Engine Performance 1500 RPM
|
|
- Kenneth Hart
- 7 years ago
- Views:
Transcription
1 CUMMINS ENGINE COMPANY, INC Columbus, Indiana 4721 ENGINE PERFORMANCE CURVE Basic Engine Model: 3-G4 Engine Critical Parts List: CPL: 2499 (2 Pump / 2 Loop) CPL: 248 (Air-to-AIr) Date: 8May Curve Number: FR-16 (2P/ 2L) FR-162 (Air-to-Air) G-DRIVE 1 Displacement : 3.48 litre (186 in 3 ) Bore : 14 mm (.1 in) Stroke : 16 mm (6. in) No. of Cylinders : 12 Aspiration : Turbocharged and Low Temperature Aftercooled Engine Speed Standby Power Prime Power Continuous Power RPM kwm BHP kwm BHP kwm BHP Engine Performance 1 RPM OUTPUT POWER % kwm BHP kg/ kwm h FUEL CONSUMPTION lb/ BHP h litre/ U.S. Gal/ STANDBY POWER PRIME POWER CONTINUOUS POWER Litre/ 1 RPM Gross Engine Output - kwm CONVERSIONS: (litres = U.S. Gal x 3.78) (Engine kwm = BHP x.746) (U.S. Gal = litres x.2642) (Engine BHP = Engine kwm x 1.34) These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generator set installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications. STANDBY POWER RATING Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 8% average load factor and 2 s of operation per year. This includes less than 2 s per year at the Standby Power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered an emergency. PRIME POWER RATING Applicable for supplying electric power in lieu of commercially purchased power. Prime Power applications must be in the form of one of the following two categories: UNLIMITED TIME RUNNING PRIME POWER Prime Power is available for an unlimited number of s per year in a variable load application. Variable load should not exceed a 7% average of the Prime Power rating during any operating period of 2 s. The total operating time at 1% Prime Power shall not exceed s per year. A 1% overload capability is available for a period of 1 within a 12- period of operation. Total operating time at the 1% overload power shall not exceed 2 s per year. LIMITED TIME RUNNING PRIME POWER Limited Time Prime Power is available for a limited number of s in a non-variable load application. It is intended for use in situations where power outages are contracted, such as in utility power curtailment. Engines may be operated in parallel to the public utility up to 7 s per year at power levels never to exceed the Prime Power rating. The customer should be aware, however, that the life of any engine will be reduced by this constant high load operation. Any operation exceeding 7 s per year at the Prime Power rating should use the Continuous Power rating. CONTINUOUS POWER RATING Applicable for supplying utility power at a constant 1% load for an unlimited number of s per year. No overload capability is available for this rating. Data shown above represent gross engine performance capabilities obtained and corrected in accordance with ISO-346 conditions of 1 kpa (29.3 in Hg) barometric pressure [11 m (361 ft) altitude], 2 C (77 F) air inlet temperature, and relative humidity of 3% with No. 2 diesel or a fuel corresponding to ASTM D2. See reverse side for application rating guidelines. The fuel consumption data is based on No. 2 diesel fuel weight at.8 kg/litre (7.1 lbs/u.s. gal). Power output curves are based on the engine operating with fuel system, water pump and lubricating oil pump; not included are battery charging alternator, fan, optional equipment and driven components. TECHNICAL DATA DEPT. CERTIFIED WITHIN % CHIEF ENGINEER
2 G-DRIVE 2 3-G4 Derate 1 RPM CURVE NO: FR-16 (2 Pump 2 loop) FR162 (Air-to-AIr) DATE: 8May 3 / 122 Percent Derate of Rated Power (%) STANDBY / PRIME 4 / 14 2 / Percent Derate of Rated Power (%) / / 14 CONTINUOUS Reference Standards: BS-14 and DIN-6271 standards are based on ISO-346. Operation At Elevated Altitude and Temperature: For sustained operation above these conditions, derate an additional 9% per m (164 ft) and 1% per 1 C (18 F) Note: Derates shown are based on 1 in H 2 air intake restriction and 2 in Hg exhaust back pressure.
3 CUMMINS ENGINE COMPANY, INC Columbus, Indiana 4721 ENGINE PERFORMANCE CURVE Basic Engine Model: 3-G4 Engine Critical Parts List: CPL: 2499 (2 Pump / 2 Loop) CPL: 248 (Air-to-AIr) Date: 8May Curve Number: FR-16 (2P / 2L) FR-162 (Air-to-Air) G-DRIVE 3 Displacement : 3.48 litre (186 in 3 ) Bore : 14 mm (.1 in) Stroke : 16 mm (6. in) No. of Cylinders : 12 Aspiration : Turbocharged and Low Temperature Aftercooled Engine Speed Standby Power Prime Power Continuous Power RPM kwm BHP kwm BHP kwm BHP Engine Performance 18 RPM OUTPUT POWER % kwm BHP kg/ kwm h FUEL CONSUMPTION lb/ BHP h litre/ U.S. Gal/ STANDBY POWER PRIME POWER CONTINUOUS POWER U.S. Gallons/ 18 RPM Gross Engine Output - BHP CONVERSIONS: (litres = U.S. Gal x 3.78) (kwm = BHP x.746) (U.S. Gal = litres x.2642) (BHP = kwm x 1.34) These guidelines have been formulated to ensure proper application of generator drive engines in A.C. generator set installations. Generator drive engines are not designed for and shall not be used in variable speed D.C. generator set applications. STANDBY POWER RATING Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility power is available. A Standby rated engine should be sized for a maximum of an 8% average load factor and 2 s of operation per year. This includes less than 2 s per year at the Standby Power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered an emergency. PRIME POWER RATING Applicable for supplying electric power in lieu of commercially purchased power. Prime Power applications must be in the form of one of the following two categories: UNLIMITED TIME RUNNING PRIME POWER Prime Power is available for an unlimited number of s per year in a variable load application. Variable load should not exceed a 7% average of the Prime Power rating during any operating period of 2 s. The total operating time at 1% Prime Power shall not exceed s per year. A 1% overload capability is available for a period of 1 within a 12- period of operation. Total operating time at the 1% overload power shall not exceed 2 s per year. LIMITED TIME RUNNING PRIME POWER Limited Time Prime Power is available for a limited number of s in a non-variable load application. It is intended for use in situations where power outages are contracted, such as in utility power curtailment. Engines may be operated in parallel to the public utility up to 7 s per year at power levels never to exceed the Prime Power rating. The customer should be aware, however, that the life of any engine will be reduced by this constant high load operation. Any operation exceeding 7 s per year at the Prime Power rating should use the Continuous Power rating. CONTINUOUS POWER RATING Applicable for supplying utility power at a constant 1% load for an unlimited number of s per year. No overload capability is available for this rating. Data shown above represent gross engine performance capabilities obtained and corrected in accordance with ISO-346 conditions of 1 kpa (29.3 in Hg) barometric pressure [11 m (361 ft) altitude], 2 C (77 F) air inlet temperature, and relative humidity of 3% with No. 2 diesel or a fuel corresponding to ASTM D2. See reverse side for application rating guidelines. The fuel consumption data is based on No. 2 diesel fuel weight at.8 kg/litre (7.1 lbs/u.s. gal). Power output curves are based on the engine operating with fuel system, water pump and lubricating oil pump; not included are battery charging alternator, fan, optional equipment and driven components. TECHNICAL DATA DEPT. CERTIFIED WITHIN % CHIEF ENGINEER
4 G-DRIVE 4 3-G4 Derate 18 RPM CURVE NO: FR-16 (2 Pump 2 loop) FR162 (Air-to-AIr) DATE: 8May 3 Percent Derate of Rated Power (%) Percent Derate of Rated Power (%) STANDBY / PRIME CONTINUOUS / / 14 2 / 77 / / 14 Reference Standards: BS-14 and DIN-6271 standards are based on ISO-346. Operation At Elevated Altitude and Temperature: For sustained operation above these conditions, derate an additional 9% per 1 ft (3 m) and 1% per 1 C (18 F). Note: Derates shown are based on 1 in H 2 air intake restrictions and 2 in Hg exhaust back pressure.
5 Cummins Engine Company, Inc. Engine Data Sheet DATA SHEET : DS-16 ENGINE MODEL : 3-G4 CONFIGURATION NUMBER : D731GX3 DATE : 8May PERFORMANCE CURVE : FR-16 (2P / 2L) FR-162 (A - A) INSTALLATION DIAGRAM CPL NUMBER Fan to Flywheel (2 Pump / 2 Loop): Engine Critical Parts List (2 Pump / 2 Loop) :2499 Fan to Flywheel (Air-to-Air): Engine Critical Parts List (Air-to-Air) :248 GENERAL ENGINE DATA Type... Aspiration... 4-Cycle; Vee; 12-Cylinder Diesel Turbocharged and Low Temperature Aftercooled Bore x Stroke... mm x mm (in x in) 14 x16 (.1 x 6.) Displacement... (litre) in (186) Compression Ratio : 1 Dry Weight,Fan to Flywheel Engine... kg (lb) 312 (664) Wet Weight,Fan to Flywheel Engine... kg (lb) 3112 (686) Moment of Inertia of Rotating Components with FW Flywheel... kg m 2 (lb m ft 2 ) 8.7 (26) Center of Gravity from Rear Face of Flywheel Housing (FH 31)... mm (in) 84 (33.3) Center of Gravity Above Crankshaft Centerline... mm (in) 19 (7.7) Maximum Static Loading at Rear Main Bearing... kg (lb) 9 (21) ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... N m (lb ft) 31 (2286) EXHAUST SYSTEM Maximum Back Pressure... mm Hg (in Hg) 1 (2) AIR INDUCTION SYSTEM Maximum Intake Air Restriction with Dirty Filter Element... mm H 2 O (in H 2 O) 63 (2) with Clean Filter Element... mm H 2 O (in H 2 O) 381 (1) COOLING SYSTEM (Low Temperature Aftercooling Required) Coolant Capacity Engine Only... litre (US gal) 79 (21) Aftercoolers (2 Pump / 2 Loop)... litre (US gal) 12 (3.2) Minimum Pressure Cap... kpa (psi) 69 (1) Jacket Water Circuit Requirements Maximum Coolant Friction Head External to Engine 1 / 18 rpm... kpa (psi) 48 / 69 (7 / 1) Maximum Static Head of Coolant Above Engine Crank Centerline... m (ft) 14 (46) Standard Thermostat (Modulating) Range... C ( F) 82-9 (18-23) Maximum Top Tank Temperature for Standby / Prime Power... C ( F) 14 / 1 (22 / 212) Aftercooler Circuit Requirements (2 Pump / 2 Loop Aftercooling) Maximum Inlet Water Temperature to 77 F... C ( F) 49 (12) Maximum Inlet Water Temperature to Aftercooler... C ( F) 6 (1) Maximum Coolant Friction Head External to Engine 1 / 18 rpm... kpa (psi) 3 / 48 ( / 7) Air-to-Air Core Requirements Maximum Temp. Rise Between Engine Air Inlet and Intake Manifold 1 / 18 rpm C ( F) 33 / 39 (6 / 7) Maximum Air Press. Drop from Turbo AIr Outlet to Intake Manifold 1 / 18 rpm mm (in Hg) 12 / 127 (4 / ) LUBRICATION SYSTEM Oil Idle Speed... kpa (psi) 166 Governed Speed... kpa (psi) (4-6) Maximum Oil Temperature... C ( F) 121 (2) Oil Capacity with OP 133 Oil Pan : High - Low... litre (US gal) (3-3) Total System Capacity (Including Bypass Filter)... litre (US gal) 14 (4.7) FUEL SYSTEM Type Injection System... Bosch P8 LLA Direct Injection Maximum Restriction at Lift Pump with Clean Fuel Pre-Filter... mm Hg (in Hg) 12 (4.) with Dirty Fuel Pre-Filter... mm Hg (in Hg) 23 (8.) Maximum Allowable Head on Injector Return Line (Consisting of Friction and Static Head)... mm Hg (in Hg) 8 (2) Maximum Fuel Flow to Injection Pumps (Left and Right Banks Combined) 1 / 18 rpm... litre / hr (US gph) / 7 (14 / 1) Maximum Fuel Inlet Temperature... C ( F) 71 (1) Maximum Return Flow... 1 / 18 rpm... litre / hr (US gph) 3 / (14 / 14) G-DRIVE
6 G-DRIVE 6 ELECTRICAL SYSTEM Cranking Motor (Heavy Duty, Positive Engagement)... volt 24 Battery Charging System, Negative Ground... ampere 3 Maximum Allowable Resistance of Cranking Circuit... ohm.2 Minimum Recommended Battery Capacity Cold 1 C ( F) and Above... F CCA 12 Cold C to 1 C (32 F to F)... F CCA 128 Cold -18 C to C ( F to 32 F)... F CCA 18 COLD START CAPABILITY Minimum Ambient Temperature for Cold Start with 8 watt Coolant Heater to Rated Speed... C ( F) -7 (2) Minimum Ambient Temperature for Unaided Cold Start to Idle Speed C ( F) 7 (4) Minimum Ambient Temperature for NFPA11 Cold Start (9 F Minimum Coolant Temperature)... C ( F) (32) PERFORMANCE DATA All data is based on: Engine operating with fuel system, water pump, lubricating oil pump, air cleaner and exhaust silencer; not included are battery charging alternator, fan, and optional driven components. Engine operating with fuel corresponding to grade No. 2-D per ASTM D97. ISO 346, Part 1, Standard Reference Conditions of: Barometric Pressure : 1 kpa (29.3 in Hg) Air Temperature : 2 C (77 F) Altitude : 11 m (361 ft) Relative Humidity : 3% Air Intake Restriction : 24 mm H 2 O (1 in H 2 O) Exhaust Restriction : 1 mm Hg (2 in Hg) Steady State Stability Band at any Constant Load... % +/-.2 Estimated Free Field Sound Pressure Level of a Typical Generator Set; Excludes Exhaust Noise; at Rated Load and 7. m (24.6 / 18 rpm... dba 91 / 93 Exhaust Noise at 1 m Horizontally from Centerline of Exhaust Pipe Outlet Upwards at / 18 rpm... dba 128 / 131 STANDBY POWER PRIME POWER 6 hz hz 6 hz hz Governed Engine Speed... rpm Engine Idle Speed... rpm Gross Engine Power Output... kw m (BHP) 1112 (149) 97 (13) 17 (13) 88 (118) Brake Mean Effective Pressure... kpa (psi) 2427 (32) 244 (369) 2199 (319) 231 (33) Piston Speed... m / s (ft / min) 9.9 (1949) 8.3 (1634) 9.9 (1949) 8.3 (1634) Friction Horsepower... kw m (BHP) 82 (11) 8 (78) 82 (11) 8 (78) Engine Jacket Water Flow at Stated Friction Head External to Engine: psi Friction Head... litre / s (US gpm) 17. (27) 14.2 (22) 17. (27) 14.2 (22) Maximum Friction Head... litre / s (US gpm) 16. (262) 13.7 (217) 16. (262) 13.7 (217) Engine Data with Dry Type Exhaust Manifold Intake Air Flow... litre / s (cfm) 134 (284) 1 (213) 12 (26) 94 (2) Exhaust Gas Temperature... C ( F) 2 (97) 7 (17) 49 (92) 6 (1) Exhaust Gas Flow... litre / s (cfm) 367 (777) 298 (631) 328 (696) 27 (82) Air to Fuel Ratio... air : fuel 2 : 1 22 : : : 1 Radiated Heat to Ambient... kw m (BTU / min) 13 (746) 11 (641) 11 (66) 1 (86) Heat Rejection to Jacket Water Coolant... kw m (BTU / min) 36 (288) 33 (1894) 34 (193) 32 (181) Heat Rejection to Exhaust... kw m (BTU / min) 74 (4213) 67 (38) 66 (3764) 6 (3399) Engine Aftercooler Data Heat Rejection to Aftercooler... kw m (BTU / min) 27 (142) 17 (96) 21 (1212) 14 (824) Aftercooler Water Flow at Stated Friction Head External to Engine: 2 psi Friction Head... litre / s (US gpm).4 (8) 4. (71).4 (8) 4. (71) Maximum Friction Head... litre / s (US gpm). (8) 4.4 (68). (8) 4.4 (68) Charge Air Flow... kg/ min (lb / min) 93 (2) 7 (14) 87 (192) 66 (14) Turbocharger Compressor Outlet Pressure... mm Hg (in / Hg) 189 (73) 134 (6) 1666 (66) 1374 (4) Turbocharger Compressor Outlet Temperature... C ( F) 22 (39) 177 (3) 183 (36) 16 (33) N.A. - Data is Not Available N/A - Not Applicable to this Engine TBD - To Be Determined ENGINE MODEL : DATA SHEET : DATE : 3-G4 DS-16 8May
4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm
The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance
More information(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS
6BTA5.9 F1 FIRE PUMP ENGINE /-- SPECIFICATIONS Four Stroke Cycle, Turbocharged-Aftercooled, In-Line, 6 Cylinder Diesel Engine LISTED AGENCY RATINGS 182 HP O 1760 RPM 208 HP O 2100 RPM Bore and Stroke 4.02
More informationC18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm
CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression
More information1100 Series 1104C-44TAG2 Diesel Engine ElectropaK 99.5 kwm @ 1500 rpm
Building upon Perkins proven reputation within the power generation industry, the Perkins 1100 Series range of ElectropaK engines now fit even closer to the needs of their customers. With this 1104C-44TAG2
More information3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm
Marine Auxiliary Engine SPECIFICATIONS 3304B 56 bkw (75 bhp) 100 mhp @ 1200 rpm Shown with Accessory Equipment I-4, 4-Stroke-Cycle-Diesel Emissions...IMO compliant Displacement... 7.0 L (425 cu. in.) Bore...
More information1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.
Diesel Truck Engine 3126B 175-330 hp 420-860 @ 1440 rpm Peak CATERPILLAR ENGINE SPECIFICATIONS 6-Cylinder, 4-Stroke-Cycle Diesel Bore in (mm)... 4.33 (110) Stroke in (mm)... 5.0 (127) Displacement cu in
More informationSection 10 Maintenance Specifications
Page 10-1 Section Contents Page General Engine Data...10-3 Fuel System Specifications...10-4 Lubricating Oil System Specifications...10-4 Cooling System Specifications...10-4 Air Intake System Specifications...10-5
More informationDiesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
More information3516 Industrial Engine
CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle Diesel Bore...170.0 mm (6.69 in) Stroke...190.0 mm (7.48 in) Displacement... 69.06 L (4,214.3 in 3 ) Aspiration...Turbocharged / Aftercooled Compression Ratio...13.0:1
More informationTechnical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
More informationSection 10 Maintenance Specifications
Page 10-1 Section Contents Page General Engine Data...10-3 Fuel System Specifications...10-3 Lubricating Oil System Specifications...10-4 Cooling System Specifications...10-4 Air Intake System Specifications...10-4
More informationDIESEL GENERATOR SETS
DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
More informationP 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
More informationSpecifications for Volkswagen Industrial Engine
Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or
More informationGEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory
More informationSection 11 - System Diagrams
Section 11 System Diagrams Page 11-1 Section 11 - System Diagrams Section Contents Page Overview...11-3 Flow Diagram, Fuel System...11-4 Flow Diagrams, Lubricating Oil System...11-5 Flow Diagrams, Cooling
More informationDIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET
DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA
More informationSection 6 - System Diagrams
Section 6 System Diagrams Page 6-1 Section 6 - System Diagrams Section Contents Page Overview...6-3 Flow Diagram, Fuel System...6-4 Flow Diagrams, Lubricating Oil System...6-5 Flow Diagrams, Cooling System...6-8
More informationDLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
More informationDIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption
IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,
More informationDiesel Generator Set Model DFHC 60 Hz
Diesel Generator Set Model DFHC 60 Hz 900 kw, 1125 kva Standby 818 kw, 1023 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
More informationAGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ
Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator
More information1013 E. The engine for agricultural equipment.
1013 E. The engine for agricultural equipment.... -186 kw at 2300 rpm These are the characteristics of the 1013 E: Modern water-cooled 4- and 6-cylinder in-line engine Turbocharging with charge air cooling
More informationSTANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts
DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,
More informationHow To Control A Power Command Powerplant
Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power
More informationINDUSTRIAL ENGINE RATINGS GUIDE
INDUSTRIAL ENGINE RATINGS GUIDE Table of Contents Highly Regulated/Lesser Regulated For purposes of this Guide, Highly Regulated refers to engines that meet stringent emission standards in effect in the
More informationan EnPro Industries company POWERSolutions
an EnPro Industries company POWERSolutions Steadfast Performer, Trustworthy Reliability, and Relentless Dependability The FM/ALCO engine, a world renowned name well established as a workhorse and prime
More informationSTANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 2500 ekw 3125 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
More informationHow To Use A Cat Diesel Engine
DIESEL GENERATOR SET STANDBY 440 ekw 550 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More informationSTANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
More informationSTANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts
DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More informationDiesel Generator Set Model DFMB 60 Hz
Diesel Generator Set Model DFMB 60 Hz 1500 kw, 1875 kva Standby 1250 kw, 1563 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
More information912. The engine for construction equipment.
912. The engine for construction equipment....... 24-82 kw at 1500-2500 min -1 These are the characteristics of the 912: Air-cooled 3-, 4-, 5-, 6-cylinder naturally aspirated in-line-engines. Direct injection.
More informationGEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system
More informationCREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel. www.hatz-diesel.com
CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C Hatz Diesel EN www.hatz-diesel.com Exhaust gas recirculation (EGR) For years already the Hatz 4L42C has been successfully fitted with a robustly
More informationDIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption
DIESEL GENERATOR SET STANDBY 560 ekw 700 kva Caterpillar is leading the power generation market place with power solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More informationSTANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
More informationNATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts
GAS GENERATOR SET NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts Image shown may not reflect actual package Caterpillar is leading the power generation marketplace with power solutions
More informationDiesel Generator Set Model DGDK 60 Hz
Diesel Generator Set Model DGDK 60 Hz 125 kw, 156 kva Standby 113 kw, 141 kva Prime Description The Cummins Power Generation DG-series commercial generator set is a fully integrated power generation system
More informationFault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1
Fault codes DM1 Industrial engines DC09, DC13, DC16 Marine engines DI09, DI13, DI16 03:10 Issue 5.0 en-gb 1 DM1...3 Abbreviations...3 Fault type identifier...3...4 03:10 Issue 5.0 en-gb 2 DM1 DM1 Fault
More information3516B Offshore Generator Set
3516B Offshore Generator Set 1648 ekw (2060 kva) 1717 bkw (2303 bhp) 50 Hz (1500 rpm) Actual configuration may vary from displayed image CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle-Diesel Emissions...
More informationThe Yachtmans Choice...
Ref: 1740, Nov 2015 The Yachtmans Choice... A competitive price 10 to 150 hp, engineered in the UK Advanced, compact, quiet reliable engines Easy engine replacement, with our special feet option Amazing
More informationSTANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 1500 ekw 1875 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
More informationSTANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm 11000 Volts
DIESEL FEATURES GENERATOR SET STANDBY 3200 ekw 4000 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched
More informationXQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)
RENTAL Standby Prime Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) Shown with optional trailer FEATURES EPA TIER 4 AND CARB CERTIFIED
More informationWÄRTSILÄ 50DF PRODUCT GUIDE
WÄRTSILÄ 50DF PRODUCT GUIDE Introduction Introduction This Product Guide provides data and system proposals for the early design phase of marine engine installations. For contracted projects specific
More informationAnnex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
More informationMagnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
More informationFull Line-Up of EGS-Series Generator Sets to Meet Your Requirements
Full LineUp of EGSSeries Generator Sets to Meet Your Requirements EGS45BS6 EGS65BS6 EGS120BS8 EGS160BS8 Open Type EGS456 EGS656 EGS1208 EGS1608 1/4 Rated Output Frequency 50Hz 60Hz 50Hz 60Hz 50Hz 60Hz
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
More informationNATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS
GAS GENERATOR SET NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS Image shown may not reflect actual package Caterpillar is leading the power generation
More informationSTANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 3000 ekw 3750 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationAmbient Temperature Operation and Matching MAN B&W Two-stroke Engines
Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines Content Introduction...5 Standard ambient matched engine...5 Operating at high seawater with standard matched engine...6 Non-standard
More informationNew 27 hp 2 Cylinder Liquid-Cooled Engine
New 27 hp 2 Cylinder Liquid-Cooled Engine Introducing the new 27 hp Liquid-Cooled Vanguard 2/LC Engine A cooler, smoother, longer running commercial engine. That s the liquid-cooled advantage of the Vanguard
More informationCentrifugal Fans and Pumps are sized to meet the maximum
Fans and Pumps are sized to meet the maximum flow rate required by the system. System conditions frequently require reducing the flow rate. Throttling and bypass devices dampers and valves are installed
More informationC18 Diesel Oilfield Generator Set
C18 Diesel Oilfield Generator Set 545 ekw (680 kva) 60 Hz 480 Volts 1800 rpm CATERPILLAR ENGINE SPECIFICATIONS C18 In-Line 6, 4-Stroke-Cycle water-cooled diesel Bore... 145 mm (5.71 in.) Stroke... 183
More informationStandby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:
Standby Generators Liquid-Cooled Gas Engine 1 of 9 INCLUDES: Two Line LCD Tri-Lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System
More informationUS Heavy Duty Fleets - Fuel Economy
US Heavy Duty Fleets - Fuel Economy Feb. 22, 2006 Anthony Greszler Vice President Advanced Engineering VOLVO POWERTRAIN CORPORATION Drivers for FE in HD Diesel Pending oil shortage Rapid oil price increases
More informationNote: This information obtained from internet sources and not verified- use at your own risk!!!!
Cummins Engine Diagnostic Fault Codes for 2003 and later engines (generally for 2004 and later Alpines; see page 13 for earlier engine diagnostic codes): Note: This information obtained from internet sources
More informationIGSA POWER GENERATION SYSTEMS
IGSA POWER GENERATION SYSTEMS MODEL: GSDD20600S. MTU, 12V1600G80S, 1800 RPM, 60 HZ. CAPACITY KW KVA 600 750 Reference Conditions ISO 3046: Intake air temperature Side altitude above sea level Charge air
More informationWÄRTSILÄ 34DF PRODUCT GUIDE
WÄRTSILÄ 34DF PRODUCT GUIDE Copyright by WÄRTSILÄ FINLAND Oy All rights reserved. No part of this document may be reproduced or copied in any form or by any means (electronic, mechanical, graphic, photocopying,
More informationV-MAC III Fault Assignments
V-MAC III Fault Assignments ELECTRICAL FAULTS Stp Circuit Failure Blink Sequence 4 Engine Oil Pressure Low Voltage / Open 1 1 P 100 4 128/143 4 Engine Oil Pressure High Voltage 1 1 P 100 3 128/143 9 Barometric
More informationAir Induction Systems
Air Induction Systems Air Supply Requirements of Diesels All internal combustion engines need an adequate supply of air that is clean, dry, filtered, fresh, and relatively cool. Adequate Supply Diesel
More informationEVERY ROUTE. ISB FOR SCHOOL BUS APPLICATIONS
EVERY ROUTE. TM ISB FOR SCHOOL BUS APPLICATIONS SCHOOL BUS APPLICATIONS. The Cummins ISB is the perfect engine to power your school bus. Reliable, efficient and quiet, the ISB delivers the power you need
More informationINDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK
INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single
More informationRENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES
XQ230 SOUND ATTENUATED DUAL VOLTAGE 50/60 Hz Arrangement shown with optional trailer FEATURES EMISSIONS EPA Tier 3 and CARB Emissions Certified for non-road mobile applications at all 60 Hz and 50 Hz ratings
More informationPower kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1
K3 WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor
More informationTECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength
More informationTHERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationPower kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8
SILENT PACK AIR-COOLED SINGLE PHASE 60 HZ INT. TIER IV DIESEL Generating Rates SERVICE PRP STANDBY Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationEnergy Savings through Electric-assist Turbocharger for Marine Diesel Engines
36 Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines KEIICHI SHIRAISHI *1 YOSHIHISA ONO *2 YUKIO YAMASHITA *3 MUSASHI SAKAMOTO *3 The extremely slow steaming of ships has become
More informationLOAD BANK TESTING PROCEDURE
LOAD BANK TESTING PROCEDURE APPENDIX G SPS-G-1 of 9 I. General GENERATOR LOAD BANK TESTING AND ENGINE TESTING A. Provide all equipment, labor, materials and supervision necessary to test the stand-by diesel
More information3516B Offshore Emergency Generator Set
3516B Offshore Emergency Generator Set 1825 ekw (2281 kva) 1901 bkw (2549 bhp) 60 Hz (1800 rpm) Actual configuration may vary from image shown CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle-Diesel Emissions...
More informationEngine Cooling. 2004 Cummins Power GenerationAll copies are uncontrolled
Engine Cooling Liquid cooled engines are cooled by pumping a coolant mixture through passages in the engine cylinder block and head(s) by means of an engine driven pump. The most common generator set configuration
More informationREMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
More informationEngine Heat Transfer. Engine Heat Transfer
Engine Heat Transfer 1. Impact of heat transfer on engine operation 2. Heat transfer environment 3. Energy flow in an engine 4. Engine heat transfer Fundamentals Spark-ignition engine heat transfer Diesel
More informationDiagnostic Fault Codes For Cummins Engines
Section - Diagnostic Fault Codes For Cummins Engines Applies to Engine Models T, T, QSL T, QSM, QS, QSK9, QSK, QST, QSK//8 Note: These fault codes are current at date of publication. Always refer to engine
More informationCummins Westport, Inc. Engine Overview. March 2015
Cummins Westport, Inc. Engine Overview March 2015 Cummins Westport Inc. (CWI) A Cummins JV Company CWI was established in 2001 as a 50/50 joint venture company between Cummins Inc and Westport Innovations.
More informationPerfectly Adapted. ISL Euro 6 Gas Engine 250-320PS
Perfectly Adapted ISL Euro 6 Gas Engine 250-320PS Cummins ISL-G The ISL G is the natural choice in alternative-fuel engine technology. With industry leading performance, it combines all the advantages
More informationTECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,
More informationTurbo Tech 101 ( Basic )
Turbo Tech 101 ( Basic ) How a Turbo System Works Engine power is proportional to the amount of air and fuel that can get into the cylinders. All things being equal, larger engines flow more air and as
More informationHFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO
D10 WATER-COOLED THREE PHASE 50 HZ STAGE 2 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 100 107 Power kw 79 86 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132
More informationHEAVY-DUTY, REDEFINED. REDEFINED.
HEAVY-DUTY, REDEFINED. TO GET YOUR TOUGHEST JOBS DONE, you need an engine that works even harder than you do. That s why Caterpillar offers the CT13 engine for our vocational trucks. It delivers every
More informationTypical ECM/PCM Inputs
Typical ECM/PCM Inputs The computer system components fall into two categories: sensors (inputs) and controlled components (outputs). Each system has sensors. Not every system has all the ones listed,
More informationSG080 9.0L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG080 80 kw. Standby Power Rating 80 kw 100 kva 60 Hz
SG080 9.0L Industrial Spark-Ignited Generator Set EPA Certified Stationary Emergency SG080 80 kw Power Rating 80 kw 100 kva 60 Hz Prime Power Rating* 72 kw 90 kva 60 Hz *EPA Certified Prime ratings are
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4016TAG2A diesel engine Newage/Stamford PI734F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
More informationSD010 2.4L. Industrial Diesel Generator Set. SD010 10 kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.
SD010 2.4L Industrial Diesel Generator Set EPA Certified Stationary Emergency SD010 10 kw 1 of 6 Power Rating 10 kw 12.5 kva 60 Hz Prime Power Rating* 9 kw 11 kva 60 Hz *EPA Certified Prime ratings are
More informationPower kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1
E10 (HIGH SPEED) WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at
More informationMarine Generating Sets 3.7 to 50 kva
Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating
More informationD6R Series III Track-Type Tractor
D6R Series III Track-Type Tractor Engine Engine Model Cat C9 ACERT Net Power ISO 9249 138 kw 185 hp Engine XL/XW/LGP Net Power ISO 9249 149 kw 200 hp Weights Operating Weight 18 669 kg 41,159 lb Shipping
More information307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights
307E Mini Hydraulic Excavator Bucket Engine Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo Net Power 41.5 kw (55.6 hp) Gross Power @ 2,000 rpm 43 kw (57.6 hp) Weights Operating Weight 6800
More informationAPS100 Rental Generator Set Specification
BARTONVIE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBA * MOBERY * ROCK FAS * SPRINGFIED * URBANA APS100 Rental Generator Set Specification STANDBY 100 kw 60 Hz/PRIME 90 kw 60 Hz FEATURES EPA TIER
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG3A diesel engine Stamford HCI 634 H alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
More informationCUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG2A diesel engine Newage/Stamford HCI634G alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
More informationEngine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )
Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 ) Table of Contents 1. General technical description 2. Specification of the equipment 2.1 Diesel / gas unit 2.2 Alternator
More information