INSTALLATION -OR- * InFusion controllers have a micro-sd flash card port for backup.
|
|
|
- Rodney Morris
- 9 years ago
- Views:
Transcription
1 INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East, Orem, Utah Telephone: Fax: Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S Overview Vantage s LCAP Series Commercial Enclosures ship with pre-configured modular solutions for commercial, architectural load dimming and switching. The pre-configured designs save time in Design Center and installing. The LCAP32/44M/S series offers the highest amperage dimming and switching options in the LCAP line. Vantage s own forward and reverse phase dimming, use, patent pending, individual load linearization curve settings. Each dimmed load s starting/stopping points can also be set. This technology is exclusive with Vantage and allows for smooth dimming and consistent lighting using mixed lighting types and brands. The LCAP32/44M/S enclosure may be connected to other Vantage enclosures making this design scalable to virtually any size system. Solution 1 Parent-level Enclosure Models Main Enclosure Description LCAP44 44 Architectural Enclosure LCAP32 32 Architectural Enclosure Panel Power Section: LCAP32/44M/S Panel LCAP44M/S, up to 4 Modules Configurations LCAP32M/S, up to 2 Modules Panel Controller Section: LCAP32/44M (contains controller) 1, IC-36-II Controller LCAP32/44S (contains Secondary -OR- Terminal Board) 1, Secondary Terminal Board Part Number Breakdown Actual PN Important Optional Parts COM-HV-BARRIER VA-RRU-1-120V VA-RRU-1-277V VA-EPC-DFS-120V VA-EPC-DFS-277V ENCLOSURE & LID Only PANEL Type LCAP32/44/M/S Optional Modules LCAP32/44M/S with module options Module Type Location 1-4 M LCAP32/44 S See Ordering Key on last page Description Low-Voltage Barrier Emergency Shunt Relay - 120V Emergency Shunt Relay - 277V Emergency Lighting Surface Mount Switch 120V Emergency Lighting Surface Mount Switch 277V o Components using high voltage wiring. Mixed high voltage wiring. o Components using low voltage control signal wiring. o Components using low voltage communication wiring. o Components using high voltage and low voltage connections made inside the enclosure. The enclosure uses built-in barriers to separate high and low voltage wiring. Some designs include the barrier while other designs require the barrier be added by the designer. o High voltage barriers may be installed between 120V/240V/277V load modules. Enclosures may be setup as follows. -OR- o Main Enclosures Containing: One Main Enclosure Terminal Board (36V) and one IC-36-II InFusion Controller, o Secondary Enclosures Containing: One Secondary Enclosure Terminal Board. Enclosure Features / Parts 1. Enclosure can (order LCAP32/44 only (44 shown)). 2. Panel Insert (power section). a. Ground terminals (terminals for upper and lower sections). b. Module Panel Boards Up to 4 modules for 44 and up to 2 Modules for 32. c. Metal isolation barrier between varying voltages. Should be added in Design Center s project design as part of enclosure setup, giving it the correct part number via the position (optional). d. AC Terminal boards installed for module type ordered. e. Terminal board jumpers are installed for lighting control via breakers during construction. NOTE: MDR8CW301 commercial modules do not support either type of terminal jumper boards. 3. Panel Insert (controller section). a. Barrier for IC-36-II controller or secondary terminal board. b. IC-36-II controller or secondary terminal board inside barrier. 4. Enclosure cover, with hinged/vented door allowing easy access when servicing and proper ventilation for convection cooling process. Specifications Specifications LCAP32M / LCAP32S LCAP44M / LCAP44S Cabinet Dimensions HWD 32 x 24 x x 24 x cm x 61cm x 11.6cm 113cm x 61cm x 11.6cm Door Dimensions HWD 32 x 24 x x 24 x cm x 61cm x 2cm 113cm x 61cm x 2cm Panel Insert HWD 29.5 x 21 x x 21 x cm x 53.3cm x 10.6cm 106.7cm x 53.3cm x 10.6cm Weight Enclosure 30 lbs / kg 41 lbs / 18.6 kg Weight Door 15.5 lbs / 7.03 kg 20.7 lbs / 9.39 kg Weight Panel Insert 18.7 lbs / 8.48 kg 23 lbs / kg Number of Modules Up to 2 Up to 4 Load Capacity Up to 24 Up to 48 Line Feeds (breakers) Up to 17 Up to 33 Flash Memory (via controller) Enclosure Finish Galvanized Steel Door Finish Black - Powder Coated Cover vented, hinged Wire copper wire, MIN. of 80 C / 176 F insulation Ventilation maintained 36 front clearance Ambient Operating Temp C / F Ambient Oper. Humidity 5-95% non-condensing UL, CUL, and CE listed yes InFusion controllers have a micro-sd flash card port for backup. Please see: InFusion Controller instruction sheet Visit the Vantage Dealer Site for modules, and emergency switch install sheets. LCAP Enclosure Designs LCAP Series Enclosure Facts. Enclosures must be populated from left to right and top down. o Blank module positions cannot be left between lighting modules in Design Center setup. Enclosures are pre-configured and wired (to the extent possible) using specific combinations of the following components. Installed components are dependent on the enclosure design. LCAP32/44M/S Panel Basic Construction Parts Terminal jumper boards are installed for use during construction to supply power to loads. Modules can then be installed when construction is finished. NOTE:- 8 line feed relay modules do not have a jumper board option. JUMPER BOARDS MJTB or QJUMPER Reminder: visit the Vantage Dealer Site for modules, and emergency switch install sheets. Vantage, 9/2/2015 / IS B Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S page 1 of 6
2 Module Terminal Boards 12 LOAD TSDM-KIT TLM-KIT COMING SOON 8 LineFeed T8LRM-KIT recommends their own or an equivalent wire, (see Vantage Station Bus Wire Specification above) be used in runs between Main enclosures. This is a polarized connection with two + and two screw terminals for in and out wire runs. The maximum wire length for all controllers connected together on one bus should not exceed 2,000ft. using the above wire specification. VOLTAGE BARRIER When adjacent modules use different line voltage feeds (e.g., 120V and 277V) install a voltage barrier between the modules. TUDM-KIT LCAP32/44M Panel Optional Construction Parts EMR. SWITCH VA-RRU-1-12OV (277V) EMR. SWITCH VA-EPC-DFS -12OV (277V) Please see install sheets for emergency switch applications. Installation / Enclosure Mounting Instructions Installation of Vantage LCAP products should be performed or supervised by the Vantage factory and/or a Certified Vantage Installer. Installation and maintenance of high voltage devices should only be performed by licensed, qualified, and competent personnel having appropriate training and experience. CAUTION: Turn Breakers OFF and Check that no Power is ON at the AC Terminal Boards when working in the enclosure or working on lighting fixtures connected to the Module s Loads, etc. Do not allow trimmed wire cuttings to fall into enclosure components as they may cause damage when power is restored. Damage from this type of short will void the warranty. Do not mount enclosures in attics, garages, or crawlspaces, unless room is properly conditioned to conform to ambient room temperature and humidity requirements. Mount enclosure a minimum of 18 from ceiling or floor. National Electrical Code requires a minimum frontal clearance of 36 for the enclosure. Use screws provide for mounting. General Wiring Drill proper size holes in can for running wires in and out of the enclosure. Separate high and low voltage wire run channels. All wire runs in and out of the enclosure should be secured using 2-screw connectors or equivalent as shown at the right. Proper conduit or equivalent wire channels should be used according to local codes and regulations. Proper High Voltage Terminations / Proper Torque: Connector Torque Wire Range MODULE TERMINAL 20 INCH POUNDS AWG CONTROLLER POWER 20 INCH POUNDS AWG Breaker Feeds to Controllers: Vantage recommends that the Main Controller s power be wired to a dedicated circuit breaker. When multiple enclosures containing controllers are in close proximity to one another, it is recommended to share the same breaker to all Main Controllers; no more than nine controllers may be connected to a 20amp breaker allow up to 200W@120VAC per InFusion Controller. Do not share the same breaker with controllers and modules. Vantage Station Bus Wire Specification Vantage wire, part #VDA-0143-BOX or VPLENUM-CABLE 2C, 16AWG / 1.31mm2, twisted, non-shielded, <30pF per foot. Separate a minimum of 12" / 30.5cm from other parallel communication and/or high voltage runs. Main Controller to Main Controller Wiring NOTE: Vantage recommends using Ethernet connections for Controller to Controller communication. Please see the InFusion Controller instruction sheet for additional information. When connecting multiple Main enclosures via the Main Enclosure Terminal Board s Controller Bus screw terminals, Vantage Station Bus Wiring WireLink stations connect to the Station Bus screw terminals on the Main Enclosure Terminal Board. Use Vantage station bus wire, (above). Maximum total station bus wire for each run = 2,000 feet with no station more than 1,000 feet from enclosure (typically the second half of the station bus loops back to enclosure with only one end connected). Station Bus should be separated a minimum of 12" from other parallel communication and/or high voltage runs. Main & Secondary Enclosure to Secondary Enclosure Wiring Connecting a Main enclosure to a Secondary enclosure or Secondary enclosure A to Secondary enclosure B, requires 16/18- gauge 4-conductor twisted, non-shielded wire. Three of the wires are always used to connect a Main enclosure to a Secondary enclosure and chained secondary enclosures. This is a polarized connection with +, and Gnd screw terminals for communication. The 4th wire is for Manual Override and is optional. Each Secondary enclosure bus can support two Secondary enclosures for a maximum of six Secondary enclosures per Main enclosure (see InFusion wiring below). Maximum wiring distance from Main enclosure to Secondary enclosure is 200ft including an A/B Secondary system (e.g., 100ft from Main enclosure to Secondary enclosure A and an additional 100ft from Secondary enclosure A to Secondary enclosure B). Main Terminal Board Terminator If only one or two Main enclosures are used, the Controller Bus Termination switch must be ON. This switch is located on the Enclosure Terminal Board. If more than two Main enclosures are used ONLY the first and last Enclosure Terminal Boards on each controller bus should have the Network Termination switch set to ON. RS-232 (Ports 1-5) for Main Enclosures The Main Enclosure Terminal Board has five RS-232 ports. Use these ports to connect any device that uses RS-232 communication. Only connect one RS-232 device at a time to an RS-232 port. If additional RS-232 ports are needed, Vantage also manufactures an RS-232 Station or, some products like the IRX II, have built-in RS-232 ports. Vantage typically uses RX, TX and GND for communication but does have RTS and CTS for some applications on RS-232 Ports 1 and 2. RS-232 Ports 3-5 only have TX, RX and GND., however, all five ports can use software flow control. The default communication protocol may be changed through Design Center software. Communication protocol parameter settings: Standard baud rates K 7-8 Data Bits Even, Odd, Forced or No Parity 200ft. maximum wiring distance Default protocol for RS-232 communication is: Baud: Parity: None Total bits: 8 Stop bits: 1 RS-485 Connections The Main Enclosure Terminal Board has two RS-485 ports. These ports are connected to the same screw terminals used for Secondary enclosure ports 3 and 4. The ports may not be used for Secondary enclosure support and RS-485 support simultaneously. However, if Secondary enclosure bus ports 3 and/or 4 are free they may be used as RS-485 communication ports. The RS-485 ports are half-duplex, meaning that each port can transmit and receive but not at the same time. Maximum wiring distance for RS-485 ports is 200ft. Vantage, 9/2/2015 / IS B Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S page 2 of 6
3 Possible Ground Loop Issues All RS-232/RS-485 connections between third party equipment and RS-232/RS-485 connections on the Main Enclosure Terminal Board may produce a ground loop. Most often, the connected RS- 232/RS-485 device is not using the same power source or is far away from the Vantage enclosure resulting in a possible ground loop that may produce a data noise condition. If this condition is suspected, Vantage recommends a third party RS-232/RS-485 Opto (optical) Isolation Module. Opto Isolation provides a communications link and is an important consideration if a system uses different power sources, has noisy signals or must operate at different ground potentials. Auxiliary Power The enclosure, Main Enclosure Terminal Board has a 12VDC auxiliary power connection. The 12VDC connection is typically used for one RFE1000 RadioLink Enabler or one RFLC-V232 Enabler. Total power is limited to 250ma. NOTE: Do not connect more than one auxiliary device at a time to this power source. If additional powered devices are needed they must be separately powered with an external, isolated type (usually no ground prong), power transformer. Wiring AC Terminals Keep breaker and load wire runs organized and managed as illustrated. Neutrals Run a separate NEUTRAL for each load connected to dimming devices. Failure to do this may cause loads, sharing the same neutral, to flicker slightly while ramping or dimming a load. The potential for flickering occurs with all dimming systems due to the changing load level coupling to the fixed load through the neutral. MUST MATCH BREAKER WIRE GAUGE TORQUE: 20 INCH POUNDS Manual Override In the unlikely event of a Main Controller failure, the Manual Override can be used to turn selected loads ON. If the system is in override, individual loads can be controlled by dip-switches located on each module in the enclosure. Manual Override control can be extended to other enclosures. It is common to extend Manual Override between a Main enclosure and its Secondary enclosures. It is not recommended to extend Manual Override between Main enclosures. PROPER: Insulation not cut back too far. PROPER: Wire not forced in screw terminal too far. Enclosure Wiring Examples LCAPM Enclosure Terminations: InFusion Secondary Enclosure Terminations: To InFusion Enclosure Board (4C 16-18AWG) To InFusion Secondary Enclosure Board Switch-B (4C 16-18AWG) Vantage, 9/2/2015 / IS B Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S page 3 of 6
4 InFusion Override Wiring Examples: Detail Wiring InFusion Main Enclosures to InFusion Secondary Enclosures (See wire specifications above) InFusion Main Enclosure to Secondary Enclosure Wiring Overview Note the position of the Enclosure Select switch and the Enclosure Bus Termination switch on each Secondary Enclosure Terminal Board. All A boards are homerun to the Controller board and all B boards are homerun to its Parent, A board. The termination switch is OFF for all A boards only if they have a B board connected. The termination switch is On for all B boards. Junction for all Overrides It is also possible to extend Override from one Secondary Enclosure to the next Secondary Enclosure, as long as it daisychains back to the Main Enclosure. Vantage, 9/2/2015 / IS B Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S page 4 of 6
5 Part Number Ordering Key Design Center will generate part numbers automatically as the enclosures are built. This key is for help creating manual orders if needed. ordering key for LCAP32/44M/S part #s for modules & module placement LCAP32/44 M Ships with LCAP32/44 Commercial Enclosure LCAP32/44M Architectural Dimming Panel Main, 2 or 4 module capacity with controller terminal board S LCAP32/44S Architectural Dimming Panel Secondary, 2 or 4 module capacity with secondary terminal board -4 Module Model: Select one module for each location Replace the asterisk with one of the following: 1 MDR8RW101 relay module 120V 2 MDR8RW201 relay module 277V C MDR8CW301 relay module, 8-line feed 120V-277V F SDM12-EM standard dimming module (forward phase) - 120V-277V R EDIMMOD electronic dimming module (reverse phase) - 120V U UDM08-EM universal dimming module (reverse or forward phase) - 120V-277V FUTURE PRODUCT COMING SOON X - Blank module position (Allowed only after populated positions) LCAP32/44M/S Supported Module Types: SDM12-EM 4 LINE FEED 12 LOAD STANDARD DIMMER EDMMOD 2 LINE FEED ELECTRONIC DIMMER MDR8RW101 MDR8RW201 4 LINE FEED RELAYS MDR8CW301 8 LINE FEED RELAYS UDM08-EM 4 LINE FEED COMING UNIVERSAL SOON DIMMER Vantage, 9/2/2015 / IS B Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S page 5 of 6
6 LCAP32M Enclosure Multi-View MULTI-VIEW PANEL VIEW BACK VIEW LCAP44M Enclosure Multi-View MULTI-VIEW PANEL VIEW BACK VIEW Vantage, 9/2/2015 / IS B Commercial Power Enclosure Solutions MODEL: LCAP32M/S & LCAP44M/S page 6 of 6
Applied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels
369344c 04.28.204 LP dimming panels are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Works directly with incandescent, magnetic low
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
BACnet Automation Interface Module (Network Version)
Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP
Remote Power Panels with Breakers
Remote Power Panels with Breakers 8 Series Panels & Enclosures N/A N/A Remote power panels with breakers are available in two different sizes, each of which may be either surfacemounted or recess-mounted,
EQUIPMENT SPECIFICATIONS
EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT
SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical
HSG Engineering Tech Bulletin
Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for
AC and DC Drive System Installation Information
Purpose This document contains the Parker SSD Drives recommendations for installing drive systems. These instructions must be followed for safe and reliable operation. Instructions CODES AND REGULATIONS
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Parallel Redundant Uninterruptible Power Supply
9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS
NSI DIGITAL DIMMING SYSTEM NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS Software Revision 1.41, Version C UL, Mfg Q3/96, and above SPECIFICATIONS Number of Channels: 9800 : 8 channels Output capacity:
Fire Fighter Phone System Installation Instructions
Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone
Reference Design. conference rooms
Reference Design conference rooms Tomaro Design Group conference rooms The modern commercial conference room embraces communication and multi-media technology from projectors and video conferencing, to
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
PowerLogic Sub Meter Display (SMD and SMDOPN)
Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting
2-Pair. Managed SHDSL Ethernet Extender. User s Manual
2-Pair User s Manual 1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet
Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811
Instruction Sheet 1-2003 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch. The
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Job Aid Pre-Installation Information S8500 Media Server
Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for
Operating Instructions. UL325 Compliant Non-monitored
IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet
NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet The NX-591NE-GSM is a microprocessor-controlled GSM interface module used to connect the NetworX series of control panels to GSM cellular networks
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
Configuration Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
RAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.
Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Setting Up and Testing the MAX Hardware
Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
QSE-CI-NWK-E Control Interface
QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices
WIRELESS STATUS MONITOR
INSTALLATION INSTRUCTIONS WIRELESS STATUS MONITOR (WSM or AUWSM) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-032-D Schlage 245 W. Roosevelt Road,
DMX2PWM 9 Channel Dimmer Setup Manual
DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+
Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally.
CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.
7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND
GRX-PWM Pulse Width Modulation Interface
Pulse Width Modulation Interface pwm1 05.30.06 COOPERSBURG, PA 18036 U.S.A. Coopersburg, G 8 BR PA 18036 U.S.A. 144317 GRXTVI 19 P10 CB 0791275 Ratings Load T ype Switched Lowvoltage Load Type Switched
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
PD 100A. Printing data system
PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep
12V Dimmable Driver EL-TMDRVR
Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems
CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Contractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
T1 Backhaul Connectivity Solution All Products :: Application Note
Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments
1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)
000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,
Control Interfaces. GRAFIKR Systems. 369-564a 1 10.25.11 LUT-DMX
369-564a 1 10.25.11 DMX 512 Control Interface Description Allows GRAFIK EyeR lighting controls to operate lighting and other equipment that uses the DMX 512 protocol, including: - Strobes, fiber optic
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
SHDSL LAN EXTENDER H301A. User Manual
SHDSL LAN EXTENDER H301A User Manual Rev. 1.0 Yoda Communications, Inc. Yoda Communications, Inc. Address 2F, No. 3-1, Industry East Road IX, Science Based Industrial Park, HsinChu, Taiwan Tel 886-3-5632323
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation
Stand Alone POTS Fiber Optic System P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit Description & Installation Printed in USA 09/11 TO466 Rev. A Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved
MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved MICRONOR automation components Product MICRONOR MR221 and MR222 series Heavy Duty Geared Limit Switches are for use in the most demanding industrial
PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen 6 439 62 Frillesås
PUSH CV Vi säljer och konsulterar Ledbelysning Utebelysning Innebelysning Led-strip RGB Drivdon HUVUDKONTOR Kungegårdsgatan 7 441 57 Alingsås SÄLJKONTOR Torstensviksvägen 6 439 62 Frillesås 0322-30 30
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
SYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN
INSTLLTION INSTRUTIONS 24" (61.0 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements...
An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!
READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the
ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system
pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Installation Guide Solar Connect-11
Installation Guide Solar Connect-11 Version 1.1 Contents Important Product Information 3 System Registration Form 4 Solar Connect-11 Overview 5 Internet & Power Connections 6 Single Phase CT Connections
