C18 Diesel Oilfield Generator Set
|
|
|
- Kelly Rich
- 9 years ago
- Views:
Transcription
1 C18 Diesel Oilfield Generator Set 545 ekw (680 kva) 60 Hz 480 Volts 1800 rpm CATERPILLAR ENGINE SPECIFICATIONS C18 In-Line 6, 4-Stroke-Cycle water-cooled diesel Bore mm (5.71 in.) Stroke mm (7.2 in.) Displacement L ( cu. in.) Compression Ratio :1 Aspiration Air-to-Air Aftercooled Fuel System... MEUI Governor Type.. Caterpillar ADEM A4 control system Package Weight (estimated) kg (11,095 lb.) Image shown may not reflect actual package. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES Ready to Run Shipped from the factory complete and ready to run Fuel/Emissions Strategy Tier 2 Enclosures (design to order) Sound attenuated Weather protective Single-Source Supplier Fully prototype-tested with certified torsional vibration analysis available Factory-designed systems built at Caterpillar ISO 9001:2000 certified facilities Worldwide Product Support Caterpillar dealers provide extensive post-sale support including maintenance and repair agreements. Caterpillar dealers fill 99.7 percent of parts orders within 24 hours. Caterpillar dealers have over 2,100 dealer branch stores operating in 200 countries. The Cat S O S SM program cost-effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products. Cat C18 Tier 2 ATAAC Diesel Engine Utilizes ACERT Technology Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke diesel engine combines consistent performance and excellent fuel economy with minimum weight Electronic engine control Cat Generator Designed to match performance and output characteristics of Caterpillar diesel engines 2/3 pitch minimizes harmonic distortion and facilitates parallel operation UL 1446 Recognized Class H Insulation Cat EMCP 3 Control Panels EMCP 3.1 offers basic engine/generator monitoring, metering, and protection. Segregated low voltage (AC/DC) accessory box provides single point access to accessory connections Panel lights Web Site For all your petroleum power requirements, visit LEHW Page 1 of 8
2 STANDARD EQUIPMENT Air Inlet System Dual element air cleaner Service indicator Control Panels EMCP 3.1 (package mounted) Controls Electronic governor Cooling System Radiator with guard sized for 50 C Low coolant level sensor Coolant level sight gauge Coolant drain line with valve Fan and belt guards Caterpillar Extended Life Coolant Exhaust System Turbo outlet elbow Fuel System Primary fuel filter with integral water separator Secondary fuel filters Fuel priming pump Fuel pressure gauge Flexible fuel lines Generator Self excited Class H insulation Class H temperature rise Random wound Voltage regulator Power terminal strip connections IP23 Protection CDVR 3-phase sensing Power center Governor ADEM A4 Lube System Lubricating oil and filter Oil drain line with valves Fumes disposal Dipstick Mounting System Oilfield skid base Hard mounted Starting/Charging System 45-amp charging alternator 24-volt starting motor(s) Batteries with rack and cables Battery disconnect switch General Paint Caterpillar yellow except rails and radiators (gloss black) Flywheel and flywheel housing SAE No. 1 OPTIONAL EQUIPMENT Air Inlet System Heavy-duty air cleaner with precleaner Control Panels EMCP 3.2 provides comprehensive monitoring, metering, and protection including: power metering, protective relaying and MODBUS communication. EMCP 3.3 provides all of the EMCP 3.2 features and adds the ability to expand the system for advanced engine and generator monitoring. Local alarm and remote annunciator modules Narrow base OPTIONAL EQUIPMENT (continued) Exhaust System Industrial, residential, and critical mufflers Stainless steel exhaust flex and ANSI weld flange Generator Permanent magnet conversion for self-excited generators Oversize and premium generators Space heaters only available with permanent magnet excitation generators Governor Load share module Starting/Charging System Jacket water heater Block heater Oversize batteries SPECIFICATIONS Cat Generator Voltage V Excitation... Self excited Pitch... 2/3 Number of poles... 4 Number of leads Insulation UL 1446 Recognized Class H...with tropicalization and antiabrasion (consult your Caterpillar dealer for available voltages) IP Rating... Drip Proof IP22 Alignment... Pilot Shaft Overspeed capability % of rated Wave form deviation (line-to-line) % Voltage regulation Less than ± 1/2% (steady state)...less than ± 1/2% (with 3% speed change) Harmonic Distortion Less than 5% Cat Control Panel EMCP 3 Series Controls 24-Volt DC control EMCP 3.1 (standard) CSA/CE NEMA 1, IP22 enclosure Run/Auto/Stop control True RMS metering, 3-phase Speed adjust Voltage adust (optional) Digital indication for: - rpm - Operating hours - Oil pressure - Coolant temperature - System DC volts - L-L volts, L-N volts, phase amps, Hz - ekw, kva, kvar, kw-hr, % kw, PF (*) Shutdowns - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) Programmable protective relaying functions: (*) - Under and over voltage - Under and over frequency - Reverse power - Overcurrent MODUS isolated data link (RS-485 half-duplex) supports serial communication at data rate up to kbaud (*) (*) Available on EMCP 3.2 and EMCP 3.3 Single location customer connector point Consult your Caterpillar dealer for available voltages LEHW Page 2 of 8
3 TECHNICAL DATA Open Generator Set 1800 rpm/60 Hz/480 Volts EPA Certified Tier 2 DM8522 Generator Set Package Performance Genset Power 0.8 pf ekw 545 Genset Power Rating with fan kva 680 Coolant to Aftercooler Coolant to Aftercooler Temperature (maximum) C (F ) 49 (120) Fuel Consumption 100% Load with fan L/hr (Gal/hr) (39.9) 75% Load with fan L/hr (Gal/hr) (32.6) 50% Load with fan L/hr (Gal/hr) 89.3 (23.6) Cooling System 1 Ambient Air Temperature C (F ) 52 (125.6) Air Flow Restriction (system) kpa (in. water).12 (.50) Air Flow rated speed for radiator arrangement) m 3 /min (cfm) 1866 (65,888) Engine Coolant Capacity with Radiator/Expansion Tank L (gal) 61 (16.1) Engine Coolant Capacity L (gal) 20.8 (5.5) Radiator Coolant Capacity L (gal) 40.2 (10.6) Inlet Air Combustion Air Inlet Flow Rate m 3 /min (cfm) 46.3 (1635.1) Exhaust System Exhaust Stack Gas Temperature C (F ) (964.8) Exhaust Gas Flow Rate m 3 /min (cfm) (4576.8) Exhaust System Backpressure (maximum allowable) kpa (in. water) 10 (40.2) Heat Rejection Heat Rejection to Coolant (total) kw (Btu/min) 240 (13,660) Heat Rejection to Exhaust (total) kw (Btu/min) (32,586) Heat Rejection to Atmosphere from Engine kw (Btu/min) 97 (5.539) Heat Rejection to Atmosphere from Generator kw (Btu/min) 21.9 (1245.4) Alternator 2 Motor Starting 30% Voltage Dip skva Frame 593 Temperature Rise C (F ) 105 (221) Emissions (Nominal) 3 NOx g/hr (lb/hr) 4,287 (9.45) CO g/hr (lb/hr) 340 (.75) HC g/hr (lb/hr) 10 (.02) PM g/hr (lb/hr) 27 (.06) 1 Ambient capability at 300 m (984 ft) above sea level. For ambient capability at other altitudes, consult your Caterpillar dealer. Air flow restriction (system) is added to existing restriction from factory. Generator temperature rise is based on a 40 C (104 F) ambient per NEMA MG Generator temperature rise is based on a 40 C (104 F) ambient per NEMA MG Emissions data measurement procedures are consistent with those described in EPA CFR 40 Part 89, Subpart D & E and ISO for measuring HC, CO, PM, and NOx. Data shown is based on steady state operating conditions of 77 F, in. HG and number 2 diesel fuel with 35 API and LHV of 18,390 btu/lb. The nominal emissions data shown is subject to instrumentation, measurement, facility, and engine-to-engine variations. Emissions data is based on 100% load and thus cannot be used to compare to EPA regulations which use values based on a weighted cycle. LEHW Page 3 of 8
4 C18 OIL FIELD GENERATOR SET PACKAGES 60 Hz Standard 50 Hz Standard Engine Model C18 C18 C18 ekw Rating kva Rating rpm Rated PF Temperature Rise 105 C 105 C 105 C Tilt Requirements 5 Static 5 Static 5 Static Insulation Class H H H Overload 50%/2 min. 50%/2 min. 50%/2 min. Excitation SE SE SE Voltage Voltage Regulator CDVD CDVD CDVD Configuration 1-Brg 1-Brg 1-Brg Coastal Protection Yes Yes Yes Space Heater Opt. Opt. Opt. Construction RW RW RW Short Circuit Current 300%/10 sec. 300%/10 sec. 300%/10 sec. Frame Size Generator Terminal Box Terminal box shall be standard with terminals on the right side, top entry or rear depending on size. Normal cable entrance shall be from the top. LEHW Page 4 of 8
5 C18 OIL FIELD GENERATOR SET PACKAGES OPTIONAL Engine Model 60Hz 50Hz C18 C18 C18 C18 C18 C18 C18 ekw Rating kva Rating rpm Rated PF Temperature Rise 105 C 105 C 105 C 80 C 105 C 105 C 105 C Tilt Requirements 5 Static 5 Static 5 Static 5 Static 5 Static 5 Static 5 Static Insulation Class H H H H H H H Overload 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. Excitation SE PM PM SE PM PM PM Voltage Construction FW RW FW FW RW FW RW Voltage Regulator CDVR CDVR CDVR CDVR CDVR CDVR CDVR Configuration 1-Brg 1-Brg 1-Brg 1-Brg 1-Brg 1-Brg 1-Brg Coastal Protection Yes Yes Yes Yes Yes Yes Yes Space Heater Yes Yes Yes Yes Yes Yes Yes Short Circuit Current 300%/10 sec. 300%/10 sec. 300%/10 sec. 300%/10 sec. Frame Size C18 OIL FIELD GENERATOR SET PACKAGES DESIGN TO ORDER (60 Hz) Engine Model C18 C18 C18 C18 C18 C18 ekw Rating kva Rating rpm Rated PF Temperature Rise 80 C 90 C 90 C 80 C 90 C 90 C Tilt Requirements 5 Static 5 Static 5 Static 5 Static 5 Static 5 Static Insulation Class H H H H H H Overload 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. 50%/2 min. Excitation SE PM SE SE PMG SE Voltage Voltage Regulator CDVR CDVR CDVR CDVR CDVR CDVR Configuration 1-Brg 1-Brg 1-Brg 1-Brg 1-Brg 1-Brg Coastal Protection Yes Yes Yes Yes Yes Yes Construction RW FW RW RW FW RW Short Circuit Current 300%/10 sec. 300%/10 sec. Optional Generator For the 455, 500, and 545 ekw generator set a 600 volt generator shall be available as SE, without a voltage regulator. The 480 volt generator shall be PM for the same ratings. The SCR optional generator is for drill rig applications and the VFD optional generators are for variable frequency down-hole pump and single-unit drilling. The Multiple VFD generators should be developed if the generator costs do not exceed 5% compared to the single VFD generator development costs. LEHW Page 5 of 8
6 INSTALLATION DRAWINGS Front View Right Side View mm (79.9 in.) mm (71.9 in.) mm (83.3 in.) mm (57.8 in.) mm (60.0 in.) mm (143.0 in.) Note: Package dimensions may change depending on generator arrangement selection. Package Dimensions Length mm in. Width mm 60.0 in. Height mm 83.3 in. Weight (estimated) kg 11,095 lb. Note: Do not use for installation design. See general dimension drawings for detail. RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, AS2789, CSA, EGSA101P, IEC60034, ISO3046, ISO8528, NEMA MG 1-32, UL508, 72/23/EEC, 89/336/EEC, 98/37/EEC. Prime output available with varying load for an unlimited time. Prime power in accordance with ISO percent overload power in accordance with ISO3046, AS2789, and BS5514 available on request. Prime power ambients shown indicate ambient at 100 percent load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1995 standard conditions. These ratings also apply at ISO3046 standard conditions. Fuel rates are based on fuel oil of 35 API [16 C (60 F)] gravity having an LHV of kj/kg (18,390 Btu/lb) when used at 29 C (85 F) and weighing g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements. Consult your Caterpillar representative for details. LEHW Page 6 of 8
7 THIS PAGE INTENTIONALLY LEFT BLANK LEHW Page 7 of 8
8 Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, S O S, ACERT, ADEM, Caterpillar Yellow and the POWER EDGE trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. TMI Reference No.: DM LEHW (5-08) 2008 Caterpillar All rights reserved.
STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts
DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,
How To Use A Cat Diesel Engine
DIESEL GENERATOR SET STANDBY 440 ekw 550 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption
IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,
STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts
DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption
DIESEL GENERATOR SET STANDBY 560 ekw 700 kva Caterpillar is leading the power generation market place with power solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 2500 ekw 3125 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 1500 ekw 1875 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts
DIESEL GENERATOR SET STANDBY 3000 ekw 3750 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and
STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm 11000 Volts
DIESEL FEATURES GENERATOR SET STANDBY 3200 ekw 4000 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched
STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered
RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES
XQ230 SOUND ATTENUATED DUAL VOLTAGE 50/60 Hz Arrangement shown with optional trailer FEATURES EMISSIONS EPA Tier 3 and CARB Emissions Certified for non-road mobile applications at all 60 Hz and 50 Hz ratings
NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts
GAS GENERATOR SET NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts Image shown may not reflect actual package Caterpillar is leading the power generation marketplace with power solutions
C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm
CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression
DIESEL GENERATOR SETS
DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete
3516 Industrial Engine
CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle Diesel Bore...170.0 mm (6.69 in) Stroke...190.0 mm (7.48 in) Displacement... 69.06 L (4,214.3 in 3 ) Aspiration...Turbocharged / Aftercooled Compression Ratio...13.0:1
DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET
DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA
NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS
GAS GENERATOR SET NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS Image shown may not reflect actual package Caterpillar is leading the power generation
GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory
GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer
D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system
4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm
The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance
Spark-ignited generator set
Specification sheet Spark-ignited generator set 30 60 kw standby EPA emissions Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum
Diesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm
Marine Auxiliary Engine SPECIFICATIONS 3304B 56 bkw (75 bhp) 100 mhp @ 1200 rpm Shown with Accessory Equipment I-4, 4-Stroke-Cycle-Diesel Emissions...IMO compliant Displacement... 7.0 L (425 cu. in.) Bore...
XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)
RENTAL Standby Prime Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) Shown with optional trailer FEATURES EPA TIER 4 AND CARB CERTIFIED
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
3516B Offshore Generator Set
3516B Offshore Generator Set 1648 ekw (2060 kva) 1717 bkw (2303 bhp) 50 Hz (1500 rpm) Actual configuration may vary from displayed image CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle-Diesel Emissions...
Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES
C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES Factory designed, certified prototype tested with torsional analysis. Production tested and delivered in a package that is ready
Diesel Generator Set Model DFHC 60 Hz
Diesel Generator Set Model DFHC 60 Hz 900 kw, 1125 kva Standby 818 kw, 1023 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
Diesel Generator Set Model DFMB 60 Hz
Diesel Generator Set Model DFMB 60 Hz 1500 kw, 1875 kva Standby 1250 kw, 1563 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation
Diesel Generator Set Model DGDK 60 Hz
Diesel Generator Set Model DGDK 60 Hz 125 kw, 156 kva Standby 113 kw, 141 kva Prime Description The Cummins Power Generation DG-series commercial generator set is a fully integrated power generation system
3516B Offshore Emergency Generator Set
3516B Offshore Emergency Generator Set 1825 ekw (2281 kva) 1901 bkw (2549 bhp) 60 Hz (1800 rpm) Actual configuration may vary from image shown CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle-Diesel Emissions...
How To Control A Power Command Powerplant
Diesel Generator Set Model DFEJ 60 Hz EPA Emissions 450 kw, 563 kva Standby 410 kw, 513 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power
INDUSTRIAL ENGINE RATINGS GUIDE
INDUSTRIAL ENGINE RATINGS GUIDE Table of Contents Highly Regulated/Lesser Regulated For purposes of this Guide, Highly Regulated refers to engines that meet stringent emission standards in effect in the
CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw
CAT NEXT GENERATION DIESEL GENERATOR SETS C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw THE NEXT GENERATION CAT DIESEL GENERATOR SET FEATURES SEVERAL KEY DESIGN AND PERFORMANCE ENHANCEMENTS TO ITS
Magnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED
1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED Prime Power 400 V, 50 Hz, 1000 KVA (800 ekw) 480 V, 60 Hz, 910 ekw FEATURES
1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.
Diesel Truck Engine 3126B 175-330 hp 420-860 @ 1440 rpm Peak CATERPILLAR ENGINE SPECIFICATIONS 6-Cylinder, 4-Stroke-Cycle Diesel Bore in (mm)... 4.33 (110) Stroke in (mm)... 5.0 (127) Displacement cu in
TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength
TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET
TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,
Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1
K3 WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 31 34 Power kw 31 34 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor
Annex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
Technical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
X G 1 3 5 R E N T A L
CONTINUOUS 135 kw 60 Hz FEATURES Concept model shown with optional chassis Frequency (Hz) Voltage (V) Continuous kw (kva) 60 480/277 135 (169) 60 240/139 135 (169) 60 208/120 135 (169) FUEL/EMISSIONS STRATEGY
Marine Generating Sets 3.7 to 50 kva
Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating
1100 Series 1104C-44TAG2 Diesel Engine ElectropaK 99.5 kwm @ 1500 rpm
Building upon Perkins proven reputation within the power generation industry, the Perkins 1100 Series range of ElectropaK engines now fit even closer to the needs of their customers. With this 1104C-44TAG2
(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS
6BTA5.9 F1 FIRE PUMP ENGINE /-- SPECIFICATIONS Four Stroke Cycle, Turbocharged-Aftercooled, In-Line, 6 Cylinder Diesel Engine LISTED AGENCY RATINGS 182 HP O 1760 RPM 208 HP O 2100 RPM Bore and Stroke 4.02
Atlas Copco Generators
Atlas Copco Generators QIX 15 - QIX 540 16 kva LTP to 549 kva LTP at 50 & 60 Hz The QIX options include Earth leakage relay Qc generating set control panels for all standby and/or paralleling applications
Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:
Standby Generators Liquid-Cooled Gas Engine 1 of 9 INCLUDES: Two Line LCD Tri-Lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System
APS100 Rental Generator Set Specification
BARTONVIE * CEDAR RAPIDS * DAVENPORT * EAST PEORIA * HANNIBA * MOBERY * ROCK FAS * SPRINGFIED * URBANA APS100 Rental Generator Set Specification STANDBY 100 kw 60 Hz/PRIME 90 kw 60 Hz FEATURES EPA TIER
CAT CG132. Series Gas Generator Sets
CAT CG132 Series Gas Generator Sets CAT CG132 SMARTER ENERGY SOLUTIONS COMMERCIAL AND INDUSTRIAL FACILITIES Facilities such as manufacturing plants, resorts, shopping centers, office or residential buildings,
Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8
SILENT PACK AIR-COOLED SINGLE PHASE 60 HZ INT. TIER IV DIESEL Generating Rates SERVICE PRP STANDBY Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power
DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
PM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO
D10 WATER-COOLED THREE PHASE 50 HZ STAGE 2 DIESEL Generating Rates SERVICE PRP STANDBY Power kva 100 107 Power kw 79 86 Rated Speed r.p.m. 1.500 Standard Voltage V 400/230 Available Voltages V 230-230/132
307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights
307E Mini Hydraulic Excavator Bucket Engine Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo Net Power 41.5 kw (55.6 hp) Gross Power @ 2,000 rpm 43 kw (57.6 hp) Weights Operating Weight 6800
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG3A diesel engine Stamford HCI 634 H alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4006-23TAG2A diesel engine Newage/Stamford HCI634G alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
IGSA POWER GENERATION SYSTEMS
IGSA POWER GENERATION SYSTEMS MODEL: GSDD20600S. MTU, 12V1600G80S, 1800 RPM, 60 HZ. CAPACITY KW KVA 600 750 Reference Conditions ISO 3046: Intake air temperature Side altitude above sea level Charge air
AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ
Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at power factor Cos Phi 1
E10 (HIGH SPEED) WATER-COOLED SINGLE PHASE 60 HZ NON COMPLYING EPA DIESEL Generating Rates SERVICE PRP STANDBY Power kva 85 93 Power kw 85 93 Rated Speed r.p.m. 1.800 Standard Voltage V 240/120 Rated at
D6R Series III Track-Type Tractor
D6R Series III Track-Type Tractor Engine Engine Model Cat C9 ACERT Net Power ISO 9249 138 kw 185 hp Engine XL/XW/LGP Net Power ISO 9249 149 kw 200 hp Weights Operating Weight 18 669 kg 41,159 lb Shipping
PI734D - Technical Data Sheet
PI734D - Technical Data Sheet PI734D SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
PI734B - Technical Data Sheet
PI734B - Technical Data Sheet PI734B SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other national and international
OFFSHORE POWER. Caterpillar Global Petroleum
OFFSHORE POWER Caterpillar Global Petroleum YOUR OPERATION, CATERPILLAR SOLUTIONS We listened to our customers, invested in research and development, and put 80 years of engine manufacturing experience
Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM
Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
PI044E - Winding 311 Technical Data Sheet PI044E SPECIFICATIONS & OPTIONS STANDARDS Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
SG080 9.0L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG080 80 kw. Standby Power Rating 80 kw 100 kva 60 Hz
SG080 9.0L Industrial Spark-Ignited Generator Set EPA Certified Stationary Emergency SG080 80 kw Power Rating 80 kw 100 kva 60 Hz Prime Power Rating* 72 kw 90 kva 60 Hz *EPA Certified Prime ratings are
PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS
PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section
New 27 hp 2 Cylinder Liquid-Cooled Engine
New 27 hp 2 Cylinder Liquid-Cooled Engine Introducing the new 27 hp Liquid-Cooled Vanguard 2/LC Engine A cooler, smoother, longer running commercial engine. That s the liquid-cooled advantage of the Vanguard
A Single Source for all Power System Solutions
Power Generation Gas Engine Powered Generating Sets 1540-1750 kwe 50 Hz 1250-1760 kwe 60 Hz QSV91G Series Engines Standard Genset Features Single Source Responsibility Design, manufacture and testing of
3790 en - 06.2007 / d. Alternators LSA 46.2-4 Pole. Electrical and mechanical data
379 en - 6.7 / d Alternators LSA 46.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 46.2 alternator is designed to be suitable for typical generator applications, such
Commercial Marine Generators
Commercial Marine Generators tak e comm a nd You ve got a lot riding on your reputation. A job, a contract, a crew. There s no time to mess with shoddy power. So man up with KOHLER commercial marine generators.
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
LOAD BANK TESTING PROCEDURE
LOAD BANK TESTING PROCEDURE APPENDIX G SPS-G-1 of 9 I. General GENERATOR LOAD BANK TESTING AND ENGINE TESTING A. Provide all equipment, labor, materials and supervision necessary to test the stand-by diesel
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
The 26 200 kva RAnge
The 26 200 kva Range The new 26 200 kva range...designed to Deliver More. We understand the unique needs of generating set customers around the world. Forty years experience combined with the latest technology
Medical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
SD010 2.4L. Industrial Diesel Generator Set. SD010 10 kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.
SD010 2.4L Industrial Diesel Generator Set EPA Certified Stationary Emergency SD010 10 kw 1 of 6 Power Rating 10 kw 12.5 kva 60 Hz Prime Power Rating* 9 kw 11 kva 60 Hz *EPA Certified Prime ratings are
HEAVY-DUTY, REDEFINED. REDEFINED.
HEAVY-DUTY, REDEFINED. TO GET YOUR TOUGHEST JOBS DONE, you need an engine that works even harder than you do. That s why Caterpillar offers the CT13 engine for our vocational trucks. It delivers every
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Integrated Power Systems for Data Centers
Integrated Power Systems for Data Centers A Commitment to Data Centers Caterpillar is committed to providing optimum value to the Data Center industry by leveraging our engineering, manufacturing, distribution,
HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards
UCI274C - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4016TAG2A diesel engine Newage/Stamford PI734F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty
UCI274H - Technical Data Sheet
- Technical Data Sheet SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS000,
CUKUROVA GENERATOR SYSTEMS
Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features AMF, Automatic mains failure unit Heavy
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Power Generation generator sets - 400 kva to 15 MW
Generator s Power Generation Power Generation generator sets - 400 kva to 15 MW MGS B/C/HV diesel range MUG diesel range KU diesel range GSR gas range KU gas range Stand-by, prime power & continuous power
Frequently Asked Questions Generators
Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion