Update on an Ultra-Low GWP Refrigerant For Mobile Air Conditioning Applications
|
|
- Anna Neal
- 7 years ago
- Views:
Transcription
1 Update on an Ultra-Low GWP Refrigerant For Mobile Air Conditioning Applications Mark W. Spatz Honeywell Fluorine Products SAE 7 th Alternative Refrigerant Systems Symposium June 28 th 2006
2 Acknowledgements Valeo Climate Control Visteon Climate Control & Hyundai Colleagues at Honeywell 2
3 Introduction Due to a European Union directive on MAC refrigerants, there is a need to replace R-134a with a refrigerant that has a Global Warming Potential (GWP) of less than 150. CO2 (Carbon Dioxide, R-744) is a leading alternative, however system cost and service issues remain. HFC-152a - has similar properties to 134a with a low GWP of <150, but flammability is an issue. Work began in 2002 to identify a new, low GWP, non-flammable 134a replacement that is primarily targeted to the European auto industry that is facing the phase-out of R-134a beginning in
4 R-134a Replacement For Auto A/C No single component fluid met all the product requirements Fluid H: Azeotrope of: CF 3 CF=CH 2 (Major component) CF 3 I (Minor component) CF 3 CF=CH 2 : 1,1,1,2 Tetrafluoropropene Fluorocarbon Number: 1234yf New Material Not Commercially Produced CF 3 I: Trifluoromethyl iodide Known Material Produced In Small Quantities 4
5 Fluid H Physical Properties H 134a Boiling Point, T b -30 o C -26 o C Critical Point, T c 97 o C 102 o C P vap, kpa (5 o C) P vap, kpa (65 o C) Flammable No* No* GWP 100 < Pressure, bar Vapor Pressure 134a Fluid H Temperature, o C *ASHRAE Std. 34 & SAE J1657 Close Match To 134a Properties 5
6 Thermodynamic Properties of Fluid H Conditions (Assumptions): Evaporation Temperature Condensing Temperature Compressor Suction Compressor Isentropic Eff. 1.5 o C 65 o C 10 o C 65% Analysis Results: R-134a Fluid H Comments Suction Pressure (bar-abs) Condensing Pressure (bar-abs) Relative Mass Flow Relative Capacity Relative COP Minor property differences between 134a and Fluid H 6 Higher suction pressure - must change/adjust TXVs or higher superheat will result Slightly lower system pressure requirements, controls based on pressure must be adjusted Higher pressure drop but also better heat exchanger flow distribution. Optimization of hxs Slightly lower cycle capacity & COP but optimized heat exchangers likely will reduce or eliminate this deficit
7 Performance Evaluation Summary 120% Since the beginning of this year numerous evaluations have been performed. y About 8 sets of either vehicle wind tunnel or bench tests at OEMs & Tier 1 s (summary of bench test data show here). Results show close performance to R-134a considering most do not involve any changes. Most recent tests reveal potential to match or exceed R-134a with optimized components. Relative Capacity to R-134a Relative COP to R-134a 100% 80% 60% 40% 20% 0% Ambient Temp ( o C) 140% 120% 100% 80% 60% 40% Thermo CTS Supplier A Supplier B OEM B Supplier C Thermo CTS Supplier A Supplier B OEM B Supplier C 20% 7 0% Ambient Temp ( o C)
8 System Stability Fluid H was developed to quickly breakdown in the atmosphere to significantly reduce any direct impact on global warming Tests in sealed tubes and in systems have been conducted with results demonstrating stability to 160 o C y These results have previously been presented. Further testing is in progress to quantify the reliable operating envelope of this refrigerant. y It should be noted that R-134a is an extremely stable molecule and Fluid H is unlikely to be as stable. y However the industry has successfully used R-12 for many years and its stability is also less than R-134a. 8
9 Material Compatibility and Permeability Commonly used material Hose materials y Butyl rubber y Chlorinated butyl rubber (CIIR) y PA materials (Nylon 6 or 6.6) O-Rings/Sealing y HNBR y EPDM y Neoprene or Chloroprene Other y Desiccant (e.g. XH7, XH9) y Membrane (e.g. Kapron) y Compressor materials (e.g. shaft seals, coatings) In-house Compatibility Tests y Commonly used materials in laboratory tests May to August 2006 Supplier Compatibility and Permeation Tests y External tests at material suppliers May to November 2006 y Additional Tests at systems suppliers and OEMs 9
10 Material Compatibility and Permeability Test condition: 50 C for 1 week Percent change Material Volume Wt NBR O-ring -0.4± ±0.4 Shaft Seal - HNBR 8.2± ±3.7 HNBR O-rings 3.6± ±0.6 Green Neoprene O-rings 1.2± ± C for 2 weeks Percent change in properties Material Volume Wt Hardness NBR O-ring 4.2± ± ±3.0 Parker HNBR platen 6.4± ± ±1.1 General Guidelines -5/+20 % -10/+20% +/- 10% No significant issues seen in initial compatibility tests 10
11 Viscosity of Refrigerant/Oil Mixtures Lines generated from Henderson's model for ISO 68 PAG and R134a [1]. 100% monocapped PAG oil, 70 cst at 40 C 90.0% monocapped PAG oil, 10.0% Fluid H 74.2% monocapped PAG oil, 25.8% Fluid H 50.5% monocapped PAG oil, 49.5% Fluid H Note that Henderson's model is valid from 0 to 30% R134a. Therefore, no line can be drawn to compare to viscosities collected from the 50.5% oil 49.5% Fluid H mixture. Viscosity (cp) Temperature ( C) Slightly higher viscosity of Fluid H/PAG mixtures 11
12 Honeywell / Valeo Demonstration Vehicle Converted a 2006 VW Jetta a/c system to Fluid H GLI version with 2.0 liter turbocharged engine. Modification made: y Adapted expansion valve for Fluid H. Tests ran at Valeo in France: y System test bench. y Vehicle wind tunnel test of similar vehicle (same engine and a/c system). 12
13 Test Conditions Vehicle cool down procedure used: Test conditions : 45 C & 40% RH with sun load of 1000 W/m 2-30 minutes : 40 km/h 3rd gear - 30 minutes : IDLE - 20 minutes : 90 km/h 5th gear Aerothermal test bench: two sets of conditions were used A/C loop sizing points Evap Blower Evap T ( C) Evap RH (%) Car speed Cond air speed (m/s) Cond T ( C) Comp (rpm) Air T target ( C) Sizing 40 km/h 2, Max Min IDLE 0 km/h 1, Cool down representative test points Evap Blower Evap T ( C) Evap RH (%) Car speed Cond air speed (m/s) Cond T ( C) Comp (rpm) Air T target ( C) Pt n 1 46,5 15 Pt n 2 Max km/h 2, Pt n 3 recirculation Min Pt n 4 (1,2) mode 1, km/h Pt n 4 (1,6) 1, R-134a : standard production system; Fluid H: same system with adapted TXV 13
14 Vehicle Cool Down Front panel (Fluid H) Front panel (R-134a) Breath level (FluidH) Breath level (R-134a) 45 Temperature ( C) km/h (3rd gear) 30' IDLE 30' 90 km/h (5th gear) 20' Time (s) 14
15 Bench Test Results Air T Fluid H Air T R-134a COP fluid H COP R-134a Air blown Temperature ( C) Pt n 1 Pt n 2 Pt n 3 Pt n 4 (1,2 ) Pt n 4 (1,6) Sizing IDLE 4,0 3,8 3,6 3,4 3,2 3,0 2,8 2,6 2,4 2,2 2,0 1,8 1,6 1,4 1,2 1,0 0,8 0,6 0,4 0,2 0,0 COP (-) 15
16 Visteon/Hyundai System Development Fluid H integrated into Visteon CAE tools y Used to design components that take full advantage of Fluid H characteristics Extensive refrigerant sub-system testing y Validated CAE models y Fully characterized performance attributes of H Designed new components using R134a subcomponent building blocks (tubes, plates, fins, hoses, etc) 16
17 Visteon/Hyundai Vehicle Development Production Vehicle y 2006 Hyundai Accent Production R134a System y VS16 variable swashplate compressor y 45mm plate-fin evaporator y 16mm condenser with integrated receiver drier y TXV Vehicle Configurations Evaluated y Production R134a y Fluid H as pure drop-in y Modified hardware #1 minor modifications y Modified hardware #2 (Test vehicle shown here) 8 Production compressor, pulley ratio, engine cooling fan 8 Other refrigerant system components modified to take advantage of H properties (same package & core depth as production) 17
18 Wind Tunnel Results 60 Discharge air (C) R134a Pure drop-in H Modification1 H Time (min) Modification 2 (demonstration vehicle) not yet tested in wind tunnel 18
19 Conclusions Development work continues on a very low GWP non-flammable refrigerant. Evaluation results are promising. System and Vehicle Test Results y Initial drop in tests were encouraging but more recent testing of systems that have had modest modifications show very close and even better performance to that of R-134a y Any reduction in capacity seen in drop-in tests was shown to be overcome by slight modifications to the system: 8 Change expansion device, modify suction lines, and/or modify heat exchanger flow paths. Investigation of material compatibility, stability, toxicology, and environmental impact continues. Results to date have not revealed any major obstacles to the successful development of this refrigerant. This refrigerant has the potential to be a more cost-effective replacement than other R-134a alternatives currently in development. DISCLAIMER Although all statements and information contained herein are believed to be accurate and reliable, they are presented without guarantee or warranty of any kind, expressed or implied. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and the user assumes all risks and liability for use of the information and results obtained. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. The user should not assume that all toxicity data and safety measures are indicated herein or that other measures may not be required. 19
Update on a Low GWP Refrigerant: Fluid H
Update on a Low GWP Refrigerant: Fluid H Mark W. Spatz Global Leader Refrigerant Technology Honeywell Fluorine Products SAE 2007 Alternatives Refrigerant Systems Symposium July 17-19, 2007 1 Agenda Material
More informationLow-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta
Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications Samuel F Yana Motta Refrigerants for Stationary Applications HONEYWELL CONFIDENTIAL N Series L Series Current Product Reduced GWP
More informationA/C System Control Strategies for Major Refrigerant Options
A/C System Control Strategies for Major Refrigerant Options J.Benouali, S.Karl, C.Petitjean Final June 11th, 28 ntroduction AR selection and then? 1 years to come to AR selection 1 years ago: 1st Phoenix
More informationLow GWP Replacements for R404A in Commercial Refrigeration Applications
Low GWP Replacements for R404A in Commercial Refrigeration Applications Samuel YANA MOTTA, Mark SPATZ Honeywell International, 20 Peabody Street, Buffalo, NY 14210, Samuel.YanaMotta@honeywell.com Abstract
More informationEvaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications
Evaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications Thomas J. Leck DuPont Fluorochemicals Wilmington, Delaware 3rd IIR Conference on Thermophysical Properties and
More informationEnvironmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems William M. Corcoran, George Rusch, Mark W. Spatz, and Tim Vink AlliedSignal, Inc. ABSTRACT
More informationR407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C
GUIDELINES FOR UTILIZATION OF R407C 2009 Tecumseh Products Company. All rights reserved. Page 1 of 6 After many years of testing and investigation, R407C is recognized as a suitable alternative refrigerant
More informationCommercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:
PART 1: CO 2 Commercial refrigeration has been in the environmental spotlight for more than a decade, especially as leakage studies have revealed the true effects of hydrofluorocarbon (HFC) emissions.
More informationRefrigerant System for Vehicle Air- Conditioning NISSAN / ZEXEL. Phoenix Alternate Refrigerant Forum June,28----July,1 Phoenix, AZ
A CO 2 Refrigerant System for Vehicle Air- Conditioning NISSAN / ZEXEL Phoenix Alternate Refrigerant Forum June,28----July, Phoenix, AZ Outline ZEXEL Activities for Environment Protection 99 Model of CO
More informationTEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #31 System Drop-in Test of Refrigerant R-32 in Split Air-conditioning
More informationPG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.
International Journal of Emerging Trends in Engineering and Development Issue 3, Vol. (January 23) EFFECT OF SUB COOLING AND SUPERHEATING ON VAPOUR COMPRESSION REFRIGERATION SYSTEMS USING 22 ALTERNATIVE
More informationTHE REPLACEMENT OF R-22
ENGLISH TRANSLATION OF ARTICLE IN FRIO-CALOR AIRE ACONDICIONDAO BY GAS-SERVEI, S.A JUNE 2010 THE REPLACEMENT OF R-22 Courtesy of D. Lluis Giralt Lopez (Chemical Engineering Industrial) Gas Technical Department
More informationrefrigerants DuPont Suva 134a (HFC-134a) for Mobile Air Conditioning Technical Information Introduction Transition to HFC-134a
Technical Information DuPont Suva refrigerants Note: This publication supersedes Bulletin ART-12. ART-27 DuPont Suva 134a (HFC-134a) for Mobile Air Conditioning Introduction In the past almost all mobile
More informationRepair, Retrofit, or Replace Choices for Servicing R-22 Equipment
Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment Brett Van Horn Market Manager HVAC Arkema Inc. 900 First Ave King of Prussia, PA 19406 Topics Covered Today R-22 Phase-out EPA Allowances
More informationHCFC-22 Retrofits. There has been increased emphasis on retrofitting R-22
HCFC-22 Retrofits A c l o s e l o o k a t t h e r e f r i g e r a n t / l u b r i c a n t i n t e r a c t i o n s. B y S a m u e l F. Y a n a M o t t a, E l i z a b e t D. V e r a B e c e r r a, R o n
More informationA/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
More informationA Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures
R2-1 A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures W. Vance Payne and Piotr A. Domanski National Institute of Standards and Technology Building Environment
More informationInformation for HFO-1234yf Automotive Plant and Service Shop Implementation
Information for HFO-1234yf Automotive Plant and Service Shop Implementation Mary Koban, Automotive Sr Technical Engineer DuPont Fluoroproducts, Wilmington,DE 2 Agenda HFO-1234yf Properties Flammability
More informationPart A: Fluid properties
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material on HFC for management: HFC Workshop, technical 2015 issues Bangkok, 20 and 21 April 2015 FACT SHEET 15 Glossary of terms and technical
More informationHFO-1234yf. A Low GWP Refrigerant For MAC. Honeywell / DuPont Joint Collaboration. 13-14 February, 2008
HFO-1234yf A Low GWP Refrigerant For MAC Honeywell / DuPont Joint Collaboration Mark Spatz Honeywell Barbara Minor DuPont 13-14 February, 2008 VDA Alternative Refrigerant Winter Meeting 2008 Saalfelden,
More informationRS-44 (R424A) : Q & A
RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,
More informationScroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss.
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss.com Danfoss Commercial Compressors Leading compressor R&D and manufacturing
More informationPerformance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems Dr. Charles C. Allgood 1, C. Curtis Lawson 2 1 DuPont Fluorochemicals, Wilmington, DE, USA E-mail: Charles.C.Allgood-1@usa.dupont.com
More informationA Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential
International Journal of Scientific and Research Publications, Volume 2, Issue 9, September 2012 1 A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of
More informationLow Global Warming Fluids for Replacement of HFC-245fa and HFC-134a in ORC Applications
Low Global Warming Fluids for Replacement of HFC-245fa and HFC-134a in ORC Applications *Honeywell, 20 Peabody St., Buffalo, NY USA 14210 e-mail: gary.zyhowski@honeywell.com Gary Zyhowski* and Andrew Brown
More informationTEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #44 System Drop-in Tests of Refrigerant R-32 in Single Packaged
More informationVolkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
More informationDevelopment of CO 2 A/C System
Development of CO 2 A/C System CK s s Aiming of CO 2 Air Conditioning System Aiming CK develops two kinds of CO 2 air conditioning systems. These are the one for the vehicles of a source of the present
More informationRS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm)
RS-52 (R428A) COMPOSITION % HFC 125 77.5 HFC 143a 20.0 R600a 1.9 R290 0.6 HCFC replacement Temperature glide R22, 502 & interim blends Approximately 0.8 o C Drop-in or long term Both Lubricant MO/AB/POE
More informationRS-24 (R426A): Q & A
RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24
More informationAir Conditioning System
Air Conditioning System 1 Chonan Technical Service Training Center Chonan Technical Service Training Center 2 Objectives To understand the components of air conditioning system. To understand the control
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationSubject: 2005 Air Conditioning Service Guidelines
Date: June 27, 2005 Bulletin Number: 05D-J-114 To: DDG Headquarters and Branches and Jobbers Category: Service From: Steve Sigg, Product Service and Training Line(s): 10 and 15 Subject: 2005 Air Conditioning
More informationDEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA joost.j.brasz@carrier.utc.com I K Smith and N Stosic
More informationSERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS 2009 Tecumseh Products Company. All rights reserved. Page 1 of 8 Refrigerant R22 is widely used for residential and commercial air conditioning, as
More informationAIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION
AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION Tony Thorne Manager of Electrical Engineering Index Sensors and Controls, Stanwood, WA 98292 USA ABSTRACT Air conditioning
More informationRefrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
More informationSystem Diagnosis. Proper vehicle diagnosis requires a plan before you start
System Diagnosis Proper vehicle diagnosis requires a plan before you start Following a set procedure to base your troubleshooting on will help you find the root cause of a problem and prevent unnecessary
More informationPerformance of R-438A in R-22 Refrigeration and Air Conditioning Systems
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 21 Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems
More informationNews in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
More information2.1 The performance of bus air conditioning system is evaluated in the following operating conditions
1.0 Scope:- This test procedure is applicable for testing the Air Conditioning system performance at hot ambient and very hot ambient condition on intracity urban bus in a climatic hot chamber. This procedure
More information01-3 6820-11 6820-11 AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON 2010.01
682011 013 GENERAL 1. SPECIFICATIONS 682011 014 682011 2. REPAIR INSTRUCTIONS 1) Precautions for Working with R134a R12 refrigerant and R134a refrigerant are not compatible. These refrigerants must never
More informationAutomobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
More informationVariable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
More informationR-152a Refrigeration System for Mobile Air Conditioning
SAE TECNICAL PAPER SERIES 2003-01-0731 R-152a Refrigeration System for Mobile Air Conditioning James A. Baker, Mahmoud Ghodbane, Lawrence P. Scherer and Prasad S. Kadle Delphi William R. ill General Motors
More informationRusty Walker, Corporate Trainer Hill PHOENIX
Refrigeration 101 Rusty Walker, Corporate Trainer Hill PHOENIX Compressor Basic Refrigeration Cycle Evaporator Condenser / Receiver Expansion Device Vapor Compression Cycle Cooling by the removal of heat
More informationON-VEHICLE INSPECTION
Sight Glass I11244 ONVEHICLE INSPECTION 1. INSPECT REFRIGERANT VOLUME Observe the sight glass on the liquid tube. AC3 AC22F05 Test conditions: Running engine at 1,500 rpm Blower speed control switch: HI
More informationAir Conditioning 101. STN Presentation AC101
Air Conditioning 101 What is Refrigeration? Refrigeration is Cooling by the Removal of Heat Heat is Measured In BTU s A BTU is a British Thermal Unit It is the Amount of Heat to Raise One Pound of Water,
More informationHeat Recovery In Retail Refrigeration
This article was published in ASHRAE Journal, February 2010. Copyright 2010 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Posted at www.ashrae.org. This article may not
More informationTSB #: 74 Date: 9/7/2013 HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS
HOLDEN VE/WM HVAC & A/C DIAGNOSTIC HINTS TSB #: 74 Date: 9/7/2013 Initial Once Read: In this technical bulletin we have listed diagnostic advice relating to the Holden VE/WM HVAC & A/C system. This information
More informationPurpose of Refrigeration
Refrigeration Outline Purpose of refrigeration Examples and applications Choice of coolant and refrigerants Phase diagram of water and CO 2 Vapor compression refrigeration system Pressure enthalpy diagram
More informationMACS Recommended Service Procedures
MACS Recommended Service Procedures Initial Customer Contact It is important to obtain information from the customer identifying the problem and any previous servicing history prior to attempting repair
More informationANNEX 1. Analysis of scientific literature
ANNEX 1 Analysis of scientific literature Ref. Authors Title Source [McE98] R.P McEnaney, D.E Boewe, J.M Yin, Y.C Park, C.W Bullard, P.S Hrnjak Experimental comparison of mobile A/C systems when operated
More informationTHEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A
THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A Jignesh K. Vaghela Assistant Professor, Mechanical Engineering Department, SVMIT, Bharuch-392001, (India) ABSTRACT
More informationPressure sensors for automotive HVAC systems
Pressure sensors for automotive HVAC systems Tom Kwa, PhD CTO DunAn Sensing LLC Automotive Sensor and Electronics Expo 20-21 May 2015 Detroit, Michigan 1 Outline The need for automotive A/C and the need
More informationIV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
More informationRefrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate CFC Technologies, Inc. does not advocate the HCFC wholesale
More informationDaikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
More informationTheoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning
More informationSilicagel-water adsorption cooling prototype system for mobile air conditioning
Silicagel-water adsorption cooling prototype system for mobile air conditioning R. de Boer S.F. Smeding S. Mola Paper to be presented at the Heat Powered Cycles Conference 09 Berlin, 7 to 9 September 2009
More informationUNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
More informationCooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
More informationREFRIGERANT REFERENCE GUIDE
REFRIGERANT REFERENCE GUIDE WORLWIDE REFRIGERANT SUPPLIER 2004 FOURTH EDITION 2004 DISCLAIMER This publication is designed to provide accurate and authoritative information. It is not to be construed as
More informationAdvanced Engine Cooling Systems for Vehicle Application
Advanced Engine Cooling Systems for Vehicle Application Italo LONGO EMEA Engine Systems Unit Responsible April 2015 Italo Longo Engine Systems Unit Responsible EDUCATION Mechanical Engineering Master Degree
More informationCooling system components, servicing
19-1 Cooling system components, servicing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate protection, cover the cap
More informationFlushing and Cleaning the A/C System
Flushing and Cleaning the A/C System Once an AC system has been contaminated or has suffered a failure, the most important part of the AC service to restore the cooling performance to the system = FLUSHING
More informationCC145. Air Conditioning System. Operation Manual. CC145 Compact Cooler 4/2013 P.N. 10000034A
Air Conditioning System Operation Manual CC145 Compact Cooler 4/2013 P.N. 10000034A To receive the best performance from the air conditioning system, we suggest carefully reading this manual before operating
More informationMAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )
MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing ) The Concept Maximum Heat Load Temperature Testing is a powerful air-conditioning diagnostic and evaluation technique. It is also
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationHVAC-02, Air Conditioning Troubleshooting and Repair
HVAC-02, Air Conditioning Troubleshooting and Introduction Since I'm constantly receiving questions on 944 air conditioning systems, I figured it's time to come up with come helpful troubleshooting tips.
More informationRefrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions
Refrigerant Changeover Guidelines R-22 to R-407C Leading the Industry with Environmentally Responsible Refrigerant Solutions Copeland does not CFC advocate the wholesale changeover of HCFC HCFC refrigerants
More informationA car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine
A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine G Vicatos J Gryzagoridis S Wang Department of Mechanical Engineering,
More informationHFO-1234yf. A Low GWP Refrigerant For MAC. Honeywell / DuPont Joint Collaboration
HFO-1234yf A Low GWP Refrigerant For MAC Honeywell / DuPont Joint Collaboration Mark Spatz Honeywell Barbara Minor DuPont SAE World Congress Detroit, Michigan April 14-17, 2008 1 Background DuPont And
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More informationCommercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications
Commercial CO2 Refrigeration Systems Guide for Subcritical and Transcritical CO2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section 1.
More informationLesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1
Lesson Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications Version ME, IIT Kharagpur The objectives of this lecture are to discuss. Performance aspects of SSS cycle and
More informationScroll Compressor Development for Air-Source Heat Pump Water Heater Applications
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications
More informationAn Assessment of Alternative Refrigerants for Automotive Applications based on Environmental Impact
An Assessment of Alternative Refrigerants for Automotive Applications based on Environmental Impact V. Sumantran Bahram Khalighi Kevin Saka General Motors R&D Center Steve Fischer Oak Ridge National Laboratory
More informationRegency TAFE, SA. An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump. July 2008. Prepared by
Regency TAFE, SA An evaluation of the effects of PermaFrost treatment on a Fujitsu Heat Pump July 2008 Prepared by Andrew Pang Andrew Pang & Associates Pty Ltd Phone: 0438 188 180 Facsimile: 9331 0898
More informationInverter and programmable controls in heat pump applications
Inverter and programmable controls in heat pump applications Biagio Lamanna Application Competence Centre Manager Product Development Process CAREL INDUSTRIES Srl 3rd EHPA European Heat Pump Forum Brussels
More informationTECHNICAL ANNEX. Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures. November 2014
TECHNICAL ANNEX Alternatives to HCFCs/HFCs in unitary air conditioning equipment at high ambient temperatures November 2014 Authors: Bastian Zeiger, Barbara Gschrey, Winfried Schwarz Öko-Recherche, Frankfurt/Main,
More informationTHERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
More informationNew Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
More informationImpacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
More informationRefrigeration and Air Conditioning with Reduced Environmental Impact
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Refrigeration and Air Conditioning with Reduced Environmental Impact D.
More informationService & Parts Manual
Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow
More informationHVAC SYSTEM (HEATER, VENTILATOR, AND A/C)
HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core
More informationMohan Chandrasekharan #1
International Journal of Students Research in Technology & Management Exergy Analysis of Vapor Compression Refrigeration System Using R12 and R134a as Refrigerants Mohan Chandrasekharan #1 # Department
More informationInformation on New Refrigerant (R-1234yf) for A/C Service
Information on New Refrigerant (R-1234yf) for A/C Service 2013 Cadillac ATS, XTS This bulletin is being revised to include procurement and labeling information for recovery cylinders to be used with GE-50957-Contaminated
More informationGround-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29
Ground-breaking conversion of critical Data Room WaterChiller from R22 to R422D / MO29 A refrigerant retrofit project, involving the conversion of a large Data Room cooling system from R22 to R422D (DuPont
More informationDESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE
DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE Md Shahid Imam, Dr.M.Shameer Basha, Dr.Md.Azizuddin, Dr. K.Vijaya Kumar Reddy 4 M.Tech HVAC II Yr, Royal Institute of Technology & Science Chevella R.R Dist
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationAUTOMOTIVE AIR-CONDITIONING SYSTEMS HISTORICAL DEVELOPMENTS, THE STATE OF TECHNOLOGY AND FUTURE TRENDS. R.K. Shah
Proceedings of the 3 rd BSME-ASME International Conference on Thermal Engineering, 20-22 December 2006, Dhaka, Bangladesh AUTOMOTIVE AIR-CONDITIONING SYSTEMS HISTORICAL DEVELOPMENTS, THE STATE OF TECHNOLOGY
More informationCLIMATE CONTROL SYSTEM OPERATION, DIAGNOSIS, AND REPAIR
CLIMATE CONTROL SYSTEM OPERATION, DIAGNOSIS, AND REPAIR Welcome to Climate Control System Operation, Diagnosis, and Repair, which is the final training course in the Electrical training sequence. When
More informationExperimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering Experimental Analysis of an Automotive Air Conditioning System With Two-Phase
More informationStructure of this presentation
Michael Matthias Structure of this presentation The copying, distribution and utilization of this document as well as the communication of its contents to others without expressed authorization is prohibited.
More informationTechnical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
More informationWhy and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
More informationCPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
More informationRecommended Compressor Installation Practices
ASPEN COMPRESSOR, LLC Phone: 508.481.5058 Fax: 508.480.0328 Email:info@aspencompressor.com Website: www.aspencompressor.com Recommended Compressor Installation Practices 1. COMPRESSOR SELECTION AND USE
More information