PELLET BURNING BOILERS
|
|
- Julianna Newton
- 7 years ago
- Views:
Transcription
1 5
2 PEET BURNING BOIERS 7 models with power capacities from 18 to 45 kw kw 18 kw 24 kw 32,3 kw 29/45 OTTAWA - CAGARY ATANTA - ORANDO EK Heat in continuous evolution The eonardo system automatically controls pellet combustion. It continuously detects the main parameters of combustion, affected by: shape, diameter, etc.) atmospheric pressure, high altitude installation, etc.) ness, humidity level, etc.) and acts accordingly to ensure optimal performance and fuel savings. Innovative ceramic combustor with catalyst unit that increases the combustion temperature, ensuring high efficiency while significantly reducing emissions. The Domoklima control unit allows for automatically controlling the devices and components of the home s heating systems, both at low (floor panels) and high (radiators) temperatures.
3 TOP INE PEET BURNING BOIERS 18 kw Compact pellet boiler of medium-power and small size. Features: System for the automatic control of pellet combustion kitchens through the use of dedicated optional accessories. Optional - with feed screw: 250 kg 500 kg (kit available to increase the capacity up to 800 kg) - with pneumatic feed (silo with a variable capacities): from 2.1 to 3.2 t A Pellet hopper / B Pellet feed screw / C Feed screw gear motor / D Combustion chamber / E Ignition electrical resistance / F Centrifugal fan / G H I External air inlet Ø 50 mm / Smoke outlet Ø 80 mm / Closed expansion tank / Synoptic panel / A B I D E C G H kw kg/h m 3 cm F x64x126h
4 TECHNICA DATA / A Ø 50 mm F Ø 80 mm Vs ½ MF C ½ M 11, ,5 37 Sc M ¾ M 5 16 R ¾ M OTTAWA - ATANTA CAGARY - ORANDO Ø 100 mm F Ø 100 mm 4,5 4, ,5 F 66 4 AFS ½ M R ¾ M Vs ½ F M ¾ M Vs ½ F 7,5 9 8,5 ACS ½ M 10 11, ,5 22 C ½ M S C ¾ M M 1 M R 1 M A: Air / F: Fumes / Vs: Safety valve / M: Delivery / R: Return / C: Boiler load Sc: Boiler discharge AFS: Cold sanitary water ACS: Hot sanitary water
5 TECHNICA DATA / Basic Ottawa Atlanta Calgary** Orlando** EK 29 EK 45 xpxh cm / 60x64x126 63x89x126 63x89x126 66x91x126,5 66x91x126,5 62x98x144 75x129x163 Kg Pellet hopper / externo 65/250/450 kw , , kw min - max 6,1-18 7,5-24 9,5-32,3 7,5-24 9,5-32,3 8-29,5-45 Kg/h min - max Consumption / 1-4 1,7-5,7 2,1-7,35 1,7-5,7 2,1-7,35 2-6,8 3,7- h min - max Autonomy / % m 3 *Heatable volume / Efficienty / 92, ,7 92, ,7 92, ,2 91 mm Smoke outlet / Kg Weight with packaging / 80 M 100 M 100 M Sistema eonardo (S) - 3C Sistem(3C) - Domoklima (DK) S S -3C 3C - DK Fire control: Automatic combustion control / Autoclean: Automatic combustion chamber cleaning / Remote control / Ôçëåêïíôñüë Synoptic panel / GSM Remote management / Confort clima: Shutdown when temperature is reached optional Weekly time programmer / Water capacity / Hearth / ÈÜëáìïò êáýóçò Acero-fundición áôóüëé-ìáíôýìé Incorporated pressure relief valve and expansion tank/ RS 15/6.7 Incorporated kit for hot sanitary water production /
BIOHOUSING Seminar Success stories of biomass heating in small scale
BIOHOUSING Seminar Success stories of biomass heating in small scale Pellet stove: attractive and fully automatic central heating systems Lorenzo Corbella 28th October 2008 House of Cities, Municipalities
More informationHeating with wood chips and pellets
YOUR RELIABLE PARTNER Heating with wood chips and pellets Present on the market 110 for over years 90-150 Advantages of the HERZ firematic boiler User friendly with: Easy operation Automatic cleaning system
More informationPELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
More informationHIGH QUALITY COMPONENTS
Eco reen Line HIGH QUALITY COMPONENTS that distinguish Eco reen Line series of devices 1. The lambda probe it performs a function of an oxygen sensor (O ) in the exhaust gasses, providing constant diagnostic
More informationUNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
More informationBLASTING SYSTEMS. Turbine blasting systems. Air blasting systems. Automatic Painting plants
BLASTING SYSTEMS Turbine blasting systems Air blasting systems Automatic Painting plants 1, Dust Collector 2, Cyclone Separator 3, Sand (shot) Storage Hopper 4, Bucket elevator 5, Primary separator 6,
More informationHAPERO BALANCE / FLASH. 15 kw / 25 kw / 35 kw. Basement Floor Living room ENERGIETECHNIK GMBH PLUG INSTITUT FÜR BRANDSCHUTZTECHNIK
HAERO ENERGIETECHNIK GMBH LUG & C E R T I F I C A T E FOR MECHANISM & SOFTWARE DESIGN F I R E L U G A N D F I R E. E U INSTITUT FÜR BRANDSCHUTZTECHNIK BALANCE / FLASH 15 kw / 25 kw / 35 kw Basement Floor
More informationFLASH TANK ECONOMIZER PRODUCT GUIDE
FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.
More informationHalf the cost Half the carbon
Half the cost Half the carbon the world s most efficient micro-chp What is BlueGEN? The most efficient small-scale electricity generator BlueGEN uses natural gas from the grid to generate electricity within
More information1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationONE STAGE LIGHT OIL AND KEROSENE BURNERS
ONE STAGE LIGHT OIL AND KEROSENE BURNERS RDB SERIES RDB-R 6,8 4,6 kw RDB-R 4, 46, kw RDB.-.R, 4, kw RDB.-.R,, kw RDB,6 68,7 kw RDB. 4,, kw RDB4,7, kw The Riello RDB series of one stage light oil and kerosene
More informationElectric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
More informationINNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
More informationAludesign K A T A L O G
Aludesign K A T A L O G plynové radiátory DESIGN The result of lengthy experience and technological research, GAZELLE TECHNO today is a universally recognised gas radiator*. It has been completely re-designed
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R8216470-01EN - Edition 01-26/10/2009
Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model R8216470-01EN - Edition 01-26/10/2009 Boilers CUENOD Renewable 3121488 12 EAA1...... 3124527 25
More informationNilfisk-ALTO NEPTUNE 3 WHY COMPROMISE. Superior hot water technology and performance
Nilfisk-ALTO NEPTUNE 3 WHY COMPROMISE Superior hot water technology and performance LEADING EDGE HOT WATER PERFORMANCE AND VALUE For the simplest hot water cleaning tasks, be sure to investigate the Nilfisk-ALTO
More informationPorcia, 20 novembre 2012
1 2 PLZ RANGE 14-18-20 3 TECHNICAL NUMBERS 4 MAIN COMPONENTS CONTROL SAFETY HYDRONIC OUTLET WATER TEMPERATURE INLET WATER TEMPERATURE AIR OR WATER EXTERNAL TEMPERATURE FRESH AIR WITH PRESSURE DIFFERENTIAL
More informationwww.optimumheat.co.uk
The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions
More informationMICRO-COGENERATION AND DESALINATION USING ROTARY STEAM ENGINE (RSE) TECHNOLOGY
MICRO-COGENERATION AND DESALINATION USING ROTARY STEAM ENGINE (RSE) TECHNOLOGY Kari Alanne, Kari Saari, Maunu Kuosa, Md. Mizanur Rahman* Andrew Martin** Heikki Pohjola*** *Aalto University, Espoo, Finland
More informationHEAT INTERFACE UNITS (Modular)
HEAT INTERFACE UNITS The Rhico T Fire Modular is probably the most versatile HIU available, the basic unit is a indirect heating only module incorporating a circulation pump on the secondary circuit. (A
More informationCurrent state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:
Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs Layout of the plant Index:
More information1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
More informationSolar Hot Water Heaters
Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless
More informationTechnical specifications. Containerized data centre NTR CDC 40f+
Technical specifications Containerized data centre NTR CDC 40f+ CONTENT 1 THE PURPOSE OF CDC... 3 2 BASIC PROPERTIES... 4 2.1 EXTERNAL DIMENSIONS... 4 2.2 INSTALLATION REQIREMENTS... 4 2.3 ELECTRICAL CONNECTION
More informationKompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
More informationDrying of Woody Biomass. Process Engineering / GEA Barr-Rosin
Drying of Woody Biomass BioPro Expo & Marketplace / Atlanta, GA / March 14-16, 2011 Drying of Woody Biomass Conventional Direct Fired Dryer Technology Proprietary work of the Copyright Owner Issues with
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationUDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
More informationSTOVE-BOILER FOR SOLID FUELS Directions for use and assembling
STOVE-BOILER FOR SOLID FUELS Directions for use and assembling Sadrºaj 1 Technical data 2 1.1 Boiler properties TEMY PLUS P 25............................. 3 1.2 On Product............................................
More informationStove-boiler for solid fuels 12-30 KW Directions for use and assembling
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................
More informationLightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions
Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by
More informationLAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
More informationBiomass heating: a guide to small log and wood pellet systems
Biomass heating: a guide to small log and wood pellet systems Introducing small and batch fed systems Types of biomass boilers Wood stoves Pellet stoves and boilers Log boilers Introducing small and batch
More informationItho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationSpecifications IDROFOX
Specifications IDROFOX Dear Sir or Madam, thank you for choosing our Idrofox stove. Before using your stove, please read this booklet carefully: it explains how to exploit all its features to the full
More informationTechnical Specification. Generating Set with Waukesha engine burning natural gas
Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the
More informationCooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationFactory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
More informationBB-18 Black Body High Vacuum System Technical Description
BB-18 Black Body High Vacuum System Technical Description The BB-18 Black Body is versatile and is programmed for use as a fixed cold target at 80 K or variable target, at 80 K- 350 K no extra cost. The
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationTorino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district
PLANT TORINO NORD Iren Energia is the company in the Iren Group whose core businesses are the production and distribution of electricity, the production and distribution of thermal energy for district
More informationEcological heat. Thermo-Fireplaces. Frascel / Marix / Panoramico / Termocompact / Termocompac Kit Idro. Made in Italy
Ecological heat Thermo-Fireplaces Frascel / Marix / Panoramico / Termocompact / Termocompac Kit Idro Made in Italy Catalog v.2 2014 Ecological heat Pasqualicchio is ISO 9001 European Quality System Certified
More informationNOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS
RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT
More informationTitan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.
IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation
More informationScrew Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
More informationHigh Output Boiler Systems
High Output Boiler Systems Information for Dual System Link up methods For use in GB & IE (Great Britain and Republic of Ireland). This appliance has been certified for use in countries other than those
More informationPE1 Pellet. PE1 Pellet. Pellet boiler. PE1 Pellet. www.froeling.com
PE1 Pellet PE1 Pellet Pellet boiler PE1 Pellet www.froeling.com 1 Heating with pellets For more than 50 years Froling has specialised in the efficient use of wood as a source of energy. Today the name
More informationwww.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationBoiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
More informationReverse combustion log-fired boiler CBI-II / CBB 15 E. User Guide 300019729-001-C
EN Reverse combustion log-fired boiler CBI-II / CBB 15 E User Guide 300019729-001-C . Contents 1 Used symbols...........................................................................3 2 Important recommendations...............................................................3
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationLaddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationTECHNICAL DESCRIPTION
FIREPLACES, STOVES AND FIREBOXES TO BUILD IN (WITHOUT FORCED VENTILATION AND WATER HEAT EXCHANGER) TECHNICAL DESCRIPTION The fireplaces of Prity are intended for heating of private houses and public premises
More informationKompressoren. Oil Water Separators OWS
Kompressoren Oil Water Separators OWS Removal Of Contaminants in Compressed Air Condensate. Atmospheric air contains large amounts of water vapour and dust particles. These contaminants are mixed with
More informationCoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
More informationEffect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer
Effect of Self- Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer Shinsuke Iijima 1, Katsuya Nakayama 1, Koichi Ushiroebisu 1 Mitsuhiro Kubota 2 and Hitoki Matsuda 2 1. Engineering Division,
More informationLaddomat 21 Charging Unit
Laddomat 21 Charging Unit Part.No. 11 23 78 User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according
More information80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500
Release R.2.0 Uk 80-115 80-140 80-180 95-199 95-260 70-360 65-400 65-500 Installation User and Service Manual www.state-waterheaters.co.uk your installer Warning Read this manual carefully before first
More informationDescription of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
More informationHYDRAULIC DIAGRAM B O I L E R PELLETS PELLETS S W I M M I N G P O O L U N D E R F L O O R H E AT I N G 54 55
Identical operation of a boiler. Fire Potenza is transmitted through a heat exchanger to the water system, heating radiators, radiant floor, buffer tanks, and providing hot sanitary water ACQUA Fuonzionamento
More informationMedical Waste Incinerators
Medical Waste Incinerators by LDF Series of medical waste incinerator is developed from introduction of the Japanese medical waste incinerator technology, and organization of technical experts to solute
More informationSulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
More informationMANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
More informationLink-Up. Solid Fuel Association Guide to Central Heating. www.solidfuel.co.uk
Solid Fuel Association Guide to Central Heating Link-Up Combining solid fuel with other central heating technologies using various methods ranging from a simple link-up to a fully integrated thermal store
More informationSpecifications ECOIDRO boiler-stove
Specifications ECOIDRO boiler-stove Dear Sir or Madam, thank you for choosing our Ecoidro stove. Before using your stove, please read this booklet carefully: it explains how to get the most from all its
More informationFVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
More informationMH 3M & 4M. High pressure washers with hot benefits
MH 3M & 4M High pressure washers with hot benefits The EcoPower boiler provides high efficiency and lowest equivalent fuel consumption as certified by EUnited. All key functions placed for optimal ease-of-use.
More informationUsing waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling
Using waste heat with gas-fired steam humidifiers Condair GS Humidification and evaporative cooling Economical and ecological steam production with gas as primary energy. Gas-operated steam humidification
More informationNAVDURGA METAL INDUSTRIES (BHARAT)
A-1) Agni MDM (Mid Day Meal) Agni MDM (Mid Day Meal) Continuous & Batch feeding gasifier stove which has been designed especially for cooking of food in large quantity and which is very often provided
More informationWe have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
More informationAutomatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
More informationWhy use Tigerloop in fuel heating systems?
The Original Oil De-aerator Why use Tigerloop in fuel heating systems? Reliability New products are continually being developed in the modern oil heating industry in order to satisfy new laws and regulations
More informationKONRAD. Hybrid Fancoil Series
KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks
More informationOIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.
LOW PRESSURE OIL BURNERS CBW 50 CBW-150 OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS. CBW-50 CBW-150 40 100 kw 80 150 kw THIS TECHNICAL DOCUMENTATION
More informationPower consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
More informationChapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
More informationPOLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY
Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace Content 1. Technical overview cogeneration plant and heating network 2. Investment of the facility 3. Experiences
More informationHCE80/HCC80/HCE80R/HCC80R
HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA FEATURES Easy and fast installation because the new wiring design Pluggable terminals for fast wiring connection because clamp
More informationDIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
More informationITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
More informationA reasonable, new furnace (mid efficiency) has the following electrical requirements:
June 2007 Power Backup Systems for Your Home. As promised from a previous safety meeting, a couple of options to protect you home in the event of a power failure. These options are for the most serious,
More informationRESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
More informationR&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler
[N.2.1.1] R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler (Environment-Friendly, High-Efficiency Boiler Group) Takashi Murakawa, Yasuhiro Kotani, Kazuhiro Kamijo, Koichi Tsujimoto, Hiroshi
More informationDaikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
More informationBusiness Plan: Wood chip gasifier (Deliverable 5.2)
Public Energy Alternatives Business Plan: Wood chip gasifier (Deliverable 5.2) Period of publishing 6th reporting period Organization PP 20: Ylivieska Subregion TABLE OF CONTENTS 1 Characterics of deliverable
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationCondensate water pump with neutralisation system
Pumps for fuel oil and gas boiler Condensate water pump with neutralisation system SK9E/FP8E débit obtenu (l/h) caractéristriques selon la fréquence réglée performances avec une hauteur d aspiration de
More informationCondensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
More informationIt s time for H.E.R.O. Energy Saving Strategy for. Tunnel & Shuttle Kilns
Energy Saving Strategy for Tunnel & Shuttle Kilns SANITARY WARE 1 Introduction The application of the Kyoto protocol and the effects of the recent energy crisis, have highlighted just how important it
More informationSPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R8202395-02EN - Edition 02-21/04/2005
CUENOD Instantaneous Gas Water Heaters Storage Gas Water Heaters SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CELTIC RSc b R8202395-02EN - Edition 02-21/04/2005 Boilers Solar Panel 69214511 31 CELTIC
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationTANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
More informationAquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.
AquaFREE System Technical Catalogue Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.5/6)H(1/3) Specifications in this manual are subject to change without notice
More informationXFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications
The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications The XFE Soft Starter range provides a combination of competitive prices, flexible
More information