Distribution transformer components Product guide

Size: px
Start display at page:

Download "Distribution transformer components Product guide"

Transcription

1 Distribution transformer components Product guide

2 Bushings ABB offers both high voltage and low voltage bushings designed for use in pad or surface mounted transformers. The bushings insulate the current carrying conductor from the tank, allowing for termination of both the airside conductor and the transformer leads. Both the high and low voltage bushings have been designed to conform with ANSI/IEEE standards. ABB high voltage bushing wells are molded from a glassreinforced, high temperature nylon (HTN) resin. They are designed to mate with all bushing inserts conforming to the appropriate sections of IEEE In addition to the fixed stud bushing well, ABB offers a removable stud version. ABB one inch and five-eighths inch low voltage bushings are molded from a glass-reinforced, high temperature nylon resin. The. inch low voltage bushings are molded from a polyester resin. All of the low voltage bushings provide a spade terminal for internal connection and a threaded stud for external connection. High voltage bushing well options BIL (kv) Continuous current (A) Package quantity Part number Integral copper stud ZUA760-AKC Removable copper stud ZUA760-AKD HV bushing mounting HV bushing well key dimensions reference diameter for the mounting studs tank mounting hole 0. mounting stud * Dimensions are presented in inches Bushings ABB distribution components

3 Low voltage bushing options BIL (kv) Continuous current (A) Package quantity Part number 0.6 copper standard length ZUA760-AFC 0.6 copper extended length ZUA760-AFD.000 copper standard length ZUA760-AGC.000 copper extended length ZUA760-AGD.0 copper with hole C6G04.0 copper with holes C6G07 5/8 inch low voltage bushing key dimensions inch low voltage bushing key dimensions and 5/8 inch low voltage bushing mounting.590 A B. C D.80 reference diameter for the mounting studs.8 tank mounting hole 0. mounting stud Stud style Dimension A Dimension B Standard Extended Stud style Dimension C Dimension D Standard Extended inch low voltage bushing key dimensions and mounting. inch low voltage bushing mounting reference diameter for the mounting studs.80 tank mounting hole 0. mounting stud * Dimensions are presented in inches ABB distribution components Bushings

4 Fuse holders ABB offers two types of fuse holders - the Type K and the DO-III fuse holder. Both fuse holders are designed for use in pad-mounted transformers. The fuse holders are available in a variety of ratings and configurations which are detailed on the next few pages. The ABB DO-III fuse holder is a draw-out, load-break expulsion fuse holder. It is intended to protect the distribution system in the event of an internal transformer fault, secondary fault, or severe overload when used with properly coordinated expulsion fuses. The DO-III fuse holder is designed for use at voltages up to kv (line-to-ground) and kv BIL. The fuse holder works in conjunction with ABB DO-III fuse links which can be found on page 6 of this guide. DO-III fuse holder standard options Vent hole Check valve Cartridge Silver plating Package quantity Part number x x 44 C07G0 x x 44 C07G0 x x x 44 C07G0 x x 44 C07G04 x x x 44 C07G06 x x x 44 C07G07 x x 44 C07G08 x x x x 44 C07G09 x x 44 C07G0 DO-III mounting DO-III fuse holder accessories Description Package quantity Part number Cartridge with end plug 7 B4G0 Silver plated cartridge with end plug 7 B4G0 Puller assembly, cartridge, and end plug 6 C0765G0 Puller assembly 6 C0765G0 Puller assembly, silver plated cartridge, and end plug 6 C0765G0 Mounting nut and gasket 0 C07G05 Drip shield 0 C0880H0 End plug 0 A98H0 Gasket A49H radius mounting index.6 tank mounting hole * Dimensions are presented in inches 4 Fuse holders ABB distribution components

5 The Type K current limiting fuse canister provides an air-insluated receptacle for general purpose current limiting fuses used in pad-mounted or submersible transformers such as the Hi-Tech Trans-Guard FX fuse. The Type K fuse holder features dead front construction, hermetic sealing, self-aligning spring contacts and stainless steel, corrosion-resistant components. Additionally, the canister can be welded or clamped onto the transformer tank. The Type K fuse holder allows the operator easy access to the current limiting fuse for inspection or replacement. The table below provides the maximum fuse dimensions suitable for use in the Type K canister. Voltage class (kv) Maximum diameter A Maximum length B Terminal length C Terminal diameter D C B D A The Type K canister is available in three different voltage classes and is either welded into place or clamped. Type K canister options Voltage (kv) BIL (kv) Package quantity Part number - welded Part number - clamped Type K mounting reference diameter for the mounting studs.80 tank mounting hole 0. x. mounting stud (clamped version only) Type K accessories Description Package quantity Part number Mounting clamp 4 980AH0 Gasket Fuse holder adapter 8. kv to 5.5 kv Fuse holder adapter 8. kv to kv Fuse holder adapter 5.5 kv to kv * Dimensions are presented in inches ABB distribution components Fuse holders 5

6 Fuses Safety, including the protection of people and property, is at the forefront of today s business. Fuses offer a simple and cost effective solution to some of the risk associated with electric distribution. The fuses listed in the next few pages are intended for use under oil in distribution equipment. ABB offers a variety of expulsion fuses. Both ABB protective links and draw-out fuses offer protection to the distribution system should an internal transformer fault occur. ABB s drawout expulsion fuses also offer some protection for overload and secondary faults. Isolation links, though not true fuses with an interrupting rating, are used to protect those who work on transformers from connecting into a faulted circuit. ABB draw-out fuses are designed for use in ABB s DOIII type fuse holder, but are interchangeable with most draw-out fuse holders on the market today. These fuses are available in three different configurations for a wide array of current ratings. The draw-out fuses are generally limited to 4.94 kv line-to-line grounded Y. However, when paired with a current limiting fuse the voltage rating can be extended slightly. ABB isolation links are not fuses in the sense that they are not designed to interupt current. However, isolation links are intended to be used in conjunction with draw-out expulsion fuses to prevent the unintentional re-energization of a faulted transformer. In the table below use the current rating and fuse type to locate the needed draw-out expulsion fuse and associated isolation link part numbers in the right two columns. Draw-out fuses Current rating (Amperes) Fuse type Package quantity Draw-out fuse part number Optional isolation link part number 6 current sensing 0 B4G04 C0G0 0 current sensing 0 B4G06 C0G0 5 current sensing 0 B4G08 C0G0 current sensing 0 B4G0 C0G0 40 current sensing 0 B4G C0G0 65 current sensing 0 B4G4 C0G05 current sensing 0 B4G6 C0G05 40 current sensing 0 B4G7 C0G05 dual sensing 0 B44G0 C0G0 8 dual sensing 0 B44G05 C0G0 5 dual sensing 0 B44G08 C0G0 dual sensing 0 B44G0 C0G05 dual sensing 0 B44G C0G06 65 dual sensing 0 B44G4 C0G07 5 dual element 0 B45G0 C0G0 6 dual element 0 B45G04 C0G0 8 dual element 0 B45G05 C0G0 dual element 0 B45G06 C0G0 5 dual element 0 B45G07 C0G0 dual element 0 B45G09 C0G0 40 dual element 0 B45G C0G0 dual element 0 B45G C0G0 6 Fuses ABB distribution components

7 The ABB protective link is an oil-immersed, expulsion type fuse designed for use in the high voltage circuit of distribution equipment. Protective links are available in a variety of fuse sizes and voltage ranges up to 4.5 kv line-to-line grounded Y. In most applications today, the protective link is used in series with a partial range or back-up current limiting fuse such as the Hi-Tech Trans-Guard family of current limiting fuses. The standard offering for the 5 kv protective link featured below includes a long lead. This product is also offered with a short lead or for block mounting. Please contact ABB for details. Protective links Current rating (Amperes) Fuse curve Package quantity Part number through 5 kv Part number through kv Part number through 4.5 kv B58G0 779C667G0 45B995G B58G0 779C667G0 45B995G9 7 A 0 59B58G 779C667G0 45B995G B58G06 779C667G08 45B995G B58G0 779C667G04 45B995G 5A 0 59B58G 779C667G09 45B995G B58G04 779C667G05 45B995G B58G05 779C667G06 45B995G 4 7A 0 59B58G 779C667G 45B995G B58G07 779C667G07 45B995G B58G08 779C667G4 45B995G B58G09 779C667G5 45B995G B58G4 779C667G6 45B995G B58G Not available Not available B58G Not available Not available ABB distribution components Fuses 7

8 Switches ABB distribution transformer tap changers and dual voltage switches are de-energized, rotary type switches suitable for use in both pole and pad-mounted transformers. Tap changers are available that can handle up to 00 kv BIL and amps, while dual voltage switches are available that can handle up to kv BIL and amps. The switches are configurable with many options including the number of decks, termination choices, handle styles, and dial plate designations. These switches were designed and tested in accordance with IEEE standard C ABB distribution tap changers and dual voltage switches feature a wide range of configurations. To select a standard switch, please refer to the following tables and locate the appropriate ratings and requirements. For other configurations not listed in these tables, please contact your ABB representative. Dual voltage (DV) Number of decks Current rating (Amperes) Stationary contacts description Moving contact description Package quantity DV switch part number #-0 Crimp short 609C76G05 #-0 Crimp 0 609C76G09 #-0 Crimp C76G5 #-0 Crimp C76G6 0. bolt hole C76G 0. bolt hole C76G stud C76G stud C76G08 #-0 Crimp short 609C77G09 #-0 Crimp 0 609C77G05 #-0 Crimp C77G5 #-0 Crimp C77G6 0. bolt hole C77G 0. bolt hole C77G stud C77G stud C77G08 #-0 Crimp short 609C8G #-0 Crimp 0 609C8G05 #-0 Crimp C8G5 #-0 Crimp C8G6 0. bolt hole C8G08 0. bolt hole C8G stud C8G stud C8G09 8 Switches ABB distribution components

9 Tap changer (TC) Number of decks Current rating (Amperes) Stationary contacts description Moving contact description Package quantity TC switch part number #-0 Crimp short Wiping C0G0 #-0 Crimp 0 Wiping C0G0 #-0 Crimp 45 Wiping C0G0 #-0 Crimp 90 Wiping C0G04 0. bolt hole CG 0. bolt hole CG stud CG stud CG08 #-0 Crimp short 609C7G09 #-0 Crimp 0 609C7G8 #-0 Crimp C7G5 #-0 Crimp C7G6 0. bolt hole C7G 0. bolt hole C7G stud C7G stud C7G4 #-0 Crimp short 609C78G #-0 Crimp 0 609C78G05 #-0 Crimp C78G5 #-0 Crimp C78G6 0. bolt hole C78G09 0. bolt hole C78G stud C78G stud C78G De-Energized switch mounting 45 terminal angle. tank mounting hole Decks 90 terminal angle 0.4 radius mounting index Terminal angle options Decks 0 terminal angle 0 * Dimensions are presented in inches Deck ABB distribution components Switches 9

10 Switches The ABB LBOR-II switch is a manually operated, two position, load make or break, oil immersed, rotary switch. It is designed for use with distribution transformers (pad-mounted or submersible) and self contained distribution switchgear. With a smaller mounting envelope than most switches on the market today, the LBOR-II switch has been designed to save you money. The reduced envelope allows for smaller equipment that requires less oil and steel to manufacture. ABB LBOR II switches feature a wide range of configurations. To select a switch, please refer to the tables below and locate the appropriate ratings, then select a style number for the required mounting configuration. If interlock kits are required for a nut mount switch, please order the suitable style without and add the interlock kit, style A949G0. For non-standard configuration options that are not listed in these tables, please contact your ABB representative. LBOR-II ordering information One deck Style numbers Continuous current (A) BIL (kv) Maximum voltage (L-G kv) Mounting orientation Weld-in without Weld-in with standard Weld-in with interlock Nut mounting with Nut mounting without Wall 7D94G0 7D94G 7D94G4 L095NC00 L095JC Wall/Cover 7D9G0 7D9G 7D9G4 LNC00 LJC Wall/Cover 7D9G0 7D9G 7D9G4 LNC400 LJC400 Two deck Style numbers Continuous Current (A) BIL (kv) Maximum voltage (L-G kv) Mounting orientation Weld-in without Weld-in with standard Weld-in with interlock Nut mounting with Nut mounting without Wall 7D94G0 7D94G 7D94G5 L095NC00 L095JC Wall/Cover 7D9G0 7D9G 7D9G5 LNC00 LJC Wall/Cover 7D9G0 7D9G 7D9G5 LNC400 LJC400 Three deck Style numbers Continuous current (A) BIL (kv) Maximum voltage (L-L kv) Mounting orientation Weld-in without Weld-in with standard Weld-in with interlock Nut mounting with Nut mounting without Grd-Y Wall 7D94G0 7D94G 7D94G6 L095NC00 L095JC00 00 * 8 Grd-Y Wall/Cover 7D9G0 7D9G 7D9G6 LNC00 LJC * 7 Grd-Y Wall/Cover 7D9G0 7D9G 7D9G6 LNC400 LJC400 * Per IEC 65- the BIL rating for these styles is 80 kv 0 Switches ABB distribution components

11 LBOR nut mounting LBOR weld-in mounting. tank mounting hole.00 Mounting surface for A frame must be clear from obstruction 0.4 radius mounting index.06 tank mounting hole.8 Mounting boss with retained gasket Mounting nut Mounting bolts Mounting boss Operating handle Tank wall Cantilever feet Operating handle Spirol pin Tank wall A frame mounting bracket * Dimensions are presented in inches ABB distribution components Switches

12 Contact us ABB Inc. South Cavalier Drive Alamo, Tennessee 800, USA Phone: Fax: Note: The information contained in this document is for general information purposes only. While ABB strives to keep the information up to date and correct, it makes no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the information, products, services, or related graphics contained in the document for any purpose. Any reliance placed on such information is therefore strictly at your own risk. ABB reserves the right to discontinue any product or service at any time. ZUA Copyright 05 ABB. All rights reserved.

Type K current limiting fuse canister Technical information and installation guide

Type K current limiting fuse canister Technical information and installation guide Transformer components Type K current limiting fuse canister Technical information and installation guide The Type K current limiting fuse canister provides an air-insulated receptacle for general-purpose

More information

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F OVR Three-Phase Recloser and PCD Control Style Guide 1VAL264001-SG October 13, 2009 Revision F The OVR three-phase recloser style guide aids in the proper selection of your OVR three-phase style number.

More information

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP

More information

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014) 1.0 GENERAL S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014) 1.1 This specification covers the electrical and mechanical characteristics of Three-Phase,

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd ACTOM OUTDOOR DISCONNECTORS Single Side Break (SSB) Disconnector 22-132 kv, 800-1 A, 25 ka - 3s Typical bearing assembly. Voltage range 11 kv to 132

More information

Issued 06-01-07 E.C.S. Section WTR00 INFORMATION SECTION Page 1 of 1

Issued 06-01-07 E.C.S. Section WTR00 INFORMATION SECTION Page 1 of 1 Issued 06-01-07 E.C.S. Section WTR00 INFORMATION SECTION Page 1 of 1 INDEX SECTION WTR01: ELECTRICAL CONNECTIONS PRIMARY.. Page 1 SERVICE DROPS FROM THREE-PHASE TRANSFORMER BANKS.. Page 9 SECTION WTR02:

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal

More information

1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

1ZSC000563-AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide 1ZSC000563-AAC en, Rev. 7 Resin impregnated paper bushing, oil to air, type GSB Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

Primary and Secondary Electrical Distribution Systems

Primary and Secondary Electrical Distribution Systems Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility

More information

Transformer Bushings for GIS

Transformer Bushings for GIS Transformer Bushings for GIS Oil to SF6 Connections GARIP RTKG 725-55 kv SQS certified ISO 91 / ISO 141 Bushings RIP - Technology for SF6 / Oil - Bushings In modern metal enclosed switchgear SF6 -gas is

More information

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal. www.takfanmakina.com.tr

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal. www.takfanmakina.com.tr www.takfanmakina.com.tr Plug in Bushing LV Monoblock RMU Bushing 4 Way CT Terminal Solution Partner of Medium Voltage Insulation and Epoxy Casting Design *Medium voltage Switching Equipments Design *Load

More information

Instructions for Secondary Unit Substation Transformers 150-3000 KVA, Three Phase

Instructions for Secondary Unit Substation Transformers 150-3000 KVA, Three Phase ABB Inc. Instruction Booklet Distribution Transformers Jefferson City, MO ISO 9001 Certified I.B. 46-060-1, Section E ILUJ000004-BLE Effective: January, 2008 Instructions for Secondary Unit Substation

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

MDT5N25 & MTD5N40 SERVICE PARTS

MDT5N25 & MTD5N40 SERVICE PARTS MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts

More information

Step Voltage Regulators

Step Voltage Regulators Step Voltage Regulators Don Wareham Field Application Engineer Today s Agenda Introduction Voltage Regulator theory Voltage Regulator application considerations Installation and proper bypassing Wrap-up/questions

More information

1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

1ZSE 2750-105 en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide 1ZSE 2750-105 en, Rev. 8 Transformer bushings, type GOE and GOE(2) Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible

More information

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) August, 2009 Vertical Break Parallel (VBP) / Vertical Break Slant (VBS) Type VBPA (Aluminum) / Type VBPC (Copper) Type VBSA (Aluminum) / Type VBSC (Copper) PASCOR Air Break Switch Technology PASCOR offers

More information

CAUTION. 4. Cable Connections DANGER WARNING CAUTION. 3. Bushing Components

CAUTION. 4. Cable Connections DANGER WARNING CAUTION. 3. Bushing Components Instruction Manual for POC Bushings 1. Scope This instruction contains general procedures to be followed during receiving, installation, storage and maintenance of all PCORE POC bushings. This instruction

More information

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers Specification Guide for RVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards...3 3.0 Supplier Qualifications...4 4.0 Circuit Breaker Element

More information

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13 Cable Accessories for Extruded Dielectric Cable 69kV - 230kV Rated Components used in cable systems 100% Tested Factory Molded For outdoor applications through 230kV For gas insulated substations and transformers

More information

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Masterclad Medium Voltage Passive Arc-Resistant Switchgear Masterclad Medium Voltage Passive Arc-Resistant Switchgear Square D Masterclad medium voltage passive arc-resistant (AR) switchgear is designed with utilities and industrial customers in mind who demand

More information

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions Instructions Instructions The Parts in this section of the manual are listed by Item Number, Part Number, Description and Quantity. The Item Numbers are in a circle with an arrow pointing to the specific

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold 41-759.3C 41-759.3C the magnetic core upon energizing of the switch. When the switch closes, the moving contacts bridge two stationary contacts, completing the trip circuit. Also during this operation two fingers

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC Project name: Customer: Address, location of the system: Serial number

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable

More information

FASTON Terminals and Connectors

FASTON Terminals and Connectors Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This

More information

Type NT and Type ZWM Terminal Blocks

Type NT and Type ZWM Terminal Blocks Type NT and Type ZWM Terminal Blocks Side view of closed Sliding Link Block Sliding Link Block with white marker strip Unit-pole construction Sliding link to permit testing without disturbing wiring High

More information

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Customer Substation Manual 08/05/02

Customer Substation Manual 08/05/02 Customer Substation Manual Table of Contents Section Page 2 of 85 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation

More information

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety

01.4IB.51200B PowlVac-AR Arc Resistant Switchgear. 5kV & 15kV 1200A, 2000A, 3000A, & 4000A Forced Cooled. Powered by Safety PowlVac-AR Arc Resistant Switchgear 1200A, 2000A, 3000A, & 4000A Forced Cooled Powered by Safety PowlVac-AR Arc Resistant Switchgear 01.4IB.51200B Contact Information Powell Electrical Systems, Inc. www.powellind.com

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker

More information

Bypass switches. Type B-1 and type B-2. Answers for energy.

Bypass switches. Type B-1 and type B-2. Answers for energy. Bypass switches Type B-1 and type B-2 Answers for energy. Eliminate voltage regulator bypass switch problems with type B-1 and type B-2 Overview Type B-1 The Bridges Electric type B-1 regulator bypass

More information

Type MG-6 Multi-Contact Auxiliary Relay

Type MG-6 Multi-Contact Auxiliary Relay Type MG-6 Multi-Contact Auxiliary Relay Instruction Leaflet: 41-753.1 N Effective: August 2008 Supersedes 41-753.1 M, Dated December 1999 ( ) Denotes Change Since Previous Issue Device Number: 94X, Y,

More information

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general

More information

Chapter 5 FLOOR LOADING AND WEIGHTS

Chapter 5 FLOOR LOADING AND WEIGHTS Chapter 5 FLOOR LOADING AND WEIGHTS Section 1.0 Floor Loading Section 2.0 Seismic Data The CT system has a total floor load of approximately 6660 lbs (3021 kg). About 5050 lbs (2291 kg), including patient

More information

POLE MOUNT SYSTEM EX-3 INSTALLATION

POLE MOUNT SYSTEM EX-3 INSTALLATION May 2014 POLE MOUNT SYSTEM EX-3 INSTALLATION The Pole Mount System EX-3 is an easy to install and flexible system designed to allow ONE SYSTEMS loudspeaker systems to be mounted to pole structures. The

More information

261000 Medium Voltage Electrical Distribution

261000 Medium Voltage Electrical Distribution Sections Included In This Standard: 1.1 General 1.2 Underground Cable 1.3 Medium Voltage Switches 1.4 Transformers 1.5 Electrical Manholes 1.6 Switch Vaults 1.7 Distribution Switchgear/Switchboards This

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE. SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION

More information

Fuseology. Medium Voltage Fuses. Continuous Current-Carrying Capacity. General. Interrupting Rating. Additional Rules.

Fuseology. Medium Voltage Fuses. Continuous Current-Carrying Capacity. General. Interrupting Rating. Additional Rules. Fuseology Medium Voltage Fuses General Fuses above are classified under one of three classifications as defined in ANSI/IEEE C37.40. 1. General Purpose Current-Limiting Fuse: A fuse capable of interrupting

More information

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic

More information

Quick Reference Guide Euro Style Terminal Blocks

Quick Reference Guide Euro Style Terminal Blocks Quick Reference Guide Euro Style terminal block connectors feature various wire termination methods including rising cage clamp, wire protector, spring, IDC and crimp snap. The design of terminal block

More information

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation Medium Voltage (MV) & High Voltage (HV) Training Module 6 Date of the presentation Electrical System Basics MV vs. HV - Definitions Differences between USA and the rest of the world IEC define a high voltage

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

36T Series Snap-Action Temperature Controls

36T Series Snap-Action Temperature Controls 36T Series Snap-Action Temperature Controls Snap-Action Temperature Control The 36T series of 1/2 bimetal temperature controls from Therm-O-Disc offers proven reliability in a compact, versatile, cost-effective

More information

ELECTRONICS G H I J K L M

ELECTRONICS G H I J K L M ELECTRONICS TM LASER INSTALLATION INSTRUCTIONS PARTS KIT Parts Kit includes the following: A- (1) Universal Mounting Bracket A B- (1) Red L.E.D. Laser Alert Light C- (1) Piezo Beeper w/ O Ring Tape D-

More information

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Andersen Electric Window Opener for Andersen Awning and Roof Windows W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of

More information

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8

More information

Low Voltage Switchboards The Best Technical Solution for Your Ship

Low Voltage Switchboards The Best Technical Solution for Your Ship The Best Technical Solution for Your Ship Wärtsilä SAM Electronics Optimal Power Distribution The uninterrupted supply of power to systems and consumers onboard modern ships is an extremly important matter.

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

WINDING RESISTANCE TESTING

WINDING RESISTANCE TESTING WINDING RESISTANCE TESTING WINDING RESISTANCE TEST SET, MODEL WRT-100 ADWEL INTERNATIONAL LTD. 60 Ironside Crescent, Unit 9 Scarborough, Ontario, Canada M1X 1G4 Telephone: (416) 321-1988 Fax: (416) 321-1991

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator The Janus Pantheon mini operator does not typically require the provision of any additional site requirements other than

More information

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form 3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO

More information

Co-location Interconnect Power Panel (CIPP) Installation Guide

Co-location Interconnect Power Panel (CIPP) Installation Guide Co-location Interconnect Power Panel (CIPP) Installation Guide Document INS-97xxxxxxx This guide covers the following part numbers- Trimm 97xxxxxxx Series Table of Contents Section 1 - General Information...

More information

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS

SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS PRIMARY METER POLE ELECTRIC SYSTEM BULLETIN No. 753 JUNE 1993, 2 ND PRINTING APRIL 2002 (Supersedes issue dated March 1983 and incorporates Nov.

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

VE13P-EU. Model: VE13. Lista Części Polish

VE13P-EU. Model: VE13. Lista Części Polish Model: VE13 Lista Części Polish Spis Treści Handle 3 Base 5 Wiring - Wear and Tear parts 7 DF100-A Foam Generator art no. 50000055 9 RECOMMENDED SPARE PARTS 13 Handle VE02 3 Handle VE02 4 Poz Numer katalogowy

More information

DYNA RIDER FOOTBOARD KIT

DYNA RIDER FOOTBOARD KIT -J0 REV. 0-0-0 DYNA RIDER FOOTBOARD KIT GENERAL Kit Number 000 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English

More information

Power Supply Cables and Connectors

Power Supply Cables and Connectors Power Supply Cables and Connectors Often during the excitement of designing a challenging new system, some of the more mundane engineering aspects get overlooked. This is especially true of connections

More information

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS

Safetran TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS I-1-1. Relays SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS Safetran I-1-1 TYPE ST1 AND ST2 VITAL PLUG-IN RELAYS SIZE 1 AND SIZE 2 READILY MOUNTS TO EXISTING SOCKETS ALL FERROUS METAL PARTS ARE NICKEL PLATED MEETS OR EXCEEDS APPLICABLE AREMA RECOMMENDED PRACTICES

More information

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service

More information

Type MOST oil switch. Technical Data 285-20. Contents. Effective October 2013 Supersedes March 2000

Type MOST oil switch. Technical Data 285-20. Contents. Effective October 2013 Supersedes March 2000 echnical Data 285-20 Supersedes March 2000 ype MOS oil switch Contents Description Page General...2 Ordering information....2 Features and detailed description.... 6 Fuse assemblies....7 MOS switching

More information

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks TITAN pt. no.: 03 0000 0120 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

Distribution Voltage Regulators

Distribution Voltage Regulators Distribution Voltage Regulators Type JFR Single Phase 2.5 to 19.9 kv Type SFR Three Phase 13.2 to 34.5 kv Power Transmission & Distribution Siemens JFR & SFR Voltage Regulators Improving Quality of Service

More information

TEGAM Test Leads Work With Most Manufacturers Four-wire Ohmmeters

TEGAM Test Leads Work With Most Manufacturers Four-wire Ohmmeters TEGAM Test Leads Work With Most Manufacturers Four-wire Ohmmeters INTRODUCTION Precision measurements require accurate, reliable connections all the way to the device under test. TEGAM manufactures precision

More information

IRRIGATION PUMPING Table of Contents - Section 900

IRRIGATION PUMPING Table of Contents - Section 900 IRRIGATION PUMPING Table of Contents - Section 900 PARAGRAPH 900.1 GENERAL 1 900.2 METERING REQUIREMENTS 1 900.3 CUSTOMER S CONTROL EQUIPMENT 2 900.4 SERVICE CONDUCTOR REQUIREMENTS 2 900.5 RECOMMENDATIONS

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended

More information

This section applies to the design and installation of transformers.

This section applies to the design and installation of transformers. ELECTRICAL: TRANSFORMERS BASIS OF DESIGN This section applies to the design and installation of transformers. Design Criteria 13.8-kV equipment shall be 15-kV class. Coordinate with short-circuit studies

More information

16300 MEDIUM VOLTAGE DISTRIBUTION

16300 MEDIUM VOLTAGE DISTRIBUTION 16300 MEDIUM VOLTAGE PART 1: GENERAL 1.01 SYSTEM DESCRIPTION A. Most new loads will be served from the underground electric distribution system. This system is a primary open loop configuration served

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054

with installation dynafact boost GAUGE this manual is for use with systems 64050-64054 owners manual with installation instructions dynafact boost GAUGE this manual is for use with systems 64050-64054 GENERAL INSTALLATION PRACTICES This manual is an installation guide for all 1. Banks DynaFact

More information

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

Kuhlman Electric Corporation. 25000 Volt Instrument Transformers

Kuhlman Electric Corporation. 25000 Volt Instrument Transformers Kuhlman Electric Corporation 25000 Volt Instrument Transformers 25000 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y Burden (High Accuracy available) PTT-150-9710(H) 3-4 Wound, Oil-Filled

More information

Toroidal Conductivity Sensor

Toroidal Conductivity Sensor Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16465 PAGE 1 SECTION 16465

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16465 PAGE 1 SECTION 16465 KNOXVILLE, TENNESSEE SECTION 16465 PAGE 1 SECTION 16465 PART 1 - GENERAL 1.01 The switchgear shall be in accordance with the one-line diagram, and shall conform to the following specification. 1.02 The

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER. Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the

More information

QT Residential Blower Metal Residential Blower

QT Residential Blower Metal Residential Blower TROUBLESHOOTING HANDBOOK QT Residential Blower Metal Residential Blower Blower Basics Polaris aboveground, residential blowers are specially designed for installation in noise-sensitive environments. All

More information