12AT/50AT Series Spin-On Filters
|
|
- Kelly Morton
- 7 years ago
- Views:
Transcription
1 Spin-On Filters 1
2 Applications for Spin-On Filters n Mobile Equipment n Hydrostatic Drives n Industrial Power Units n Reservoir Breathers Often, economic conditions dictate what type of filter is used on a piece of equipment When costs are tight, you need a filter that is inexpensive, yet uncompromising in performance and quality Parker's spin-on filters fit that need They are built to fit demanding design parameters in today's mobile and industrial equipment No compromising Mounting n hole pattern for flexibility Indicator Gauge n Shows at a glance when the canister needs changing Ports n Both NPT and SAE straight thread available Disposable Canister n No mess, oil is contained inside n Easy to handle n Single and double lengths for longer life Interchangeability n Parker canisters fit many competitors' heads Contact Hydraulic Filter Division for part numbers TYPICAL LOCATIONS RETURN RETURN SUCTION BREATHER OFFLINE
3 Code 5C C 3C B Typical Element Performance: Filter Beta Ratios B 5 B B 3 B B Particle Size / Efficiency 5 / 5% / 5% 3 / 5% / 9.7% / 9.7% Actual results are dependent on system flow rates, fluid viscosities, and other parameters. Code 5C C 3C B C- - B- 3B- Typical Element Performance: Filter Beta Ratios B 5 B B 3 B B B B B B 3 Particle Size / Efficiency 5 / 5% / 5% 3 / 5% / 9.7% / 9.7% / 5% / 9.7% / 9.7% 3 / 9.7% Actual results are dependent on system flow rates, fluid viscosities, and other parameters. Beta Efficiency at (X) Rating Particle Size Bx =... 5.% Bx = % Bx = % Bx = % Bx = %.7. ASSEMBLY 15 SUS 3C C 5C ASSEMBLY 15 SUS 3C 5C B C (PSI) PRESSURE DROP (BAR) (PSI) PRESSURE DROP (BAR) (GPM) FLOW (LPM) (GPM) FLOW (LPM) (PSI) PRESSURE DROP (BAR) ASSEMBLY 15 SUS B (PSI) PRESSURE DROP (BAR) - ASSEMBLY 15 SUS 3B B C (GPM) FLOW (LPM) (GPM) FLOW (LPM)
4 Installation and Specification Data Model Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 15 psi (.3 bar) Design Safety Factor:.5:1 Operating Temperatures: - F to 5 F (- C to 7 C) Element Collapse Rating: psid minimum Element Condition Indicators: Gauge: Color coded 15/5 psi Pressure Switch: Normally open +/- psi 5 VDC Vacuum Switch: Normally open 5" +/- 1" Hg 1. 1 VAC Filter Material: Head: Aluminum Canister: Low Carbon Steel Shipping Weights (approximate): 1. lbs. Gauge Port Locations: RI - Right side of inlet LI - Left side of inlet RO - Right side of outlet LO - Left side of outlet 7..7 MAX LI LO RI RO Linear Measure: millimeter inch ¼ - UNC x.31 MIN THREAD DEPTH -TOTAL OPTIONAL 1/ - 7 NPT GAUGE PORT (RIGHT SIDE INLET SHOWN, PLUGGED) INLET OUTLET PORTS (BOTH ENDS) ¾"-1 NPTF OR ¾" SAE MAX MINIMUM. REMOVAL CLEARANCE
5 Installation and Specification Data Model Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 15 psi (.3 bar) Design Safety Factor:.5:1 Operating Temperatures: - F to 5 F (- C to 7 C) Element Collapse Rating: psid minimum Element Condition Indicators: Gauge: Color coded 15/5 psi Pressure Switch: Normally open +/- psi 5 VDC Vacuum Switch: Normally open 5" +/- 1" Hg 1. 1 VAC Spin-On Filters Filter Material: Head: Aluminum Canister: Low Carbon Steel Shipping Weights (approximate): Single length: 3.7 lbs. Double length: 5.3 lbs. Gauge Port Locations: RI - Right side of inlet LI - Left side of inlet RO - Right side of outlet LO - Left side of outlet Linear Measure: millimeter inch Ports: (both ends) 1¼"-11½" NPTF or 1¼" SAE- 5
6 Reservoir Breather Assemblies and Model -3C Air Rating* 1 micron Element 953 Adaptor Kit 97 Sizing Select the proper size canister for the maximum rate of reservoir draw down or air exchange rate. As a rule of thumb, clean pressure drop should be limited to.1 psid (5" H O). -C -5C -3C -C -5C micron 5 micron 1 micron micron 5 micron A pipe flange, weld collar, etc. may be used to connect the canister adaptor kit to the reservoir. Make sure that air is not able to leak around the adaptor. When mounting on the side of the reservoir, make sure the installation is above the surface of the fluid. Recommended canister change out is after 5 hours of operation. More frequent replacement may be required when operated in heavily contaminated areas such as grinding operations, primary metal mills, and on mobile equipment. Under such conditions, increase replacement frequency to every 5 hours. * 99% Removal efficiency for particles larger than the stated size in air. Graphs are for 3C canisters only. Total pressure drop across canister, adaptor, and pipe may be found by adding pressure drops below: + 1.5% for each inch of adaptor or 3/" pipe used. + 3.% for each 3/" elbow used. + 1.% for each inch of adaptor or 1-1/" pipe used. +.% for each 1-1/" elbow used. TYPICAL INSTALLATIONS MOUNTED ON TOP OR SIDE OF RESERVOIR ALLOW 1.5" FOR CANISTER REMOVAL CLEARANCE. 9 DIFFERENTIAL PRESSURE (IN H ) DIFFERENTIAL PRESSURE (PSI) AIR FLOW (SCFM) 3 5 OIL LEVEL CHANGE RATE (GPM)
7 Filter Service Accessory Parts List Filter canisters need to be replaced when the pressure gauge reads the filter bypass setting. For example, if a filter has a 5 psi bypass valve, it needs to be replaced when the pressure gauge reads 5 psi. If no indicator of any kind is used, replace the canister after the first 5 hours of operation, and every 5 hours thereafter. More frequent replacement could be required depending on operating conditions. When servicing a or filter, use the following procedure: Gauge - 15 psi Gauge - 5 psi Pressure switch-15 psi Pressure switch-5 psi Vacuum switch Breather adaptor kit Vacuum gauge Replacement Canisters A. Shut down the main system and release pressure in the filter line. B. Unthread the canister and discard it along with the accompanying seal. A strap wrench may be required. C. Apply a small amount of lubricant to the new canister seal. D. Install the new canister and hand tighten. 5C C 3C B 3B N/A N/A 9773 N/A PSI COLOR BAND (RED) PSI COLOR BAND (RED) bar psi 3. bar psi 3 Indicator Gauge (15 PSI) Indicator Gauge (5 PSI) 1/-7 NPTF 1/-7 NPTF VACUUM SWITCH PRESSURE SWITCH 7
8 How To Order Select the desired symbol (in the correct position) to construct a model code. Example: BOX 1 BOX BOX 3 BOX BOX 5 BOX BOX 7 BOX C N 5 DD N BOX 1: Seals None Buna BOX : Basic Assembly Spin-on (¾" nom.) Spin-on (1¼" nom.) BOX 3 : Length None Single length canister Double length canister (5 AT only) BOX : Canister 5C* C 3C* B 3B ** * Not available in - ** Not available in BOX 5 : Indicator N None BOX : Bypass Setting 5 5 psid psid 3 3 psid X No bypass BOX 7 : Ports BB MM DD OO N H 3/" NPTF SAE-1 1-1/" NPTF SAE- BOX : Gauge Port Location None Inlet and outlet, both sides (all ports drilled and tapped) NOTE: Gauges must be ordered separately. Please note the bolded options reflect standard options with a reduced lead-time. Consult factory on all other lead-time options.
15/40/80CN Series Coreless Medium Pressure Filters
//8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot
More information15/40/80CN Series Medium Pressure Filters
1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)
More informationCoreless Spin-On Filters. 12AS/50AS Series
Coreless Spin-On Filters 12AS/5AS Series Coreless Spin-on Filters 12AS/5AS Series The Smart Alternative to Spin-on Cans! Features: Parker engineers have developed an innovative alternative to the age old
More informationReusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.
APPLICATION RETURN LINE FILTERS Series RF & RFD Pressures to 36 PSI Flows to 3 GPM HYDAC RF and RFD In-Tank Return Line Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationNORMAN FILTER COMPANY PRODUCT OVERVIEW
NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100
More informationAIR OPERATED OIL PUMPS AND KITS
PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model
More informationSMR Series Submicronic Removal Fluid Purifi cation Systems
SMR Series Submicronic Removal Fluid Purifi cation Systems 193 SMR Series Applications The SMR Series is the smart purification solution for fluid flow in the 2-10 GPM (8-38 LPM) range. The SMR contains
More informationVickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93
Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct
More informationAir Eliminators and Combination Air Eliminators Strainers
Description Air Eliminators and Combination Air Eliminator Strainers are designed to provide separation, elimination and prevention of air in piping systems for a variety of installations and conditions.
More informationRMF TANDEM 900 OFF-LINE FILTER SYSTEMS
RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated
More informationOildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
More informationModel 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
More informationEco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
More informationPVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems
185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by
More informationFlow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationUSA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.
SPECIFICATIONS PF1000 Series Fixed Displacement Pumps Also refer to "Checkball Pump Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters
More informationAutomatic Self-Cleaning Strainers
Applications Water and Liquid service Power Industry Cooling water Pulp & Paper Removing fibers Process Equipment Protect equipment Metal & Mining Quenching, blast furnace cooling Automatic Self-Cleaning
More informationNew. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT
e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a
More informationFilters Air Dryers 08
Filters Air Dryers 08 PuraGuard Filter For service new replacement assembly use PuraGuard QC Filter Service 801731 Maintenance Kit 5006788 Rebuild Kit 5006789 Included In Kit 5006788 Included In Kit 5006789
More informationHYDROSTATIC TEST PUMPS
HYDROSTATIC TEST PUMPS MANUAL HYDROSTATIC TEST PUMPS Ideal for testing residential water lines. Also for pressure testing small pressure tanks, sprinkler, boiler and solar systems. Lightweight and easy
More informationPressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations
VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................
More informationHydraulic Pump/Motor Division Hydraulic Pump/Motor Division
Parker Piston Pumps Otsego Core Competency... Piston Pumps PAVC Series : 4 displacements from 33-100 cc/r, 207 Bar, 3000 RPM PVP Series : 9 displacements from 16-140 cc/r, 250 Bar, 3000 RPM PV Plus : 12
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationMONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB
MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP
More informationRexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
More informationHOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999
CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.
More informationEco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:
Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure
More informationInstallation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
More informationThe SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
More informationClean Fuel & Lubricant Solutions
Clean Fuel & Lubricant Solutions Filters Filter Heads Manifolds Kits Fuel Carts hp Filters and Heads DEF TRAP Accessories Why Filter Fuels & Lubricants? Today s sophisticated equipment, such as diesel
More informationBGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:
BGAH Series Medium Pressure Filters Max. 500 l/min. 25 bar In-line solution for a straight pipeline Pre-filtration by magnet column and a full-flow bypass with low hysteresis. Contamination-proof in-out
More informationball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves
2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating
More informationSeries PVP Variable Volume Piston Pumps
Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference
More informationCharts (Section XI) www.accordintl.com Ph. (713) 641-2288 Fax (713) 641-3636 Main PAGE #
Charts (Section XI) Part No. Description Page No. Fraction, Decimal, and Millimeter Conversion Chart 2 Measurement Chart (Metric & Standard) 3 Standard (ANSI B16.5) Flange Dimension Chart 4 Metric Flange
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationPVS Series - Models 185, 600, 1200, 1800 and 2700
PVS Series - Models 185, 600, 1200, 1800 and 2700 Reduce the catastrophic results of water contamination Eliminate water from the hydraulic system The PVS Series Portable Purification Systems, available
More informationDIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:
E X T E N D I N G Y O U R E N E R G Y DIESEL & JET FUEL FILTRATION EQUIPMENT Applications: Back-Up Diesel Generators Gas Turbines Fueling Terminals for Trucks & Buses Marine Mining Railroad Agriculture
More informationThe cylinder head bolts tightening stages have been updated as listed in Table 1.
NUMBER: 07 EPA04 MBE 4000-6 S.M. REF.: 1.2.2 ENGINE: MBE 4000 DATE: November 2007 SUBJECT: CYLINDER HEAD BOLTS TIGHTENING STAGES PUBLICATION: 6SE412 The cylinder head bolts tightening stages have been
More informationIntroduction to Filtration
Introduction to Filtration DEFINITION OF FILTRATION The process by which solid particles are separated from a fluid by passing the fluid through a permeable material that will not let the solid particles
More informationQuiz On Information Learned From Chapter 1
Quiz On Information Learned From Chapter 1 1. Most hydraulic circuits are designed by: A. mechanical engineers. B. fluid power engineers. C. fluid power distributor salesmen. 2. Atmospheric pressure at
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...
More informationTYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationPower Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
More informationCSD WATER REMOVAL FILTERS FOR DIESEL
CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve
More information3M Water Filtration Products. CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings. Installation and Instruction Manual For:
3M Water Filtration Products Installation and Instruction Manual For: CFS01 Series, CFS02 Series, CFS11 Series, and CFS12 Series Housings Installer: Please leave this manual with owner/operator. Owner/Operator:
More informationVariable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
More informationCatalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...
More informationStanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide
Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne
More informationStandard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
More informationScraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
More informationVARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact
More informationLaminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
More informationOil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance
DC/DCS Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance All DC/DCS and Dual Fan models available with internal pressure bypass DC Motor Driven Cooling Fans Are A Low Cost Solution
More information15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar
1/4/8CN Series Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution The CN Series utilizes a cast aluminium head and spin-on bowl
More informationNITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
More informationL31125 4/96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)
L31125 4/96 Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028) EXTENDED PURGE/HEAVY DUTY CANISTER KIT INSTALL ATION INSTRUCTIONS ' A WARNING
More information3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223
3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large
More informationUsed Fluid Handling Portable Used-Oil Gravity Drains
Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)
More informationIMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
More informationIF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
More informationPressure Relief Valves SPV, SPVF
Pressure Relief Valves SPV, SPVF Construction of the Pressure Relief Valves SPV, SPVF Symbol Description The direct spring, sliding piston Pressure Relief Valve SPV/SPVF is intended for inline mounting
More informationPortable Purification Systems Models PVS 185, 600, 1200, 1800, 2700
Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700 www.comoso.com 190 800.696.6165 PVS Series Principles of Operation Contaminated oil is drawn into the Parker Portable Purification System
More informationVickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment
Vickers Vane Pumps Single and Double Vane Pumps Model Series V10, V20, V2010, and V2020 for Industrial Equipment The Power of One Eaton HANSEN GROMELLE There s a certain energy at Eaton. It s the power
More informationTechnical Guide 08/15/14
Technical Guide 08/15/14 1 Table of Contents Contact information.3 Identifying your system..4-8 Model Number Serial number location Parts of your fuel system..9-14 Fuel pump diagram Wire harness schematics
More informationDelta Power Company 4484 Boeing Drive - Rockford, IL 61109
INDEX Description Page Delta Power Rotary Flow Divider, Positive Displacement (Application Data) 36 P Series, Equal Flow Two Sections 39 P Series, Equal Flow Multi-Sections 40 PM Series, Equal Flow Multi-Sections
More information*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
More informationHow To Order A Direct Flow Air Cleaner
Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today
More informationThese features have made Lo Torc valves the choice of high pressure plug value users, worldwide:
LO TORC Plug Valve The high value, dependable performance, and low maintenance requirements of Halliburton Lo Torc valves can help reduce overall operating costs and help cut downtime. These features have
More informationSERVICE PARTS INSTRUCTIONS
WACO MERITOR SERVICE PARTS INSTRUCTIONS Installing the Meritor WABCO System Saver 1000 and 1200 Series Air Dryers For Use on Tractors, Trucks and Buses with Air Brakes Installation Requirements 5 P/N 434
More informationSpill Containment Manholes
Spill Containment Manholes 1-2100 Series OPW and Pomeco Spill Containment Manholes are designed to prevent spilled product from entering the soil near the fill and vapor return riser connections on underground
More informationWatts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
More informationMONO BLOCK DIRECTIONAL CONTROL VALVE TS
SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2
More informationSeries TMM Axial Piston Motor. Technical Information
Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer
More informationB-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment
More informationPipe Valves, Fittings and Nipples Pressures to 15,200 psi
Pipe Valves, Fittings and Nipples MAXIMATOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed by
More informationDruck PV 62x pneumatic/hydraulic pressure stations
GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300
More informationTypical Aluminum GFM Mass Flow Meter
MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.
More informationSELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS TPZ Engine Air Intake Shut Down Valves (Combined Automatic Overspeed and Air Pressure Operated Shut Down Bendix Types) SELECTION, APPLICATION & MAINTENANCE Valve Numbers TPZ-101
More informationSHOWERS 85-100 SHOWERS
SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97
More informationWILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP
WILROY ATEX Approved HYDRAULICALLY ACTUATED DIAPHRAGM PUMP Williams and Milton Roy have combined technologies to design a pump blending the proven mroy hydraulic by-pass diaphragm design with the Williams
More informationMHT. Pressure Filters HIGH PRESSURE INLINE FILTER
MHT Pressure Filters HIGH PEUE INLINE FILTE Pressure Filters MHT MHT 4 MPa ( bar) Port sizes: / / Flow rates: 0 l/min TEHNIAL DATA Max. working pressure: 4 MPa ( bar) Max. testing pressure: 6 MPa (60 bar)
More informationPVH131/141 Variable Displacement Piston Pump - 11 Design
Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationWhat is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008
What is Oil Filtration By Dennis Morgan, Filtration Consultant and President of AMS Filtration April 8, 2008 This is a seemingly simple question with seemingly simple answers. The problem however is because
More informationShut-off & Lockout Valves 1/4" to 1-1/2" port size
Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout
More information1998½-2007 Dodge Ram 5.9L Cummins
9 January 2014 1081130-33 Dodge Cummins Low Fuel Pressure Alarm Light Kit (I-00143) 1 1998½-2007 Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual - Part Number Sequence: 1081130
More informationYELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail
YELLOW JACKET Hose Adapters, Valves, and Parts right to the last detail NEW Valve core tool page 35 EXPANDED LINE Quick couplers page 36 33 1/4" 4-IN-1 BALL VALVE TOOL for vacuum, charge, cores and recovery
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationItem Number Description Type of Gauge Size in " Price
FARIA Euro Perimeter lighted black dial with bold white graphics, black aluminum bezel, contoured white pointer and flat fog resistant lens EURO Item Number Description Type of Gauge Size in " Price 32805
More informationTUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE 1965-82. Part #: HT-2
Part #: HT-2 1965-82 CORVETTE O-RING CONVERSION REAR CALIpER REbUILdING TUTORIAL Choosing a Brake Caliper Rebuild Kit Standard Lip Seals vs. O-Ring Seals Lip seal design seals are used on 1965-1982 Corvette
More informationFailure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
More informationCheck Valves Valve locator
Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()
More informationCompressed Air Filters
Compressed Air Filters Superior Filtration for Increased Productivity What happens when you don t use an air filter? Kaeser Gives You the Air Quality You Require Ambient air contains contaminants that
More informationFRL/AirCare Air Controls & Accessories
FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor
More information