Maintenance Management System. The service can operate as a fully managed fixed priced contract or an adhoc basis. Fully Managed Service The benefits of a fully managed system are as detailed below: Implementation of Tyco maintenance routines Tyco provide unique tags for all loose equipment Database records, maintenance history and scheduled work plans. Spares management - provision of spares per maintennace visit Monthly reports on the status of safety equipment highlighting any areas of non-conformance Tyco hold and manage a buffer stock of equipment to ensure that the client will always have a full range of safety critical equipment. Expansion of Service Tyco can also extend the level of service to cover any scope within the oil, gas and energy division giving Tyco a capability that is truly unique to the oil, gas and energy industry. Dedicated design engineers and project management teams work in partnership to provide fit for purpose solutions
6 Global Strength. Local Expertise. At your service. Web: United Kingdom Aberdeen Tel: +44 (0) Dudley Tel: +44 (0) Manchester Tel: +44 (0) Middle East Dubai Tel: +971 (0) Kuwait Tel: Leverage our capabilities: Fire Protection Fire Detection HVAC Audio Communications Fiscal Metering Detection & Control Wellhead Process Control Deluge Verification De-scaling Interface Engineering Confined Space Management Training Fire & Safety Product Head Office Manchester Tel: +44 (0) Safer.Smarter.Tyco.
Safer.Smarter.Tyco. Watermist fire protection Technology you can trust
Safer.Smarter.Tyco. Watermist fire protection Technology you can trust / 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment
More informationFire Extinguishers Water Extinguishers
Water Extinguishers Water extinguishers are suitable for Class A fires caused by combustion of solid materials such as wood, paper, straw, textiles and coal etc. Water additive extinguishers use an environmentally
More informationTechnologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230
Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec
More informationHSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008
HSE information sheet Fire and explosion hazards in offshore gas turbines Offshore Information Sheet No. 10/2008 Contents Introduction.. 2 Background of gas turbine incidents in the UK offshore sector...2
More informationAlarm and Detection/Suppression
Alarm and Detection/Suppression Fire Safety American Fire Technologies To provide special hazard services world wide to the industrial market through the integration of components and services Clean Agent
More informationEACH CLASS of fire A, B, C, or D has a different source. Some
Classes of Fires and Types of Extinguishers EACH CLASS of fire A, B, C, or D has a different source. Some principles apply to putting out all fires. However, certain procedures and products are used only
More informationFIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT
FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT 1 1. Elements of Fire: The process combustion of fire may be regarded as a chemical triangle in its three side consisting of fuel, heat and oxygen. The control
More informationVehicle Fire Suppression Systems EMAIL COPY ONLY
PORTABLE FIRE EQUIPMENT FIRE PROTECTION SYSTEMS FIRE SYSTEM INSTALLATIONS FIRE SYSTEM SERVICING COMPLIANCE FIRE SAFETY TRAINING MAJOR PROJECTS Vehicle fire suppression systems Vehicle Fire Suppression
More informationBRANCH SOLUTION. Fire protection for wind turbines. Safe for certain
BRANCH SOLUTION Fire protection for wind turbines Safe for certain RISKING A FIRE IS RISKING YOUR INVESTM Over the last few years, the generation of electricity from wind energy has become a major technology
More informationTotal Solutions Provider CAPABILITY PROFILE. www.tycofireuae.com QATAR UNITED ARAB EMIRATES OMAN
Total Solutions Provider CAPABILITY PROFILE www.tycofireuae.com QATAR UNITED ARAB EMIRATES OMAN INDEX Company Profile Mission Statement Nature of Business Manpower Details Locations Service & Maintenance
More informationTotal Solutions Providers for Fire & Security Systems
Total Solutions Providers for Fire & Security Systems Tyco Fire & Security UAE is a joint venture between Suwaidi Engineering Group and Tyco Fire & Integrated Solutions. Established in 1994, we now employ
More informationEXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES
More information- Save lives and reduce material damage
- Save lives and reduce material damage Small droplets reduce heat to a minimum Ultra Fog s high pressure water fog sprinkler system is based on water being sprayed through special nozzles at high pressure.
More informationINERGEN - EXTINGUISHING SYSTEMS
INERGEN - EXTINGUISHING SYSTEMS INERGEN : THE CLEAN SOLUTION. INERGEN extinguishes without leaving any residues, with 100% environmental neutrality to avoid harming nature. As digitalization increases,
More informationAerosol Fire Suppression. Your Choice for Special Hazard Fire Protection
Aerosol Fire Suppression Your Choice for Special Hazard Fire Protection Traditional Special Hazard Fire Protection Centers Around Two Technologies Water deluge and chemical agent fixed systems protect
More informationGAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)
GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS Argotec Liquid Argon Gas Extinguishing Technology (LAR) INNOVATION modern technologie snuffed out cold Argotec liquid argon gas ex tinguishing
More informationVehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems
Vehicle Fire Protection An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems 002792 Off-road vehicles do have fires Statistics show that off-road vehicles burn with alarming frequency. These
More informationHow intelligent must an extinguishing solution be to keep fire virtual?
How intelligent must an extinguishing solution be to keep fire virtual? Intelligent means: fire protection from Siemens. Sinorix intelligent extinguishing solutions. Answers for infrastructure. Sinorix
More informationPORTABLE FIRE FIRE SOLUTIONS 1. Portable Fire Equipment Solutions EMAIL COPY ONLY
PORTABLE FIRE FIRE SOLUTIONS 1 Portable Fire Equipment Solutions 2 PORTABLE FIRE SOLUTIONS We do more than fight fires, we help prevent them Our business is to mind your business A major fire, with its
More informationFactory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
More information- Save lives and reduce material damage
- Save lives and reduce material damage Ultra Fog specialises in high pressure sprinklers for fire extinction using water fog, both at sea and on land. Our base is in Gothenburg, which is where we carry
More informationEthanol Vehicle and Infrastructure Codes and Standards Citations
Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and
More informationFor Data Center and Control Room Applications
For Data Center and Control Room Applications Nearly zero wetting No costly clean up or equipment replacement Sustainable design Quick system recharge, minimal downtime No need for assurance of tight room
More informationRS-44 (R424A) : Q & A
RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,
More informationGuidance for Those Who Use and Store Gas Cylinders
King s Gate Tel 6320 www.safety.ncl.ac.uk Safety Office February 2012 Guidance for Those Who Use and Store Gas Cylinders Version 3 Newcastle University 2012 This guide is designed to help staff manage
More informationCompressed Gas Cylinder Program
Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope
More informationOne united company. Advancing fire protection.
One united company. Advancing fire protection. We are Kidde Fire Systems. Kidde Fire Systems products save people and property from the dangers of fire. Our broad product offering and design expertise
More informationmelbourne//australia data center specifications internet + intellectual property + intelligence tel: +61 2 9948 8888 fax: +61 2 9948 1111
internet + intellectual property + intelligence We thank you for the opportunity to work with you regarding your colocation needs in Melbourne,. We can colocate standard rack-mountable servers or other
More informationECHM Recommendations for Safety in multiplace medical hyperbaric chambers
ECHM Recommendations for Safety in multiplace medical hyperbaric chambers Coordination and Correspondence : D. MATHIEU, Service d'urgence Respiratoire, de Réanimation Médicale et de Médecine hyperbare
More informationGUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS
GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS 1.0 PURPOSE 1.1 To provide an overview of fire extinguisher use
More informationControlling fire and explosion risks in the workplace
Controlling fire and explosion risks in the workplace A brief guide to the Dangerous Substances and Explosive Atmospheres Regulations Introduction to DSEAR This leaflet provides a brief introduction to
More informationCompressed Gas Cylinder Safety
Compressed Gas Cylinder Safety I. Background. Due to the nature of gas cylinders, special storage and handling precautions are necessary. The hazards associated with compressed gases include oxygen displacement,
More informationPANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281
PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281 PanCanal Building Albrook, Panama City Republic of Panama Tel: (507) 501-5355 jortega@segumar.com To: Ship-owners/Operators, Company Security
More informationLiberty Mutual Insurance RISK ENGINEERING PROCEDURE. REP 07 Incident Planning For external use
Liberty Mutual Insurance RISK ENGINEERING PROCEDURE REP 07 Incident Planning For external use Risk Engineering Procedure Incident Planning CONTENTS Page PURPOSE... 3 BACKGROUND... 4 INCIDENT PLANNING PREPARATION...
More informationTake care with oxygen Fire and explosion hazards in the use of oxygen
Fire and explosion hazards in the use of oxygen This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. Hazards from
More informationFire Protection Options for Data Centres
Fire Protection Options for Data Centres Mark L. Robin, PhD DuPont Chemicals & Fluoroproducts mark.l.robin@usa.dupont.com Introduction Modern data centres are characterized by spaces filled with ever-increasing
More informationCOMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.
Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute
More informationMATERIAL SAFETY DATA SHEET
DOT ID No: UN 2187 MATERIAL SAFETY DATA SHEET DOT Hazard Class: 2.2 Emergency No.: +971-6-5336481 Page No. : 1/5 DOT Shipping Label : Non Flammable Gas Date last updated: 22/09/2009 Revision no: 00 1.
More informationNYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY
NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY Presented by: James Goerl Metro Protection Systems, Inc. jgoerl@metroprotectionsystems.com Agenda Introduction & Learning Objectives History
More informationMATERIAL SAFETY DATA SHEET Product Code: 10033
MATERIAL SAFETY DATA SHEET Product Code: 10033 Product Description: Signal Horn & Refilling Canister in Blister Pack 1. IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY: Product Name: Signal Horn & Refilling
More informationDuPont ISCEON MO89 refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More informationModel F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description
Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed
More informationFor Data Center and Control Room Applications
For Data Center and Control Room Applications Nearly zero wetting No costly clean up or equipment replacement Sustainable design Quick system recharge, minimal downtime No need for assurance of tight room
More informationEXTINGUISHER. The purpose of this module is to sensitize firefighters on the subject of extinguishers.
EXTINGUISHER INTRODUCTION Fire extinguishers are essential fire suppression tools that firefighters us in the initial stage of a fire and against this background, it is important to be knowledgeable of
More informationCONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
More informationALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
More informationsingapore//singapore data center specifications tel: +61 2 9948 8888 fax: +61 2 9948 1111 internet + intellectual property + intelligence
internet + intellectual property + intelligence We thank you for the opportunity to work with you regarding your colocation needs in Singapore. We can colocate standard rack-mountable servers or other
More informationWatermist fire suppression systems for commercial low hazard occupancies
Watermist fire suppression systems for commercial low hazard occupancies Watermist fire protection systems are fire suppression systems that have emerged as an alternative fire safety solution for specific
More information1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Types : ASHRAE Refrigerant number designation: R-507
This SDS adheres to the standards and regulatory requirements of the European Community and may not meet the regulatory requirements of other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND
More informationPeasouper Operator s Manual
Peasouper Operator s Manual Contact Information Le Maitre Special Effects, Inc. Canada 1960 Blue Heron Drive, London, ON. N6H 5L9 Phone Direct: (519) 659.7972 Phone Toll Free Direct: (800) 388.0617 Fax:
More informationOntario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
More informationMOTOR FUEL DISPENSING SAFETY
STRATEGIC OUTCOMES PRACTICE TECHNICAL ADVISORY BULLETIN January 2010 MOTOR FUEL DISPENSING SAFETY Fire! Not an alarm anyone wants to hear, especially not when the fire is burning at a major fuel source.
More informationFire detection in kitchens
Fire detection in kitchens Protection of people, business continuity and reputation Large cooking vessels, frying pans, and deep frying vats present a very serious fire hazard in commercial kitchens. This
More informationEMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the
More informationhttp://www.proffire.com
http:// PROFFIRE est une société spécialisée dans la lutte contre le feu en zone à risques ATEX. Son bureau d études et son organisation lui permettent de réaliser des projets clé en main : conception,
More informationCOMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink
COMBUSTION In order to operate a heat engine we need a hot source together with a cold sink Occasionally these occur together in nature eg:- geothermal sites or solar powered engines, but usually the heat
More informationRisk Engineering Guideline
www.hdi.global HDI Risk Consulting Risk Engineering Guideline Impairment of fire protection systems Basic protection systems should not be impaired without adequate replace compensation with provisions.
More informationThis SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries.
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More informationFIRE PROTECTION. FOR COMPUTER ROOMS By Mark L. Robin CLEAN AGENT. FS-World.com. 8 ire & Safety Magazine
S-World.com CLEAN AGENT IRE PROTECTION OR COMPUTER ROOMS By Mark L. Robin Mark L. Robin, Ph.D., is Technical Services Consultant for Specialty luorochemicals with DuPont luoroproducts and has over 20 years
More informationFIRE EXTINGUISHER TRAINING
FIRE EXTINGUISHER TRAINING Fire safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. Three things must be present at the same time to produce fire:
More informationTECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland
TECHNICAL NOTES Literature Review on Hybrid Fire Suppression Systems Peter Raia Michael J. Gollner University of Maryland Fire Protection Research Foundation May 2014 The Fire Protection Research Foundation
More informationMATERIAL SAFETY DATA SHEET - Air-Compressed
1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME: CHEMICAL NAME: CHEMICAL FAMILY: SYNONYMS: CHEMICAL FORMULA: USE: NAME AND ADDRESS: Air, compressed Air Nonflammable gas Medical Air, Breathing Air, Compressed
More informationDuPont SUVA 123 Refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More informationFIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES
FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES Fire and Life-Safety Group (FLS) FLS has organized the following information to act as a guideline/checklist for any inspection, maintenance,
More informationFire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers
A Health and Safety Guideline for Your Workplace Introduction Fire extinguishers are designed to put out or control small fires. A small fire, if not checked immediately, will soon spread out of control.
More informationBRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.
BRANCH SOLUTION Automatic fire extinguishing systems for paint spraying plants Safe for certain. ISK IDENTIFYING With the extreme high degree of automation in painting technology, the risk of fire has
More informationR407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C
GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant
More informationone source, endless capabilities COMPANY PROFILE
COMPANY PROFILE INDEX Introduction Nature of Business Prequalification Facts Contracting Capabilities Service & Maintenance Quality, Health, Safety and Environment Training Page 2 of 14 INTRODUCTION Established
More informationENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS
ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered
More informationThis leaflet provides information on
This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. HSE8(rev2) Hazards from oxygen Oxygen gas in cylinders is used
More informationWINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D
1. PRODUCT AND COMPANY IDENTIFICATION Product information Product name : WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA- D Recommended use : Hard Surface Cleaner Manufacturer, importer, supplier : S.C. Johnson
More information: DuPont SUVA 410A Refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More information1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING
ANSUL ANSUL INCORPORATED MARINETTE, WI 54143-2542 INERGEN MATERIAL SAFETY DATA SHEET CONFORMS TO DIRECTIVE 2001/58/EC 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING 1.1.
More informationHot water supply, distribution and use
Guidance Leaflet Reducing use Hot supply, distribution and use All businesses use hot in some way, whether for domestic use, in the manufacturing process or for ancillary activities. As there are considerable
More informationSteam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation
Steam Generator Boilers Compact Steam Boilers Rapid Start-Up Safe in Operation AB&CO TT BOILERS The boiler maker AB&CO TT BOILERS LTD. have since the middle sixties produced industrial boilers and heaters
More informationThis SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries.
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More informationCIBSE Guide M: Maintenance engineering and management Statutory compliance legislation and guidance
CIBSE Guide M: Maintenance engineering and management compliance legislation and guidance Types of System/Plant Action required Frequency by Type of Fire and Smoke Fire extinguishers Discharge (not CO
More informationFire Protection of Data Centres
Fire Protection of Data Centres With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Need a fire fighting system that: Allows
More information: DuPont SUVA 134aUV Leakdetect
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More informationHELI-DECKS & HELI-PORTS
1 HELI-DECKS & HELI-PORTS GENERAL FOAM INFORMATION DESCRIPTION Helicopters provide a level of convenience that is probably unequaled by other forms of transport. While helicopters can land in the middle
More informationInspection and Testing of Water-Based Systems
Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level III Content Outline The candidate for NICET certification at Level III in the Inspection and Testing of Water-Based
More informationFull scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009
Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 By Carsten Palle, VID Fire-Fill, www.vid.eu Presented at ISTSS
More informationStatic Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?
A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered
More informationGTM PORTABLE GAS TRANSPORT. a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight
GTM PORTABLE GAS TRANSPORT a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight Transporting high pressure gases with current applications
More informationWhat is Dry Ice? Dry Ice Company Safety Rules: DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT
DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT What is Dry Ice? Dry Ice is frozen carbon dioxide. Unlike most solids, it does not melt into a liquid, but instead changes directly into a gas. This process
More informationCertain specific properties of compressed gases make them highly useful in various research activities.
GAS CYLINDER SAFETY Introduction Certain specific properties of compressed gases make them highly useful in various research activities. These gases, however, can be dangerous if not handled in an appropriate
More informationStatic Spark Ignites Flammable Liquid during Portable Tank Filling Operation
Static Spark Ignites Flammable Liquid during Portable Tank Filling Operation No. 2008-02-I-IA (September 2008) Key Lessons for Safe Handling and Storage of Flammables Ensure that equipment, such as fill
More informationAll You Ever Wanted to Know About Fire Extinguishers...
All You Ever Wanted to Know About Fire Extinguishers... There are basically four different types or classes of fire extinguishers, each of which extinguishes specific types of fire. Newer fire extinguishers
More informationContinuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
More informationWINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- D
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : WINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- Use of the : Hard Surface Cleaner Substance/Mixture Company : S.C. Johnson & Son,
More informationFire Suppression Systems for Your Home
ABN 64 127 735 433 PO Box 395 Mundaring. 6073. Phone/fax 9295 6263. Mob 0439 971 213 office@waterinstallations.com 18 Wandeara Cres, Mundaring. 6073. Fire Suppression Systems for Your Home Hills residents
More information"USING FIRE EXTINGUISHERS SAFELY"
MAJOR PROGRAM POINTS "USING FIRE EXTINGUISHERS SAFELY" Part of the "GENERAL SAFETY SERIES" Quality Safety and Health Products, for Today...and Tomorrow Outline of Major Points Covered in the "Using Fire
More informationMission-critical fire protection HI-FOG for data centres
Mission-critical fire protection HI-FOG for data centres Modern fire protection for a data-driven world We make a strong case that HI-FOG is the best available fire protection for mission-critical data
More informationCO 2. fire extinguishing systems
fire extinguishing systems Extinguishing technique is a colourless, odourless and electrical non-conductive gas. In systems the is mixed with a special identifiable odour. The extinguishing effect of is
More informationFire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing
Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing Notice to Shipowners, Ship Operators, Managers, Masters, Owners Representatives and Recognised
More information: Fairy Professional Original Washing Up Liquid 5L
PROFESSIONAL Fairy Professional Original Washing Up Liquid 5L Date of issue: 17/11/2011 Revision date: Version: 1.0 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1.
More informationPortable Fire Extinguisher Presentation
Slide 1 Fire Extinguisher Training A requirement of all Clemson University Employees as mandated by OSHA: Portable fire extinguishers. - 1910.157 Welcome to the Clemson University Online Fire Extinguisher
More information: DuPont SUVA 407C Refrigerant
This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries. 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE
More informationCertificate of Conformity Certificate num. Registration date Version Valid until
CSIRO Verification Services Highett, Victoria, Australia +61 (0)3 9252 6000 http://www.activfire.gov.au/ Page 1 of 5 Issued by Product designation Thorn Security, FM-200, engineered gaseous 'total flooding',
More informationMaterial Safety Data Sheet
1 IDENTIFICATION OF THE SUBSTANCE AND COMPANY a) SUBSTANCE: Natural Gas b) COMPANY: Bord Gáis Éireann PO Box 51 Gasworks Road Cork Telephone: (021) 453 4000 Emergency Telephone: 1850 20 50 50 2 COMPOSITION/INFORMATION
More information