1 Anechoic chamber from ETS-Lindgren Moscow Peterburg Lukasz Wilk 1

2 Production Plant Eura, FI 2

3 Overall Assessment An anechoic chamber is a construction project that can take several months to complete. It is usually a significant investment with a projected life cycle of typically > 10 years. In order to make the right choice a potential buyer should assess the supplier on the following issues : Project capability Technical performance Commercial conditions Financial risk

4 Project Capability Supplier s Reference list Supplier s Mechanical engineering/design capability Supplier s Manufacturing capability Supplier s Installation capability Supplier s RF engineering/design capability 3 rd party evidence of compliance

5 Price What is included? What is excluded? Commercial Terms and Conditions Warranty Delivery schedule Sub contract How much of the scope is sub contracted

6 Financial Risk Ability to complete the project Size of company vs project value Credit limit Assets Debt Ability to support after sales service Spare parts Maintenance

7 Buying from a low bidder Price is low Why? Hidden costs? Risk is higher? Lower quality Unable to service/maintenance = lost revenue Smaller company Long term issues Unable to service/maintenance = lost revenue Delivery issues Delays = extra costs/lost revenue Extra cost involved in managing the project

8 Michael Faraday ( ) Faraday was a British chemist and physicist who contributed significantly to the study of electromagnetism and electrochemistry. 8

9 9 Faraday s Law demo

10 Magnetic Field Lines Around a Wire, Magnetic Field agnet.fsu.ed u/education/t utorials/java/ fieldlines/ind ex.html Current Wire 10

11 11 EM Wave

12 WAVES Sinusoidal waves of various frequencies; the bottom waves have higher frequencies than those above. The horizontal axis represents time. 12

13 13 Basics wavelength = Speed of light / Frequency Wavelength : Speed of light : Frequency: metres metres per second (108 Million Km/h) Hz

14 Faraday cage A Faraday cage is an enclosure formed by conducting material, or by a mesh of such material. Such an enclosure blocks out external static electrical fields. Faraday cages are named after physicist Michael Faraday, who built one in

15 Faraday cage Electronic components or systems that require an environment free of electromagnetic interference may be done a so-called screen room. These screen rooms are completely enclosed by sheet metal. The metal layers are connected to earth ground to dissipate any electric currents generated from the external electromagnetic fields 15

16 Main Shield Technologies Modular S81 Enclosure (Sandwitch) Modular S101 Enclosure (Pan-type) 16

17 Modular S81 Panels Construction The Series 81 Shielded Enclosure consists of shielded modular panel sections that are assembled with a clamping system into a self-supporting room structure. Sheets of 28-gauge galvanized steel are laminated to a 3/4-inch, high-density particle and/or plywood board core. Each panel section provides excellent stability to airborne moisture-induced warping and structure strength that lend to its rugged structural design. Series 81 panels are joined together with an extruded hat and flat and cove clamping system to provide uniform and consistent pressure contact against the shielded panel mating surfaces. These structural clamping sections are zinc-plated to resist corrosion and are joined with self-taping zinc-plated fasteners spaced four inches on center to ensure a secure shield. The corners of the shielded room are secured with precision-machined trihedral end cap sections. To maintain electrical isolation, a 6-mil dielectric vapor barrier and 1/8" dielectric underlayment are placed beneath the shielded floor panels. Counter-sunk floor screws in the clamping system ensure a smooth floor surface. Attractive vinyl floor tiles are applied with adhesives over the exposed steel surface as a durable wearing surface. In addition, the Series 81 enclosure can be converted into a ferrite-lined and/or conventional absorber-lined anechoic chamber. This feature makes it a truly flexible shielding solution. 17

18 Modular S101 Panels Description The Series 101 rooms can be dismantled and reinstalled, enlarged or modified due to the panel system. Only the gasket and the fasteners have to be replaced. No special tools nor welding are necessary during the installation. No maintenance is necessary after installation. The modular structure allows for very flexible adaptation to the customer's needs and requirements. Both the size and shape of the room can be designed to meet the individual needs of the customer. As only the system (distance of holes and increments in the outer dimensions) and the panel joint are standardized, Series 101 is not limited to the use of only a few standard size panels. However, the automated manufacturing technology utilizes the advantages of high quantity production of standardized panels. The same manufacturing technology can be applied to different materials such as hot galvanized steel and aluminum. The requirements can be realized by using same machinery, thus enabling cost-effective solutions and a competitive price-quality-ratio. The panel system provides a reliable and high performance shielding, as the panels are jointed with special gasket. However, at the same time the number of fasteners can be minimized, which also shortens the assembly time. The Series 101 panels can be bolted from inside or from outside, depending on the purpose and requirements. The shielded room can also include a combination of flat sides inside and outside. When installing the enclosure from inside (flat side outside), the enclosure can be assembled in close proximity(e.g. without a supporting structure as close as 5 cm) of existing walls of the parent building and the panel bendings (flanges) can be used for installing inner lining or absorber rails when appropriate. When installing the enclosure from outside (flat side inside), the hanging from the support structure does not penetrate the shielding and the inside is flat. This is required in partial discharge / high voltage testing halls as well as when either ferrites or absorbers are glued directly onto the walls and ceiling. Please note that the space required for the installation work is about 800 mm all around, also above the roof. As the Series 101 corner joint is identical to the intermediate joint no additional supports or special constructions are needed. The corners have equally reliable attenuation as the rest of the enclosure. Electromagnetic interference has no chance: no way in or no way out, as the case may be. This is just an example epitomizing that the Series 101 enclosure forms a carefully designed entity with painstaking attention to detail. 18

19 Shielding Effectiveness typical SE values pending on door tpye / RF-components S81 Enclosure S101 Enclosure (RFD-100 door) 19

20 Field Frequency Pan (S101) Sandwich (S81) Magnetic 1 khz 45 db 20 db Magnetic 10 khz 85 db 56 db Magnetic 100 khz 105 db 100 db Magnetic 1 MHz 120 db 110 db Magnetic 10 MHz 125 db 110 db Electric 100 MHz 125 db 110 db Electric 1 GHz 125 db 110 db Plane Wave 10 GHz 125 db 100 db Plane Wave 18 GHz 125 db 80 db Plane Wave 40 GHz 125 db - Note : Performances stated must be measured without absorber

21 Basic Swing Doors S501 Door for S81 Enclosure RFD Door for S101 Enclosure 21

22 RF-Shielded Double Door 22

23 RF-Shielded Sliding Door 23

24 Anechoic Chamber Swing Door 24

25 Anechoic Chamber Sliding Door 25

26 Anechoic Chamber Sliding Door 26

27 Large Shielded Sliding Door 27

28 Shielded Enclosure Accessories 28

29 Shielded Enclosure Accessories Filter out of factory Stevenage, UK 29

30 The Absorber Family 1 Ferrite Tile. Magnetic Losses Preferred technology for Low frequencies (up to 2GHz), it has low profile (7mm max). It cannot be used for high frequencies

31 The Absorber Family 2 Microwave Pyramidal absorber. Electric Losses Preferred technology for High frequencies It can be used for low frequencies if size (length) is increased

32 The Absorber Family 3 Hybrid Absorber. Electric and Magnetic Losses Preferred technology for EMC Applications. foam has to have special low carbon content for good matching with ferrite tile at the bottom. At High frequencies its performance is not as good as MW pyramid of equal size.

33

34 Anechoic Chambers An anechoic chamber is a shielded room designed to attenuate waves. An RF anechoic chamber is designed to suppress the reflected electromagnetic waves, from the internal surfaces. 34

35 Anechoic Chambers In a well-designed anechoic chamber, the equipment under test receive RF signals from the signal source, not reflected from another part of the chamber. This ensures the integrity of the testing being conducted. Furthermore, the shielding of the chamber limits interference from equipment located outside of the chamber. 35

36 Anechoic Chambers They are lined with an absorbent material, such as carbonimpregnated foam shaped into pyramids. The pyramidal shape acts to resist and dissipate the electromagnetic waves. Testing is done in anechoic chambers to analyze the properties of antennas and other electronics that are susceptible to radio or microwave interference. 36

37 Anechoic Chambers Anechoic chambers range from small compartments to chambers as large as aircraft hangars. The size of an anechoic chamber depends on the size of the objects to be tested and the frequency range of the radio or microwave signals used. 37

38 Anechoic Chambers Radio frequency interference (RFI) is the unwanted reception of radio signals and can be problematic to the other electronic equipment onboard aircraft and other vehicles. Radio frequency interference sources include lightning, electrical equipment, fluorescent lighting, cell phones, and transmitting equipment from radio stations. RFI testing helps determine which frequencies affect particular electronic systems and provide clues to reducing the risks to communication devices or developing measures to counter the interference. 38

39 Turn-key Solution 39

40 Antennas

41 RF numerical modeling Mechanical design Fabrication Measurement

42

43 Low frequency immunity horns

44 EMC / OTA Positioners

45 EMC Field Sensors

46 Shielded Doors, CCTV Cameras and Filters

47 Products made from various sources are never perfect in terms of compliance Don t like it, choose ETS-Lindgren. Designed, made, installed with related test equipment: ETS-Lindgren!!! 47 / 91

48 Service Design & construction Project management On site project management / supervision Full installation / shield test Maintenance 48

49 Summary Chamber Capabilities Standard MIL STD 461 CISPR25 IEC CISPR NSA CISPR svswr Distance 1m 1m 3m* 3m 5m 10m 3m 5m 10m Chamber Test T T R R R R R R R Start Frequency 80MHz 70MHz 80MHz 30MHz 30MHz 30MHz 1GHz 1GHz 1GHz Stop Frequency 40GHz 2.5GHz 6GHz 1GHz 1GHz 1GHz 6GHz 6GHz 6GHz Pre- Compliant Compact T T R T T T T T T MIL STD 461 R T T T T T T T T CISPR 25 R R T T T T T T T Compliant 3 meter R R R R T T R T T 5 meter R R R R R T R R T 10 meter R R R R R R R R R

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output Evaluation of Anechoic Chambers For EMC Measurements Using A CNE Overview Anechoic chambers are used for EMC testing primarily for radiated emissions (RE) and radiated immunity (RI) in the frequency range

More information

MRI RF SHIELDING DESIGN

MRI RF SHIELDING DESIGN MRI RF SHIELDING DESIGN Nelco s MRI RF Shielding is specifically designed for the MRI industry. Our engineers have developed a shielded enclosure made entirely of nonmagnetic materials that is unsurpassed

More information

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility Absorber Technologies and Its Impact on Anechoic / Semi Anechoic Chambers Peggy Girard November 2012 Discussion Points Brief

More information

Radio Frequency Interference (RFI) Shielding Principles

Radio Frequency Interference (RFI) Shielding Principles Radio Frequency Interference (RFI) Shielding Principles 1.0 Introduction The purpose of this document is to provide Krieger Specialty Products clients and personnel information pertaining to shielding

More information

EMC Standards: Standards of good EMC engineering

EMC Standards: Standards of good EMC engineering Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards

More information

EMI/RFI Shielded Cable Tray

EMI/RFI Shielded Cable Tray EMI/RFI Cable Tray Chalfant began supplying industry cable tray in 1948 and designed and developed the first RF Tray for NS in 196 when it became imperative to protect instrument and control cabling from

More information

FDTD Analysis of Site Free Space VSWR in Test Site Used for Disturbance Measurement above 1 GHz

FDTD Analysis of Site Free Space VSWR in Test Site Used for Disturbance Measurement above 1 GHz 九 州 工 業 大 学 学 術 機 関 リポジトリ Title FDTD analysis of site free space VS disturbance measurement above 1 GHz Author(s) Kuwabara N; Midori M; Kawabata M Issue Date 9-8 URL http://hdl.handle.net/8/368 9 IEEE.

More information

Since the middle of the 20 th century, the variety of applications

Since the middle of the 20 th century, the variety of applications Since the middle of the 0 th century, the variety of applications requiring electromagnetic absorbers has been increasing rapidly. Therefore, new materials had to be developed, each targeting a specific

More information

For emission and immunity testing according to IEC 61000-4-20

For emission and immunity testing according to IEC 61000-4-20 EMC GTEM 500 Gtem Cell For emission and immunity testing according to IEC 61000-4-20 Theory of operation GTEM-cells (Giga-hertz Transversal Electro-Magnetic cells) are waveguide structures intended for

More information

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic Test Room ID: R21F Description: SEMI ANECHOIC SHIELDED TEST ENCLOSURE Primary Testing Uses: FCC, CE Mark Dimensions: 9.75m x 6.10m x 5.49m (32ft. x 20ft. x 18ft.) [see Figure 3 below] Construction: Galvanized

More information

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module Engineering Test Report No. 37802-02 Rev. A Measurement of RF Emissions from a Final Coat Electronics Corrosion Module For : Canadian Auto Preservation, Inc. 390 Bradwick Drive Concord, Ontario CANADA

More information

for Communication Systems Protection EMI CD-ROM INCLUDED

for Communication Systems Protection EMI CD-ROM INCLUDED Krešimir Malarić EMI Protection for Communication Systems CD-ROM INCLUDED Contents Preface xiii CHAPTER 1 Communications Systems 1 1.1 Components of Communications Systems 1 1.2 Transmitter Systems 2 1.2.1

More information

EH-20 20m antenna. By VE3RGW

EH-20 20m antenna. By VE3RGW EH-20 20m antenna By VE3RGW Equivalent circuit of EH-20 (prototype 2A) antenna system. Upper cylinder Lower cylinder Ground Counter pose Phasing coil Impedance transformer and tune circuit Tune coil Feed

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

Ferroxcube. For more information on Product Status Definitions, see page 3. 2008 Sep 01 275 CBW625

Ferroxcube. For more information on Product Status Definitions, see page 3. 2008 Sep 01 275 CBW625 CBW625 For more information on Product Status Definitions, see page 3. 2008 Sep 01 275 INTRODUCTION Ferrites are used not only in the known consumer and professional electronics applications, but also

More information

Knürr Smaract. Knürr Smaract. CompactRack

Knürr Smaract. Knürr Smaract. CompactRack CompactRack Features Ample space for components and cabling provided in an efficient, compact design. The innovative frame concept with triangular extrusions ensures low weight while maintaining high stability.

More information

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz Test & Measurement Data Sheet 02.00 R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz R&S R-Line Compact Test Chamber At a glance The R-Line

More information

Embedded Parts Introduction - Anchors

Embedded Parts Introduction - Anchors In the plant construction or process plants such as chemical, petrochemical, gas or power plants various disciplines are brought into contact and built on each other. Civil, mechanical, electro technical

More information

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology Antennas for EMC Testing Zhong Chen ETS-Lindgren 1301 Arrow Point Drive Cedar Park, TX 78613 Zhong.Chen@ets-lindgren.com Outline EMC Terms and Definitions Typical EMC Antennas Calibration of EMC Antennas

More information

Microwave Absorbers. Absorber for Microwave and Millimeter Wave Test Chambers S SYSTEMS C CHAMBERS A ANTENNAS SW SOFTWARE

Microwave Absorbers. Absorber for Microwave and Millimeter Wave Test Chambers S SYSTEMS C CHAMBERS A ANTENNAS SW SOFTWARE Microwave Absorbers Absorber for Microwave and Millimeter Wave Test Chambers S SYSTEMS A ANTENNAS C CHAMBERS SW SOFTWARE History With a worldwide reputation for high quality and innovative absorber techniques,

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

Investigation of the Calibration Procedure from CISPR 25, Annex B, for use with Vehicle Component Testing.

Investigation of the Calibration Procedure from CISPR 25, Annex B, for use with Vehicle Component Testing. Investigation of the Calibration Procedure from CISPR 25, Annex B, for use with Vehicle Component Testing. Dennis D Swanson, EMC Engineer TijV Product Service 1775 Old Highway 8 New Brighton MN 551-1891

More information

EMC Engineering Guidelines For Automation Systems PS 4 PS 416 04/97 AWB 27-1287-GB

EMC Engineering Guidelines For Automation Systems PS 4 PS 416 04/97 AWB 27-1287-GB EMC Engineering Guidelines For Automation Systems PS 4 PS 416 1st edition 04/97 Moeller GmbH, Bonn Author: Werner Albrecht Editors: Klaus Krüger, Thomas Kracht Translator: Chris Baker, Terence Osborn Contents

More information

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness Shielding Effectiveness Test Method Harbour s LL, SB, and SS Coaxial Cables Designs for Improved Shielding Effectiveness Harbour Industries 4744 Shelburne Road Shelburne Vermont 05482 USA 802-985-3311

More information

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point Overview To optimize the overall performance of a WLAN in an outdoor deployment it is important to understand how to maximize coverage

More information

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT INCH-POUND MIL-STD-220C 14 May 2009 SUPERSEDING MIL-STD-220B 24 January 2000 DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD OF INSERTION LOSS MEASUREMENT AMSC N/A FSC EMCS FOREWORD 1. This standard

More information

November 2013. 3-terminal Filters. For signal line. MEM series. * Dimensions Code JIS[EIA]

November 2013. 3-terminal Filters. For signal line. MEM series. * Dimensions Code JIS[EIA] E M C C o m p o n e n t s November 0 -terminal Filters For signal line MEM series MEM0S MEM0SC MEM0V MEM0F MEM608P 0[0805 inch]* 0[0805 inch] 0[0805 inch] 0[0805 inch] 608[060 inch] * Dimensions Code JIS[EIA]

More information

Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique :

Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique : Simulation électromagnétique 3D et câblage, exemples dans l'automobile et aéronautique : CST, Christophe Morin 1 www.cst.com Agenda - Présentation CST - Simulation câblage dans modèle 3D - Exemples automobile

More information

40 Years of experience in EMC testing

40 Years of experience in EMC testing 40 Years of experience in EMC testing Your reference laboratory for tests of generation, propagation and reception of electromagnetic energy in civil, military and industrial applications. CESI has been

More information

LOW LOSS CABLE PAG. 1

LOW LOSS CABLE PAG. 1 LOW LOSS CABLE PAG. 1 INTRODUCTION Following many requests we received regarding the need for low-loss custom cable assemblies, we have set up a special production of high performance coaxial cable assemblies

More information

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Final inspections are completed by site visit only. Access to fenced yards shall be planned. ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,

More information

Subject: Glenair MIL-PRF 24758 Conduit Surface Transfer Impedance Test

Subject: Glenair MIL-PRF 24758 Conduit Surface Transfer Impedance Test Lothar O. Hoeft, Ph.D. Consultant, Electromagnetic Effects 5012 San Pedro Ct., NE Albuquerque, New Mexico 87109-2515 Phone: (505)-889-9705 E-mail: bud.hoeft@ieee.org 1 February 24, 2006 Subject: Glenair

More information

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information Commissioning instructions CI/FPD580/A EN StackFlowMaster FPD580 TORBAR probe Stack gas metering systems Measurement made easy Introduction This publication provides commissioning instructions for the

More information

Owner's Manual & Assembly Instructions

Owner's Manual & Assembly Instructions Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

Screened cable and data cable segregation

Screened cable and data cable segregation December 2007 Screened cable and data cable segregation Can an armoured power cable be considered a screened cable and how does this relate to power and data cable segregation? The short answer is yes;

More information

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB

SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB

More information

A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System

A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System 538 Progress In Electromagnetics Research Symposium 2006, Cambridge, USA, March 26-29 A Study of RF Absorber for Anechoic Chambers Used in the Frequency Range for Power Line Communication System K. Shimada

More information

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK EMC Technology Product Section Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise TDK Shonai Corporation Satoru Saito Reduce Emission Noise from Cables Even if an electronic

More information

Generic - Hearing Loop - (AFILS) U.S. System Specification

Generic - Hearing Loop - (AFILS) U.S. System Specification This document is a generic specification for any Hearing Loop (Audio Frequency Induction Loop System). For the remainder of the document, we will refer to using the term Hearing Loop rather than Audio

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

Cellular Wireless Antennas

Cellular Wireless Antennas Cellular Wireless Antennas A Technical Brief GarrettCom Inc., November 2010 Overview The Cellular Wireless Antenna Technical brief is provided to assist with the design and deployment of the DX940 Cellular

More information

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R) This document outlines the specifications for the Cisco Aironet 2.4-GHz MIMO Wall-Mounted Omnidirectional Antenna (AIR-ANT2440NV-R)

More information

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical

More information

An extended EMC study of an electrical powertrain for transportation systems

An extended EMC study of an electrical powertrain for transportation systems European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 12) Santiago de Compostela

More information

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com

Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC Measurements by Henry W. Ott Henry Ott Consultants www.hottconsultants.com Workbench EMC measurements are simple, inexpensive precompliance tests that a product designer can perform early

More information

Omni Antenna vs. Directional Antenna

Omni Antenna vs. Directional Antenna Omni Antenna vs. Directional Antenna Document ID: 82068 Contents Introduction Prerequisites Requirements Components Used Conventions Basic Definitions and Antenna Concepts Indoor Effects Omni Antenna Pros

More information

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4 MoTeC USA GPS Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4 MoTeC USA GPS Copyright Motec Systems USA 2008 The information in this document is subject to change without notice. While

More information

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps

More information

Espotel Test Laboratory Services. November 20, 2014

Espotel Test Laboratory Services. November 20, 2014 Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN

More information

Effectiveness of Shielding Methods Using a Pockel s Cell Driver

Effectiveness of Shielding Methods Using a Pockel s Cell Driver Effectiveness of Shielding Methods Using a Pockel s Cell Driver Tristan Dennen (UCLA) September 19, 2007 Abstract Pockel s Cell Drivers produce a 2.5 kv pulse used for simulating ANITA events. The noise

More information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force

More information

SATELLITE MASTER ANTENNA TELEVISION SYSTEM

SATELLITE MASTER ANTENNA TELEVISION SYSTEM SATELLITE MASTER ANTENNA TELEVISION SYSTEM The Contractor shall supply, install, test, commission, guarantee and maintain a Modern Satellite Master Antenna Television (SMATV) system for the distribution

More information

TECHICAL SPECIFICATION IP65 EMI EMC Gaskets

TECHICAL SPECIFICATION IP65 EMI EMC Gaskets Pag. 1/5 TECHICAL SPECIFICATION IP65 EMI EMC Gaskets Description Market requirements permit us to offer different gaskets that cover the double function of watertight seals and electromagnetic interference

More information

Guide to Safety Edge Systems

Guide to Safety Edge Systems Guide to Safety Edge Systems Tel: 0845 054 5070 asosafety@egduk.com Guide to Safety Edges All new automatic gate & door systems installed in the UK should comply to BS-EN13241-1 & EN-138491-1 harmonised

More information

THE ACOUSTICS OF ROOMS

THE ACOUSTICS OF ROOMS Killam 1 THE ACOUSTICS OF ROOMS Josiah Killam PHYS 193: The Physics of Music Prof. Steven Errede University of Illinois at Urbana-Champaign Killam 2 For my project for The Physics of Music, I decided to

More information

Troubleshooting Problems Affecting Radio Frequency Communication

Troubleshooting Problems Affecting Radio Frequency Communication Troubleshooting Problems Affecting Radio Frequency Communication Document ID: 8630 Refer to the Cisco Wireless Downloads (registered customers only) page in order to get Cisco Aironet drivers, firmware

More information

RICHARD T ELL ASSOCIATES,INC.

RICHARD T ELL ASSOCIATES,INC. RICHARD T ELL ASSOCIATES,INC. An Evaluation of Test Measurement Data Obtained on the KW-Gard RF Protective Suit March 30, 1998 Prepared for Euclid Garment Manufacturing Company 333 Martinel Drive Kent,

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

Microwave Meter. Instruction Manual

Microwave Meter. Instruction Manual Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted

More information

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS 1. Locate a suitable position inside the building to install the Base Station enclosure where mains power (240V AC) is available

More information

Abracon PTM Introduction to ANFCA Series Flexible Peel & Stick NFC Antennas

Abracon PTM Introduction to ANFCA Series Flexible Peel & Stick NFC Antennas Abracon PTM Introduction to ANFCA Series Flexible Peel & Stick NFC Antennas WWW.ABRACON.COM ANFCA Series Flexible Peel & Stick NFC Antennas Purpose To introduce ANFCA Series, Flexible Peel & Stick NFC

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

Times Microwave Systems Hermetically Sealed Assemblies

Times Microwave Systems Hermetically Sealed Assemblies SCOPE This Specification details the Electrical, Mechanical and Environmental Characteristics of Times Microwave Systems MILTECH 340.34 Diameter Hermetically Sealed Coaxial Transmission Lines. This product

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Information Technology Solutions

Information Technology Solutions Information Technology Solutions Aluminum Sliding Door Assembly Instructions Shield Doors & Windows Bi-fold Door Assembly Instructions For Support Please Call 03 8339 2252 Aluminum Sliding Door Assembly

More information

Video Camera Installation Guide

Video Camera Installation Guide Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to

More information

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast. METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component

More information

Marine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006

Marine HF SSB Installation and Grounding. Anatomy of the Best Tour 2006 Marine HF SSB Installation and Grounding Anatomy of the Best Tour 2006 Marine HF Installation Considerations This document is meant to be an overview of Marine HF radio installation For detailed installation

More information

Annex 113A Description of cable clamp and test setup. (informative) 113A.1 Overview

Annex 113A Description of cable clamp and test setup. (informative) 113A.1 Overview Annex 113A Description of cable clamp and test setup (informative) 113A.1 Overview This annex describes an example of a cable clamp and a a representative methodology that should be used in common-mode

More information

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

EMC Test Chamber Solutions RF Cable Assemblies and Connectors EMC Test Chamber Solutions RF Cable Assemblies and Connectors RF CABLE ASSEMBLY AND CONNECTOR SOLUTONS FOR EMC MMUNTY AND EMSSON COMPLANCE TESTNG E X T N T R A T E D E P T H --> POWER LEVEL: -40.00 dbm

More information

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel What is GigaCrete GigaCrete is a family of products based on low carbon footprint Green ceramic binders

More information

Mounting Instructions. Torque Transducer. A0329 3.2 en

Mounting Instructions. Torque Transducer. A0329 3.2 en Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................

More information

General Thoughts on Generator Set - Acoustic Solutions & Noise Control

General Thoughts on Generator Set - Acoustic Solutions & Noise Control t: 023 81 290160 www.excelpowerltd.co.uk f: 023 81 290260 info@excelpowerltd.co.uk General Thoughts on Generator Set - Acoustic Solutions & Noise Control Written By Steve Delaney A.M.I.O.A. of TAS Ltd

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

EMF shielding by building materials

EMF shielding by building materials EMF shielding by building materials Attenuation of microwave band electromagnetic fields by common building materials The U.S. National Institute of Standards and Technology (NIST) conducted in 1997 extensive

More information

Integral Kit Instructions

Integral Kit Instructions Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware. 14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined

More information

CHAPTER 4. Electromagnetic Spectrum

CHAPTER 4. Electromagnetic Spectrum ELEC4504 Avionics Systems 9 CHAPTER 4. Electromagnetic Spectrum 4.1. Electromagnetic (EM) Waves In free space (or the atmosphere) the electric field is perpendicular to the magnetic field and both are

More information

Physical Specifications (Custom design available.)

Physical Specifications (Custom design available.) Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given

More information

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 9668-11

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D-76863 Herxheim Tel. (07276) 96680 FAX 9668-11 The I-PRO Traveller part no. 11440 Thank you for your purchase, please take your time to digest some of the important building tips and the essential matching/adjustment techniques. You will need 8m of

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

G VYCOR DECK PROTECTOR

G VYCOR DECK PROTECTOR G VYCOR DECK PROTECTOR Self-Adhered Flashing Contractor s Guide DECKS AND DETAIL AREAS For longer lasting decks, install Grace Vycor Deck Protector. FROM THE MAKERS OF G Ice & Water Shield What Self-Adhered

More information

Electromagnetic (EM) waves. Electric and Magnetic Fields. L 30 Electricity and Magnetism [7] James Clerk Maxwell (1831-1879)

Electromagnetic (EM) waves. Electric and Magnetic Fields. L 30 Electricity and Magnetism [7] James Clerk Maxwell (1831-1879) L 30 Electricity and Magnetism [7] ELECTROMAGNETIC WAVES Faraday laid the groundwork with his discovery of electromagnetic induction Maxwell added the last piece of the puzzle Heinrich Hertz made the experimental

More information

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual Field Analyzer FA106 and FA306 Users Manual 1 Contents Contents...2 Preface...3 Chapter 1 Basic Functions...4 1.1 Turning on/off...4 1.2 Choosing the required measuring mode...4 1.3 Picture of front panel...5

More information

At the completion of this guide you should be comfortable with the following:

At the completion of this guide you should be comfortable with the following: This guide provides instructions and best practices for deployment of the Yealink W52P IP DECT phones and repeaters RT10, which is intended for qualified technicians (or administrator) who will deploy

More information

Lightweight Partition Design for Residential and Commercial Buildings

Lightweight Partition Design for Residential and Commercial Buildings Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation

More information

with Component Rating A Simple Perspective

with Component Rating A Simple Perspective Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America

More information

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues

Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Technical Forum Overview and Latest Development of Standards in Human Exposure to Electromagnetic Fields (EMF) Real-life Applications of ICNIRP Guidelines to Various Human EMF Exposure Issues Dr. Brian

More information

On the Application of Computational Electromagnetic Techniques to the Design of Chambers for EMC Compliance Testing

On the Application of Computational Electromagnetic Techniques to the Design of Chambers for EMC Compliance Testing FEATURE On the Application of Computational Electromagnetic Techniques to the Design of Chambers for EMC Compliance Testing C. L Holloway, P. McKenna and R. F. German, EMA Inc., and Lehman Chambers, (303)

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

TEST REPORT. Report No.: A9814.01 109 44. Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept Architectural Testing TEST REPORT Report No.: A9814.01 109 44 Rendered to: BAMCO INC. Middlesex, New Jersey PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept AAMA 508 07, Voluntary Test Method

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information